User Manual - ProSoft Technology

image

Contents

1. A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X MOD Master Page 55 Possible status values are Value Meaning 1 Boot mode 2 Configuration mode 4 Production mode Read Kernel Parameters The Utilities Read Kernel Parameters command displays various communications parameters for the currently selected AN X This command resets the AN X You will be warned and given the opportunity to cancel the command AEEA Area Connection 0x2 00 0c 1a 00 00 0a 192 168 0 10 AnxInit O x Configuration Utilities Edit Yiew Help XIR AnxInit Ready A AN X now in BOOT mode AN X Kernel Parameters console ttyS0 115200 ip 192 168 0 10 192 168 0 105 192 168 0 1 255 255 255 0 ANxX00000a eth0O none lu a For Help press F1 E a z The Utilities Read Kernel Parameters command leaves the AN X running the boot code Use the Utilities Restart AN X command to restart the AN X in production mode Run Config Mode The Utilities Run Config Mode command is used to restart the currently selected AN X in configuration mode normally used internally for updating firmware This command is not used in normal operation but may be required for technical support The AN X is in configuration mode when the SYS LED flashes red twice followed by a pause To exit configuration mode use the Utilitie
2. A product of Quest Technical Solutions 58 gt 2s Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X MOD Master Page 19 y Log Files v Administration Home Page AN X MOD MAS Modicon 908 RIO Configuration Modicon S968 RIO Configuration Instructions All configuration operations result in a disruption in the Modicon S908 RIO network and Ethernet IP connections These should not be performed with the PLC in run mode There are two ways to create a Modicon 5908 RIO configuration file Automatically scan the Modicon S908 RIO network using the link below This creates a new csv file on the AN X MOD MAS device and overwrites the current configuration file The new configuration file is based on the RIO slaves currently connected to your Modicon 5908 RIO network 9 Auto configure 5908 network Auto configure 5908 network and ControlLogix configuration OR Manually create a csv file using your editor of choice and use the form below to select the local file Use the Send button to apply this configuration file a Browse T AN X can generate a default ControlLogix data mapping configuration based on the I O it finds see page 24 If you want AN X to generate the ControlLogix configuration check Auto configure S908 network and ControlLogix configuration Otherwise check Auto configure S908 network the default
3. Click the Auto configure Network button AN X sends messages to all possible drops and builds a configuration based on the replies it receives AN X then displays the configuration it found Example Drop 4 Rack 1 slot 1 Type CPS_114_xx Addr d4s1 Inp 00 Out 00 AC PS 115 230V 10A slot 2 Type CRA_93x_00 Addr d4s2 lnp 00 Out 00 RIO DROP S908 slot 3 Tyoe DDI_353_00 Addr d4s3 Inp 04 Out 00 DC IN 24V 4x8 Slot 4 Type DDO_353_00 Addr d4s4 Inp 00 Out 04 DC OUT 24V 4x8 A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com ICAL SOLUTIONS Page 20 AN X MOD Master Manual Configuration AL SoLuTIONS November 2011 CfgLen 2 0x0000 0x0000 Slot 5 Type ACI_030_00 Addr d4s5 Inp 18 0Out 00 AN IN 8CH UNIPOLAR CfgLen 1 0x0001 Slot 6 Type ACO_020_00 Addr d4s6 Inp 00 0ut 08 AN OUT 4CH CURR CfgLen 6 0x8001 0x5555 0x0000 0x0000 0x0000 0x0000 EndDrop Drop 5 Rack 1 Slot 2 Type B810 Addr d5s2 Inp 00 Out 01 8 OUT ISO B810 Slot 3 Type B804 Addr d5s3 Inp 00 Out 02 16 OUT B804 Slot 4 Type B863 Addr d5s4 Inp 08 Out 00 REG 4 CH IN B863 EndDrop When AN X creates a configuration file it includes comments in the file it creates based on the information in its module database If you edit the automatically generated configuration file edit the comments as well See page 23 for informatio
4. A product of Quest Technical Solutions gt es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 54 AN X MOD Master Restart an AN X AN X Info November 2011 You must enter a default gateway address that is valid for the subnet even if there is no device at the gateway address on the network Click OK to complete the configuration Use the Utilities Restart AN X to restart the AN X in production mode If you Cancel the Utilities AN X IP Configuration command AN X is left running in boot mode Use the Utilities Restart AN X command to restart the AN X Use the Utilities Restart AN X command to restart the currently selected AN X in poduction mode The Utilities AN X Info command provides information about the currently selected AN X in the log window The information shown AN X Info Ethernet MAC address SerNum Serial number DaughterID Daughterboard ID 10 for AN X MOD Master BootRev Boot code version ConfigRev Configuration kernel version ProdRev Production kernel version HwRev Hardware version FirmwRev Firmware release version depends on current operating mode Status see below Vendorld Vendor ID ProdId Product ID IpAddrStr AN X IP address HostName AN X host name AL SoLuTIONS In boot mode FirmwRev Vendor ID and Product ID and not valid and IpAddrStr and HostName are not shown
5. Select the Configuration Firmware Update command to start the firmware update wizard A product of Quest Technical Solutions b gt e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER AN X MOD Master Page 57 Step 1 In step 1 you identify the AN X you are configuring Step 1 AN X Selection x Select this computer s Ethernet adapter that s on the same Ethernet subnet as the AN lt module you want to configure you may only have one Ethernet adapter in your computer Local Area Connection x Enter the Ethernet MAC Address of the AN module you want to configure ou can get this from the label on the AN module or by selecting Utilities Locate All AN Modules if the module s current IP address is on the same subnet 0 0 1 a 00 00 09 Enter the IP address on the local subnet that you intend the AN module to use 192 168 0 9 1 Select the Ethernet adapter that s connected to the AN X In most cases there will be just one Ethernet adapter in the computer The AN X must be on the same subnet as the computer 2 Enter the MAC address of the AN X you are updating This is printed on the AN X label It consists of six pairs of hexadecimal digits separated by hyphens In the example above it s 00 Oc 1a 00 00 09 If the AN X is already online you can obtain its MAC address using the Utilities Locate All AN X Modules command 3 Enter the
6. Connection Module Info Port Configuration Port Diagnostics Backplane 1756 ENBT 4 1756 10 100 Mbps Ethernet Bridge Twisted Pair Media Allen Bradley ENBT nsMod Address 7 Host Name C Host Name Type Vendor Parent Name Description Comm Format N one Y Slot Revision Status Offline f 6 Chassis Size f 7 fi fi a Electronic Keying Disable Keying Cancel Set the Slot to 16 Set the chassis size to 17 Set the Comm Format to None Set the IP address to match the AN X module Set Electronic Keying to Disable Keying Record the Name as you will use it if you create tags to access the data 2 Add Generic modules for each required connection A product of Quest Technical Solutions so oi Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X MOD Master Page 35 E Module Properties AnxMod 0 1756 MODULE 1 1 General Connection Module Info Backplane Type 1756 MODULE Generic 1756 Module Parent AnxMod Connection Parameters Assembly nseres Size Name AnwSlot0 Input 250 16 bit Description Output Configuration jo H 8 bit Comm Format input Data INT z Status Input Slat 0 Status Output Status Offline E Cancel Apply Help Set the parameters as shown Set the Slot to 0 for the first connection 1 for the
7. server If you are connecting AN X to an existing Ethernet network consult the network administrator to obtain a static IP address for AN X and to obtain information about how you should configure AN X The AN X must be on the local Ethernet same subnet as your computer when you set its IP address You configure the Ethernet properties using the Windows utility AnxInit supplied with AN X or the AN X web interface Use the Configuration AN X IP Settings command to start the AN X IP configuration wizard which takes you step by step through the IP configuration process Step 1 In step 1 you identify the AN X you are configuring A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X MOD Master Page 9 Step 1 AN X Selection Select this computer s Ethernet adapter that s on the same Ethernet subnet as the AN X module you want to configure you may only have one Ethernet adapter in your computer Local Area Connection 2 v Enter the Ethernet MAC Address of the AN x module you want to configure You can get this from the label on the AN lt module or by selecting Utilities Locate All AN Modules if the module s current IP address is on the same subnet 00 0c 1 a 00 01 0d Enter the IP address on the local subnet that you intend the AN module to use 192 168 0 105 1 Select the Ethernet adapter that s
8. A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com Page 62 AN X MOD Master November 2011 Using the Web Interface The AN X module contains a webserver capable of commuincating with standard web browsers such as Internet Explorer Use the web interface to e set the S908 remote I O network configuration e set the ControlLogix scheduled data configuration e view the current configuration e view AN X logs To use the web interface you need to know the IP address of the AN X Use the Utilities Locate All AN X Modules command in AnxInit to find all AN X modules on the Ethernet network To access the web interface start your web browser and type the AN X IP address where you normally enter web addresses in the browser AN X MOD MAS Modicon 8908 RIO Ethernet Gateway Introduction This is the main configuration screen for the Modicon S908 RIO Ethernet gateway product v Log Files Directions Administration The main menu located on the left provides a list of options that can be configured using this web interface To see the sub menus for each item click on the down arrow icon beside each main option Menu Details Automation Network Contains all the option pages that pertain to the Modicon S908 network 908 I O Network Configuration This screen is used to configure the Modicon S908 IO network options of the AN X MOD MAS S908 RIO
9. Reconfiguring an AN X from an Unknown State It sometimes happens that an AN X has been previously configured with an IP address that causes it to be inaccessible on the current Ethernet network To reconfigure it to a known state run the command Configuration AN X IP Settings to start the AN X IP Configuration Wizard and reconfigure AN X A product of Quest Technical Solutions Be ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 18 AN X MOD Master Autoconfiguration AL SoLuTIONS November 2011 S908 Network Configuration Before you can scan a Modicon S908 remote I O network you must configure the network in the AN X MOD Master There are two methods of configuring the S908 remote I O that the AN X MOD Master is to scan e autoconfiguration The AN X MOD Master reads the network contents by sending messages to the attached network and building the configuration from the replies it receives manual configuration You build a configuration file and send it to the AN X MOD Master You can also use autoconfiguration to build an initial configuration file edit the file to add or change features then perform a manual configuration with the modified file Before you can perform an autoconfiguration the remote I O network must be connected to the AN X From the AN X web interface select Automation Network S908 I O Network Configuration
