Home
SDC-TS7 7” Sedona Touchscreen Installation Guide
Contents
1. OUTSIDE 120 00 EXTRACT AIR 23 7 C EZB A Change Password Manage Account le Signout a HTG 18 0 CLG 18 0 o SUPPLY AIR 23 77 SDC TS7 7 Sedona Touchscreen Installation Guide SyxthSense Ltd 3 Topsham Units Dart Business Park Topsham Exeter Devon EX3 United Kingdom Tel 0844 840 3100 Fax 0844 840 3200 S YXTHSENSE WWW Syxthsense com SYXTHSENSE Copyright Notice This document has been prepared by SyxthSense Limited using i its own proprietary information and ii proprietary information owned and controlled by other third parties for which SyxthSense Limited has a right to use The contents are copyrighted and must not be communicated in whole or in part to any other party without the prior written approval of SyxthSense Limited The following notice applies to this document and shall be reproduced on any permitted copies 2014 SyxthSense Limited All rights reserved Any request for further information concerning this document should be addressed to SyxthSense Limited 3 Topsham Units Dart Business Park Topsham Exeter United Kingdom Online Store www syxthsense com Copyright 2013 SyxthSense Ltd Ver 0 2 Enquiries T 0844 840 3100 F 0844 840 3200 SDC AN14 easyioKits User Manual 2 SYXTHSENSE CONTENTS MUN TOON yu 4 2 DEV
2. select sdcard directory Install from the USB stick AutoWeb folder the Autoweb application Two AutoWeb versions are available 1 03 can be used in Android 4 1 without Status Bar with Built In Browser V1 03 browser hides the URL bar 1 02S uses Google browser with status bar which can be hidden from the Android Settings Apps Browser menu Google browser provides Zoom facility 3 Uninstalling AutoWeb Changing the Controller IP Address 3 1 1 1 Uninstalling Autoweb The AutoWeb application can be uninstalled under Settings Apps And selecting AutoWeb 3 1 1 2 Resetting Autoweb Controller Address The controller IP address stored in the AutoWeb application can be deleted under Settings Apps And selecting AutoWeb and selecting Clear Data Online Store www syxthsense com Copyright 2013 SyxthSense Ltd Ver 0 2 Enquiries T 0844 840 3100 F 0844 840 3200 50 14 easyioKits User Manual 6 SYXTHSENSE 4 Updating SDC TS7 Firmware By selecting the Autoweb 1 03 as the default boot up option it may not be no longer possible to access the Android settings on the SDC TS7 For example if the SDC TS7 IP address settings are not correctly configured the display will not connect to the host device as the IP address set up is not correct The only way is to restore the factory defaults This is done by plugging in a Micro SD card to the side of the SDC TS7 and upgrading the Android firmware First of a
3. ICE INSTALLATION amp BOOT UP 4 1 SETTING AUTOWEB AUTOMATIC WEB BROWSER 0 0 00 0 0 0 he enne 5 2 SETTING ETHERNET DEVICE ADDRESS 0 000000000000000000 5 3 UPDATHNGAUTOWV EBD 6 3 UNINSTALLING AUTOWEB CHANGING THE CONTROLLER IP 5 6 4 UPDATING SDC TS7 FIRMWARE 7 s DOCUNIENFCONIROL uu u a u sas 8 Online Store www syxthsense com Copyright 2013 SyxthSense Ltd Ver 0 2 Enquiries T 0844 840 3100 F 0844 840 3200 50 14 easyioKits User Manual 3 if 4 7 Y d K 1 1 f i A 2 S YXTHSENSE 1 Installation The SyxthSense SDC TS7 is 7 Tablet PC used with SDC xG graphics series controllers or any other device that uses web browser technology The SDC TS7 has Android operating system and connects to the SDC xG controllers and other devices using the Ethernet network The SDC TS7 has auto boot operation that boots the tablet immediately once the power is applied to it Furthermore the device comes with AutoWeb application that launches automatically on boot up the web b
4. ll download the new SDC TS7 firmware from www syxthsense com support section The unzip the firmware file to MicroSD card as shown below gg Data Volume CF MD F a 5D mini MMC Rs G Firmmwarelnstall k Firmwarelnstall System Volume Information wmt scriptcmd System Volume Information Download the new Android firmware from www syxthsense com Support section Copy the files to the MicroSD Card min 1GB unzipped as above Power down SDC TS7 Insert the MicroSD card to the SDC TS7 SD card holder is on the right hand side when you lift up the screen Power Up the SDC TS7 the new OS installation will automatically start Follow the on screen instructions Now re install the AutoWeb following the instructions from the Section 3 mI NOTE Do not power dwon the SDC TS7 when the firmware is being updated This may damage the unit permanently Online Store www syxthsense com Copyright 2013 SyxthSense Ltd Ver 0 2 Enquiries T 0844 840 3100 F 0844 840 3200 50 14 easyioKits User Manual 7 Y SYXTHSENSE 5 Document Control Version Date Change History 0 1 29 Apr 2014 Original Release 0 2 09 Jun 2014 Upgrading the Firmware Details Added Online Store www syxthsense com Copyright 2013 SyxthSense Ltd Ver 0 2 Enquiries T 0844 840 3100 F 0844 840 3200 SDC AN14 easyioKits User Manual 8 6555 SYXTHSENSE 095 SYXTHSENSE SyxthSense Limited 3 Topsham Units Dart B
