1. Frequency 80 Hz Pulse width 150 us Therapy time 30 min 10 to 90 min Indications Acute nerve or joint pain Program 2 is similar to program 1 but works with a lower frequency and may therefore be considered as more pleasant Program 3 Low frequency Both channels work with the same frequency and pulse width see illustration Program 1 Frequency 2 Hz Pulse width 250 us Therapy time 30 min 10 to 90 min Indications Diffuse nerve joint or muscle pain spasms lower back pain neck pain fibromyalgia chronic pain This program is used to relax painful muscles and to achieve an endorphin release Endorphins have an analgesic effect that lasts beyond stimulation but you need to run program P3 to the end 30 min To achieve particularly good effects use kaada electrodes placement on the hand Program 4 Gate control amp low frequency The channels work with different frequencies but with the same pulse width Therapy time 30 min 10 to 90 min Channel 1 Channel 2 Frequency 100 Hz Frequency 2 Hz Pulse width 200 us Pulse width 200 us Indication Joint pain This program combines the effects of program 1 and 3 in case the analgesic effect off program 3 is not strong enough Intensity Channel 2 Channel 1 Time schwa medico TENStem eco basic Program 5 Adaptation After phase 1 the program changes automatically to phase 2 Therapy time 30 min 10 to 90 min P
2. No Article Size Pair 107023 Stimulation socks M 1 107024 Stimulation socks L 1 TENStem eco Running program Parameters of Treatment time the program Intensity level ON OFF Stop Program choice Increase intensit Increase intensit Decrease intensit Decrease intensit NO 6 schwa medico Gate control 1 Gate control 2 Low frequency Gate control Program No low frequency Modulation Muscle stimulation Gate control dynamic 1 Gate control dynamic 2 Deep TENS TENS stimulation Muscle stimulation Gate control dynamic a D x e o D TENStem eco basic Indication Nociceptive pain acute pain neuropatic pain Alternative to program 1 Chronic nociceptive pain improvement of blood circulation Kaada stimulation Combination of high and low frequency stimulation Muscular pain Suitable for almost all kinds of pain program Alternative to program 3 more comfortable Alternative to the other programs in case of therapy resistance Atrophy prophylaxis muscle strengthening Muscle relaxation Muscle relaxation venous return Muscular pain deep seatted pain Pain treatment see programs 1 3 Muscular pain deep seatted pain Muscle relaxation lontophoresis nerv block Jenkner block stellate ganglion block 27 schwa medico TENStem eco basic Description Frequency Hz Pulse width us Both channels 1 1 14100 channels C
3. P16 Voltage Voltage Output Power Time Output Power Time Time Time change in output current depending on load Output Power mA lo 2 ge ee Resistance RL 500 1000 1500 2000 2500 Q 16 programs 12 pre set 4 for own settings Large LCD that shows Selected program Therapy time Intensity two separated channels Frequency Pulse width Automatic cut off after 2 minutes of no use Easy handling via keypad Battery level control Electrode recognition the intensity is reduced to 0 if no electrodes are connected or not properly connected The selected program can be interlocked Saving and read out of operating parameters schwa medico TENStem eco basic Description All parameters can be adjusted via the keypad and are indicated on the large display 1 Display 2 Menu keys 3 Modification keys to adjust parameters and intensities 4 ON OFF key 5 Battery compartment 6 Output sockets for the cables Keypad Ce to switch the device on and off and to stop stimulation P to select a program E to set the parameters A to increase the intensity left for channel 1 right for channel 2 W to decrease the intensity left for channel 1 right for channel 2 Operating the TENStem eco basic Starting the device Insert the batteries into the battery compartment no 5 Please also read the chapter Battery change for more information All symbols appear automatically on the display An
