Home
LINDA U06/U12 Battery Charge Indicators User Manual
Contents
1. raftec PRAF MICROCOMPUTER TECHNOLOGIES LTD St Kugel 40 P O B 7209 Holon 58171 Israel O Tel 972 3 5031045 Fax 1 586 4614268 http www praftec com E mail info praftec com DOC REF NAME LINDA UM 102 LINDA U06 U12 Battery Charge Indicators User Manual Rev 1 02 7 December 2004 Last modified June 3 2005 Technical Specifications Input voltage V U06 8 3 U12 16 5 Charged batteries type U06 6V rechargeable acid battery U12 12V rechargeable acid battery Threshold Voltage V U06 6 9 U12 13 8 Maximum Charge Current A 5 Maximum Dropout Voltage V 0 3 Dimensions L x W x H mm 60mm x 35mm x 22mm PRAF Microcomputer Technologies Ltd LINDA UM 102 Page 1 of 4 raftec PRAF MICROCOMPUTER TECHNOLOGIES LTD St Kugel 40 P O B 7209 Holon 58171 Israel i O Tel 972 3 5031045 Fax 1 586 4614268 http www praftec com E mail info praftec com 1 Introduction LINDA U06 U12 modules are intended to monitor the process of acid battery charging and to indicate status of the charging process with Light Emitting Diodes LED 2 Technical Description The LINDA U06 U012 module is housed in small plastic cabinet that has Power Cable Terminal 1 Battery Cable Terminal 4 Power LED Indicator 2 Charge LED Indicator 3 as shown on the picture below rc 3 Operation Instruction The LINDA module should be connected between charger and charged battery as shown on the picture below and in
2. accordance with the following instruction p E HU o Ho CHARGER ACID BATT L I a Verify that used LINDA module is suitable for battery that is going to be charged and that the charger is corresponding to the battery LINDA U06 model must be used with PRAF Microcomputer Technologies Ltd LINDA UM 102 Page 2 of 4 raftec PRAF MICROCOMPUTER TECHNOLOGIES LTD St Kugel 40 P O B 7209 Holon 58171 Israel O Tel 972 3 5031045 Fax 1 586 4614268 http www praftec com E mail info praftec com 6V acid battery and respective charger and LINDA U12 must be used with 12V acid battery and respective charger b Connect Battery Cable Terminal 4 to the battery c Connect Power Cable Terminal 1 to output terminal of the charger d Plug the charger to AC power mains in e As soon as the charger is plugged in the AC power mains the Power LED Indicator 2 will be lighting indicating presence of power and the Charge LED Indicator 3 will be lighting indicating the battery charging process f The Charge LED Indicator 8 will stop lighting as soon as charging process is completed 4 Troubleshooting 4 1 PWR and CHQ indicators are off a Improper and or damaged charger is used b Charger is not properly plugged in AC power mains c Charger is not properly connected to LINDA module 4 2 PWR indicator is ON and CHG indicator is OFF while discharged battery is connected a LINDA module
3. ect special or exemplary incidental punitive or consequential damages of any kind in connection with this document or the information contained herein in connection with use of or deal with the product even if advised of the possibility of such loss or damage Warranty In the event that the product proves to be defective within a period of one year from a date of shipment PRAFTEC shell repair or change the product at its discretion and all possible delivery services expenses will be covered exclusively by dealer distributor or user of the product The warranty will be void for malfunctions caused by fire accident neglect abuse improper usage applying an improper electrical power attempt to repair the product by anyone other than PRAFTEC authorized personnel praitec PRAF Microcomputer Technologies Ltd URL http www prattec com E mail info praftec com 40 Kugel St P O B 7209 Holon 58171 Israel Tel 972 3 5031045 Fax 1 586 4614268 PRAF Microcomputer Technologies Ltd LINDA UM 102 Page 4 of 4
4. is not properly connected to the battery b The charged battery is damaged 4 3 The LINDA module indicates that charging is completed but the battery does not work properly after charging a The battery is damaged b Capacitance of the battery is too low 4 4 CHG indicator is ON and does not getting OFF even after 15 18 hours the battery of charging a The battery is damaged or is in loss of its nominal parameters PRAF Microcomputer Technologies Ltd LINDA UM 102 Page 3 of 4 raftec PRAF MICROCOMPUTER TECHNOLOGIES LTD St Kugel 40 P O B 7209 Holon 58171 Israel O Tel 972 3 5031045 Fax 1 586 4614268 http www praftec com E mail info praftec com 5 Legal Notes This document refers to the LINDA U06 U12 Battery Charge Indicator as the products operation manual intended to help its users to use the unit Copyright Notice Copyright PRAF Microcomputer Technologies Ltd 2005 All rights reserved All the trademarks if mentioned herein are property of their respective owners Disclaims PRAF Microcomputer Technologies Ltd PRAFTEC continuously works in order to improve the LINDA U06 U12 performance and features This document and any features of the unit including hardware and software of the product are subject to be changed without prior notice In no event shall PRAFTEC be liable to any party for any loss of profits loss of business loss of use of data interruption of business or for direct indir
Download Pdf Manuals
Related Search
Related Contents
Smokin' Token Xtreme Service Manual Samsung ProXpress M4075FX Monolaser Multifunktionsgerät Benutzerhandbuch Untitled ventilacion Samsung Samsung L770S User Manual Manual de ayuda - Ministerio de Ciencia e Innovación PDF 施工要領書 PS 1000 (JA), 1.9 MB Service Manual Copyright © All rights reserved.
Failed to retrieve file