Home

User Manual - CO2Meter.com

image

Contents

1. e 1 10 foot length 1 8 tubing e 2 1 8 Barb tubing bulkhead fitting e 2 1 8 Barb 10 32 fittings snow ane ER e 2 Particle Filter CM 0118 e 2 Hydrophobic Filter CM 0117 e 2 Moisture Trap CM 0112 Optional Accessories If not included you can purchase an Extreme Moisture Filter separately These filters are ideal for high humidity environments to allow air flow while keeping humidity out Use in anywhere humidity is very high gt 95 SKU CM 0103 Rev 1 3 Aug 2014 Pg 6 of 23 Sample Draw Data Logger Manual CO2Meter com GasLab Software Visit CO2Meter com and go to the Downloads page see link below to download our GasLab software free or for more information on how to connect configure and calibrate your meter For general information about the program please see the GasLab User Instruction Manual included with your meter sensor Additional copies of the GasLab user manual is available at http www co2meter com pages downloads IMPORTANT MAKE SURE TO INSTALL SOFTWARE BEFORE CONNECTING YOUR DEVICE TO YOUR COMPUTER By installing our GasLab software first you will ensure that the proper driver necessary for your unit is installed on your computer before connecting your meter Click on the Install Now link and then select Run when prompted by your browser as shown on Figure 1 below Minimum System Requirements To utilize our free software your computer mu
2. T CO2Meter com Indoor Air Quality Products User Manual CO2 Sampling Data Logger CO2 Sample Draw Meter SAMPLING DATALOGGER inn N Models Covered CM 0001 CM 0051 CM 0002 CM 0004 CM 0006 CM 0056 CM 0003 CM 0005 CM 0050 CM 0057 Copyright 2014 CO2 Meter All Rights Reserved Sample Draw Data Logger Manual CO2Meter com Rev 1 3 Aug 2014 Pg 2 of 23 sample Draw Data Logger Manual Table of Contents MODELS COVERED ccssssscccsssccccsssccccssceesesseeens WELCOME serroestaessiecadscrivondecitenadvancasaivecdeandseceradeccue IMPORTANT SAFEGUARDS sscecsscsceccscsceccees PACKAGE CONTENTS wcsssicssssatcrvscnscicesanesasvansstecnieass OPTIONAL ACCESSORIES scvaistancctcssianstentsrccieghotarsiteatubedt GASLAB SOFTWARE rinrin MINIMUM SYSTEM REQUIREMENTS sssssssssssssseseerssssssees PRODUCT OVERVIEW ccccsccceccsccsccceccseceesenee POWERING THE UNIT sacusssnsdcicesnnsatensiasstengoantdnediovasanceaas LCD DISPLAY IF APPLICABLE scccccceeeeeeeeeeeseeseseeees USAGE PUMP ONLY scccccccsssecccseesesscseeeeeeseseeens THEORY OF OPERATION cecceceecsecscceccececseesececeeceeeas CAUBRATION scrissero a E aa CALIBRATION PROCEDURE cscseceesseceecececeeeseeeceeceees DEVICE SPECIFICATIONS ssscccsseseccscseecceseeees TROUBLESHOOTING GUIDE siincusensssnessndeanneonsaconsisesedaieant SUPPOR T ssccsssecnsncstorssascanscstsecesssssuanatsbeasara
3. V 410 20 5A For more troubleshooting tips on GasLab software see GasLab manual located at www co2meter com pages downloads Support The quickest way to obtain technical support is via email Please send all support enquires to support co2meter com In your email please include a clear concise definition of the problem and any relevant troubleshooting information or steps taken so far so we can duplicate the problem and quickly respond to your inquiry Rev 1 3 Aug 2014 Pg 19 of 23 sample Draw Data Logger Manual CO2Meter com Warranty This unit comes with a 1YEAR warranty period limited manufacturer s warranty starting from the date the unit was shipped to the buyer During this period of time CO2Meter com warrants our products to be free from defects in materials and workmanship when used for their intended purpose and agrees to fix or replace at our discretion any part or product that fails under normal use To take advantage of this warranty the product must be returned to CO2Meter com at your expense If after examination we determine the product is defective we will repair or replace it at no additional cost to you This warranty does not cover any products that have been subjected to misuse neglect accident modifications or repairs by you or by a third party No employee or reseller of CO2Meter com s products may alter this warranty verbally or in writing Returns If the product fai
