1. DPNET interface defective Replace interface Data cable not connected Check data cable correctly Data cable defective Replace data cable 9 Appendix Glossary DP DAIRYPLAN herd management program DPNET interface Interface for the data connection between DAIRYPLAN and the Westfalia peripherals connected DPNET equipment Network components eg METATRON feeding box gate contro units Herringbone milking parlour Additional processor for a DPNET device ISO reader Identification module for animal identification system Network processor for a DPNET device Network installation Addressing in the network Pin Unique identification number 48 bit for a DPNET device Side By Side milking parlour Scanning Address check on the DPNET devices linked to the network Signal Command from DPNETInstall to the DPNET device after successful installation Westfalia Landtechnik GmbH e Werner Habig StraBe 1 e D 59302 Oelde Tel 49 0 2522 77 0 e Fax 49 0 2522 77 24 88 e Internet http www westfalia com Production and Central Warehouse e MuhlenstraBe 17 20 e D 58313 Herdecke Tel 49 0 2330 64 0 e Fax 49 0 2330 13866 We always reserve the right to make structural and design modifications 7160 9001 517 16 04 2002
2. Reserve Min 1 Max 127 Erstes Metatron in emer fortlaufenden Feihe Min 1 2E nte Letztes Metatron in einer hortlautenden Reihe Min 1 2B ute Erates Metatron in einer fortlaufenden Reihe Min 1 Byte Letztes Metatron in einer fortlaufenden Rehe bMin 1 2E nte Erates Metatron in einer fortlaufenden Rehe Min 1 28 phe Letztes Metatron in einer fortlaufenden Aeihe Min 1 28 te Erstes Metatron in emer fortlaufenden Pele bMin 1 2E pte Letztes Metatron in einer fortlaufenden Reihe Min 1 2B yte l oP co oP mM oPeooowtost Bs e ain ir ea en ra a L Fb ek dC dC J Signals The signal command for the selected device is triggered by means of signals This command is carried out differently by the various devices es signal command METATRON P21 S21 LEDs will flash 3 times Gate control Gate rattles only when vacuum is connected Box control unit Gate rattles only when vacuum is connected Setting of configuration parameters Transfer of configuration data to the device selected without having to carry out installation This action can only be used for installed devices 7160 9001 517 04 2002 15 8 Malfunctions and Interference Malfunction Cause Remedy No data Incorrect settings in Check settings and adjust if connection DPSetup necessary Driver for DPNET interface Install and check driver not installed DPNET interface not Check installation installed correctly
3. see operating instructions for DAIRYPLAN e Install DPNET interface and install DPNET driver software see user manual for Installing DPNET interface e Enter settings in DPSetup for DPNET e Install DPNETInstall program and setup milking parlour settings Downloading equipment software install DPNET network Configuring the DPNET interface 2 1 Technical Data DPNET interface PCI card Operating systems Win 98 second edition Windows 2000 Windows XP Connection PCI CE Interference EN50082 1 IEC 801 2 801 3 801 4 immunity Emitted interference EN50081 1 EN55022 7160 9001 517 2 04 2002 3 Safety information Use in accordance with the intended purpose also includes complying with the operating manual and the conditions for inspection and maintenance Original Westfalia parts and accessories are designed specially for Westfalia components We would like to expressly point out that parts and accessories which we have not supplied will not be checked or released by us either Therefore the installation and or use of such products may possibly have a detrimental effect on structural properties specified The manufacturer will not accept responsibility for any losses arising as a result of using non original parts or accessories General safety information Permissible operating conditions pressure ranges temperature ranges air flow measurements etc are to be taken from the te
4. 1 Neuron ID Metatron 1 1 1 Neuron ID Metatron 2 1 2 Neuron ID Parl a side Reihe 2 Metatron 3 2 1 Neuron ID Metatron 4 2 2 Neuron ID P Sel Selektion Waage The PC shown in the tree should have a green background otherwise the DPNET interface has not been installed correctly If this icon is red the settings under Network installation gt Interface set up will need to be checked Program symbols 7160 9001 517 04 2002 The following pictograms may appear in the tree MUSA US METATRON Stand By E PODER directory Here the background colour provides information on the installation status Background colour Installation OK E eee Eamel sean of neuerntertace DPNET interface p METATRON OK a Installation incomplete Installation of METATRON IY Re install Ol incomplete Re install Installation incorrect Re install nstanation of gate control system incorrect Re install 5 1 Network installation Update Requirements e DAIRYPLAN DPNETInstall are installed e DPNET interface including drivers is installed e The equipment for the DPNET network which is to be put into operation eg a milking parlour or a feed box unit must be assembled in the milking parlour and connected to the DPNET interface of the PC e Settings have been entered in DPSetup for DPNET Before the network can be installed the installation is to be configured in DPSetup
