Diagnoskop
Contents
1. Overvrite with confirmation Auto Rename Imported Configurations C Confirm All Imported Configurations Options for directories with identical names e Auto Combining into One Directory advised The contents of the imported directory are placed inside the existing one in the standard directory No question is asked e Auto Renaming the imported directories The imported directory is copied under a new name with a particular number added to it Thanks to that you can find out what has repeated Here is also no question asked e Combining into One Directory with confirmation For the imported directories with identical names a certain information is shown see below and you have to decide what should be done with them e Confirming all the imported directories For each imported directory you have to confirm first if you want to import it For the directories with the same names the information is also shown see below Options for configurations with identical names e Overwriting with confirmation advised A simple question is asked if you want to overwrite the existing configuration e Auto Renaming the Imported Configurations The imported configuration is copied under a new name without any question e Confirming all the imported configurations For each imported configuration you have to confirm first 1f you want to import it The information below is shown for the directories with identical names Confi
2. Availability of the connector is signalised by turning on the red functional control LED at the front of device Calibration See While measuring with the current clumper probe or with the sensor of concentration of CO in fumes in Channel C the calibration window will be shown just after every acceptance of channel settings This window enables you to establish the zero level so that the 0 measurements are precise The left indicator shows the required level of measurements and the right one the present readings Now you should regulate the device so that the right indicator is Current Probe very close to the required level it is signalised with a change of the button to gt gt OK lt lt 19 69 A 11 Tool buttons Thanks to the tool buttons you can change the parameters of measurements very quickly Oscilloscope work mode e e a E E SYNC INC 40 000 Jale 1 Time base e Left arrow button a higher time base slower measuring Right arrow button a lower time base faster measuring Synchronization settings A button switching the slope increasing decreasing to synchronization from Channel A B button switching the slope increasing decreasing to synchronization from Channel B You may switch the slope by clicking the right indicator of levels of synchronization with the right mouse button eo 8 nN You may also change the time base by pressing Time B
3. the graph occupies one quarter of the height of the window a d the particular quarters e 1 2 a b the graph occupies the upper a or lower b part of the window e 1 1 the graph occupies the whole height of the window Zero level If the measurements of a chosen graph include negative values a small white spot will appear on the position indicator of this graph and it will mark the zero level If there is no white spot it means that the measurement includes only positive values For Channels A and B the indicator of the zero level is in the middle of the graph and for Channel C it is in three quarters of the height of the graph It means that e g for measuring the temperature the range 1s from 0 up to 120 degrees over the spot and from 0 to 40 degrees below the spot Channel D used for measuring the rounds of the engine measures only positive values so it does not have any indicator of the zero level Cursors To help you with analysing the recorded graphs the program gives you the possibility of using the time cursors and the momentary value cursor If you want to choose a type of the shown cursors press Cursors The display shows the cursors as vertical lines running through the whole height of its window The cursors are shown when the measuring is stopped Cursors Values Time Period Help The momentary value cursor lets you see the values of the graphs for one chosen measurement T
4. Firm Into Comment F 605 battery test You can choose the printer and its parameters in the shown window e g coloured or black amp white if your printer has such a possibility in this case you should press Settings 24 If you confirm the printing now the present contents of the display window and of the information windows will be printed This printout is created as coloured so if you choose the black amp white printing you will receive different shades of grey The same contents but without the top and a comment may be placed in the Clipboard if you want to use them in the other programs see Using the Clipboard Before the printing starts you can add the comment that will occur under the display window If it is needed you can also change the information about your firm It will be printed on top of each page Using the Clipboard DIAGNOSKOP program lets you use its data easily in other programs e g Microsoft Word If you want to use this possibility press To Clipboard A MAP SENSOR 40 DI B LAMBDA PROBE 1 6 7 DIW 4 C Injector 8 me DIY D RPM DIS CYL 2 4000 rpm DIY A bitmap with the contents of the display window and the information windows will be placed in the systemic clipboard The same contents are placed on the printout see Printing To use this bitmap in the other program you just have to choose Edit from its menu and the Paste option ADVICE You
5. You can write a few pages of description in the displayed window up to 30000 characters Heasurng Description HALL SENSOR CONHECTOR THREE CABLES 1 GROUND 2 SIGHAL RECTANGULAR WAVE o FEED 50 LOCALIZATION IGHITION S 3TEH TASKS IGNITION MANAGEMENT RPH IHJECTOR STROKE If the configuration containing a description is loaded the window with the description will be displayed If you close it you can make the measurements If you want to read the description of measurements concerning configuration again press Description in the main window When you need to change this description e g because of a mistake load the configuration and save it in the same place under the same name if the new version of the program occurs it may be changed After displaying the saving window remember to press Edit Description so that you can change it and next OK to save the configuration with the new description While saving the configuration you may want to create a new configuration directory In this case press New Directory Creating of such directories is also possible in the configuration manager window see Configuration Manager In the opened window you should write the name of the new directory and optionally the eight character s MS DOS Name You do not need to give the MS DOS Name if the Suggest Name option is marked the program checks which directories already exist and suggests the name that does not clash with