10. e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 46 AN X MOD Master November 2011 9 Upload the alias files from each AN X and save them Import them into RSLogix 5000 There will be some errors from duplicates 10 Create the ControlLogix application 11 Add connections to both AN X modules 12 Add logic to detect the active AN X and to detect the switch from primary to backup see sample 13 On each scan copy the inputs from the active AN X to an internal array 14 On each scan copy an output array to the outputs on the active AN X 15 Write the control program in terms of the internal arrays Sample Application The following ladder logic shows a sample application that implements redundancy It first checks that connections to both AN X modules are good Generate OK status for all connections to ANX_A and ANX_B Module by checking that 1 Oxffff is not in the first two words of Input Data NEQ ANX_A_Connections_OK Not Equal Source A ANX_A 0 L Data 0 o Source B 1 NEQ Not Equal Source A ANX_A 0 LData 1 0e Source B 1 NEQ ANX_B_Connections_OK Not Equal lt Source A ANX_B 0 1 Data 0 0 Source B 1 E t Not Equal Source A ANX_B 0 Data 1 0 Source B 1 A product of Quest Technical Solutions Sold and Supported by ProSoft Te
11. eGo Links e s YY BSAC Web Qsearchste g E1743 blocked fRaloptions a cha pa AN X MOD MAS Active Configuration Log 3908 1 0 Network Configuration Ethernet lP View Configuration Files won an AN X NOD MAS I O Network Config File home axctr1 ModRioCfg csv 21 d05s1 ACO 020_00 40001 View Active Configuration 23 d05s2 DDO_353_00 1 25 Drop 5 O 12 I 0 MS 2 Parse Successful Click the Modicon S908 network link to view the current I O network configuration Click the Ethernet IP link to view the current ControlLogix scheduled data configuration A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL SOLUTIONS Log Files System Error Log System Info Log ControlLogix Log View All Logs Administration Menu Browse File System AL Solutions AN X MOD Master Page 67 AN X maintains various logs to record diagnostic and error messages Use the Log Files menu in the web interface to view these logs The System Error log records errors that occur during AN X operation This log is normally empty The System Info Log records informational messages during startup and normal operation The Ethernet IP log shows messages and errors associated with the ControlLogix scheduled data operation Use View All Logs to list and view all the AN X logs To view a log file double click on the file name The Administ
12. that contains the length of the parameter data in words and the parameter data itself A product of Quest Technical Solutions E ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions Page 22 AN X MOD Master AL SoLuTIONS November 2011 Example Slot 6 Type ACO_020_00 CfgLen 6 0x8001 0x5555 0x0000 0x0000 0x0000 0x0000 The leading Ox indicates a hexadecimal number Some Quantum discrete output modules for example the DRA 840 00 can be configured to either set their outputs either to the last value or to a user defined value when they lose communication with the network master To set these modules to hold their last state add a line after the slot definition that contains the keyword CfgOutLast Example Slot 4 Type DRA_840_00 CfgOutLast If you use both CfgOutLast and additional numerical parameters they can be on the same line or on separate lines CfgOutLast should be first If you do not enter any parameter data AN X uses the default parameters from its module database Refer to the document AN X MOD Parameters supplied with the AN X for detailed information about parameters for specific Quantum modules Sample RIO Configuration File In this example drop 1 is an 800 series drop and drop 2 is a Quantum drop Drop 1 Rack 1 Slot 4 Type B804 Slot 5 Type B805 Rack 2 Slot 4 Type B888 EndDrop Drop 2 Rack 1 Slo
13. the DHCP server assigns it an IP address You can use the utility AnxInit to find the IP address that the DHCP server has assigned Select Utilities Locate All AN X Modules and AnxInit will locate the AN X and display its IP address I Local Area Connection 2 0x2 00 Oc 1a 00 01 0d 192 168 0 105 Anxinit DBR Configuration Utilities Edit View Help Found 1 AN X device s O000010d Ethernet MAC 00 0c 18 00 01 0d iMeTe abyss U0 aL AnxzMod For Help press F1 A product of Quest Technical Solutions Be os Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS Page 8 AN X MOD Master IMPORTANT IMPORTANT IMPORTANT AL SoLuTIONS November 2011 If AN X does not find a DHCP server within about three minutes of starting up it reverts to a temporary static IP address of 192 168 0 41 If AN X is using this temporary IP address it repeatedly flashes the SYS LED red three times followed by a pause If your computer is on the same subnet you can use the web interface to change the IP address Use this temporary IP address only for initial setup of AN X AN X will not function for its intended purpose at the temporary IP address If you are using multiple AN X modules configure them one at a time especially if there is no DHCP server on the network since they will all revert to the same temporary IP address when they fail to find a DHCP
14. to reduce the Ethernet traffic since the diagnostics do not need to be updated as frequently as I O data Diagnostic Counters The AN X MOD Master maintains the following diagnostic counters Counter Offset Description TxCount 0 Transmitted network frames RxGood 1 Received frames with good status RxPrtcl 2 Received frames with a protocol error RxNoise 3 Received frames with a noise error RxTout 4 Receive timeout Scanner sent a message to a drop but did not receive a reply within the timeout period RxCre 5 Received frames with a CRC error RxOvr 6 Received frames too long RxAbort 7 Received frames with an abort error RxShort 8 Received frames too short RxErrMask 9 Error mask for protocol errors To map the diagnostic counters include a line with the keyword DiagCtrs in the input section of a connection This maps all ten diagnostic counters they cannot be mapped individually Examples DiagCitrs 10 DiagCtrs offset 10 A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com ote a Q9 PROSOFT PARTNER PROGRAM TIP AL Solutions AN X MOD Master Page 29 Drop Error Table The drop error table consists of 2 16 bit words one bit per drop Bit 0 of the first word corresponds to drop 1 bit 1 corresponds to drop 2 and so on Ifa configured drop is in error the bit is 1 If
15. E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SoLuTIONS AN X MOD Master Page 41 ControlLogix Ethernet Backup AN X Primary AN X Splitter Trunk Terminator Drop Drop Drop Drop Without the Redundancy Terminator Kit The AN X modules should be located at the physical ends of the network trunk The AN X modules have built in termination so no additional termination is required on the network trunk A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 42 AN X MOD Master ControlLogix Primary AN X ControlLogix Ethernet Configuration File November 2011 Ethernet Backup AN X 908 Network The following elements of the ControlLogix configuration file are used in redundant applications or have their usage slightly changed in redundant applications Parameter Description RedundEna RedundPrefix RedundEna must be included at the beginning of the ControlLogix configuration file and is followed by the redundant prefix for the module RedundPrefix is used to create aliases RedundCtl Must be mapped to the output data for the connection to slot 0 ScanSts Scan status table can be mapped to the input data for any connection LongInput Forces 800 series drops to send inpu
16. Modicon data The ClxName definition consists of a line with the keyword ClxName followed by a comma and the name you gave the emulated ENBT see page 31 Example ClxName AnxMod When AN X automatically creates a configuration file it uses the Ethernet host name as the default ClxName ClxPrefix The ClxPrefix is used in the alias names AN X creates for import into RSLogix 5000 AN X prefixes each tagname with the ClxPrefix The ClxPrefix can be used to distinguish tags for the same Modicon address when the ControlLogix processor has connections to more than one AN X MOD Master For example if the ControlLogix has connections to two AN X MOD Master modules each controlling a different Modicon network each network could have a Modicon I O module with the same drop and slot address Use a different ClxPrefix in the configuration file for each AN X MOD Master so that the tags for the two modules are unique The ClxPrefix consists of a line with the keyword ClxPrefix followed by a comma and the prefix text Example ClxPrefix MOD _ Scheduled Connection Data Each scheduled connection to the AN X begins with a line that consists of the keyword ClxSlot followed by a comma and then a number from 0 to 15 Example ClxSlot 0 A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions Page 26 AN
17. November 2011 AN X TCP IP Configuration Enter the IP configuration you want the previously selected AN module to use You MUST enter a valid Default gateway IP address that is on the same subnet as the AN X module but you don t need to have a device at that address Host Name AnxM od Obtain an IP address automatically DHCP Use the following Settings IPAddress 192 168 0 105 Subnet mask 255 255 255 0 Default gateway 192 168 O0 1 Cancel Enter an IP Address In this case we chose 192 168 0 105 Enter the same Subnet mask and Default gateway that you entered for the computer The default gateway address does not exist on the network but AN X requires that the field have a valid entry Click Finish to accept the settings Select Utilities Restart AN X to restart AN X with the new parameters When the AN X has restarted SYS LED is solid green select Utilities Locate All AN X Modules and confirm that the AN X is found with the new parameters A product of Quest Technical Solutions so 26 Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X MOD Master Page 17 I Local Area Connection 2 0x2 00 Oc 1a 00 01 0d 192 168 0 41 Anxinit SEE Configuration Utilities Edit View Help Ba x iN 2 Found 1 AN X device s 0000010d Ethernet MAC 00 0c 1a 00 01 0d is abetsh 0 alge AnxMod For Help press F1
18. address about 3 minutes Select the second option on the screen and click the Next gt gt button Step 3 Wait for AN X to enter config mode While AnxInit is waiting the Next gt gt button will be disabled When AN X is in boot mode the Next gt gt button will be enabled A product of Quest Technical Solutions b gt e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions AN X MOD Master Page 59 Step 3 Wait for Config Mode xj If you selected the Cycle Power option power ON the AN lt module now If you selected the Reset Command option a reset command has been sent to the AN module This program is now sending messages to the AN X module using the MAC address and IP address you entered previously These messages tell the AN module to enter into Config state in preparation for updating the firmware If the AN module enters Config mode successfully the Next button below will be enabled so you can move on to the next step If the AN module has been powered ON for more than 60 seconds and the Next button is still disabled press the Back button confirm the MAC and IP addresses and check the Ethernet cabling Next gt gt If the AN X does not enter config mode within about 60 seconds return to the previous screens and check the entries Click the Next gt gt button and select the firmware file you want to download a
19. available Ethernet bandwidth you can organize the data so that items that must update quickly are mapped to connections with short RPIs and items that are less time critical are mapped to connections with longer RPIs In addition the AN X module has diagnostic data that can be mapped to ControlLogix scheduled input data The mapping file can also contain options that apply to the entire configuration Anything after a semicolon is treated as a comment Mapping I O Data You map Modicon input and output data to the ControlLogix scheduled data by creating a comma separated variable file that defines the mappings A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SoLuTIONS AN X MOD Master Page 25 The file consists of sections for each scheduled connection Within each scheduled connection there are definitions for the input and output data for that connection that refer to the Modicon module drop rack and slot where the data is to be found When you create a mapping for a module all the input or output data for the module is mapped you cannot map individual registers AN X can automatically create a default mapping file when you autoconfigure I O See page 18 for details ClxName The first line in the file identifies the AN X module AN X uses this name in the ControlLogix alias tags it creates for the
