Home
OMRON Tag Creator for Wonderware InTouch WindowMaker
Contents
1. automatically from cxt file PLC Type information plus underscore For example if PLC Type in cxt file is CVM1 V2 then new tagnames like following will be generated CVM1 V2 168 02 or CVM1 V2 High temp val2 After suitable tagnames prefix is selected click the Configuration button the Configuration dialog box will appear Configuration x File OMRHLINK v Node localhost Cancel Here the File and Node fields are used to select the cxt file to be used as a new source from where to generate new WindowMaker tags The combo box at right part of Configuration dialog box is used to select some of Klinkmann Omron Servers OMRHLINK OMRONFGV or OMRONETH to be used as current Application Name for InTouch data base Access Name definition For example select local node Node field can be empty default example cxt file supplied with OMRON Tag Creator installation and select OMRHLINK as current Application Name OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator Configuration N En x File nn Automations Omron Tag Creatorvesample cxt OMRHLINK v Hode Lancel Press OK the Omron Tag Creator main window will re appear now containing general Info area and list of all variables filled in Browse area based on information from example cxt file Omron PLC program memory addresses are put into AllVariables
2. the current Access Name information will be displayed in the Info area Omron Tag Creator Info l l Server Type OMRHLINK Access Name CVM THT POS DE BANE pace Generate About PLC CPU CPU Application Name OMRHLINK Items count 4095 Topic Name Ctl Pers Browse Tags Access Names Pretix IST l Filter Data Types R lt A 9 Select Al Reset All Select Al Reset All Create Access Name AlNerable Sein ai H Globa arnables n Loca ariables To edit the already existing Access Name double click on some existing one from Access Names list box the Edit Access Name dialog box will be invoked OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 9 Notes 1 The Server Type and Application Name both displayed in general Info area must be same e g OMRHLINK as in above example 2 The Topic Name entered in Add Access Name or Edit Access Name dialog box must match with some of existing Topic Names configured for corresponding Klinkmann Omron Server OMRHLINK OMRONFGV or OMRONETH For above example the Topic Name CVM must present in OMRHLINK Server configuration Now the configuring of OMRON Tag Creator settings for current cxt file example cxt is finished and creation of tags can be done Creating tags by OMRON Tag Creator There are two OMRON Tag Creator areas used to create tags for WindowMaker the Browse area
3. and the Tags area The Generate button is used to add the selected tags to InTouch data base Browsing the Omron PLC program variables The Browse area is used to select Omron PLC program data memory addresses and global and local variables available from currently selected cxt file In Browse area all Omron PLC program data are displayed by their new tagnames generated by OMRON Tag Creator based on cxt file contents and current tagnames prefix entered in Browse area Prefix field Omron PLC program memory addresses are put into AllVariables group For example for our example cxt program AllVariables can be expanded like following Browse Prefix CV2_ Select All Reset All E AllVariables a s s mannu s s The selection of variables in Browse area can be done in following different ways 1 Single variable can be selected by double clicking on it For example variable CVM1 V2 168 02 can be selected by double clicking on it in Browse area this variable will be added to Tags area OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 10 Browse Prefix Cv2_ Select All Reset Al aj DIM arable S Cy 166 00 Data Types fa 9 Select All Reset All Symbolic Name CY 166 02 CIO bell Discrete Cv2_215 08 oo 2_215 09 2 All group of variables can be selected by doub
