1. Intellislot SNMP Web Card for use with the PowerSure GXT amp Nfinity UPS User Manual English INTRODUCTION cisccesisccipnccecteuchitesccecaet ates sivenstt ap cencerecsececasteees iedaeversetnenses 1 About this User Manual cccceeceeeceeeeeeeeneeeeeseeeeeeeeeseeeaeeeeeeeaaees 1 About the Quick Start Guide 00 eceeeeeeeeeeeeeeeeeeeeeeeeteeeeeeeeeeaaees 1 About the Text Formatting ccccceceseeeeeeeenneeeeeeeeneeeeeeeesaeeeeeeeaes 1 IWMKOGDUCUION tececcacdidesessawetecacisseadastaan eda ccadanaidaneeauseuaantadsrdeddanearvaadandisean 2 INSTALLATION eisceedssccceccescenuecnenessceckuti te steceeededeeuennutdacuectnace eevethedssoeeenved 5 installing the Card cccticcescceetelecetiec fe eeceee seen cendeeeeetdaeeueentiaaeetouas 5 Connecting the Card to the Network cceeceeceeeeeeeeeeeeenteeeeeeeeaas 5 Configuring the Card is iccccetndicatsdevisicisectrdiiiaecesdstageeesiadeeenelaeerans 6 SERVICE TERMINAL 9 sieictciscee ccssecessccesetscteessceeessecennisertessuseessseesewete re antes 7 Opening a Service Terminal Connection 0 cccceeeeeeeeeeeeeetteeeeeeeeee 7 Main Menu icscceiutiiek i eciaeatinee eevieriliier ene weenie 9 System Information MENU ccceeeeeeeeeeeeeeteeeeeeeeeeeeeteeeneeeeeseeaeees 10 Network Interface Menu cccccccceeesencceeeeeeneneeeeecenaneeeneenaneeeeeenees 11 SNMP Communication Menu 0 ecceeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeaeeees 13 Web S
2. Please select a key gt From the Web Server Menu you can enable disable the Web functionality of the card and edit the User Name and Password which regulate access to the Web control and configuration tabs Select option 1 to turn the entire Web Server ON or OFF NOTE If you select disabled the card will be totally inaccessible from the Web although it will continue to operate as an SNMP only agent Select option 2 to edit the User Name or Password that must both be entered correctly to control the UPS or to change configuration settings of the card from the Web The factory default User Name is Liebert and the Password is Liebert Because this is a well known username and password you should change it as soon as possible You can also change the User Name or Password from the Web From the service terminal you do not need to know the current User Name or Password to make a change NOTE When changing the Username of Password from the Ser vice Terminal it is possible to leave either field blank If you omit either the Username or Password field the Service Terminal will accept the input but it will set the response to the default of Lie bert If you have made a change you need to press Esc to return to the Main Menu and then press x to exit and save changes 16 Firmware Updates Menu Selecting Option 5 from the Main Menu opens the Firmware Updates Menu Firmware Updates Menu 1 In
3. Folders Within each tab you will see a different list of folders on left pane of your screen Here display control and configuration information is grouped logically If for example you click the Input folder under the monitor tab you will see only information about the UPS input power 20 Connected Device Information Clicking between the monitor contol configure and support tabs gives you access to folder lists on the bottom of the left pane Although the folder list changes depending on the tab selected the top portion of the left pane remains constant In the top of the left pane summary net work and connected UPS status is always presented Liebert OpenComms Network Interface Card Microsoft Internet Explorer Ele Edt View Favorites I e E Beck Forward Stop Refresh 126 GXT700MT 120 Connected Device Status Load Protected Normal Operation Charge 100 Time Remaining 385 min Last updated Friday January 26 2001 03 07 09pm B mena The IP address of the card and the Liebert UPS model type is presented under Connected Device In this example the ntellislot SNMP Web Card is installed in a UPStation GXT 700VA UPS and has been assigned the IP address 126 4 20 92 The current operating state of the UPS is presented under Connected Device Status along with the most serious UPS alarm if one is present For our example above the UPS is operating normally with good util