5. ETATRON device a final check should be carried out on the METATRON settings on the device and they should be resent if necessary The installation update is complete 6 Installation procedure 6 1 Scanning the network When scanning the network DPNETInstall searches for current devices installed in the milking parlour and connected to the interface While doing so the addressing and configuration of all devices found are checked If any device is found to have an address which lies outside the permissible range or which already exists this will be indicated by the background colour of the device and possibly also by means of an error message Background colour Installation OK Installation incomplete Re install Installation incorrect Re install If the milking parlour has been installed correctly the following image will be shown e DPNet Install Mal E Lado Datei Ansicht Netzinstallation Ger tesoftware Ger te Info Verborgen Hilfe 59 x mejeje dpnet PC Futterstationen Melkstand 1 FGM y Standby Modul 1 103 1 Parl j Side Reihe 1 Torsteuerung 1 102 1 Metatron 1 1 1 Metatron 2 1 2 Parl I side Reihe 2 Metatron 3 2 1 Metatron 4 2 2 Selektion Waage ES Note During initial commissioning of DPNETInstall you will be automatically requested to scan the network Start the scanning process e Under Network installation select the option Scan net
6. Landtechnik REGISTER 16 Instruction Manual 7160 9001 517 04 2002 DPNET Install Installation program for DPNET network Printed in F R Germany Contents Preface Description Wale gi gil ac BJs O ene eae 2 Safety information Installing DPNETInstall Operation Network installation Update 0 00 nananana nananana nanana 6 Installation procedure SCANNING INE NETWORK 2 fs oa einai ose le Rese Re Hwee a See da eee ee a eee ee Sete ee ia eee ee 8 Downloading equipment software ooo 9 Assigning addresses to DPNET devices network installation 0 0c c cence teens 12 DPENETIMEN ICE e yah Si ote EE sts oe eas ie ats ate Govt eve ea ea ee iss See D 13 Equipment information Malfunctions and Interference Appendix Marks modifications to the previous edition Westfalia Landtechnik software corresponds to the current level of technology and meets the basic safety requirements of EC guidelines Notes from the manufacturer to the user On the basis of continuing development we reserve the right to make changes to the information and diagrams given in these instructions Reprints translations and duplications in any form even of extracts must have the written agreement of the issuer Notes for the owner The owner is responsible for ensuring that all safety instructions are followed and that this software is used in accordance with the in
7. To do this start up the Wizard via DPSetup gt Wizard gt Start Once all the forms have been filled in the milking parlour is configured and DPNETInstall can be started up Installinglupdating In order to install or update a network the following points are to be carried out in the order specified ES Note The installation described is restricted to essential components If necessary detailed information instructions on the points can be taken from the section entitled Installation steps e Start up the DPNETInstall program Directly from this DAIRYPLAN directory From DPSetup under the menu Devices gt DPNETInstall e Scan the network Call up the menu Network installation gt Scan network Tree will be displayed e Download equipment software for new device or update ES Note During initial commissioning only one Neuron download has to be carried out for the gate box control system as all other modules are supplied with plug and play Neuron host software Select the device to be installed in the tree background colour red or grey In the menu Equipment software select the menu point Neuron processor or Host processor for METATRON Call up via Tree only works when updating or Service Pin initial commissioning and updating Software ubertragen E x Wollen Sie die Software auf das ausgewahlte Gerat Ubertragen oder wollen Sie dat entprechende Gera
8. ce Pin e By making a selection in the tree Status query Display of status information on the Neuron x processor important for fault diagnosis rn a dE AmiErrs 0 Node state value must be the 1 se Nein es Configured Online value RcvTransFull 0 If the entry does not match a new Neuron ee 0 See 595 download must be carried out o If any faults occur make a note of the A eins verum 9 ResetCause value and inform the service ErrorLog No Error engineer if requested ModelMurn 11 Communication table query Display of the devices with which the device xj selected can communicate Communication Table from DP Subnet Node Version query Display of version information on the device Rest including the current version of software and K Host bath P hardware Eos Host ID Software version host and Boot Sattware Version Host 1 07 version only have an entry in the case of devices Pere ae with host software see Fig with METATRON as the example Kennung euman F2 Soltware Verrsion eurars 35 H ardware ersions HP 100 7160 9001 517 14 04 2002 Configuration data query The interactive window displays the configuration data on the device selected Ger te Parameter Konfigurationsdaten te x Config Data from DP f Contig Data from DFN et Metatron 1 11 7 Fal Mr Walue Factor Description Min Max Mins 1 Max 127 Eute
