Home

User Manual Audéo YES

image

Contents

1. and battery status For detailed information on the use of your myPilot please refer to its user guide or ask your hearing care professional myPilot available in two stylish colors high tech gray or white For optimum results position your myPilot as shown in the drawing Operating range max 50 cm 20 N P p lt y Do not use your myPilot in locations where it is forbidden to use electronic devices ZoomControl This special hearing program allows you to choose from four directions in which to focus your hearing system front back left or right ZoomControl can be accessed via the myPilot command center only 23 Fine tuning based on your personal preferences The fitting process has limited capabilities of reproducing the full spectrum of your personal sound environments This limitation is overcome by the ability of the Aud o YES hearing system to learn from your real life volume adjustments When used with a myPilot Aud o YES offers a unique functionality called Self Learning In every environment it logs your personal volume changes within the hearing system This means that every time you change the volume of your Aud o YES hearing system this correction is taken into account to apply your preferred volume automatically when you are in a similar environment next time Self Learning cleverly ensures that your volume corrections in each environment contribute to a fully personal
2. Aud o YES User Guide C PHONAK Welcome 5 Description 6 Preparation 9 Replacing the battery 9 Identifying left and right Aud o YES 12 Inserting Aud o YES with xReceiver and dome into your ear 13 Closed domes 15 Inserting Aud o YES with Shell 17 Operation 20 Switching On Off 20 myPilot optional 22 Fine tuning based on your personal preferences 24 iCom optional 25 EasyAudio and EasyBluetooth 26 Warning Maintenance 27 Microphone Protector 27 Important points 29 32 Service and Warranty 33 Phonak distributors worldwide 34 Velcome Congratulations on choosing Audeo YES the most sophisticated wireless communication device currently available It uses the latest advances in digital sound processing to automatically adjust to your listening needs Aud o YES provides the highest sound quality speech understanding listening comfort and wireless connectivity for all your personal communication situations Its modern design is inconspicuous when worn and ensures optimal placement on the ear for best performance Aud o YES is a quality product developed by the Swiss company Phonak a world leader in communication technology innovation and reliability Please read this manual carefully to benefit from all the features of Aud o YES With proper care Aud o YES will support your hearing and communication needs for many years If you want additional information about Aud o YES plea
3. detailed information on www phonak com Phonak Australasia Pty Ltd Baulkham Hills N S W 2153 Hansaton Akustische Ger te GmbH 5020 Salzburg Ets Lapperre B H A C NV B 1702 Groot Bijgaarden Phonak Belgium NV B 1700 Dilbeek CAS Produtos Medicos S o Paulo SP 04363 100 Phonak Canada Limited Mississauga Ontario L5W 0B3 Phonak Shanghai Co Ltd Shanghai City 200233 Phonak Danmark A S Nitivej 10 2000 Frederiksberg Phonak France SA 69500 Bron Phonak GmbH 70736 Fellbach Oeffingen EC Representative Phonak India Pvt Ltd 100 034 New Delhi Phonak Italia S r l 20159 Milano Phonak Japan Co Ltd Tokyo 101 0044 Phonak Middle East 11181 Amman Phonak Mexicana S A de C V 03920 M xico D MEXICO Phonak B V 3439 ME Nieuwegein Phonak New Zealand Ltd Takapuna Auckland 9 Phonak AS 0105 Oslo Phonak Polska SP Z 0 0 00 567 Warszawa Phonak Ib rcia S A 03008 Alicante Spain Russian Federation Spain Sweden Switzerland Turkey United Kingdom USA Independent general distributors Manufacturer Phonak CIS Ltd Moscow 115114 Phonak Iberica S A 03008 Alicante Phonak AB 117 43 Stockholm Phonak AG Phonak Schweiz 8712 St fa Phonak Turkey A S 34357 Istanbul Phonak UK Limited Warrington Cheshire WA1 1PP Phonak LLC Warrenville IL 60555 3927 A complete list of Phonak distributors is available at Phonak s Internet site www phonak com Please visit us or ask your hearing care profes
4. dome and gently push the dome into your ear canal The dome should be placed far enough into the ear so that the wire of the xReceiver lies flush with your head 3 Closed domes The closed dome consists of two fins overlapping each other Before inserting the closed dome into the ear canal it is important to check the position of these fins The bigger fin must be positioned over the smaller fin see picture T If the position is incorrect you can easily adjust it With one finger just bend smoothly the bigger fin forwards and then back again so that it is overlapping the smaller one see picture 3 Make sure also that the slit of the closed dome is in a horizontal position on the tube unit as shown in picture T Your xReceiver with closed dome is ready to be inserted into the ear refer to page 13 In very rare cases the dome can remain in the ear canal when removing the Receiver Unit from the ear In the unlikely case that any parts remain in the ear canal it is strongly recommended to see a medical specialist for safe removal 15 Preparation Correct position T Wrong position 2 Moving the fins 3 Inserting Aud o YES with Shell Using the hand on the same side you wear your hearing system grasp the shell between your thumb and index finger Raise your hand to your ear making sure the canal end of the shell faces your ear Tilt your hand slightly forward 17 Pre