4. group If in the InTouch application currently opened by WindowMaker there are already some Access Names defined containing OMRHLINK as an Application Name then these Access Names will be displayed in Access Names list box below the Create Acess Names button Omron Tag Creator Info Server Type MRHLINK Access Name PLE Type LCM Z HERE Generate About PLC CPU CPU Application Name Items count 4095 Topic Name Done Browse Tags Access Names Pretix IST Filter Data Types R lt All ka Select Al Reset All Select Al Reset All Y Allvariables Symbolic Name H Globalvarables n Local ariables s Create Dcrezz Name Adding editing Access Names New Access Names can be created directly from Omron Tag Creator main window by pressing Create Acess Names button and invoking the Add Access Name dialog box OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 8 Add Access Name Access Name Cu Cancel Hode Name Application Name OMRHLINK Topic Name EVM Which protocol to use C DDE fe SuiteLink When to advise server Advise all items fe Advise only active items After filling fields in Add Access Name dialog box and pressing OK the Omron Tag Creator main window will re appear with new Access Name displayed in the in Access Names list box CVM in our case By selecting CVM from Access Names list box
5. OMRON Tag Creator for Wonderware InTouch WindowMaker User Manual Ver 1 x Rev 1 0 PR 125 10 KLINKMANN AUTOMATION P O Box 38 FIN 00371 Helsinki Finland Tel int 358 9 5404940 Fax int 358 9 5413541 www klinkmann com Klinkmann Automation OMRON Tag Creator i Table Of Contents OMRON Tag Creator Ver 1 x User Manual Rev 1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 1 OMRON Tag Creator for Wonderware InTouch WindowMaker Overview The Klinkmann OMRON Tag Creator is an add on module for Wonderware InTouch WindowMaker used to expand the functionality and capability of InTouch at design time The Omron PLC programs created by the OMRON CX Programmer Windows Programming Software CX Programmer can be saved as binary cxp files or text cxt files Based on information about all PLC program variables included in cxt files the OMRON Tag Creator uses cxt files created by CX Programmer to help you create tags within InTouch quickly and easily The Klinkmann OMRON Tag Creator supports the following types of OMRON PLCs CS1 CJ1 Series PLCs CV Series PLCs C CPM2x PLCs C200HX C200HG C200HE PLCs CQM1 PLCs The following Klinkmann OMRON Communication Servers are supported by OMRON Tag Creator Klinkmann OMRON Hostlink Communication Server OMRHLINK using the Host Link protocol to communicate with OMRON PLCs directly via serial RS 232 RS 422 RS 485 interface Klinkmann OMRON FINS Gateway Co
6. P12510m10 Klinkmann Automation OMRON Tag Creator 12 iter Data Types R lt All ka Select All Reset Al CIOO1 6800 Discrete LI0016801 CIOO1 BS by selecting several consecutive variables by holding Shift key and at first clicking mouse left button on variable and then on last variable or non consecutive variables by holding Ctrl key and clicking mouse on variables to be selected Tags Filter Data Types R lt All ka Select All Reset All Symbolic Name v2 168 00 CIOOT6800 Discrete CY 169 01 CIOUT S01 Discrete Ca 169 02 LIO01ES0E Discrete by using Filter feature by entering the filtering mask in the Filter edit box and pressing lt Enter gt the variables matching the filtering mask will be selected like following the filtering is performed on Symbolic Names OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator Select All Reset Al Symbolic Name LV2 217 15 Cw 01051 LV 2 01052 LV 2 016012 LV 2 016013 LV 2 016014 LV 2 D16015 LV 2 D2615 LV 2 D2616 Cw D2620 LV2 D02621 10021715 01051 01052 016012 016013 016014 016015 02615 D2616 D2620 D2621 Discrete Integer Integer Integer Integer Integer Integer Integer Integer Integer Integer 13 by using Data Types feature by selecting some data types available lt All gt Discrete Integer Real from the Data Types combo box all this data type variab
7. button all currently selected variables will be deleted from Tag area Note variables in Browse and Tag areas are listed in alphabetical order Creating new tags The Tags area is used to create new WindowMaker tags from Omron PLC program variables previously added to Tags area by browsing and selecting in Browse area In Tags area each selected variable is located in one row consisting of three fields 1 Symbolic Name new tagname generated by OMRON Tag Creator this name will be used as Tagname in Window Maker Tagname Dictionary 2 Item Name item name associated with Symbolic Name by OMRON Tag Creator depending on corresponding Klinkmann Communication Server OMRHLINK OMRONFGV or OMRONETH item naming system this name will be used as Item in Window Maker Tagname Dictionary 3 Type the type of variable Discrete Integer or Real this will be used as tag Type I O Discrete I O Integer or I O Real in Window Maker Tagname Dictionary In general the creation of new WindowMaker tags is done the following way necessary variables are selected in Tags area and then by pressing the Generate button new tags are added to Window Maker Tagname Dictionary There are several ways how to select variables in Tags area by pressing Tags area Select All button all current Tags area variables will be selected OMRON Tag Creator Ver 1 x User Manual Rev1 0
