Home
HEATED HAND WARMER USER`S MANUAL Three
Contents
1. touch a leaking battery In case of eye contact immediately flush eyes with water and seek medical attention DISPOSAL amp RECYCLING Lithium lon batteries are subject to disposal and recycling regulations that vary by country and region To help promote responsible environmental practices please check and follow the regulations in your area before disposing of these batteries HAND WARMER SPECIFICATIONS Operational Use Temperature 20 C to 60 C 4 F to 140 F Storage Temperature O C to 60 C 32 F to 140 F Relative Humidity 30 to 90 non condensing WARNINGS Electrically heated devices are generally regarded as safe common household products however they can cause harm if not used properly Heat can be dangerous for users with decreased temperature sensation diabetes spinal cord injuries users who have suffered a stroke users taking medication for pain or sleeplessness or those who have been drinking alcohol e Heated hand warmer should not be worn by a person unable to feel pain because of advanced age diabetes spinal cord injuries medication or who has skin that is not sensitive to heat or temperature changes e Heated hand warmer should not be worn stored or recharged in an oxygen enriched environment or near equipment that stores or emits oxygen e Batteries should always be kept away from children Do not submerge hand warmer in water or place in a microwave washing machine or dryer Do no
2. HEATED HAND WARMER USER S MANUAL The Warm amp Safe Heated Hand Warmer was Created to provide maximum comfort in the cold Designed with an innovative and rechargeable three temperature heating system this hand warmer has the ability to keep your hands warm up to 7 hours EASY TO WEAR EASY TO USE This lightweight insulated hand warmer is comfortable to wear and easy to operate and care for In most cases just by keeping your hand warmer clean and dry when not in use and properly charging your batteries it will stay in top condition CHARGING YOUR BATTERY Before using your new heated hand warmer simply plug the AC Charger included with your hand warmer into a standard electrical outlet and connect the cord to the DC input port located on the side of the battery Input ports must be completely dry It takes approximately 4 hours to achieve a full charge The power indicator light will be RED during charging and will change to Green when fully charged Only use the charger supplied with the hand warmer Improper charging could risk fire or explosion CONTROLLING THE HAND WARMER To activate the heat simply press the LED button for 3 seconds The RED LED indicator light will flash for the first 5 minutes during the pre heat warm up period After 5 minutes the LED will change to WHITE for the medium heat level At this time you can press the button to the temperature setting of your choice To turn off the heat si
3. about 50 of capacity before putting it in storage during the off season months e The batteries should be charged for half the required time approximately 2 hours every three months Failing to follow these instructions may damage your battery Here are some of the signs to look for e The battery time drops below 80 percent of the original time expected e The battery charge time dramatically increases PROPER CARE AND STORAGE Your Warm amp Safe heated hand warmer is built to last giving you two to three years of winter warmth and comfort To maintain ultimate performance please follow these simple instructions eWipe clean with a soft cloth and remove any excess snow or water eKeep hand warmer in a dry indoor area at a temperature between 5 C and 20 C 41 F to 68 F eDo not expose the hand warmer or battery to temperatures above 60 C 140 F including open fires or direct sunlight for extended periods of time Overheating could cause batteries to crack which could result in a fire or explosion eKeep battery charged at all times Before storing the hand warmer the battery should be charged to approximately 50 of capacity During off season months the battery should be charged for half the required time approximately two hours every three months eHand Wash ONLY AFTER BATTERY REMOVAL the hand warmer must be completely dry before replacing battery Do not use the hand warmer with a damaged battery eDo not
4. mply press and hold the power button for 3 seconds The power indicator light will turn off A Low battery level will also cause the power to switch off Without power the hand warmer will eventually lose heat However because we ve insulated this hand warmer it will retain warmth for a period of time Three Temperature Levels Red LED is High Heat Provides heat for up to 3 hours depending on the outside temperature This level is ideal for warming up the hand warmer in extremely cold conditions Allow 5 10 minutes of uninterrupted power to reach maximum temperature on high White LED is Medium Heat Provides heat for up to 5 hours depending on the outside temperature This level is perfect for moderately cold conditions Blue LED is Low Heat Provides heat for up to 7 hours depending on the outside temperature This level is used in mildly cold conditions BATTERY MAINTENANCE The lithium lon battery included with the hand warmer has a lifespan of two to three years or 400 charge discharge cycles During this time it s normal for the battery to gradually lose its capacity to hold a charge When this happens the length of time it powers and heats the hand warmer will also decrease To ensure your battery retains its optimum charge and last for as long as possible it s important that it maintains some charge during storage or when not being used for extended periods of time e Charge or discharge your battery to
5. t abuse hand warmer beyond normal daily wear that could damage the batteries and electronics This includes dropping kicking or throwing the hand warmer and or battery or puncturing the battery in any way Do not insert foreign objects into the import ports Do not remove heating unit BATTERY SPECIFICATIONS 7 4V DC rechargeable lithium lon battery CHARGER SPECIFICATIONS Charger Operating Temperature O C to 35 C 32 F to 95 F Storage Temperature O C to 60 C 32 F to 140 F The charger operates over the following voltage ranges Rated input voltage 100 240Vac Operating range 90 264Vac Rated input current O 4A max
Download Pdf Manuals
Related Search
Related Contents
56563 AE Egg Boiler IM_D.indd High Density (80sa) Shelf Assembly Installation Manual HP t510 Mi451 ABRE-PUERTAS DE GARAJE MANUAL DEL PROPIETARIO Data Sheet Spanish Master - Wood Greenway Home Products GWD5960W User's Manual Polycom 1500 C IP Phone User Manual Copyright © All rights reserved.
Failed to retrieve file