1. enter time max 4h33m03s Defer auto arm XXX K for h m s Figure 11 ARMING MODE This function provides for selection of a special mode of arming There are three options of arming modes Full Stay Stay delay O off Details concerning the use of functions are discussed on page 16 of this Manual Section System Arming Upon selection of the arming mode the control panel returns to the user function menu thus enabling the selected partitions to be armed Exiting the menu without arming key will cancel the selection made by using this function select and press code Arming mode gt gt Arming mode T Full Figure 12 CHANGE OWN CODE This function makes possible to change the code of the user who called this function To increase the safety of the system it is recommended to change user code periodically The control panel requires code change from a newly entered user who has the right to change it because his her code is known to the person who entered the new user to the system Each time the new user enters his her code the message Change code appears on the display This message appears until the code is changed to another one Access to rights and partitions assigned is not blocked when the code remains unchanged The requirement of code change may be arisen by guessing this code by another user The situation
2. When the arming function access code or quick arming O is called the following message appears on the LCD display Vibration sensors test xx s 1 arm where the xx field indicates the number of seconds before the end of test During the test the control panel is waiting for the violation of vibration zones in a given partition If all the vibration zones of the given zone are violated the alarm control panel switches over to counting the exit delay time and arming the system In case some of the vibration zones are not violated during this time the control panel will display a list of faulty zones number and name of zone and will not arm the system Operation of control panel CA 64 17 Pressing the digit 1 key during the process of countdown will interrupt the test and arm the system in normal mode while pressing the key will make it possible to cancel the arming Arming the system from the partition keypad will bypass the testing of vibration sensors in the particular partition Also special control ways of partition status are possible e partition arming and disarming by means of timers Timer is an internal control panel logic unit which measures time Timer operation is programmed by the service e partition arming and disarming by means of a partition user timer This timer may be programmed by the user without necessity of asking the installer or the service for that There is a single timer of this
3. Masters LS xxx E service Users xX graph Zone bypasses Set time XXX Failures oo Reset zones a Change options Bl xxx master Take SM service mode over Downloading o 8 Table 1 BLOCK DIAGRAMS AND DESCRIPTION OF USER FUNCTIONS User functions are shown in block diagrams The texts which appear on the LCD keypad display or name of list accessible in the form of menu for scrolling are shown in frames The list is scrolled by means of keys ff and 4 The function which may be selected is marked with arrow at the left hand side of the function name on the keypad display gt Function name Press key or gt to move to the next block in the diagram function execution stage according to direction shown with arrows The return from some menu levels to previous menu level is possible by pressing the key marked Pressing the key at each menu level means mostly abandoning execution of the function selected and return to the main menu The user must be authorised to use the function to make it displayed by the control panel Execution of each function is confirmed with proper message which is shown with a symbol at the block diagrams describing functions end of function execution the control panel displays a proper voice message and returns to the basic status 22 Usre s Manual CA 64 SATEL DATA ENTERING Some functions require typing of a new code or a user name The way of entering new data th
4. Erase DALLAS Save y press K Read card for Read card for Card read the first time the scond time Figure 15 Note The way of reading in and removal of DALLAS chip are identical with proximity card reading in and removal see Notes in description of function USERS USERS The function that gives the right to enter new alarm system users Define the user authorisation and type when entering him to the system The type is an additional code property to be assigned to an ordinary user of the alarm system If proximity card readers are installed in the system read in the card which will be used by the new user Description of user functions 29 Authorisation rights list to be assigned to the new user is as follows it indicates the functions which the user will be allowed to execute Arming Failures viewing Disarming Events viewing Alarm clearing Zones resettings Object alarm clearing Options changing Other alarm clearing Tests Arm deferring Downloading Code changing Disarming after Users editing Voice messaging clear Zones bypassing Guard64 using Clock setting Access to blocked partitions Note The right Switch off for somebody else defines whether the user always may disarm marked option or only when he previously armed by himself marking cancelled The list of user code types is as follows 1 2 3 Normal basic code type assigned to th
5. s Manual EXPLANATION OF SOME TECHNICAL TERMS All definitions are valid for the alarm system based on control panel CA 64 STARTER FLASH memory 2402 memory DLOAD64 GUARD64 subsystem partition zone zone violation output relay output bus expander The program activated in the control panel after power supply switching on the purpose of which is to check correctness of the basic program stored in FLASH memory and make possible to load a new control panel software version into this memory The memory where the control panel basic program is stored It is cleared electrically and its contents may be changed with the use of computer Additional non volatile memory where important system parameters are stored for example administrator codes etc Computer program that enables programming of control panel settings with the use of computer so called service program Computer program that enables operation of the alarm system with the use of computer so called user program The group of partitions being an independent alarm system Eight groups of this type may be created on the basis of control panel CA 64 The group of zones supervising separated part of object arming and disarming is carried out simultaneously for the group The alarm control panel CA 64 allows creating of 32 independent partitions Pair of contacts at the control panel main board or module board connected to the control panel
6. the installer may program audible signalling in an LCD keypad for the following situations Alarm for a partition continuous sound for the total alarm duration time programmed by service Fire alarm series of long sounds every second for the total alarm duration Count down of time for entering short sounds every 3 seconds Count down of time for exit long sounds every 3 seconds completed with a series of short signals for 10 seconds and a single long sound The way of signalling of time for exit informs that the count down is finishing Signaling the auto arming delay time countdown timer controlled partitions a series of 7 sounds of diminishing length Gong in the LCD keypad five short sounds this is a response to activation of some detectors when the zone is disarmed THE USE OF LCD KEYPAD Operation of the system from LCD keypad starts with entering the user CODE and pressing the key marked or Note that the control panel response functions accessible after pressing the key is different from that generated after pressing the one The specific feature of the control is the dynamic changing of the accessible menu dependant on the system programmed parameters as well as on the authorisation level of the user who entered the code The designers of the control 8 User s Manual CA 64 SATEL panel have chosen such a way of its control to facilitate operation by users who do
7. APPENDIX D examples of keypad operation sessessesseseosoesessossesoessesoosoesessossesoessesoesoesessossessossesoesseseesseseseo 43 APPENDIX E functions of keys and lamps ccoccooncooncnnncnnccnnononononononnononocono conc cnc non oooncoonconocononccono coronan cono cns 50 Operation of control panel CA 64 3 INTRODUCTION The control panel CA 64 is intended for controlling operation of alarm systems which monitor and supervise the security of medium sized and large objects Supervision is not limited to protection against burglary but may also include monitoring the correct functioning of the object for 24 hours per day The status of the alarm system is monitored continuously Violation of any alarm system component results in a so called tampering alarm The control panel responds to signals from individual detectors and decides whether to activate alarm or not Since various detectors may be connected to the control panel type and way of alarming depends on the control panel software installed the control panel may respond in a different way to a signal from fire detector than to a signal from a water level detector The control panel allows grouping of detectors zones to obtain so called partitions as well as free choice in determination which partition is to be monitored armed Activation of any detector from such a group called zone violation in the below text may trigger an alarm High flexibility of the co
8. by means of bus to which the detectors are connected The control panel monitors detector statuses via the zone Monitoring of 64 zones is possible Change of zones status when the detector is activated for example zone contact opening or shortening change of detector parametric resistance Pair of contacts at the control panel main board or expander module boards where the voltage is controlled by the control panel It is possible to control 64 outputs including relay outputs Electromagnetic switch located at the expander board controlled switched over by the control panel The group of wires to which the modules operating with control panel main board are connected The control panel CA 64 is provided with three buses One bus is used for connecting LCD keypads and two buses for connecting expanders Electronic device which extends control panel features There are expanders to increase number of control panel zones or and outputs Also partition keypads coded locks and proximity card readers are included It is possible to connect up to 64 expanders to the control panel CA 64 SATEL Appendices 43 APPENDIX D This appendix contains descriptions of examples of activities to be carried out when calling some user functions The first column indicates which keys must be pressed the second column contains description of operation called and the third one shows texts displayed on the LCD keypad after the oper
9. that the user code is guessed may occur when entering a new user or during normal code change procedure by any system user The guessed code is rejected when changing the code and the owner of this code is asked to change it see Notes page 22 Also the control panel suggests to change the code for the users assigned with the type Temporary renewable The function does not accept a code already existing in the system Description of user functions 27 It is possible for the service to activate the option of blocking creation of codes easy to guess When this option is activated the control panel does not allow to create codes of type 1111 1234 1122 etc These codes are rejected and the control panel waits for another combination of digits Notes The control panel does not accept the code identical to the old code as a new one Change of a guessed code requires more complicated procedure code change with confirmation Figure 13 The administrator may confirm user code change with his administrator code and the administrator code must be confirmed by the service personnel with the service code The use of the service code is possible after unblocking the service access by the administrator Basic procedure type new CODE code Change ovn code New code xxx K Figure 13 Change procedure for a code guessed message press type new code code gt Code r
10. the arrow key f each single pressing deletes a character at the left side of the cursor Press arrow key YU to enter space at the left side of the cursor use arrow keys and to move the cursor under the user name backlighting the position to be changed To change the character at the position indicated by the cursor repeat pressing the key with the proper digit so many times until the proper character appears Then move cursor to the next position and repeat the procedure Pressing accepts data entered Pes Hi 8 l1 e 4 1 AlalAla Bb Clc Clel2 CAE G gl Hlhi li 4 Jij KI kIiLit lel 5 Mi m N n R O 0o 6 6 Pps Qe qe Re Ss Ss 17 Tit U u Viv 8 W w X x Y y Z z Z 9 4 deze E ee gt D EE 8 Table 2 Characters accessible for the text mode of data entering Description of user functions 23 DISARMING The function allows disarming in a single partition several partitions selected or all partitions accessible to the user from a specific keypad select code Disarm all mark selected K Disarm selected What to disarm d Partition name graph code xP Disarm Figure 3 CLEAR ALARM The function clears alarm signalling and clears memory of alarms occurred since the last alarm memory clearing Alarm memory clearing does not include th
