Home

Start Up Manual

image

Contents

1. SUPPLY VOLTAGE 230 V 125 previous order power supply frequency 50 60 Hz MAXIMUM OUTPUT 300 420 900 W depending on the model MAXIMUM OUTPUT POTENCY 360 W P E P 3 x 120 PROTECTOR FUSE 7A This device uses radiofrequency currents to perform the treatment Possible radio interference has been reduced to the minimum Nevertheless certain characteristics of the building where the device is being installed can further reduce the possible radio interferences for instance un earthing with a resistance that s too high lt may therefore be convenient to take some additional measures Whenever possible we suggest taking the following measures a Availability of an independent earthing used for the CEYA device exclusively Install the devices in a room that acts as a Faraday protection The non ionizing radiation in the levels and potencies produced by the device are absolutely harmless for your health The only necessary precaution is to make sure the device is being operated by a person qualified to give the client an appropriate treatment This device has a special level of protection against electrical discharges especially in relation to the allowed leakage current and the re liability of the ground faulte protection 3 2 Label Model CEYA 3000 N S S00000CH BLONSIDE S L U Sant Marti de l Erm 22 08970 Sant Joan Desp Barcelona EA CE 220 110V 50 60Hz 600VA Made in Spain Fuse 3A 6A 5x20mm Ea d ta amp
2. damage the electricity cables and the electronic components Metal dust is destructive for electrical devices Temperature In order to assure the best working conditions for CEYA we recommend a room temperature of 20 C to 25 C and a relative humidity below 80 Safety warnings Dangerous tensions exist inside the device The devices pannels cannot be removed under any circunstances CEYA generates high tension radiofrequency energy For a safe application the active and passive plates must be applied correctly to the skin of the treatment area An inappropriate positioning of the plates may cause skin burns Never use accessories that present any kind of damage for instance damage in the cable s isolation the electrode s surface the adherence of the materials of the passive and active plates to the silicone substract etc An inappropriate use of the device with an excessively long treatment and or excessively high potency levels can cause skin burns which may generate hypertrophia atrophia or anormal pigmentation or a combination of these three effects Esos ua 8 Mub lirio Chapter 7 Maintenance 7 1 General ideas CEYA requires the following periodical maintenance Before starting a treatment the insulating material of the active plate must be checked carefully for imperfections damages to the surface scars in the insulation or any other type of imperfection Do not use the active plate if you find any kind of da
3. Las reparaciones derivadas de un choque mec nico cat strofes naturales defectos de la instalaci n el ctrica o uso impropio no quedar n cubiertas por la garant a De igual forma cualquier tipo de manipulaci n mantenimiento y o reparaci n por parte de personal no autorizado comportar la perdida autom tica de la garant a 7 7 Asistencia t cnica Para cualquier informaci n adicional sobre el uso y o solicitud de asistencia t cnica contactar directamente con BLONSIDE S L C Sant Mart de l Erm 22 Pol gono Industrial Font Santa 08970 Sant Joan Desp Barcelona Espa a Tel fono 34 93 477 42 63 Fax 34 93 477 42 90 Chapter 8 La JAR OF GEL ELECTRICAL NETWORK CABLE ELASTIC STRAPS Za Q CORPORAL COAXIAL COUPLER FACIAL COAXIAL COUPLER PASSIVE PLATE ACTIVE PLATE SAFETY CONTROL BUTTON X ed 5100060 5111013 5100010 5112016 210054 5111028 5111029 5111030 5111091 5111092 5100087 5100086 5112019 5111037 D YN 0 des Je o Q E 0 a lt o o 2 o o o ai 9 o E o D dE Je ls gt D vn des Je y o 2 Q E 4 o o o o 2 o o o ai ke o E DECLARACI N DE CONFORMIDAD DECLARATION OF CONFORMITY 89 336 CEE 73 23 CEE ENERO 08 JANUARY 07 Nombre del Fabricante BIOINSIDE INVESTIGACI N Y TECNOLOG A SLU Manufacturer nam
4. not selected the appropriate potency Increase the potency until the temperature of your choice Active plate has been cut or crossed Replace with a new plate Passive plate has been cut or crossed Replace with a new plate Failure in the plate s output Contact Technical Service The active plate warms up but the device does not indicate the doses Passive plate has been cut Or crossed Replace with a new plate Failure in the dose counter does not affect the device s functioning Contact Technical Service The coaxial coupler does not warm up It is normal when no thermical sensation is perceived during the coaxial coupler treatment It will possibly take an entire treatment to obtain a slight thermical effect The thermical sensation is almost imperceptible at the beginning and can become more intense throughout the treatment The efficiency is not conditioned by the thermical effect the efficiency remains even when there is no warmth Continue the treatment We have not programmed the timer and we have not activated the timer s ON OFF button Program the timer with the time of your choice and press the timer s ON OFF button until the green led lightens up Coaxial coupler has been cut or crossed Replace with a new coupler Faulure in the coaxial coupler s output Contact with the technical service The coaxial coupler does not seem to be functioning Make sure the green led at the base of the coup