4. Web Open a web connection to the ntellislot SNMP Web Card Click on the Configure tab In order for MultiLink to monitor the card the network address information of the machine on which MultiLink is installed needs to be added to both the Access and Traps folders 35 As an example you have installed MultiLink on a PC and you will monitor across the network the ntellislot SNMP Web Card you are now installing Your PC has the IP address of 126 4 1 1 Select option 2 from the SNMP Communications Menu and add 126 4 1 1 with the community string LiebertEM Select option 3 from the SNMP Communications Menu and add 126 4 1 1 with the community string LiebertEM 36 Nfinity Support The Intellislot SNMP Web Card presents additional information on the Power Flow folder when installed in a Nfinity Z Liebert OpenComms Network Interface Card Microsoft Internet Explorer Ele Edt View Favorites Tools Help e gt 08 Ala a GiB 3J M Back Fowsd Stop Rekesh Home Search Favorites History Mail Pint Edi Address hitp 7126 4 20 92 oT Power Flow 16000 VA FRAME 16000 VAFRAME CONTROL MODULES 2 INSTALLED CONTROL MODULES 0 FAILED 2 INSTALLED 1 REDUNDANT O FAILED 1 REDUNDANT Volts 242V POWER MODULES POWER MODULES 4 INSTALLED Sai 4 INSTALLED mo Input 0 FAILED 3 REDUNDANT B 3 REDUNDANT BATTERY MODULES 4 INSTALLED OFAILED Pe Keren BATTERY M
5. always located online and you should consult the Web if you feel you have an older copy About the Quick Start Guide In the Appendices you will find a copy of the Quick Start Guide The Quick Start Guide ships in the box with the Intellislot SNMP Web Card and provides the most important information you need to install and con figure of the card It included with this manual for your reference About the Text Formatting Whenever a Liebert product is referred to the product name appears in Italics Text from Service Terminal screens is shown using Courier Text representing tabs and folders on the Web interface are show in bold Text that you need to enter from the keyboard is also shown using Cou rier and the required text is in quotations Introduction The ntellislot SNMP Web Card delivers SNMP Simple Network Manage ment Protocol and Web support to the UPS in which it is installed The card is designed for use in a Liebert UPS with an Intellislot bay This includes the PowerSure Interactive UPStation GXT UPStation GXT2U and Nfinity The Intellislot SNMP Web Card requires an Ethernet network connection and supports both 10Mbit and 100Mbit communication speeds and either half or full duplex The I ntellislot SNMP Web Card enables in band communication via the Web from computers running web browser software The Intellislot SNMP Web Card enables in band communication with net work management systems NMS
6. is shown below Z Liebert OpenComms Network Interface Card Microsoft Internet Explorer Ble Edt View Favorites Tools Help eae 8 Ala 43 2 3 w Back Fomara Stop Refresh Home Search Favorites Histoy Mal Print Edt Discuss ees E menssa monitor control configike Configuration Categories gs ji 3 igeemsighout saving and rebooting will result in a Configuration Categories E Data Room UPS Device Info and description Factory Defaults Configuration Categoriest Network router of the device SNMP jicate with other network hosts via TCP IP Acces Traps Users a popular Standards based networking ee as endors for management of devices It is Web MP Trap targets for significant device cess to the protected configuration and ii Speci the automatic client pull refresh interval for dynamic pages TT D nene Device Info Clicking on the Device Info folder allows you to edit the Name Contact Location and Description fields Factory Defaults Clicking on the Factory Defaults folder allows you to reset the card to the factory settings Network Clicking on the Network folder allows you edit the IP address Subnet and Default Route of the card You are also able to change the boot mode setting of Static IP DHCP or BootP 29 SNMP Clicking on the SNMP folder allows you to enable authentication traps Clicking on the Access or Traps folder allows you to config
7. must use the Service Terminal You access the Web Interface of the ntellislot SNMP Web Card by open ing a direct web browser The card utilizes functionality of Microsoft Internet Explorer 5 0 or higher Whenever possible you should use the latest copy of IE 1 Open Internet Explorer 2 Enter the IP address or hostname of the card in the address line of your browser The first page you will see every time you open a new Web connection to the card is the Power Flow folder in the monitor tab After your browser connects you will see a screen very similar to below Liebert OpenComms Network Interface Card Microsoft Internet Explorer Ble Edt View Favorites Tools Help ala ad AIEN each Hitoy Mal Favorites 9 I Back Foryerd Stop Refresh Home Address htp 7126 4 20 92 monitor control Power Flow BYPASS Volts 121V OUTPUT Vots 121v Amps 14 BATTERY Volts 28V Charge 100 Time Remaining 385 min Last updated Friday January 26 2001 03 07 09pm OT Emea 19 You will notice that information on the Web page is grouped in Tabs and Folders The card organizes similar information together in folders and similar functions in tabs Tabs Across the top of the screen are four tabs monitor con trol configure and support As the tab names suggest differ ent information is presented and different operations are available to you under each tab
