Home
SIARETRON 1000 IPER
Contents
1. SIARETRON 1000 IPER Intensive care ventilator FOR HYPERBARIC CHAMBER Gas driven Adults Paediatric Newborns codice 960069 rev del 05 11 2014 Main characteristics The Siaretron 1000 IPER has been designed to work in hyperbaric chamber up to 60m depth The ventilator electronic lung ventilator is equipped with a TFT 9 colour monitor displaying the curves of pressure flow volume the loops of breathing parameters the trends and the ventilatory parameters The ventilator is suitable for ventilation of adult paediatric and neonatal patients It is equipped with a flow and pressure trigger it provides the most advanced volume controlled ventilation modalities VC VAC VC VAC BABY pressure controlled ventilation modalities APCV APCV TV SIMV by Volume and by Pressure Pressure supported modalities PSV PSV TV CPAP BILEVEL S ST SIGH Non Invasive Ventilation NIV Drug Nebulizer and Manual Ventilation MAN Siaretron 1000 IPER is supplied with back up long lasting batteries and its software can be updated for new modes and last generation ventilatory strategies Dimensions Weight Relative Humidity use Working temperature Flow compensation up to 60m depth Flow compensation with HELIOX Siaretron 4e IPER te Ventilator unit 266 x 244 x 174 mm W x H x D Ventilator unit 5 5 Kg 30 95 RH From 10 to 40 C Automatic Automatic 1 8 Use destination Operation principle
2. Ventilation modalities Breathing rate Inspiratory Time Expiratory Time maximum minimum SIMV Breathing rate SIMV Inspiratory time Tidal volume I E ratio Inspiratory pause Inspiratory pressure limit PEEP Oo concentration Trigger Trigger E Trigger detective method Max inspiratory flow Siaretron 4e IPER te High performance Intensive care ventilator for adults children and newborns with colour TFT at 9 e Time cycled at constant volume e Pressure cycled e Microprocessor controlled flow e Spontaneous breath with integrated valve VC VAC VC VAC BABY APCV BILEVEL ST APCV TV P SIMV PS V SIMV PS SPONT PSV BILEVEL S PSV TV Auto Weaning APRV CPAP SIGH NEB Apnoea BACK UP NIV MANUAL From 5 to 150 bom e Timin 0 036sec minimum inspiratory time e Ti max 9 6sec maximum inspiratory time e Temin 0 08sec minimum expiratory time e Te max 10 9sec maximum expiratory time From 0 to Rate 1 Rate 1 From 0 2 to 4 0 sec from 2 to 3000 ml from 2 to 100 ml in VC VAC BABY mode From 1 10 to 4 1 From 0 to 60 of the inspiratory time From 2 to 80 cmH20 From OFF to 50 cmH20 Adjustable from 21 to 100 with electronic integrated mixer Automatic safety function to decrease O2 concentration for depth greater than 2 2bar O2 50 or greater than 5bar O2 21 e Pressure trigger adjustable from OFF 1 to 20 cmH20 under PEEP level e Flow trigger adjustable from OFF 0 3
3. INEERING INTERNATIONAL GROUP s r l Via Pastore 18 Localit Crespellano 40053 Valsamoggia BO ITALY Tel 39 051 969802 Fax 39 051 969366 Email mail siare it http www siare it Siaretron 4e IPER te 8 8
4. ange 0 3000 ml e Minute Volume range 0 40 l min e Inspiratory Peak Flow range 1 200 l min e Expiratory Peak Flow range 1 150 l min MAP cmH20 Pplateau cmH20 Fi L min Fe L min Ti sec Te sec Tpause sec Ri mH20 L sec Cs ml cemH20 e CURVES Pressure Flow Volume CO2 optional e LOOPS Pressure Volume Flow Volume Pressure Flow e Auto range Storage capacity 72 h of all measured parameters Memory storage up to 100 machine events including the alarms e Magnetic perturbance patented multi usage e Automatic flow sensor calibration started by the operator e Steam or chemical disinfection Electronic with automatic calibration 5 8 Alarm types With limits set by the operator By default the operator cannot set them up Alarm priority High Mean Standby Airways pressure High Low Breathing rate High Low Expired Minute Volume High Low Expired Tidal Volume High Low FiO2 concentration High Low PEEP High Low Electric power supply Alarm occurs in case of failure of external power supply Apnoea Low Rate function of Apnoea BACK UP Level charge Battery at 50 Level charge Battery at 25 Battery Level low 10 Minutes Gas feeding O2 Low lt 2 7 bar Gas feeding Air Low lt 2 7 bar CAN BUS error Electronic boards CAN connection wrong Maintenance 1000 hours Gas supply Verification of the presence of Air and O2 suppl