6. measuring of positive and negative values and settings concerning synchronization If you turn on the synchronization there will be a synchronization indicator on the left side of the display that you can move with the mouse To make the measurements using the induction and capacity LEDs in a secondary ignition system you have to turn on L amp C Probes option in the Channels window of the oscilloscope mode After the acceptance with OK the functional control LED at the front of the device will change into green Another two checkboxes Show Peaks in Channel A and Show Peaks in Channel B will be marked in the same window This function enables you to display the maximal momentary values and makes the observation of the separate peaks easier useful in the measuring of the primary and secondary ignition system Channels Oscilloscope Range F6 Ca M Negative Values Peak Sensor F8 TLE Probes Triggering fiINC F Channel A DEC lt F Show Peaks in Channel 4 C Channel B l Show Peaks in Channel B cence E e The Synchronization settings let you choose the channel with which the displaying of the graphs should be synchronized and the level crossing of which should make drawing the graphs start You may also choose if displaying should start from the increasing INC or decreasing DEC slope of the signal You may regulate the voltage of displaying level of synchronization directly in the main window of
7. Maximal absorbing of current 400mA Cooperation with PC computer through the parallel port LPT Width x Height x Depth 120 x 42 x 200 mm The producer gives you 24 months of warranty for the device
8. window configuration import You can use it to extend your configuration base helping you with making different measurements First choose the user directory from which the configurations will be imported see The base configuration directory When you mark the Import Configurations to Standard Directory option two buttons Options and Import will be activated You only have to press Import to start the importing When the import is finished or cancelled because of an error you will see the proper information The importing process is led in such a way that the new configurations are copied to the existing standard configuration directory as it is shown on a diagram below NEW EFFECT ORIGINAL MAKES MAKES MAKES AUDI AUDI AUDI _ probe measuring measuring E miestor SL measuring2 measuring2 TOYOTA a C probe BMW A COROLL _ injector FORD _ ignition BMW OPEL FORD TOYOTA OPEL UNIVMEASUR 5 TOYOTA COROLLA ignition UNIVMEASUR test If you want to choose the specific way of leading the import at first press Options The way in which the program works if it meets the elements with the same names is explained below 21 Import Options Directories with Identical Hames Ok C Auto Rename Imported Directories Cancel C Combine into One Directory with confirmation ddil Help C Confirm All Imported Directories Configurations with Identical Hames
9. Configuration Directory Not Connected In the displayed window you can point the port to which the device is connected If you are not sure which port it is you may press Detection and the program will automatically find the device if it is really connected to the computer and it is powered If you choose the Not Connected option the program will not conduct any graphs so it will not make any measurements Calibration lets you suit the parameters to the device You can also recalibrate the oscilloscope it is needed when you have changed the port of the device different ports transport the data with a different speed or when the measurements made in the oscilloscope mode are inaccurate The firm information window lets you establish the text of the top of every printout of the program see Firm Information It is advised to enter the correct infomation about your firm just after installing the program It is enough to do it once the data are kept and used with every starting the program The information about the work modes is shown on the top bar of the main window of the program in a given work mode It is possible to change the names of those modes as you like The advanced settings contain two commands e Configuration Manager displays the window in which you can manage the already existing directories and files of configuration see Configuration Manager e Configuration Directory lets you look through the co
10. Diagnoskop To do this you should move the indicator on the left side of the display with the mouse up to the demanded level see Tool buttons Measuring pages of the Oscilloscope You may use so called measuring pages You may place a different graph on each of them so that you could compare them all for example In any moment you may switch to the next page by pressing Page Down and to the previous one by pressing Page Up The buttons are active not only when you look through the paused measurements but also during measuring There exists only one measuring page in the measurements given by KME Therefore there is a possibility of saving your own data on next pages and comparing them very easily The number of available pages depends on the chosen time base e g for 100 ms DIV one page for 50 ms DIV two pages etc and for the time base of 2 ms DIV 50 pages This is the result of a constant amount of memory allocated to the loading buffer 9 Measuring channels Recorder Diagnoscope Apart from the channels of the oscilloscope mode see Channels Oscilloscope there exist two additional measuring channels for the recorder and diagnoscope modes multifunctional Channel C and R P M measuring in Channel D Channels Diagnoscope and Recorder Fa Channel 4 Channel E Hame it Mame Range F5 kan Range F6 40 0 idde ss 16 0 Ai 78 0 2 1 6 fe 4 Negative Values Channel D Measuring Type Fr
11. Pulse Width 0 16 ms Positions Hame Injector Mas Value Unit ome tee In Channel C you may change the type of measuring see Universal Channel When you press F7 or Channels you will see the list of types There are available measurements of e g e Duration of pulses negative e Concentration of CO in fumes e Vacuum Pressure e Frequency AEB Feedback e Pressure e Current e Temperature e Voltage Channel D is used to measure rounds of the crank shaft of the engine While measuring with the induction probe there may occur some errors in the measurements jagged line of a graph or no change of the graph when the engine rounds have changed They may be caused by different kinds of the high voltage cables e g monitored or of high resistance They may also occur when you would diagnose the ignition system with an untypical solution e g Twin Spark Then you have to take the signal from the minus pin of the sparking coil from the output of the ignition module from the Hall sensor or induction sensor position of the crank shaft or from the ignition device You may do it after removing the end piece of the induction probe and putting the Chinch plug on the banana shaped connector An example of the testing connector Mercedes 1 signal of rounds R P M 2 earth 3 output of the testing signal 4 signal of the minus pin of the sparking coil 5 plus pin of the storage battery after turni