5. notice a lot of heat while working with the plates During the body treatments one notices an excessive warmth that cannot be regulated by selecting lower potencies Verify which part of the plastic cover that protects the plate you are using the side with the gel or the smooth side If you are working with the gel side turn the plastic cover around The treatment has to been done in such a way the smooth side without gel remains in contact with the skin The gel side of the cover is only used when adapting the plates to irregular body parts and at moderate potencies The potency displays indicate 0 EE or do not go to 99 Deconfiguration of the numbers because of the temperature or the nature of the components does not affect the device s functioning Contact the Technical Service You notice a decrease in the device s output Possible drop of tension plates and gel bags wom down We recommend using a tension stabilizer its characteristics are explained in the instructions manual Replace by new ones Chapter 5 DESCRIPTION OF THE CONTROLS 1 Model of the device CEYA 1000 2000 3000 2 General network switch 3 Connection of the network cable 230 V 110V to an earthing 4 Fuse 5 Timer Counts down time 6 Button to start the timer This control button activates and pauses the functioning of the device thusly detaining the beauty treatment 7 Control button to increase the time by ten for instance 10 o
6. ARTING UP THE DEVICE general procedure 1 Before connecting the device to the 230V 110V network make sure the plug has an earthing lead 2 While the device remains disconnected connect the cable of the coaxial coupler to the corresponding active outlet connector 12 1 or connect the active plate to the connector of the corresponding outlet 12 1 While the active plate can be connected to the active plate connectors of the other wndows 12 2 or 12 3 we recommend connecting the facial and corporal coaxial coupler to the connector of the second window 12 1 When working with the two coaxial couplers at the same time the third or fourth window can be used indistinctively 12 2 o 12 3 3 Connect the cable of the passive plate to the connector of the passive outlet 13 When working with the coaxial coupler no passive plate is being used 4 Make sure the power control has been turned to zero 11 5 Put the passive plate in contact with the client s skin 6 Turn on the main switch 2 7 Apply a layer of product to the coaxial coupler or the fixed active plate The plate however can also be used directly without the need of any type of product a When using the coaxial coupler Put the coaxial coupler on the skin surface and move it around in small circles applying an even pressure b Using the fixed active plate b 1 Put the active plate on the treatment area and fix it with elastic straps There most be total con
7. Miblaris Chapter 4 SAFETY NORMS This device accomplishes the safety norms valid at the moment of its production Nevertheless the following safety advice should be taken into account 1 Before operating the device read this manual carefully 2 The device has to be connected to a plug with earthing Never connect to an installation that does not have a circuit breaker 3 The device should not be used on clients with pacemakers or any other active implant 4 This device produces currents fluctuating always between an active plate and its passive partner The heart should never be in between both plates 5 On the way between the active and the passive plate there should not be any metal elements bony prostheses for instance nor should there by any infectuous processes 10 case of doubt consult a specialized doctor 6 The potency control should always be turned to zero when putting the plates on the body 7 Always apply the passive metal plate first followed by the active insulated plate Once the treatment has come to an end first remove the active plate followed by the passive plate 8 Failure to observe the previously mentioned advice may cause burning when applying the passive Metal plate with the device tumed on If this should occur for whatever what reason contact the manufacturer ema ema es or your nearestby distributor 9 This device should be used according to the indications of a qualified profe
