Home
USER MANUAL - J.P. Leisure
Contents
1. chase in relay pattern forward amp Speed 00 99 Flash 00 99 reverse Speed amp Flash adjustable Speed 00 99 Flash 00 99 Speed amp Flash adjustable Seven colour chase from centre to sides Speed 00 99 Flash 00 99 Speed amp Flash adjustable FLOW 8 Two colour chase forward Speed 00 99 Flash 00 99 Speed amp Flash adjustable 1 BLA RGB 2 BLA RGB Blackout Red Yellow Green Cyan Blue Purple White Two colour chase forward amp reverse FLOW 9 Speed amp Flash adjustable Speed00 99 Flash 00 99 BLA Blackout R Red RG Yellow G Green 1 BLA RGB 2 BLA RGB GB Cyan B Blue BR Purple RGB White STAGE COLOR 24 TRI DMX PROGRAMME CHARTS 6 channel mode DMX chart Blackout Blackout__ Blackout 11 21 Master dimmer Flash All Red All Green All Blue 0 255 0 255 LEDs LEDs LEDs 0 255 0 255 0 255 ee oc ME 22 932 Red Flash 0 255 33 43 Yellow Flash 0 255 44 54 Green Flash 0 255 55 65 Cyan Flash 0 255 66 76 Blue 0 5 77 87 Purple Flash 0 255 88 8 White Flash 0 255 99 109 Dream Speed 0 255 Flash 0 255 110 120 Meteor Speed 0 255 Flash 0 255 121 131 Fade Speed 0 255 Flash 0 255 132 142 Change Speed 0 255 Flash 0 255 143 153 Flow 1 Speed 0 255 Flash 0 255 154 164 Flow 2 Speed 0 255 Flash 0 255 165 175 Flow 3 Speed 0 255 Flash 0 25 176 186 Flow 4 Speed
2. 0 255 Flash 0 255 187 197 Flow 5 Speed 0 255 Flash 0 255 198 208 Flow 6 Speed 0 255 Flash 0 255 209 219 Flow 7_ Speed 0 255 Flash 0 255 isd 220 230 Flow 8 Speed 0 255 Flash 0 255 select 231 241 Flow9 Speed 0 255 Flash 0 255 select 242 255 Speed 0 255 Flash 0 255 Sound active Note that from address 0 10 and 22 255 also applies to DMX channel modes 9 12 and 21 STAGE COLOR 24 TRI DMX PROGRAMME CHARTS 9 channel mode DMX chart Flash 0 255 R1 G1 B1 R2 G2 B2 12 channel mode DMX chart Flash 0 255 R1 G1 B1 R2 G2 B2 R3 G3 B3 18 channel mode DMX chart eee ed 21 channel mode DMX chart 11 21 Master Flash Dimmer 0 255 R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 0 255 CH16 CH17 CH18 CH19 CH20 CH21 pe fo fe fm e e STAGE COLOR 24 TRI DMX SET UP DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked togethe
3. 5 ee LA I N ee 4 S g STAGE COLOUR 24 TRI Order code LEDJ108 USER MANUAL STAGE COLOR 24 TRI SAFETY WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty STAGE COLOR 24 TRI SAFETY IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative la
4. USER SERVICEABLE PARTS WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property STAGE COLOR 24 TRI INTRODUCTION Introduction Features DMX channels 21 18 12 9 6 selectable 24 Ultra Bright 3W Tri colour LEDs Sound control via internal microphone 14 built in programmes e Master Slave functions e Auto run mode e Consumption 100W e Beam 25 degrees Overview LCD DISPLAY SS q MODE ENTER UP DOWN STAGE COLOUR 24 27 www prolight co uk POWER SUPPLY CC x AB O Setup Operating Instructions The Stage Color 24 Triis a DMX 512 controllable unit made up of high efficiency and Ultra Bright Tri colour LEDs and will operate in stand alone master slave sound activated or DMX control modes 3 STAGE COLOR 24 TRI OPERATION MODES Operation modes Sound Active mode To activate the unit in sound active mode press the MODE button to show SOUND MODE on the LCD screen Now press the ENTER button to select the desired sensitivity level by usi
5. and erratic behaviour common DMX 512 in 3 pin XLR DMX 512 out 3 pin XLR XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 2 Ground Q Pin 2 Negative 3Hot 3 Hot 3 Postive FIGURE 3 FIGURE 2 Special Note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems interferance it is always advisable to connect DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conversion 5 XLR socket Pin 1 rein aS 3 Pin XLR socket R Pin 1 GND screen Pin 2 Signal Pin 3 Signal 9 5 XLR socket 3 Pin XLR socket Pin 1 GND screen Pin 1 GND scteen Pin 2 Signal Pin 2 Signal Pin 3 Signal Pin 3 Signal in 4 Pin 5 NIC STAGE COLOR 24 TRI TECHNICAL SPECIFICATIONS Technical Speci