4. ation to initialize and set the logging period and real time clock Insert four 4 AA size batteries into this unit or connect the unit to the included power supply In order to initialize data logging functionality the unit MUST be connected to the computer with data logging switched to off and the GasLab software started Once the unit has been connected click on the Configure Sensor button in the GasLab interface set the data logging interval and pump periods as desired We recommend leaving the pump interval to the default 10 second period For the pump period we recommend 10 or more seconds Error Reference source not found Error Reference source not found shows the available settings The pump PWM period can also be tweaked for advanced applications with 1 being full duty cycle and values approaching 255 being the Rev 1 3 Aug 2014 Pg 10 of 23 sample Draw Data Logger Manual CO2Meter com shortest duty cycle The pump mode should always be set to Data logging for proper operation of the unit All models have an internal coin cell CR 2032 3V battery backup for the real time clock This battery is inserted in the factory for your convenience and should last the lifetime of the product Powering the Unit These meters can be powered either by four 4 AA size batteries or by the included power supply These units CANNOT be powered from the included USB cable Testing has shown that USB power tends to
5. e time to read through this manual in order to become familiar with the meter Also please pay special attention to the important safeguards shown on the next page Rev 1 3 Aug 2014 Pg 4 of 23 Sample Draw Data Logger Manual CO2Meter com Important Safeguards To reduce the risk of fire electrical shock and or injury to persons basic safety precautions should always be followed when using electrical appliances including the following ad SS READ ALL INSTRUCTIONS BEFORE USING THIS METER INSTALL GasLab SOFTWARE BEFORE CONNECTING METER TO A COMPUTER Do not use rechargeable AA batteries For models using AA batteries do not store the meter with the AA Alkaline batteries installed to prevent the potential for battery leakage Use only the supplied 6VDC international wall power supply adapter Precisely 6V must be applied to the meter Other voltages can cause permanent damage The meter is not designed for outdoor use Do not allow the meter to be exposed to water Do not operate the meter with the enclosure opened Do not operate the meter if it is malfunctioning SAVE THESE INSTRUCTIONS Rev 1 3 Aug 2014 Pg 5 of 23 Sample Draw Data Logger Manual CO2Meter com Package Contents Please verify that your package contains the following items before using the meter All units e 1 Meter e 1 Rubber Boot e 1 6 foot USB Cable e 1 Power supply e 1 User manual Sampling units only
6. gen for ZERO or CO2 close to the concentration being measured Alternatively a 0 or ambient calibration can be performed To perform a calibration attach the unit to your computer power it with the wall adapter and either expose it to atmosphere or supply it with your calibration gas fed with a demand based regulator Open the GasLab software on your personal computer and click the Configure Sensor button For data logging units click the Turn Pump on Continuously button to ensure continuous flow To apply any change has to power cycle the unit Zero or Fresh Air Calibration Apply gas and select the appropriate concentration in the screen shown in Figure 10 Click the Calibrate button The sensor reading should instantly reflect the calibration High Concentration Calibration Write down the original Zero Value before adjustment for future reference Apply the desired concentration calibration gas adjust the Zero Value in increments of 10 pressing the large Save button on the right until the unit displays the correct concentration Rev 1 3 Aug 2014 Pg 17 of 23 Sample Draw Data Logger Manual Device Specifications Measuring Range 1 CO2 5 30 65 100 CO2 Repeatability 0 1 CO2 0 5 0 30 0 65 0 100 CO2 Accuracy Air Quality Level Power Supply Maximum Voltage Minimum Voltage Power Consumption Sensor Ratings Life Expectancy Maintenance Interval Warm up Time Pump Cha