11. 1 to 4 event type numbers according to the list given below List of event types 1 Zone amp tamp al Alarms for zones tamper alarms 2 Other alarms Other alarms Fire auxiliary technical alarms no sentry round 3 Arm Disarm Clr Arming and disarming alarm clearing 4 Zone bypasses The use of function zones bypass bypass cancelling after disarming 5 Access control Use of keypads and proximity card readers for controlling electromagnetic door locks door status monitoring temporary bypass of partitions 6 Failures Failures Technical problems in the system restarts of modules 7 Functions Functions Calls for user functions to control the operation of the control panel 8 System System events Service mode clock programming etc Note The messages about the following event types are not displayed in the event lists on th LCD keypad Attack alarm PANIC Silent attack alarm silent PANIC Forced activity alarm DURESS type code No additional message is displayed when exiting the function Description of user functions 35 code mark types Event classes oul select in sequence Event type name Select events mark partition Events Select part 4 gt Part events to select View Zone name graph Selected press to exit All DD MM HH mm IDEN Event name Figure 20 Note The lis
12. 12345 6 7 8 9 0 I 2B 4 5 Dasa tam all Disarm selected 17 1819 02122324 5627 28 2 30 31 CONTROL PANEL 132 0 When you press key or all partitions armed and accessible for the user will be disarmed If only one partition is armed it will be disarmed just after pressing key together with displaying the end message If an alarm is signalled for the partition it may be cleared together with disarming Indication of the function Disarm selected Calling of the function 12 3 4 5 6 7 8 9 0 I 2B 4 5 What to disarm Workreom 1 Scroll the list with partition names Press one of these keys so many times as you need to display the name of the partition required partition 2 Book keeping SERWCE O 17 1819021234 5627 282930 31 CONTROL PANEL 1 32 Q ZONES 1 69 After the function is called the control panel displays partition names factory set or entered by the installer which the user may disarm Press key to move to the graphical mode of partition selection selection in the graphical mode is carried out in a way identical with arming 12 3 4 5 6 78 9 0 I 2B 4 5 Mark the partition selected for disarming fj mark at the right hand side of display using any a What to disarm numeric key Book keeping SERWCE 17 1819 2222324 52 27 28 9 39 31 CONTROL PANEL 1 32 Q ZONES 14 You may select fo
13. 19 DARBA 2 2 27 22 2 30 31 CONTROL PANEL CA 1 2 3 4 5 6 789 01 2 B 4 B Zone bypass 01 DUAL cont toem ISERMCE O 17 18 19 02122324 5627 823 30 31 CONTROL PANEL 1 32 0 CA 64 zones Zone bypass 04 Entrance door 123456 789 01 2 B 4 B Zone bypass 49 0 PIR secre Oia ce 17 1819 02122324 25 2 27 28 2 30 31 CONTROL PANEL Appendices NOTE Example 4 49 End of selection and bypassing of status Pon pe A ee ee za ia monitoring for all zones detectors marked Zone bypassed Saver serwce O 17 18 19 02122324 25 2 27 28 2 30 31 CONTROL PANEL 1 32 Zone bypass is cancelled after disarming of the partition to which the bypassed Zones belong ZONE STATUS VIEWING function called by long keeping pressed of the key 12 3 4 5 6 778 9 01 2 B 4 SE Call the function of control panel zone status viewing Keep pressed the key for approximately 3 seconds information on first 32 system zones will be shown in the graphical mode display 17 1819 2212 23 24 2 2 27 28 22 30 31 CONTROL PANEL 1 32 CA 64 zones 164 365 0 The LED 1 32 being ON indicates the set of zones the status of which is shown on the display Symbols representing zone status are described in the User Manual CA 64 description of function Tests Move to the second ZONE set display ZONES AAA a 33 64 Use any arrow key to do that Yo
14. 20 BLOCK DIAGRAMS AND DESCRIPTION OF USER FUNCTIONS eee see enae eee nasa a nana azaacaacwae 21 DISARMING 4a asza Matai e GZ RA RO W Sa A 23 CLEARATARM ad RAR OOOO LO WAR ZNA WO AO SRB AA BARA 23 CLEAR OTHER ALARMS z O WA A GOA dE R AO id 23 PV X0 SAO 0 91 PRKYECEJ LEZ 23 ARM Ryk NA ot OOO TAk o A O o Z ISA ZE Mn tak ote cer a lO 24 ARM 2 CODES a aid ii a AO ieioea aar eds Ena ea ON a i o reris 24 DISARM 2 CODES iii T E E 24 DEFER AUTO ARM viciosa indiana eS NERSE E ESEK P a da Taek es C Tas Eskri REES 24 SET AUTO ARM DELAY 4 3 sciccccscedcievessncesvuseccesatscciveedcedeusstcacsecchdesshccteedubectsadaiastssdetceddhcctsedvisetsedseceuesuseeseucs 25 ARMING MODE sviesesne dekio anr eaa ie aer iKa a AA d Eeer dak Eer eak ra Seip a eaei ak 26 CHANGE OWN CODE sd e oertain Wda arasa a ni aa r eaid aard ZAC 26 MASTERS l 27 USERS lt a 28 ZONE BY PASSES vio ias 32 SET FIME OO 32 FAILURES icon EE RRC 33 EVENTS aoc sh Scent oe Soe A ANIE dh ives a E OK A Steere Skeets 33 RESET ZONES ua ita 35 CHANGEZOPTIONS 0 tite O ROG OWO ARGE ada 35 TESTS zzo RE AO A RAZEM AO RAA R ROCK WOW O A M eo AG SEN 36 SERVICEACCESS A acim tie Oo old eR eas tec ahs aCe eo A AEO DO at es Shed vine es OE 39 SERVICE MODE ib 39 SM TAKEO VIER iii e bs ate 40 DOWNLEOADING sos E Oi ehh al de 40 SUMMARY AAPP O 41 APPENDIX C explanation of some technical terms ssccscssscssscsssssscssscssscsecssessecssecssssscssssssssssssssesens 42
15. CONTROL PANEL CA 64 software version 1 03 xx User s manual Przedsi biorstwo Produkcyjno Us ugowe Saded GDA SK ca64u_e 06 01 USER S MANUAL Przedsi biorstwo Produkcyjno Us ugowe CONTROL PANEL Bare June a 2001 POLAND Thank you for choosing the product offered by us High quality large number of functions and simple operation are main advantages of the control panel offered by SATEL s c Hoping that you will be fully satisfied with this choice we declare to provide you with professional assistance and information on our products We would like to inform that besides control panels SATEL s c produces many other components of alarm system Look for detailed information on our full offer in retail outlets dealing with our products at our website www satel pl or directly at out site tel 58 32 09 410 fax 58 32 09 401 We kindly ask you to read the entire Manual carefully since detailed knowledge on the control panel functions will allow you to fully utilise all included possibilities This Manual is very general and deals with the basic operation of a typical alarm system installation The control panel may carry out functions that are nor related directly to monitoring We are not able to foresee all possible ways of use of all the control panel functions available The use of all control panel functions and efficiency of operation of the entire system depend on the installation itself and the software in
16. HH MM everyday weekly Save Tue HH MM HH MM Wed HH MM HH MM Thu HH MM HH MM Fri HH MM HH MM Sat HH MM HH MM Sun HH MM HH MM Save Figure 22 ULE The function allows performing various operations for checking the system operation correctness Arming status Checking the current status of partitions accessible for an individual user and operated from the LCD keypad The partition status is shown in the form of symbol mark adjacent to the number numbers around the display screen which corresponds to the partition number in the system The installer assignes symbols marks to particular situations It is possible to read the following information on zones Description of user functions 37 b temporary partition bypass entry delay w exit delay less than 10 seconds W exit delay more than 10 seconds Cc zone is armed zone is disarmed Zone status checking the current status of each zone in partitions accessible for an individual user Zone status is shown in the form of a symbol mark adjacent to the number numbers around the display screen which corresponds to the zone number in the system The installer assignes symbols marks to particular situations Two sets of information on zones are displayed first set for zones 1 32 and second one for zones 33 64 Two green LEDs next to the display indicate which set is displayed curr
17. L PANEL 12 07 CA 64 zones 161 48 User s Manual Example 3 ZONE BYPASSING Bypass zone No 4 named Entrance door and zone No 49 named PIR secr office the user code 38407 38407 Type code calling the user function menu or Hor or or 12 3 4 5 6 78 9 0 L RBH 5 Lu PATM r Change own code 17 1819 02122324 52 2 28 2 39 31 CA 64 SATEL CONTROL PANEL 1 32 0 CA ZONES The use of most user functions except functions called with longer pressing of a single key and the function of quick arming starts with entering code and pressing key or example 1 and 2 Scroll the list with accessible function names Press one of these keys so many times as you to display the name of proper user function next to the arrow Select function indicated with arrow moving to the stage of zone detector selection to be bypassed Scroll the list with zone names Press one of these keys so many times as you need to display the name of the first zone to be bypassed Entrance door next to the arrow Mark the zone selected for bypassing IJ mark at the right hand side of display using any numeric key Scroll the list with zone names to select next zone detector for bypassing PIR secretary office Marking of the Zone selected for bypassing 123456 789 01 2 B 4 5 Change own code gt Zone bypasses 17 18
18. asters graph master Panel version Figure 23 SERVICE ACCESS The function allows the installer to access the system by means of the service code It is accessible in the administrator menu only It requires data entering number of hours when the alarm system will be at installers Service disposal The access to the system is blocked after this time elapses Typing zero with this function in place of number of hours when service access is opened automatically blocks the access Access time is counted down whether the service mode is started or not Access time counting down may be interrupted by power supply disconnection mains 220V and battery only With this function you can check how much time is left from the access time limit given by the administrator indication 00 means that the last hour is being counted down type number of hours 1 99 code k gt Service access b Service access XXX TPR K time h Figure 24 SERVICE MODE The function starts a special control panel operation mode The list of the Service functions is accessible in the separate instruction manual for the installer The control panel does not signal alarms from most of zones including tamper alarms it responds to violation of some zones armed for 24 hours and alarms from partition keypads and coded locks functions of long time key pressing In this operati
19. at relate to system users is described below When changing the code the control panel does not show the old code unless the user has not changed the code assigned for him by the person introducing him to the system yet But the old name always is shown on the display when changing the old name The user name entered appears in selection lists printouts and when viewing the event memory in the computer e new code time limit numeric data are entered by means of numeric keys Arrow keys are used for modification of numbers being entered Below the text field where digits entered appear the cursor dash is seen Arrows and gt are used for moving the cursor to show digits in sequence Press the key with digit to enter the digit required at the left side of cursor and press the arrow ft to delete the digit at the left side of cursor The arrow U change cursor type blinking dark rectangle appears Cursor of this type allows changing the digit above the dash to the digit typed at the keyboard Press key again to return to the previous cursor type e user name user name is entered by means of numeric keys which change their meaning and allow entering text data letters to the control panel Table 2 contains characters accessible at the keypad keyboard Subsequent pressing of the key with a digit changes the characters in a cyclic way The new user is entered by changing the factory entered name You may delete the old name by pressing
20. ation is executed and the comment on the situation obtained Since the user function menu depends on software installed by the installer and specific user authorisation texts shown here are for orientation only and may be slightly different in practice Example 1 1111 NOTE ARMING part I partition No 2 named Book keeping belonging to the subsystem 1 user the subsystem master 12 3 4 5 6 78 9 01 2 B 4 5 Enter a user code the factory set master code Code recogni zed for the subsystem 1 Sarel change it Also you can enter the code of any user who sag x i 17 1819 02122324 2 2 27 28 22 30 31 has access to the partition 2 and authorisation oa for arming cet This message is displayed when the user has the right to change the code and should make this change see User Manual CA 64 description of function Code change 12 3 4 5 6 78 9 0 1 1 2B 4 5 Confirm the message SArm all i Arm selected 17 1819 2122324 52 2 28 2 30 31 CONTROL PANEL 12 07 64 zones a If you press key or all partitions accessible for the user will be armed If some of partitions accessible for the user are already armed the control panel will make available the functions of disarming only but if just one partition is armed it will be disarmed To arm the remaining partitions first call the user function menu by typing CODE see continuation of the example ARMING