4. acoustic signal indicates that the unit is ready for use Connecting electrodes and cables First connect the 2 mm diameter male connectors of the cables red and white connector on each cable to the black female connectors of the electrodes always 2 electrodes per cable Connecting the cables to the TENStem eco basic Connect the white plug at the other end of the cable to the sockets on the upper front face of the TENStem eco basic no 6 You may use the device with one or two cables depending on the therapy J Switching ON the TENStem eco basic Program ON OFF Stop Intensity Intensity Channel 1 Channel 2 Setting date and time From series C Memory query mode schwa medico TENStem eco basic Press to switch ON the TENStem eco basic A double beep sounds The display indicates the selected program the therapy time the frequency the pulse width and the intensity Selecting a program Press P until you have selected the program of your choice Once you have reached P15 you will return to P1 Starting the stimulation setting the intensities Press the left A key to increase the intensity of channel 1 Press the right A key to increase the intensity of channel 2 Press the left key to reduce the intensity of channel 1 Press the right W key to reduce the intensity of channel 2 It is not possible to adjust the intensity of both channels at the same time Stopping the stimulation The stimulation sto
5. eco basic in its case to protect it from damage and dust To avoid reciprocal interference the TENStem eco basic should not be ope rated in the vicinity of other electronic devices If this is not possible the various unit functions should be closely monitored during operation so that proper use in accordance with the regulations is ensured The simultaneous connection to the patient of a high frequency surgical unit can lead to burning under the electrodes or around the probe Operating close for example Im to short wave and microwave units or mobile telephone systems can cause fluctuations in the output values of the electric current stimulation unit Do not use the machine during the simultaneous operation of other ma chines when driving or when asleep Do not use P16 for more than 20 minutes Contra indication schwa medico TENStem eco basic Please check with your physician before using the TENStem eco basic if one of these apply to you Side effects Symbols Patients with electronic implants such as heart pacemakers defibrillators Or pumps Patients with cardiac rhythm disorders During pregnancy Patients subject to seizure disorder epilepsy Patients with skin disorders in the vicinity of the electrodes Patients with malignant diseases in the region of application Pain caused by the stimulation The stimulation can be perceived as uncom fortable painful if the electric current is too intensive or if th
6. medico TENStem eco basic Intensity working time Time Program 10 Gate control dynamic 1 The intensity continuously changes and the two channels operate alternately massage effect Frequency 80 Hz Pulse width 150 us Intensity modulation 1s rise 1 s fall Therapy time 30 min 10 to 90 min Indications Especially for acute back pain lower back pain sciatic pain This program is recommended for the treatment of back pain The massage effect provides a comfortable and pleasant stimulation The so called Gate Control reflex which is achieved through this kind of stimulation is a natural reflex that you achieve e g by rubbing a painful area with your hands to calm acute pain To achieve the massage effect it is essential to use both channels of the TENStem eco basic Intensity Time Program 11 Gate control dynamic 2 The intensity continuously changes two channels operate alternately massage effect See illustration program 10 Frequency 80 Hz Pulse width 150 us Intensity modulation 0 25 s rise 0 25 s fall Therapy time 30 min 10 to 90 min Indications Heavy legs venous return Program 11 is similar to program 10 but the movement of the massage waves is faster It is used to Improve the venous return for patients who suffer from heavy legs To achieve the massage effect It is essential to use both channels of the TENStem eco basic 15 schwa medico TENStem eco basic Progr