20. second connection and so on 3 Set the RPI for each connection to match the RPI of the exclusive owner connection E Module Properties AnxMod 0 1756 MODULE 1 1 General Connection Module Info Backplane Requested Packet Interval RPI my ms 0 2 750 0 ms P Inhibit Module I Major Fault On Controller If Connection Fails While in Run Mode m Module Fault Status Offline n Cancel A product of Quest Technical Solutions so Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS Page 36 AN X MOD Master November 2011 Ensure that any check box that refers to Unicast connections is IMPORTANT unchecked ControlLogix Alias Tags AN X uses the Ethernet IP configuration to create alias tags that can be imported into RSLogix 5000 Use these tags in your RSLogix 5000 program to access the data on the AN X Even if the ControlLogix address for a Modicon address changes all you have to do is re import the tags If you change the Modicon or ControlLogix configuration re import tags so that the ControlLogix processor uses the correct addresses WARNING There are two sets of tag files one for the exclusive owner connection and one for the input only connection In the web interface select Automation Network View Configuration Files To view the files click either AN X MOD Ethernet IP ControlLogix Exclusive Owner Data Ta
21. the status byte for slot 1 is found in the high byte of the first word and so on A product of Quest Technical Solutions gt e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 30 AN X MOD Master AL SoLuTIONS November 2011 To map the module status data for a given Quantum drop include a line with the keyword dnModSts where n is the drop number from 1 to 32 in the input section of a connection Examples d4ModSts 30 d4ModSts _ offset 30 Connection Statistics The module maintains statistics for each exclusive owner scheduled connection In the following table O represents the connection originator ControlLogix and T represents the connection target AN X There are 10 words of data for the connection Offset Description 0 Average time for last 100 CLX to AN X updates 1 Minimum time for last 100 CLX to AN X updates Maximum time for last 100 CLX to AN X updates Maximum CLX to AN X time since connection opened Reserved Average time for last 100 AN X to CLX updates Minimum time for last 100 AN X to CLX updates Maximum time for last 100 AN X to CLX updates Maximum AN X to CLX time since connection opened Ol aOl AIT NDI nn AIIN Reserved The units for the times are 0 1 milliseconds A value of 87 means 8 7 ms To map the statistics for a given connection include a line w
22. AN X MOD Master Modicon User Manual S908 Remote I O Scanner Module Network A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com SOLUTIONS Page 2 AN X MOD Master November 2011 Because of the variety of uses for the products described in this publication those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements including any applicable laws regulations codes and standards In no event will Quest Technical Solutions be responsible or liable for indirect or consequential damage resulting from the use or application of these products Any illustrations charts sample programs and layout examples shown in this publication are intended solely for purposes of example Since there are many variables and requirements associated with any particular installation Quest Technical Solutions does not assume responsibility or liability to include intellectual property liability for actual use based upon the examples shown in this publication Throughout this manual we use notes to make you aware of safety considerations Throughout this manual we use notes to make you aware of safety considerations Identifies information about practices or circumstances that can lead to personal injury or death propert
23. Ethernet gateway Home Page Configure ControlLogix Support SESE e The left pane contains commands Click on the arrows at the left of the main headings to expand or contract the sections A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AN X MOD Master Page 63 The contents of the right pane depend on the current command being executed S908 I O Network Select Automation Network S908 I O Network Configuration to configure the I O the AN X MOD Master is to scan 1 12 Microsoft Internet Explorer AN X MOD MAS Modicon 908 RIO Configuration Modicon S908 RIO Configuration Instructions All configuration operations result in a disruption in the Modicon S908 RIO network and Ethernet IP connections These should not be performed with the PLC in run mode There are two ways to create a Modicon S908 RIO configuration file Automatically scan the Modicon S908 RIO network using the link below This creates a new csv file on the AN X MOD MAS device and overwrites the current configuration file The new configuration file is based on the RIO slaves currently connected to your Modicon S908 RIO network v Log Files yY Administration Auto configure S908 network Auto configure S908 network and ControlLogix configuration E OR Manually create a csv file using your editor of choice and use the form below to select the loca
24. IP address of the AN X you want to update Step 2 In step 2 you choose a method of restarting AN X to put it in config mode A product of Quest Technical Solutions E ei Sold and Supported by ProSoft Technology Inc PROSOEFT www prosoft technology com PARTNER PROGRAM Page 58 AN X MOD Master November 2011 Step 2 Cycle Power or Reboot Command x In order to configure the IP address or update the module s firmware the module must be be set to a specific mode There are two ways to do this 1 Cycle power on the AN Module This is the preferred method but the AN module must be nearby If you choose this option POWER OFF the 4N lt module and click on the Next button C 2 Send a command on Ethernet that restarts the AN X module This method is more convenient if the module is not nearby If you choose this option make sure the AN gt module is powered ON and fully up and running then click on the Next button lt lt Back The preferred method is to cycle power on the AN X Select the first option on the screen and click the Next gt gt button The second method useful if the AN X in not easily accessible is to send it a command over Ethernet The AN X must be powered on and completely running for this method to work For example if this is the first time you are configuring a new AN X allow sufficient time for it to acquire an IP address from a DHCP server or to time out and use its default IP
25. LED labelled 100 is on if the link is running at 100 Mbits second and is off otherwise The green Link Act LED is off if the link is inactive and is on if the link is active If activity is detected the link blinks at 30 ms intervals and continues blinking as long as activity is present SYS LED The SYS LED is used by the AN X operating system and software to indicate the state of operations and errors Errors or status indication in boot mode cause the LED to flash yellow Otherwise the LED flashes red The SYS LED should be used in conjunction with the logs to locate the cause of problems In the following red 3 means three red flashes followed by a pause and so on SYS LED State Possible cause Red 2 AN X is in config mode Red 3 DHCP configuration failed Red 4 Fatal application error check logs for cause Red 5 Application memory access violation check logs Red 6 Application failed illegal instruction check logs Red 7 Application crashed unknown cause check logs Fast red flash Reconfiguration set station number and baud rate failed Single red flash Unscheduled messaging addressing or connection problem Slow red flash Script or application problem during startup A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SoLuTIONS AN X MOD Master Page 71 At s
26. O000000aR Ethernet MAC 00 0c 1a 00 00 0a 192 168 0 10 ANXOOO00a For Help press F1 Selecting an AN X Before you can perform an operation on an AN X you must select which AN X you want the operation performed on Choose Utilities Select An AN X to select a specific AN X Set Ethernet amp IP Address xi Adapter Local Area Connection Ethernet MAC Address 0 0 1 a 00 00 0a IPAddess 192 168 0 10 Cancel From the Adapter list select the network adapter that connects to the Ethernet network that contains the AN X In the Ethernet MAC Address field enter the MAC Address of the AN X you wish to select It can be found on the AN X label or by using the Locate All AN X Modules command The format is as shown above six pairs of hexadecimal digits separated by hyphens In the IP Address field enter the Ethernet IP address of the AN X you wish to select It can be found using the Locate All AN X Modules command The format is as shown above four decimal numbers each in the range 0 to 255 Both MAC address and IP address must match the settings on the AN X in order for communication to occur A product of Quest Technical Solutions b gt e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Saturions AN X MOD Master Page 53 Click OK to select the AN X The title bar of AnxInit shows the MAC Address and IP Address of the currently
27. Patch Firmware The Utilities Patch Firmware command applies small patches to the firmware running on the AN X These patch files files have extension pch A product of Quest Technical Solutions ED e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER AL Solutions AN X MOD Master Page 61 Look in a downloads e ae a anxdes v1 00 0002 pch a anxdes v1 01 0006 pch a AnxDcsEnetIp_ anxdes v1 00 0004 pch a anxdes webupdate pch a nxDcsEnetIp_ a anxdes v1 00 0006 pch a AnxDecsEnetIp_1 1 18 pch 4nxDcsEnetIp_ anxdes v1 00 0007 pch a AnxDesEnetIp_1 1 19 pch a AnxDcsEnetIp_ a anxdes v1 00 0008 pch 4nxDesEnetIp_1 1 20 pch a 4nxDcsEnetIp_ a anxdes v1 00 0009 pch AnxDcsEnetIp_1 1 21 pch a AnxDcsEnetIp_ AnseDcsEnetlp 1 1 48 Files of type Jars Firmware Patch File pch x Cancel J Open as read only File name 4 This command resets the AN X You will receive a warning and be given the opportunity to Cancel the command You do not have to reconfigure the AN X after applying a patch All configuration information will be left intact When the patch has been applied AnxInit restarts the AN X in production mode If you cancel at the filename dialog the AN X has already been reset and is in configuration mode Use the Utilities Restart AN X command to restart it in production mode
28. The preferred method is to cycle power on the AN X Select the first option on the screen and click the Next gt gt button An alternative method useful if the AN X in not easily accessible is to send it a command over Ethernet The AN X must be powered on and completely running for this method to work For example if this is the first time you are configuring a new AN X allow sufficient time for it to acquire an IP address from a DHCP server or to time out and use its default IP address about 3 minutes Select the second option on the screen and click the Next gt gt button Step 3 Wait for AN X to enter boot mode While AnxInit is waiting the Next gt gt button is disabled When AN X is in boot mode the Next gt gt button is enabled A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X MOD Master Page 11 Step 3 Wait for Boot Mode If you selected the Cycle Power option power ON the AN lt module now If you selected the Reset Command option a reset command has been sent to the AN module This program is now sending messages to the AN lt module using the MAC address and IP address you entered previously These messages tell the AN module to remain in its Boot state in preparation for configuring the IP settings If the AN module enters Boot mode successfully the Next button below wi