21. der of zones or partitions in the system The information on alarm activation is stored in so called temporary alarm memory until the contents of this memory is cleared by an authorised user see Description of User Functions gt Alarm clearing The contents of this memory may be checked many times after resetting the alarms until it is deleted 10 User s Manual CA 64 SATEL PARTITION KEYPAD ALARM ARMED FAILURE Figure 2 Partition keypad is provided with 12 keys with permanent or temporary backlighting service setting and three LEDs described as follows e ALARM red steady light indicates an alarm in the partition operated with this partition keypad and blinking indicates that alarm occurred in this partition earlier e ARMED green steady light informs that the partition assigned to this keypad has been armed The LED blinks when the time for exit is being counted down e FAILURE yellow the LED blinks when a technical problem has been detected in the system Check the LCD keypad for the type of failure Indication of this LED relates to the entire system not only to the partition operated with this keypad Arming of a partition switches off the LED and disarming causes the LED to lit again When all of three LEDs ALARM ARMED FAILURE flash in sequence this indicates missing communication between the keypad and the control panel This situation may occur when program STARTER runs in th
22. e max 4h33m03s E Defer auto arm xxx k for h m s Figure 10 SET AUTO ARM DELAY The function puts off delays the arming of a timer controlled partition auto arming It is intended for programming the value of time interval by which the moment of automatic arming of a partition is to be delayed The maximum postponement time value is 4 hours 33 minutes and 3 seconds Entering a higher value will set the maximum permissible value while entering the zeros alone will restore the partition control according to the installer s settings Operation of this function pertains both to the Partition user timer and the Timers programmed by the installer The postponement time is programmed individually for each automatically controlled partition The function is available in the user menu if the user is authorized to get access to at least one partition for which a non zero auto arming delay time has been set service setting The value of such a delay may vary from 1 to 255 seconds Activation of the timer controlling the particular partition triggers the process of counting the auto arming delay time Then countdown of the partition exit time takes place if provided followed by arming the partition 26 Usre s Manual CA 64 SATEL select partition code x Set auto arm d gt Paritonamen t nm numbers of auto Partiti matically controlled artitio name m partitions
23. e code select in sequence Telephone code XXX Code mark selected Telephone code User partitions select Partitions gt Partition name graph User type 8 Type iQ Ha Type name Rights type name Name gt User name g mark selected Existence time User name Rights 2 Bypass time type number of days 2 255 Right name Read prox card Code existence me Erase prox card time d Read DALLAS press digit 1 Erase DALLAS type time in minutes 1 109 Erase card 1 Yes Part blocking time m XXX Read card for the first time Figure 16 Read card for the second time press Card read 32 Usre s Manual CA 64 SATEL Notes Telephone code is to be typed in this case only when the user wants to use the control panel function Answering phone calls see Operation of control panel CA 64 The card may be read again after minimum 2 seconds from the moment of card removal from the reader Actual removal of a card from the control panel memory takes place at the moment of exiting edition or accepting the user function with the function Save The way of reading in and removal of DALLAS chip are identical to proximity card reading in and removal ZONE BYPASSES This function bypasses zones from the moment of the function entry The control panel ignores all information coming from detectors connected t
24. e code by a user who accidentally guessed the code NOTE With a big number of users it is advisable to use longer codes at least 5 digit ones to reduce the chance of guessing the code of another user CODE LOCK The coded lock looks similarly to the partition keypad The code lock is provided with 12 key backlit keypad Keypad backlit may be permanent or temporary service setting The lock is provided with three LEDs marked as follows e STAND BY green LED is on when the lock is operated by the control panel and the door may be open e ACCESS red LED is on when the door lock is being unlocked e DOOR yellow this LED shows the status of zone which monitors the door status The LED is ON when the door is open When all three LEDs STAND BY ACCESS DOOR flash alternately that means there is no communication between the code lock and the control panel This situation may occur when program STARTER is running in the control panel or the cable connecting the code lock keypad to the control panel is damaged Operation of control panel CA 64 13 The basic code lock function is to control the access to the room where the door provided with electric catch bolt or electromagnetic interlock are installed Also the lock may be used for partition checking when sentry round in the object To open the door type CODE at the lock keypad and press key or x The user must have access to use this code lock gt CODE d
25. e control panel or the cable connecting the partition keypad to the control panel is damaged There is a possibility to program a partition to be armed or disarmed after entering two codes service setting In this event after entering the first code LEDs ARMED and FAILURE start to blink and the control panel waits for entering the second code Similarly to the LCD keypad the partition keypad may generate audible signals This way the control panel confirms the function called since there is no display at the partition keypad One long beep refusal of arming the zone which shouldn t be violated at the time of arming is violated option PRIORITY Two long beeps the code is not known to the control panel Two short beeps acceptance of the first of two codes needed to arm or disarm Three long beeps the code cannot control this partition Three short beeps confirmation of partition arming and disarming Three pairs of short beeps it is necessary to change the code for example a user when changing his code has entered an identical combination of digits as in the code of another user or end of code validity is approaching Operation of control panel CA 64 11 Four short beeps and one long beep the confirmation of the performance of acontrol function code change and of a guard round Five short beeps the dependent door are open the door control has not been performed To operate the
26. e event memory where the facts of alarm occurrence and cancelling are registered and kept fully described The function is executed automatically when the system is armed and alarm occurs after the code is entered and key is pressed Then the control panel displays the menu of the function Disarm and after this function is executed it displays an adequate message code Clear alarm gt K Figure 4 CLEAR OTHER ALARMS The function allows cancelling alarms from other subsystems to which normally the user has no access code x x Clear other al r K Figure 5 ABORT VOICE MESSAGING When this function is called messaging by telephone is stopped the control panel should ring off If the telephone line is still occupied that means that messaging for the partition non accessible for a given user is carried out Messaging by telephone may be cancelled automatically together with an alarm clearing service setting Note If the installer has not specified the partition for a selected telephone number the users of which can cancel messaging by telephone the procedure of messaging by telephone to this phone number will be carried out till the end without possibility of stopping it code Abort voice m gt K Figure 6 24 Usre s Manual CA 64 SATEL The function allows arming of a single partition few partitions selected or all partitions accessible to
27. e for the user is already armed he she may arm other partitions when he she types at the keypad gt CODE arming by selecting arm from the function menu see Description of User functions There are some special methods of system arming possible in a partition available from the LCD keypad activate without internal zones the control panel does not respond to violation of zones defined as internal by the installer This possibility allows user to stay in the object and arm The object is protected externally in normal way and the system performs all functions programmed arm without delayed zones arming is performed in a way similar to the previous case but additionally the delayed zones act as immediate ones To arm the system in one of the presented modes proceed as follows 1 Enter ACCESS CODE and press the key 2 Call the Arming mode function 3 Using the and Y keys select one of the suggested arming modes and press 4 Call the Arm function and select highlight the partition to be armed 5 Press the key Disarming the partition will cancel the special mode of its arming To re arm the partition in a special mode the procedure described above must be repeated The procedure of arming the system from a LCD keypad in the partition where the type 10 24h vibration zone belongs and the testing function of vibration sensors is activated service setting is slightly different
28. e fu Figure 22 2 Then select operation mode daily or weekly 3 Programming of timer on and or off time is the next step To do this select the function for daily mode timer gt Cod HH MM HH MM and press key or the message Timer switched on every day HH MM on the display 4 Then enter hour HH and minutes MM of timer switching on Press key f or U to enter hour and minutes of timer switching off To accept data entered press key 36 Usre s Manual CA 64 SATEL The display will show the name of the timer set data programmed For a weekly cycle timer the time of switching on and or off is programmed in the same way but it should be done for each weekday separately When you enter only nines the function will not be active For example the timer may arm only at the determined time but disarming must be performed by the user himself automatic partition control may be activated in some weekdays only In order to save timer settings in the control panel memory exit option programming with the function SAVE code Change options Keypad chime mark selected t K Outputs chime gt Outs chime bl oul Part timers Code name graph in Partition name f A Z gt Active lt lt Part timer active A AR NEK everyday weekly press or U to change ii Timer type Evd HH MM HH MM Mon HH MM
29. e user Single use code for use once only Temporary renewable code for which the validity time period is given when entering a new user Before the validity period elapses the control panel reminds the user with such a code that he must change the code After this change the validity period is counted down from the beginning After this user code type is chosen when entering or editing the function Validity period appears in menu see Figure 16 where number of code validity days should be defined Temporary non renewable code for which the validity time period is limited to the number of days specified when entering a new user After this user code type is chosen when entering or editing function Validity period appears in the menu see Figure 16 where the number of code validity days should be defined Validity period may be changed for this code type by the user who entered a new user or by the administrator or the service Duress code similar to the normal user type but the use of this code generates additional event which is sent to the monitoring station Alarm forced activity At the same time this code may activate a special alarm adequate for the situation programmed by the installer This code is intended for use in the case of attack Monostable output code which switches on the MONO switch type outputs This function may be executed in partitions assigned to a code o
