Home

Model 2600-KIT Screw Terminal Connector Kit

image

Contents

1. as well as damage to the equipment Figure 2 Typical instrument connector Category SMU connection O0000000 CE OMAT CHANNEL B DIGITAL VO 4 KEITHLEY f i RS 232 Zo Ona co oO
2. KEITHLEY Keithley Instruments Inc Model 2600 KIT 28775 Aurora Road Screw Terminal Connector Kit Cleveland Ohio 44139 440 248 0400 www keithley com Introduction This document contains information on the Model 2600 KIT Screw Terminal Connector Kit The kit con tains a cable housing and an inverted plug Use this kit to cable Category SMU output connections on the rear panel of a Model 260x Series SourceMeter Instrument to DUTs Devices Under Test WARNING Maximum floating common mode voltage for an SMU is 250V Exceed ing this level could damage the instrument and create a shock hazard Using an external source to float an SMU could create a shock hazard in the test circuit A shock hazard exists whenever gt 42V peak is present in the test circuit NOTE If applicable remove terminal block s before using the Model 2600 KIT The Model 2602 can use two terminal blocks one for each SMU channel the Model 2601 has one terminal block for the single SMU A terminal block can be removed from the rear panel by loosening the two captive retaining screws and pulling it off the rear panel Connector description The inverted plug secures cables to pins for a quick connection to the rear panel SMU connector Refer to Table 1 for plug specifications Table 1 Plug specifications Characteristic Specification Insulation Material Group Nominal Current Cross Section Maximum Load Current Cross Section Conn
3. ection Capacity UL and CSA Approval Data Nominal Voltage Current Conductor Sizes 12A 2 5mm 2 12A 2 5mm 24 12AWG 250V 12A 24 12AWG PA 907 Rev A 04 05 The green cable housing provides for cable diameters of 6 13 5mm Marker strips and a transparent label carrier are included Use supplimentary insulation as applicable To cable a connector refer to Figure 1 Determine wiring requirements and pinouts see Table 2 Split cable housing into upper and lower halves Loosen strain relief screws Thread wire and cabling into housing through strain relief Connect wires to the inverted plug Make connections to the applicable screw terminals for the determined wiring requirements Snap housing halves together Secure cable with strain relief E a a No Figure 1 Connector assembly Top View Side View Strain relief Screw Screw terminals Inverted plug Table 2 Connector pinouts Pin No Connector Figure LO Sense LO G HI ONOOaR WD qQ Sense HI Connection Refer to Figure 2 for a typical instrument connector location Refer to the specific instrument s user manual for additional connection information WARNING Do not exceed the voltage rating for the wiring used or for the Model 260x Make sure connections at both ends do not exceed the rat ed specifications Failure to follow this warning may result in injury from electrical shock

Download Pdf Manuals

image

Related Search

Related Contents

français  LD ・ 洋室 - 東急不動産の住まい  Acァダブタをコンセントに差し込み、 源を入れる    M-Cab 20m HDMI /Amplifier A  Raccomandazioni importanti  オーナーズマニュアル  Zebra P640i User's Manual  BlackBerry Q5 8GB 4G Black    

Copyright © All rights reserved.
Failed to retrieve file