9. chnical specifications in this operating manual and are not to be exceeded Disconnect electrical installations or equipment before working on them Lock any main or emergency stop switches to prevent them from being switched on again and put up a warning sign Note that electronic components can be destroyed by electrostatic processes Work should only be carried out on the installation when it is disconnected from the power supply Selection and qualification of personnel basic obligations Read and follow the operating manual carefully Only use trained or briefed personnel Make sure that only authorised persons have access to the computer Work on electrical parts of the machine installation may only be carried out by skilled electricians or by briefed personnel under the direction and supervision of skilled electricians in accordance with electrotechnical regulations Saving data Data is to be saved after and before amendments are carried out Generally speaking data is to be saved at specific intervals and stored in a safe place Make several sets of backups so that if there is an error in one there is still another available Warnings and symbols The following designations and symbols are used to denote especially important information in this operating manual Note Special information on how to use the device economically Attention Special information or directions and prohibitions relating to loss preve
10. etatron 4 2 2 Attention Make sure that you send the Service Pin for the right device as otherwise this will cause malfunctions in network communications e Aftersending the PIN wait for the signal from the device eg METATRON will flash 3 times If this does not happen then check progress on the PC e Continue with the next device until all the devices have been installed After installing the last device a corresponding message will appear in DPNETInstall Application Download Bitte Service Pin drucken Metatron 1 11 erat Ubersprindern Abbrechern Reihe Uberspringen e Scan the network 7160 9001 517 12 04 2002 6 4 DPNET interface The DP computer must be equipped with a DPNET interface in order to enable the DP computer and the DPNET components to communicate with each other Installing the DPNET interface 7160 9001 517 04 2002 The interface installed is to be entered under Network installation gt Interface Setup In the case of the XLON PCI the following image will appear DPNetinterface N x r DPNHet ntertace Son PEI Interface Mr lo Clon USB C PCLTA20 Abbrechen Possible errors Unable to open LONTalk DPNET interface or driver Check installation adapter missing 13 7 Equipment information Here you can call up information on a device selected or call up actions There are two ways to select the device e By clicking on the Servi
11. l durch drucken des Service Fins Festlegen Sermice Fin Abbrechen Attention During initial commissioning call up the device using the Service PIN see corresponding user manual for the device 7160 9001 517 04 2002 7160 9001 517 04 2002 The program will propose the correct software automatically If necessary a message will appear indicating that the latest software version Is already available Carry out the download Download the next device e Assign addresses to DPNET devices Attention Please follow the relevant user manual for the device when installing DPNET equipment eg for METATRON Print out the installation tree to help with installation In the Network installation menu choose between Address assignment gt All Installation of all devices and Address assignment gt Single Installation of single devices Send the PIN to DP for each device one after the other in the order shown in the installation tree Ger teinstallation Xx Bitte drucken Sie den Service Pin Metatron 4 2 2 After sending the PIN wait for the signal from the device eg METATRON will flash 3 times Next device e Scan network again Once all devices have been linked up a final check will be carried out on the network If installed correctly all pictograms will have a green background e Close program Close in the File menu ES Note After installing a M
12. ntion 7160 9001 517 04 2002 3 4 Installing DPNETInstall Installation The program is installed during the installation of DAIRYPLAN Deinstallation Uninstallation is carried out when DAIRYPLAN is uninstalled 5 Operation Start of program The DPNETInstall program can be started as follows after installation e Directly from this DAIRYPLAN directory e From DPSetup under the menu Devices gt DPNETInstall Special features of the initial start up process When the program is started up for xj the first time the window displayed will appear automatically The following details must be entered E Rion PCI Interface Nr fo y once for the DPNET interface DPH et Interface C lon USB DPNET interface Xlon PCI In exceptional cases it may be PELTA 20 necessary to select a different interface Interface no 0 Abbrechen Finally you will be requested to scan the network 7160 9001 517 4 04 2002 On starting up the program window displaying the installation tree and devices based on the information in DPSetup will appear They will not have been recognised by the system and will therefore be displayed in grey or red DPNetInstall 0 1 a Datei Ansicht Netzinstallation Ger tesoftware Ger te Info Verborgen Hilfe 8 x E Fed Futterstationen Par sad eae Melkstand 1 FGM g Standby Modul 1 103 1 Neuron ID Parl Side Reihe 1 Torsteuerung 1 102
