1. 3 3 The PABC GUI User menus and their actions The PABC user panel has a number of different buttons to manipulate the APD config uration and apply it to the FEECs In addition it is possible to reset the RCU and to configure which crystals to read out during data taking 18 The user actions are separated into several Menu groups Different menu groups have different domains of actions The available menu groups and their domain of actions is explained below A detailed description is given in the following sub chapters e Menu This is the main menu that deals with the interaction with the database It loads configurations from the database into the local working directory and saves configuration from the local directory to the database e Sandbox The word sandbox refers to your local playground Actions in this menu group only applies to files in the local working directory home phos data A PD_settings e Electronics Configuration This the menu that interacts directly with the elec tronics It has several sub menus Apply APD settings Applies the settings in the local working directory to the electronics Please note that applying the settings to the electronics does not store the data in the database If you want to save the settings that was applied use the save configuration button in the Main menu RCU Menu to reset RCUs and to configure trigger settings Readout Configuration Menu to select readout region 3 3 1 Me
2. usr local sbin boa usr sbin crond 1 9 c etc crontab usr local sbin writer sh usr local sbin sshd root pts 0 sh bin sh home phos feeserver_start sh bin feeserver bin feeserver bin feeserver usr local sbin sshd root pts 1 sh ps In this case the feeserver is running with Process Ids PID 972 973 974 while the script that started the feeserver has PID 971 Please note that the PIDs will vary 28 4 9 Start a feeserver on the DCS card To start the DIM servers first log into the card where you want to start the feeserver Section 4 7 To start the feeserver do the following any machine gt ssh root alphsdcsXXXX ssh root alphsdcsXXXX s password dcs alphsdcsXXXX home phos feeserver_start sh Here XX XX represents the serial number of the DCS card If for instance you are logged in to alphsdcs0279 and wants to start a feeserver there then do the following any machine gt ssh root alphsdcs0279 ssh root alphsdcs0279 s password dcs alphsdcs0279 home phos feeserver_start sh When the feeserver is started it will issue several lines relevant and irrelevant information on the command line If the feeserver was started up successfully the las few lines of information should look exactly like this init services for configuration PHOS done Init OK DIM Server successfully started ready to accept commands Anything else means that there i some kind of problem To solve
3. 1 1 6 The Control Engine CE The control engine CE runs on the DCS cards an is a part of the feeserver software The CE interprets the content of data sent via DIM and also provides service data to the feeclient for instance temperatures of the electronics In addition the CE takes care of the communication between the RCU and the front end electronics 1 1 7 The Feeclient The feeclient is a DIM client with some additional functionality There is also a PHOS version of this client In the DCS software this client is called the PhosFeeClient From now on we will refer to this client as the feeclient 1 2 The PHOS DCS infrastructure Figure 1 2 shows schematically the communication infrastructure for a single PHOS mod ule When the feeserver on one of the four DCS cards starts it automatically register itself and its services on the DIM DNS server When the PABC GUI starts up it automatically starts a feeclient that communicates with theese feeservers There is only one such client in the system The client requests services from the feeservers running on the DCS cards by contacting the DIM DNS node The DIM DNS node replies by giving the service information to the client Thereafter the client and the servers communicates directly independently of the DIM DNS node There is four readout partitions on a single module Correspondingly it is indicated a one to four relationship between the feeclient and the feeserver The Figure would have
4. 5 3 2 Messages when Arming trigger ooo a 20004 36 5 4 Error whe mstarting a feeserver DIM server aoa a a 36 5 5 Error when Niarting DIM INS server oaoa 36 5 6 Error message when starting DID aoaaa aaa at 5 7 Error when startingtthePABC GUI 04 37 5 8 Error when applyinB gD settings 000 eee eee 38 5 8 1 ERROR 1 No response from FEE 38 58 2 ERROR 3 DCS is not master c o ce ee ES 39 5 8 3 ERROR 3 Readback values are crazy aoaaa aaa 39 Bibliography 40 A Conversion between DAC and High Voltage 41 B Software Document 43 List of Figures LA 1 2 21 3 1 Communication via DIM dI 9 The PHOS DCS Communication infrastructure via DIM for a single PHOS module 2 ee Gh 11 The DIM Information Display DID 16 The PABC Graphical User Interface GUI NR ee 18 List of Tables A 1 Correspondence between DAC values and High Voltage Abbrevations APD CSP DCS DCS card DID DIM DIM_DNS FEE FEEC GUI HV LV PABC PC PHOS RCU Avalanche Photo Diode Charge Sensitive Pre amplifier Detector Control System Detector Control System card DIM Information Display Distributed Information Managment DIM Dynamic Name Server Front End Electronics Front End Electronics Card Graphical User Interface High Voltage Low Voltage Phos APD Bias Control Personal Computer Photon Spectrometer Readou
5. alphsdcsXXX kill 9 XXX Where XXX represents the PID of the process For the example given in Section 4 8 XXX 972 an you would kill it with the command alphsdcsxXxX kill 9 972 In addition There is currently two more ways to kill the feeservers One is to turn on and off the power of the DCS RCU card The other one is to reboot the DCS card Please not that in the near future the feeserver will start up automatically on reboot or power up an it will not be possible to kill the feeserver by turning on off power or by rebooting If you want to kill the feeserver by rebooting do the following 30 alphsdcsXXXX reboot After this command you will loose contact with the DCS card The DCS card will use 1 min to reboot Shortly after the reboot command the command prompt should look like this alphsdcsXXXX Connection to alphsdcsXXXX closed by remote host Connection to alphsdcsXXXX closed any PC gt 4 11 Log in to the PC where the PABC and the DIM DNS server is running The PABC GUI the DIM DNS server and DID will all run on the PC alphspcdcs01 cern ch This PC is currently situated in the corner behind the PHOS module in 167 R 006 You can either log in directly to this PC with user name phos and password phosbeamtest or remotely from another machine To log in remotely via the network do the following any PC gt ssh phos alphspcdcs01 Scientific Linux CERN Release 3 0 6 SL phos alphspcdcs01 s pass
