1. enter alarm record page the latest record will be shown on first item All alarm records the current record the alarm type alarm time and the address of monitor will be displayed If the system has no alarm records it will show have no record Press Page Up to see last page alarm records and press Page Dn to see next page alarm records Press one of alarm record item to enter alarm status page then press Dial icon to call the current monitor If the user answers the call the guard person can talk with the user immediately The system will cut off automatically if exceeds the maximum calling waiting time in calling state or exceeds maximum talking time in talking state Checking all calls record On main menu page of Guard Unit touch Event gt Missed calls all calls that has not been answered will be shown Touch Event gt All calls all calling records the latest calling record the call type call time and the address will be displayed and If the system has no calling records it will show have no record Press Page Up to see last page calling records and press Page Dn to see next page calling records Press one of calling record item then press Dial icon to call the current monitor or door station The calling is the same as Guard Unit calls monitor or door station The system will cut off automatically if exceeds the maximum calling waiting time in calling state or exceeds maximum talking
2. VIDEO INTERCOM SYSTEM USER MANUAL se VO IP G21 Version 1 0 120308 1 Parts and Functions LCD Screen A et Microphone Handset Pa cer Alarm Button Speaker 04 Unlock Button wOA 7 Call Button Handset Line Dimension 220 H x 358 W x 35 D mm Key functions Microphone Receives sound from the user LCD Screen Display the icon menu and images Touch operation Alarm Button Flash when the guard unit receives alarm record 1 Red indicator flash first green indicator flash later when power on 2 Blue indicator ormally on when work in normal LED Indicator 3 Blue indicator flash when in calling state 4 Red indicator flash when in talking state Speaker Output sound from the visitors or users Handset Line Connect guard unit with handset 2 Specification Power supply DC 14 30V Power consumption Standby 6W Working status 13W Working temperature 10 C 55 C Alarm record 1000 pieces Calls record 600 pieces Screen 10 inch digital TFT LCD Video signal 1Vp p 750 CCIR standard Wiring CAT5 cable Dimension 220 H x 358 W x 35 D mm 3 About Main Menu The Main menu is your starting point for using a
3. al User Soft and Bright Whenever you modify Brightness or colour Scene item will be set to User mode automatically e The Brightness and Color item is for the image quality setting adjust the value to get the best image you like The Talk Volume item is for talking volume adjustment Note that all the modifications will be performed immediately after the operation Please read this manual carefully before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice
4. f buzzer and the alarm button will flash in red when receives alarm signal At the same time the address of the monitor will be shown on screen The latest alarm record will be displayed on first item Press one of alarm record to enter alarm status page the buzzer will stop ringing and the alarm indicator will stop flash At alarm status page press dial icon to call back the current monitor If the user answers the call the guard person can talk with the user immediately The system will cut off automatically if exceeds the maximum calling waiting time in calling state or exceeds maximum talking time in talking state Entrance monitoring On main menu page touch Manual Monitor icon to open monitor page Input the address of door station by touching digital keypad on guard unit for example to monitor the 1st door station of B block you should input B 1 then touch Monitor icon to monitor during inputing press key to cancel Monitoring door station or common door station by list is also available on monitor page press list icon touch one item then touch monitor icon to see conditions of door station If the number is correct monitoring is activated immediately when the door station is free During monitoring press unlock icon to release the door The system will cut off automatically if exceeds maximum monitor time Checking alarm records for monitor On main menu page of the Guard Unit touch Event gt Alarm record to
5. g during inputting press key to cancel If the room number is error the guard unit will send out Di Di Di and a message of calling fail will be shown If the user answers the call the guard person can talk with the user immediately The system will cut off automatically if exceeds the maximum calling waiting time in calling state or exceeds maximum talking time in talking state Calling door station or common door station On main menu page touch Intercom icon or press Call button in standby mode on Guard Unit to open intercom page Input the address of door station by touching digital keypad on Guard Unit for example to call the 1st door station of B block you should input B 1 then touch dial icon to activate the calling during inputting press key to cancel Calling door station or common door station by list is also available on intercom page press list icon touch one item then touch dial icon to call If the number is correct calling is activated immediately when the door station is free the guard unit can talk with outdoor During talking press unlock icon to release the door The system will cut off automatically if exceeds the maximum calling waiting time in calling state or exceeds maximum talking time in talking state User alarms to Guard Unit Select Call Guard Unit on monitor to alarm guard unit please refer to monitor user manual for more detail information The Guard Unit will send out a soud o