8. Start Up Manual Models 1000 2000 3000 JOJEALOY UINOA 39 VAID December 2007 Introduction Chapter 1 Description of the device Chapter 2 Starting up the device Chapter 3 Technical characteristics Chapter 4 Safety Chapter 5 Description of the controls Chapter 6 Installation Chapter 7 Maintenance Chapter 8 Accessories Chapter 9 Assembly of the stand Introduction CEYA is an innovative diathermia device for beauty and physiotherapy related treatments This manual provides the CEYA user with all the necessary information on how to use the device the control pannels safety measures installation and maintenance of the device and it helps to use and to take care of the device but it cannot replace an appropriate training in the appliance of diathermia through radiofrequency devices for beauty and physiotherapy related treatments The manufacturer of the device offers training courses on how to use CEYA This user s manual includes the following information Chapter 1 Description of the device Includes a general description of CEYA Chapter 2 User s instructions Explains how to use CEYA Chapter 3 Technical characteristics of the device Chapter 4 Safety Contains explanations and indications regarding the necessary safety measures when using CEYA Chapter 5 Describes the different controls and their function in starting up the treatments Chapter 6 Installation Explains the electrical
9. ctor for the passive plate metal corresponding to OUTLET 12 3 14 Indicator of the potency applied between the active plates and its corresponding metal passive plates 15 Energy doses obtained throughout the treatment between the active plates and its corresponding metal passive plates 16 Control button to reset the energy dose indicator to zero 15 I ET TT 07 E FTE CE SR a c 3 E Chapter 6 Installation CEYA hos been designed in such a way its installation requires little preparation 6 1 Material you receive CEYA 1000 2000 3000 1 2 3 active plates 1 2 3 passive plates 1 2 3 protective hygienic covers made of polyurethane 1 2 3 protective hygienic cobres of polyurethane with a gel filling 1 network cable for connection to the electricity network Safety control button 1 User s manual 2 4 6 elastic straps 80 cm 2 4 6 elastic straps 60 cm 2 4 6 elastic straps 40 cm Cooxial coupler 41 mm Coaxial coupler 58 mm 6 2 Positioning of the device The device must be placed on a table which is sufficiently stable and solid to carry the device s weight It is important to make sure the table has the appropriate height in order to assure an ergonomic use of the device and its accessories The front feet of the device incorporate a mechanism that allows them to be elevated thusly facilitating the access to the front screen buttons and connectors Keep th
10. e Direcci n del Fabricante SANT MART DE L ERM 22 Manufacturer address 08970 SANT JOAN DESPI Barcelona SPAIN Declara que el producto Electrocosm tico Declares that the product Electrocosmetic Nombre del producto SERIE CEYA Name of the product Marca Brand Cumple con la normativa CE Accomplishes normative Seguridad El ctrica CLASE I TIPO BF Electrical Security UNE EN 60601 Compatibilidad Electromagn tica Electromagnetic Compatibility EN 61000 3 2 EN 61000 3 3 EN 50081 1 EN 55011 EN 5002 1 EN 61000 4 2 EN 61000 4 2 EN 61000 4 3 ENV 50204 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Fdo Eulalia Jaime Ure a Fst tica amp Moailiar a EMA P I Fontsanta C Sant Mart de l Erm 22 08970 Sant Joan Desp Barcelona telf 93 477 42 62 fax 93 477 42 90
11. e device far away from heat sources There must be enough space around the device in order to assure its correct ventilation Make sure to never obstruct the grids of the back and side pannels 6 3 Electrical requirements CEYA is delivered with the voltage corresponding to that of the local electricity network according to the client s order The device can be configurated in order to function with the following input voltage Single phased 230V 10 3A 50 60Hz Single phased 110V 10 6A 50 60Hz It is possible to change the voltage of the device through a Mechanis included in the back pannel of the device The device is earthed through the earth conductor of the network cable which is connected to the electrical installation An appropriate earthing is essential in order to assure a safe use of the device The input lines must be free of temporarily tension or current peaks tension drops or overloads The protector fuses in the devices are 6 A for a 10V tension or 3 A for a 220V tension The devices comes with one fuse In case this one melts down it must be replaced by one with the same characteristics in order to assure safety and avoid the risk of a fire outbreak Warning Make sure the CEYA has been configurated correctly according to your local electricity network tension 6 4 Environmental requirements Quality of the air CEYA must be operated in a non corrosive athmosphere Corrosive materials such as acids can