30. ecognized Change ovn code F gt New code XXX change it Type confirming code press digit 1 Enter xxx gt Change 1 Yes gt K confirming code User name Figure 14 MASTERS This function is used for entering the new user with administrator authorisation changing data related to the existing administrator or for removing the administrator Only the installer service is authorised to use this function Only one user with such authorisation may be assigned to the subsystem The list of rights which may be assigned to the administrator is identical with the list shown in the description of the function Users The changes made become valid in the system since the moment of exiting the function using the command Save 28 Usre s Manual CA 64 SATEL Code x select according to subsystem no n Masters New master n T Edit master Remove master n gt K Remove master select Edit master n t New master enter code Master code XXX mark selected select in sequence i Rights T Code Right description Rights enter name Name i4 b gt Master name XXX Read prox card Master name Erase prox card press key with 1 Read DALLAS Erase card 1 Yes
31. ection of access to the service mode and prevention of entering codes by unauthorised persons are main purposes of that An additional possibility is to assign specific control function to a code This function will be executed after the code is followed with the key see Description of User functions Users The installer using the service code defines administrator codes and names one administrator per each subsystem as well as he defines their rights The administrator has the right to enter ordinary system users He provides them with rights type and defines the partitions to which the users will have access Also the ordinary user may have the right to enter other users New user may have access to these functions and partitions only to which the user who enters the new code has access Note If the user has authorisation for changing the code he should change it after first usage of the code The control panel reminds by means of a message on the keypad display and an audible signal that this operation should be performed service setting The system stores the sequence order of entering users into memory The person with authorisation to enter and delete the users may remove from the memory the users entered by him her or his her subordinates only The service has the right to edit all administrators as well as to change codes The administrator has such rights for users in his her subsystem Ordinary users have rights t
32. el the timer type code Enter the second code Figure 9 Description of user functions 25 controlled arming until the particular timer is activated again Operation of this function pertains both to the Partition user timer and the Timers programmed by the installer The function makes it possible to select the partitions where the countdown of the auto arming delay has begun This very feature distinguishes the said function from the described below user function Set arming postponement which gives access to all the partitions armed automatically with time delay which are available to the individual user In view of a low value of the auto arming time max 255 seconds it is important that a quick option of the partition arming postponement be available in case it is necessary to stay inside Upon commencement of the countdown the control panel presents on the LCD keypad display the partition name and the delay time which remaines to arming If the time is simultaneously counted in a few partitions the display shows the name of the partition which will be armed first The postponement time is programmed individually for each partition for which the auto arming delay countdown has begun select partition code x Defer auto arm gt Partitio name n n m numbers of auto Partiti matically controlled artitio name m partitions enter tim
33. ently Upon starting the function the status of zones 1 32 is displayed Press any arrow key to move to the display of statuses for zones 33 64 to find a zone number add 32 to the number next to the symbol Press any arrow key to move to the display of statuses for zones 1 32 again The amount of Information accessible depends on the type of detector connected to the zone Detectors configured as double parameter provide most detailed information It is possible to read the following information of zones b zone bypass failure long violation f failure no violation S tamper alarm A alarm O zone tamper e zone violation s tamper alarm memory a alarm memory zone OK Note Symbols shown above are factory settings which may be changed The installer should inform on how individual zone and partition statuses will be marked on the display LCD keypad status checking the status of anti tamper contacts in the keypad casings Symbols displayed at the keypad screen are as follows correct status e contact violated X keypad replaced verification error keypad is missing Expander status checking the status of anti tamper contacts in expander casings first bus expanders and second bus expanders are checked separately On starting the function the status of the first expander bus is seen at the display LED marked 1 32 lights Press any arrow key to display status of the second bus expa
34. er bus 1 3 4 5 91 11 2 B 4 5 16 8 c Q scrolling names of partitions where alarm has been activated 8 when pressed for 3 seconds gong signalling in KEYPAD is switched on off keypad name when pressed for approximately 3 seconds o scrolling names of zones which triggered alarm when pressed for 3 seconds FIRE ALARM is activated when pressed for 3 seconds O when pressed for 3 PANIC ALARM is activated seconds auxiliary ALARM is 0 arming activated CODE arming disarming CODE call for the user function menu 4 XIGNAddV 0S ENUEJN Ses TALVS v9 V9
35. er is connected plus 8 DLrs keypad connected to the main board RS port accessible from the program DLOAD64 DLtl keypad connected to telephone line at the main board accessible from the program DLOAD64 efn n 0 63 expander module connected to the expander bus sjn n 1 32 partition win n 1 64 zone Tin n 1 64 timer 34 Usre s Manual CA 64 SATEL Tpar partition timer MnPI control panel main board Some of event descriptions allow readout of two identifiers for example partition number and zone number keypad number and user number etc To read the second identifier press one of keys change of the parameter displayed for the currently displayed event only or change of the parameter displayed for all events Next pressing of the key changes the identifier displayed to the previous one Either viewing of all events or viewing of selected events is possible Also you may choose partitions to be viewed The selection is made for partitions accessible for the user who called the function If the user wants to view selected events he has to mark at least one event type otherwise the menu function Viewing is not accessible see Figure 20 Marking of a partition is not necessary When the partitions are not marked the list of events from all partitions accessible for the user is displayed Selection of partitions influences the contents of the list displayed when viewing event types from
36. essing causes immediate arming or disarming if the partition is armed Typing code and pressing causes that the list of functions accessible from the User Menu is displayed From this menu also the functions of the following type may be accessed arming and disarming if some partitions are armed When all partitions are armed the function Arm will not be accessible As you can see in the examples described above the control panel in an intelligent way makes accessible those functions only which may be executed by a specific user All user functions which are accessible from LCD keypad are described in section Description of User Functions SELECTION OF FUNCTION When the control panel accepts the code the first user function from all functions accessible currently appear in the upper line of the display You can move through the list of functions rendered accessible by the control panel by pressing key and Y and select the item in the list single selection list by pressing the key or gt If the selected function requires making further selection submenu options the next list appears on the display from which you can select required item in a similar way Some functions may need selection of few items from the list multi selection list To do that scroll the list by pressing and Y key and mark all items in the list which should be selected The item is marked by pressing any numeric key the symb
37. f partitions This function may be accessible from an LCD keypad and a partition keypad When called from an LCD keypad the function may arm several partitions and when called from a partition keypad it may arm only this partition to which the partition keypad is assigned Moreover keeping depressed the key marked 4 displays LCD keypad name and depressing two key and Y for approximately 40 seconds causes the keypad processor to restart and display the keypad software version number and the control panel software version number 6 User s Manual CA 64 SATEL LCD KEYPAD 1 2 3 4 5 6 7 8 9 0 11 2 B 4 5 16 CA 64 10 A lt e gt 2001 Sarel 17 18 9 21223 24 25 2 27 28 29 30 31 32 12 0 7 ZONES 164 36 0 ESENES ZIEN JLo JUFJLYJ Figure 1 An LCD keypad is provided with a large LCD display 2 x 16 characters with permanent or temporary backlighting the latter is activated either by pressing any key or by violation of any zone service setting 16 keys lighted similarly to the keypad screen are located beneath the display which are used for entering the code moving along menu and selecting appropriate functions from the list entering data for functions called Six LEDs are located at the right hand side of the display to indicate current system status e ALARM red continuous light informs on alarm signalling activation at this moment When the LED blinks it means that in part
38. f this type Bistable output code which changes the status of the Bl switch type outputs when used This function may be executed in partitions assigned to a code of this type Note The control panel makes possible to define outputs used for controlling equipment of different types for which access must be controlled Such control is carried out by means of codes Monostable output and Bistable output The installer should inform the user about devices controlled this way Temporary partition bypassing code which de activates partition detectors for a certain time period assigned to the code when the partition is armed After this user code type is chosen when entering or editing function bypass period 30 Usre s Manual CA 64 SATEL appears in menu see Figure 16 where partition bypass time period should be defined 9 Access to cash point code which activates the procedure of access to a cash point Cash point is protected 24 hours per day but activities connected with the cash point service need detectors to be bypassed The control panel automatically restores detector activation after a strictly determined time service setting 10 Sentry global code which may be used for making rounds by sentries in the whole system Typing this code CODE into the keypad at the partition to which the specific user has access generates an event Sentry Round and eventually activates part
39. ge by the user is another additional partition keypad function service setting User partition change is carried out as follows Press and keep depressed for approximately 3 seconds the key with digit 1 LEDs ALARM and ARMED red and green start to flash alternately Type the old CODE and press LEDs ALARM and FAILURE red and yellow start to flash alternately Type new CODE and press LEDs stop blinking and the module generates confirmation signal of function execution In the following four cases the control panel cannot accept the change of code it is signalled with two long beeps 1 the new code is too short or too long accepteble are codes of lengthfrom 4 to 8 digits 2 the new code is too simple the function of refusal of simple codes is activated 3 the new code is identical with a code of another user of the alarm system Someone s code has been guessed 4 change of the code has been blocked because another user guessed thecode trying to change his own code If the function of reminding about the necessity of code change is activated each usage of such a guessed code will be signalled with three double beeps In this event the change of the code will be possible only by means of the LCD keypad with the requirement of confirmation of the code change see the description of the function change own code by the administrator of the subsystem It makes impossible to take over th
40. h event description in words zone module and partition 4 User s Manual CA 64 SATEL name or name of the user who operates the system together with accurate time of the event occurrence e control and monitoring up to 8 independent alarm subsystems and up to 32 partitions armed independently e control of individual system parts from independent keyboards maximum 8 LCD keypads and 64 partition LED keypads e control and supervision of the system by means of a computer program GUARD64 e dynamically changing menu dependent on access level to provide access to a range of user functions the selection is made by accepting the function at the list shown in the LCD keypad screen e key short cuts to facilitate calling frequently used functions OPERATION OF CONTROL PANEL CA 64 LCD keypads and partition keypads are used for operation of alarm system based on control panel CA 64 Moreover the control panel supervises and registers usage of code locks and proximity card as well as Dallas chip readers located adjacent to doors in individual rooms of an object Partition keypads may be also used as code locks Individual control devices are assigned to selected partitions by the installer LCD keypads may operate many partitions of different subsystems Partition LED keypads operate a single partition only Individual users may operate the control panel when they are provided with access to partitions operated by specific keypads T