8. f installing from distribution disks floppies 4 If installing from CD select Protocol Servers DDE SuiteLink OPC find Additional and support software OMRON Tag Creator and click on Setup 5 Proceed as directed by the OMRON Tag Creator Setup program Note Omron Tag Creator needs the InTouch 7 11 Patch04 or newer to be installed on PC where Wonderware WindowMaker is running If InTouch 7 11 Patch04 is not installed the Omron Tag Creator installation will be rejected When installation is finished the following files will be added to InTouch subdirectory e g C Program Files FactorySuite In Touch OMRONTAGC WZU The OMRON Tag Creator wizard DLL file This file will be renamed to OMRONTAGC DLL by WindowMaker when configuring adding new OMRON Tag Creator wizard OMTAGCR DLL Dynamic Link Library necessary for OMRON Tag Creator SYSTAGS DAT Data file used by OMRON Tag Creator The subdirectory specified as a folder where to install the OMRON Tag Creator files will contain the following files P12510Mxx PDF The OMRON Tag Creator User manual this file where xx is the current latest version of manual EXAMPLE CXT Example OMRON CX Programmer PLC program file LICENSE TXT Klinkmann Automation software license file When installation is finished start WindowMaker from WindowMaker Main Menu select Special Configure Wizard ActiveX Installation and open the Wizard Activex Installation dialog b
9. gCreator To start the OMRON Tag Creator in WindowMaker 1 Open the Wizards ActiveX Toolbar by clicking on Wizards ActiveX Toolbar button from WindowMaker Toolbars if Wizards ActiveX Toolbar button is not visible enable it by selecting View Wizards ActiveX Toolbar from WindowMaker Main Menu the Wizard Selection window displays Wizard Selection j P j pog x Windows Controls Wizard Description nn Cancel Add to toolbar Select Omron Tag Creator and press OK The Omron Tag Creator icon will appear somewhere on WindowMaker currently opened Window Remove trom toolbar 2 Locate the Omron Tag Creator icon by clicking on it and then double click on it to open the Omron Tag Creator main window OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 5 Omron Tag Creator an a i 92 x Info Server Type Access Name Configuration Node PLC Type _ ode ee TE Application Name PLE CPU Items count Topic Name Browse Prefi PLC Data Types S cal v Select Al Reset All Select Al Reset All teate Access Name Initially all the fields in this window are empty except Browse area Prefix field has default value PLC1 and Tag area Filter and Data Types fields have their default values and lt All gt The next step using the Omron Tag Creator is to c
10. le clicking on the group name For example all AllVariables can be selected by double clicking on it in Browse area all AllVariables will be added to Tags area Tags Data Types Select Al Reset Al J Browse Prefia CV2_ Select All Reset All BL A ariables Cv2 168 00 Cv 168 00 C10016800 Discrete s CV2 168 01 Cvy2 168 01 C10016301 Discrete CY 168 02 CY 166 02 CIOOT6302 Discrete pr c l IS Crete nn 2 215 05 10021505 Discrete im DV 15 05 Cv 215 06 CIDO21506 Discrete Le 279 08 Cv 215 07 CIO021507 Discrete LYS 218 017 Cv 215 08 C0021508 Discrete VZ 215 08 Cy2 215 09 CIO0021509 Discrete s CW 2 275 09 ESF nn A 3 All Omron PLC program variables all groups can be selected by pressing Browse area Select All button OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 11 Browse Prefix Cv2 Select All Reset Al T DUN anablez Global anables Local ariables Data Types lt All ka Select All Reset All ne O A500 06 Discrete Cw2 002 SEC 4501 03 Discrete CV DOT s pulsi 4507 01 Discrete CV 0 1 SEC 3501 00 Discrete Cvs DARCV 2 06 Discrete WZ__02L551 2 07 Discrete Vv 2 1 min ajas C300 Integer Vv 2 1 min ajas CODD Discrete CV 1 min pulsi 1310 00 Discrete CV 1 varst vir 7 03 Discrete Fie Ei By pressing Browse area Reset All
11. les will be selected like following Select All Reset All Symbolic Name LV2 21714 Cy2 217 15 Cy2 01051 LV 2 01052 Y2_DIEDTZ Y2_DIEDTS C2 Tai Dy 1 202 Cy2 T310 LV2 Tale Data Types Integer 9 LIUU21 14 10021715 DOS 01052 D16012 D16013 T 300 T 302 T310 Tale Discrete Discrete Integer Integer Integer Integer Discrete Discrete Discrete Discrete K By pressing Tags area Reset All button all currently selected variables will become unselected OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 14 KLINKMANN AUTOMATION OMRON Tag Creator Revision History Feb 2003 Rev 1 0 First Release OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10