7. pain spasms lower back pain neck pain fibromyalgia This program covers the same indications as program 3 but the stimulation is often considered as more comfortable and pleasant than the normal low frequency stimulation Pulses Time Program 8 Modulation The frequency continuously changes within the frequency limits The pulse width adapts accordingly Minimal frequency 2Hz Pulse width 200 us Maximal frequency 80 Hz Pulse width 100 us Modulation duration 7 5 s 2 Hz gt 80 Hz Therapy time 30 min 10 to 90 min Indications Acute nerve or joint pain as an alternative to P1 and P2 If you feel that the analgesic effect of program 1 or 2 is decreasing change to program 8 With frequency modulation the body does not become accustomed to the stimulation Program 9 Muscle stimulation The intensity continuously changes according to the indicated parameters Frequency 50 Hz Pulse width 250 us Rising ramp 28 Working phase DS Falling ramp 1s Pause 12 s Therapy time 30 min 10 to 90 min Indications Prevention of muscular atrophy muscle strengthening This program is suitable to maintain the muscle volume e g during injury or recovery or to avoid muscle atrophy In case of muscle atrophy do not stimulate more than once a day for the first month Certainly program 9 can also be used to strengthen a healthy muscle schwa
8. seconds and the device returns to nn LI LILI standby mode automatically If you have saved therapy data the display shows tiuj US the parameters of the last therapy session as shown below m Used program P01 Frequency 100 Hz A Pulse width 200 us Therapy duration 0 min 44 s Day of therapy 5 fifth day Therapy session no 3 You can save up to 90 therapy sessions respectively the first 3 of each day With the left W key you can return to the values of the previous day until you reach the first recorded day The left A key lets you proceed to the next day until you reach the current day The right W key brings you to the parameters of the last therapy session of the respective day until you reach the first ses sion of the respective day The right A key shows you the parameters of the next therapy session until you reach the last session of the respective day Resetting the memory Pressing and holding the E button for about b seconds will delete all saved data The display shows Clr for about 2 seconds and the device can be used for stimulation again The TENStem eco basic switches OFF automatically after two minutes if no key Is pressed Battery change If the battery voltage is less than 3 7 V the battery symbol appears in the display and it is necessary to insert in 4 new 1 5 V batteries AAA e g LRO3 To change batteries Switch OFF the device Open the battery compartment on
9. the back side of the device by sliding out the cover Remove the old batteries Insert the new batteries check polarity Close the battery compartment If you do not use the device for a longer period of time always remove the batteries In case you use rechargeable batteries please follow the instructions of the charging unit Please dispose old batteries properly 10 schwa medico TENStem eco basic Overview of key combinations Locking Unlocking a program Simultaneously press left W and P key for 3 seconds Changing stimulation time From series C Press E key Setting own programs From series C select P13 P15 press E key Entering date time mode From series C Press E key for 3 seconds Entering memory query mode From series C Simultaneously press left and E key for 3 seconds Switching ON OFF the sound From series D Simultaneously press E key and right for 3 seconds Press E to change between sound on off Pre set programs Program 1 Gate control 1 Both channels work with the same frequency and pulse width Frequency 100 Hz Pulse width 200 us Therapy time 30 min 10 to 90 min Indications Acute nerve or joint pain This program is used to treat acute neuropathic and joint pain The effect is Immediate Intensity Time 11 schwa medico TENStem eco basic Program 2 Gate control 2 Both channels work with the same frequency and pulse width see illustration Program 1
10. TENStem eco basic Transcutaneous nerve and muscle stimulator Art No 104041 Instruction Manual Art No 100863 V03 ll SDA schwa rmedicoOf MEDICAL EQUIPMENT schwa medico TENStem eco basic Contents General LEONI ONE ee es sehe 3 tended USD nee enge ee d EAEE 1 EA A er A E 3 Contra indication o oo ee cc ceccecccsescsesesesesesecavecsescecstscscsesesesesesesasacstscsessecssseeseteneeeen 4 ECT A 4 INDIE Sanne ence ete ee E E 4 VII erstere er 5 POSA T Ee ee 5 ss y 7 H 6 Description oo eccecceccccececscsesesesesessesesesassssesssessssssssasasassssesasassssesesasasieiesecseseeesasaees 7 Fy 0 EE E EAEE EEE A O E E PRE 7 Operating the TENStem eco base une i Seting daie and TIME TPTTTRRTRTTTETRTFTTRTTTTT 8 O CMON y O re rer 9 Resetting the memory eeenenneenenneeenennennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnn 9 ss MT YG INCI satanic atest ne re ea een 9 Overview of key combinations ennnnnnnnnn 10 Pre Es ONIONS een aE 10 User programs for OWN settings un 15 Electrode placements for pain programs enn 17 Electrode placement for dynamic stimulation eeeeeee 20 CVSS EIS Ol ee ae ee ee 21 Settings modifications and repairs eeeeeeeennennn 21 NE UMN EE EE E ANA 21 a 1a cls a E E ne 22 Maintenance and cleaning cccccecccsssscs