41. hat means the partitions assigned to the user at the stage of a new user creation or edition see Description of User Functions gt Users must correspond to partitions operated by a keypad The installer defines the list of partitions operated by individual LCD keypads Example A LCD keypad controls operation of partitions 1 2 3 4 5 and 6 The user has access to partitions 5 6 7 and 8 It is seen from comparison that by using this LCD keypad the user may control operation of partitions 5 and 6 A similar rule applies to partition LED keypads code locks and proximity card readers With keypads the user may control these partition to which he has access he may open these doors with code locks and proximity card or DALLAS chip readers for opening of which he has been authorized The installer defines the list of users of individual partition keypads coded locks and proximity card readers separately for each module The access to functions controlling the operation of the control panel and more important information on the system status are protected with a CODE code combination of 4 to 8 digits It is possibile to obtain some information on system and call some functions without using a code service setting by keeping depressed one of the following keys for a longer time approximately 3 seconds Operation of control panel CA 64 5 v zones status viewing keypad tampering viewing expander tampering vie
42. he way of signallisation of individual alarms may be different and it is defined by the system installer It may be an alarm buzzer information to a monitoring station visual alarm audible alarm and or keypad message telephone message activation of other external devices MESSAGING ON ALARM BY TELEPHONE The telephone communicator integrated in the control panel CA 64 allows transmission of information on alarm through the telephone line to any telephone number The message transmitted may be adapted to the alarm type the system 18 User s Manual CA 64 SATEL installer may install voice synthesizers to allow up to 16 messages to be replayed The installer defines who and on which alarm will be informed by the control panel by programming relevant telephone numbers and defining rules of messaging Also the control panel may transmit the information on missing 220 V power supply in the form of voice message or pager message Power supply failure is a serious danger for the protected object and the alarm system therefore this information has been recognised as equally important as information on alarms The person whom the control panel calls may confirm message receipt Special code is used for that programmed by the installer individually for each telephone number When the message is not confirmed the control panel may repeat the message transmission number of repetitions is programmed by the installer The telephone set m
43. iming to block it Additionally three sequential trials to call programming from outside block the mechanism of answering to modem signals for 30 minutes DESCRIPTION OF USER FUNCTIONS MAIN MENU The list of functions accessible from LCD keypad is shown in Table 1 First table column contains names of functions and specific function properties are given in the second column There are functions accessible for the service only and one function is accessible for the administrator only The functions are described by means of block diagrams see Figures below Function names are extended with function properties as in Table 1 Some functions are present in the menu alternately only one of such functions for example Service mode and SM take over is accessible at the moment Pairs of functions of this type are marked with a bold line section at the left hand side part of table frame function name column Symbols in column PROPERTIES table 1 t function has submenu multi selection function XXX function requires data to be entered code name time graph graphical mode of zone partition and module information display is accessible service function accessible for the service only master function accessible for the master administrator only Description of user functions 21 Clear alarm Clearotheralarms Abortvoicemessaging Arm 2 codes ge Arming mode Change own code XXX
44. ition bypass Typing of this code into an electric lock keypad or access trial by means of a proximity card or DALLAS chip generates the event the User Access type When the sentry is provided with access to partitions the partitions may be controlled in a way similar to the control with a normal code Typing of the sentry code the use of a sentry card or DALLAS chip at the equipment assigned to the partition where a sentry round is programmed starts counting down the time to the next sentry round from the beginning The installer defines the keypads with the use of which the sentry should type his code when performing sentry round in the protected object and maximum time period between subsequent sentry rounds The time period between sentry rounds is determined for each partition individually both when the partition is armed and disarmed It is also possible to plan the sentry round in one of situations described above only for example when the partition is armed Missing sentry round generates the event alarm no sentry which may be signalled at one of control panel outputs Save Description of user functions 31 code x Users select New user lect Edit user se m gt User name T Remove user select gt User name K type code User code XXX typ
45. itions accessible for this user Also the user may control the status of control panel relay outputs programmed as telephone relays The installer has a possibility to program up to 16 telephone relays Also the installer decides which relays may be controlled by individual users To use this function of the control panel you must have the telephone set operating in DTMF tone system Note Not all cellular telephones allow control in DTMF tone system How to use this function Dial the telephone number line of the control panel The way of dialling is defined by the installer The control panel may communicate after a defined number of dialling signals rings Dialling may be single or double When double dialling is used wait a defined number of rings put the handset off and then dial the control panel telephone number again After the number is dialled the second time the control panel should answer immediately Operation of control panel CA 64 19 After the communication is started the control panel is ready to receive the user telephone code three short beeps prompt Type code at the telephone set keypad in the tone system The control panel accepts the correct code with series of beeps four short and a single long one An incorrect code is followed with two long beeps Now the control panel operates in the mode of informing on partition status It waits for user s response for 15 seconds and genera
46. itions operated with this keypad alarm signalling occurred again since the last reset of the alarm memory e FAILURE yellow the LED blinking informs on presence of a technical problem in the system Failures which activate this LED are described further in this Manual see Description of User Functions gt Failures The LED does not light when the LCD keypad operates in partially armed mode at least one partition accessible for the LCD keypad is armed or armed mode all partitions accessible for the LCD keypad are armed service setting e ARMED green the LED blinks when some partitions are armed and lights steadily when all partitions operated by the keypad are armed e SERVICE green the LED blinks when the control panel operated in the service mode function accessible for the user provided with the service code only Note Service mode limits normal operation of the control panel Alarms from most of zones except for zones of the following types attack cash point and vibrating and tampering alarms are not signalled In order to restore the normal control panel operation mode just exit the service mode for the control panel does not return to its normal operation mode automatically Operation of control panel CA 64 7 e Zones 1 64 two green LEDs they are used when viewing and testing status of zones and expander type modules they indicate which group of zones or which expander bus is currently dis
47. lock it is necessary to close the dependent door and reenter the code Blinking of the back lit may substitute the audible signalling service setting Beeps correspond to keypad lighting off pulses when the lighting is on or light on pulses when normally it is off Also the partition keypad may indicate alarm occurrence in the partition concerned service setting Alarm in the partition steady sound for total alarm duration Alarm memory long sounds every two seconds until alarm is reset The sounds are synchronised with ALARM LED flashing Press any numeric key to silent the sounds for approximately 40 seconds Fire alarm a series of long sounds every second for total alarm duration Fire alarm memory short sounds every two seconds until alarm is reset The sounds are synchronised with ALARM LED blinking Press any numeric key for approximately 40 seconds to silent the sounds Count down of time for entering short sounds every 3 seconds Signaling the auto arming delay time countdown timer controlled partitions a series of 7 sounds of diminishing length Door are open for too long short beeps repeated with high frequency till the door are closed the function of door control is activated Operation of the system from the partition keypad is very limited and it relates to the partition to which the keypad has been assigned by the installer There is a possibility to operate an electromag
48. lose to the card reader and hold it there for approximately 0 5 sec The distance between the card and reader when reading may be up to 12 14 centimetres depending on reading head type DALLAS chip should be pushed into the head slot to close the zone electric circuit The control panel receives the code from the expander operating the reading head recognises the user to whom the card or chip is assigned and operates according to settings programmed when the user has authorisation to open the door to activate the relay In the alarm system CA 64 the proximity card reader signals have the following meaning DALLAS head may generate identical signals Meaning of audible signals generated after proximity card readout single short beep card code readout Two short beeps start of card code writing function confirmation of first writing Two long beeps control panel have not recognised the card Three long beeps card code is recognised but the user has no access to the lock relay control 14 User s Manual CA 64 SATEL Four short beeps and one long beep card code accepted the relay activation second correct readout of a new user card Five short beeps dependent door open relay has not been activated Short beeps without time limitation door opened for a too long period Meaning of visual signals emitted during armed status and after proximity card code readout LED blink
49. meric LCD keypad Each function is described in detail and shown in a block diagram The text in this Manual contains some technical terms please use APPENDIX C at the end of Manual for explanation This Manual refers to the control panel program version 1 03 12 and the DLOAD64 installers program version 1 03 15 up to date on the day of preparation hereof 2 User s Manual CA 64 SATEL CONTENTS INTRODUEFION G iz ORO GOA E AA OOO AO 3 OPERATION OF CONTROL PANEL CA 64 0200 2002000o0000000o0000ooeooooaooe ow owao wo ow owao wo oa wdowa ow owa owo od owao wod o0a0 000 4 BASIC INFORMATION ua dias 4 LEDIKEY PAD co aida 6 THE USE OF LED KEYPAD oa 7 PARTITION KEY PAD yw cease need ices teeta tence hea ost 10 CODE LOCK a eee ee 12 PROXIMITY CARD AND DALLAS CHIP READER cooooococoonconoononnonncononnnonconnonnonconncononnnonnon rra nono rra naar reinos 13 CODES AND USERS hepe EE A r TE E dos 14 SYSTEM ARMING is 15 ALARMS dd et bes ab 17 MESSAGING ON ALARM BY TELEPHONE cccccessessesseseeseeseesecseeseceseneeseceaecacsaecaesaecaeeecaaeesesaeenenaeenees 17 ANSWERING PHONE CALLS gee a W A ADR AE ds 18 OTHER FUNCTIONS USING TELEPHONE LINE ee eee eee eee aaa aaa aaa area oaza wazna ea acaae 19 DESCRIPTION OF USER FUNCTIONS 2 02 0 0 0000 00000o0o0eowooeoweoeowao wo oe ow ao wo oe ow ao wo oe owad wo oe owa owsa wan wood owa0 wwo 20 MAIN MENU tei O EEE O GS A ORC MAG Ao