12. can make the so called screen projection You only have to press Print Screen to place the picture of the whole screen in the clipboard You can also use the AIt Print Screen buttons to place the picture of the whole present screen with its contents in the clipboard 25 Problems and suggestions We want to ask for your opinions about DIAGNOSKOP program its work and documentation Your suggestions may help us with developing and making our product better If you have a diagnostic problem that you cannot solve problems with interpreting the graph or you want to share your opinions with others then gt Ifyou have an access to the Internet send us a file with your data and your opinion and we will place it on our site Thanks to that all the other users can discuss the problem gt Send us a disk with your file and your own comment gt Print the graph that you are interested in and fax it to our number 48 42 719 05 71 You may find us under these phone numbers 48 42 719 05 70 Monday Friday 8 00a m 4 00p m Send the e mail to our address kme kme com pl Visit our Internet site regularly www kme com pl Equipment requirements Equipment requirements computer of the PC class min 486 DX 100 MHz 8MB RAM of memory CD ROM drive 30 MB free on a hard disk 3 5 disk drive a mouse Windows 3 1 or 95 LPT parallel port The standard equipment of DIAGNOSKOP KME Diagnoskop device 1 piece Rem
13. measuring graphs are magnified on the display as many times as you have chosen Scrolling Apart from magnifying the graphs horizontally and vertically there is also the possibility of scrolling the information contained in the display window Scrolling is realized by using the following buttons e PageUp switching to the next page e PageDown switching to the previous page e Ctrl lt Ctr1 moving ten measurements left or right You may scroll the display window with the mouse using the scroll bar You may find this bar under the display and it shows which part of data you can see on the display The exact number of a measuring page is shown in the information window on the right side of the display window 20 29 65 If the parts of two pages are shown on the display both numbers are seen in the information window Ooo o ol Graphs positons on the display The position of graphs in the display window is signalized with displaying a line of a proper colour on the graphs positions indicator This indicator also includes the information about the zero level of every given channel see Zero level If a graph is not shown on a whole height of the window it is easy to check on the graphs positions indicator you may press Channels and change the position of the chosen graph in the Position list Position Available possibilities e hidden the graph is not shown e 1 4 a b c d
14. or CMOS Frequency 200Hz up to 2 4kHz input C measuring in standards TLL or CMOS Measurement of the step motor position for AEB Feedback positive pulse width up to 5ms universal input signalized by the red LED at the front of the device measuring in standards TTL or CMOS Current measurement through the Current Clumper Probes up to 600A input C sensitivity ImV A Current measurement through the Current Clumper Probes up to 60A input C sensitivity 1OmV A CO measurement through the device universal input signalized by the red Led at the front of the device TEMPERATURE measurement from 400C up to 1200C universal input 10 Voltage analogue measurement from 0 2 up to 0 6V universal input 11 Pressure measurement through the device 0 up to 1800kPa 18 Atm different from the atmospheric pressure possibility of declaring different units PSI mmHg bar 12 Vacuum pressure measurement through the device 0 up to 760 mmHg 100 kPa different from the atmospheric pressure possibility of declaring different units PSI Atm bar Channel D Measurement of rounds of the crank shaft R P M for DIS 2 3 4 5 6 or 8 cylinders with the induction probe for the engines with the spark ignition with the piezoelectric probe for Diesel or directly form the induction hallotrone and other sensors signals with amplitude of gt 1 6V Input impedance of 1MOhm for Channels A and B and about 100kOhm for Channels C and D Time base sp
15. 0V a unit of division Measuring ranges only for positive values 0 to 1 6V 0 to 8 V 0 to 16V and 0 to 40V for negative and positive values 1 6V 8V 16V 40V Zooming up to x10 Possibility of establishing the graph position on a display a whole screen 1 2 screen the upper or the lower one Synchronization of the graph from the chosen channel and for the chosen values in the whole measuring range with the 8 bit resolution increasing or decreasing slope A single measurement may be started after fulfiling the synchronization requirements or automatically after 5 seconds it is chosen with the Single Measuring button A function allowing to store the maximal values of the graph Peak Sensor The cooperation with the capacity and induction probes for measuring the secondary ignition systems it is controlled by the program signalized by the green LED at the front of the device TECHNICAL DATA OF THE DIAGNOSCOPE RECORDER MODE The simultaneous measurement of 4 input signals 9 Channels A and B 2 channel digital oscilloscope for low frequency graphs 8 bit resolution for a channel measuring ranges the same as in the oscilloscope Channel C possible measurements Pulse width negative 0 up to 16 ms input C measuring in standards TTL or CMOS Pulse width negative 0 up to 40 ms input C measuring in standards TTL or CMOS Frequency 20Hz up to 240Hz input C measuring in standards TLL
