Home

UV Transilluminator User Manual

image

Contents

1. screws 8 32 machine screw 3 16 long silver mcmaster carr 91772A189 Rubber O ring Large 9557K459 Assembly Instructions Step 1 Connect power The ballast and power entry with switch in the kit are partially assembled wires have already been soldered to the power connector and the lamp ballast as described in a previous Instructables step In the step you will mount these parts to the enclosure and use twist on wire nut connectors to connect the power entry to the ballast Parts Enclosure base Ballast Hardware Bag A enclosure side with cutout power connector power connector adapter 1 Place the ballast onto the base plate and secure in place with the ballast screws Tighten down with the screwdriver Note the correct orientation of the ballast on the base plate below 1 http www instructables com id UV Transilluminator step3 Connect AC power to ballast 2 Thread the power connector through the power connector adapter and then through the enclosure side with the cutout Secure in place with the power connector screws Tighten down with the screwdriver 3 Place the assembled part from the previous step onto the base plate in the orientation shown in the picture below 4 The twist on wire nut connectors will be used to connect the two neutral white and live black wires a Take the ends of the two black wires and line up the frayed ends Twist the wires together b Insert the wire bundle
2. stained with ethidium bromide As ethidium bromide is a toxic chemical with strict safety protocols it is only recommended that you use this dye in a lab with established handling storage and waste disposal procedures in place Other users are strongly recommended to use the less toxic dyes such as SYBR Safe instead which can be handled and disposed of more safely 2 The transilluminator does come with a safety lid for viewing the gel However when the lid is not in place safety glasses must be worn when operating the UV B bulb
3. UV Transilluminator User Manual Enclosure v 2 0 design files and build instructions Introduction Open source enclosure design files UV Transilluminator kit contents Acrylic enclosure parts Enclosure Hardware Assembly Instructions step 1 Connect power Step 2 Enclosure base assembly Step 3 Enclosure top assembly Step 4 Attach the lid Viewing a gel with the UV Transilluminator Introduction UV transilluminators are used in molecular biology labs to view DNA or RNA that has been separated by electrophoresis through an agarose gel During or immediately after electrophoresis the agarose gel is stained with a fluorescent dye which binds to nucleic acid Exposing the stained gel to a UVB light source causes the DNA dye to fluoresce and become visible This technique is used wherever the researcher needs to be able to view their sample for example sizing a PCR product purifying DNA segment after a restriction enzyme digest quantifying DNA or verifying RNA integrity after extraction This User Manual describes how to make a narrowband UV B transilluminator with a 7 5 x 7 5 cm window suitable for viewing and imaging DNA mini gels The kit contains all of the materials for making the transilluminator Assembly time is approx 30 60 mins No additional tools required Specifications e Enclosure 19 8 cm long x 14 9 cm wide x 6 5 cm tall e Viewing window 7 5 cmx 7 5 cm e Output wavelength 305 315 nm with a peak at 311 nm See at
4. into the connector and twist the connector clockwise until tight It should fit tightly on the wires Test by pulling on the connector to ensure if does not come off the wires c Repeat steps for the two white wires Step 2 Enclosure base assembly Step 2 parts Assembled part from Step 1 3 x enclosure sides 4 x enclosure standoffs 4 x enclosure base screws hardware Bag B UV B bulb 1 Take one of the enclosure base screws and thread it through the corner holes on the enclosure base On the opposite side of the enclosure screw in one of the enclosure standoffs Repeat for all 4 corners of the enclosure base 2 Insert the UV B bulb into the ballast and place the remaining enclosure sides into the slots in the enclosure base Step 3 Enclosure top assembly The top part of the transilluminator has a total of 4 layers of acrylic which are used to mount the diffuser the transilluminator glass and a UV transmissive protective cover These top layers are secured in place with the four enclosure top screws and the standoffs Step 3 parts Assembled part from Step 2 diffuser UV transilluminator glass four remaining acrylic top plates enclosure top filter holders 2 and solacryl cover plate diffuser screws enclosure top screws hardware Bag B 1 Attach the diffuser to the 4 enclosure top using the diffuser screws 2 Place the enclosure top onto the assembled enclosure from the previous step with the diffuse