29. X MOD Master AL SoLuTIONS November 2011 Each scheduled connection consists of output data and input data Scheduled outputs from the ControlLogix processor for that connection begin with a line with just the keyword DataOutput Scheduled inputs to the ControlLogix processor for that connection begin with a line with just the keyword DataInput Data definitions consist of lines that define the mapping between the ControlLogix data table and the Modicon I O module location drop rack and slot They consist of lines of the form CLX_offset optional Modicon_Location itemname The CLX_offset is the offset into the ControlLogix data for the connection You can select the offset where the data is located or you can leave it blank and AN X will automatically assign the offset The Modicon_location consists of an address in the form dxrysz where x is the drop number from 1 to 32 y is the rack number from 1 to 5 and s is the slot number from 1 to 16 If the rack number is 1 the explicit rack number ry can be omitted The itemname is a name you assign to the data When AN X creates aliases to import into RSLogix 5000 it builds the alias name from the ClxPrefix and the itemname If AN X autoconfigures the network it creates an item name based on the Modicon location and data type You can edit the configuration file and change the name to something meaningful in terms of the control system before you generate aliase
30. _Drops_OK ANX_B_Drops_OK ANX_B_Connections_OK Enable ANX_B scanner if there is no Duplicate Master detected If we have detected duplicate master ANX_A and ANX_B ScanSts in Scan state 2 enable scanning if All drops on ANX_B have good status or We don t have good connections to ANX_A MOD_B_RedundCtl 0 ANX_B_Connections_OK ANX_Dupl_Master lt ANX_B 0 0 Data 0 0 gt ANX_B_Drops_OK ANX_A_Connections_OK Check that AN X_A is the active scanner Indicate ANX_A is our active scanner if we have a good connection to it and its ScanSts is Scanning 2 ANX_A_Connections_OK ANX_A_Active QU Equal Source A MOD_A_ScanSts A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com Page 48 AN X MOD Master November 2011 Take inputs from the active scanner If ANX_A is Active use its inputs ANX_A_Active A 7 3 E Copy File Source ANX_A 0 I Data 0 Dest ANX_Input_0 0 Length 250 COP Copy File Source ANX_A 15 1 Data 0 Dest ANX_Input_15 0 Length 250 If ANX_A is not active use input from ANX_B ANX_A_Active COP 8 i Copy File Source ANX_B 0 l Data 0 Dest ANX_Input_0 0 Length 250 COP t Copy File Source ANX_B 15 Data 0 Dest ANX_Input_15 0 Length 250 Send outputs to b
31. a configured drop is responding correctly the bit is 0 The bit is 0 for an unconfigured drop To map the drop error table include a line with the keyword DropErr Examples DropErr 10 DropErr offset 10 Map the drop error table to the first two words of input data of each connection If the connection to the AN X module is lost the ControlLogix sets the first 2 words of the connection to FFFF hexadecimal If your program is monitoring the drop error table it will see all the error bits set Module Health Bits Each Modicon drop returns 5 words of module health data Each word corresponds to a rack the first word corresponds to rack 1 the second corresponds to rack 2 and so on Bits in the word correspond to a slot The bit is 1 for a correctly functioning module and 0 otherwise To map the health bits for a given drop include a line with the keyword ModnHth where n is the drop number from 1 to 32 in the input section of a connection Example Mod2Hith 20 Mod2Hlth offset 20 Note the module health bits do not update if the drop is offline or if the connection to the AN X module is lost Quantum Module Status Data Quantum modules each return a byte of module status data Refer to the documentation for each module for details on what the module status contains for a specific module There are 8 words of module status data for each drop The status byte for slot 1 is found in the low byte of the first word
32. al support AnxInit logs messages in its main window These messages are often useful for determining the cause of errors or for technical support To clear the log select Edit ClearLog To copy the contents of the Log to the Windows clipboard so that they can be pasted into another application select Edit Copy A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X MOD Master Page 51 090 0c 1la 90 00 09 PrediId IpAddrstr HostName AN X DHP Ethernet Gateway 192 168 0 9 DHP SerNum 00000009 DaughterID 0006 BootRev ab Stee 000r ConfigRev 1 00 0000 ProdRev 1 00 0000 HwRev Fable Sita b FirmwRev 1 92 9001 Status 9 00000004 VendorId OTS Inc For Help press F1 AN X Log Locating Available AN X Modules To locate all accessible AN X modules on the Ethernet network select Utilities Locate All AN X Modules AnxInit displays a list of the AN X modules it finds showing their MAC IDs IP addresses and host names This command is useful for determining IP addresses when they have been set by a DHCP server or for confirming that an AN X is accessible A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com Page 52 AN X MOD Master November 2011 device s 00000009 Ethernet MAC 00 0c la 00 00 09 192 168 0 41 test
33. and so on 3 Set the RPI for each connection The range is 5 0 ms to 750 ms A product of Quest Technical Solutions RS Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X MOD Master Page 33 E Module Properties AnxMod 0 1756 MODULE 1 1 General Connection Module Info Backplane Requested Packet Interval RPI 10 0 ms 0 2 750 0 ms F Inhibit Module I Major Fault On Controller If Connection Fails while in Run Mode Module Fault Status Offline F j Cancel Help Ensure that any check box that refers to Unicast connections is IMPORTANT unchecked Input Only Connections The AN X MOD Master supports one input only connection from a ControlLogix processor The ControlLogix will be able to read the same input data as the ControlLogix processor with the exclusive owner connection to the AN X MOD Master To configure the input only connection to the AN X MOD Master in RSLogix 5000 1 Right click on the ControlLogix Ethernet module that will be communicating with the AN X and select Add Module Add a 1756 ENBT A module Set the Major Rev to 1 A product of Quest Technical Solutions E ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS Page 34 AN X MOD Master November 2011 E Module Properties ENBT 16 1756 ENBT A 1 1 General
34. anumeric characters and a hyphen To configure the AN X to obtain its IP address from a DHCP server on the network select Obtain an IP address automatically DHCP To configure the AN X to use a static IP address select Use the following Settings and enter e the desired IP address for the AN X e the Subnet mask for the AN X e the default gateway for your network You must enter a default gateway address that is valid for the subnet even if there is no device at the gateway address on the network Click OK to complete the configuration If you click Cancel AN X is left running the boot code Use the Utilities Restart AN X command to restart the AN X in production mode Since you are connecting directly from the computer to AN X use a crossover Ethernet cable The following instructions assume Windows XP They also assume that an Ethernet network card has been installed in the computer and that AnxInit has been installed on the computer The parameters in this example will work when you set up any standalone computer to work with AN X First configure the computer to use a static IP address From the Control Panel select Network Connections Double click on Local Area Connection or whatever connection is being used for the AN X A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com ote a QF PROSOFT PARTNER PROGRAM AN X MOD Master Pa
35. chnology Inc www prosoft technology com AL Saturions AN X MOD Master Page 47 Next it checks the status on drops for each AN X and sets a status bit accordingly Generate OK status for all Drops connected to ANX_A and ANX_B Module by checking for 0 in DropErr words 0 and 1 which are mapped to the first two words on Input Data by default Also Check that AN X is not in Scan Halted State since DropErr table is not valid in this case EQU EQU NEQ ANX_A_Drops_OK Equal Equal Not Equal Source A ANX_A 0 LData 0 Source A ANX_A 0 Data 1 Source A MOD_A_ScanSts 0 0e lt ANX_A 15 1 Data 10 gt Source B 0 Source B 0 0e Source B 3 QU pau NEQ _ ANX_B_Drops_OK Equal Equal Not Equal We i _ Source A ANX_B 0 1 Data 0 Source A ANX_B 0 Data 1 Source A MOD_B_ScanSts 0 0 sANX_B 15 1 Data 10 gt Source B 0 Source B 0 0e Source B 3 It enables scanning on both AN X modules Only the first will scan the network If it detects a duplicate master see below it switches scanners Enable ANX_A scanner if there is no Duplicate Master detected If we have detected duplicate master ANX_A and ANX_B ScanSts in Scan state 2 enable scanning if All drops on ANX_A have good status or Any drops on ANX_B have bad status or We don t have good connections to ANX_B MOD_A_RedundCtl 0 ANX_A_Connections_OK ANX_Dupl_Master lt ANX_A 0 0 Data 0 0 gt c gt ANX_A
36. connected to the AN X In most cases there will be just one Ethernet adapter in the computer The AN X must be on the same subnet as the computer 2 Enter the MAC address of the AN X you are configuring This is printed on the AN X label It consists of six pairs of hexadecimal digits separated by hyphens In the example above it s 00 Oc 1a 00 01 0d If the AN X is already online you can obtain its MAC address using the Utilities Locate All AN X Modules command 3 Enter the IP address you intend the AN X to use Step 2 In step 2 you choose a method of restarting AN X to put it in boot mode A product of Quest Technical Solutions gt os Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS Page 10 AN X MOD Master November 2011 Step 2 Cycle Power or Reboot Command In order to configure the IP address or update the module s firmware the module must be be set to a specific mode There are two ways to do this 1 Cycle power on the AN X Module This is the preferred method but the AN module must be nearby If you choose this option POWER OFF the 4N module and click on the Next button C 2 Send a command on Ethernet that restarts the AN module This method is more convenient if the module is not nearby If you choose this option make sure the AN module is powered ON and fully up and running then click on the Next button lt lt Back
37. e 5 2 Power up the AN X connect it to Ethernet and use 7 AnxInit to assign it an IP address Connect AN X to the Modicon S908 network 4 4 Use the AN X web interface to autoconfigure the 18 Modicon network and ControlLogix configuration 5 Configure the AN X in RSLogix 5000 31 6 Scan I O read inputs and write outputs 7 Use the web interface to create alias tags for 36 RSLogix 5000 8 Import the tags into RSLogix 5000 37 9 Use the tags to access data A product of Quest Technical Solutions 58 gt 2s Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SoLuTIONS AN X MOD Master Page 7 Ethernet Configuration The AN X MOD Master module connects connects a ControlLogix processor to an S908 remote I O network over Ethernet Before you can use the AN X MOD Master you must configure its network properties on Ethernet Ethernet Configuration AN X can be configured to use a static unchanging IP address or it can be configured to obtain its IP address from a DHCP server Unless you have control of the DHCP server in most applications you will want to configure AN X to use a static IP address Otherwise the DHCP server may assign a different IP address each time AN X powers up and any software that accesses the AN X module would have to be reconfigured AN X is shipped with DHCP enabled If it finds a DHCP server on the network