7. ies it disables enables data logging Otherwise it turns the unit on off Barb Fittings Connect to sampling system for closed loop sampling Figure 2 Components Power Source All units can be powered by four 4 AA size batteries not included but sampling units can also be powered by the included 6VDC International wall power supply Setup Our sampling device will require minimal setup since it is designed to be portable The most important aspect of the setup involves connecting the sampling hoses and ensuring proper setup Figure 2 above shows the labeled components of the unit as referenced throughout the rest of this manual Rev 1 3 Aug 2014 Pg 9 of 23 Sample Draw Data Logger Manual CO2Meter com Sampling Only Models These models are used for sampling of closed loop CO2 systems and collection of real time data There is no initialization required for these models Units may be powered by the AC Adapter or batteries While sampling these units may be connected to a personal computer and used with our GasLab software to record samples or it can be used as a stand alone sampling device Data Logger Models These models feature an internal memory capable of storing data when not attached to a personal computer These units will allow you to simultaneously read and store CO2 concentration level data Due to the nature of their design these units should be connected to your personal computer first before oper
8. librated to operate within the specified range and precision Calibration The calibration process varies depending on the type of unit and whether it has optional data logging functionality or not All units are factory calibrated with multiple reference points of gas and have been verified to be accurate within their specific functionality before shipment However if the unit is severely jolted or otherwise mechanically disturbed the sensor can drift requiring recalibration All calibration procedures follow a single point calibration routine that effectively shifts the zero point of the CO2 sensor 0 1 or 0 30 Sample Draw Unit Calibration can be performed using either 0 CO2 calibration gas typically nitrogen Argon etc or using a fresh source of air assumed to be approximately 400ppm Attach calibration gas to the unit and connect the unit to a personal computer Open the calibration screen in the GasLab software Click the Calibrate button in the calibration tab for the desired gas located in the Configure Sensor screen As long as the gas concentration is Stable the unit should instantly reflect the calibrated value This can be confirmed by watching the display To see the calibration value in real time click in the Collect Real time button to capture these values before opening the configuration screen Rev 1 3 Aug 2014 Pg 15 of 23 Sample Draw Data Logger Manual CO2Meter com 0 1 or 0 30 Sa
9. ls under normal use during the warranty period an RMA Return Material Authorization number must be obtained from CO2Meter com After the item is received CO2Meter com will repair or replace the item at our discretion To obtain an RMA number please call CO2Meter com at 386 256 4910 When requesting an RMA number please provide the reason for return and original order number If we determine that the product failed due to improper use water damage dropping tampering electrical damage etc or abuse or if it is Rev 1 3 Aug 2014 Pg 20 of 23 sample Draw Data Logger Manual CO2Meter com beyond the warranty period we will inform you of the cost to fix or replace your device If you are returning your device due to a warranty claim with an RMA number and you still have the unit original package please use it to ship your unit to us Please make sure to include the provided RMA number on the outside of the box preferably on the shipping label Make sure you secure the unit inside the package properly to prevent any damage during transit that could void your device s warranty Finally please ship your device to the address shown under the Contact Us section below CO2Meter com will not under any circumstances be responsible for your shipment expenses and no refund will be issued for shipping charges necessary for you to ship the unit to us Liability All liabilities under this agreement shall be limited to the act