16. CO in fumes fuel injection pressure in ZS engines diesel flash point Diagnoskop KME is a good alternative for other devices of this type considering its price and quality Introduction Diagnoskop connected with the diagnostic device to PC computer enables you to observe analyse and record the electric graphs that occur in cars electric end electronic devices You can observe simultaneously up to four measured graphs and you can use this program as a digital oscilloscope for the faster graphs You may save all the recorded graphs so that you could analyse them later their number is limited by the capacity of the computer disk In order to make the choice of settings easier the program enables you not only to create the sets of the most used measuring channels configurtions in all the work modes but also their quick choice according to the suggestive name You can also create the exemplary diagrams and keep them with their configurations settings as e g models You can find the tens of standard settings added to the package that may be modified by you You can find other examples and configurations on our Internet site www kme com pl Diagnoskop KME enables you to make the measurements of e converters MAP MAF TPS piezoceramic e g stroke bore ratio combustion sensor e sensors oxygen probe 1 Hall magnetoelectric optical e g ABS ETS DSC ignition systems e injector opening time or step motor position in LPG dev
17. KME Diagnoskon version 1 69 USER S MANUAL pphu KME Marek Kuklis ul Osiedlowa 4a 95 100 ZGIERZ tel 48 42 7190570 fax 48 42 7190571 e mail kne kme com pl http Awww kme com pl June 2001 INDEX Diagnoskop KME Why aioe rerio oo omni eiseols oa mets 3 OO a bereeerenre eee eee ore ter entrtonyie fervOlr ie ata ne arene te eee tape rr Seren Pe aren Fo ge rat eee Ne TENT ee ree 4 The main window of IDLAG NOS 5 sice6 eth cseiesdsalaleastalctesw tic shelter ciate dase tieawta deus tid aleedy hic A haveGa 5 Sfarin CHS prog raone na eat Sasa betas ea od Se atadre ala a EG hc a tad ls oad heey ta 5 NY OLS MOUE Sarna E T E E E E 6 Meast oa e men ae a ee ee 6 SWS AG AS UPN ee onesie A T tonsa cnet a naatinet gas 7 Measuring channels Oscilloscope a5ecie oo sohd cacecveccetee et sev ee cctatcoded coxaceaeratee bet iareeecetatecbelcovesteeraiveiedeea te 8 Measuring channels R cordet Dia gnoscope seoce ier ie EEE A E a 9 Umversal channel E sses anna a E a austria ineteseeetien 10 Calibra nrm a E 10 TOOLDU O e A a a nr rien OSE nny ee are 11 ZOOP N a E E N EE tie te A E EAG ade tad ado E a att 12 SCHON eeann a a eee 12 Graphs postons on Medis pli y onersn eea A AAN 12 A E a ET OEE ET A E AE EE T AE E A E AEI T AAE AEE T A 13 USOT a a a a eden uaa pate tessenaadanst 13 Savr and oade dilaanan ee ee no el en oe no T 14 Program setin Sige 1 7s00 say casesanesalariu a ai ae Heat ee alee aE 15 Work WAU COMIMOUTATI
18. ONS 2x i os s0iis jst cess E E mae neon aes 16 COMI IOUPA IONIAN AG C0 srera acta enact TAN E leone aa ee eee 18 The basic Conti ouration directory ssssc s arsseesazestacsnapsade sadaptacteigaaessagestacinapoale A Er aa ANRA EE REDT 19 COMMOUPATION IMPON eire e T EE E EE 20 COn S AOE POT e a A ey eRey aoe HtosnnneT peer a 22 Pr Ona OU s ee Ea a E a E EER E doped EA ES 23 Graphs PENON oea E N EE O EE O 23 Usine theC Hpboi dear a O eee 24 Problems and SUS CCST ONS neasi aee E N E E T E 25 EaupmMen reduire Ie IS raaa eT A ET EE A EEO E 25 Toche tek ee e E e T a Som aa ne om eae Nee ae emer een eee ee 26 Diagnoskop KME Why A device changing the PC into a tool for diagnosing electric systems in Cars Diagnoskops are devices enabling you to observe the electric graphs in any place where the current is the information carrier Modern cars are filled with the sophisticated electronics and it becomes more and more difficult for the mechanics to get rid of all the faults That is why Diagnoskop is a necessary and useful device in reparing injection systems ignition systems and other cars circuit Diagnoskop in the workshop is a simplification not only for a mechanic it is also a benefit for a customer Competition laws more often occur in motor industry Service owners have to take into consideration a fact that a loyal customer may suddenly turn to the neighbouring better equiped workshop The image of the firm is very important for its pro
19. ark the chosen configuration in the Configuration Files list and press Show Selected Configuration Description Configuration manager If you want to see the window of the manager press Settings in the main window and then Configuration Manager see Program Settings Configuration Manager Fa Configuration Into Close Help Fath c diagnosk contigs pomiauntukfadvtryke jetra M5 D05 Name l TF l l Hew Directory Configuration Files Directories _New Directory EJ chdiagnosk contig E UNIVERSAL MEASUREMENTS fq INJECTION SYSTEMS Ey KEJETRONIC LAMBDA PROBE 19 Configuration files and directories are created in the files system so they may be organized just like any other files by using standard tools as e g Files Manager in Windows 3 1 or Explorator Windows in Windows 95 DIAGNOSKOP saves the long name inside every configuration file and it creates the additional file DIRINFO INI containing the long name inside each configuration directory Configuration manager just allows you to modify the information easily Creating configuration directories To do this you should use the New Directory button You can create the new directory either in the manager window or during saving the configuration to the file see Work with configurations Changing the configuration and directory names You just have to press one of the Change Name buttons The window of changing the names will be display
20. ase see Measuring time Notice that there is the indicator of levels of synchronization near the left side of the display window You may change the level of synchronization by moving the indicator fy with the mouse To change the settings of synchronization or Channels A and B just press Channels see Measuring channels Recorder and Diagnoscope work modes LAMBDA PROBE oe DIY fale DIS yL 2 4000 rom DIV DELAY 100 187 Dy Le 3 Settings of Channel A also B e Up arrow button higher measuring range e Down arrow button lower measuring range e Minus sign including negative values e These buttons are available in all the work modes 4 Delay settings e Left arrow button longer delay lower measuring e Right arrow button shorter delay faster measuring e w sign displaying of the currently measured values You may change the settings of the channels by pressing Channels see Measuring channels You may also change the delay by pressing Delay for the diagnoscope mode or New Measuring for the recorder mode see Measuring time Zooming If you cannot see the graph clearly you can magnify it horizontally see Graphs positions magnifying vertically the possible magnifications x2 x4 x5 x8 and x10 The chosen value is shown on the right side of the display window If you want to come back to the first settings choose the magnification of x1 The