38. ents RedundPrefix ClxName such as diagnostics AL SoLuTIONS TO inputs ClxPrefix DataInput name if present TO outputs ClxPrefix DataOutput name if present Switchover When you turn on the RedundCtl bit for an AN X MOD Master module it waits for 10 ms of silence on the network before it starts scanning as master WARNING If the RedundCtl bits on both AN X modules are on only one acts as master However if the bits are set on both AN X modules and the current master is disconnected from the S908 network even for a very short period the backup takes over If the module that was disconnected comes back online both modules will be master on the 908 network YOUR APPLICATION MUST CHECK FOR THE DUPLICATE MASTER CONDITION AND TAKE APPROPRIATE ACTION A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions AN X MOD Master Page 45 Connect both AN X modules to the S908 network Autoconfigure the primary AN X module Create both remote I O and ControlLogix configuration files Upload the ControlLogix configuration to the computer and edit it Uncomment the RedundEna line and add a prefix that uniquely identifies the AN X e Map RedundCtl to connection 0 The autoconfiguration maps it to outputs to the connection to slot 0 but comments it out e Map RedundSts to the inputs
39. for any connection The autoconfiguration maps it to outputs to the connection to slot 15 but comments it out e Set the ClxPrefix e For each connection add names to the DataInput and DataOutput parameters These names should match the names of the internal ControlLogix arrays that will hold the data e Include the LongInput option if the configuration contains 800 series modules Save the modified file and upload it to the primary AN X Autoconfigure the secondary backup AN X module Create both remote I O and ControlLogix configuration files Upload the ControlLogix configuration to the computer and edit it e Uncomment the RedundEna line and add a prefix that uniquely identifies the AN X e Map RedundCtl to connection 0 The autoconfiguration maps it to outputs to the connection to slot 0 but comments it out e Map RedundSts to the inputs for any connection The autoconfiguration maps it to outputs to the connection to slot 15 but comments it out e Set the ClxPrefix It should match the ClxPrefix for the primary AN X e For each connection add names to the DataInput and DataOutput parameters These names should match the names of the internal ControlLogix arrays that will hold the data and should match the names in the primary AN X e Include the LongInput option if the configuration contains 800 series modules Save the modified file and upload it to the secondary backup A product of Quest Technical Solutions E
40. ge 13 t_ Local Area Connection Status General Support Connection Status Connected Duration 3 days 15 26 18 Speed 100 0 Mbps Activity S a Received ent ecelve Ce Packets 211 924 277 247 Click the Properties button Double click on Internet Protocol TCP IP A product of Quest Technical Solutions gt ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS Page 14 AN X MOD Master November 2011 Internet Protocol TCP IP Properties e T General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 0 10 Subnet mask 255 255 255 0 192 168 0 1 Default gateway id r acare 3U La Use the following DNS server addresses Preferred DNS server Alternate DNS server In this example we assigned the computer an IP address of 192 168 0 10 We set the Subnet mask to 255 255 255 0 standard mask for the Class C network address of 192 168 0 x We set the Default gateway to 192 168 0 1 this address does not exist on the Ethernet network but AN X requires a valid default gateway entry Click OK to accept the settings Connect the compute
41. gs or AN X MOD Ethernet IP ControlLogix Input Only Data Tags To save the file to your computer right click on the link and select Save Target As A product of Quest Technical Solutions 58 gt 2s Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SoLuTIONS AN X MOD Master Page 37 QTS AN X MOD web interface v1 1 5 Microsoft Internet Explorer i File Edit Yiew Favorites Tools Help Q 6 x EEA JO search She Favortes Media O 2 amp B W 3 3 Address E http 4f10 10 0 73 g Google v Psearch web GRBsearch site gS Eh 28blocked Pa options fi A AN X MOD Modicon S908 RIO Configuration Viewing Modicon S908 RIO Configuration Viewing Instructions Configure ControlLogix Support R s anual EAO MENEE View Active Configuration Log Files System Error Log System Info Log ControlLogix Log View All Logs Administration Importing Tags in RSLogix 5000 To import the tags into RSLogix 5000 you must be offline Select Tools Import Tags and import the tag file Tag Format AN X builds the tags from the ControlLogix configuration Each tag is a ControlLogix alias For example ALIAS MOD_d05s4_Out B804 AnxMod 0 0 Data 0 In this example the tag name is MOD_d05s4_Out The name is made up of the ClxPrefix and the tagname from the configuration file If there is more that one word of data for the module AN X ap
42. is an array of 5 INTs that contain information about the current operation of the Modicon 908 network scan Offset Description 0 Scan state O idle no packets being received from the 908 network 1 monitor another master is active 2 scanning 3 scan halted was actively scanning but the enable bit has been turned off 1 Scan counter increments at the start of each S908 network scan A product of Quest Technical Solutions 52 gt e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions Page 44 AN X MOD Master Aliases November 2011 Offset Description 2 Init counter increments whenever a drop on the S908 network is reinitialized 3 current S908 network update time 4 maximum S908 network update time Map ScanSts to input data for any connection By default when you perform an autoconfiguration and create a ControlLogix configuration AN X maps the ScanSts array to the connection to slot 15 but comments out the mapping LongInput 800 series drops send inputs only when the inputs change In redundant applications with 800 series drops include the LongInput parameter in the ControlLogix configuration file to ensure that the backup has the latest inputs The AN X MOD Master creates aliases that can be imported into RSLogix 5000 Item Alias name prefix Base tag Unique elem
43. ith the keyword ConnStatsn where n is the connection number from 0 to 15 in the input section of a connection Examples ConnStats2 40 ConnStats2_ offset 40 A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com ote a Q9 PROSOFT PARTNER PROGRAM AN X MOD Master Page 31 Viewing the Current Configuration To view the ControlLogix configuration currently stored in the AN X start the web interface and select View Active Configuration Click the Ethernet IP link to view the current ControlLogix scheduled data configuration The configuration will be displayed using whatever application is associated with csv files on your computer usually a spreadsheet or text editor Saving the Current Configuration To save the ControlLogix configuration currently stored in the AN X to a file start the web interface and Select View Active Configuration Right click the Ethernet TP link and select Save target to save the current ControlLogix scheduled data configuration to a file Configuring the AN X Module in RSLogix 5000 To configure the AN X MOD Master in RSLogix 5000 1 Right click on the ControlLogix Ethernet bridge module that will be communicating with the AN X and select Add Module Adda 1756 ENBT A module Set the Major Rev to 1 E Module Properties LocalENBT 16 1756 ENBT A 1 1 General Connection Module Info Port Configuratio
44. l file Use the Send button to apply this configuration file Sei Browse Send Home Page Autoconfiguration If you are autoconfiguring the S908 remote I O network make sure the network is connected to the AN X MOD Master To configure just the I O check Auto configure S908 network To configure the remote I O network and also generate a default ControlLogix configuration on the AN X check Auto configure S908 network and ControlLogix configuration Click the Auto configure Network button A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com Page 64 AN X MOD Master November 2011 Manual Configuration Manual configuration does not require that the network be online Create a configuration file Refer to page 24 for details on the file format Browse or type the file name Click the Send File to AN X button to send the values to AN X Configure ControlLogix Support icrosoft Internet Explorer AN X exchanges scheduled data with a ControlLogix processor over Ethernet Refer to section Exchanging Scheduled Data with a ControlLogix on page 24 for information on configuring scheduled data exchange Select Automation Network Configure ControlLogix Support in the web interface to upload the configuration y Log Files v Administration Home Page AN X MOD MAS ControlLogix Configuration Cont
45. ll be enabled so you can move on to the next step If the AN module has been powered ON for more than 10 seconds and the Next button is still disabled press the Back button confirm the MAC and IP addresses and check the Ethernet cabling If the AN X does not enter boot mode within about 10 seconds return to the previous screens and check the entries The AN X TCP IP Configuration dialog appears AN X TCP IP Configuration Enter the IP configuration you want the previously selected AN module to use You MUST enter a valid Default gateway IP address that is on the same subnet as the AN module but you don t need to have a device at that address Host Name Obtain an IP address automatically DHCP Use the following Settings IP Address 192 168 0 105 Subnet mask 255 255 255 0 Default gateway 192 168 O0 1 Enter a Host Name for the AN X AN X uses this name when it creates tags so give the AN X a meaningful name that is unique on your A product of Quest Technical Solutions a ei Sold and Supported by ProSoft Technology Inc PROSOET www prosoft technology com PARTNER PROGRAM AL SOLUTIONS Page 12 AN X MOD Master Standalone Computer TIP AL SoLuTIONS November 2011 network This name is also used internally by AN X and may be used to identify the AN X if you have a DNS server on your network The name can be from 1 to 31 characters long It can contain alph
46. n Port Diagnostics Backplane Type 1756 ENBT 4 1756 10 100 Mbps Ethernet Bridge Twisted Pair Media Vendor Allen Bradley Parent LocalENBT ieee nma o Address Host Name Description 192 168 0 105 C Host Name Comm Format Ni x Slot fie a Chassis Size fiz a Revision po Electronic Keying Disable Keying Status Offline Cancel Help Enter the Name This is usually the host name you assigned to AN X when you configured its IP properties A product of Quest Technical Solutions Be ei Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS Page 32 AN X MOD Master November 2011 Set the Slot to 16 Set the chassis size to 17 Set the Comm Format to None Set the IP address to match the AN X module Set Electronic Keying to Disable Keying Record the Name as it is used to create tags to access the data 2 Add Generic modules for each required connection E Module Properties AnxMod 0 1756 MODULE 1 1 General Connection Module Info Backplane Type 1756 MODULE Generic 1756 Module Parent AnxMod r Connection Parameters Assembly Instance Size Name AnwSlot0 Input 250 4 16 bit Description Output 16 bit Configuration 8 bit Comm Format Data Slot Status Offline Set the parameters as shown Set the Slot to O for the first connection 1 for the second connection