50. nders LED marked 33 64 will light Symbols displayed at the keypad screen are as follows correct status e contact violated X expander replaced verification error _ expander is missing 38 Usre s Manual CA 64 SATEL Supply voltages checking power supply voltage level for individual expanders The display shows the expander name and approximate power supply voltage level for this expander Zone Test the function allows to check which of control panel zones used are violated when the test is carried out After the function is called the display shows the text New press key or gt to start the function of registration of zone violations Subsequent calling of this function by the same user makes accessible the function Test result viewing press key or gt to open the list containing the number of zone zone name and information on whether it was violated at least once during the time the test was carried out Next pressing of the key gt changes the descriptive mode of the test result display to the graphical mode In the latter mode the following information is displayed zone was not violated zone was violated The duration of the test is unlimited Test results are accessible for the user who started the function The user is allowed to test the zones in these partitions to which he has access Note Calling the new test function by the user cancels the test previously started b
51. ne call OTHER FUNCTIONS USING TELEPHONE LINE If the alarm system uses functions of the control panel telephone communicator the line from the local exchange to the object is connected directly to the control panel and all telephone sets are located downstream the control panel Therefore no signals are heard in telephone sets when the control panel uses the telephone line This situation may occur frequently in multi partition system where monitoring is activated Moreover the control panel will disconnect the telephone conversation when taking over the telephone line in order to transmit an information on a new event It should be said that control panel phone calls do not last for a long time from several to tens seconds depending on the selected format data transmission Another function where the control panel occupies the telephone line is programming by the telephone downloading This function may be initiated by the service The telephone line may be occupied for a long time when data are transmitted Even if the programming is initiated by the user the service may hold communication with the control panel for cost saving reasons and then restore it without engaging the user 20 User s Manual CA 64 SATEL Note Access to the control panel in programming mode by telephone is protected with ten byte code more than 1 2x10 combinations This is a very good protection against hacking to the control panel by telephone a
52. netic door lock from the partition keypad by means of the user s code Several partition keypads may be assigned to a single partition Functions accessible from the keypad are as follows gt CODE arming and disarming of partition and alarm reset gt CODE x electromagnetic door lock opening Similarly to the LCD keypad the user who wants to start functions mentioned above need to have access to the partition concerned and proper authorisation Besides he need to be authorised to use the partition keypad concerned these rights are assigned by the administrator with in the GUARD64 program or the installer service in the DLOAD64 program When the erratic code is typed three times the alarm may be activated service setting Other functions accessible from the partition keypad without code entering are as follows gt 04 quick partition arming and functions of calling special alarms w panic alarm 0 auxiliary alarm calling for medical aid 7 x fire alarm The last three functions are started by longer keeping depressed for approximately 3 seconds the key described above 12 User s Manual CA 64 SATEL Note When arming is on for the partition and the partition keypad also controls the electromagnetic door lock typing CODE causes disarming and door opening if the partition is not bypassed temporarily However If the user has no authorisation for disarming the door remains closed Code chan
53. not know the system very well Also taking into account the safety of the object it is not recommended that most of users have access to all control panel functions The system incorporates the hierarchy system for access to the control panel functions and partitions defined for the object by the installer Generally typing at the keyboard gt CODE gives access to functions of arming disarming type gt CODE x gives access to all functions in the User Menu to which the user is authorised Note When an erratic code not recognised by the control panel is typed three times the alarm will be activated service setting The list of the control panel functions for user access is formed in a dynamical way The contents of the list depends on system parameters code type user authorisation and alarm system status and situation Example When you type your code and press the control panel makes accessible functions of partition arming provided there are no partitions operated from the LCD keypad already armed or disarming if any of partitions is armed In the event of alarm occurrance in the system the control panel may cancel this alarm and make accessible the function of partition disarming if the user has authorisation to do that When the function of messaging by telephone is activated function Cancel messaging by telephone may appear in menu When the user has access to a single partition only typing the code and pr
54. ntrol panel in determination which partitions may be armed at the moment is its great advantage BASIC FUNCTIONS OF THE CONTROL PANEL e signalling burglary attack fire technical and auxiliary alarms e monitoring communication with telephone monitoring stations real time sending detailed information on selected events in the protected object e messaging on alarm by telephone either with the use of a vocal message or toa pager e answering phone calls this function is protected with a separate code that makes possible to inform the user on a system status to control some of the control panel functions via telephone these functions are programmed by the service e real time printout of information on all or selected events occurred in the alarm system e supervision of access to rooms through doors provided with electromagnetic locks e monitoring the correctness of operation of individual alarm system components power supplies batteries wiring CONTROL PANEL USAGE PROPERTIES e operation by means of keypads provided with LCD text display 2x16 characters to facilitate the use of the system e descriptions of zones and partitions defined by the installer make easy to find the alarm source e visible date and time of the system clock allow controlling the correctness of functions that depend on the real time e accessible are viewing the alarm memory and failure memory or detailed memory of all events wit
55. o bypassed zones The function is used in case of a detector failure or its incorrect operation It gives the possibility to arm the system ignoring the bypassed zones The bypass entered with this function is cancelled after disarming Also zone bypass may be de activated with the use of this function Proceed in a way reverse to bypassing of zones remove marking of zones marked The installer defines zones which cannot be bypassed with this function mark selected code x P Zone bypasses Zone bypass n QU gt K Zone name n number of a zone in the system Figure 17 SET TIME The function makes possible to enter the actual time and date to the alarm system This data are entered in the following format time HH mm SS hour minute secona date DD MM YYYY day month year New data are entered by typing the correct digit at the place of the cursor flashing After entering the digit the flashing indicator moves to the next position on the right Also it may be moved with the use of keys and type time code Set time gt Set time XXX HH mm SS type date Set date XXX gt gt K DD MM YYYY Figure 18 Description of user functions 33 FAILURES The function makes possible to scroll the list of failures occurred in the alarm system It is accessible only when FAILURE LED flashes at the LCD keypad and partiti
56. o edit the users they entered This possibility is convenient when the code is lost The supervisor of the user concerned may enter a new code and make controlling the system available for him of course within the range limited by his authorisation The control panel assigns numbers to the users to identify them in the system This number is used in messages transmitted to the monitoring station and in event descriptions see Description of User functions Event history SYSTEM ARMING Armed is the basic status for which the control panel was designed In this mode the control panel detectors monitor the protected object and any violation of the protected partition is signalled by the control panel with all means accessible programmed by the installer Control panel CA 64 enables individual control of armed status in each partition A single partition several partitions and all partitions may be in armed status Each partition may be disarmed individually by means of partition keypad LCD keypad or totally LCD keypad 16 User s Manual CA 64 SATEL Typing the following at the keypad is a normal way of arming gt CODE partition keypad arms a single partition and keypad gives the possibility to arm all or selected partitions accessible gt 04 quick arming the partition keypad arms a single partition and keypad arms partitions programmed by the installer no selection possible If one of partitions accessibl
57. ol appears in the upper display corner next to the text Press the numeric key again to cancel marking By scrolling the list upward or downwards list contents is displayed in a cyclic way you can see all list items and check marking Pressing the key or gt accepts the selection execution of function may be confirmed with beeping and the control Operation of control panel CA 64 9 panel returns to previously displayed menu or displays the adequate message and returns to the basic status waiting for code Then current date and time is displayed Date and time display format is defined by the installer service setting There is the control panel setting option which activates the procedure of double acceptance of some user functions After pressing the key or gt normal way of selection of function the prompt appears on the screen asking to confirm the function together with information 1 Yes Press the key with digit 1 to confirm this function This procedure protects against accidental double pressing the key or gt and execution of function which should not be executed The description of user functions in this Manual relates to situation when this option is switched off If you want to abandon the selection of function after opening the User Menu press key In the event no keypad button is pressed within 2 minutes after menu opening the control panel automatically closes this menu and returns to its basic sta
58. on keypads You can find the list of possible failure messages at the end of this Manual APPENDIX A The name of element concerned entered by the installer appears in messages related to zones expanders and keypads in bottom line of the display No additional message is displayed at the end of this function NOTE Inform the service person immediately in the event of any failure in the system and remove the cause of the failure alarm press to end code Failures Message t Name Figure 19 EVENTS The function makes possible to scroll the list of events stored in the control panel memory The events are given in the sequence order of their occurrence The event description contains data displayed in the following format see Figure 20 date DD MM day month time HH mm hour minute identifier xxxx four characters IDEN which identifies the number of zone partition module user operating the system special symbol Event name text in second display line Description of meaning of identifiers Ser user service code Adm n n 1 8 user subsystem administrator code ujn n 1 192 ordinary user of the system mjn n 0 15 keypad module connected to the keypad bus or virtual keypad accessible from the program GUARD64 0 7 nos of keypads in the system 8 15 nos of keypads accessible from the program GUARD64 defined as follows no of keypad to which the user comput
59. on mode the control panel programming is possible with the use of program DLOAD64 via RS port at the main board and via the telephone line The control panel remains in the service mode until exiting it with function End of SM service mode entry in the list of service functions or until the time limit given by the administrator elapses 40 Usre s Manual CA 64 SATEL The function is accessible after unlocking service access by the administrator and entering the service code SM TAKE OVER The function makes possible to switch over the operation control of the control panel being in the service mode to the keypad other than the one from which the service mode has been called The function is accessible for service only It is intended for use in large objects where several keypads are installed the function facilitates installer work DOWNLOADING The function which starts communication with the service computer It allows installer to program the alarm system by means of the computer and the service program DLOAD64 It is possible to start direct communication via RS port as well as indirect communication via the telephone line with the use of either external or internal modem To start a telephone call it is necessary to program the service computer telephone number select code x Downloading Start DWNL RS service K Finish DWNL RS _ service Start DWNL TEL Fig