21. cording up to 31 200 measurements 65 pages of display from four measuring channels You have a choice of the measuring speed and you may observe the measured values at real time It enables you to spot all the irregularities that occur during measuring The diagnoscope mode resembles the recorder mode but it uses only one cyclically looped window of the display It lets you examine the measurements constantly when you do not need to record such a great number of data You may also switch quickly from the diagnoscope mode to the recording of measurements see Measuring In every work mode you may save the measurements on a disk and later load and analyse them Measuring If you want to begin measuring in the oscilloscope mode just press the Start button It will change then into the Stop button which you can use to stop measuring You may also do it by pressing Esc If you want to start measuring in the recorder mode press New Measuring you may choose then how many measurements the program should make When the measuring begins you may use the Stop Continue buttons until the program completes the measurements In the diagnoscope mode the measurements are made in the same way as in the oscilloscope mode There is also an additional possibility of quick switching from the diagnoscope mode to the recording of measurements just press Record Now The program will change the work mode into the recorder a
22. ctory the one that is inside the directory in which the program has been installed that is why it is called standard 20 If you want to you may use a different Mmaa directory You only have to choose the User Defined option and enter the path to the BMectow Ok required directory or search the directory using ee the window of choosing the directory which r you can see after pressing Browse B import Cancel lI Help After accepting the user directory with the Use button you can load the configurations save them change their names and delete them in a normal way The chosen directory is shown as the first position in the Directories Drives list in the windows which you can use to point the configurations i e Save Load c system and Manager ADVICE It is quite important to look through the directory from which you would like to import the configuration before you will do that You may check then the configurations that are contained in the directory e g the taken from the Internet ones and decide if you need them all You can delete the unnecessary ones and just then import the configurations see Configurations import If you did not do that it would be difficult to find and check all the new configurations because they would be connected and mixed with the already existing ones Configuration import There is another one option in the Configuration Directory
23. ed and you can enter a new name of the directory or configuration in the lower editing window Rename configuration Path o c diagnosk contig makes audie09041 8 Sruma From jLAMEBDA PROBE To LAMEDA PROBE two cables cored e Deleting the configurations and whole directories In this situation you should point the configuration or directory that you want to delete and press one of the Delete buttons IMPORTANT BE CAREFUL If you choose deleting of the directory everything that it contains will be deleted You may delete very useful configuration and it may occur that you will have to reinstall the program The basic configuration directory The window of choosing the basic configuration directory will be shown when you press Settings in the main window and then Configuration Directory see Program settings Configuration Directory Use Configuration Director Use c diagnosk contig User Defined Cancel Help Browse Options Import Configurations to Standard Directory Import e O ih rae O mot In this window you can change the standard configuration directory into another one so that you can e g look through the configurations given to you by the other user or taken from the Internet Thanks to this option you can establish where the source of configurations that you use while working with DIAGNOSKOP begins When you start the program it uses the standard CONFIG dire
24. eed of measuring 100ms 10s a unit of division the range of the time base depends on the computer configuration Sensitivity of Channels A and B from 200mV up to 10V a unit of division Drawing the graphs on the display with the simultaneous reading of the momentary values for four channels The possibility of recording up to 65 pages of the graphs display windows in the recorder mode The possibility of establishing the proper position of the graphs on the display the whole screen 1 or 1 of the screen whichever half or a quarter of the screen COMMON TECHNICAL DATA FOR THE OSCILLOSCOPE 21 AND DIAGNOSCOPE RECORDER MODES Maximal input voltage up to 400V Momentary value cursors simultaneous reading for all the displayed channels Time periods and frequency cursors DT and 1 DT Zooming up to x10 Edition of the measuring channels names up to 20 characters and of the used units up to 7 characters Unlimited number of measuring configurations with the model graphs and configuration groups possibility of creating and modifying them Saving the diagrams on a disk with your own comment The possibility of printing the screen with the comment data time and your firm address Stopping and continuing the measurements in any moment Sending the diagrams display window to the clipboard the possibility of pasting them in a new Windows aplication e g Microsoft Word Corel PaintBrush PhotoShop Voltage of feeding DC from 10V up to 28V
25. figuration directories to another computer on a floppy disk or send it through the Internet we would like to encourage you warmly to send the configurations to our e mail kme kme com pl In this situation you have to lead the export of configuration see Configuration export To save the present configuration of the program you have to press the Save button in the Configuration window or press F2 You will find then a window in which you can choose the directory and name of the configuration that you want to save Save Configuration Configuration Info Name L4MBO4 PROBE Path cdiagnosk contig pomiaunhukfadwtrle jetro Save Cancel Help M5 D05 Mame LAMBORPAO DSC M Suggest Name Configuration Files Directories E cdiagnosk contig E3 UNIVERSAL MEASUREMENTS INJECTION SYSTEMS New Directory ike Additional Elements i Measuring Description Edit Description M Add Graph as Data Model The currently displayed diagram may be also added to the configuration You just have to mark the Add Graph as Data Model option The configuration that is saved in this way contains just beside the settings the measurements that were made and which will be loaded and displayed after loading such a configuration I7 It is needed to add the description to the configuration It will be displayed with every loading You just have to mark the Measuring Description option and press Edit Description