8. to assign an administrative contact Selecting option 3 to assign location information Selecting option 4 to assign a description The Name field can be up to 255 characters in length The Contact Location and Description fields can be up to 64 characters in length If you have made a change you need to press Esc to return to the Main Menu and then press x to exit and save changes 10 Network Interface Menu Selecting Option 2 from the Main Menu opens the Network Interface Menu Network Interface Menu 1 Speed Duplex Auto Boot mode DHCP IP Address 126 4 1 19 Netmask 29929962900 lt ESC gt Cancel menu level Please select a key gt From the Network Interface Menu you can configure the Network settings of the card Select option 1 to change the communication speed of the card or the duplex setting Please select a key gt 1 Valid Selections 1 Auto 2 10Mbs Half Duplex 3 10Mbs Full Duplex 4 100Mbs Half Duplex 5 100Mbs Full Duplex Select Speed and Duplex Setting The Speed Duplex default setting is Auto and the card attempts to negoti ate the optimal setting for your network environment You can select a fixed setting for either 10Mbit or 100Mbit speed at either full or half duplex 11 Select option 2 to change Boot mode settings of the card Valid Selections 1 Static 2 BootP 32 DHCP Select Boot Mode Your Boot mode setting options are Static BootP and
9. DHCP The card ships from the factory with DHCP service enabled DHCP allows the card to obtain an address dynamically from a DHCP server on your network The card also supports BootP dynamic configuration If you are using DHCP or BootP you may find want to configure your DHCP or BootP server with the MAC Address of the card so that the server always assigns the card a specific address The MAC Address is printed on a sticker affixed to the top of the card To assign the card a fixed IP address you need to change the Boot mode to Static and then provide an IP Address Netmask and Default Route Network Interface Menu 1 Speed Duplex Auto 2 Boot mode Static 3 IP Address 126 4 1 102 4 Netmask 2552959629560 5 Default Gateway 126 4 1 1 If you have made a change you need to press Esc to return to the Main Menu and then press x to exit and save changes 12 SNMP Communication Menu Selecting Option 3 from the Main Menu opens the SNMP Communica tions Menu Liebert Network Interface Card SNMP Communications Menu 1 Authentication Traps no 2 Display Modify Communities 3 Display Modify Trap Communities lt ESC gt Cancel menu level Please select a key gt From the SNMP Communications Menu you can configure the SNMP set tings and behavior of the card Select option 1 to turn authentication traps on or off Enter y to enable authentication traps Enter n to disable authentication traps
10. January 26 2001 03 07 09pm m From the monitor tab you are able to view the parametric data of the UPS The Power Flow folder provides a graphical representation of the current state of the UPS along with useful information about input output and battery voltages as well as battery runtime information The Alarm folder provides a list or any present UPS alarms 26 Clicking on the Battery Output Input Bypass not supported in Power Sure Interactive or Internals folder replaces the summary data pre sented on the graphical power flow pane with a tabular view of the complete list of data points reported by the UPS Clicking on the Input folder presents a screen similar to Z Liebert OpenComms Network Interface Card Microsoft Internet Explorer Bile Edit View Favorites Toole Help oe o6 Ala Gi alp 4 m RE Back fowsd Stop Rehesh Home Search Favorites History Address hitp 126 4 20 92 x Go monitor control configure support Parameter Units Input voltage Input frequency Hz Information Input voltage maximum Input voltage minimum Nominal input current Nominal input frequency Nominal Static Bypass Switch voltage Nominal input voltage Condition Bad input frequency Power factor correction on Input overvoltage Utility failed Last updated Friday January 26 2001 04 15 22pm In the tabular view d