12. e el fabricante designa como reparables 7 4 Responsabilidad del fabricante BLONSIDE S L es responsable de la seguridad fiabilidad y funcionalidad del equipo nicamente si Las operaciones de montaje ampliaciones ajustes modificaciones o reparaciones son levadas a cabo por personas autorizadas por Blonside S L La instalaci n el ctrica de las salas pertinentes donde se conecte el equipo cumplen con los requisitos adecuados El equipo se utiliza de acuerdo con las instrucciones de utilizaci n recogidas en este manual Se declina toda responsabilidad por da os provocados a personas o cosas que deriven de la manipulaci n incorrecta del equipo falta de mantenimiento o mantenimiento inadecuado o la no observaci n de las directrices contenidas en este manual 7 6 Garant a El equipo CEYA est garantizado por un periodo de 24 meses a partir de su venta siempre y cuando no se produzcan manipulaciones intervenciones y actuaciones en el mismo por parte de personal no autorizado ni cualquier tipo de negligencia en el uso del equipo La garant a se limita a la reparaci n gratuita con la sustituci n de las piezas en las que el personal t cnico cualificado de Blonside S L haya encontrado eventuales defectos de fabricaci n No quedan cubiertas en esta garant a las piezas sometidas al uso y o desgaste por causa de la normal utilizaci n y las que resulten da adas por causa del uso incorrecto o por un mantenimiento inadecuado
13. environmental and space related requirements necessary to instal CEYA Chapter 7 Maintenance Offers a detailed explanation on the maintenance of the device and its accessories Chapter 8 Accessories Describes the accessories used with CEYA Chapter 9 Assembly of the stand Chapter 1 Description of the device We would like to thank you for your confidence in us and the devices you ve just purchased With this device you incorporate the most advanced technology in your center and you introduce a tool which Will rapidly become indispensable in order for you to obtain the best results in your beauty treatments 1 1 Introduction to CEYA This device offers you an advanced electro aesthetic treatment option based on a specific technology called TECHNOLOGY THROUGH ACTIVE MULTIPLATES With this technique you will be able to perform a large variety of applications and you will see how the sessions efficiently turn into great results You will furthermore learn to perform high quality beauty treatments WARNING This device is not a medical health product and it is not aimed at the diagnosis control treatment or soothing of any kind of illness injury or deficiency whatsoever Before starting up the device please READ THIS MANUAL CAREFULLY Failure to do so may be dangerous and may harm thirds We also invite you to contact us or our distributor in case of doubt It will be our pleasure to answer your questions Chapter 2 ST
14. ler is lit The intensity of this pilot varies in function of the potency selected on the device The coaxial coupler does not indicate doses The dose indicador of the outlet to which the coupler is connected does not register the current passing through It is normal no doses are registered when working with the coaxial coupler Continue working The doses increase very fast or very slowly The doses increase very fast when working with the plates or very slowly when working with smaller surfaces This is normal The absorption of doses also depends on the size of the accessories Continue working One plate warms up more than the other During the treatment one pair of plates warms up more than the other This is normal The perception of temperature varies according to the treatment area In Multi plate devices one outlet may warm up more than the others This is a normal effect and has technical causes Continue working The device warms up when the potency button is turned to zero The device continues functioning even when the potency button is turned to zero and the ON OFF button has been activated Contact Technical Service The device is connect but no current passes through The safety control button is connected the time has been programmed the ON OFF button has been activated and no current passes through Disconnect the safety control button and or press the button during the treatment During the treatment you
15. mage to its surface Before starting the treatment the cables and connectors of the active and passive plates should be checked Do not use them if you find any kind of damage and replace them with impeccable accessories After each treatment the active and passive plates should be cleaned carefully This way you will enlarge their life expectation Do not use agressive products such as acids ammonia etc to clean the outside of the device We recommend you regularly inspect the device and its components Contact you distributor whenever you detect any kind of anomaly Warning The CEYA system cannot be repaired by the user Any repair has to be done by the manufacturer or authorized personnel 7 2 Time schedule for maintenance and calibration In the following schedule you can find the regular maintenance operations required by CEYA Checking the isolation of the active and passive plates before each treatment User Checking the cables and connectors of the accessories before each treatment User Visual check up of the central unit Monthly Checking the configuration and the i i GE calibration of the device In case of irregular behaviour Bioinside S L 7 3 Suministro de informaci n t cnica Se proporcionar a petici n esquemas de circuitos listados de componentes descripciones instrucciones de calibraci n y otras informaciones que ayudar n al personal t cnico adecuadamente cualificado a reparar las partes del equipo qu
