Home
The TP-83 programmable wireless indoor thermostat
Contents
1. AT This parameter allows you to enable or disable thermostat adaptive mode If enabled the thermostat switches on in advance according to the temperature persistence of the heating system Selecting this item and pressing and holding the knob for 5 seconds resets the thermostat 5 to the factory default settings By selecting OK and pressing the knob the menu is escaped from Miro 7 F mre m The parameter ranges are restricted according to the following table Parameter Adjustment Factory Description range default SPAN 0 1 C 0 2 C 0 5 C 0 2 C Hysteresis for switching tLo 6 C to 40 C 6 C Lower limit of t Hi 6 C to 40 C 40 C Upper limit of AL Lo 9 C to 20 C 3 Panic alarm AL Hi 30 C to 70 C 60 C Fire alarm Corr 1 C 0 Correction Auto On OFF On Adaptive mode o 6 C to 40 C 18 C Economical temperature x 6 C to 40 C 21 C Comfortable temperature tLo to tHi and to must be valid ranges t Lo must not be greater than t Hi and o must not be greater than amp TP 83 programmable wireless thermostat Party mode You can put the thermostat into party mode by briefly pressing the knob indicated by symbols amp and together After then the thermostat maintains the Comfortable temperature increased by 2 C Party mode terminates whenever a switch to Economy temperature regulation occurs whether manual or schedu
2. PAN parameter allows you to configure the hysteresis the accuracy to which the temperature is regulated One of the following accuracy ranges can be selected 0 1 C 0 2 C or 0 5 C the factory default setting is 0 2 C Example If the accuracy is adjusted to 0 5 C and the temperature is set to 24 C the thermostat switches the heating on when the temperature drops below 23 5 C and it switches it off if the temperature goes above 24 5 C In reality the temperature scatter can be slightly higher because of the temperature persistence of the room Warning too high an accuracy can cause the heating to turn on and off too frequently The t Lo parameter is the lower limit to which the economical temperature can be set In addition any drop in temperature under t Lo causes a heat to t Lo temperature signal to be transmitted The t Hi parameter is the upper limit to which the Comfortable temperature can be set ET m ore LI The AL Lo corresponds to the critically low temperature Any drop in temperature under AL Lo causes a Panic signal to be sent to the receiver reporting a frost threat AL Hi corresponds to the critically high temperature Any rise in temperature above AL Hi causes a Fire signal to be sent to the receiver The Corr parameter allows for a correction of possible temperature measurement offsets The range of adjustable corrections is 1 C WH Fe mo m 0 c ae rr 0
3. The TP 83 programmable wireless indoor thermostat The TP 83 is a wireless indoor thermostat with a programmable weekly heating schedule It is designed for indoor temperature regulation which balances economy with comfort The device is capable of recognizing warm up persistence characteristics within 2 days and will adjust the settings accordingly so that a high level of operational comfort is achieved You need not find out how early the heating should start in order to get to a comfortable temperature at the desired time The required timing is configured automatically Temperature adjustment can be performed by simply turning the setting knob When combined with an Oasis wireless security system Jablotron the following are possible e Switching the heating ON and OFF remotely by mobile phone remote control or Internet e Disabling the heating when windows are open e Informing the user about heating faults and frost threats if the temperature drops below a pre configured value a warning SMS is sent e Informing on the occurrence of fire when the temperature is above a pre configured value Button vA Tab Installation The TP 83 should be mounted in a dry indoor location Choose a mounting location about 1 5 meters above the floor in an area with good air circulation Avoid places with draughts dead air spots and radiant heat from the sun or appliances It should not be installed close to any metal structur
4. e desired value is displayed and confirming the setting by re pressing the knob this will also cause a return to the menu so that you can configure other parameters immediately The adjustment menu is escaped from by pressing the knob while OK is displayed or automatically after approx 30 seconds 1 M1 manual mode If set to manual mode the thermostat performs o fixed temperature regulation regardless of the b ge weekly schedule The desired temperature can be set within the range of t Lo to t Hi The M1 menu is escaped from by pressing and holding the knob for 2 seconds Note As mentioned above entering the M1 menu causes an enrollment signal to be sent 2 M2 temperature amp time setting If the M2 menu is entered turning the knob will scroll through the Economical temperature 9 Comfortable temperature and Time parameters followed by an OK option Each parameter can be entered by briefly pressing the knob When or X is entered the displayed temperature flashes and can be adjusted by turning the knob re pressing the knob confirms the setting The Time parameter adjustment is similar but requires three steps for the day hour and minutes 3 M3 programming the weekly heating schedule This mode allows you to program when the thermostat should switch between Day X and Night 9 operation The heating schedule can be programmed either for each day separately or just for working days or ju
