Home
ME.80-14/6ASW-PK BATTERY CHARGER/POWER SUPPLY USER
Contents
1. Battery deep discharge The device charges the battery automatically according to I U characteristic there is no need to any intervention In case of mains power cut the device prevents the deep discharge or failure of the battery by switching off the load at below 10 5V battery voltage 2 Power supply Application example supply of 12VDC cameras Connect the mains voltage to the input connector 230V 50 60Hz Adjust the output voltage by potentiometer installed inside the device to 12V measured by a multimeter Use the connector DC OUT and or BATT Max loading current is 6A The meaning of the STATE signal Continuous green Output is OK Continuous red Output is overloaded The signal alters from green to red if the output voltage run under 11 VDC Specifikations Input 230V 50 60Hz 10 Output voltage 12V 13 8V Output current 6A Insultation class I Protection IP 00 Max ambient temperature 50 C
2. ME 80 14 6ASW PK BATTERY CHARGER POWER SUPPLY USER MANUAL WARNING This device like all electrical products MUST be treated with respect Follow these instructions to reduce electrical hazard risk The device MUST be grounded to reduce risk of electrical shock Input and output connectors and indicator of the device AC IN 230V 50 60Hz L N STATE BATT 0 DC OUT 0 Usage of the device The device operates either as a battery charger or as a power supply You can choose the operating mode by setting of the nominal output voltage by a potentiometer installed inside the device The adjusted nominal voltage has to be measured by a multimeter If the nominal voltage is under 12 5 VDC the device operates as a power supply there is no deep discharge above 13 VDC it operates as a battery charger 8 1 Battery charger Contact the output BATT to the battery and output DC OUT to the load The output voltage is 13 8 V at both contacts max output current is 6 A At the design of the load please pay attention to the current of the charger this is determined by the loadability of the charger The total load at the outputs BATT and DC OUT can be max 6 A Pay attention to the right polarity Plug the mains voltage to the input contact AC IN 230V 50 60Hz The meaning of the STATE signal Blinking green Mains and battery voltage is OK Bilking green red Mains voltage failure in battery mode Blinking red
Download Pdf Manuals
Related Search
Related Contents
Gato FM-2 user manual Page 1 Page 2 の A2277 仕様書のとおり ご出負 担当官 ー業務用 Hand Vacuum Pumps Conceptronic 3.5" Female Jack to 2x Male RCA Adam Equipment 9618 Revision D Humidifier User Manual Benq MS517 TEFAL BL1261KR Instruction Manual 使用説明書 Ficha Técnica 4411 Monarch Specialties I 2550 Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file