6. 25 applying APD values for cardX at branchY SUCCESS If you get any other message go to Chapter 5 8 4 3 Apply APD settings to all cards on readout par tition The readout partition RCU you want to aplly the APD bias settings too must be selected An readout partition is selceted if it has the color blue To apply the current APD configuration click the button Apply to RCU button 4 4 Apply APD settings to all cards of the Module Click the Apply to Module button in PABC GUI 4 5 Take data Before attempting to take any data please make sure that ALL FEECs of all four readout partition is ON even if you are only taking data from a part of the PHOS module There is several issues conflicts between DAQ and DCS The problem is that DAQ occasional leaves the RCU in a state of error when it is impossible to access it from DCS or to take any data There is however a recipe to follow that will keep the system working both for DCS and DAQ DATE The recipe is given below Recipe for taking data 1 PABC click the Disarm Trigger button if it was not already done after previous run If you are not sure if you clicked the button just click it in any case 2 PABC optional apply new APD bias settings PABC click the Arm Trigger button DATE click Start Process and the Start PABC click the Enable Trigger button Wait until you have enough events from DATE PABC click the Disarm Trigger button Go PE Oe Oe Re DATE click Stop
7. 26 4 6 Initialize the RCU s WARNING before clicking the initialize RCU button please make sure that the LV voltage for the FEE and CSPs and the HV is OFF The RCU is initialized evry time the DCS cards is rebooted or the power for the RCU is switched on It should therefor normally not be necessary manually to intialize the RCU Howevere it might be that for various reasons the RCU must be re initialized To initialize an RCU first click on the readout partition corresponding to the RCU that you want to initialize After selecting the RCU wait a few seconds to let the DCS card probe the electronics Then click the Initialize RCU button in the RCU menu group in the PABC GUL This will intialize the currently selected RCU the one marked with blue If no RCU is selected you will get an error message from the Logviewer If you want to initialize all four RCUs you will have to select them one by one and repeat the procedure 4 7 Log in to a DCS card To log in to a DCS card do the following any PC ssh root alphsdcsXXXX root alphsdcsxXXxXX s password dcs Here XXXX represents the serial number of the DCS card For the moment the available DCS cards is alphsdcs0060 0279 0280 0281 0282 For instance if you want to log in to the DCS card with serial number 0279 replace XX XX with 0279 and do the following any machine gt ssh root alphsdcs0279 ssh root alphsdcs0279 s password dcs alphsdcs0279 home phos feeser
8. gt o cancan ea dee ee AES 3 3 6 Menu Electronics Configuration 2 22 oot The LogViewet iw eb ee Pe eee eek ee ee Bee eS 24 4 PABC How To 25 di Ture ONVOPF a FEEC eo es ee be ee eee He EEG ee Res 25 4 2 Apply APD settings to a single FEEC 20 4 25 4 3 Apply APD settings to all cards on readout partition 26 4 4 Apply APD settings to all cards of the Module 6 26 AS Take data oe be ee OOK EERE DEES ES BI eG ad 26 4 6 Initialize the RCU s lt 7 Sm 27 Ay oe im toe DCS tat gb ce hee we we a O Me ces 27 4 8 Check if the feeserver is running 4e m 27 4 9 Start a feeserver on the DCS card 49 4 29 4 10 Kill a feeserver running on the DCS card 4 4 7 29 4 11 Log in to the PC where the PABC and the DIM DNS server is running 31 4 12 Check if the DIM DNS server is running Ia 31 4 13 Start the DIM DNS server ea Ny 32 4 14 Kill the DIM DNS server Ta 32 4 15 Kill the PABC GUI A v 33 4 16 Killa process i general 9M JS Sy 33 5 Troubleshooting 34 5 1 I cannot take any datak MM MR 2 22 ee ee eee 34 5 2 I cannot turn on the froNfend agridem ee 35 5 3 Interpretation of messages from the LogViewer 35 5 3 1 Messages when applying APD bias settings o oo aaa 35
9. Save Configuration button 3 3 6 Menu Electronics Configuration This menu groups contains several sub menus Actions in this menu group is applied to the electronics Warning Make sure that High Voltage is turned off before making any changes to the APD DAC values The High Voltage must be ramped up after the APD settings is applied Apply APD settings e Apply to FEE Applies the setting shown in the 2x16 matrix of crystals APDs that is currently selected The currently selected FEEC is marked with blue by click from the user If no card is selected an error is issued on the command line Please note that clicking this button only attempts to apply the settings for the selected FEEC as it is given in the folder home phos APD settings it does not store any data in the configuration database e Apply to RCU By clicking this button all the APD settings for the currently se lected RCU in the sandbox directory home phos data APD_settings is applied to the FEE The settings is applied one by one on FEEC basis e Apply to module Disabled for the moment RCU All buttons in this menu group perform actions on all RCUs of the PHOS module except the Initialize RCU button that initializes only the currently selected RCU the one colored blue e Initialize RCU Performs the following actions Resets the the RCU driver Resets the DCS firmware Reloads the firmware for the currently selected RCU equivalent to the com mand Oxb
10. click the ON OFF button for the card The ON OFF button of the FEEC is the small button on top of each of the cards Clicking the ON OFF button will attempt to turn the FEEC OFF if it is already on otherwise the PABC will attempt to turn it ON If you successfully turned ON the FEEC the ON OFF button will turn green as indicated in Figure 3 1 The LogViewer will issue the message CardX at branchY was turned ON pcmversion is 0x20 If you get any other messages you can try to do it once more If you still don t get this message go to section 5 2 4 2 Apply APD settings to a single FEEC To apply APD settings to a FEEC the card must be turned on see Section 4 1 and the card you want to apply the APD settings to must be selected To select the card just click on the card The card should turn blue and the current APD settings of the card will be shown in the 2x16 matrix to the right The PABC GUI should look something like Figure 3 1 Please note that the entries in the 2x16 matrix does not necessarily reflects the APD bias settings of the actual front end card unless you apply the settings successfully to the electronics To apply the settings of the currently selected FEEC in the GUI to the electronics click the Apply to FEE button in the Apply APD settings sub menu under the Electron ics Configuration menu If the APD settings was applied correctly the LogViewer will issue the message The pem version number is subjected to changes
