Home

DA3 USER MANUAL

image

Contents

1. DA3 USER MANUAL AR Technology Automated Transactions Bellis Technology INTELLIGENCE IM VALIDATION T INTELLIGENCE IM VALIDATIDM U0 1WIiELLIGEWLE IN VALIBATIURM MTELLIGEMCE IN VALIDATION Copyright Innovative Technology GA339 4 DA3 User Manual 2 CONTENTS 1 Introduction 3 2 Power requirements 5 3 General description 6 4 Software installation 1 5 Connecting the DA3 to a PC 8 6 Programming the DA3 10 6 1 Adding datasets to the dataset library 10 6 2 Adding firmware to the firmware library 11 6 3 Storing files on the DA3 12 6 4 Tagging files for override 13 6 5 Importing and exporting set up files 13 6 6 Summary info 14 6 7 Memory card functions 14 6 8 VPS utilities 15 1 Using the DA3 16 7 1 Connecting a validator to the DA3 16 7 2 BNV match download 16 7 3 BNV override download 17 7 4 Set BNV to check mode 17 1 5 Serial comm monitor 18 7 6 Collect note data 18 1 1 Copy A to DA3 18 7 8 Copy DA3 to A 18 7 9 Copy A to B 19 Appendix 1 Error codes 20 Appendix 2 Supported note validators 20 Copyright Innovative Technology GA339 4 DA3 User Manual 1 INTRODUCTION This manual describes the operation of the DA3 Validator Programming System programmed with firmware version VPS1001000000000 or later using the VPS software version 1 0 7 or later If you do not understand any part of this manual please contact the factory for assistance contact details are below In this way we may continue
2. DA3 from USB host connector and power connector Insert the new card into memory card slot A and apply power either through the power connector or the host connector If the card is not formatted the centre button will light red and no further operation will be possible Remove and re apply the power the memory card will then be formatted Copyright Innovative Technology GA339 4 DAS User Manual 6 8 VPS UTILITIES Using the VPS Utilities screen you can update the operational firmware of your DA3 Innovative Technology Ltd Validator Programming System VPS Version 1 0 7 YPS Operational Firmware update utility Connected VPS Update VPS Firmware YPS Hardware connected Open VPS Firmware fe Update VPS Firmware Serial Number 1010 Firmware Version P51001 000000000 Loaded VPS Firmware File VPS1001000000000 vps Connected Device Dataset Library Firmware Library I Memory Card J Click the button to browse for the firmware file and then click the Update VPS Firmware The DA3 operational firmware will be updated DO NOT disconnect the DA3 while the firmware upgrade is taking place Doing so could permanently damage the DA3 Copyright Innovative Technology GA339 4 DAS User Manual 7 USING THE DAS 4 1 CONNECTING A VALIDATOR TO THE DAS3 Connect the validator to the DAS via the supplied 16way ribbon cable Power must be applied to the DA3 via a se
3. to improve our product This document is intended for those who will e Program the DA3 e Program validators using the DA3 Innovative Technology Ltd has a policy of continual product improvement As a result the products supplied may vary from the specification described here The ITL Logo is an international registered trademark and is the property of Innovative Technology Limited Innovative Technology has a number of European and International Patents and Patents Pending protecting this product If you require further details please contact the factory Innovative Technology is not responsible for any loss harm or damage caused by the installation and use of this product This does not affect your local statutory rights If in doubt please contact Innovative Technology for details of any changes Kit Components The DA3 Kit comprises of the following DA3 Programming Unit USB A to USB B cable DA3 to ITL Note Validator Cable Support CD MAIN HEADQUARTERS Innovative Technology Ltd Derker Street Oldham England OL1 4EQ Tel 44 161 626 9999 Fax 44 161 620 2090 E mail support innovative technology co uk Web site www innovative technology co uk Copyright Innovative Technology GA339 4 DAS User Manual GROUP AR Technology INTELLIGENCE IN VALIDATION Automated Transactions INTELLIGENCE IM VALIDATION Bellis Technology INTELLIGENCE IN VALIDATION Copyright Innovative Technology E