5. he interference by one or more of the following measures m Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver m Connect the equipment into an outlet on a circuit different from that to which the receiver is connected m Consult the dealer or an experienced radio TV technician for help 37 38 CE The CE symbol is a confirmation by Phonak AG that Audeo YES products and accessories meet the requirements of directive 93 42 EEC on medical devices and the R amp ITE Directive 1999 5 EC on Radio and Telecommunication Terminal Equipment The numbers after the CE symbol are the numbers of consulted certified bodies under the above mentioned directives The alert sign means that potential restrictions on its use are applicable in one or more EU Member States X This symbol indicates that Aud o YES products comply with requirements for a BF type applied part according to EN 60601 1 The surface of the hearing system is specified as applied part type BF This symbol indicates that it is important that the user refers to associated warnings given in this user guide Safety notice External devices may only be connected if they have been tested in accordance with corresponding IECXXXXX standards Only use accessories approved by Phonak AG Operating conditions The product has been designed for trouble free operation without restrictions when used as inte
6. ional can tell you whether the Microphone Protector should be exchanged or not 27 28 Maintenance Important Consult your Aud o YES specialist about changing the Microphone Protector if you experience any of the following Audeo YES sounds quieter than usual There is a reduction in sound quality Understanding in noise becomes more difficult It becomes more difficult to determine the direction of sounds Important points 1 2 3 4 Always use new batteries for your Aud o YES hearing system You can return empty batteries to your hearing care professional When your hearing system is not in use leave the battery compartment open to allow any moisture to evaporate If you will not be using your hearing system for a long period of time store it in its protective case Remove the batteries and leave the battery compartments open Make sure your hearing system is completely dry before closing the case Protect your hearing system from excessive moisture and heat Always remove it before showering bathing or swimming Do not leave the hearing system near windows or in a car Avoid strong jolts and vibration 29 30 6 7 8 Daily cleaning and the use of a drying system is highly recommended C amp C line from Phonak is a complete set of cleansing products Your hearing care professional will be glad to advise you Never use household cleaning products washing powder soap etc to clean
7. ized volume setting Audeo YES III does not have this function 24 iCom optional iCom is an optional accessory available for Aud o YES hearing systems Automatically or with the push of a single button iCom connects your hearing system with the technology around you Bluetooth connections iCom offers a simple way to connect your mobile phone via Bluetooth to your hearing system iCom is also capable of transmitting a stereo audio signal from any Bluetooth enabled device built in or via an adapter such as MP3 players laptops computers or televisions 25 26 EasyAudio and EasyBluetooth Your Aud o YES hearing system contains two special audio programs EasyAudio and EasyBluetooth These programs are automatically selected in your hearing system when an audio or Bluetooth signal is received from iCom EasyAudio and EasyBluetooth ensure that you have the optimum program activated for streaming An acoustic signal in your Audeo YES hearing instruments confirms the switch to either Easy program Please refer to the iCom user guide for more information on the numerous iCom applications Maintenance Microphone Protector Important The Microphone Protector is an exclusive Phonak system designed to protect the Aud o YES high tech microphones from debris The Microphone Protector can be replaced if needed Your Aud o YES instruments should not be used without the Microphone Protector Your hearing care profess
8. nded unless otherwise stated in this user guide Transportation and Temperature should not exceed limits of storage conditions 20 60 Celsius at a relative air humidity of 65 for extended periods during transportation and storage Air pressure between 500 and 1100 hPa is not detrimental to the instrument Z999 Australia amp New Zealand Yy 3L Brazil 9x CMII ID China ER Japan South Korea ce 0459 39 fice a gt pansasa S1YbU y 9Y XEUOUd o puepiaziMs U payud M Y TL 8007 00 LA ZO E800 670 www phonak com
9. ning of your system We recommend that you remove them before undergoing X ray procedures and keep them outside the room Hearing systems in directional microphone mode reduce mainly background sounds Warning signals coming from behind and vehicles horns approaching from behind are partially or completely suppressed Changes or modifications made to this equipment not expressly approved by Phonak are not allowed 32 ice and Warranty Phonak offers you a comprehensive global warranty which becomes effective on the date of purchase Please ask your hearing care professional about the details and duration This warranty covers any repairs due to defects in material and or workmanship The warranty does not cover damage from improper handling or care exposure to chemicals immersion in water or undue stress Damage caused by third parties or non authorized service centers renders the Phonak warranty null and void This warranty does not include any services performed by a hearing care professional in their office This warranty applies to the Phonak products listed below Serial number Serial number instrument right instrument left Date of purchase Date of purchase 33 Phonak distributors worldwide Group companies Australia Austria Belgium Brazil Canada China Denmark France Germany India Italy Japan Jordan Mexico Netherlands New Zealand Norway Poland Portugal 34