11. it directly on alphspcdcs01 To start DID do the following any machine gt ssh X phos alphspcdcs01 cern ch phos alphspcdcs01 s password phosbeamtest alphspcdcs01 home phos gt dcs_cern sh sets up the enviroment alphspcdcs01 home phos gt did 14 Now the DID information display will show up To view all available servers select View from the menu and then all servers It is useful to also select from the menu Com mands and then Set Debug On Currently the display will only show one server the DIM DNS name server 2 4 Starting the DIM servers on the DCS cards If the DCS cards are mounted on the dedicated private network on the PHOS DCS gateway alphspcdcs01 cern ch then the feeservers should start automatically when the DCS cards are powered on If the DCS cards are accessible on the CERN network then the feeservers must be started manually In the latter case the procedure described in this section must be repeated for the four DCS cards alphsdcs0060 0279 0281 0282 The procedure will be shown only for alphsdcs0279 cern ch The procedure is identical for alphsdcs0060 cern ch 0279 0281 0282 To start the DIM servers do the following any machine gt ssh root alphsdcs0279 cern ch root alphsdcs0279 s password dcs alphsdcs0279 home phos feeserver_start sh After all the four DIM servers are started you should see five servers in the DID informa tion display One ser
12. reasons The DIM DNS server is not running See Chapter 4 12 for how to check if the DIM DNS server is running and Chapter 4 13 for how to start it if it is not running The network cable is not connected properly Go to the PC alphspcdcs01 and check if the Ethernet cable is properly connected bot tho the PC and to the switch DIM Server successfully started ready to accept commands DIM FATAL alphsdcs0281 Some Services already known to DNS Framework tries to exit FeeServer 3 Most likely FeeServer name already exists Exit state 204 CE Info srczce rcu_service c line 104 releaseRcuAccess finished with e This message means that a feeserver with the same name as the one you try to start is already running Either you have tried to start a feeserver twice on the same DCS card or a feeserver with the same name is already running on another DCS card Se Chapter 4 8 5 5 Error when starting DIM DNS server Interpretation of error messages PID 11372 Sat May 27 18 12 09 2006 DNS pid 11372 starting up on alphspcdcs01 PID 11372 Sat May 27 18 12 09 2006 ERROR Opening server port Address already 36 This message means that the DIM DNS is already running The DIM DNS server uses port 2025 and port 5100 The DIM DNS server starts and then kill itself because it finds that these ports are already in use Measure Most likely everything is OK it is just not possible to run two DIM DNS servers on the s
13. 000 0x4 Resets the RCU firmware Gives the DCS card access to the readout bus equivalent to the command Oxe000 0x0 22 e Reset All RCUs Performs the following actions Reloads the firmware for all RCUs equivalent to the command 0xb000 0x4 Resets the RCUs Powers down all FEECs Gives the DCS card access to the readout bus equivalent to the command Oxe000 0x0 WANING all the FEECs will be turned off and any configuration such as for instance the APD settings of the cards will be lost After clicking the initialize RCU button The card will have to be turned on and the APD bias settings must be applied again e Arm Trigger performs the following actions Reads the number of samples pretrigger samples from the GUI an applies it to the electronics Calculate a suitable trigger window between L1 and L2 trigger from the number of samples and applies it to the electronics Generates the active channel lists AFL for the four readout partitions to read out based on the readout region specified by the user Distribute the AFLs to the four readout partitions RCUs and applies them to the electronics e Enable Trigger Enables triggers for all four readout regions e Disarm trigger Disables the external hardware trigger and resets the RCU Tells the RCU that it is a PHOS type RCU WARNING Clicking the Disarm Trigger button resets the RCU and all registers in the RCU including the register that specifies if the RCU is TPC t
14. D information display optional Make sure that a feeserver is running on each of the DCS cards Start a feeclient that communicates with the feeservers on the This will be the PABC GUI Ramp up LV for the front end electronics Make sure the the LV for the CSP preamplifiers are ON The reason is that the voltage for the DACs holding the APD bias settings is derived from the 13 7 Voltage for the CSPs 12 12 Apply APD configuration 13 Ramp up HV for the front end electronics If you want to apply new APD settings to the electronics it must be done before ramping up the HV for the APDs Otherwise the HV power supply can trip Steps that are governed by the PABC software will be explained below Turning on off voltages etc will not be explained There are in addition several other steps necessary to get a full communication chain working These steps are done automatically provided that you use the following PC and DCS cards e The DIM DNS node and the DID information display runs on the PC alphspedcs01 cern ch under user phos e The DIM servers runs on the DCS cards all as user root Which DCS cards to use is subjected to changes The currently mounted DCS RCUs are listed below alphsdcs0060 cern ch DIM name alphsdcs0060 alphsdcs0279 cern ch DIM name alphsdcs0279 alphsdcs0281 cern ch DIM name alphsdcs0281 alphsdcs0282 cern ch DIM name alphsdcs0282 e The PABC GUI runs on the PC alphspcdcs01 cern ch If you wan
15. Local Guide to the PHOS EMCAL APD Bias Control PABC software Version 4 Per Thomas Hille Department of Physics University of Oslo 21 September 2006 Contents List of Figures List of Tables 1 Introduction 1 1 Terms Items and definitions Qg The Readout Control Unit RGJ WBR DCS card Sm NA Distributed Information Management DIM The DIM DNS server Q J SO The Feeserver gm WA 2 2 eee The Control Engig CE WR We ee ee ee ee eee The Feeclient Me MR 2 ee ee es 1 2 The PHOS DCS infrastiiewrr SA ee LLA L12 1 1 3 1 1 4 1 1 5 1 1 6 LL 2 Setting up the APD bias control from scratch 2 1 Preparing j Start from satch Wa ee 2 2 Starting the DIM name server M 2 ee 2 3 Starting the DIM Information Display optional 2 4 Starting the DIM servers on the DCS cards 2 5 Starting the APN RUI he DIM client 4 3 Using the PABC Graphical User Interface apdgui 3 1 Starting the PABC Graphical User interface 3 2 Actions of the PABC program at startup 204 3 3 The PABC GUI User menus and their actions 3 3 1 3 3 2 3 3 3 3 3 4 3 3 9 Menu Menu Menu Menu Menu Phos Module as seen from the back 0 Front End Cards o oso cc ccoa 04 4 Sh ee Ree Re RE eG APD DAC walues