4. to save them to a DA3 Copyright Innovative Technology P GA339 4 DAS3 User Manual 6 6 SUMMARY INFORMATION In the Connected Device window click on the Summary Information button to run a report of all the files stored on the connected DA3 6 7 MEMORY CARD FUNCTIONS Within the VPS software you can copy files to and from Memory card A Memory card B and the DA3 memory Also delete files from Memory card A Memory card B and the DA3 memory Innovative Technology Ltd Validator Programming System VPS Version 1 0 7 CARD A YPS MEMORY CARD B Fitted Fitted Fitted Memory size 8M byte Memory size 8M byte Memory size 8M byte Data Files 38 Data Files 38 Memory Used 4832K bytes Memory Used 4832K bytes NV 216 BIN NV 216 BIN NV8 215 BIN NVS 215 BIN NYV10 313 BIN NV10 313 BIN NV3 313 BIN NV3 313 BIN NV 215 CCT NV 216 CCT NV8 216 CCT NV8 216 CCT NV3 319 CCT NV3 319 CCT NY10 313 CCT NV10 313 CCT NV 216 MDB NV 216 MDB NV8 216 MDB NV8 216 MDB NV3 319 MDB NV3 319 MDB N 10 319 MDB NY10 319 MDB NV 216 SI2 NV 216 SI2 NV8 215 SI2 NYS 215 SI2 NV3 313 SI2 NV3 313 SI2 NYV10 313 512 NV10 313 SI2 NV 215 SIO NV 216 SIO NV8 216 SIO NV6 216 SIO NV3 319 510 NV3 319 SIO v lt lt gt gt Erase Copy Card A to DAS Erase Copy DA3 to Card A Connected Device Ji Dataset Library l Firmware Library J A YPS Lltilites NOTE New memory cards may need to be formatted To format cards disconnect the
5. 1 2007 RJS First draft 22 01 2007 RJS Second draft reorganised chapters Issue C 08 02 2007 RJS Third draft addition of memory card formatting Issue 1 13 02 2007 RJS Initial release 20 02 2007 RJS Updated Appendix 2 Issue 3 19 03 2007 RJS Updated Appendix 2 Issue 4 17 11 2008 RJS Updated Appendix 2 Innovative Technology has a number of European and International Patents and Patents Pending protecting this product If you require further details please contact the factory Smiley and the ITL Logo are international registered trademarks and they are the property of Innovative Technology Limited Innovative Technology is not responsible for any loss harm or damage caused by the installation and use of this product This does not affect your local statutory rights If in doubt please contact Innovative Technology for details of any changes In line with continued product development Innovative Technology Ltd reserves the right to change specifications without prior notice The data used in this document may be used as a guideline only Copyright Innovative Technology GA339 4
6. KI 1 510 20 1 5 10 20 GBPO3 SHEUNITED KI 5 10 20 124 GBPOB 906 SISUNITED Kl 5110 20 5 10 20 GBPOS 903 SHEUNITED KI 1 5 10 20 1 5 10 20 GBP14 901 SHEUNITED Kl 5 10 20 510 20 GBP21 SFS UNITED KI 510 20 2 GBP09 S UNITED KI 5 10 f GBP27 704 SHEUNITED KI 510 20 5 10 20 GBP28 702 Mi lt gt Loaded Firmware Binary SSP Parallel Pulse ccTalk SSP Parallel Pulse MDB SSP Parallel Pulse Simple serial 2 SSP Parallel Pulse Simple serial SSP Parallel Pulse Update Device Summary Infomation L Connected Device Dataset Library Fimware Library Memo Card VPS Utiites Once the required files are tagged click the Update Device button to save the settings to the DA3 memory 6 5 IMPORTING AND EXPORTING SET UP FILES The files contained within the Connected Device window can be exported into a DA3 file Another user can then import this file All dataset and firmware files will be imported and the appropriate files will still be tagged This function is useful to ensure other DAS users have the same files and settings stored To export a setup file click the Export Setup File button type in a file name and select the location to store the file then click the Save button To import a setup file click the Import Setup File button locate the file you wish to import and click the Open button Once the files are imported you must click the Update Device button