26. fits If the employees occur to be real specialists work competently and use modern diagnostic devices the customers trust increases as well as the firm incomes KME is a producer of Diagnoskop in a form of a device added to the PC Why did we choose such a solution Here are the reasons e We use PC which can be found in most of the workshops to work with Diagnoscope you may use a computer with not very high paremeters that has been used until now only to make out bills and to manage the shop e A low price of Diagnoskop as a device the integrated diagnoskops are of much higher prices e Great measuring possibilities resulting from the resourses of PC the program enables you to record an unlimited number of data containing the current graphs and measuring configurations e Operating the program is pleasant resulting from using Windows 3 xx 95 98 e You can easily suit the configuration base of the program which analyses the data sent by the device to the computer to your own needs using the program or you can ask the producer to change the base e g for the needs of the service net There are standard settings in the program for checking the elements of injection and ignition systems characteristic for a particular car makes as well as of the standard measurements e A possibility of measuring while driving the car so called road test using a notebook e Because most of the educational institutions have computer
27. hanks to that you may find e g the highest and the lowest value of the graph in a chosen moment Time cursors let you measure a time period between two measurements as well as the frequency of the graph You will find such information on the right side of the display window You can move cursors using the mouse or the following buttons e Value cursor Alt Left and Alt Right e Left time cursor Alt Up and Alt Down e Right time cursor Alt Left and Alt Right 14 Saving and loading data In every work mode you may save data that are made by you The part refering to the present work mode is saved together with the measurements Thus when you load your data you will have the same state of the program as it was in the moment of saving Save Data File Hame Directores Ok c diagnosk dane Enter the file EJ cA Cancel name here WA Te i impO 40 rec a agnos ke jet rec dane ke jetr rec cim pozr jet_pr rec holand Peugeot rec List Files of Type Drives Recorder rec E c system Enter a Comment description to the graph here You can add a comment to the file that you want to save Next you should enter the name of the file in which the data will be saved Data files undergo the same limitation as all the files of other programs 1 e the file name cannot have more than 8 characters and it cannot include characters as lt gt and spaces Load Data Choo
28. he graphs in real time in the display window you cannot predict how fast the measuring will be finished Instead of that the information about how much time the process takes is shown in the top information window after the whole unit of division has passed M Show Values a Moreover every measurement that is made has its own information about the time moment in which it was finished so you can measure the time periods very carefully e g by using cursors In these modes you can also display the values of measurements You only should mark Show Values and then apart from graphs you may observe the recorded results in the momentary value window REMEMBER Displaying of the momentary values while measuring Show Values is marked will delay the measuring time If you turn off the displaying of values you will achieve an interesting effect the time spent on one unit of division with the minimal delay will be shortened about 100 ms DIV depending on the speed of a computer Thanks to that you will be able e g to record quite fast graphs without switching to the oscilloscope mode Measuring channels Oscilloscope The program enables you to suit the measuring channels to the work mode If you want the channel configuration window to appear just press Channels or click the right mouse button in any place of the display window There are two measuring channels for the oscilloscope mode 4 ranges of the measured values
29. ices linear diagrams e engine crank shaft rounds taking into consideration the number of cylinders e electromagnetic valves of e g engine de aeration EGR free rounds controlling fumes recirculation injector e data transmission CAN Bus e storage battery starter alternator tests e ignition systems secondary and primary e current and relative compression of cylinders using Current Clumper Probes e and many others The device is connected to the IBM PC through the printer port LPT The program communicates with the device makes measurements and presents them on the monitor screen You can print them or send to the clipboard and use them in the other program The main window of DIAGNOSKOP The following picture shows the main elements of the program that you will work with Diagnoskop 1 68 recorder ME ES MAP SENSOR 40 DIY LAMBDA PROBE Ov DIY a ms A DIM DIS CYL 2 4000 rpm DIV PAGES Bo measurements 31200 100 1s DW ggn hd DISGNOSEOP E 20 29 65 Description MAF SENSOR 4 33 LAMEDA PROBE 0 75 Injector 12 30 RPM 1400 E i Contiguration a 7 Work Mode Continue OOM Load Data Print Load F New Measuring Channels Settings Cursors Save Data To Clipboard Save F2 e Display shows the measurements that are made by you e Graphs positions indicator shows you which part of the display is used by the particular graph e Function choosi
30. n port will let you program the device e g choose the voltage dividers On the other side through the port the program reads the measuring data from the device After installing the program you should enter the present information about your firm which will be found on the top of every printout of the program You may also enter this information later The front of the device Functional control LED Diagnoskop KME Gniazdo uniwersalne Sondy pojemn induk Universal connector Sonda poj IMPORTANT Description of the functional control LED Red colour means that the universal connector is active in the recorder diagnoscope modes Signals to Channels A and C are received only through this connector Green colour means that the connectors of L amp C probes are active in the oscilloscope mode LED does not produce light active connectors A B C D induction LED for the recorder diagnoscope modes or A and B for the oscilloscope mode Work modes TREE The Diagnoskop program has three work modes e oscilloscope Oscilloscope e recorder e diagnoscope __ Recorder To choose one of the work modes just press the Work Mode T button and select a demanded mode in the shown window Each 7 mode has its own specific way of measuring Using the oscilloscope mode you may examine the high frequency signals from two measuring channels Using the recorder mode you may conduct the re