11. am 12 Deep TENS Program 12 works just like program 1 However instead of just one pulse four short pulses are generated Frequency 100 Hz Pulse width 75 us Modulation four pulses in a group duration of periods 275 us Therapy time 30 min 10 to 90 min This program could be called the last recourse If none of the other programs give analgesic effect However because of the high frequency this program Is often felt as less pleasant Furthermore high frequency stimulation needs more battery power Intensity Time User programs for own settings From series C Program 13 Gate control Both channels work with the same frequency and pulse width Frequency 1 120 Hz Pulse width 75 300 us Therapy time 10 90 min Intensity Time Program 14 Muscle stimulation The intensity continuously changes according to the indicated parameters Frequency 1 120 Hz Pulse width 75 300 us Rising ramp ZS Working phase DS Falling ramp 1s Pause 12s Therapy time 10 90 min schwa medico TENStem eco basic Intensity working time Time Program 15 Gate control dynamic The intensity continuously changes and the two channels operate alternately massage effect Frequency 1 120 Hz Pulse width 75 300 us Intensity modulation 1srise 1sfall Therapy time 10 90 min Intensity Time Program 16 lontophoresis Nerv block from series E Both ch
12. annels work with the same frequency and pulse width The current is monophasic We do not recommend to use P16 for more than 20 minutes Check the skin underneath the electrodes after the stimulation Frequency 1 120 Hz Pulse width 75 300 us Therapy time 20 min schwa medico TENStem eco basic Electrode placements for pain programs Back pain Epicondylitis ulnaris Epicondylitis radialis 18 schwa medico TENStem eco basic Arthrosis hip Kaada stimulation 1 channel only right handed left handed Sciatic pain Gonarthrosis knee pain Ankle joint pain 19 schwa medico TENStem eco basic Trigeminus neuralgia Migraine Polyarthritis 20 schwa medico TENStem eco basic Polyneuropathy Carpal tunnel syndrome Pain of achilles tendon heel pain Electrode placement for dynamic stimulation P10 P11 P15 The stimulation is not administered simultaneously on both channels The current flowes from one electrode to the other just like a wave undulating on the body This kind of stimulation is far more comfortable than traditional neuro muscular stimulation Dynamic stimulation can be used with high frequency parameters for a Improved pain control or with low frequency parameters for optimized muscle stimulation This treatment method also has an enhanced effect on lymphatic drainage stimulation The placement of electrodes for dynamic stimulation depends on the direction o
13. at an appropriate collection point and not place it in the normal domestic unsorted waste stream This will benefit the environment for all By labelling with CE certificate the manufacturer states that the product meets all active requirements of the regarding EU Directive A conformation evalua tion process has been successfully completed The code number of the confor mation evaluation process is given in accordance with the CE labelling of the involved notified body 2 channel nerve and muscle stimulator with electrically insulated channels 12 integrated constant current characteristic programs and from series C 3 user programs for own settings Power supply 6 0 V 4x 1 5 V battery AAA type micro e g LRO3 or 4 8 V 4 x 1 2 V rechargeable battery AAA Output current Max 100 mA therapy Approx 30 pA power down Dimensions Approx 140 mm x 64 mm x 28 mm Weight Approx 96 g without batteries Output current 0 60 MA with 1 kO load Pulse form Positive rectangle with negative component P1 P15 Positive rectangle without negative component P16 Frequency range Series A amp B 2 100 Hz from series C 1 120 Hz Pulse width series A amp B 75 250 us from series C 75 300 us Operating conditions Temperature range 10 C to 40 C Relative humidity 30 to 90 with 1kQ load P1 P16 Output Power Voltage Time Features schwa medico TENStem eco basic P1 P15