7. MAIL CONTACT BRAZIL suporte bellis technology com br CHINA support innovative technology co uk COLUMBIA support automated transactions net GERMANY support automated transactions de ENGLAND support innovative technology co uk SPAIN soporte automated transactions es UNITED STATES OF AMERICA supportusa bellis technology com REST OF THE WORLD sales innovative technology co uk GA339 4 DA3 User Manual 2 POWER REQUIREMENTS When programming the DA3 using the VPS software power is taken from the USB bus no external power supply is required When programming validators or using the DA3 card copy functions power must be applied via the host machine or from a separate 12V DC 1500mA power supply Copyright Innovative Technology GA339 4 DA3 User Manual 3 GENERAL DESCRIPTION The DAS is a programming system designed to enable the programming of ITL Bank Note Validators in the field without the use of a PC see Appendix 2 for supported products Many dataset and firmware files for different validator models can be stored on the DA3 Once the DA3 has been programmed the user can e Update the existing software within a validator using the BNV Match Download Function For example a validator already programmed for UK notes can be updated with the latest available UK dataset automatically All custom settings will remain the same i e the number of pulses set and the special interface within the validator wi
8. button e Connect the BNV to the DA3 as described in chapter 7 1 and apply power either from the host machine or from a separate 12V power supply e Press the Mode Select button repeatedly until the blue SET BNV TO CHECK MODE LED is illuminated The RUN button will pulse green to indicate that this function is available e Press the Centre RUN button e The centre RUN button will change colour to pulsing blue and the DATA CONNECTION LED with flash as data is transferred to and from the DAS If communications can not be established the centre RUN button will change colour to pulsing red and the blue SET BNV TO CHECK MODE LED will flash a code as described in Appendix 1 e When notes are inserted and accepted the Mode Indicator LED will switch off a number of times according to which channel the note has been credited For example if a note from channel 3 has been inserted the Mode Indicator LED will switch off and back on again 3 times Copyright Innovative Technology GA339 4 DA3 User Manual 7 5 SERIAL COMM MONITOR This function is not yet implemented The centre RUN button will not illuminate to indicate that this function is not available 7 6 COLLECT NOTE DATA This function is not yet implemented The centre RUN button will not illuminate to indicate that this function is not available 7 7 COPY A TO DA3 This function copies the contents of the memory card in slot A to the internal memory of the DAS All files stored
9. e Press the Mode Select button repeatedly until the blue BNV OVERRIDE DOWNLOAD LED is illuminated The RUN button will pulse green to indicate that this function is available e Press the Centre RUN button e The centre RUN button will change colour to pulsing blue and the Mode Indicator LEDs will rotate back and forth as communication is established The DATA CONNECTION LED with flicker as data is transferred to and from the DAS If there are no files tagged for the connected BNV the centre RUN button will change colour to pulsing red and the blue BNV OVERRIDE DOWNLOAD LED will flash a code as described in Appendix 1 e The Mode Indicator LED s will rotate in an anti clockwise direction while the firmware is updated e Once the firmware update is complete the Mode Indicator LED s will rotate in a clockwise direction as the dataset is updated e When the firmware and dataset are successfully updated the centre RUN button will change to a pulsing green light and the BNV will reset e If necessary set the BNV dipswitches to their required positions before re connecting the BNV to the host machine 7 4 SET BNV TO CHECK MODE This function enables the validator to accept notes so that testing can take place outside of the host machine e Set the BNV to SSP mode as described in the BNV product manual Depending on the BNV model this will be either by setting the dipswitches as shown on the product label or by pressing a download reset