11. ODULES 4 INSTALLED OFAILED 30 27pm L T ep internet Because the Nfinity is a redundant and scalable UPS it is important to know exactly what is installed in its bays The additional Power Flow table shows the maximum VA rating of the Nfinity frame along with infor mation about installed Control Power and Battery modules You will also find Nfinity specific parameters used for SNMP alarming and status in the Liebert Global Products MIB 37 The Company Behind the Products With over a million installations around the globe Liebert is the world leader in computer protection systems Since it s founding in 1965 Liebert has developed a complete range of supportand protection systems for sensitive electronics Environmental systems close control air conditioning from 1 5 to 60 tons Power conditioning and UPS with power ranges from 250 VA to more than 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control from systems of any size or location on site or remote Service and support through more than 100 service centers around the world and a 24 7 Customer Response Center While every precaution has been taken to ensure accuracy and completeness of this lit erature Liebert Corporation assumes no responsiblity and disclaims all liability for dam ages resulting from use of this information or for any
12. Select option 2 to edit the list of devices you want to have access to the card via SNMP Display Modify Communities Menu 1 126 4 1 100 write MyCommunity lt ESC gt Cancel menu level lt a gt dd lt d gt elete lt e gt dit Complex lines allowed e g lt a 198 1 1 1 write public gt gt The options a q and e allow you to manage your list of network devices with access to the card These options can be used as a com 13 plex instruction to add a single device specify read write access rights and designate the Community String For example entering a 126 4 1 200 read NewCommunity adds device 126 4 1 200 to the community list The menu will update Display Modify Communities Menu 1 126 4 1 100 write MyCommunity 2 126 4 1 200 read NewCommunity lt ESC gt Cancel menu level lt a gt dd lt d gt elete lt e gt dit As you are adding communities you need to consider access rights Notice above that 126 4 1 100 has write access when the device passes the correct Community String of MyCommunity This means that this net work device has both read and write access to the card whereas 126 4 1 200 has only the ability to read information when providing the correct Community String Devices with write access can control the UPS and reconfigure settings of the card In order for a device you have added to the Communities Menu to also receive notification from the card via SNMP Traps for UPS alarms and c
13. al configuration cable to the DB 9M serial port on the ntellislot SNMP Web Card 3 Connect the other end of the blue serial configuration cable to a ter minal or a PC running terminal emulator software like HyperTermi nal or ProoCcomm NOTE If you are using a laptop or PC without any con nected serial devices your active serial port is most likely COM1 If you have the correct cable and are unable to open a connection please confirm that you do not have a COM port conflict 4 Use the following communication settings BAUD RATE 9600 DATA BITS 8 PARITY NONE STOP BITS 1 FLOW CONTROL NONE 5 Press Enter to see the Main Menu If you do not see the Main Menu press Enter again several times If the Main Menu fails to appear confirm that the blue configuration cable is installed properly that your PC or terminal COM port is active and that you are using the correct communication settings If after verifying the cable and your communication settings are correct you still do not see the Main Menu reinstall the card in the Intellislot bay NOTE The card is powered by the UPS If the UPS is ON the card will operate automatically If you have the cable connected while inserting the card you will see initialization text scroll on your screen If the card has already been powered you will not see this information Main Menu From the Main Menu screen you will find configuration information func tional
14. ata like input voltage that changes over time is grouped as a Parameter Values which are known to the UPS like nom inal input frequency are reported in Information Finally condition parameters like utility failed are together in a table labeled Condition The list of data in each of these sections and folders varies across UPS product lines and sizes and will change depending on the UPS in which you have installed the card 27 Control Tab When you select the control tab you are presented with Connected Device and Connected Device Status on the top of the left pane The folder list is at the bottom of the pane under Control Operations As detailed in the Web Security section a Username and Password pro tect the folders in the control tab From the control tab you can do things like turn the UPS output ON or OFF Each folder represents a different control behavior and this list will vary across UPS product lines and sizes 28 Configure Tab When you select the configure tab you are presented with Connected Device and Connected Device Status on the top of the left pane The folder list is at the bottom of the pane under Configuration Categories As detailed in the Web Security section a Username and Password pro tect the folders in the configure tab When you click on a folder under Configuration Categories you will be able to edit network and device settings including SNMP community lists The folder list