47. n on how to upload the configuration from AN X and save it to a file Manual configuration is useful when the Modicon network is not attached to the AN X or when you need a configuration different from the default Create the configuration file using a text editor or a spreadsheet such as Excel and save it as a comma separated variable CSV file with extension csv The file format is described on page 21 To send the configuration to AN X 1 From the AN X web interface select Automation Network S908 I O Network Configuration 2 Type or browse the configuration file name into the Select file area 3 Click the Send To AN X button to send the file to AN X AN X parses the file and shows either the current configuration if the configuration was sent successfully or an error message if there was a problem with the file e re nt A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com os K PROSOFT PARTNER PROGRAM AN X MOD Master Page 21 Configuration File Format The I O configuration file defines the contents of the drops to be scanned and some parameter data It is a comma separated variable csv text file which can be created with a text editor or with a spreadsheet such as Excel The file defines the contents of the drops on the S908 network Begin a drop definition with a line that consists of the keyword Drop followed by an e
48. nd click Open Look in a anxdesnet x e FE a anxamxdes v1 4 3 bin anxamxdes v1 4 4 bin File name anxamxdes v1 4 4 bin Files of type fats Firmware File bin 7 Cancel I Open as read only i AnxInit transfers the firmware file and restarts the AN X After you run update the firmware you must reconfigure the AN X A product of Quest Technical Solutions a e Sold and Supported by ProSoft Technology Inc PROSOEFET www prosoft technology com PARTNER PROGRAM Page 60 AN X MOD Master November 2011 Update Firmware Command The Utilities Update Firmware command updates all the firmware on an AN X you have previously selected using the Utilities Select An AN X command This command resets the AN X You will receive a warning and be given the opportunity to Cancel the command If you cancel at the filename dialog the AN X has already been reset and is in configuration mode Use the Utilities Restart AN X command to restart it in production mode Click the Next gt gt button and select the firmware file you want to download and click Open Look in E anxdesnet gt ae a anxamxdes v1 4 3 bin a anxamxdes 1 4 4 bin File name anxamxdes v1 4 4 bin Files of type fats Firmware File bin Cancel J Open as read only Anxlnit transfers the firmware file and restarts the AN X After you run update the firmware you must reconfigure the AN X
49. nd installation The module has a standard F connector for connection to the S908 remote I O network AN X should be connected like any other node Ensure that the physical ends of the S908 remote I O network are properly terminated The AN X module does not connect the 908 cable to earth ground If a connection to ground is required use an F connector grounding block A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SoLuTIONS AN X MOD Master Page 5 Ethernet Cabling AN X has a standard RJ 45 connector for connecting to Ethernet If you are connecting AN X to an existing network through a router or switch use a standard Ethernet cable If you are connecting directly between a computer and AN X use a crossover cable Software Installation You must uninstall any previous version of the software before you can install a new version Use the Windows Control Panel Add and Remove Programs to remove the old version Insert the CD supplied with the AN X module and run the program setup exe on the CD A product of Quest Technical Solutions ee Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions Page 6 AN X MOD Master November 2011 Quick Start Step See page 1 Install the AN X Windows softwar
50. not scan the network You can override this behaviour by including a line with the keyword ScanModProg in the configuration file This causes the AN X MOD Master module to continue to communicate with the S908 network when the ControlLogix processor is in program mode Similarly ControlLogix processors with exclusive owner connections to other AN X slots will also update If the exclusive owner connection to slot 0 stops AN X stops all communication with the S908 network This option is included for debugging since it allows inputs to update in the ControlLogix It is NOT recommended for normal operation For maximum compatibility with Modicon hardware it should not be used in normal operation In addition to the I O data there are other items that can be mapped to connection input data For all these items you can assign an offset for the data within the ControlLogix input data or your can leave out the offset and let AN X assign the offset automatically A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com Page 28 AN X MOD Master TIP AL SoLuTIONS November 2011 All items are of the form offset optional ItemKeyword If you create the ControlLogix configuration automatically when you autoconfigure the S908 network these items are mapped by default to ClxSlot 15 If you map the diagnostic data to a separate connection use a long RPI
51. nt Configuration 31 Saving the Current Configuration 31 Configuring the AN X Module in RSLogix 5000 31 Input Only Connections 33 ControlLogix Alias Tags 36 Using the ControlLogix Log 38 REDUNDANCY 40 Controller Redundancy 40 Scanner Redundancy 40 Cabling 40 ControlLogix Ethernet Configuration File 42 Aliases 44 USING ANXINIT 50 Anxinit Log 50 Locating Available AN X Modules 51 Selecting an AN X 52 Set AN X IP Configuration 53 Restart an AN X 54 AN X Info 54 Read Kernel Parameters 55 Run Config Mode 55 Update AN X Flash 56 Update Firmware 56 Firmware Update Wizard 56 Update Firmware Command 60 Patch Firmware 60 USING THE WEB INTERFACE 62 A product of Quest Technical Solutions EN o Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM 908 I O Network Configure ControlLogix Support View Configuration Files View Active Configuration Log Files System Error Log System Info Log ControlLogix Log View All Logs Administration Menu Browse File System AN X IP Configuration Archive Configuration TROUBLESHOOTING LEDs Ethernet LEDs SYS LED NET LED Network Status UPDATING THE FIRMWARE Reading Version Numbers SPECIFICATIONS SUPPORT WARRANTY 63 64 65 70 70 70 70 71 72 72 73 74 75 AN X MOD Master Module Overview The AN X MOD Master communications module connects a ControlLogix PLC or other device to a Modicon S908
52. o Contact Us Sales and Support Sales and Technical Support for this product are provided by ProSoft Technology Contact our worldwide Sales or Technical Support teams directly by phone or email Asia Pacific 603 7724 2080 asiapc prosoft technology com Europe Middle East Africa 33 0 5 34 36 87 20 Europe prosoft technology com North America 1 661 716 5100 support prosoft technology com Latin America Sales only 1 281 298 9109 latinam prosoft technology com A product of Quest Technical Solutions 58 gt 2s Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X MOD Master Page 75 Warranty Quest Technical Solutions warrants its products to be free from defects in workmanship or material under normal use and service for three years after date of shipment Quest Technical Solutions will repair or replace without charge any equipment found to be defective during the warranty period Final determination of the nature and responsibility for defective or damaged equipment will be made by Quest Technical Solutions personnel All warranties hereunder are contingent upon proper use in the application for which the product was intended and do not cover products which have been modified or repaired without Quest Technical Solutions approval or which have been subjected to accident improper maintenance installation or application or on
53. ontrolLogix A Modicon S908 remote I O network can contain up to 2048 words of input data and 2048 words of output data 32 drops x 64 words per drop Each scheduled connection with a ControlLogix contains at most 250 words of input data and 248 words of output data In order to be able to scan the largest possible Modicon network the AN X MOD Master module supports multiple scheduled connections with a ControlLogix processor over Ethernet The AN X MOD Master module behaves like a 17 slot ControlLogix rack with an ENBT A module in slot 16 and generic modules in slots 0 to 15 A ControlLogix processor can open scheduled connections to each of these 16 generic modules Each scheduled connection consists of up to 248 words of output data from the ControlLogix processor to the AN X and up to 250 word of input data from the AN X to the ControlLogix processor Each connection can have its own RPI from 5 to 750 ms In general you should try to keep the number of connections small There is significant overhead in opening and maintaining each connection You map the inputs and outputs for the Modicon I O modules on the S908 network to the data for these scheduled connections AN X can create the mappings automatically or you can create a mapping configuration manually You can have AN X create the mapping file automatically then edit the file to better suit your application For example in order to make the most efficient use of the
54. or to connect to the S908 network AN X MOD Master module CD containing software and documentation rubber feet for desktop use There are three AN X modes of operation Boot mode The AN X is running its low level startup firmware Configuration mode This is the mode when you are updating the firmware in the AN X Production mode This is the normal runtime mode of operation A product of Quest Technical Solutions gt 25 Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 4 AN X MOD Master November 2011 Installation Prevent Electrostatic Discharge The module is sensitive to electrostatic discharge WARNING Electrostatic discharge can damage integrated circuits or semiconductors Follow these guidelines when you handle the module e Touch a grounded object to discharge static potential e Do not touch the connector pins Power AN X requires a DC power input of anywhere from 12 to 24 VDC 1 2 3 na GND Left to right the pins on the power connector are chassis ground negative voltage and positive voltage The chassis ground should be connected Power consumption is 200 mA 12VDC or 100 mA 24VDC The part number for the power connector is Phoenix MSTB 2 5 3 ST 5 08 908 Cabling and Termination Refer to the Modicon Remote I O Cable System Planning and Installation Guide 890 USE 101 00 Version 3 0 for detailed information on cabling a
55. oth AN X modules Outputs go to ANX_A and ANX_B COP 9 Copy File t _ Source ANX_Output_0 1 Dest ANX_A 0 0 Data 1 Length 247 OP Copy File Source ANX_Output_0 1 Dest ANX_B 0 0 Data 1 Length 247 Duplicate master detection Detect duplicate masters by checking for ANX_A ScanSts and ANX_B ScanSts in Scan mode 2 This usually happens if the S908 network cable to one of the AN X modules is disconneted or cut ANX_A_Connections_OK QU ANX_B_Connections_OK EQU ANX_Dupl_Master 10 Equal JE Equal k Source A MOD_A_ScanSts Source A MOD_B_ScanSts lt ANX_A 15 LData 10 lt ANX_B 15 1 Data 1 0 0 04 Source B 2 Source B 2 Reset Duplicate Master detection when connection is closed to one of the AN X modules This is done by 1 Inhibiting the connection 2 Cyling power to the AN X module 3 Disconnecting the Ethernet cable to the AN X module ANX_A_Connections_OK ANX_Dupl_Master 1 m U gt ANX_B_Connections_OK u wa Other factors to consider Do not use the ScanModProg parameter if you are using redundancy When you modify the ControlLogix configuration file and add elements the mapped data may become larger than the maximum for a connection especially for large I O networks or for networks with many analog modules It may be necessary to change some of the mappings Also A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL Saturion