14. cscsessececsesesescecsesscecscsesssececscseseseces 22 B sg ON rennt omar dtr oat ease iin 22 Frequently asked questions oo eccccccscscsesecsesesesetecseseseseacscsesecsesssesesacseseseeaeeees 22 Eesti DE nee ee a ae 23 Prorom OVEN IEW AS ohoro hohoOoE zr 26 schwa medico TENStem eco basic General Information Intended use The TENStem eco basic has been designed for the generation of the transcutaneous electrical nerve and muscle stimulation and may not be used for any other purposes Safety instruction Please read the operating instructions carefully before using the TENStem eco basic The TENStem eco basic is only to be used for stimulation purposes on one patient at any one time Only use the TENStem eco basic with original accessories The size of the electrodes should to be not less than 2 cm The electrodes should be positioned in such ways that the current flow will not cross through the heart Keep the TENStem eco basic away from water or other liquids Do not drop the TENStem eco basic do not use it inappropriately or expose It to extreme temperatures or high levels of humidity not less than 10 C or more than 40 C or a relative humidity of more than 90 Do not use the TENStem eco basic if it is not working properly or if it has been damaged in any way Be careful when using the TENStem eco basic near or on children Keep the unit away from children Always store the TENStem
15. e electrodes have been positioned unfavorably Unpleasant side effects can be avoided by adjusting the intensity using another program with other parameters and the possible re positioning of the electrodes skin intolerance which can result from the electrodes the electrode gel or the electric current impulses The physician should be consulted in cases of reddening burning Itching or blistering under the electrodes or in the vicinity of the electrodes Slight skin reddening of short duration in the area of the electrodes following stimulation is quite normal because blood circu lation has been improved by the effects of the stimulation Muscular pain If the stimulation has been too intense or too long muscular aches in terms of sore muscle can occur Shorten the treatment time and the intensity of stimulation at the beginning of muscle stimulation to avoid muscle ache N Attention Read accompanying documents especially user manual BF type application part Protection against electric shocks pal The year of construction of the product follows this symbol The article or order number of the product follows this symbol ine gl C 0197 Technical data Pulse forms schwa medico TENStem eco basic The serial number of the product follows this symbol The letter indicated the series This equipment is marked with the recycling symbol It means that at the end of the life of the equipment you must dispose of It separately
16. f stimulation rising falling stimulation or sideways stimulation 21 TENStem eco basic schwa medico sideways stimulation Rising or falling stimulation for back or legs for gluteus or stomach muscle Ei Channel 1 a sasa NU 5 M Channel i Channel 2 Rising wave Falling wave channel 2 channel 1 channel 1 channel 2 Classification The TENStem eco basic is classified as being a Class lla medical device in accordance with the law for medical devices Settings modifications and repairs The manufacturer is only responsible for the safety and performance of the TENStem eco basic when settings modifications and repairs are carried out by authorised persons and when TENStem eco basic is used in accordance with the operating instructions Warranty Legal right of warranty is applied according to German Civil Code 22 Maintenance and cleaning schwa medico TENStem eco basic Guarantee The manufacturer issues a guarantee of 12 months from the date of purchase The guarantee does not apply in the following cases damage due to improper handling defects the customer is aware of on the date of purchase damage caused by the customer for wearing parts and consumable supplies like for instance electrodes batteries and cables No special cleaning or care agents are required for the TENStem eco basic Clean the unit with a soft fluff free cloth Please ensure that no moistu