5. e or other objects that may obstruct radio signal transmissions 1 Release the upper cover by pressing the plastic tab on the bottom side of the housing 2 Mount the back part on to the desired location 3 Insert the battery the polarity is marked on the holder 4 Close the thermostat Enrollment Install and connect the receiving unit to the heating system If the receiving unit was purchased separately then the thermostat must be enrolled to it enter enrollment mode on the receiving unit see its manual and either connect the battery to the thermostat or enter menu M1 both operations cause an enrollment signal to be sent Symbols on the display X Comfort temperature Economy temperature Programming Service menu Heating ON Low battery TP 83 programmable wireless thermostat Adjustment and programming All the required parameters can be configured in the adjustment menu using the knob The menu is divided into the following parts M1 manual temperature adjustment M2 setting the economical or comfortable temperature time adjustment M3 weekly programming schedule M4 service menu You can enter the menu and scroll through M1 to M4 by pressing and holding the knob The desired submenu is selected by releasing the knob Scrolling inside any particular menu M1 to M4 is done by turning the knob The currently displayed parameter can be adjusted by pressing the knob briefly turning the knob until th
6. led Displaying the set temperature When not being handled the thermostat shows the current temperature in the room If you want to display the temperature which is set for the current time turn the knob The set temperature will then flash on the display for 3 seconds Battery replacement Replace the battery when the low battery symbol is displayed or the thermostat stops working If the thermostat is enrolled to the control panel then a low battery will be indicated by the control panel to the user and installer Only use AA 1 5V alkaline batteries Integration into the OASIS system e The thermostat can be enrolled to a control panel as a detector If the temperature decreases below AL Lo a panic alarm will be triggered frost threat heating failure e If the temperature exceeds AL Hi then a fire alarm will be triggered e An AC 82 receiving unit has two output relays X and Y Thermostats can be enrolled separately to each relay in order to control two independent heating circuits e To operate a heating system the Oasis control panel can also be enrolled sequence 299 to the same relay of the receiving unit as the thermostat is enrolled to A thermostat enrolled to the X relay can be operated via the PGX programmable output and a thermostat enrolled to the Y relay operated via PGY If the programmable output of the control panel is switched on the thermostat maintains the programmed temperature If the control pa
7. nel s output is switched off the thermostat only triggers heating if the temperature drops below t Lo e To operate the heating RC 80 or RC 88 remote controls can also be enrolled to a receiving unit AC 82 The heating can be switched on by remote controls to heat to the desired temperature and also switched off where it only heats when the temperature is below t Lo e To disable heating when windows are open JA 80M or JA 82M detectors can also be enrolled to the same relay as the thermostat is enrolled to If the windows are closed it heats to the desired temperature and if windows are open it heats only when the temperature is below t Lo e Up to 8 thermostats can be enrolled to a single relay If at least one thermostat transmits a heat command then the relay will be switched on Specifications Power supply 1x AA 1 5 V alkaline battery Battery lifetime typically 1 year Temperature measurement 6 TC to 40 C Temperature accuracy adjustable 0 1 0 2 or 0 5 C Freeze alarm panic transmission temperature threshold lt AL Lo configurable from 9 to 20 Fire alarm temperature threshold gt AL Hi configurable from 30 to 70 C 868 MHz Oasis protocol up to 100 m open area 10 to 70 low humidity 66 x 90 x 22 mm Operational frequency Operational radio range Operational temperature range Dimensions Complies with ETSI EN 300220 EN50130 4 EN55022 and EN 60950 1 Can be operated accordi
8. ng to ERC REC 70 03 Jablotron Ltd hereby declares that the TP 83 is in compliance C Er the essential requirements and other relevant provisions of Directive 1999 5 EC The original of the conformity assessment can be found on the web site www jablotron com Technical Support section Note Dispose of batteries safely depending on battery type and local y Jablotron Ltd Pod Skalkou 33 regulations Although this product gt 466 01 Jablonec nad Nisou EE does not contain any harmful Czech Republic materials we suggest you return the Tel 420 483 559 911 product to the dealer or directly to fax 420 483 559 993 the manufacturer after use JABLOTRON Internet www jablotron com MKL51904
9. st for the weekend or for all days together Sa Sul Mo Tu We Th Fr Sa Su PRG PRG PRG PRG Enter the M3 menu scroll to the desired option by turning the knob and enter the schedule programming by briefly pressing the knob this erases the current schedule setting Schedule programming is done by marking periods of time for which the Day heating operation is requested The marking bar is shown at the bottom of the display each hour can be either marked or unmarked You mark or unmark by turning the knob The mark unmark mode is displayed by 3 9 symbols the currently programmed hour is shown on the display 00 to 23 Switching between mark unmark modes is done by pressing the knob this applies when turning clockwise turning the knob anti clockwise always switches to unmark mode Turning the knob to the rightmost position following hour 23 will display an OK option Pressing the knob will then finish programming MKL51904 a M4 Service menu This menu allows for the configuration of parameters which usually stay fixed during normal operation When the service menu is entered the Om symbol is shown on the display The menu contains 9 items they can be scrolled through by turning the knob Each of the first 7 items corresponds to a parameter which can be configured in a standard way by pressing the knob turning the knob until the desired value is displayed and re pressing the knob SP An The S
Download Pdf Manuals
Related Search
Related Contents
Guía de administración del servidor Sun Fire T2000 Fluidmaster 7500P5 Installation Guide Acer Projektor P5227/P5327W/P1285i/P1285B - HiFi TAXI_3 MALLES AVANT.indd - Hachette C:/Muriel/breves/Br\350ves mardi/Br\350ves 426.sla MODEL 4100 AC Rev D. USER`S MANUAL PRV DDE I/O Server Manutention aérienne Copyright © All rights reserved.