Home

Pressure relieving mattress

image

Contents

1. For a quick check adjust the pressure to Firm Incomplete inflation 2 Check to see if the inflation tubes connected to the pump are twisted or disconnected Low pressure or any leakage occurring Always keep the tubes straight Change the tubes if there is any leakage 7 Disposal of the product The product can not be disposed of with household waste but must be brought to the local recycling centre Follow the national requirement to dispose the pump It should be delivered to the deposit station for re use or recycling 8 Guarantee terms Mobilex A S offers guarantee by errors in production It is 2 years of warranty for pumps production defects amp 1 year of warranty for mattress pads production defects The guarantee is not valid by not intended use of the product Parts subject to normal wear are not covered by the guarantee unless wear is caused by a manufacturing fault In the event of damage please notify your dealer The guarantee does not cover transport cost The guarantee does not cover injury or other damages eventually related to a malfunction of this product Rev 10 13 Page 6 of 7 UM 270011 GB Mobilex A S laf e Se ae 4 Mobilex www mobilex dk 9 Declaration of Conformity CE The company Mobilex A S Gr nlandsvej 5 8660 Skanderborg Denmark declares that the product Anti decubitus Mattress amp Pump Set Pump type OLA Q1 O2 amp Mattress type 250E Item 270011 is designed in accordanc
2. lt 4 il aw DK 8660 Skanderborg 4O DI cx www mobilex dk Bubble Pad e Any obvious blood spots should be wet thoroughly with 1 9 Hypochiorite solution e 1 part bleach to 9 parts water and allow drying for at least 10 minutes Then blot with a clean damp cloth e Brush or wipe down all surfaces with soap and water before applying any liquid e Allow it to thoroughly air dry Once the inside is dry turn it back wipe down the outside of the bag with disinfectant e Dry the bubble pad on a SUNLESS area after cleaning Maintanance e Check the power cord and plug to see if there are abrasions or excessive wear e Plug in the pump and check the airflow from the hose connection port The airflow should alternate between ports every half cycle time e For storage lay the bubble pad flatly Fold or roll it carefully Unplug the pump and store with proper identification tag Store device in dry places with non freezing temperatures 6 Most common problems and solutions Problems Solutions 1 Check if the plug is inserted firmly into the outlet 2 Turn on the power switch again The pump doesn t 1 If the power indicator is ON and the pump still doesn t work contact your local dealer work immediately 2 If the power indicator is OFF there may be a faulty outlet Try to connect the power cord to another outlet If the power indicator is still OFF contact a qualified electrician for main power check 1
3. is turned on Transport recommendations The device was not designed for frequent transportation If it is necessary to transport it we recommend to disassemble it in the way opposite to the assembly description from above Device should packed in the way that it is stable and there is no risk of sudden and dangerous movements of the transported device Accessories There are no accessories provided for this device 4 Technical data Pump Specification Dimensions 23x11x8 1 cm 9 1x4 3x3 2 in Weight 1 1 kg 2 4 Ibs Pressure Range 50 95 mmHg Cycle Time 6 min 50Hz 5 min 60Hz Rev 10 13 Page 4 of 7 UM 270011 GB Mobilex A S Grenlandsvej 5 f lt 4 il aw DK 8660 Skanderborg YC N Dl cx www mobilex dk Mattress Pad Description Dimensions Material Max Load 250E Bubble pad 198x89x6 3 cm PVC 100 kg w positioning extension System Specification Li Classification t Class AP APG NO Type BF Applied Part Mattress Pad Input Rating AC 120V 60Hz or 100V 50 60Hz or 230V 50Hz 12W 1A Fuse Rating 250V T1A Air Output 4 Liter min Environment Requirements e Temperature Operation 50 F 95 F 10 35 C Storage 5 F 122 F 15 50 C Shipping 5 F 158 F 15 70 C e Humidity Operation 20 80 non condensing Storage 10 90 non condensing Safety Standards UL c UL CE Product label The product label is located in the bottom