17. hannel 1 100 Hz Channel 1 100 Channel 2 2 Hz Channel 2 2 First 10 min 100 Hz then 20 min with 2 Hz 100 2 150 200 10 20 3 s 100 Hz then 3 s 2 Hz etc 100 2 150 200 Automatic frequency run from 2 80 200 100 30 2 Hz to 80 Hz within 7 5 s Increase 2 s working time 5 s decrease 1 s pause 12 s automatic intensity adaption Intensity within 1 s to maximum then within 1 s reduced to 50 Both channels in alternating operation Intensity within 0 25 s to maximum 150 30 then within 0 25 s reduced to 50 Both channels in alternating operation Impuls packages of 4 impulses 100 75 30 200 us between each impuls Bothchamels 0 0 0 0 0 0 0 channels 1 120 75 300 ETE 90 Increase 2 s working time 5 s decrease 1 s 1 120 75 300 10 90 pause 12 s automatic intensity adaptation Intensity within 1 s to maximum then within 1 s 1 120 75 300 10 90 reduced to 50 Both channels in alternating operation Both channels with monophasic current 1 120 75 300 mm I L ELE i ll Tu schwa medico F MEDICAL EQUIPMENT schwa medico Export Department Wetzlarer Strasse 41 43 35630 Ehringshausen Germany Tel 49 6443 8333 113 Fax 49 6443 8333 119 Email export schwa medico de www schwa medico com Manufacturer Pierenkemper GmbH Hoernsheimer Eck 19 35578 Wetzlar Germany C Art Nr 451600 0265 0197 Stand 2010 11 03
18. hase 1 Phase 2 Frequency 100 Hz Frequency 2 Hz Pulse width 150 us Pulse width 200 us Duration 10 min Duration 20 min Indications Especially for lower back pain and sciatic pain syndrome Program 5 starts with high frequency stimulation for 10 minutes to give you immediate pain relief After 10 minutes it automatically changes to a 20 minutes low frequency stimulation with acupuncture type impulses to release endorphins and to retain the analgesic effect even beyond stimulation Frequency he 100 Phase 1 Phase 2 Time min 10 20 30 The duration of phase 1 and 2 is adjusted in the ratio 3 8 to 5 8 Program 6 HAN stimulation The device continuously changes between phase 1 and phase 2 Therapy time 30 min 10 to 90 min Phase 1 Phase 2 Frequency 100 Hz Frequency 2 Hz Pulse width 150 us Pulse width 200 us Duration 358 Duration 38 Indications All kinds of pain This program combines the analgesic effect of high frequency stimulation with endorphin release caused by low frequency stimulation Every 3 seconds It changes between a pins and needles stimulation and a pulsing stimulation Frequency Hz Phase 2 13 schwa medico TENStem eco basic Program 7 Burst This generates pulse packages Burst Frequency 100 Hz Pulse width 150 us Modulation Burst 0 5 s 0 25 s 0 25 s Therapy time 30 min 10 to 90 min Indications Diffuse nerve joint or muscle
19. ne electrode 38x45 mm 107010 silicone electrode 48x48 mm 107050 silicone electrode 70x65 mm 107070 silicone electrode 70x140 mm 108000 Contact gel for silicone electrodes 60 g N IN RY IN IN IN IN IN IN IN MedicoBack for the treatment of low back pain Low back support bandage with pelotte and integrated electrodes to be used with pain management programs of the TENStem eco basic MedicoBack P type offers patients lumbar vertebrae stabilization and support as well as easy stimulation provided by the integrated electrodes The pelotte with its massage nubs enhances the pain relieving effect MedicoBack P type may be used for slight or acute pain as well as for chronic pain in the lower back area Art No Article Size Length 107034 MedicoBack P type S 80 90 cm 107036 MedicoBack P type M 90 100 cm 107037 MedicoBack P type L 100 110 cm 107038 MedicoBack P type XL 110 120 cm 107039 MedicoBack P type XXL 120 130 cm Stimex garment electrodes gloves and socks The gloves and socks used in combination with the TENStem eco basic provide stimulation of the entire hand and or foot and ankle and avoid the sometimes tiresome attachment of self adhesive electrodes on the hand or the foot Gloves Art No Article Size Pair 107014 Stimulation gloves S 1 107021 stimulation gloves M 1 107022 Stimulation gloves L 1 25 schwa medico TENStem eco basic Socks Art
