Home
Heatmiser Plusnet v1.00
Contents
1. FROM MONDAY WEEKDAYS Send Once you have made the necessary adjustments you must press Send in order to update the Heatmiser Plus Override Hold Function Plusnet allows you to override each zone For zones with comfort levels you can set a desired temperature and override time For timer zones you can enter the override time Highlight the zone by clicking on the zone name Right click the zone name Click Override You can now enter the override duration and temperature For timer zones you will be prompted to enter an override duration only e Press Confirm Heatmiser PlusNet User Manual Page 5 Holiday The Heatmiser Plus offers 5 holiday periods During a holiday condition the Plus will maintain the System Frost Temperature which can be adjusted from Plusnet see page 08 e To adjust the holiday setting use the calender to select the start date and then enter the number of days for the holiday e Press Send to send the new settings to the Heatmiser Plus Start Date 02 07 2008 0 Day July 2008 Won Tue Wed Thu Fri Sat Sun 3 4 45 yr 8 4 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 0 Today 02 07 2008 Temperature Log The Plusnet server stores the temperature log for the past 1 year The past 7 days can be viewed quickly via the Plusnet interface in the form of a line chart This function allows you to quickly determine which zones are us
2. Heatmiser Plusnet v1 00 User Instructions Rev 1 Jan 2009 Heatmiser PlusNet User Manual Page I Table of Contents Description Page Number Selecting the Site and Zone you wish to view 3 Programming the Comfort Levels Switching Times Copy Function Override Function Holiday Function Temperature Log Hours Run Exporting Hours Run Log Data Setting the System Frost Setting up Systems Users O COI N NOAOA SB Heatmiser PlusNet User Manual Page 2 Site List Zone List To the left side of the screen is the Site and Zone Zone List From here you can select which site you want to connect to and which zone you want to view When you click on the site you will see the site drawing appear along with the sensor and relay indications relevant for the selected zone is PlusNet w1 00 A X PlusNet File Export Setup Location Test Test Zone List ee Boiler Set Boiler Temp Pump Status Boiler Outputs ae Message Server Online FENER so Heatmiser PlusNET 1 COM_Communication 4 Untitled1 OpenOffic Main Overview PlusNet automatically adjusts the Main Overview display depending on the configuration of the zone being viewed As an example the picture shown below shows a typical layout Actual Boiler SetBoilerTemp Pump Status Boiler Outputs 22 C 80 C ON 12 Heatmiser PlusNet User Manual Page 3 Switching Times
3. The Heatmiser Plus uses Comfort Levels and Timer On Off Settings Comfort levels are programmed different than normal On Off times With a comfort level you program atime and the temperature you want at that time To adjust the setting simply type over the existing data You can use the TAB key for easy data entry You have the option to program 4 comfort levels for each day of the week You should use the disable function to disable the switching periods that are not required For timer zones you should program these as On Off times these zones do not rely on a set temperature Plusnet will auto detect the zone configuration and will display the appropriate display Comfort Leveld 08 00 Comfort Level 2 17 00 04 Enable Disable Comfort Level 3 00 00 EnableDisable Comfort Level 4 oa 00 Enable Disable Comfort Levels On Ont Timet Timed Enable Disable Times Enable Disable Timed Enable Disable Timer On Off Heatmiser PlusNet User Manual Page 4 Copy Plusnet enables to you copy comfort levels from one day to another To use the Copy function repeatedly press the COPY FROM DAY until the day you want to copy from is shown Then repeatedly press the COPY TO DAY until the day you want to copy to is shown Note you can also select to copy to all weekdays or to all days When you are happy with the setting press Yes to copy the data COPY COPY TO FROM DAY DAY ARE YOU SURE YOU WANT TO COPY ALL TIMES
4. e 7 e Choose the export path and enter a file name for the file to be exported Press Export When you import into MS Excel you need to select Comma Delimited as an import option Setup Menu Administrator Only System Frost The system frost temperature setting is a global setback temperature and is used to maintain a temperature during a holiday period The system frost temperature can be set from 00 35C User Setup This option allows you to add new users to the system and provides the ability to assign access rights to each user New user with User Rights Is allowed to view and edit zone switching times override zone set temperature and view history data but is not allowed to add or remove sites from the system New user with Admin Rights Has full access to the system including site configuration Heatmiser PlusNet User Manual Page 8
5. ing More energy therefore helping you to reduce your overall energy consumption Heatmiser PlusNet User Manual Page 6 a SPS SESE 98 8 os Sess SSE SEES Ci aa gs a ti ri s Pes a S ON Hours Run The Heatmiser Plus stores the Hours Run for the past 3 weeks This information is displayed as a bar graph and like the temperature log helps you determine areas of high energy usage Site Setup This option is available to the System Administrator only See Setup Manual for details File Menu Print This menu allows you to print the temperature and hours run graph Backup Database This backup utility allows you to make a backup of all sites stored in the database We suggest that you run this backup after a new site has been added to the system Upgrade Database This upgrade utility allows you to restore the database from the backup Export Menu Export Hours Run This option allows you to export the hours run data in csv format Export Temperature Log A temperature export function is available This function allows you to export the temperature history for a selected date range and then use MS Excel to create a line graph showing the history over an extended duration To export the temperature log follow the steps below Press Export Select Temperature Log and then select the zone you wish to export On the calender select the From date On the calender select the To date Heatmiser PlusNet User Manual Pag
Download Pdf Manuals
Related Search
Related Contents
Manual d`instructions 07.10.2008 Également pour les modèles avec CPC805 User Manual v.001 E Pre User manual AirSpace CCTV COLOSO 3D Lens Filter TCP/IP に係る 既知の脆弱性 検証ツール Hoja de información de producto Deb® Natural User Manual - PICASSAU ロボット掃除機 MC9500-K Mobile Computer User Guide [German] (P/N 72E Copyright © All rights reserved.