5. ck date and time functions Visualization of software version 3 8 Display keyboard Lateral keyboard for rapid access of functions Encoder knob for selection set up and confirmation of physiological breathing parameters selection and direct activation of function Set physiological breathing FLOW L min FR bom FRsimv bpm E Pausa PEEP cmH20 parameters SET PLIM cmH20 PMax cmH20 PS cmH20 SIMV RATE bpm Ti s Ti max s Ti min s Trig E Trig L min Vte ml Vti ml O2 SIGH bom CPAP cmH20 APRV sec cmH20 BACK UP parameters MENU function settings SETUP function settings Siaretron_4e_IPER_te SETUP adjustments Alarms Trends Events Patient data Default parameters Language Graphic Volume Energy saving Brightness Apnoea time Gas sensor N20 unit of measurement Password TCP setting Technical contact Test on demand Gas sensor Colour selection 4 8 Measured parameters Additional measured parameters Displayed graphics Trends Events Flow sensor Oxymeter Siaretron 4e IPER te e PAW peak mean plateau PEEP range 20 80 cmH20 e Tinsp Texp Tpause range 0 036 10 9sec e E ratio range 1 99 99 1 e Static and dynamic compliance range 10 150 ml cmH20 e Resistance range 0 400 cmH20 1 s e of FiO range 0 99 e Rate range 0 150 bpm e Tidal Volume Vte Vti r
6. to 15 l min From 5 to 90 of the inspiratory flow peak Through sensor pressure or flow 240 min 2 8 Flow by Leakage compensation SIGH APRV CPAP NEB Supply pressure Patient circuit Other controls Other features Expandability Dead space compensation 9 TFT colour display Siaretron _4e IPER te 2 I min Flow Trigger In NIV mode Interval 40 500 bpm step 1 Amplitude OFF 10 100 of set Tidal Volume step 10 Time 1 and Time 2 from 10 to 200 sec Level 1 and Level 2 from 3 to 30 cmH20 From 3 to 30 cmH20 Drug nebulizer selectable to 6 l min with automatic compensation on forced ventilation modes and dedicated output Oo Aria pressure included between 280 kPa and 600 kPa 2 8 6 bar Max flow requested from ventilator 120 l min Double hose non rebreathing INSP Block and EXP Block max 20 seconds Button 100 O2 x 5 min MAN control manual ventilation Loops e Curves selection External alarm Nurse call Software upgradeable for future modalities Automatic compensation of mechanical and patient circuit dead space The display allows Setting of Operative Mode Visualization of alarm messages and signals Setting and monitoring of physiological breathing parameters Visualization of additional graphs and breathing parameters The function MENU for setting operation parameters Activation of special functions Visualization of operative mode clo
7. y pressure EXP INSP Flow sensor Verification of EXP flow sensor operation Airways pressure sensor Verification of pressure sensor operation through control of PAW reading Patient circuit Verification of patient circuit Battery Checking on battery power Oxygen cell Cell condition Acoustic alarm Verification by the user of acoustic signal emission the confirmation of the test is made by silencing of that alarm Siaretron 4e IPER te 6 8 Electric power supply 100 240 Vac 47 63Hz 150W for usage outside hyperbaric chamber DC power supply 12Vdc 150W for usage inside hyperbaric chamber Power 55 Watt Internal power supply 12 Vdc 4 5 Ah Internal battery operation 120 min maximum Re charging time About 8 hours External connections RS232 for PC transfer patient data events and trends excell format ISO 5369 EN 1281 1 IEC 601 1 IEC 601 1 2 Directive 93 42 EEC EN 4135 IEC 601 1 4 NF S 90 118 EN 794 1 UNI CEI ISO 14971 UNI EN 475 UNI EN ISO 9703 3 Class and type according to IEC 601 1 Class 1 Type B Class according to 93 42 EEC Directive Class IIb Supplied Accessories e User s Manual e O92 supply hose e AIR supply hose e Nebulizer set e Silicone patient circuit e Antibacterial filter e Power cable SHUKO VDE e Oo cell Optional Accessories See on Export Price List Siaretron 4e IPER te 7 8 266 1 250 7 SIARE applies the UNI EN ISO 13485 2004 Quality System and the 93 42 EEC SIARE ENG
Download Pdf Manuals
Related Search
Related Contents
User`s Manual - Gene-Foci Guia do Usuário Mini Speaker Mode d emploi Operação Powerplus POW4060 power sander 参考 - カー用品&タイヤ・ホイール卸値販売【DAC】 J- Wing Therma-Stor Products Group TS-285 User's Manual TVS-spanish_portuguese_greek_danish 771072024 Rev04 Samsung 223BW Керівництво користувача Copyright © All rights reserved.