Home

Manual Changes No. 05-008-1E

image

Contents

1. CE 0038 KEMA No KEMA 98ATEX 3230 EEx dmfia II C T6 T3 ELECTRODE CIRCUIT Um 250Vac dc TEMP CLASS T6 15 T4 T3 MAX PROCESS TEMP 70 85 120 130 C ENCLOSURE IP67 N200 2 2G METER FACTOR VDC 10Wmax VAC 47Hz to 63Hz 10Wmax A WARNING AFTER DE ENERGIZING DELAY 10 MINUTES BEFORE OPENING ELECTRODE FLUID TEMP FLUID PRESS Tamb ENCLOSURE IM User s Manual pte I a O O S MODEL Specified model code SUFFIX Suffix codes of the model code STYLE Specified style code SIZE Nominal size of apparatus METER FACTOR Sensor constant number of apparatus SUPPLY Power supply voltage of apparatus FULL SCALE Meter range CURRENT OUTPUT Output signal of apparatus PULSE OUTPUT Output signal of apparatus LINING MATERIAL Material of liner ELECTRODE Material of Electrode FLUIDTEMP Fluid temperature of apparatus FLUIDPRESS Fluid pressure of apparatus Tamb Ambient temperature ENCLOSURE Enclosure protection number TAG NO Tag number NO Manufacturing serial number CE CE marking Exll 2G Group II Catergory 2 Gas atmosphere KEMA No KEMA 98ATEX3230 Certificate number EExdenia lICT6 T3 Protection type and temp class ELECTRODE CIRCUIT Um Voltage of electrode circuit WARNING Warning to apparatus IM User s Manual YOKOGAWA Name and address of manufacturer 1 The third figure from the l
2. User s Maniial anmac SE Models SE100MJ NJ and SE200MJ NJ Integral Type Magnetic Flowmeter Manual Changes No 05 008 1E Please use attached sheets for the pages listed below in IM 1E10B0 01E 10th Page 12 1 to 12 4 12 EXPLOSION PROTECTED TYPE INSTRUMENT Applicable Standard and Certificate No are added in each Ex proof Technical Data description YOKOGAWA ans Yokogawa Electric Corporation 12 EXPLOSION PROTECTED TYPE INSTRUMENT 12 EXPLOSION PROTECTED TYPE INSTRUMENT In this section further requirements and differences for explosion proof type instrument are described For explosion proof type instrument the description in this chapter is prior to other description in this User s Manual A NOTE The terminal box cover and display cover is locked by special screw In case of opening the cover please use the Hexagonal Wrench attached A CAUTION Be sure to lock the cover with the special screw using the Hexagonal Wrench attached after tightening the cover 12 1 CENELEC ATEX KEMA A WARNING Only trained persons use this instrument in industrial locations 1 Technical Data Applicable Standard EN50014 EN50018 EN50020 EN50028 EN60529 EN61010 1 Certificate KEMA 98ATEX3230 Group II Category 2G Type of Protection EEx dm ia II C T6 T3 Electrode Circuit Um 250V ac dc Excitation Circuit 41V max 6 6 25Hz Temp Class T6 T5 T4 Process Temp 70 85 120 Enclosure I
3. Electrical Code Part and Local Electrical Codes Note a warning label worded as follows Warning WITHIN 50cm OF THE ENCLOSURE UN SCELLEMENT DOIT TRE INSTALL MOINS DE 50cm DU BO TIER A SEAL SHALL BE INSTALLED When installed in Class Division 2 SEALS NO REQUITED 12 3 12 EXPLOSION PROTECTED TYPE INSTRUMENT 3 Operation A WARNING Note a warning label worded as follows Warning OPEN CIRCUIT BEFORE REMOV ING COVER OUVRIR LE CIRCUIT AVANT D EN LEVER LE COUVERCLE Take care not to generate mechanical spark when access to the instrument and peripheral devices in hazardous locations 4 Maintenance and Repair A WARNING The instrument modification or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void CSA Explosionproof Certification 12 4 SAA 1 Technical Data Applicable Standard AS 2380 1 AS2380 2 AS2380 7 AS 2431 AS1939 Certificate AUS Ex 3764X Type of Protection Ex d m ia II C T6 T3 Enclosure Type IP67 Excitation Circuit 41V max 6 6 25Hz Electrode Circuit Um 250V ac dc Temperature Maximum Ambient Maximum Process Minimum Process Code Temperature Temperature Temperature T6 60 C 70 C 40 C T5 60 C 85 C 40 C T4 60 C 120 C 40 C T3 60 C 130 C 40 C Ambient Temperature 20 to 60 C Maximum power supply voltage 250 Vac 110 Vd