5. oWeb There is also Tickbox for Use by default for this application Initially for the IP address setup select Android 4 0 and follow Setting Ethernet Device Address section how to set up the IP address By selecting the AutoWeb option a field is displayed to enter the controller IP address e g 192 168 10 11 default IP address for the SDC xG controllers After entering the IP address click Save and this is now stored in the AutoWeb settings the setting can be deleted see section Changing the Controller IP Address Now when the Autoweb is selected at the bootup and the AutoWeb option is selected the Tablet PC automatically opens Web browser link to the controller You can also get to the boot up screen by pressing Android toolbar Up icon WARNING When the option Use by default for this application is ticked the selection between Android 4 0 and AutoWeb is no longer displayed If AutoWeb is selected the only way to change settings after ticking the box is by going to the settings via the bottom toolbar and the clock icon As default with SDC TS7 the AutoWeb 1 03 is installed that removes all the toolbars With this browser it is necessary to program the host controller e g SDC xG web graphics to fit inside the Android web page To facilitate the CPT tool has under graphics library an object showing the frame size Note If desired it is possible to uninstall the Autoweb 1 03 and install AutoWeb 1 02S that uses Google b
6. rowser This browser shows the controller URL which can be set to auto hide from Android Apps Browser The Google browser can zoom out the web page to fit the graphics page on the SDC TS7 screen See section Updating AutoWeb for details 2 Setting Ethernet Device Address Before it is possible to connect the SDC TS7 to the host controller it is necessary to set up the SDC TS7 IP address To do this select Android OS 1 Goto Settings 2 Goto Ethernet 3 Select Use Static IP for the static IP addressing 4 Set IP Address Gateway Netmask fields E g if the default IP settings of the SDC xG controller are IP Address 192 168 10 11 Subnet 255 255 255 0 Then the SDC TS7 display IP address is to be set as IP Address 192 168 10 x where x is between 1 255 but not 11 l e 192 168 10 21 Subnet 255 255 255 0 Online Store www syxthsense com Copyright 2013 SyxthSense Ltd Ver 0 2 Enquiries T 0844 840 3100 F 0844 840 3200 SDC AN14 easyioKits User Manual 5 3 SYXTHSENSE Updating AutoWeb The AutoWeb is the application that automatically boots the web page when the Table PC is powered up Using the Autoweb the access to the Android OS is restricted and the Tablet PC becomes dedicated front end Plug in microSD card stick with the apk installation files Click File Browser Application if the SD card content is not shown automatically Normally the content of the SD card is shown automatically If not
7. rowser that is used to navigate the host controller system graphics The SDC TS7 and also WiFi connectivity that allows the Tablet to be used as the WiFi access point In this way it is possible to use the SDC TS7 as the access point to navigate the graphics of the host system using mobile phones and other WiFi devices The SDC TS7 are powered from 9 27VDC which makes them suitable for panel installations and come with the panel mounting brackets 2 Device Installation amp Boot Up Cut on the panel a square cut out cut out W204x150mm Push the SDC TS through the cut out Clip the display open up and used the mounting brackets to clamp the display on the panel door SDC TS7 DIMENSIONS PANEL DOOR MOUNTING BRACKET Ww L us A Dr 142 mm 165 mm 2mm 200 mm 217 mm Once the DC power has been applied to the SDC TS7 the display boots up the Android OS Once the boot has been completed the initial start up screen is displayed asking whether the Android operating system is used or if the AutoWeb application is used Online Store www syxthsense com Copyright 2013 SyxthSense Ltd Ver 0 2 Enquiries T 0844 840 3100 F 0844 840 3200 50 14 easyioKits User Manual 4 SYXTHSENSE 1 Setting AutoWeb Automatic Web Browser Boot When the AutoWeb application has been installed on boot up the Tablet PC offers two options to complete the boot up Android 4 0 Aut
8. usiness Park Exeter United Kingdom Enquiries T 0844 840 3100 F 0844 480 3200 Online store www syxthsense com Online Store www syxthsense com Copyright 2013 SyxthSense Ltd Ver 0 2 Enquiries T 0844 840 3100 F 0844 840 3200 50 14 easyioKits User Manual 9