10. ell sse yt Drag beste ai enpetang A warning will be displayed informing you rs ee eer eae that the driver has not passed Windows a vta em eee Logo testing conlact the hardware vendo For sofbeare that har passed Widows Logo beating Click Continue Anyway Euntes TOP aon Windows will then install the necessary software DornplLatnag tho Found Hew Hardware Wr and po When the software has been installed you Will see this screen Click Finish J Found New Hardware x Your new hardware is installed and ready to use A Found New Hardware message will be displayed when the installation is complete This message will close automatically Copyright Innovative Technology GA339 4 DA3 User Manual 6 PROGRAMMING THE DA3 To use the DA3 you must first save the required datasets and firmware files to the DA3 s internal memory You can do this by either using the VPS Software this chapter or copying data from a pre programmed memory card see Chapter 7 7 To use the VPS software you must select the files you wish to store on the DA3 from the dataset library and the firmware library When first used the libraries will be empty you will need to add files as detailed below You will also need to add new files when re programming the DA3 with updated datasets or firmware 6 1 ADDING DATASETS TO THE DATASET LIBRARY Select the Dataset Library tab The screen will show all the dataset files that are c
11. ght Innovative Technology GA339 4 DA3 User Manual 6 3 STORING FILES ON THE DAS In the dataset and firmware libraries select the files you wish to save to the DAS Holding the Shift or Ctrl keys while clicking the mouse can make multiple selections Right click the mouse and a menu will appear Select Add Selected To Device to add the file to the Connected Device window ready for download to the DA3 Innovative Technology Ltd Validator Programming System VPS Version 1 0 7 ITL VPS Hardware Detected Serial Number 1010 Free space 3 19 M bytes Firmware Version VPS 1001000000000 Export Setup File Import Setup File Loaded Datasets country teens ruse betes B nvr B e B we M wv B evn B sveo 904 SISUNITED KI 5 10 20 124 GBPO2 J ISUNITED Kl 1 5 10 20 1 5 10 20 GBPO3 ISUNITED KI 5 10 20 124 GBPOB 906 SISUNITED KI 5 10 20 510 20 GBPOS 903 SESUNITED Kl 1 5 10 20 1 5 10 20 GBP14 901 B 510 20 510 20 GBP21 ZISUNITED Kl 5 10 20 124 GBPOS SISUNITED KI 5 10 12 GBP27 EISUNITED KI 5 10 20 5 10 20 GBP28 Binary SSP Parallel Pulse ccTalk SSP Parallel Pulse MDB SSP Parallel Pulse Simple serial 2 SSP Parallel Pulse Simple serial SSP Parallel Pulse Update Device Summary Infomation Connected Device Dataset Library Firmware Library Memory Card VPS Utiites On the Connected Device screen files not yet downloaded to the DA3 will be listed in grey At this point yo
12. in the DA3 memory will be overwritten Note that new memory cards may need formatting see chapter 6 7 for more details e Press the MODE SELECT button until the COPY A DA3 LED is illuminated e Press the RUN button the RUN button will change colour from pulsing green to solid blue and the MODE SELECT button light will switch off e Press the RUN button again within 3 seconds to confirm Ifthe RUN button is not pressed a second time within 3 seconds the colour of the button will revert to green and the MODE SELECT button will re light blue If there is no memory card in slot A or the memory card is blank the centre RUN button will pulse red and the blue COPY A DA3 LED will flash a code as described in Appendix 1 e The Mode Indicator LED s will rotate in an anti clockwise direction while the entire contents of the memory card in slot A are be copied to the internal memory of the DA3 All files stored in the DA3 memory will be overwritten e When the copy is complete the centre RUN button will pulse green 7 8 COPY DA3 TOA This function copies the contents of the internal memory of the DA3 to the memory card in slot A All files stored on the memory card will be overwritten Note that new memory cards may need formatting see chapter 6 7 for more details e Press the MODE SELECT button until the COPY DA3 A LED is illuminated e Press the RUN button the RUN button will change colour from pulsing green to solid blue and