12. mmunication Server OMRONFGV using FINS communications protocol to communicate with OMRON PLCs over Ethernet Controller Link Sysmac Link Sysmac Bus or Serial networks the OMRON FinsGateway software must be installed on MS Windows NT 2000 or XP to run the OMRONFGV Server Klinkmann OMRON Ethernet Communication Server OMRONETH using FINS communications protocol to communicate with OMRON PLCs directly over Ethernet network the OMRONETH Server does not need the OMRON FinsGateway software to be installed on computer where OMRONETH Server is running Installing the OMRON Tag Creator The Klinkmann OMRON Tag Creator installation package can be supplied 1 As a self extracting archive P12510xxx EXE if downloaded from Klinkmann s web site the xxx is the current latest version of the OMRON Tag Creator 2 From installation on CD 3 On two or three distribution disks floppies OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 2 To install the OMRON Tag Creator from the self extracting archive run the P12510xxx EXE and proceed as directed by the S7ETHMPI Server Setup program To install the OMRON Tag Creator from CD or distribution disks on MS Windows 1 Insert the CD with Klinkmann Software into CD drive or insert the OMRON Tag Creator Disk1 into a floppy drive A or B 2 Select the Run command under the Start menu 3 Run STARTUP EXE if installing from CD or SETUP EXE i
13. onfigure the Omron Tag Creator settings Note The Omron Tag Creator is used only by WindowMaker and is not needed at InTouch runtime when InTouch application is ready the Omron Tag Creator icon can be simply removed from WindowMaker window where it was located Configuring the OMRON Tag Creator Settings To configure the OMRON Tag Creator settings at first you must enter the suitable tagnames prefix for new tagnames to be created from memory addresses and global and local variables used in Omron PLC program contained in the current cxt file This tagnames prefix will precede the Omron PLC program memory address or symbolic name for global and local variables when generating new WindowMaker tagnames see Creating tags by OMRON Tag Creator section below There are two opportunities how to enter this tagnames prefix OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 6 1 Enter the prefix text directly in the Browse area Prefix field like following Browse Frefis Evz Select Al Reset Al In this case prefix CV2_ will be added to memory address or symbolic name For example for PLC program memory address 168 02 new tagname will be generated as CV2_ 168 02 or for PLC program global variable High_temp_val2 the new tagname will be generated as CV2 High temp val2 2 Leave the Browse area Prefix field empty in this case the prefix will be generated
14. ox OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 3 Wizard ActiveX Installation i ies E x Wizard Installation Activex Control Installation Installed Wizards Actives Controls InTouch Button Wizards InTouch Clock Wizards Femore InTouch Control Buttons Wizard InTouch Distributed Alarm Display InTouch Frame amp Panel Wizards InTouch Light Wizards InTouch Meter Wizards InTouch Runtime Tool Wizards InTouch Slider Wizards InTouch Switch wizards InTouch Test Display Wizards List of Uninstalled Wizards in CAPROGA AM FILE SFA s klinkmann Omron Tag Creator 000 Install Search Select the Klinkmann Omron Tag Creator from the List of Uninstalled Wizards and press Install Klinkmann Omron Tag Creator will be added to Installed Wizards To uninstall the OMRON Tag Creator 1 Remove it from Installed Wizards by selecting the Klinkmann Omron Tag Creator WindowMaker in Wizard ActiveX Installation dialog box and clicking Remove 2 Start Control Panel select Add Remove Programs and select the Omron Tag Creator from the list of available software products Click on Add Remove and proceed as directed by the UninstallShield program OMRON Tag Creator Ver 1 x User Manual Rev1 0 P12510m10 Klinkmann Automation OMRON Tag Creator 4 Setting up the OMRON Tag Creator Starting the OMRON Ta
Download Pdf Manuals
Related Search
Related Contents
3D Connexion OL-6666-03 Owner's Manual Sony LCM-CSVH Notes Scrambler Manuale d`uso e manutenzione LaCie LaCinema Classic HD, 1TB HP Promo 1TB 7200rpm SATA Tronçonneuse à chaîne diamantée MANUEL D`UTILISATION Samsung SGH-P400 Инструкция по использованию Descale Acer Aspire T180 Copyright © All rights reserved.