6. ll the applications on the guard unit To open the main menu page touch the LCD screen anywhere twice 4 Operation Instructions Answer calls from door station Input 0000 on door station to call guard unit The Guard Unit rings and the red LED indicator flash the vistors image and the address of the door station will be shown on screen Note that the screen will be turned off in limited time if nobody answers If the guard person answers the call talking with outdoor is available During talking state press unlock button to release the door If the guard unit is busy calling from door station is unavailable Answer calls from common door station The operation is the same as calling from door station Answer calls from users Select Direct call guard unit on monitor to call Guard Unit please refer to monitor user manual for more detail information The Guard Unit rings and the red LED indicator flash the address of the monitor will be shown on screen Note that the screen will be turned off in limited time if nobody answers If the guard person answers the call talking with user is available Calling users On main menu page touch Intercom icon or press Call button in standby mode on Guard Unit to open intercom page Input block and room number by touching digital keypad on Guard Unit for example the block is 124 the room number is 0001 you should input 124 0001 then touch dial icon to activate the callin
7. s default If receive a call after a moment the guard unit will record automatically one picture will be taken for each calling or you can touch Capture icon to record the visitor s image manually Picture playback On main menu page touch Event gt Memory Playback 4 pictures will be displayed in the memo for each page you can touch Page up or Page down icon to view last or next picture memo or touch Delete all icon to delete all pictures And you can view the pictures on full screen by touch Full icon on full screen mode touch Last or Next icon to preview last next picture or you can touch Delete icon to delete the current picture you are previewing press Home icon to return main menu page Note The captured pictures will be saved in a folder named by date e The captured pictures in the built in memory can be copied to the SD card and you should use T views memo software tool to convert the pictures to JPG format that can be seen on the computer When the built in memory is full the oldest picture will be deleted to make room for new record Avoid to plug in out the SD card when the guard unit is under operation Playing will be interrupted by the calling 8 Screen and Volume Adjustment During monitoring or talking touch ADJUST icon then touch and select the adjustment item you want touch icon to decrease increase the value e The Scene mode selection Total 4 screen modes can be selected in sequence Norm
8. t the digit press key to save the settings The date format can be set to DD MM YY or MM DD YY touch Date Format icon to switch date format setting The time format can be set to 24 hours or 12 hours format touch Time Format icon to switch time format setting To see the current date and time touch the screen anywhere once in standby mode to open the calendar page or enter the status bar Monitor time setting Touch User Setup icon on main menu page then touch Monitor Time Set a digital keypad will be shown on screen Input the monitor time by touching the digital keypad press key to select the digit press key to save the settings Change password A password will be asked before enter Menu Upgrade Event clear and Restore to default page the default password is 1234 Touch User Setup icon on main menu page then touch Password Setup a digital keypad will be shown on screen Input the old and new password by touching the digital keypad press key to select the digit press key to save the settings 7 Built in Memory and SD Card The Guard Unit has been equipped with a built in memory about 120 MB together with a SD card reader Maximum 16 GB SD card can be supported SD card Co gt Picture recording Both auto recording and manual recording are available and auto recording i
9. time in talking state Clear all call records and alarm records On main menu page touch Event gt Event clear A password will be asked Input the password by touching the digital keypad 1234 is the default password the password can be modified at any time All call records and alarm records will be cleared 5 System Tools Touch User Setup gt System Tools on main menu page of the Guard Unit a password will be asked 2412 is the default password Input the code number by touching the digital keypad press key to select the digit press key to save the settings When enter the setting page the IP address of the Guard Unit can be set Each guard unit should be assigned with one IP address in IP system Input code number of 2108 by touching the digital keypad then input IP address the range is from 247 254 6 Settings Ring tone setting User call tone door station call tone GL call tone can be set different ring tone to distinguish different calling Touch User Setup icon on main menu page then touch Call Tone Setup total 6 pieces ring tones will be displayed Touch Ring Type icon to switch to set User call tone door station call tone GL call tone Touch Louder Volume to select a louder ring tone volume Date and time setting Touch User Setup icon on main menu page then touch Clock a digital keypad will be shown on screen Input the date and time by touching the digital keypad press key to selec