16. S DCS software is based on DIM DIM was developed at CERN for the Delphi experiment and is widely used in several other experiments at CERN DIM like most communication systems is based on the client server paradigm The basic concept in the DIM approach is the concept of service Servers provide services to clients A service is normally a set of data of any type or size and it is recognized by a name named services The name space for services is free Services are normally requested by the client only once at startup and they are subsequently automatically updated by the server either at regular time intervals or whenever the conditions change according to the type of service requested by the client The client updating mechanism can be of two types either by executing a callback routine or by updating a client buffer with the new set of data or both In fact this last type works as if the clients maintain a copy of the server s data in cache the cache coherence being assured by the server 1 1 4 The DIM DNS server In order to allow for transparency as well as to allow for easy recovery from crashes and migration of servers a name server is used Servers publish their services by registering them with the name server normally once at startup Clients subscribe to services by asking the name server which server provides the service and then contacting the server directly providing the type of service and t
17. ame PC If you really wants to make sure that everything is OK then see Chapter 4 14 and Chapter 4 13 for how to kill the server that is running and to start your own Before you kill the DIM DNS server talk to your colleagues so that you don t interfere with their work alphspcdcs01 home phos gt dns bash dns command not found Reason you have forgotten to set up the environment variable To set up the environment do alphspcdcs01 home phos gt dcs_cern sh Don t forget the dot space 5 6 Error message when starting DID alphspcdcs01 home phos gt did PID 4070 Sun May 28 13 18 51 2006 ERROR Connecting to DIM_DNS on alphspcdcsO1 cern ch Connection refused This message means that you have forgotten to start DIM DNS server See Chapter 4 13 for how to start the DIM DNS server DID crashes It can happen that DID crashes if you run it remotely due to a bug in DID You will get an error message about segmentation fault If this happen you can try to run DID directly on the PC 5 7 Error when starting the PABC GUI When starting the PABC GUI the GUI looks strange for several minutes and then it appear correctly Reason The PABC GUI is not able to contact the DIM DNS server The timeout period 37 is several minutes and in the meantime the PABC will hang Either the DIM DNS server was not started or there are some network problems If you are running the PABC GUI apdgui on the PC alphspcdcs01 cern ch th
18. atrix the blocking time should be around 200 300 us Check that you have enables the correct LDCs in DATE Make sure that only the DATE Equipments that you want data from is activated If you activate an equipment in DATE but the readout region you want does not include any readout channels from that Equipment RCU then date will still expect data from it and will wait forever for data from that equipment There are four DATE equipments per PHOS Module The DATE name of these equipments is DDL8 DDL9 DDL10 DDL11 and they corresponds to RCUO alphsdcs0060 RCU1L alphsdcs0279 RCU2 alphsdcs0281 and RCU3 alphs dcs0282 respectively To activate deactivate equipments issue the command editDb on the command line of the DAQ computer currently aldagpc019 5 2 I cannot turn on the front end cards Checklist e Make sure that the frontend card you want to turn ON is actually connected e Check if the feeserver is running 4 8 5 3 Interpretation of messages from the LogViewer 5 3 1 Messages when applying APD bias settings See Section 4 2 and 5 8 35 5 3 2 Messages when Arming trigger 5 4 Error when starting a feeserver DIM server Interpretation of error messages DIM ERROR Connecting to DIM_DNS on alphspcdcs01 cern ch Connection ref DIM Server successfully started ready to accept commands This message from the feeserver means that feeserver started correctly but did not manage to contact the DIM DNS server Possible
19. en the reason is that the DIM DNS server was not started See Chapter 4 13 for how to start the DIM DNS server ERROR could not turn on CardX at branchY Reason DCS is not master There is several possible reasons for this message e The RCU was not reseted after it was powered up measure Reset the RCUs See Chapter 4 6 for details e The feeserver is not running measure Check if the feeserver is running Chapter 4 8 If it is not running the start the feeserver Chapter 4 9 e Somebody have changed the access rights of DCS by for instance running scripts from the command line of the DCS card measure Reset the RCUs Chapter 4 6 If none of the measure does not solve the problem it might be necessary to set up the system from scratch See Chapter 2 for details 5 8 Error when applying APD settings 5 8 1 ERROR 1 No response from FEE When attempts is made to apply APD settings to the FEE the LogViewer issues the message applying APD values for cardX at branchY ERROR 1 No response from FEE This message means that the PABC is not able to establish contact with the given FEEC possible reasons e FEEC is not turned ON measure Turn ON the FEEC Section 4 1 e The FEEC has no power measure Turn on power for the FEEC e The FEEC is not present measure Connect a FEEC on the corresponding slot on the GTL backplane and turn it ON Section 4 1 38 5 8 2 ERROR 3 DCS is not master When attempts is made t