13. ll not be changed e Overwrite the stored software within a validator with pre selected tagged files using the BNV Override Download Function For example a validator programmed for UK notes with the Binary interface can be re programmed for Euro with the ccTalk interface e Test the functionality of the validator away from the host machine There are also two memory card slots to enable simple reprogramming of the DA3 away from a PC The memory cards used must be an Atmel Dataflash card part number ATA45DCBOOSD ITL Part Number 1C237 Data Connection LED RUN Button Mode Indicator LEDs Mode Select Figure 1 The DA3 Copyright Innovative Technology GA339 4 DAS User Manual NOTE To install the software you will need administrator rights to your PC Insert the Support CD into your computers CD Drive The menu should appear automatically To paion Fe aide ciei iaa Topaia ip p Aet oa r eirg i E Ll beise a ci Ree Duae CP Te AS T ar reial Fa nimi or Pa king deere LIS SLLLLLLDATI TCI Lick erat iz raria roce Copyright Innovative Technology Double click Install VPS Software from the menu The Welcome to the VPS Setup Wizard will start Click Next The Select Installation Folder screen will be displayed Select the path where you wish to install the software C NProgram FilesNVPS is the default path Click Next A Confirm Installation screen will be di
14. ory card in slot A or B or the memory card in slot A is blank the centre RUN button will pulse red and the blue COPY A gt B LED will flash a code as described in Appendix 1 e The Mode Indicator LED s will rotate in an anti clockwise direction while the entire contents of the memory card in slot A are copied to the memory card in slot B All files stored on the memory card in slot B will be overwritten e When the copy is complete the centre RUN button will pulse green Copyright Innovative Technology P GA339 4 DAS User Manual APPENDIX 1 ERROR CODES The table below shows an explanation of the error codes displayed on the Mode Indicator LED s if the centre RUN button changes colour to red The flash code is shown by a long flash then a number of short flashes The number of short flashes indicates the cause of failure Number of flashes Cause of failure EE SEEN No validator connection found No valid download files found Download fai 8 Memory card fai APPENDIX 2 SUPPORTED NOTE VALIDATORS The DAS will operate with the following ITL products NV7 programmed firmware 1 09 or later October 2003 NV8 programmed firmware 1 09 or later October 2003 NV9 NV10 BV20 BV50 BV100 Copyright Innovative Technology GA339 4 DA3 User Manual REVISION HISTORY INNOVATIVE TECHNOLGY LTD TITLE DA3 USER MANUAL Drawing No GA339 RJS 04 01 2007 Format MS WORD 2000 Release Date Modified By 04 0
15. ovative Technology P GA339 4 DA3 User Manual 6 2 ADDING FIRMWARE FILES TO THE FIRMWARE LIBRARY Select the Firmware Library tab The screen will show all the firmware files that are currently stored in the library on your PC Click the Import button and locate the files you wish to add the firmware files will be added to the library when you click the Open button Innovative Technology Ltd Validator Programming System VPS Version 1 0 Import Interface Available interfaces Bo Bowe Boss oes vt B sve Binary SSP Parallel Pulse ecTalk SSP Parallel Pulse MDB SSP Parallel Pulse Simple serial 2 SSP Parallel Pulse Simple serial SSP Parallel Pulse Connected Device Dataset Library Ju Memory Card VPS Utites The screen lists the firmware interfaces that are stored in your library with the interfaces that are available by setting the validator switches The version of the stored firmware file is listed under the relevant product heading If the firmware for any product is not present then the version number will not be listed under the product heading To remove a file from the firmware library select the interface to be removed and right click the mouse Select Removed Selected Firmware from the menu to remove the firmware interface for all validator models Alternatively select Remove For Validator and then the validator Model to remove the file for individual validators Copyri