16. r 20 minutes 8 Control button to increase the units of the programmed time for instance 7 or 17 minutes 9 Jack connector for the client s safety control button 1 The device functions normally without connecting this safety accessory We nevertheless recommend you connect it especially when you re using plates 2 When this accessory is connected the device will only function while the client keeps the button pressed and he can disactivate the device by letting the button go at the first inconvenience 10 Pilot light indicating the device is functioning Submitted to the safety button 9 11 Potency control applied between OUTLET 1 11 1 The coaxial coupler 12 1 or the fixed active plate 12 1 and the metal passive plate 13 1 OUTLET 2 11 2 The fixed active plate 12 2 and the metal passive plate 13 2 OUTLET 3 11 3 The fixed active plate 12 3 and the metal passive plate 133 12 Connector of the big fixed active plate OUTLET 1 121 This fixed active plate only works with the metal passive plate 131 OUTLET 2 12 2 This fixed active plate only works with the metal passive plate 132 OUTLET 3 12 3 This fixed active plate only works with the metal passive plate 133 13 Connector passive plate OUTLET 1 13 1 Connector for the passive plate metal corresponding to OUTLET 12 1 OUTLET 2 13 2 Connector for the passive plate metal corresponding to OUTLET 12 2 OUTLET 3 13 3 Conne
17. ssional beautician CONTRA INDICATIONS Pregnancy Metal prostheses incluided in the electrical field Y Decompensated arterioathy Malignant neoplasias Active infectuous processes Pace Maker Heat insensible persons Technical Service 0034 93 477 42 61 Time 8 a m until 3 p m GMT At other times 0034 93 477 42 63 Make sure to have at hand your warranty date of purchase model of the device serial number your invoice and the distributor s data barera Meblads SOLVING TECHNICAL PROBLEMS We will now solve some of the most common problems that can occur with a CEYA device If you have any further doubt or you believe your device might have a technical problem read carefully the section SOLVING PROBLEMS before contacting our technical service PROBLEM CAUSE SOLUTION The device does not work The device is not plugged in Plug in the device The plug does not receive any electrical current because the fuse has melt down or because the automatic potency limitator went down Change the fuse or reconnect the automatic potency limitator The switch has not been turned to ON Tum the switch to ON The active plate does not warm up and the device does not indicate doses We have not programmed the timer or we have not pressed the ON OFF button of the timer Program the timer with the time of your choice and press the ON OFF button of the timer until the green led lightens up You have
18. tact between the plastic cover of the plate and the skin 16 When using the fixed active plate you might want to offer the client the safety control button which has to be inserted in its corresponding connection 9 This way the client himself can disconnect the device whenever he wants to even when the professional beautician is not around 8 Program the treatment time with the help of the timer 5 Once you have selected the Minutes through the corresponding buttons 7 and 8 press the start button 6 The treatment time will start running as from that moment on 9 Activate the potency control 11 Adapt the potency of the device to the client s heat perception until you obtain a pleasant level 10 Once the treatment time has come to an end a sound signal will warn you that the treatment has finished Press one of the time control buttons to stop the sound signal This action will put the time to 0 and will stop the sound signal It is important remembering that the timer controls the functioning of the device so once the programmed treatment time has come to an end the beauty treatment will automatically detain 11 Consider the dose indicator 15 as a way to measure the energy applied to the person and as an indicador of the evolution in the treatment effect 12 Turn off the device 13 The active and passive plates are to be removed once the device has been disconnected Chapter 3 3 1 TECHNICAL CHARACTERISTICS

Download Pdf Manuals

image

Related Search

Related Contents

Sony CPD-G520P Operating Instructions  Dolog AKF125 → A120/A250 Type: AKF125EN  SOLOGIC A831  GCSBCM2003-033  User manual as  Cables Direct B6-503K networking cable  Pyle PPDM5 sport watch  EVBUM2179 - 10 W Passive PFC Flyback and BuckBoost  RS8CH422 AK2 IO [w-AKC 55] User Manual  Manuale d`Installazione POWERMAX M DC  

Copyright © All rights reserved.
Failed to retrieve file