31. nd show a window of new measurements you only have to accept their realization The program will automatically suggest recording of 5 pages of measuring but you can change the number just before the acceptance While the measurements are being made in the oscilloscope mode using the mouse may be difficult If you want to change the settings it would be easier to stop measuring by pressing S or Esc at first Time in measuring Time Base In the oscilloscope mode you can choose a time base that is the Lime DIM most suitable for your measurements You just have to press Time Base The minimal time base depends on the speed of the computer that you are working on You may also make the measurements with the highest available speed the number before which lt sign stands You can change the time base in the main window by using buttons that you may find near the top information window For the recorder mode you choose a delay by pressing New Measuring and for the diagnoscope mode by pressing Delay Delay Delay Rate Hew Measuring Delay Fate Pages 1 65 measurements 2400 M Show Values coed O te The program counts the delay for recorder and diagnoskop modes in a form of measurements that are skipped You can change the delay and displaying of momentary values in the main window by using buttons that you may find near the top information window Notice that because of drawing t
32. nfigurations contained in the other directory that are given by another user or taken from the Internet see The basic configuration directory 16 Work with configurations You can find the buttons of saving and loading the configurations in the main window After choosing your own settings of the measuring channels in all the work modes they let you save those settings as a configuration under a certain name Thus if you want to make similar measurements in the future you will only have to load the configuration and the program will return to the required state The program itself also keeps the last configuration the one that you use when you close the program When you start the program again you will find it in the same state as it was in the moment of closing Configurations are files that are kept in a subdirectory CONFIG inside the directory in which the program was installed Configurations are selected thematically by placing them in the proper subdirectories You can create as many different configurations as you want to You can also delete the useless ones and their directories You can name the files and directories by giving them suggestive names not longer than 100 characters You can take the additional configuration directories from the Internet site www kme com pl or from the other user If you want to use them you have to lead the so called import of configuration see Configuration import You can also export the con
33. ng buttons let you choose a work mode begin and end the measuring configure the measuring channels save and load data choose the zoom and show the cursors e Information windows show the set up that is chosen by you in a certain moment e Value cursor and time cursors help you analyse the measurements e Momentary value windows show the values of the measurements in a certain moment that is chosen by you they also show you the values of the present measurements e Scroll bar shows you which part of data is seen on the display Starting the program If you want to begin making measurements you just have to connect the device with the print port and start the program It checks to which port the equipment is connected If the device is correctly connected and powered there will be the main window of DIAGNOSKOP program shown on the computer monitor In the other case you will see the window with an information about the lack of connection to the device or about the lack of power After closing it with OK the main window of the program will be shown Then you have to check precisely the connections with your computer and the source of power turned on a red function LED at the front of the device choose the settings window with the Settings button and conduct the detection of the port see Program Settings Choosing the port is a base for a proper cooperation between the program and the device Communication through the chose
34. ng on the ignition 6 plus pin of the storage battery Universal channel C Channel C available in the diagnoscope and recorder modes is adapted to make different types of measurements The following list shows the measurements that are available in this channel Channel C Measuring Type Fr Pulse Width 0 16 ms Universal analog Pulse Width 0 16 me Pulse Width 0 40 ms Frequency 20 Hz up to 240 Hz Frequency 20 Hz up to 2 4 kHz Current Clumper Probe up to 600 A Current Clumper Probe up to 60 4 Temperature Pressure Vacuum Pressure Carbon Monoside C0 max 6 Feedback AEB step motor In Channel C you can make the measurements of e Duration of pulses negative e g the opening of injector two ranges 0 40 ms and 0 16 ms e Frequency two ranges from 20 up to240 Hz and from 0 2 up to 2 4 kHz e Current current clumper probe two ranges 60A and 600A e Concentration of CO in fumes through the device range 0 6 e AEB Feedback opening position of a step motor of actuator or pulse width 0 5 ms e Temperature through the device in the range of 40 C deg up to 120 C deg e Vacuum Pressure through the device up to 760 mmHg 100 kPa e Pressure trough the device up to 1800 kPa 18 Atm e Voltage from 0 2 V up to 0 6 V IMPORTANT The measuring is made through the universal connector for AEB feedback CO concentration measurement pressure vacuum pressure and temperature marked with
35. ory with Use e Enter the configuration manager now see Configuration Manager and delete those configurations that you do not want to export FINISHED The last thing that you can do is to compress C EXPORT directory with the archiving program as e g WinZip You may export the completed file to the next user We would like to encourage you to send a copy of the exported configurations to kme kme com pl We will place these configurations on our Internet site www kme com pl so that all the other users may use them Firm Information The Firm Info window lets you choose the top of every printout of the program Firm Info Fim wis Address ul Osiedlowa 4a Phone Other If you want this window to be displayed press Settings and in the Firm Info window press Edit Each element can have the maximal number of 60 characters There is also a button displaying the Firm Info window inside the Print window see Printing IMPORTANT It is advised to enter the correct infomation about your firm just after installing the program It is enough to do it once the data are kept and used with every starting the program Graphs printing If you want to get the printout from the program press Print Print Printer Default printer HP Latenlet Series Il K on LPT 1 Cancel FP Setup Selection Pages Help Fror To canes Print Quality 300 dpi Print to File l Collate Copies