16. parate 12V 1500mA DC power supply or from the host machine The functions described in this chapter will not be available if the DA3 is powered only by the USB cable Host Machine Power Connection Validator Connection 7 2 BNV MATCH DOWNLOAD This mode will update the connected BNV with the latest version of dataset and firmware currently programmed into the BNV All custom settings pulses special interface etc will remain the same Tagging files has no effect when the DA3 is used in this mode For this function to operate the versions of firmware and dataset stored within the DA3 memory must be later than that stored within the connected validator e Set the BNV to SSP mode as described in the BNV product manual Depending on the BNV model this will be either by setting the dipswitches as shown on the product label or by pressing a download reset button e Connect the BNV to the DA3 as described in chapter 7 1 and apply power either from the host machine or from a separate 12V power supply e Press the Mode Select button repeatedly until the blue BNV MATCH DOWNLOAD LED is illuminated The RUN button will pulse green to indicate that this function is available e Press the Centre RUN button e The centre RUN button will change colour to pulsing blue and the Mode Indicator LEDs will rotate back and forth as communication is established and the current BNV settings are determined The DATA CONNECTION LED with flicker as data is tran
17. sferred to and from the DAS If there are no matching firmware or dataset files stored on the DA3 the centre RUN button will change colour to pulsing red and the blue BNV MATCH DOWNLOAD LED will flash a code as described in Appendix 1 e If all the files are available on the DA3 the Mode Indicator LED s will rotate in an anti clockwise direction while the firmware is updated e Once the firmware update is complete the Mode Indicator LED s will rotate in a clockwise direction as the dataset is updated e When the firmware and dataset are successfully updated the centre RUN button will change to a pulsing green light and the BNV will reset e If necessary reset the BNV dipswitches to their original positions before re connecting the BNV to the host machine Copyright Innovative Technology GA339 4 DA3 User Manual 7 3 BNV OVERRIDE DOWNLOAD This mode will overwrite the BNV with pre selected Tagged firmware and dataset files For this function to operate the DA3 must have dataset and firmware files tagged for the attached BNV model See Chapter 6 4 for details on tagging files e Set the BNV to SSP mode as described in the BNV product manual Depending on the BNV model this will be either by setting the dipswitches as shown on the product label or by pressing a download reset button e Connect the BNV to the DA3 as described in chapter 7 1 and apply power either from the host machine or from a separate 12V power supply
18. splayed Click Next When the installation is complete you will see this screen Click Close GA339 4 DA3 User Manual 5 CONNECTING THE DAS TO A PC Connection NOTE To install the drivers for the DA3 you will need administrator rights to your PC Connect the DA3 to your PC via the supplied USB cable There is no need for a separate power supply when programming the DA3 from your computer When the DA3 is only connected through the USB the functions described in Chapter 7 are not available Copyright Innovative Technology GA339 4 DA3 User Manual Welcome e te Found New The Windows Found New Hardware Wizard m s will be displayed wD Select No not this time Click Next The wizard will then ask how you want to proceed Select Install from a list or specific location Advanced Click Next The Search and installation options screen will be displayed Select Include this le it tr in eer ih eh ea location in the search Click browse and asian 000 locate the driver files The driver files are A naa a E stored within the installation directory of eal la the VPS software which is C Program files VPS ITL VPS USB Driver by default Click Next Pete chee per mbh od adele mdan Hardware Inalbation Tha borane pena and inibaling for thas handeank ITL EV Sera hai not pasa ed window Logo teating bo weno iz compatiblitg with wind MP T