15. er DHCP or BootP you will receive the following warning The card has rebooted to an unknown dynamic address Please consult a network administrator for the address You may know the address the card will be assigned by your BootP or DHCP server In this case simply enter that address into your web browser and reconnect Logically the card has no way of knowing what the new address will be if you change from Static to BootP or DHCP Although this feature is made available to you from the Web you should use caution when making the change 25 Monitor Tab When you select the monitor tab you are presented with Connected Device and Connected Device Status on the top of the left pane The folder list is at the bottom of the pane under Device Information The first page you will see every time you open a new Web connection to the card is the Power Flow folder in the monitor tab After your browser connects you will see a screen very similar to below Liebert OpenComms Network Interface Card Microsoft Internet Explorer Bile Edit View Favorites Tools Help t 2 92 28 Ala a lela a Back Foward Stop Refresh Home Search Address J hitp 126 4 20 927 Favorites History Mail Print Ear monitor control Jf configure Power Flow BYPASS vots 121V OUTPUT Vots 121V 1A Output a Input BATTERY E Volts 28V Charge 100 Time Remaining 385 min Last updated Friday
16. errors or omissions 2001 Liebert Corporation All rights reserved throughout the world Spec ifications subject to change without notice Liebert and the Liebert logo are registered trademarks of Liebert Corporation All names refered to are trademarks or registered trad marks of their repective owners SL 52610 1 01 Rev 0
17. erver Menu cescceciercncnnecannnnni nsa aa 16 Firmware Updates Menu ceceeeeeeeeeceeceeeeeeeeeeeeeeseetensansaeeaeees 17 Factory Settings Menu lt 2 cis452 ces diene eve dcctaaees dtcaeeedeinseeeediiaiadeeeae 18 WEB wcccscsssceesstectesecevecteeacnectevenccenvceecezeeceesecneaned sce ecdeeevendsssecereaaneeenete vsed 19 Opening a Web Connection cceeeceeeeneeetecneeeeee tennessee tnneeeerees 19 Connected Device Information 0 c cccccceeeeeeeeeneeeeeteeneeeeeeeeaeees 21 SOTUN eieae irena EEEn E TEET EE EEEE AE E 22 Before clicking Save and Reboot 00 ee ceeeeceeeeeeeeeeeeeeeeeeeteeeeeeeaaes 23 After clicking Save and Reboot eceeeeeeeeeeeeeeeeeenneeeeeeenaeeeeeseaas 24 Monitor Tab siecia ddan a aaa 26 Control Tab oo eececcccecceeeeeeceeeneceeceeeeeeeeeeeeeeeseceaeaaeaeeeeeeeeseeteeeensinaeees 28 Configure Tab ci chieiccteieraeieicn duet Sassi aie 29 S10 0 ole a ail k one ee 32 SNMP uicocdbetecenchsdenvacedevede tees devetstecidinca te ecctedeseysstisbiaeeedsbectiededeSeelline ntti 33 APPENDICES i scsscccctceeceseceieicives scieccieneveesdinteneciteseaeeesinesesacdreeeiee eaaa 35 Multi Link Support assassini a a aE 35 Nfinity Support c ccceccccceceeeeceeeeeeeeeeeecaecaeeeeeeeeeeteeeecsesnieeeees 37 About this User Manual Welcome to the User Manual for the I ntellislot SNMP Web Card This manual is available from Liebert s web site at www liebert com The most recent version is
18. ext will remain on the screen for several seconds When the card serves this text to your web browser it also passes instructions for the browser to wait and then attempt to refresh If however this text persists you may need to manually click the browser s Refresh button As the card continues the reboot process you may see the following text displayed Discovering connected device Last updated Monday This text is shown after the card has successfully connected to the net work and is operating normally but has yet to complete opening a con nection to the UPS As the card reboots your active page may remain blank for a brief period of time your web browser may give an unable to connect warning or it may continue to display one of the messages above Due to some timing issues with networks and static nature of browsers you may need to click the browser s Refresh button Your refresh will take you to the Power Flow folder in the monitor tab NOTE If the Discovering connected device text persists even after clicking the browser s Refresh button and you are never presented a graphical UPS page the card is receiving power and 24 operating properly but it is having problems communicating with the UPS When you make changes to the network address setting of the card your web browser will be redirected to the new address and the browser will open a new window If you change from a Static IP address to eith