56. pends an underscore and a number to the tagname for example ALIAS MOD_d05r4s4_Inp_0 B863 AnxMod 0 1 Data 8 ALIAS MOD_d05r4s4_Inp_1 B863 AnxMod 0 1 Data 9 ALIAS MOD_d05r4s4_Inp_2 B863 AnxMod 0 1 Data 10 ALIAS MOD_d05r4s4_Inp_3 B863 AnxMod 0 1 Data 11 The address is AnxMod 0 0 Data 0 The address is made up of the ClxName and the data location A product of Quest Technical Solutions gt Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 38 AN X MOD Master November 2011 Using the ControlLogix Log If there are problems with scheduled connections to the AN X use the ControlLogix log to identify the cause From the web interface select Log Files ControlLogix Log to display the log Look for error messages that describe in detail the cause of any problem with the current configuration e e SG o os A product of Quest Technical Solutions Sold and Supported by K ProSoft Technology Inc www prosoft technology com PROSOFT PARTNER PROGRAM AL SoLuTIONS AN X MOD Master Page 39 A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com PROSOFT PARTNER PROGRAM Quest Tecunjcat Solutions Page 40 AN X MOD Master November 2011 Redundancy Controller Redundancy For redundant controller ap
57. plications use the ControlLogix 1756 RM redundancy modules They can also be used with two AN X modules in redundant scanner applications Scanner Redundancy Version 2 2 1 and above of the firmware for the AN X MOD Master includes features to implement redundant I O scanners using two AN X MOD modules One AN X is designated the primary and acts as the scanner the other is designated the secondary and acts as a backup If the primary AN X goes offline the backup takes over The backup AN X constantly monitors the S908 network When it becomes the primary it has the current state of inputs drop status etc Each ControlLogix processor has access to current I O data from the S908 network The backup AN X listens to the S908 network and waits for 10 ms of silence on the network before it takes over It does not start scanning if it hears another master already online The ControlLogix configuration file must be modified to support redundancy No changes are required to the S908 I O Configuration file Cabling Using the Modicon Redundancy Terminator Kit You can use the Modicon Redundancy Terminator Kit to connect to the S908 network The AN X module has built in termination Do not use the inline terminators in the cable from the AN X module to the splitter from the kit Do not disconnect either AN X module from the splitter since that also removes the termination A product of Quest Technical Solutions
58. quals sign and then the drop number from 1 to 32 There should be no spaces before or after the equals sign Example Drop 7 End the drop definition with a line with just the keyword EndDrop Between the Drop and EndDrop lines enter the rack and slot definitions for the drop Begin a rack definition with a line that consists of the keyword Rack followed by an equals sign and then the rack number from 1 to 5 There should be no spaces before or after the equals sign Example Rack 1 After the rack definition enter the slot definitions They consist of the keyword Slot followed by an equals sign and the slot number a comma then the keyword Type an equals sign and the module type There should be no spaces before or after the equals signs Examples Slot 4 Type B804 Slot 7 Type ACI_030_00 For rack 1 the rack definition line can be omitted It is required for racks 2 to 5 If there is no explicit Rack definition entry AN X assumes the following slot definitions are for rack 1 There is no EndRack command If there is more than one rack in a drop just start the new rack with a Rack definition Anything after a semicolon on a line is treated as a comment Comments can be inserted at the end of a line or on a separate line Quantum Parameter Data Some Quantum modules have additional parameters to define configurable properties of the module You can send this parameter data by adding a line after the slot definition
59. r to AN X using the crossover cable If this is the first time you have used the AN X module it will look for a DHCP server on the network It waits about three minutes then reverts to a default IP address of 192 168 0 41 Power up the AN X and wait for the search for a DHCP server to time out When the search for a DHCP server times out AN X repeatedly flashes the SYS LED red three times followed by a pause Run AnxInit Select Utilities Locate All AN X Modules and confirm that it finds the AN X A product of Quest Technical Solutions Bd e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL SOLUTIONS AN X MOD Master Page 15 I Local Area Connection 2 0x2 00 Oc 1a 00 01 0d 192 168 0 105 Anxinit DBR Configuration Utilities Edit view Help Found 1 AN X device s 0000010d Ethernet MAC 00 0c 1a8 00 01 0d abel abfevzt 0 chil AnxMod For Help press F1 Select Utilities Select An AN X and enter the MAC Address and IP address Set Ethernet amp IP Address Adapter Local Area Connection 2 X Ethernet MAC Address 00 0c 1 a 00 01 0d IP ddress 192 168 0 4 Cancel Click OK to accept the setting Select Utilities AN X IP Configuration A product of Quest Technical Solutions E ei Sold and Supported by ProSoft Technology Inc PROSOET www prosoft technology com PARTNER PROGRAM AL SOLUTIONS Page 16 AN X MOD Master
60. ration Menu is used to set the AN X IP address and to view and edit files on AN X The file edit function is password protected and is used only for AN X technical support If you are required by technical support to examine files on the AN X select Administration Browse File System A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM Page 68 AN X MOD Master November 2011 E QTS AN X MOD MAS web interface v2 1 5 Microsoft Internet Explorer EJE File Edit view Favorites Tools Help a Google G Search Gee ge E 2340blocked Autolink Ral Options Links Om O DAG Doe dome O 8B A MB eens B i Address http 4 192 168 0 105 Sai aco Restricted Access Automation Network Log Files v Administration Technical support will provide the password and supply detailed information on any further steps AN X IP Configuration You can change the AN X IP configuration from the web interface This requires that you know the currect IP address and can use it to access the web interface Select Administration AN X IP Configuration A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AN X MOD Master Page 69 QTS AN X MOD MAS web interface v2 1 5 Microsoft Internet Explo
61. remote I O network over Ethernet The module acts as a scanner on the 908 network reading inputs and writing outputs The module supports 800 series and Quantum remote drops It supports up to 32 drops The module supports up to 16 scheduled connections with a ControlLogix processor over Ethernet so the ControlLogix processor can read inputs from the Modicon network and write outputs The AN X MOD Master module has a web interface for configuration You can communicate with the module using any standard web browser such as Internet Explorer A watchdog timer is implemented in the module s hardware If the firmware does not kick the watchdog within the timeout period the watchdog times out and places the module into a safe fatal failure state A jabber inhibit timer is implemented in the module s hardware If the network transmitter is on longer than 150 of the longest network frame time the transmitter is forced off and the module is placed into a safe fatal failure state AN X MOD Master Page 3 The module firmware can be updated over Ethernet using the Windows utility supplied Refer to page 72 for details Hardware Features Package Contents Modes of Operation 10 100 Network The module has LEDs to indicate the status of the Ethernet connection the module s internal state and state of the connection to the 908 remote I O network e an Ethernet connector a power connector e an F connect
62. rer elk i File Edit Yiew Favorites Tools Help ay Google v C search Ge ef g 2340 blocked Autolink Ral Options i Links O O DAG Lave kens OL M DUS fromme B address httpy 192 168 0 105 00000 o l _ Ee Automation Network AN X IP Configuration Log Files v Administration DHCP Static AN X Hostname AN X IP Address NET Mask Gateway Address You can configure the AN X to use DHCP or to use a static IP address The host name can contain alphanumeric characters and a hyphen Click SUBMIT to set the parameters When prompted click CONTINUE to reboot the AN X with the new parameters Archive Configuration You can archive all the current AN X configuration files and log files from the web interface The archive file is a standard gzip compressed tar archive Select Administration Archive configuration Click on the Archive File link and save the file Select the destination where the file will be stored A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com ICAL SOLUTIONS Page 70 AN X MOD Master November 2011 Troubleshooting LEDs The AN X MOD Master has LEDs that indicate the state of the Ethernet connection the overall module state and the connection to S908 remote I O network Ethernet LEDs There are two LEDs that indicate the state of the Ethernet connection The orange
63. rolLogix Scheduled Data Configuration Instructions The ControlLogix scheduled data communications feature of the AN X MOD MAS device is configured using a csv file comma delimited file format exported by programs like Microsoft s Excel Create a ControlLogix scheduled data communication configuration using Excel and save that file in csv format To apply this configuration to this AN X MOD MAS device use the form below to select the local file Use the Send To AN X button to apply this configuration file ct O Type or browse the configuration file name into the Select file area Then click the Send To AN X button to send the file to AN X A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com CAL SOLUTIONS AN X MOD Master Page 65 Check the ControlLogix Log to determine if there have been any errors with the upload View Configuration Files Select View Configuration Files to view the S908 and ControlLogix configuration files 12 Microsoft Internet Explorer AN X MOD MAS Modicon 908 RIO Configuration Viewing Modicon 908 RIO Configuration Viewing Instructions The AN X MOD MAS device is configured using a csv file see us nanual for details A link to this file is provided below Left clicking this link displays the AN X MOD MAS configuration file using the application that your web browser associates with csv files Microsoft Excel a
64. s AN X MOD Master Page 49 when you add elements the offsets in the comments generated by the autoconfiguration will no longer be correct Make sure the mappings in the ControlLogix configurations in both AN X modules are the same Each AN X module cannot check the configuration in the other AN X module LEDs When the AN X MOD Master is used in redundant mode the network LED is green when scanning orange when monitoring and red when there has been an error or during switchover A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL Solutions Page 50 AN X MOD Master Anxlnit Log AL SoLuTIONS November 2011 Using Anxlinit AnxInit is a 32 bit Windows application supplied with AN X to perform the following functions e Locate and identify AN X modules on the Ethernet network e Select a specific AN X for configuration e Set the IP address and other network parameters for an AN X e Restart an AN X in production mode e Display information about the selected AN X e Read the kernel parameters for the selected AN X e Update the flash low level firmware on the selected AN X e Update the firmware on the selected AN X e Patch the firmware on the selected AN X In addition it can be used to e clear the AnxInit log copy the contents of the log to the clipboard for use by another application This is often useful for technic
65. s Restart AN X command to restart AN X in production mode A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com at Sovvriows Page 56 AN X MOD Master Update AN X Flash Update Firmware Firmware Update Wizard AL Solutions November 2011 The Utilities Update AN X Flash command updates the low level firmware configuration and production kernels Files have extension qtf This command resets the AN X You will receive a warning and be given the opportunity to Cancel the command If you cancel at the filename dialog the AN X has already been reset and is in boot mode Use the Utilities Restart AN X command to restart it in production mode Look in Sa downloads gt e FA 38 ANXBOOT QTF AnxBoot_1_2_1 qtf zImage cfg 1 00 0001 qtf a zImage cfg v1 00 0002 qtf zImage cfg v1 00 0003 qtf a zImage cfg 1 00 0005 qtf File name Files of type jats Flash File Qtf Cancel J Open as read only 4 There are two ways to update all the firmware in an AN X module 1 The Configuration Firmware Update command starts the firmware update wizard which takes you step by step through the firmware update process 2 The Utilities Update Firmware command updates all the firmware on an AN X you have selected using the Utilities Select An AN X command Firmware files have extension bin