20. ent e It to establish contact with DIM DNS server and asks for the services of the feeservers running on the DCS cards it will use the DIM DNS server defined in the setup script dcs_cern sh the folder home phos e It attemts to establish contact with the feeservers 17 Vv PHOS APD bias control e Aug 01 22 58 50 2006 applying APD values for card3 at branchl SUCCESS e Aug 01 22 58 50 2006 applying APD values for card4 at branchl SUCCESS e Aug 01 22 58 51 2006 applying APD values for cardS at branchi SUCCESS e Aug 01 22 58 52 2006 applying APD values for card6 at branchi SUCCESS e applying APD values for card at branchl SUCCESS applying APD values for card8 at branchi SUCCESS applying APD values for card9 at branchi SUCCESS applying APD values for card10 at branchl SUCCESS applying APD values for cardil at branchi SUCCESS 58 applying APD values for cardl2 at branchi SUCCESS e Aug 01 22 58 57 2006 applying APD values for card13 at branchi SUCCESS e Aug 01 22 58 57 2006 applying APD values for cardl4 at branchi SUCCESS Figure 3 1 The PABC Graphical User Interface GUI e It loads the latest configuration of the APD bias settings from the folder home phos data ConfigurationFiles e It puts a copy of the latest configuration in to the folder home phos data A PD_settings e It loads the values from home phos data APD_settings into the GUI to display it to the user
21. es configuration_N 1 tat e Load Configuration Loads the configuration with the ID given by the user spec ified number to the right of the button The default value of the number entry is the configuration that was loaded at startup of the apdgui If the given con figuration does not exist an error is issued on the command line and the data in home phos data APD_settings is left untouched 3 3 5 Menu Sandbox e Set all APD for FEE to Clicking this button will set all the APD values for the currently selected FEE to the value given in the entry to the right of the button The values will be written to the sandbox home phos data APD_settings Please note that the changes will not be updated in the database unless you click the Save Configuration button e Set all APD for RCU to Clicking this button will set all the APD values for the currently selected RCU to the value given in the entry to the right of the button The values will be written to the sandbox home phos data APD_settings Please note that the changes will not be updated in the database unless you click the Save Configuration button e Set all APD for Module to Clicking this button will set all the APD values for the currently selected Module Module 2 to the value given in the entry to the right 21 of the button The values will be written to the sandbox home phos data A PD_settings Please note that the changes will not be updated in the database unless you click the
22. he type of update as parameters The name server keeps an up to date directory of all the servers and services available in the system Figure 1 1 shows how DIM components Servers Clients and the Name Server interact Whenever one of the processes a server or even the name server in the system crashes or dies all processes connected to it will be notified and will reconnect as soon as it comes back to life This feature not only allows for an easy recovery it also allows for the easy migration of a server from one machine to another by stopping it in the first machine and starting it in the second one and so for the possibility of balancing the machine load of the different workstations es a ale Request Service te a nneenes SEVICE Info Register Services Subscribe to Service PTT eee eee Ee ene Nee Sr i ain ieih LLL Tee rr aL Service Data Commands Figure 1 1 Communication via DIM 1 1 5 The Feeserver The feeserver consist of a DIM server and a software package specific to PHOS The PHOS specific software is called the Control Engine CE and contains several services specific to PHOS One such service is for instance to run scripts on the DCS card The DIM server and the CE combined is called a feeserver The feeserver runs on the DCS cards and takes commands from the feeclient the PABC GUI running on a PC and sends the results of various commands back to the PABC GUI
23. ill be created The current default value is DAC 512 for all APDs which corresponds to 300 Volt on the HV output e The color of the card will be set to blue e A 2x16 matrix of APD DAC values will be drawn in the middle of the GUI e If a card was already selected and the user selects another card then the APD settings of the previous card will be saved to the corresponding file in the folder home phos data APD_settings 20 3 3 3 Menu APD DAC values In this menu the user can change the DAC values of the individual APDs This is done either by clicking the up down arrows to the right of the number entry or by typing a number in the number entry field and pressing enter on the PC keyboard By using the up down arrows it will only be possible to set value s in the range 0 1023 If one types a number outside this range in the number entry field then if the number is higher than 1023 then it will be set to 1023 and if the number is less than zero it will be set to zero 3 3 4 Menu Menu e Exit Not yet implemented e Save Configuration Saves everything in the folder home phos data A PD_settings in a single file in the Folder home phos data ConfigurationFiles Please note that clicking this button will never overwrite any data The ID number N of the latest configuration will be read from the file home phos data ConfigurationFiles Id tat and the new configuration file will be written to the file home phos data ConfigurationFil
24. le A 1 Correspondence between DAC values and High Voltage DAC value Voltage Volt 0 210 30 215 60 221 90 226 120 232 150 237 180 243 210 249 240 254 270 260 300 265 330 271 360 276 390 282 420 288 450 293 480 299 510 304 540 310 570 315 600 321 630 327 660 332 690 338 720 343 750 349 780 304 810 360 840 366 870 371 900 377 930 382 960 388 990 393 1020 399 1023 400 42 Appendix B Software Document The the PHOS DCS software and HTML documentation is available for download at http folk uio no perthi alice doc phos_dcs tar The HTML documentation for the source code can also be viewed online at http folk uio no perthi alice doc phos_dcs htm1 43
25. looked almost the same if there were more than one lets say N PHOS modules except that there would have been a one to Nx4 relationship between the feeclient and the feeserver No matter the number of PHOS modules there will never be more than one feeclient to the feeservers Once the communication chain is established the user can send commands to the RCU and the FEE via the feeservers The feeclient can also receive service data Such service data might for instance be temperatures voltages and currents of the front end cards Unless you start the PABC GUI from more than one terminal 10 B Application software f Communication software Hardware device Figure 1 2 The PHOS DCS Communication infrastructure via DIM for a single PHOS module 11 Chapter 2 Setting up the APD bias control from scratch This chapter explains how to set up the communication chain for the PHOS APD bias control from scratch If the the communication chain already works the procedures in this chapter are not necessary To set up the communication chain requires several steps listed below The steps must be done in the given order 1 2 10 11 Ramp down HV for the front end electronics Ramp down LV for the front end electronics Turn off the voltage for the RCU DCS Turn on the voltage for the RCU DCS Reboot the PC that will run the DIM_DNS server the PABC DID Make sure that the DIM DNS node is running Start the DI