19. itiate XMODEM session lt ESC gt Cancel menu level Please select a key gt From the Firmware Updates Menu you can reload the firmware of the card Please consult the instructions you downloaded or received with you new firmware version 17 Factory Settings Menu Selecting Option 6 from the Main Menu opens Factory Settings Menu Factory Settings Menu 1 Reset to Factory Defaults Manufacture Date MAC Address 00 Serial Number 415981G101 lt ESC gt Cancel menu level Please select a key gt OCT 27 2000 00 68 16 00 03 D20000CT270003 The Factory Settings Menu displays information you may be asked by Liebert Technical Applications Support and is you can access the MAC address on demand have the option of resetting all the settings of th the only electronic place From the menu you also e card the factory default Selecting 1 will likely cause the card to be inaccessible from the network so its use should be applied with caution If you have made a change you need to press 1 Esc to return to the Main Menu and then press x to exit and save changes 18 Opening a Web Connection This section explains the Web interface in detail From the Web you can monitor and control the UPS in which the card is installed You can also configure many settings of the card NOTE To specify that the card communicates at either 10Mbit or 100Mbit instead of it trying to auto negotiate you
20. ity power 21 Security By opening a connection to the ntellislot SNMP Web Card you are able to do three things You can monitor the UPS You can also configure or reconfigure network settings and access rights of the card And finally you can control the UPS in which it is installed The card allows any user with access to the network segment on which it is installed to monitor the UPS This means anyone on the segment can view the entire contents of the monitor and support tabs The card restricts access to the folders in the control and configure tabs When a user clicks on a folder the are prompted to for a User Name and Password yo Please type your user name and password Ste 1264 110 Resm Raai User Name j ebeit Password I Save this password in pout password list Lo o The factory default User Name is Liebert and the Password is Liebert Because this is a well known username and password you should change it as soon as possible If you have not made this change from the Service Terminal you can do so from the Web 22 Before clicking Save and Reboot Just as you discovered when using the Service Terminal every time you make a configuration change the card must reboot for that change to take effect Making changes from the Web is the same As you navigate between the card s web pages you will notice that configuration screens include buttons with text Save and Reboot As an example the scree
21. ly grouped Liebert Network Interface Card Main Menu 1 System Information 2 Network Interface 3 SNMP Communications 4 Web Server 5 Firmware Updates 6 Factory Settings and abort changes and save Please select a key gt Changes you make using the Service Terminal will only take effect after the card reboots Accordingly you always need to return to the Main Menu screen after making any change s and then select either option q or x If you select option q your changes will be aborted and the card will retain its previous settings If you select option x the card will reboot and restart with your changes System Information Menu Selecting option 1 from the Main Menu opens the System Information Menu Liebert Network Interface Card System Information Menu 1 Name Data Room UPS 2 Contact Network Services x100 3 Location Building 2 Floor 4 4 Description Supporting Main Server lt ESC gt Cancel menu level Please select a key gt The System Information Menu contains four user defined data fields The Service Terminal will report Uninitialized where you have not entered personalized data The System Information Menu allows you to enter useful location and contact information The data in these fields is available via SNMP and is presented in the support tab on the Web page A typical configuration includes Selecting option 1 to assign a name to the UPS Selecting option 2