13. ressing the Tree button the file to be transferred will be displayed Press OK to confirm The program will propose the correct software automatically If the current version is already installed on the device a message will appear indicating that no download is necessary Carry out the download After the Neuron software has been transferred the device will have to be re installed DPNETInstall will do this automatically Continue the download process for the next device 11 6 3 Assigning addresses to DPNET devices network installation Attention Please follow the relevant user manual for the device when installing DPNET equipment eg for METATRON When installing the system each device will be allocated an address in the network and the devices will be configured First of all install all the DPNET devices within an installation Installation procedure e In order to ensure that the individual Service Pins are sent in the correct order you can print out the installation tree to help you by clicking on File gt Print e In the Network installation menu choose Address assignment gt All in order to install all the devices in the tree Address assignment gt Single in order to install a single device selected e Send the PIN to DP for each device one after the other in the order shown in the installation tree Ger teinstallation XxX Bitte drucken Sie den Service Pin M
14. tended purpose He must make sure that every user knows how to use the software computer and can operate them safely Only use computers which are in perfect working condition Technical terms special names or trade terminology used in these operating instructions are explained in more detail in the glossary contained in the Appendix 7160 9001 517 04 2002 2 Description Note DPNETInstall is included within the DAIRYPLAN Installation CDs from version 5 090 The DPNETInstall program is used to install and commission DPNET networks and carry out any modifications which need to be made to hardware and software in connection with new versions This involves entering various settings for the DPNET devices DPNETInstall also offers the following functions e Scanning the network in order to find out the current status of the installation e Updating of the equipment software by transferring Neuron and host software e Displaying network information The milking parlour will not be fully operational until all the connected devices are installed correctly Once installed the individual devices will be able to communicate not only with each other but also with DAIRYPLAN The following steps need to be taken in order to operate a DPNET network e Install DPNET equipment in the installation as well as the cabling required see relevant user manual and assembly instructions for the equipment e Install DAIRYPLAN on a PC
15. to be installed in the tree background colour red or grey e Inthe menu Equipment software select the menu point Neuron processor or Host processor host only for METATRON e Call up device Attention During initial commissioning call up the device using the Service PIN see corresponding user manual for the device To do this you select whether the device is to be called up via the Tree or by clicking on Service Pin software bertragen Woollen Sie die Software auf das ausgewahlte Gerat Ubertragen oder wollen Sie das entprechende Gerat durch drucken des Service Pins lesilegen SF earvice Fin Abbrechen Service PIN for initial commissioning and updates Is released on the device and sent to DPNETInstall DPNETInstall will wait for the Service Pin for the device Application Download Bitte Service Pin drucken Metatron 1 1 1 erat Ubersprinder Reihe Hberspringen After activating the Service Pin on the device the file to be transferred will be displayed DPNetinstall Die folgende Datei wird nun bertragen CDairyFinidonetlglobal P2136 a nxe Ok Abbrechen 7160 9001 517 10 04 2002 7160 9001 517 04 2002 Tree only works when updating devices already installed The whole process can be operated directly from the computer You only have this facility if the device selected has already been installed in the network After p
16. work 7160 9001 517 8 04 2002 6 2 Downloading equipment software 7160 9001 517 04 2002 DPNET devices operate using a Neuron processor METATRON using Neuron and host on which corresponding software may have to be run e For initial commissioning only applies to gate box control system e Forupdating applies to all DPNET devices To do this a standard control module is used for the gate and box control systems which is supplied with universal test software This control module eg a box control unit cannot be used until you have downloaded the corresponding equipment software Before the system can be installed it is therefore necessary to download the corresponding software to this module from the Equipment software menu via the menu point Neuron processor or Host processor The type of download will depend on the processor for the DPNET device used to run the equipment software Neuron processor Network processor used to run programs for single devices Host processor Processor which is used to run additional programs for complex devices METATRON The following table shows the existing device specific processor software Device Wewon ost cae a e e o Download process Note During initial commissioning only one Neuron download has to be carried out for the gate box control system as all other modules are supplied with plug and play Neuron host software e Select the device