26. ng alphspcdcs01 home phos gt dces_cern sh alphspcdcs01 home phos gt dns PID 11250 Sat May 27 18 08 06 2006 DNS pid 11250 starting up on alphspcdcs0 The response from the DIM DNS server should be exactly as sown above except that the date and the PID will be different If you get any other message go to section 5 5 alphspcdcs01 see Section 4 11 4 14 Kill the DIM DNS server The only reason to kill the DNS server is for debugging purphoses when the DCS system is not working properly and you want to see the messages from the DNS server on the commandline In this case you kill it and then restart it manually from the command line There is three ways to kill the DIM DNS server Before you kill the DIM DNS server please talk to your colleagues so you don t interfere with their work 32 e To kill the DIM DNS server from the terminal window where you started the DIM DNS server type CTRL C in the terminal window where the DIM DNS server is running e If you are not in the terminal window where the DIM DNS was stared you will first have to log in to the PC running the DIM DNS server see Section 4 11 To obtain the PIDs of the processes do the following alphspcdcs01 home phos gt ps e You will get list of processes similar to that given in section 4 12 Find the PID and kill it with the command home phos gt kill 9 XXXX where XXX is the PID If for instance the PID is 3111 as in section kill it by typi
27. ng home phos gt kill 9 3111 4 15 Kill the PABC GUI If you are in the terminal window where you started the PABC GUI just press CTRL C on the PC keyboard Otherwise kill the the PABC GUI by logging in remotely from another PC to the machine that is running the PABC GUI and do the following any PC gt ps a The list of processes should look something like this any PC gt ps a PID TTY TIME CMD 25005 pts 7 00 00 01 apdgui 8456 pts 14 00 00 00 ps The executable of the PABC has the name apdgui In this examples it has the PID 25005 To kill it do the following any PC gt kill 9 25005 4 16 Kill a process i general To kill a process in general type the command ps a on the command prompt in the PC DCS card where the process you want to kill is running Look at the PID of the process you want to kill ant type on the command line any PC gt kill 9 PID 33 Chapter 5 Troubleshooting 5 1 I cannot take any data Check if triggers are arriving at the RCUs First of all check if there are triggers arriving to the RCU and also read the error register 0x7800 the trigger configuration register 0x7801 and the trigger counter register 0x78002 You can read all three register with a single command alphsdcs0279 rcu sh r 0x7800 3 0x7800 O 0x1410160 0x1780178 Repeat the procedure for the RCUs you have activated for data taking The result should look something like the one above Here there are
28. no errors 0x7800 0x0 The trigger configuration is hardware trigger and time window to L2 trigger is 0x160 clock cycles The last register says that 0x178 L1 triggers has arrived to the RCU most significant 16 bits and that 0x178 L1 triggers was accepted least significant 16 bits If you read out the trigger counter register several times and there are trigger then the counter will increase its value If triggers arrives in the RCU and you cannot take any data then the problems is somewhere else Check if the RCU is in error Read the status and error register of the RCU alphsdcs0279 xrcu sh r 0x7800 0x7800 0x80000000 The value of this register should be zero If you get anything else the RCU must be reseted This can be done by clicking the Disarm Trigger button on the PABC GUI There are several conditions that can leave the RCU in some state of error Some of the are listed below 34 e The trigger rate is to high for the RCU Measure increase the trigger blocking dead time e Date was stopped before disarming triggers Measure click the Disarm Trigger button and repeat the data taking proce dure e Triggers was enabled before DATE was started Measure click the Disarm Trigger button and repeat the data taking proce dure Please note that the trigger blocking time necessary depends on how many channels you want to read out To read out the whole module the trigger blocking time should be at least 5 ms To read out a 7x7 m
29. nu Phos Module as seen from the back The PHOS module is divided into four readout partitions The name of the partitions is identical to the DIM name of the feeserver used to communicate with that partition At the startup of the GUI the color of all the RCU partitions will be grey which means that no RCU is selected The user selects one of the RCUs by a single click with the mouse Clicking one of the RCU partition buttons of the PHOS Module will perform the following actions e The PABC will contact the feeeserver DIM server controlling that readout partition and ask for the active front end card list of selected RCU e The PABC will try to contact all the cards marked as active and if contact is established it sets the state of the corresponding FEEC to ON If contact is not established the state is set to unknown grey e The color of the selected RCU will be set to blue After all the FEECs in the active front end card list of the selected RCU is accessed the GUI will draw all the FEECs of the currently selected RCU on the bottom left of the GUI Please note that it will take several seconds for the PABC to probe all cards 19 3 3 2 Menu Front End Cards One front end card consists of two parts One small button to turn on or off the card and one long button to select the card in order to configure the APD settings The Front end card menu shows all the FEECs for the currently selected RCU The ON OFF button By clicking