60. oor opening gt CODE x door locking When gt erratic code is typed three times the alarm may be activated service setting It is possible to call special alarms using a code lock keypad These three functions are called by longer keeping depressed for approximately 3 seconds the key A panic alarm 0 auxiliary alarm calling for medical aid 7 x fire alarm Confirmation of the function called by the control panel with sound or blinking is identical as for partition keypad PROXIMITY CARD AND DALLAS CHIP READER Proximity card and DALLAS chip readers have the same role to play in the system as code locks Proximity card readers are provided with two colour LED and buzzer for communication of the control panel with the user DALLAS chip heads are not provided with any signalling of this type but the installer has a possibility to provide such an external signalling Each alarm system CA 64 user administrator sentry ordinary user may be assigned with one proximity card and or DALLAS chip at the stage of user creation or edition Also it is possible to remove the previously assigned card chip to a user from the control panel memory In order to provide a new user with a card chip with a code already known to the control panel first remove this card chip from memory see USER MANUAL CA 64 gt Description of user functions gt Users and then assign it to another user Use the card as follows bring the card c
61. part II below 44 User s Manual CA 64 SATEL Function Activate selected marked or Calling the function 12 3 4 5 6 78 9 01 2 B 4 5 Miro FET or Scroll the list with partition names Press one Storeroom of these keys so many times as you need to display the name of the partition required partition 2 Book keeping 17 1819 2122324 52 2 28 2 30 31 CONTROL PANEL 12 07 64 zones p After the function is called the control panel displays partition names factory set or entered by the installer which the user may arm Press key to move to the graphical mode of partition selection 12 3 4 5 6 78 9 011 12 B 4 5 3 Mark the partition selected for arming l mark at the right hand side of the display using any p What to SLNN numeric key BOOk keeping 17 1819 02122324 25 2 2 22 2 30 31 CONTROL PANEL 12 0 gt You may select for arming mark any number of partitions accessible to you Also you may cancel marking for partitions selected earlier End of selection and arming of all marked ae a partitions System armed 7189021234 5627 728230 31 CONTROL PANEL 1 32 Q j ZONES m When this message appears counting down time for leaving is started in the armed partitions GRAPHICAL MODE There are two ways of selecting the partitions for arming using names as described above using pa
62. played on the LCD keypad screen see Description of User Functions gt Tests In addition to visual signals the LCD keypad may generate audible information service setting The following signals specific to some situations may be heard when using the keys One long beep refusal of arming the zone which shouldn t be violated at the time of arming is violated option PRIORITY The refusal includes all zones selected for arming Two long beeps the control panel did not recognise the code function is not accessible erratic data confirmation of abandoning the selected function after pressing on the keypad keyboard the key pressed is not active Three long beeps the code is recognised but the called function is not accessible for example temporary partition bypass is activated or the user has no access to partitions operated from the keypad the zone which should not be violated when being armed is violated refusal of arming Two short beeps selection accepted entering more detailed menu level Three short beeps confirmation of arming or disarming Four short beeps and one long beep acceptance of execution of the selected function Three pairs of short beeps it is necessary to change the code for example another user when changing his code has given an identical combination of digits as the combination in the code of the user the code validity is expiring Moreover
63. ple NOTE When all partitions accessible for you are armed the function Arm will not be shown in the menu on the keypad display If some partitions in the subsystem are already armed the following texts will appear on the display 12 3 4 5 6 78 9 0 L 2B 4 5 ALARI gt Disarm F Arm mo O SERWCE O 17 1819 0212 23 24 25 2 27 22 2 30 31 CONTROL PANEL 12 07 CA ZONES In this situation perform as follows Indication of the function Arm Hor Select the function marked with arrow Whot to arm moving to the stage of partition selection tor storeroom arming as described in details in the first part of this example If we assume in this example that the partition 2 Book keeping has been already armed after calling the function Arm again and entering the graphical mode of partition selection the following display will be shown Now partitions 1 3 and 4 may be armed 46 Example 2 NOTE 11114 NOTE or or User s Manual CA 64 SATEL DISARMING part I Partition No 2 named Book keeping belonging to the subsystem 1 user the subsystem master The function is available only when at least one of partitions accessible for the user is armed Enter the user code factory set administrator code for the subsystem 1 Also you can enter the code of any user who has access to partition 2 and authorisation for disarm
64. r disarming mark any number of partitions accessible for you Also you may remove marking for partitions selected earlier 12 3 4 5 6 7 8 9 0 I 2B 4 5 End of selection and disarming iof all partitions marked Appendices 1111 Hor NOTE ARMING part Il 47 with the use of all user function menus accessible Type code calling the user function menu Select the function marked with arrow moving to the stage of partition selection for disarming as described in detail in the first part of this example 12 3 4 5 6 778 9 0 1 2B 4 SE _ gt Disarm Change ovn code 17 1819 2122324 52 2 28 2 30 31 CONTROL PANEL 1 32 0 ZONES a 123456 78 9MDURBHM 5 What to disarm Workrocm il 17 1819 0212 23 24 2 2 27 28 229 30 31 CONTROL PANEL 12 07 ZONES 164 34 03 If only some partitions in the subsystem are armed the following texts appear at the display 12 3 4 5 6 78 9 01 2 B 4 B _ gt Disarm Arm 17 1819 2122324 52 2 28 2 30 31 CONTROL PANEL 132 0 64 zones p Performance in this situation should be identical as when all partitions are armed If we assume data from the example presented earlier the following picture may be shown at the keypad screen being in the graphical mode of partition selection 12 3 4 5 6 78 9 01 2 B 4 SE 17 1819 2122324 52 2 28 2 39 31 CONTRO
65. rtition numbers in the graphical mode described below This is the mode for the user who knows numbers of partitions in the alarm system or the user who wants to check quickly how many of zones are not armed yet 12 3 4 5 6 78 9 01 2 B 4 SE TS These keys are used to select partitions in the graphical mode These keys are used to select partitions in 17 1819 2222324 52 27 28 2 39 31 CONTROL PANEL 1 32 0 ZONES the basic mode using partition names It is possible to switch over between modes as many times as necessary p Dots next to numbers 1 32 indicate partitions which may be armed 1 2 3 and 4 The cursor under a dot allows to select the partition which may be marked for arming Appendices 45 12 3 4 5 6 78 9 0 L RBH 5 Move cursor under the 2 partition field 3 Mark the partition for arming with any numeric key 17 1819 22223 4 52 2 28 29 30 31 CONTROL PANEL 12 0 gt 64 zones p Pressing the key after selection of partition makes it armed independently of the display mode ARMING part Il with the use of all user function menus accessible 12 3 4 5 6 78 9 0 L RBH 5 1111 Type code calling the user function menu Hor Select the function marked with arrow Change own codel a o moving to the stage of partition selection for E NZ arming as described in details in the first part ire e of this exam
66. s red in a uniform way missing communication with control panel this situation may occur when the special system initialisation program STARTER is running in the control panel the reader module has not been identified or the cable connecting the module to the control panel is damaged LED lights red steadily module is correct lock operation relay control is possible LED changes colour from red to green once a second 2 single short changes waiting for first card reading double short changes waiting for second reading of a new card The installer may activate the option of confirming with a LED the messages sent from the control panel to the user In this case after the card is read the change of LED colour from red to green goes on in accordance with audible signalling described above CODES AND USERS The functions of control panel operation is possible after entering a proper code and pressing key or Three basic code types are used 1 Service code this code identifies the user with special rights he controls all partitions he may open all doors controlled by the control panel he has access to most of control panel functions except for the Service access and Users functions see Description of User Functions he may enter and delete subsystem administrators Factory programmed service code 12345 2 Administrator supervisor code this code identifies the user with highes
67. stalled by the installer The control panel may perform its functions in many ways which are defined when installing the system and its software Due to the above the installer should give you more detailed information regarding the operation of the alarm system and procedures of its using All situations where the way of the control panel operation depends on previous installer decisions made at the time of programming are additionally marked with text in brackets service setting following the description of situation The term service used in this Manual relates to the user who maintains and takes care about the alarm system and uses the service code see page 12 It may be the installer maintenance person the employee caring for protection of the object etc ABOUT THIS MANUAL This Manual describes the basic operation of modules used for controlling the system operation as well as the control panel functions The first part of this Manual titled Operation of Control Panel CA 64 contains descriptions of modules used for controlling the operation of the control panel and their way of use Also some functions related to the alarm system operation are described here Furthermore included are the basic information on system functioning and use of the telephone line by the control panel The second part of this Manual titled Description of user functions contains full specification of functions accessible from alphanu
68. t authorisation for subsystem The administrator has access to all partitions within his subsystem There is a function which unlocks the service access see Description of User Functions Service access level This function is always accessible for the administrator and not for the service Factory programmed administrator code for a first subsystem 1111 Other administrator rights may be limited by the service installer If few subsystems are defined in the system each subsystem has its own administrator code This user has the right to enter new users into the system 3 User code the remaining codes entered to the system by administrators or users with rights to edit the user These are the codes for everyday operation of the system 192 user codes may be entered in the CA 64 control panel Operation of control panel CA 64 15 Notes Service code is rejected by the control panel when service access is locked The administrator may unlock the service access to the alarm system by using the function Service access see Description of the User functions If there is no administrator code in the system all administrators are removed service access to the system is unlimited It is recommended not to use the administrator code everyday unauthorised persons may peep the code The administrator should enter an ordinary user code with strategic functions blocked and he should use it in everyday work Prot