19. the MODE SELECT button light will switch off e Press the RUN button again within 3 seconds to confirm f the RUN button is not pressed a second time within 3 seconds the colour of the button will revert to green and the MODE SELECT button will re light blue If there is no memory card in slot A the centre RUN button will pulse red and the blue DA3 A LED will flash a code as described in Appendix 1 e The Mode Indicator LED s will rotate in an anti clockwise direction while the entire contents of the DA3 are copied to the memory card in slot A All files stored on the memory card will be overwritten e When the copy is complete the centre RUN button will pulse green Copyright Innovative Technology GA339 4 DA3 User Manual 7 9 COPY A TO B This function copies the contents of the memory card in slot A to the memory card in slot B All files stored on the memory card in slot B will be overwritten Note that new memory cards may need formatting see chapter 6 7 for more details e Press the MODE SELECT button until the COPY A B LED is illuminated e Press the RUN button the RUN button will change colour from pulsing green to solid blue and the MODE SELECT button light will switch off e Press the RUN button again within 3 seconds to confirm f the RUN button is not pressed a second time within 3 seconds the colour of the button will revert to green and the MODE SELECT button will re light blue If there is no mem
20. u can select which files to tag to be used for the BNV Override Download function see Chapter 6 4 Click on the Update Device button to save the listed files to the DA3 memory To remove a file from the DA3 select the files to be removed and right click the mouse Select Removed Selected from the menu to remove the files for all validator models or select Remove For Validator and then the validator model to remove the file for individual validators Click on the Update Device button to update the DA3 memory and remove the files Copyright Innovative Technology GA339 4 DA3 User Manual 6 4 TAGGING FILES FOR OVERRIDE In the Connected Device window click the revision code under the relevant product heading to tag the required dataset Each product can have a different dataset tagged For example NV7 could be tagged as UK whereas NV8 could be Euro The tagged datasets will be highlighted as red text The same procedure should then be used for tagging the firmware interfaces for each product See Chapter 7 3 for details on the BNV Override Download function Innovative Technology Ltd Validator Programming System VPS Version 1 0 7 ITL VPS Hardware Detected Serial Number 1010 Free space 3 19 M bytes Firmware Version VPS 1001000000000 Export Setup File Import Setup File Loaded Datasets Cay Deromat Puse oana v we B wo M wvo vn ov v 904 SHEUNITED KI 5 1020 124 GBPO2 ZFS UNITED
21. urrently stored in the library on your PC Click the Import button and locate the files you wish to add the datasets will be added to the library when you click the Open button Innovative Technology Ltd Validator Programming System VPS Version 1 0 5 10 20 50 510 20 50 EUR33 5 10 20 50 510 20 50 EURO2 906 10 20 50 100 5 10 205 EUROS 906 510 20 510 20 EUR10 905 0 0 5 0 0 10 2 0 0 1 0 0 EURIS 901 10 20 50 10 1 2 410 EUR4S 904 540 20 124 GBPO2 904 1 5 10 20 1510 20 GBPO3 540 20 124 GBPO6 306 540 20 5 10 20 GBPO9 903 1 5 10 20 151020 GBP14 901 SEUNITED KIN 5 10 20 510 20 GBP21 EI UNITED KIN 5 10 20 5 10 20 GBPO2 SEUNITED KIN 5 10 20 124 GBPO9 SEUNITED KIN 5 10 12 GBP27 EE 540420 5 10 20 GBP28 540 20 510 20 GBP29 LM ic The screen lists the currencies that are stored in your library with the note denominations number of pulses and the dataset code The revision code of the dataset is listed under the relevant product heading If the dataset for any product is not present then the version number will not be listed under the product heading To remove a file from the dataset library select the dataset to be removed and right click the mouse Select Removed Selected Datasets from the menu to remove the dataset for all validator models Alternatively select Remove For Validator and then the validator model to remove the file for individual validators Copyright Inn

Download Pdf Manuals

image

Related Search

Related Contents

Cypress Perform CY62147EV30 User's Manual  de Gebrauchsanleitung fr Mode d`emploi it Istruzioni  Hama 00115555 game console accessory  PCG-R600HFK - Sony Europe  Mode d`emploi  Thesis - Técnico Lisboa  DS 5000 Series User Guide  AirPort MD8 Luftkeimsammelgerät  取扱説明書 - i kitchen  JEM AF-1 DMX FAN – Operating Instructions  