4. ING COVER INSTALL IN ACCORDANCE WITH THE INSTRUCTION MANNUAL IM1E10B0 01E e Take care not to generate mechanical spark when access to the instrument and peripheral devices in hazardous locations 4 Maintenance and Repair A WARNING The instrument modification or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void the approval of Factory Mutual Research Corporation IM 1E10B0 01E 12 3 CSA 1 Technical Data Applicable Standard C22 2 No 0 C22 2 No 0 4 C22 2 No 0 5 C22 2 No 25 C22 2 No 30 C22 2 No 94 C22 2 No 157 C22 2 No 1010 1 Certificate 1221381 Class I Groups B C and D Class II Groups E F and G Class III Encl Type 4X Electrodes Intrinsically Safe Ex ia Class I Groups A B C and D When installed in Class I Division 2 locations Seals No Required Electrode Circuit Vmax 250V ac dc Excitation Circuit 41V max 6 6 25Hz Temperature Maximum Ambient Maximum Process Minimum Process Code Temperature Temperature Temperature T6 60 C 70 C 40 C T5 60 C 85 C 40 C T4 60 C 120 C 40 C T3 60 C 130 C 40 C Ambient Temperature 20 to 60 C Maximum power supply voltage 250 Vac 110 Vdc Maximum Working Pressure 4MPa SE115N to SE205N 2MPa SE208N to SE220N Flange rating should be also considered 2 Wiring A WARNING All wiring shall comply with Canadian
5. P67 Ambient Temp 20 to 60 C refer to note below Maximum power supply voltage 250 Vac 110 Vdc Note The minimum temperature is 10 C in case of T3 130 C the 40mm or larger sizes with the carbon steel flange connection or wafer connection 12 1 2 Electrical Connection The type of electrical connection is stamped near the electrical connection port according to the following codes Screw Size Marking N ISO M20x1 5 female AM F ANSI 1 2NPT female A A DIN Pg13 5 female A D D 3 Installation A WARNING e All wiring shall comply with local installation requirements and local electrical code e In hazadous locations the cable entry devices shall be of a certified flameproof type suitable for the conditions of use and correctly installed e Unused apertures shall be closed with suitable flameproof certified blanking elements The plug attached is flameproof certified 4 Operation AN WARNING e Wait 10 min after power is turned off before opening the covers e Take care not to generate mechanical spark when access to the instrument and peripheral devices in hazardous locations 5 Maintenance and Repair A WARNING The instrument modification or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void the certification IM 1E10B0 01E 6 Data Plate a O ADMAG SE MAGNETIC FLOWMETER
6. ast shows the last one figure of the year of production For example the year of production of the product engraved as follows is year 1998 No F261GA091 i Produced in 1998 2 The identification number of the notified body 0344 3 The product producing country 12 2 12 EXPLOSION PROTECTED TYPE INSTRUMENT 12 2 FM 1 Technical Data Applicable Standard FM 3600 FM 3610 FM 3615 FM 3810 NEMA 250 Explosionproof for Class I Division 1 Groups A B C and D Dust ignitionproof for Class II II Division 1 Groups E F and G Leads factory sealed Intrinsically safe electrodes for Class I Division 1 Groups A B C amp D Electrode Circuit Vmax 250V ac dc Temperature Maximum Ambient Maximum Process Minimum Process Code Temperature Temperature Temperature T6 60 C 70 C 40 C T5 60 C 85 C 40 C T4 60 C 120 C 40 C T3 60 C 130 C 40 C Enclosure NEMA 4X Ambient Temperature 20 to 60 C Maximum power supply voltage 250 Vac 110 Vdc Maximum Working Pressure 4MPa SE115N to SE205N 2MPa SE208N to SE220N Flange rating should be also considered 2 Wiring A WARNING e All wiring shall comply with National Electrical Code ANSI NFPA 70 and local electrical code e There is no need of conduit seal for both of Division 1 and Division 2 hazardous locations because this product is sealed at factory 3 Operation A WARNING e OPEN CIRCUIT BEFORE REMOV
7. c 2 Installation AN WARNING e All wiring shall comply with local installation requirements and local electrical code e In hazardous locations the cable entry devices shall be of a certified flameproof type suitable for the contidions of use and correctrly installed IM 1E10B0 01E 3 Operation A WARNING e Open circuit before opening the covers e Take care not to generate mechanical spark when access to the instrument and peripheral devices in hazardous locations 4 Maintenance and Repair AN WARNING The instrument modification or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void the certification 12 4 12 EXPLOSION PROTECTED TYPE INSTRUMENT IM 1E10B0 01E

Download Pdf Manuals

image

Related Search

Related Contents

Operating Instructions Mode d`emploi Manual de instrucciones  Manuale d`uso  Cisco 20-m Single-Ended Cable for HDE1 FMEC  White Rodgers 1F89EZ-0251 Installation and Operation Instructions (Spanish)  Document  FMI GFI55 User's Manual  SCXI-1125 User Manual - National Instruments  Serviceanleitung TNC 150  Hannspree LT13-23A1 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file