36. ovable Frame for installing the device inside the computer cover 1 piece Connecting cable computer device 1 piece Induction Probe Chinch plug banana shaped connector 1 piece Capacity Probe 1 piece Feeder cable from a car battery 1 piece Measuring cables red green and blue 3 pieces altogether A cable to connect the earth of the engine 1 piece CD ROM with the program 1 piece The user s manual 1 piece Additional equipment option A printer port card LPT for the simultaneous work of Diagnoskop and the printer Feeder cable from a car lighter Current Clumper Probes e g 600A A cable to connect the Current Clumper Probes A device for measuring the Pressure and Vacuum Pressure A device for the observation of the fuel injection in the ZS engines Diesel A probe for measuring the tempereature Connecting cable to the AEB Feedback A device for measuring the concentration of CO in fumes A set of capacity probes for measuring the secondary and distributorless DIS ignition systems Workshop equipment shelves for a computer monitor printer and an arm for the probes 26 Technical data TECHNICAL DATA OF THE OSCILLOSCOPE MODE Digital Oscilloscope 2 channels resolution 8 bits for a channel Input Impedance 1MOhm Time base Ims 100ms a unit of division 6 ranges the minimal time base depends on the computer configuration Sensitivity from 200mV up to 1
37. rm directory import AUDI Directory already exists C Rename imported directory Do not import this directory abot Heb 22 IMPORTANT The default options of importing are Auto Combine into One Directory and Overwrite configurations with confirmation Using these options is advised because they let you avoid a mess in case of e g importing a configuration twice from the same directory Configuration export The way of exporting the configuration explained on this page will be changed in the new versions of DIAGNOSKOP program Using of the tools typical for managing the files as e g Files Manager in Windows 3 1 or Explorator Windows in Windows 95 is needed to export the configurations The exporting process is led as it is shown on the diagram ORIGINAL COPY EFFECT MAKES MAKES MAKES AUDI AUDI AUDI measuring measuring measuring measuring2 measuring2 measuring2 BMW APY G FORD FORD G OPEL TOYOTA UNIVMEASUR test e Using one of the previously named programs find the directory in which DIAGNOSKOP program is installed There is a directory with configurations inside it it is called CONFIG Copy this directory to e g the main directory of disk C and change its name into C EXPORT e Next change the configuration directory see The base configuration directory Point C EXPORT as a user directory Confirm this direct
38. s it is possible to use Diagnoskop in teaching on the base of four simultaneously drown graphs it is easy to comprehend the interdependence between the particular elements e The program enables the users to create their own measuring configurations settings with new names that can be used when they make the same measurements again You can record the measuring data for later analysing them or as characteristic graphs which can be used as measuring models defining correct or incorrect work of the measured elements Diagnoskop KME has a lot of functions that distinguish it from other devices of such type e g e Recording of four low frquency graphs simultaneously up to 30 minutes Such a work mode enables you to find untypical faults occurring rather rarely e Cursors system is necessary for precise analysing the current graphs Momentary value cursor enabling you to read the values of Y axis simultaneously from four channels 1 e voltage current pressure frequency pressure vacuum pressure temperature injector opening time RPM and others Cursors for measuring the time periods At ms and frequency f Hz e The possibility of cooperation with other measuring interfaces produced by KME devices enables you to make the complex measurements of the motor work parameters pressure up to 18 Bar compression in cylinders oil fuel vacuum pressure in lifting commutator temperature current pressure of e g starting loading
39. se a measurement File Hame Directores Ok fle iane c diagnosk dane i Cancel fido rec S ok fido b rec i ImpU 40 rec fy ke jet rec ane ke jetr rec at poar l jet_pr rec holand peygent re Choose a type of YP D Files of Type Drives Recorder rec E c system You can see Data type Version Creation date a description RECORDER 19 09 2000 to the graph Comment here F 605 battery test 15 Notice that there are additional elements in the shown window If you point some file the program will automatically recognize its version and type If you added the comment to the data during the saving process it will be also shown In this way you may easily and quickly find the interesting file Each work mode has its own types of files which it uses during the saving process While loading the work mode is switched if it is necessary and the settings of the measuring channels are updated thanks to that you can find the environment in the same state in which it was while saving Program settings You can change the settings of the program after pressing Settings Settings Device lO Port Detect Calibration Work Modes Information Oscilloscope 1 Osciloscoape oscilloscope Recorder recorder i 0278h CU f 3 Diagnoscope diagnoscope i O378h Curent Probe Advanced Settings C 02BCh Configuration Manager D3BCh
40. them Create New Directory New Directory Info Hame ELECTROTECHNICAL MEASUREMENTS Path c diagnosk config M5 D05 Name ELECTMESA M Suggest Name coed ob If you want to load the configuration press Load in the Configuration window or press F3 Then point the directory and the configuration that you are interested in and press OK 18 Load Configuration Configuration Info Name HALL SENSOR Cancel Path cAdiagnosk contig makes audi e09041 8 Sruna ddi MS DOS Name HALLSENS DSC Help Configuration Files AIF TEMPER SENSOR Directories E3 c diagnosk conhig ENGINE TEMPER SENSOR E MAKES HALL SENSOR iy AUDI INJECTOR HALL E 80 90 E LSL 55k AU MONO MOTRONIC L4MBD4 PROBE MANAGING SIG OF IGNITION MODULE MINUS OF SPARRING COIL SECONDARY IGN SYSTEM TEST TPS SETTINGS Options I Only Configurations with Data Models Show Selected Configuration Description The configuration will be loaded If the configuration contains its model it will be also loaded and shown on the display If you want to see only those configurations containing models choose the Only Configurations with Data Models option If the measuring description was added to the configuration the window with such a description will be displayed If you want to start measuring this window should be closed However if you want to see the description of the configuration without loading it m