10. paration Insert the canal end of the shell into your ear canal Tug gently on your ear lobe and push the hearing system into the correct position 2 A Now position the hearing system behind your ear Be careful not to twist the tubing 3 Check the placement of the shell by tracing the contour of the ear with your finger 19 Operation Switching On Off Switching Off Using the nail grip slightly open the battery cover until it snaps into its OFF position Switching On Close the battery compartment by pressing on the base of the instrument 20 Please be aware of that your hearing instrument takes several seconds to boot up Your hearing care professional may have activated a further delayed activation timer This function delays the activation of the hearing system for 9 or 15 seconds after the battery door is closed in order to avoid any disturbance while placing it on your ear An acoustic signal confirms when your hearing system is switched on 21 22 myPilot optional The myPilot command center is an optional accessory for Aud o YES hearing systems It allows a convenient user friendly and discreet control of all the functions of your hearing system and additional benefits Volume control Program selection Automatic mode selection Access to ZoomControl program Clock and alarm myPilot battery status Read out of hearing instrument volume programs
11. ry Handle the battery compartment with care and do not use excessive force If there is any resistance when shutting the compartment ensure that the battery is inserted correctly The compartment may not close properly if the battery is upside down and the instrument will not work When your Aud o YES is not in use leave the battery compartment open to allow any moisture to evaporate Low battery warning An acoustic signal gives you an early warning that the battery is approaching exhaustion Usually you have at least 30 minutes to replace the battery With very high quality batteries this reserve may be much higher and Aud o YES will repeat the low battery warning approximately every 30 minutes Please note that the battery consumption increases with regular use of the myPilot command center or the iCom communication interface 11 Preparation Identifying left and right Aud o YES It is important to use the correct Aud o YES for each ear Your hearing care professional can mark them for you with a color code placed in the battery compartment The color code is visible when the battery compartment is opened It will identify left and right instruments as follows blue red left Aud o YES right Aud o YES Inserting Aud o YES with xReceiver and dome into your ear Open domes Place the Aud o YES over the top of your ear 1 Preparation Hold the xReceiver where it attaches to the
12. se visit www phonak com Phonak life is on Description Aud o YES with xReceiver and dome Microphone inputs with Microphone Protector Battery compartment with On Off switch xReceiver Unit Retention optional Dome 686 Aud o YES with xReceiver and SlimTip D See below Individual SlimTip 5 Removal handle Aud o YES with xReceiver Shell for custom fit D Microphone inputs with Microphone Protector Q Battery compartment with ON OFF switch Q xReceiver Unit sound output xReceiver Shell Description Protective case A special protective case is provided to securely store your Audeo YES instruments and batteries Store your Aud o YES in their protective case when not in use and leave the battery compartment in the OFF position as described on page 20 to allow any moisture to evaporate Remove the batteries if you will not be using them for an extended period of time D Left Aud o YES 3 Spare batteries Q Right Aud o YES Preparation Replacing the battery Using the nail grip open the battery compartment completely and remove the old battery Remove the protective foil from the new battery Wait for two minutes before inserting it Preparation Insert the new battery with the sign flat side of the battery in line with the correct battery orientation marked in the battery compartment and close it Replacing the batte
13. sional for information Phonak AG Laubisr tistrasse 28 CH 8712 St fa Switzerland 35 Notices Notice 1 This instrument is certified under FC FCC ID KWC WHSSAN IC 2262A SAN This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications made to this equipment not expressly approved by Phonak may void the FCC authorization to operate this equipment Notice 2 This Class B digital apparatus complies with Canadian ICES 003 36 Notice 3 This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct t
14. your hearing system Hair spray face creams and make up can damage hearing systems Remove the hearing system before applying cosmetics If you experience any soreness or inflammation in or behind your ear contact your hearing care professional If your hearing system fails to operate after you have correctly inserted new batteries contact your hearing care professional for advice Please remember to bring your accessories e g myPilot iCom together with your hearing system for service enquiries A The symbol with the crossed out disposal bin indicates that this hearing system shall not be treated as household waste Please hand over your old or unused hearing system to the applicable collection point for the recycling of electrical and electronic equipment or bring it to your hearing care professional for appropriate disposal By ensuring this product is disposed of correctly you will help prevent potential negative effects on the environment and human health 31 Hearing system batteries are toxic when swallowed Keep them out of reach of children and pets If batteries are swallowed please seek the advice of a medical practitioner Only use hearing systems that have been specially programmed for you by a hearing care professional Other instruments may be ineffective and may in certain cases even damage your hearing Q X ray radiation e g CT scans MRI scans may adversely affect the correct functio