30. o apply APD settings to the FEE the LogViewer issues the message applying APD values for cardX at branchY ERROR 2 DCS is not master The message means that DCS is not master of the RCU bus an is therefore not able to set the APD DAC values Reason Somebody has taken the control away from DCS by running scripts on the command line of the DCS card Measure Reset the RCU Chapter 4 6 5 8 3 ERROR 3 Readback values are crazy When attempts is made to apply APD settings to the FEE the LogViewer issues the message applying APD values for cardX at branchY ERROR 3 Readback values are crazy This means that the APD values the PABC GUI reads back from the electronics does not make sense at all Possible reasons e The feeserver is not running see Chapter 4 8 Measure Reset the RCUs see Chapter 4 6 e The RCU is in some state of fatal error because somebody ran scripts on the com mand line Measure Reset the RCUs see Chapter 4 6 In none of these measure solves the problem it might be necessary to set up the commu nication chain from scratch Chapter 2 39 Bibliography 1 http dim web cern ch dim The DIM web site 40 Appendix A Conversion between DAC and High Voltage Table A shows the correspondence between the DAC values and High Voltage Please note that these values are only rough estimates Actual HV on the APD might vary with several Volt relative to the values given in the Table 41 Tab
31. on the ON OFF button the user can turn the card ON or OFF The color of this button indicates the state of the card A click on the button will turn the card OFF if it is already ON otherwise it will be turned ON provided that the PABC is able to contact the card The meaning of the various colors of the ON OFF button is explained below e Grey The state is unknown It means that The RCU did not manage to contact the card or that the RCU has been reseted If the RCU has just been reseted from the GUI then all cards will be grey e White The card is present but power is OFF e Green The card is ON and ready to take commands from DCS e Red The card is in the state ERROR Please note that the status of the cards are only updated on selection of an RCU or when the ON OFF buttons are clicked If one has interacted with the corresponding DCS card manually by for instance running scripts on the command line of the DCS card then the state of the card might not correspond to the state shown in the PABC GUI To get the correct display of the FEE states in this case will require the PABC GUI to be closed and then started again The select FEEC button The long button below each ON OFF button is the button to select the corresponding card for APD configuration Clicking on a FEE button will perform the following actions e The current APD settings will be read from folder home phos data APD_settings If no file exists a file with default values w
32. t Control Unit Chapter 1 Introduction This is the User Manual for the PHOS APD Bias Control PABC Front End Electronics FEE configuration software The PABC GUI interacts graphically directly with the soft ware libraries that will be used for ALICE PHOS DCS in the LHC The communication with the PHOS detector is based on DIM The PHOS DCS software is separated in two parts The Configuration part and the monitoring part This manual covers the FEE configuration part The PHOS DCS FEE configuration software package consists of standalone C classes to configure the PHOS FEE and a graphical C layer to interact graphically with these classes The graphical software layer and the configuration software layer is completely separated so that the FEE configuration software can be interfaced either from the PABC GUI from PVSS from the command line or from any other program The PABC GUI is intended for commissioning and calibration of the PHOS detector For the final system the interaction with the PHOS DCS software will be via PVSS The PABC GUI however is made in ROOT The reason for the decision of making this GUI in ROOT and not in PVSS was that the requirements for commissioning and calibration is different from the requirements in the final system More specific one needs much more detailed control of the configuration during calibration and commissioning than during physics data taking 1 1 Terms Items and definitions 1 1 1 The Reado
33. t to use different DCS cards than the the ones listed above please contact the author at perthi fys uio no 2 1 Preparing to start from scratch Reboot alphspcdcs01 In order to make sure that there are no background processes that can cause trouble if you are not already logged in then log in either via the network or directly to the PC e Turn off the power for the DCS cards e Reboot alphspcdcs01 From the network 13 any machine gt ssh phos alphspcdcs01 cern ch any machine gt username phos phos alphspcdcs01 s password gt password phosbeamtest alphspcdcs01 home phos gt reboot Directly on the PC user phos username phosbeamtest alphspcdcs01 home phos gt reboot Please note that you will lose the connection to alphspedcs01 when you reboot e Reboot the DCS cards alphsdcs0060 0279 0281 0282 by turning ON the power 2 2 Starting the DIM name server The DIM DNS node should start up automatically when rebooting alphspcdcs01 cern ch If you really want to make sure that the DNS node is running go to Chapter 4 12 2 3 Starting the DIM Information Display optional The DIM Information Display DID is not mandatory but a very useful tool for debugging and monitoring of the DIM communication It can run on alphspcdcs01 or any other machine that has the necessary software and environment Note that on some occasions the DID will crash when run remotely due to a bug in DID If this happens you can run
34. them go to Chapter 5 4 4 10 Kill a feeserver running on the DCS card There is two ways to kill a feeserver running on the DCS card In the following discussion XXXX Will refer to the serial number of the DCS card Before you kill a feeserver please talk to your colleagues so you don t interfere with their work e From the terminal window where the feeserver was started press CTRL C on the PC key board No you should get back the normal command prompt an the last few line should look either like something like this 29 CE Info src_ce ce_base c line 592 program rm exited with error code 0 CE Debug issue result buffer 0x30377830 Retcode of CMND timedwait 0 Issue nRet 0 ErrorCode in Header 0 ACK alphsdcsXXXx Or something like this init services for configuration PHOS done Init OK DIM Server successfully started ready to accept commands alphsdcsXXXX e If you want to kill the feeserver from another terminal window than where the feeserver was started do the following First log in to the DCS card where the feeserver you want to kill is running see Section 4 7 To kill the feeserver process you need to know the Process Id PID See Section 4 8 for how to obtain the PID If a feeserver is running there will be three processes called bin feeserver To kill all processes associated with the feeserver it will be sufficient to kill only the first one To kill it do the following on the command line