4. of the frame CE A Mobiles 7 ump for MOBILEX A S anti decubitus N rskovvej 1 mattresses DK 8660 Skanderborg Tel 45 87 93 22 20 www mobilex care com Produced S os Serial no e Sample of the product label only not original 5 Cleaning amp Maintenance Cleaning In this section we describe the procedures to clean and decontaminate the pump and bubble pad It is important to follow these procedures before using the system on patients The cleaning task is required at least once a week to maintain personal hygiene Pump DO NOT immerse or soak the pump Check for external damage and move the pump to a cleaning area Place the pump on a work surface and spray or wipe the outside of the case with quaternary ammonium solution DO NOT spray any cleaning solution directly on the surface of the pump DO NOT use a Hypocarbonate or Phenolic based cleaning solution as this may cause damage to the case Allow the solution to incubate for 10 minutes or accordingly as stated by the cleaning product used Spray cloth with cleaning solution and clean faceplate DO NOT allow excess cleaning solution on faceplate or control panel If solution gets inside damage will occur Allow surface to thoroughly dry after cleaning After the pump is thoroughly cleaned and dried proceed to plug in the pump and test to see if it runs normally Rev 10 13 Page 5 of 7 UM 270011 GB Mobilex A S Grenlandsvej 5 f
5. Mobilex A S _ mq Se 4 Mobilex www mobilex dk Anti decubitus Mattress 250E Users manual Manufacturer MOBILEX A S Gr nlandsvej 5 DK 8660 Skanderborg Denmark www mobilex dk Rev 10 13 Page 1 of 7 UM 270011 GB Mobilex A S Grenlandsvej 5 f lt 4 il aw DK 8660 Skanderborg YC N DI cx www mobilex dk 1 General information Dear customer This user manual contains a description of the medical device and important guidances to ensure a correct and safe usage of the product It is important prior to use to read this manual carefully It is especially important to read the safety requirements and follow these We continuously develop our products and we reserve the right without further notice to change the specifications and functions of products Intended use of the device The Mobilex Product is medical device which is intended to be used only as an air support surface system for human body It is suitable for pressure ulcer prevention and treatment It has been specifically designed for prevention of bedsores and offers an affordable solution to 24 hour pressure area care It can maximally be loaded with 100 kg Any other use is prohibited Contraindications Patient conditions for which the application of pressure relieving therapy on an alternation system is contraindicated are as follows cervical or skeletal traction unstable spinal cord injuries By questions please take contact to your dea
6. cted to the inflation nozzles on the pump e Cover it with a cotton sheet to avoid direct skin contact and reduce friction e Hang the pump over the frame or board at the foot end of the bed using the foldable hook hangers Make sure the pump is secured e Connect the inflation tubes ends to the mattress pad nozzles and to the pump s inflating Rev 10 13 Page 3 of 7 UM 270011 GB Mobilex A S Grenlandsvej 5 f lt 4 il aw DK 8660 Skanderborg YC N DI cx www mobilex dk nozzles Make sure the tubes are properly attached and that they sit tight on the nozzles e Make sure the inflation tubes are not kinked or tucked under the pad Before inserting the plug into the outlet make sure the voltage is compatible e Plug the power cord into an electrical outlet with grounded AC power If the power cord has a grounding wire with a grounding pin then this three wire plug must be plugged properly into an outlet and grounded as shown in the figure in the Grounding description section e Make sure this product is well grounded e Make sure to disconnect the pump by unplugging the power cord when it is not in use Grounding description This product should be grounded when it is equipped with a cord that contains a grounding wire with a grounding plug In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current Improper use of the ground
7. ctor via the three wire power cord the three blade plug shall be inserted only into a socket outlet that provides a protective earth contact 3 Description Product description The device comes with all the necesary features for efficient decubitus prevention It consists of fewseparate elements No tools are required for assembly Devices are supplied in carton boxes detached in to few elements for easier transportation The contents are e 1 Pump 1 Mattress Pad 1 Set of Inflation Tubes 1 User manual Foldable Hook Hangers in the top back side of the pump Power Switch on right side of the pump Pressure adjust Knob Inflation Nozzles here connect Inflation Tubes Power Cord Q1 O2 OLA compressor Assembly description With looking on the picture above the device should be assembled in quite instinctive way We recommend you to follow below steps e Inthe first place take all elements out of the box and check with the list from above if nothing is missing If you d discover at that stage that some part is missing or damaged do not continue assembly process Contact your supplier of the product right away e Lay the mattress pad on a foam base or other regular bed mattress Do not put it directly on the bed frame Please refer to the Specifications section for details e The inflation tubes should be towards the foot end so that they can be conne
