1. 12843 Foothill Blvd Suite m ifornia 91342 V 818 898 3380 818 898 3360 Model No SW32PS RCP RS422 PORT SWITCHER REMOTE CONTROL PANEL User Manual Rev 1 01 TABLE OF CONTENTS REVISION HISTORY 2 GETTING STARTED 3 1 DESCRIPTION 3 2 INSTALLATION 3 3 CONNECTION DIAGRAM 4 4 OPERATION 5 a MAKE A ROUTE 5 b VIEW THE ROUTES 5 c DISCONNECT ROUTE 5 d SAVE PRESET 5 e RESTORE PRESET 5 f SETUP GANG 6 g DISCONNECT GANG 6 5 SELF TEST PROCEDURE 7 a KEYBOARD TEST 7 b SYSTEM PORT TEST 7 REFERENCE 9 6 SPECIFICATIONS 9 POWER CONNECTOR 9 RS422 SERIAL CONNECTOR 9 CONNECTOR 10 7 FRONT PANEL LAYOUT 11 8 DNF CONTROLS LIMITED WARRANTY 13 Manual Version susana 1 01 090407 Document aanunnnnnnnnnnnnnnnnnunnunr SW32PS RCP User Manual doc SW32PS RCP Port Switcher Controller Page I of 13 1 REVISION HISTORY 080505 1 0 Original document 090407 1 01 Corrected 10 Switch numbering Page 2 Of 13 SW32PS RCP Port Switcher Controller Getting Started 2 DESCRI PTI ON The control panel consists of the ST100 controller hardware and the special software that allows controlling the SW32PS for the following functionality Make route view routes gang outputs to input disconnect route disconnect gang save preset restore preset Easy to read LCD Display has 2 lines by 20 characters Shows source From and destination To routing and gang information 6 function keyp
2. Use the table below to set the switches for the desired ID SW6 SW5 SW4 SW3 sw2 Sw1 ID 01 Left Left Left Left Left Right 1D 02 Left Left Left Left Right Left 1D 03 Left Left Left Left Right Right ID 04 Left Left Left Right Left Left 1D 05 Left Left Left Right Left Right ID 06 Left Left Left Right Right Left ID 07 Left Left Left Right Right Right 08 Left Left Right Left Left Left ID 09 Left Left Right Left Left Right ID 010 Left Left Right Left Right Left Connect DB9F side of supplied power supply into the connector labeled Power Then connect the IEC to Edison cable to the power supply Connect the power cable to 90 VAC to 240 VAC source Caution Do Not Hot Plug the Power Supply DB9F connector Installation is complete 4 CONNECTION DIAGRAM POWER SUPPLY PORT EXPANDER 5 VDC 1 AMP 90 VAC 255 Adapter included SW32PS RCP TYPICAL CONNECTION DIAGRAM Page 4 Of 13 SW32PS RCP Port Switcher Controller 5 OPERATION a MAKE A ROUTE 1 Press FROM The FROM indicator will turn on The left side of the display shows the currently selected FROM connector PORT1 32 2 Turn the Wheel until the desired FROM point is displayed 3 Press TO The TO indicator will turn on The right side of the display shows the currently selected TO connector PORT1 32 Turn the Wheel until the desired TO point is disp
3. ad provides From Select Source To Select Device View View active router Take Enable the selected route Gang User control of multiple destinations Preset Select Preset Ideal for Television Stations Video Productions Cable TV Video Post Production Duplication Houses NOTE Words enclosed in brackets such as TAKE indicate buttons on the SW32PS RCP Buttons shown with a between them for example SHIFT TAKE indicate two keys pressed simultaneously 3 1 NSTALLATI ON a Plug one end of a 9 pin cable into the connector labeled VTR on the back of the controller Plug the other end into one of the connectors on the port expander Plug the port expander into the connector labeled RS422 on the back of the SW32PS port switcher Dip Switches Configuration for SW32PS RCP Every SW32PS RCP has to have a unique ID from 1 to 10 The ID should match the External Device number set in the SW32PS For example if you use only one SW32PS RCP with the SW32PS the External Device should be set to 1 and the ID of the RCP should be 01 The ID can be seen on the second line of the display during the power up of the RCP If you use two SW32PS RCPs with the SW32PS the External Device should be set to 2 and the 10 of the RCPs should be 01 and 02 The 105 can be seen the second line of the display during the power up of the RCP SW32PS RCP Port Switcher Controller Page 3 13
4. cator turns on The right side of the display shows the currently selected TO connector PORT1 32 4 Press GANG The GANG indicator turns on 5 Turn the Wheel to select the destination port 6 Press TAKE to route the selected input to the selected destination The second line of the display will show PORT X Added 7 Repeat steps 5 6 to add additional routes to GANG 8 Press ESC when done FROM TO and GANG indicators turn OFF NOTE The GANG function will only work properly if the GANG is Enabled on the SW32PS It is the responsibility of the user to set GANG to Enabled in the SW32PS Setup Menu See the SW32PS Port Switcher User Manual for the instructions on how to enable disable gang 9 DISCONNECT GANG 1 Press VIEW Turn the Wheel to find the GANG to be disconnected Press GANG The display will prompt Disconnect switches Press TAKE to break all the routes that are part of gang OR Press ESC to exit WN Page 6 Of 13 SW32PS RCP Port Switcher Controller 6 SELF TEST PROCEDURE o Press TAKE PRESET SHIFT in that order to enter test mode Press TAKE PRESET SHIFT at anytime to exit self test mode a KEYBOARD TEST Press keys to see the appropriate scan code on the display Turn the Wheel to see Wheel count on the display change FO 00 10 b SYSTEM PORT TEST Plug an RS422 looping plug into RS422 connector on the back of the SW32PS RCP The disp