35. ut Control Unit RCU The RCU is responsible for reading out the front end electronics The RCUs is situated just outside the PHOS module and is connected to 28 front end cards situate inside the module A total of four RCUs is necessary in order to read out one PHOS module Before reading out data the RCU must know which channels to read out the front end cards must know how many samples to take for each event trigger In addition the PHOS Monitoring and Safety Module PCM of each of the cards must know which APD bias DAC settings to apply The configuration of the FEECs is the responsibility of the RCU The RCU receives the FEE configuration from the PABC GUI via a DIM server feeserver running on the DCS card and it is the responsibility of the RCU to apply these settings to the electronics 1 1 2 DCS card The DCS card is a mezzanine card that is connected directly to the RCU The task of the DCS card is to configure the RCU to tell the RCU which trigger input to use etc and to give the RCU the configuration of the FEE The DCS card includes a FPGA with an embedded arm processor The arm processor on the FPGA runs under a Linux operating system Busy Box This makes it possible to communicate with the DCS card via Ethernet From the point of view of the network the DCS card looks like any other PC 1 1 3 Distributed Information Management DIM Most of the information given about DIM in this section is taken unmodified from 1 The PHO
36. ver is the DIM DNS node and the other four are the servers running on the DCS cards The DID display should look as shown in Figure 2 1 2 5 Starting the APD GUI The DIM client To start the PABC bias control GUI do the following any machine gt ssh phos alphspcdcs01 cern ch phos alphspcdcs01 s password phosbeamtest alphspcdcs01 home phos gt dcs_cern sh sets up the enviroment 15 5 Servers known 46 Services Available Displaying ALL Servers Figure 2 1 The DIM Information Display DID alphspcdcs01 home phos gt cd phos_dcs alphspcdcs01 home phos gt apdgui 16 Chapter 3 Using the PABC Graphical User Interface apdgui This chapter gives an explanation on how to use the various options of the APD bias control GUI It is assumed that the communication chain is already set up and working 3 1 Starting the PABC Graphical User interface Log in to alphspcdcs01 cern ch with user phos and password phosbeamtest Make sure that the feeservers and the DIM DNS server are running see Chapter 2 2 and 4 9 for details Before starting the PABC GUI you must set up the environment variables alphspcdcs01 home phos gt dcs_icern sh To start the GUI do alphspcdcs01 home phos gt cd phos_dcs alphspcdcs01 home phos phos_dcs gt apdgui 3 2 Actions of the PABC program at startup When the PABC is started see section 2 5 it performs the following actions e It initializes a feecli
37. ver_start sh 4 8 Check if the feeserver is running First log in tho the DCS card where you want to check if the feeserver is running see Section 4 7 On the command line of the DCS card type the command ps a alphsdcsXXXX ps a 27 This will write out the complete list of processes running on the DCS card the a means all The list will look something like the one below If the feeserver is run ning there will be three processes associated with it You should have under the column Command three entries with the name bin feeserver If you started the feeserver with the startup script the normal way there will also be an entry called bin sh home phos feeserver_start sh The list of processes will look something like the one below PID ONOoOFRWN KE CONN WNDWW W DOA nTt VGEH0 oOo A 113 116 125 971 972 973 974 982 984 1010 Uid root root root root root root root root root root root root root root root root root root root root root root root root root root root VmSize 356 340 296 396 360 908 352 360 348 216 416 1180 428 372 384 384 384 1160 416 340 Stat Command S SW SWN SW SW SW SW SWN AMNNNNNNNNNNNNNNNN N init keventd ksoftirqd_CPUO kswapd bdf lush kupdated mtdblockd jffs2_gcd_mtd3 sbin syslogd m 0 0 var log messages sbin klogd sbin devfsd dev udhcpe b usr local sbin sshd D usr sbin inetd
38. word phosbeamtest alphspcdcs01 home phos gt 4 12 Check if the DIM DNS server is running On the command prompt of the PC alphspcdcs01 type the command ps e You will get long list of processes that looks someting like the list below not all the processe Lalphspcdcs01 home phos gt ps e PID TTY TIME CMD 1 00 00 05 init 2 7 00 00 00 migration 0 37 00 00 00 migration 1 perri more processes 2982 00 00 00 rpciod 2986 00 00 00 rpc mountd 2995 00 00 00 dhcpd the e stands for every process running on the PC as opposed to the option a that means allprocesses exept session leaders and processes not associtated with a terminal 31 3015 00 00 05 sendmail 3024 00 00 00 sendmail 3034 00 00 04 gpm 3043 7 00 00 00 crond 3066 7 00 00 00 xfs 3083 00 00 00 atd 3111 00 00 28 dimNameServer 3114 tty1 00 00 00 mingetty 3115 tty2 00 00 00 mingetty EEEE more processes If the DIM DNS server is running there should be either a process with the name dimNameServer or with the name dns If the DNS server was stared as it should automatically the name will be dimNameServer and if it was started manually from the commandline it will have the name dns In this examples the DNS server is running with PID 3111 4 13 Start the DIM DNS server To start the DIM DNS server you need to first log in to the PC alphspcdcsp1 You must run a script to set up the environment From the command prompt do the followi
39. ype or PHOS type The mapping of the power on lines of the GTL bus is different for TPC and PHOS After a reset the register telling which type of RCU register 80009 is set to the default value which is TPC Unless ALL FEEC is powered ON when resetting the RCU the APD settings will be gone and the FEEC APD bias settings must be reconfigured If all FEECs is turned on when disarming the trigger then it does not matter if the mapping is changed during reset and the settings of the FEECs is not lost Readout Configuration In the readout configuration menu the user specifies the num ber of samples the number of pretrigger samples to use The readout region specifies the matrix of crystals to read out The Z axis is horizontal and the X axis is vertical Origo 0 0 is in the upper left corner and the coordinate 55 63 is in the bottom right corner 23 of the PHOS module as seen from the back looking at the electronics Changes made in the Readout configuration menu takes effect when the user clicks the Arm Trigger button If you want to retrieve the readout configuration automatically the next time you open the PABC GUI then click the save button 3 3 7 The LogViewer The LogViewer display various messages from the system as response to user actions The messages shown in the Log Viewer is also written to the file home phos phos_dcs log tat 24 Chapter 4 PABC How To 4 1 Turn ON OFF a FEEC To turn ON OFF a FEEC simply