22. n shot below shows the edit fields available under the configure tab when you select the Network folder Bak Fod Siop piah Home avotites Address 227 hitp 7 126 4 20 27 224 3 221 Boot Mode Static BootP DHCP janageable segments j Ip Address fi 26 4 20 92 idministrator Subnet Mask 255 255 255 0 p D 255 separated with a Default Gateway 126 4 20 1 orks or subnets Save and Reboot Reset idministrator 255 separated with a Boot Mode Static BootP DHCP Ip Address fizeazo92 Subnet Mask 255 255 2550 Default Gateway EZEN Save and Reboot Reset When you click any of the web page Save and Reboot buttons the card saves any changes you have made and then restarts During this time the card is unavailable on the network When this process begins your web browser may be instructed to open a new page 23 After clicking Save and Reboot Anytime you press a Save and Reboot button on any of the card s web pages the card will reinitialize During this time the card is unavailable on the network As the card reboots it first begins communicating on the network and then establishes communications with the UPS in which it is installed The card will present to you some helpful information during the period of time that it is restarting You will usually see the following text after you click a Save and Reboot button Redirecting due to user configuration change This t
23. ondition changed you also need to add the device to the Trap Communities Menu See below for details Select option 3 to edit the list of devices you want to receive traps from the card via SNMP Display Modify Trap Communities Menu 1 126 4 1 100 MyCommunity lt ESC gt Cancel menu level lt a gt dd lt d gt elete lt e gt dit Complex lines allowed e g lt a 198 1 1 1 public gt gt The options a da and e allow you to manage you list of network devices that will receive SNMP Traps from the card These options can 14 be used as a complex instruction to add a single device and designate the Community String For example entering a 126 4 1 200 NewCommunity adds device 126 4 1 200 to the trap community list The menu will update Display Modify Trap Communities Menu 1 126 4 1 100 MyCommunity 2 126 4 1 200 NewCommunity lt ESC gt Cancel menu level lt a gt dd lt d gt elete lt e gt dit It is important to remember that you will often need to add a network device to both the Communities Menu and the Trap Communities Menu for your SNMP implementation to work as designed If you have made a change you need to press Esc to return to the Main Menu and then press x to exit and save changes 15 Web Server Menu Selecting Option 4 from the Main Menu opens the Web Server Menu Web Server Menu 1 Web Server enabled 2 Change Username Password lt ESC gt Cancel menu level
24. tification from the card via SNMP Traps for UPS alarms and condition changeds you also need to add the device to the Traps folder 30 Users Clicking on the Users folder allows you to edit the Username or Password that must both be entered correctly to control the UPS or change configu ration settings of the card from the Web The factory default User Name is Liebert and the Password is Liebert Because this is a well known username and password you should change it as soon as possible You can also change the Username or Password from the Service Terminal From the Web you need to know the current Username and Password to make a change Web Clicking on the Web folder allows you to modify the Web browser refresh rate Due to the static nature of the Web the card instructs your Web browser to refresh many areas of the card s web page at a specific inter val 31 Support Tab When you select the support tab you are presented with Connected Device and Connected Device Status on the top of the left pane A single device list is at the bottom of the pane under Support The support tab displays the Name Location and Description fields as well as relevant contact information for Liebert Technical Applications Support team 32 The ntellislot SNMP Web Card utilizes a SNMPv1 agent and is MIB II compliant The card supports the open standard UPS MIB RFC1628 and augments needed functionality in the proprietar
25. uplex The card ships from the factory in an auto sensing mode In this mode the card works to negotiate the optimal setting for your network environment To turn off the auto sensing mode and force the card s communication speed or duplex setting you will need to open a Service Terminal connection to the card Please refer to the Service Ter minal section Configuring the Card The card ships from the factory with DHCP service enabled The MAC address is located on the outside of the box and is also printed on a sticker affixed to the top of card To give the card a static IP address you will need to open a Service Ter minal connection to the card Please see the following section for more on the Service Terminal ee Opening a Service Terminal Connection This section covers the Service Terminal in detail From the Service Ter minal you can configure all settings of the card NOTE You can also configure many of the settings discussed in this section from the Web To specify that the card communicate at either 10Mbit or 100Mbit instead of it trying to auto negotiate you must use the Service Terminal You access the Service Terminal by opening a direct serial connection to the ntellislot SNMP Web Card 1 Locate the blue serial configuration cable that shipped with the card NOTE If you have misplaced the cable provided you can use a null modem cable with a DB 9F connector at both ends 2 Connect one end of the blue seri