5. nator glass 8 25 cm square Power connector with on off switch 6 power cord to as Ye Ye Acrylic enclosure parts Each kit contains the following 16 laser cut acrylic parts Five of the acrylic parts have been pre tapped with threads for the appropriate screw size Enclosure base 2 x 8 32 holes for mounting ballast Enclosure top 4 x 4 40 holes for mounting diffuser Enclosure side 2 x 5 40 holes for mounting power connector UV transmissive cover 4 x 8 32 holes for mounting hinges Hinged lid 4 x 8 32 holes for mounting hinges Enclosure Base Enclosure Top Enclosure Sides Power connector adapter Filter Holder 1 1 4 Filter Holder 2 1 16 Hinged lid assembled in kit IO Rodeo UV transilluminator Enclosure Hardware Bag A Hardware for connecting power step 1 C a Power connector screws 5 40 Thread 1 2 long silver mcmaster carr 91249A108 Ballast screws 8 32 Thread 1 8 long silver mcmaster carr 91772A188 Bag B Enclosure hardware steps 2 amp 3 C a Enclosure standoffs 4 40 hex standoffs 2 long mcmaster carr 91780A174 Enclosure top screws 4 40 machine screw 1 long black mcmaster carr 91249A123 Enclosure base screws 4 40 machine screw 3 8 long black mcmaster carr 91249A108 Diffuser screws 4 40 machine screw 3 16 long black mcmaster carr 91249A102 Rubber O ring Smali SG57KA57 Bag C Hinged lid hardware step 4 EC o Hinge
6. r on the inside of the enclosure as shown in the image below 3 Place filter holder 1 onto the enclosure top Next place the transilluminator glass into the filter holder slot 4 Next place filter holder 2 onto the enclosure followed by the UV transmissive cover In each corner place an O ring and one of the enclosure top screws Tighten down with the screwdriver Step 4 Attach the lid The kit comes with a clear acrylic lid for viewing gels This lid does not pass UV light and is designed to completely cover the viewing window area Step 4 parts Assembled part from Step 3 Hardware Bag C Acrylic lid 1 Place the four O rings over the hinge holes Line up the hinges and loosely attach the hinges to the top of the enclosure as shown using four of the hinge screws Next loosely attach the two hinges to the lid using the remaining screws Once the lid is seated on the enclosure tighten all of the screws Note this lid can be swapped with an amber lid When switching between lids simply unscrew the hinges from the lid and replace it with the new lid Viewing a gel with the UV Transilluminator Once you have your mini gel prepared and stained place it onto the transilluminator underneath the hinged lid as shown in the Images below Always operate the UV B bulb with the hinged lid closed Switch on the transilluminator At this point you should see your DNA bands Safety Notes 1 The gel above has been
7. tached spec sheet for more information on the UVB bulb Open source enclosure design files All of the enclosure designs files and BOM for the transilluminator are published by IO Rodeo on our bitbucket site under Open Source licenses The design of this current version 2 0 of the UV Transilluminator is a slight modification of the UV Transilluminator v 1 0 described in a previous Instructable tutorial The design has been modified slightly as described below e Viewing window increased to 7 5 cmx 7 5 cm v 1 0 was 7 cm e Design now includes a 9 cm UV transmissive diffuser which sits above the UV bulb e Power entry switch now sits on the side of the box for easier access within a commercial Imaging Enclosure e Acrylic material used to make the five parts of the enclosure base and sides has been changed to 1 8 black acrylic v1 0 was 1 4 black acrylic e An additional part on the top has been included in this design to prevent any light leakage around the sides of the transilluminator glass e New enclosure dimensions 19 8 cm long x 14 9 cm wide x 6 5 cm tall e Changes to the hardware see the project on_Bitbucket for the new BOM e Safety lid clear or amber has been increased to 10 cm x 10 cm v1 0 was 8 2 cm x 10 cm UV TransilIluminator kit contents Each kit contains the following components Acrylic enclosure parts and assembled lid 3 bags of hardware Mini screwdriver Ballast with lampholder UVB bulb UV Transillumi

Download Pdf Manuals

image

Related Search

Related Contents

GSTY-A0ーBE G-Styーe タールサマーオーニング ページュ  GUI for PMBusTM control User`s manual  Induction Cooker  日本語版取扱説明書[PDF, 約 1MB]  LevControl LCD  Décembre 2012  MarketMaker:Desktop A.1.1 CFD Software User Guide  Vigo VG08006 Installation Guide  Descarga el 1er Número del Volumen 1  Black & Decker JS515 User's Manual  