10. mpling Unit with Data Logging Calibration can be performed using either 0 CO2 calibration gas typically nitrogen Argon etc or using a fresh source of air assumed to be approximately 400ppm Calibration Procedure To calibrate your unit follow these steps 1 Expose the unit to ambient air assumed to be at 400ppm or connect it to a calibration gas bottle cylinder 100 nitrogen or argon with the appropriate demand regulator Wait 25 seconds to collect a sample Write down this value as the before value Click the Calibrate button after selecting your calibration gas Wait 25 seconds again This time the unit will take a sample and use this data to adjust zero values The displayed measurements will reflect the new calibration value 0 or 400ppm Disconnect the Calibration gas and wait 25 seconds The newly displayed data will now reflect the new sensor calibration If the sensor is still operating outside of its specified range repeat this procedure When the readings vary too greatly the calibration will silently fail and may need to be performed again Rev 1 3 Aug 2014 Pg 16 of 23 Sample Draw Data Logger Manual CO2Meter com 0 5 65 100 Sampling Unit with or without Data Logging The 0 100 units do not feature Automatic Background Calibration ABC algorithm due to the CO2 scale they measure To ensure the highest accuracy we recommend calibrating these units with calibration gas Nitro
11. ncluded GasLab manual Usage Pump only In order to use the unit hoses tubing must be attached to the inlet and outlet fittings on the front of the unit The pump will draw air from the inlet in a vacuum configuration push it through the sensing chamber and exhaust the air out through the outlet Rev 1 3 Aug 2014 Pg 12 of 23 Sample Draw Data Logger Manual CO2Meter com Particulate Hydrophobic Water Trap Figure 3 Filters setup We recommend installing the included humidity particulate filter to ensure the sensing chamber and pump baffle stays clear and corrosion free Replacements filters are available on CO2meter com http www co2meter com collections co2 sensors products sensor pump kit filters traps Rev 1 3 Aug 2014 Pg 13 of 23 Sample Draw Data Logger Manual CO2Meter com Closed Loop Operation SAMPLING DEVICE Vacuum Pump Humidity Filter EXPERIMENTAL CHAMBER Sensing Chamber Figure 4 Closed loop sampling setup Open Loop with Environmental Exhaust SAMPLING DEVICE Recommended Vacuum Pump Humidity Filter EXPERIMENTAL CHAMBER Sensing Chamber Environment Figure 5 Opened loop sampling setup Rev 1 3 Aug 2014 Pg 14 of 23 Sample Draw Data Logger Manual CO2Meter com Theory of Operation The CO2 sensor inside this device uses non dispersive infrared technology to sense as a function of transmitted light the concentration of CO2 in the air It has been factory ca
12. produce inconsistent supply voltage and degrades sensor accuracy In the units without data logging the switch on the front will turn the power ON or OFF allowing for storage with the batteries installed for long periods of time In units with data logging the switch on the front has been dedicated to enabling disabling data logging As long as the unit has good batteries or the power adapter is connected the unit will be operating If the unit is not going to be used for an extended period of time batteries should be removed from the unit LCD Display if applicable The Liquid Crystal Display LCD screen shows the following features e CO2 in parts per million ppm for 1 and 5 models e CO2 in percentage format 4 for 30 65 100 e Logging On Off e Percentage of memory free Rev 1 3 Aug 2014 Pg 11 of 23 Sample Draw Data Logger Manual CO2Meter com Quick Start Guide IMPORTANT MAKE SURE TO INSTALL SOFTWARE BEFORE CONNECTING YOUR DEVICE TO YOUR COMPUTER 1 Install new batteries Duracell recommended or connect the included power supply 2 Install filters and tubing included as shown on Figure 3 open loop or close loop 3 Forsample draw meters turn the switch ON to begin sampling For sampling data logging turn on the switch to begin collecting data 5 Ones sampling is complete data can be downloaded to your computer through GasLab 6 For more details on how to download the data refer to the i
13. racteristics Maximum Flow STP Maximum Vacuum Maximum Pressure Maximum System Pressure Rev 1 3 Aug 2014 CO2Meter com 0 10 000 ppm 0 5 0 30 0 65 or 100 vol 20 ppm 1 measured value 0 1 2 of measured value 30ppm 5 measured value CO2 concentration 9VDC 6VDC 0 5W avg pump running gt 15 years No maintenance required lt 1 min instant measurements 0 40 LPM 150 mbar 500 mbar 1 atm Pg 18 of 23 Sample Draw Data Logger Manual CO2Meter com Troubleshooting guide Symptom Possible Cause Resolution Issue Device Sensor Your device s batteries might be depleted Replace is not the batteries with fresh ones or if applicable recognized by connect the device to the included power supply PC Device doesn t Make sure the power adapter is plugged properly power ON and that there is power in the outlet the adapter is connected has the appropriate voltage If using batteries make sure they are not depleted The GasLab Your software might be out of date Update your software software by either visiting our download webpage doesnt start at http www co2meter com pages downloads or by selecting the Check for Updates under the Help menu Make sure your PC meets the minimum requirements not obstructed doesnt change mode Bat and The power adapter output voltage is green LED inappropriate Please use the power adapter with keep flashing correct 5