26. ure the devices you want to have access to the card via SNMP and devices you want to receive traps from the card An example configuration in the Access folder is shown below Liebert OpenComms Network Interface Card Microsoft Internet Explorer Eie Edt View Favorites Tools Help eon e B a w Back fod Stop Refresh Home Search Favorites History Mai Address hup 7126 4 20 92 monitor vm me control vb Parameter Description IP Address Access Community 126 4 1 100 read write MyCommunity 126 41 200 read write NewCommunity ie read write Save and Reboot Reset Entry IP Address Access 1 ao C read wite 2 feaz read C wite 3 e read write Community MyCommunity Clear NewCommunity Clear Clear Ei _ _ nera 7 Copyright Liebert Corporation 2000 As you are adding communities you need to consider access rights Notice above that 126 4 1 100 has write access when the device passes the correct Community String of MyCommunity This means that this net work device has both read and write access to the card whereas 126 4 1 200 has only the ability to read information when providing the correct Community String Devices with write access can control the UPS and reconfigure settings of the card In order for a device you have added to the Access folder to also receive no
27. via SNMP The ntellislot SNMP Web Card integrates with Liebert s MultiLink soft ware to provide notification for unattended graceful operating system shutdown of PCs servers and workstations MultiLink is available for most operating systems For more information on MultiLink and down loadable version of MultiLink software please visit www liebert com Installing the Card The ntellislot SNMP Web Card is hot swappable and user serviceable You do not need to turn off the UPS disconnect any loads or restart the UPS to install or remove the card CAUTION The Intellislot Bay is located in close proximity to the UPS output and the UPS electrical receptacles Whenever pos sible you should turn the UPS OFF when installing the card To install the card 1 Locate the Intellislot bay on the back of the UPS For Nfinity use the Intellislot labeled COM1 2 Remove the plastic Intellislot cover and save the screws for Step 4 3 Insert the Intellislot SNMP Web Card into the Intellislot bay 4 Secure the card with the screws you removed in Step 2 NOTE The card is powered by the UPS during both normal and on battery operation If the UPS is ON the card will operate nor mally after a brief boot up period Connecting the Card to the Network To connect the card to the network simply plug an Ethernet cable to the RJ 45 connector on the card The card supports 10Mbit and 100Mbit communication speeds at either half or full d
28. y Liebert Global Prod ucts MIB A copy of the Liebert Global Products MIB on CD is included in the box with the card 33 MultiLink Support The most frequently asked question about configuring MultiLink to moni tor a SNMP device like the ntellislot SNMP Web Card across the net work is what community string do use NOTE Use the community string LiebertEm for MultiLink Configuring for MultiLink support from the Service Terminal From the Main Menu select option 3 for SNMP Communications Menu In order for MultiLink to monitor the card the network address information of the machine on which MultiLink is installed needs to be added to both the Display Modify Communities and the Display Modify Trap Communi ties As an example you have installed MultiLink on a PC and you will monitor across the network the Intellislot SNMP Web Card you are now installing Your PC has the IP address of 126 4 1 1 Select option 2 from the SNMP Communications Menu and add 126 4 1 1 with the community string LiebertEM Select option 3 from the SNMP Communications Menu and add 126 4 1 1 with the community string LiebertEM If you have made a change you need to press Esc to return to the Main Menu and then press x to exit and save changes Adding to both the Communities list and the Trap Communities list is nec essary for MultiLink to work properly Configuring for MultiLink support from the
Download Pdf Manuals
Related Search
Related Contents
Volkswagen - Car-Tek Workshop Practicum PCX用 ヘッドライトコントローラー 取扱説明書 ficha de asignaturas de humanidades para guía docente Télécharger la notice d`utilisation iikoOffice user guide StarTech.com Standalone 2.5 / 3.5” SATA Hard Drive Duplicator w/ Multi HDD / SSD Image Backup Library Instructions pas-à EVGA e-GeForce 8800 GTX KO ACS3 NVIDIA GeForce 8800 GTX Copyright © All rights reserved.