20. on function that prevents the increase of the intensity of improperly connected electrodes to the skin and also if electrodes are warn out of if cables are deffective have been using my TENStem eco basic for 2 months and I feel that the stimulation is less effective This could be due to the following reasons The electrodes need to be changed Your body has adapted to the repeated stimulation We recommend to change the program or the placement of the electrodes Can electrodes adhere to hairy skin In case of strong hair growth we recommend to shave the skin before placing the electrodes but usually this is not necessary Accessories The following accessories can be combined with the TENStem eco basic Stimex self adhesive electrodes Art No Article Pieces 281000 Stimex 32 mm round 4 282000 Stimex 50 mm round 4 283400 Stimex 50x50 mm 4 281032 Stimex 50x50 mm 20 283600 Stimex 50x90 mm 281007 Stimex 50x90 mm 283100 Stimex 80x130 mm 2 4 283000 Stimex 50x130 mm 2 2 4 281027 Stimex sensitive 50x50 mm 23 24 po vu LP gi e ko schwa medico TENStem eco basic Silicone electrodes to be used with contact gel Art No Article Pieces 107090 Silicone electrode 20 mm round 107060 Silicone electrode 25 mm round 107075 silicone electrode 40x28 mm 107035 silicone electrode 56x28 mm 107020 silicone electrode 75x30 mm 107055 silicone electrode 90x35 mm 107011 silico
21. ps automatically at the end of each program You can stop the stimulation manually at any time by pressing the P key or the e key Switching OFF the device Press the 9 key to switch OFF the device A single beep sounds The TENStem eco basic switches OFF automatically after 2 minutes if no key pressed Before you can use the memory query mode you need to set the date and time Pressing and holding the E key for about 3 seconds leads you to the date time mode In date time mode the LCD shows two figures The left figure indicates the date the right figure indicates the time Pressing the left A key increases the date by one day max 30 Pressing the left W key decreases the date by one day min 1 Pressing the right A key increases the time by one hour max 23 Pressing the right W key decreases the time by one hour min 0 Press the 9 key to save all parameters and to leave the date time mode again Date and time are continuously updated The TENStem eco basic switches OFF automatically after two minutes if no key is pressed In this case none of the adjusted parameters are saved schwa medico TENStem eco basic From series C First set the date and time see above The memory query mode is used to read out saved therapy data from patients By pressing and holding the left W and p n E key for about 3 seconds you enter the memory query mode If no values are Hr mv yy saved the display shows null for about 2
22. re permeates the unit If moisture does permeate the unit a technical check must be carried out before re use Delivery content Quantity Article Art No 1 TENStem eco basic 104041 1 Cable type 7 1 pair 104741 1 Stimex self adhesive electrodes 281015 50 x 50 mm 4 pieces 4 1 5 V battery LRO3micro AAA 604000 1 Operating Manual 100839 Frequently asked questions How many times a day can use the TENStem eco basic We recommend to use the device 3 times a day The pre set therapy time of 30 minutes per program should not be extended After a therapy session wait for several hours before using the unit again What intensity should I use Do not try to increase the intensity beyond the level which is comfortable You will either feel pins and needles or pulses depending on the program or frequency used You will notice that the intensity often feels different even if you stimulate the same area at different times of the day This is normal Do not hesitate to adjust the intensity to achieve a stronger but still pleasant stimulation STIMEX schwa medico TENStem eco basic The intensity of my TENS unit cannot be increased to exceed 6 8 mA Is my TENS unit deffective The TENStem eco basic is not deffective Check if the cables are connected correctly to the TENS and if the electrodes are connected correctly to the cables Iry to use new electrodes The device is equipped with a special electrodes recogniti
Download Pdf Manuals
Related Search
Related Contents
eyeWAVE™ Wireless PIR Camera Dual Levelar Owner`s Manual Intel 41210 Network Router User Manual - Techtop Canada ET1215L con pantalla LCD de 12 GML 10,8 V-LI Professional - Peterhans Fiche technique insecticide poudre pyrètre Tektronix 4686FP1 Printer User Manual BULLETIN D`ADHESION 2015 Guide to Purchasing High Modulus Synthetic Fibre Mooring Copyright © All rights reserved.