66. s to import into RSLogix 5000 Example To associate ControlLogix offset 27 with the Modicon module at address drop 4 rack 2 slot 4 and assign it tagname tag 27 d4r2s4 tag1 Example To map the Modicon module at address drop 14 rack 1 slot 3 to the next available ControlLogix location and assign it tagname tag2 d14r1s3 tag2 or since the rack number is 1 you can also use d14s3 tag2 e re nt A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com gt NS PROSOFT PARTNER PROGRAM WARNING Other Mappable Data AL Solutions AN X MOD Master Page 27 Example Configuration File ClxName ANX ClxPrefix MOD_ ClxSlot 0 DataOutput d4s4 Drop4Slot4Outputs Datalnput d4s7 Drop4Slot7 Inputs Program Mode Behaviour Option The ControlLogix processor that is the exclusive owner of the connection in slot 0 controls how the AN X MOD Master module scans the S908 network For that reason when you map the data you must always include a connection to the generic module in slot 0 When the ControlLogix processor with the exclusive owner connection to slot 0 on the AN X is in program mode or the connection is stopped the AN X stops scanning the S908 network just as a Modicon scanner would Even if other ControlLogix processors have exclusive owner connections to other slots on the AN X and are in run mode AN X does
67. selected AN X Set AN X IP Configuration Utilities AN X IP Configuration sets the AN X IP address and hostname The AN X must be on the local Ethernet to set its IP address First select the AN X using the Utilities Select An AN X command Next select Utilities AN X IP Configuration The AN X TCP IP Configuration dialog appears AN X TCP IP Configuration xi Enter the IP configuration you want the previously selected AN module to use You MUST enter a valid Default gateway IP address that is on the same subnet as the AN module but you don t need to have a device at that address Host Name JER RUE Obtain an IP address automatically DHCP Use the following Settings IP Address 192 168 0 10 Subnet mask 255 255 255 0 Default gateway 192 168 O 1 Cancel Enter a Host Name for the AN X AN X uses the host name to create ControlLogix tags so give the AN X a meaningful host name This name is used internally by AN X and may be used to identify the AN X if you have a DNS server on your network The name can be from 1 to 31 characters long To configure the AN X to obtain its IP address from a DHCP server on the network select Obtain an IP address automatically DHCP To configure the AN X to use a static IP address select Use the following Settings and enter the following e the desired IP address for the AN X e the Subnet mask for the AN X e the default gateway for your network
68. t 4 Type DAI_353_00 Slot 7 Type DAO_840_00 e re nt A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com os K PROSOFT PARTNER PROGRAM AN X MOD Master Page 23 EndDrop Viewing the Current Configuration To view the S908 remote I O configuration currently in AN X access the web interface and select Automation Network View Active Configuration You can also view the configuration file by accessing the web interface and selecting Automation Network View Configuration Files Click on the AN X MOD MAS S908 Network Configuration File link and select Open to open the file in whatever application is associated with CSV files on your computer usually a spreadsheet or a text editor Saving the Current Configuration To save the configuration currently in AN X to a file access the web interface and select Automation Network View Configuration Files Right click on the AN X MOD S908 Network Configuration File link and save the file Supported Modicon Modules To view a list of supported modules view the current configuration AN X appends a list of supported modules to the end of the file A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions Page 24 AN X MOD Master November 2011 Exchanging Scheduled Data with a C
69. tails Occasionally individual patch files are released They have extension pch and are downloaded using the Utilities Patch Firmware command in AnxInit Refer to page 60 for details Reading Version Numbers To read the version numbers of the various software components Boot code AnxInit AN X Info Configuration kernel AnxInit AN X Info Production kernel AnxInit AN X Info Firmware AnxInit AN X Info version depends on current mode boot configuration or production Individual applications Web interface System Info Log AL SoLuTIONS A product of Quest Technical Solutions E es Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X MOD Master Page 73 Specifications Parameter Specification Function Bridge between Ethernet and Modicon S908 remote I O network Typical Power 200 mA 12 VDC or 100 mA 24 VDC Consumption Maximum Power 2 4W dissipation Environmental Conditions Operational 0 50 C 32 122 F Temperature Storage Temperature 40 to 85 C 40 to 185 F Relative Humidity 5 95 without condensation A product of Quest Technical Solutions E Sold and Supported by if ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM wren Solutions Page 74 AN X MOD Master AL SoLuTIONS November 2011 Support How t
70. tartup the SYS LED sequence is e boot code starts fast flashing red boot code loads a kernel solid red e if the configuration kernel is loaded 2 red flashes followed by a pause e if the production kernel loads with no errors solid green NET LED Network Status The NET LED indicates the status of the S908 remote I O network connection Solid green All configured drops are responding Some modules may be in error Yellow No configured Modicon I O Flashing or Network error solid red A product of Quest Technical Solutions E e Sold and Supported by ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AL Solutions Page 72 AN X MOD Master November 2011 Updating the Firmware The AN X operating software consists of several parts boot code runs at startup configuration kernel runs when you update firmware e production kernel runs in normal operation e application software for network communication and scheduled messaging The kernels are supplied in file with extension qtf and are updated using the AnxInit utility Run the command Utilities Update AN X Flash and select the file you wish to download Refer to page 56 for details Firmware files contain the application programs for AN X and have extension bin They are downloaded using the command Configuration Firmware Update or Utilities Update Firmware in AnxInit Refer to page 56 for de
71. text editor etc Right click the links below to save the target to your local computer AN X MOD MAS 5908 Network Configuration File v Log Files OD MAS ControlLogix Confi AN X MOD MAS Ethernet IP Tagname Files Y Administration The AN X MOD MAS device creates several tagname files from the device s active configuration These files are intended to be used with ControlLogix programming software and or other Ethernet IP clients A link to these files is provided below Left clicking a link will display the AN X MOD MAS configuration file using the application that your web browser associates with csv files Microsoft Excel a text editor etc Right click the links below to save the target to your local computer gt Click on the links to view the files using the application that is associated with CSV files Right click on the links to retrieve the files from AN X and store them on your computer View Active Configuration Select View Active Configuration to view the S908 remote I O or ControlLogix configuration file in the web browser A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com ICAL 1 SOLUTIONS Page 66 AN X MOD Master November 2011 Z QTS AN X MOD MAS web interface v1 1 12 Microsoft Internet Explorer File Edt View Favorites Tools Help 7 a Bak gt OA A Aseh airavertes Greda D 4 aA Sl Address http j 192 168 0 9 z
72. ts on every scan DataOutput arrayname The array names can be used to creates aliases for the internal ControlLogix arrays used for the data for the connection and should be the same for AL Solutions A product of Quest Technical Solutions Sold and Supported by F 3 ProSoft Technology Inc PROSOFT www prosoft technology com PARTNER PROGRAM AN X MOD Master Page 43 Parameter Description DatalInput both AN X modules arraynamename ClxName ClxName is used in the address part of the aliases for elements that are unique for each AN X such as diagnostics It is usually set equal to the Ethernet host name ClxPrefix The ClxPrefix is used in the alias name for I O data It should be the same for both AN X modules in a redundant application RedundEna Include a line with the RedundEna parameter followed by a comma and a unique name for the AN X at the start of the ControlLogix configuration file RedundPrefix AN X uses the RedundPrefix when it generates aliases for elements that are unique to each AN X module such as diagnostics RedundCtl RedundCtl consists of a single 16 bit word Only bit 0 is used To enable an AN X to act as the scanner set bit 0 to 1 To disable the AN X set bit 0 to 0 Map RedundCtl to the output data for the connection to slot 0 in each AN X If the configuration file contains RedundEna you must map RedundCtl ScanSts ScanSts
73. which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables nor to any damage resulting from battery leakage In all cases Quest Technical Solutions responsibility and liability under this warranty shall be limited to the cost of the equipment The purchaser must obtain shipping instructions for the prepaid return of any item under this Warranty provision and compliance with such instruction shall be a condition of this warranty Except for the express warranty stated above Quest Technical Solutions disclaims all warranties with regard to the products sold hereunder including all implied warranties of merchantability and fitness and the express warranties stated herein are in lieu of all obligations or liabilities on the part of Quest Technical Solutions for damages including but not limited to consequential damages arising out of or in connection with the use or performance of the Product A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL Solutions
74. y damage or economic loss These warnings help to WARNING e identify a hazard e avoid the hazard e recognize the consequences Identifies information that is especially important for successful application and understanding of the product IMPORTANT Identifies information that explains the best way to use the AN X MOD TE Master Microsoft is a registered trademark of Microsoft Corporation Windows Windows XP Windows Vista and Windows 7 are trademarks of Microsoft Corporation ControlLogix RSLinx and RSLogix 5000 are trademarks of the Allen Bradley Company Inc A product of Quest Technical Solutions Sold and Supported by ProSoft Technology Inc www prosoft technology com AL SoLuTIONS AN X MOD MASTER MODULE OVERVIEW Hardware Features Package Contents Modes of Operation INSTALLATION Prevent Electrostatic Discharge Power 908 Cabling and Termination Ethernet Cabling Software Installation QUICK START ETHERNET CONFIGURATION Ethernet Configuration Standalone Computer Reconfiguring an AN X from an Unknown State 908 NETWORK CONFIGURATION Autoconfiguration Manual Configuration Configuration File Format Viewing the Current Configuration Saving the Current Configuration Supported Modicon Modules EXCHANGING SCHEDULED DATA WITH A CONTROLLOGIX Mapping I O Data 20 21 23 23 23 24 24 Page 4 AN X MOD Master November 2011 Other Mappable Data 27 Viewing the Curre