6. bels from the equipment Do not open the equipment and do not modify the equipment Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220v 240v Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO
7. fications Weight amp Dimensions GU sich tec ec ch ec es ce cence ceca 390mm SWIAT een eee 165mm dull ene ee 160mm dli m 9Kgs Power SAC WIPE pcm 240V 50hz e Power consumption pp 100W e Fuse Ia F2A Control amp Programming Data rc Locking 3 XLR male socket aeaee Locking 3 pin XLR female socket dimisi D wav ccanavesesuweseestenn DMX 512 UTSITT e DMX 21 18 12 9 and 6 10 CREATE THE RIGHT EFFECT www prolight co uk
8. ng the UP and DOWN buttons Press the ENTER button again to select the frequency level and adjust by using the UP and DOWN buttons SENS 00 31 00 low 31 high FQN 01 99 01 low 99 high Auto run mode To activate the unit in auto run mode press the MODE button to show AUTO RUN on the LCD screen Now press the ENTER button to select the desired frequency level by using the UP and DOWN buttons FQN 01 99 01 low 99 high Note In this mode it will run 13 built in programmes in a continious loop Slave mode To activate the unit in slave mode first you must link multiple units together and press the button to show SLAVE on the LCD screen Now on the master unit press the button to select the desired mode and the slave units will now in sequence with the master unit Built in programmes To activate the units built in programmes press the MODE button to show 01 STATIC on the LCD screen Press the ENTER button to choose between the 14 built in programmes by using the UP and DOWN buttons Now press the ENTER button to select the desired speed and adjust by using the UP and DOWN buttons Press the ENTER button once more to select the desired flash value and adjust by using the UP and DOWN buttons Speed values 00 99 00 slow 99 fas
9. r and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation The Stage Color 24 Tri can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote 10 2M CABL11 5M 12 10M Also remember that DMX cable must be daisy chained and cannot be split STAGE COLOR 24 TRI DMX SET UP Notice Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit
10. t Flash values 00 99 00 slow 99 fast For the 14 built in programmes please see page 5 DMX mode To activate the unit in DMX mode press the MODE button to show DMX MODE on the LCD screen Press the ENTER button and select the desired DMX address setting by using the UP and DOWN buttons Then to select one of the 4 DMX modes 27 15 9 or 6 channel press the ENTER button again to choose the desired DMX mode by using the UP and DOWN buttons For the 21 18 12 9 and 6 channel DMX address information please see pages 6 amp 7 NOTE Once the desired settings have been selected in each of the above modes ALWAYS confirm the settings by pressing the ENTER button 4 STAGE COLOR 24 TRI BUILT IN PROGRAMME CHART 14 Built in programme chart BLA Blackout R Red RG Yellow G Green STATIC COLOR GB Cyan B Blue BR Purple RGB White BLACKOUT RGB Flash speed adjustable Flash00 99 Speed 00 99 Flash 00 99 Speed amp Flash adjustable Speed 00 99 Flash 00 99 Speed amp Flash adjustable Speed 00 99 Flash 00 99 Speed amp Flash adjustable Speed 00 99 Flash 00 99 Speed amp Flash adjustable Seven colour chase forward Speed 00 99 Flash 00 99 Speed amp Flash adjustable Seven colour chase forward amp reverse Speed 00 99 Flash 00 99 Speed amp Flash adjustable Seven colour fade chase in relay pattern forward Speed 00 99 Flash 00 99 Speed amp Flash adjustable Seven colour fade
Download Pdf Manuals
Related Search
Related Contents
Nostalgia Electrics HDR-565 Use and Care Manual Blaupunkt Alaska DJ52 User's Manual Lire l`article complet "取扱説明書" 望月幸義著 『「考え方」 を変える Transition Networks TN-CWDM-10G-1470-80 network transceiver module Philips AVENT Baby monitor SCD505 Progress Lighting P3985-09 Installation Guide Copyright © All rights reserved.
Failed to retrieve file