14. recsananeasas WARRANTY ssiscesscssstenuasspasiseaeaceassnensahsevessnenesdenandeeas RETURN S sracnak n S LIABILITY sissusecatessvsscaasenessaessnessossaneansessaansansesecsiansss Rev 1 3 Aug 2014 CO2Meter com Pg 3 of 23 sample Draw Data Logger Manual CO2Meter com Welcome Thank you for purchasing our meter CO2Meter Inc is a Florida based business specializing in the design and manufacturing of gas detection and monitoring devices mainly CO2 Our approach is one based in the science of gas and how best to accurately and repeatedly measure that gas for the end users purposes Our business partners in Agriculture Medical Pharmaceuticals Science Beverage and other fields find our devices to be highly accurate and cost effective We approach each customer s application as a unique opportunity to understand educate and provide product solutions that meet the customers needs while exceeding their expectations for reliability and service Our continued product innovation in combination with our customer first focus allows CO2Meter Inc to continue to provide solutions for the future Based in Ormond Beach FL CO2Meter Inc is committed to the success of our customers the health welfare and prosperity of our talented employees and the continued development of our local community CO2Meter Inc appreciates your business and looks forward to working with you and your team in the future Please take som
15. st meet the following requirements e Windows XP SP3 or higher e Microsoft Net Framework 3 5 SP1 e Pentium 4 or newer operating at 2 4Ghz or faster e 1GB of Random Access Memory RAM e Hard disk space with at least 20 Megabytes MB free 200 MB recommended for logs and application files Software is compatible with 64 bit operating systems and is fully tested with Windows 7 Rev 1 3 Aug 2014 Pg 7 of 23 Sample Draw Data Logger Manual CO2Meter com FAQ Privacy Policy AboutUs Testimonials Search Contact Your shopping cart is empty amp CO2Meter com S c 386 872 7665 Sales 386 256 4910 Support Sales CO2Meter com CO2 Measurement Specialists Home Sensors Portable Fixed Wall Mount Data Loggers Custom Download News App Notes Reviews Software amp Documentation Downloads GasLab Sensor Configuration amp Data Logging Software GasLab is our next generation software specifically designed for all CO2meter supplied sensors development kits and assemblies Real Time Gas Level Figure 1 Install GasLab online Internet Explorer 9 shown Rev 1 3 Aug 2014 Pg 8 of 23 Sample Draw Data Logger Manual CO2Meter com Product Overview Display Shows CO2 concentration level and data logging status optional Removable Protective Boot Gently peel boot from top of unit to access batteries and USB connector for connection to PC Power Switch If the unit has data logging capabilit
16. ual cost of the product paid to CO2Meter com In no event shall CO2Meter com be liable for any incidental or consequential damages lost profits loss of time lost sales or loss or damage to data injury to person or personal property or any other indirect damages as the result of use of our products Rev 1 3 Aug 2014 Pg 21 of 23 Sample Draw Data Logger Manual CO2Meter com Contact Us We are here to help For information or technical support please contact us support co2meter com 386 256 4910 Technical Support 386 310 4933 Sales t www co2meter com Address CO2Meter Inc 131 Business Center A3 Ormond Beach FL 32174 USA Rev 1 3 Aug 2014 Pg 22 of 23 sample Draw Data Logger Manual CO2Meter com NOTES Rev 1 3 Aug 2014 Pg 23 of 23

Download Pdf Manuals

image

Related Search

Related Contents

5-Meg Hard Disk Service Manual (1982)(Tandy)    ATTrBuTE v3 User Guide  System and method for" Plug and Play" ability to broadband network  Desguarnecedora de balastro  Configuration Manual - XT3 11.01  ―取り扱い説明書―  Bosch UPA-1220-50  User`s Manual  DECISIÓN DE LA COMISIÓN de 28 de agosto de 2001 por la que  