5. incipally UPS Ground for shipments within the United States of America Shipments to international customers will be sent via air Should a customer require the product to be returned in a more expeditious manner the return shipment will be billed to their freight account This warranty will be considered null and void if accident misuse abuse improper line voltage fire water lightning or other acts of God damaged the product All repair parts are to be supplied by DNF Controls either directly or through its authorized dealer network Similarly any repair work not performed by either DNF Controls or its authorized dealer may void the warranty After the warranty period has expired DNF Controls offers repair services at prices listed in the DNF Controls Price List DNF Controls reserves the right to refuse repair of any unit outside the warranty period that is deemed non repairable DNF Controls shall not be liable for direct indirect incidental consequential or other types of damage resulting from the use of the product HEHE SW32PS RCP Port Switcher Controller Page 13 of 13
6. lay should say port OK Unplug the 5422 looping plug SW32PS RCP Port Switcher Controller Page 7 of 13 USO RESTRITO Page 8 Of 13 SW32PS RCP Port Switcher Controller REFERENCE 7 SPECI FI CATI ONS SW32PS RCP Power Requirements 90 VAC to 265 VAC adapter supplied with IEC connector Power Supply 5VDC Size L x W x H 19 8 5 1 75 1RU Weight 4 Ibs Rear Panel Connectors GPI D26HDF RS422 D9F Power D9M Display 2 Line x 20 Character LCD display back lit Data Entry Wheel POWER CONNECTOR 9 Pin D Type Male Pin 1 5v DC 6 NC 2 NC 7 NC 3 Ground 8 NC 4 NC 9 NC 5 NC RS422 SERIAL CONNECTOR 9 Pin D Type Female Pin 1 Frame Ground 6 Receive Common 2 Receive A 7 Receive B 3 Transmit B gt 8 Transmit A gt 4 Transmit Common 9 Frame Ground 5 Spare SW32PS RCP Port Switcher Controller Page 9 of 13 26HD Pin D Type Female DB26HDF Pin 1 Output 1 Function 2 Output 2 Function 3 Output 3 No Function 4 Output 4 Function 5 Output 5 Function 6 Output 6 Function 7 Output 6 Function 8 Output 8 Function 9 Ground 10 Input 1 No Function 11 Input 2 No Function 12 Input 3 No Function 13 Input 3 No Function 14 Input 4 No Function 15 Input 5 No Function 16 Input 6 No Function 17 Input 7 No Function 18 Ground 19 5v 20 5v 21 No Connection 22 No Connection 23 No Connectio
7. layed 4 Press TAKE to route the FROM input to the TO output NOTE No Route is made until TAKE is pressed NOTE The Route that involves the selected FROM and or TO will be disconnected prior to making the new route b VIEW THE ROUTES 1 Press VIEW The VIEW indicator will turn on 2 Turn the Wheel to scroll through all ports that are displayed on the first line of the display DISCONNECT ROUTE 1 Press FROM 2 Turn the Wheel until OFF is displayed 3 Press TO 4 Turn the Wheel to find the destination that you wish to turn off 5 Press TAKE to turn off the route d SAVE PRESET 1 Press SHIFT PRESET The PRESET indicator will turn on The first line of the display will show Save Preset 1 2 Turn the Wheel to select preset number 1 8 3 Press TAKE to save current configuration into the selected preset OR Press ESC to exit without saving RESTORE PRESET 1 Press PRESET The PRESET indicator will turn on The first line of the display will show Restore Preset 1 2 Turn the Wheel to select preset number 1 8 3 Press TAKE to restore selected preset OR Press ESC to exit without restoring SW32PS RCP Port Switcher Controller Page 5 of 13 f SETUP GANG 1 Press FROM The FROM indicator turns on The left side of the display shows the currently selected FROM connector PORT1 32 2 Turn the Wheel to select the source port 3 Press TO The TO indi
8. n 24 No Connection 25 No Connection 26 Ground Page 10 Of 13 SW32PS RCP Port Switcher Controller 8 FRONT PANEL LAYOUT SW32 RCP Front Panel SW32PS RCP Port Switcher Controller Page 11 of 13 USO RESTRITO Page 12 Of 13 SW32PS RCP Port Switcher Controller 9 DNF CONTROLS LI WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one 1 year from the date of sale to the original purchaser from DNF Controls In order to enforce the rights under this warranty the customer must first contact 5 Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair If DNF s Customer Support Department cannot fix the problem the customer will be issued a Returned Merchandise Authorization number RMA The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer s shipping document The merchandise 15 to be shipped to DNF Controls 12843 Foothill Blvd Suite C Sylmar CA 91342 USA Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted or in a charge for the required repair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls pr