8. e with the technical documentation and made of which conforms to the following basic requirements e EU Council Directive 93 42 EEC for medical equipment Annex I of the June 14 1993 Lars Nygaard Managing Director abs f Mobilex A S EIE owd Skanderborg the 2010 04 29 OOOOAANAAAAENAEEERAEEEESNEEENEREEEEESREEEEE EEEE signature Rev 10 13 Page 7 of 7 UM 270011 GB
9. ing plug can result in a risk of electric shock Check with a qualified electrician or serviceman if the grounding instructions are not completely understood or if in doubt as to whether the product is properly grounded If it is necessary to use an extension cord use only a 3 wire extension cord that has a three blade grounding plug and a 3 slot receptacle that will accept the plug on the product Replace or repair if damaged Function description e Turn on the power by pressing the power switch at the right side of the pump The indicator of the power switch will come on The pump starts to pump air into the mattress pad e For time saving in the first inflation turn the pressure knob to the full Firm Hard position It requires approximately 10 minutes for a bubble pad to be fully inflated e When mattress pad is fully inflated turn the pressure adjust knob to set a comfortable pressure level from soft to firm according to patient s weight and comfort e It is recommended that the pressure adjust knob being turned to Firm when the bubble pad is firstly inflated Users can then easily adjust the pressure level of the bubble pad to a desired firmness by themselves or according to the suggestion from a health care professional e lf the pressure is consistently low check for any leakage occurring in inflation tubes Contact your local dealer for replacement of any damaged tubes e The deflating inflating cycle runs automatically when pump
10. ler or directly to Mobilex A S Mobilex A S Gr nlandsvej 5 Phone 45 87 93 22 20 DK 8660 Skanderborg Telefax 45 87931777 Denmark E Mail info mobilex dk 2 Safety requirements General e Make sure that this user manual is read by all persons using the device Manufacturer doesn t take any responsibility for damages and or injuries caused by the fact that the user manual has not been followed Only use the product in flawless condition If defects or errors are detected you must immediately contact the dealer Follow the information on the product label Only use the product for the described purpose Avoid making constructive changes on the device unless you have the manufacturer s written acceptance for such modifications The device must only be used on beds equipped with regular mattresses It is forbidden to put the antidecubitus mattress directly on bed s frame e The device must not be loaded with more than 100 kg The device is dedicated to be used indoors only e A physical occupational therapist should assist in first adjustment of the device for optimum support and correct functionality Electrical To avoid incidents and to reduce the risk of burns electrocution fire or injury to persons while using electrical products especially when children are present basic safety precautions should always be followed including the following e Always unplug this product immediately after use e Do not use while bathing e Do n
11. ot place or store product where it can fall or be pulled into a tub or sink e Do not place in or drop into water or other liquids e Do not reach for a product that has fallen into water Unplug immediately The device is not intended to be self propelled while seated e Close supervision is necessary when this product is used by on or near children or invalids e Use this product only for its intended use as described in this manual e Do not use attachments not recommended by the manufacturer e Never operate this product if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return the product to a service center Rev 10 13 Page 2 of 7 UM 270011 GB Mobilex A S Grenlandsvej 5 f lt 4 il aw DK 8660 Skanderborg YC N dil cx www mobilex dk for examination and repair e Keep the cord away from heated surfaces e Never block the air openings of the product or place it on a soft surface such as a bed or couch where the air openings may be blocked Keep the air openings free of lint hair and the like e Never drop or insert any object into any opening or hose e Do not use outdoors or operate where aerosol Spray products are being used e Connect this product to a properly grounded outlet only See Grounding Instructions Grounding Before any connection is made make certain that this product shall be connected to a protective earth condu

Download Pdf Manuals