69. t of possible event messages Event name is at the end of this Manual in APPENDIX B RESET ZONES The function forces short voltage loss at detector power supply outputs with activation memory for example fire detectors This operation clears detector memories If few identical detectors are connected to a single output the activation memory allows finding the detector which triggered the alarm code x gt Reset zones _ P _K Figure 21 CHANGE OPTIONS This function controls the GONG type signalling and allows setting partition user timer which automatically armes and disarms Gong in keypad signals the violation of any zone detector selected by the installer Few zones may be selected and they will activate signalling in the keypad The gong signal in each keypad may be activated from different zones The function makes possible to block and unblock the signalling mentioned above in the keypad in which it was called Gong from output there is a possibility to configure the output intended for signalling the violation of selected zones This output generates signals a control panel zone violation with the marked option Gong control It is possible to block or unblock activation of such signals for individual partition outputs separately Partition user timer see section SYSTEM ARMED allows automatic zone arming and disarming 1 To enable timer operation mark the parameter Activ
70. tes one short beep every two seconds Now It is required to enter the partition number at the telephone set keypad two digits for example 01 05 12 25 If the user does not respond within this time the control panel will ring off After the partition number is entered the control panel generates the message Three short beeps inform that the partition is disarmed and four short and one long beeps mean that the partition is armed Alarm memory is an additional information given by the control panel If an alarm occurred in the partition the control panel generates series of double beeps first is lower and second is higher following the information on the partition status Where no alarm occurred the control panel generates single short beep every two seconds In order to move to the control mode of the telephone relays status press 2 and at the telephone set keypad Now the control panel waits for the relay number two digits To trigger the relay status to the reverse one type the relay number at the telephone set keypad Two short beeps mean that the relay has been switched off and four short beeps and one long beep mean that the relay has been switched on Each time you type the relay number you change its status to the reverse one You may move back to the partition status indication mode by pressing keys 1 and one after one When you press keys 0 and one by one you exit the function and terminates the pho
71. the user select code Arm all mark selected K Arm selected What to arm partition name graph code gt Arm Figure 7 ARM 2 CODES The function arms special partitions Two different codes must be used to arm them The presence of such partitions is declared programmed by the installer The second code must be entered within 40 seconds after entering the first one after that time the control panel returns to the basic menu select partition code Arm 2 codes _ Partition name g type code Enter the XXX Ls k second code Figure 8 DISARM 2 CODES The function disarms in special partitions Two different codes must be used to disarm them The presence of such partitions is declared programmed by the installer The second code must be entered within 40 seconds after entering the first one after that time the control panel returns to the basic menu select partition code gt Disarm 2 codes gt Partition name g DEFER AUTO ARM The function puts off delays the arming of a timer controlled partition auto arming It is intended for programming the value of time interval by which the moment of automatic arming of a partition is to be delayed The maximum postponement time value is 4 hours 33 minutes and 3 seconds Entering a higher value will set the maximum permissible value while entering the zeros alone will canc
72. tus GRAPHICAL MODE Partition selection functions allow also another way of multiple selection from the list for example selection of partitions for arming It is called a graphical mode When you have already entered the selection list press key gt or to enter this mode Dots under the number of each accessible partition numbers 1 32 around the display appear on the keypad screen The dash under the dot cursor indicates which item may be marked Use key gt and to move the cursor to the item required Pressing any numeric key causes the symbol W to appear at the item selected Press the numeric key again to cancel marking Press key f or 4 to restore the previous way of display with name ALARM SOURCE NAME READING The installer may also render accessible the function of displaying the name of the alarm source at the LCD keypad screen without necessity of entering the code In such an event the partition or zone name is displayed at the keypad screen when an alarm occurs When there are few alarm causes you may scroll zone names for which alarm occurred and names of partitions where the alarm is or has been signalled Arrow keys and allow viewing partition names if an alarm occurred for few partitions and keys ft and Y allow viewing zone names for which an alarm occurred These names entered initially by the installer are displayed in a cyclic way in the lower display line and they are shown in numeric or
73. type for a partition this timer may be programmed in daily or weekly cycle see Description of User functions gt Change of option e partition arming control by means of a special zone programmed by the installer as arming control zone In practice it may be a mechanical switch key switch pushbutton radio switch Also such a zone may be controlled via telephone with the use of DTMF system see Answering phone call ALARMS The system may signal alarms as the response for various situations occurred in the protected object Basic control panel alarms are as follows e Burglary alarm activated when the zone is violated in the partition where arming is on The violation of the delayed zone starts to count down the delay time after which alarm is activated if the partition will not be disarmed e Fire alarm activated by fire detectors from keypad or in another way for example pressing the pushbutton e Tampering alarm activated by violation of any anti tampering contacts in the alarm system located in detector and module casings damage to cable s etc e Attack alarm activated from keypad or in another way defined by the installer for example pushbutton e Auxiliary alarm activated from keypad for example call for medical aid or in another way defined by the installer for example remote controller or pushbutton e Technical alarm activated by various specialist detectors T
74. u may switch over between Z0N sets as many times as needed End of function 17 1819 2222324 52 2 28 2 30 31 CONTROL PANEL 1 32 Q j ZONES 14 3044 The LED 33 64 being ON indicates the set of 33 64 zones the status of which is shown on the display Add 32 to the number next to the zone symbol numbers around the display to obtain the zone number Functions of LCD keypad keys and LEDs see pages 4 7 for detailed description 1 to 6 keep pressed for 3 seconds LCD DISPLAY date ALARM FAILURE signals that the technical to get access to the viewing and time steady light alarm in the problem has been detected in the system functions operated partition check by pressing the key for3 blinking light alarm seconds memory for the partition 1 zone status viewing 2 keypad tampers viewing 3 expander tampers viewing ARMED steady light all partitions operated by the keypad are armed blinking light some zones are armed 4 partition armed status viewing 5 alarm memory contents viewing 6 failure memory contents viewing see descriptions of functions CA 64 TESTS and EVEN HISTORY VIEWING NS e ai AGE N NI 17 18 19 0 212 23 4 25 27 28 2 30 31 32 gt 1 32 zones 1 32 or the first n Na o z expander bus 7 when pressed for 3 seconds a x message on currently detected failure is displayed 33 64 zones 33 64 or the second expand
75. ure 25 Description of user functions 41 SUMMARY The alarm control panel is one of components of an alarm system it works surrounded by many pieces of equipment and performance of each system component decides on the performance of the entire system Therefore we recommend testing the operation of the entire system and each system component on the regular basis It is a good practice to order periodic inspections from the system installer The installer should train system users on the following issues ways of signalling and types of alarms action procedures duringf various types of alarm correct work of the control panel with a monitoring station operation of modules which control the operation of the control panel operation of additional devices controlled by the control panel if such equipment is installed actions in case of failures in the system o o Pay particular attention to the number of messages transmitted to the monitoring station Large number of occurrences on which the monitoring station is informed by the control panel loads the telephone line excessively and it may make it difficult to send important information concerning the safety of object and people being inside Remember that operative alarm system is not the full protection against burglary attack or fire The system only reduces the risk of such occurences performing the functions of signalling and informing 42 APPENDIX C User
76. ust be set to the DTMF tone dialling If the code is not correct the control panel signals that with two long beeps Correct code is confirmed by four short and one long beeps When instead of sounds described above you hear a single short beep every three seconds the code is correct but you must wait because there are several messages about different alarms If you make a mistake when entering the code press any numeric key to supplement the code to four digits then the control panel signals erratic code and next enter the correct code Note The control panel analyses telephone signals in order to recognise whether the phone call is answered Therefore it may occur that you will hear the message after few seconds up to 4 seconds from picking the earphone This effect is not an error it results from phone call confirmation signal When you say halo to the earphone the message will be communicated immediately ANSWERING PHONE CALLS The control panel CA 64 is able to answer phone calls and communicate information on the system status Also you may call control functions with the use of telephone Each ordinary user may at the stage of user entering or edition be assigned with a telephone code do not mix this code with the code for confirmation of receipt of a telephone message on alarm The control panel recognises the system user with this code and passes an information on partition status armed alarms for part
77. wing partitions status viewing alarm memory viewing failure memory viewing current failure viewing switching on off gong signal in LCD keypad auxiliary alarm for example calling medical aid fire alarm attack alarm 4 tHXOONDOAARWNH Functions of keys from 1 to 8 are accessible from LCD keypad only and other functions may be accessible service setting from each keypad installed in the system LCD keypad partition keypad code lock The functions called this way provide information on all partitions operated with specific LCD keypads Also they are accessible via the User Menu see Description of User Functions Tests Event History Failures Change of Option however when called via the User Menu they provide the information on partitions accessible for the individual user who called that function only It is recommended that this way of calling functions be accessible in LCD keypads fully protected against access of unauthorised persons An attack alarm called by may be signalled externally in a similar way to an alarm of burglary type buzzers lights it also may be arranged not to activate any signalling and remain as a silent alarm PANIC service setting Also the installer may render accessible the function of quick arming of certain partitions so called QUICK ARM to be called by pressing two keys O and in sequence gt 04 quick arming o
78. y another user Manual test transmission the function generates the event which starts the procedure of message transmission to the monitoring station Monitoring station test 1A 1B 2A 2B the function makes possible to carry out the test transmission to the monitoring station to each accessible telephone number separately The test transmission is carried out with tracing the data transmission process at the same time The messages at the keypad display inform on current activity In practice the function is used by the installer when starting communication with a monitoring station Viewing masters the function is accessible for the administrator only It allows checking for which subsystems the administrators are created It allows to control the number of users who are able to give permission to access the system in the service mode Control panel version the function shows the current control panel software version number at the keypad screen No additional message is displayed at the time of exiting the function Description of user functions 39 select one of these functions press to exit code k P Tests Arming status graph Zone status t graph LCD keypad status0 graph service Expander status t graph service Supply voltage power service Zone test graph Manual test transmiss 1A station test 1B station test 2A station test 2B station test Viewing the m