1. any other wiring through the cable entry cutout before fastening the rear casing to the mounting surface Refer to Installation template supplied opposite Install the rear casing using three countersunk screws or bolts The Tamper Switch actuating lever may also be fastened to the mounting surface to provide an enhanced level of cabinet tamper detection Do not overtighten as this may cause the lever to dig into the mounting surface and limit its ability to actuate the Tamper Switch Connect the wiring into the Screw Terminal block and fit or remove the Termination link TERM as required See pages 4 amp 5 for details Position the three tabs at the top of the front casing into the slots at the top of the rear casing then gently press the two halves together until the locking tabs on the sides and at the bottom of the case engage 4 Prisma Colour Graphic Terminal Installation Manual Connections amp Link Options CAUTION Take care not to damage PCB tracks the components around the Screw Terminals or the LED light pipes at the top of the unit during installation TERM LAN OV LANA LANB EIX ERX ETX ERX Connection for field firmware upgrades and future expansion board LAN Connections See following page for information TERM LAN Termination This link is fitted if the Terminal is one of the two furthest modules on the LAN or a LAN Isolator See Concept 4000 Installation manual or LA
2. N Installation amp Troubleshooting for more details If LAN Isolators Fibre Modems or CLOE units are used each isolated section of the LAN is treated as a separate LAN system when terminating modules Rev 2 0 May 2012 LAN Wiring The LAN is connected using twisted pair communications cable Connect LANA amp LANB using one pair LAN amp OV with another pair A amp B must be on the same pair Over longer distances use heavy duty Figure 8 cable for LAN amp OV or use a separate local power supply Cabling distance should be no more than 1 5km from the Control Module a LAN Isolator LAN 2 or 3 Port or a Fibre Modem RS485 Port LAN not connected if Terminal powered from external Power supply Auxiliaries and LEDs fee ooo eee LAN OV LANA LANB ETX ERX x AB AB From To next Previous module module There are no physical Auxiliary outputs available on a Prisma Terminal Auxiliaries are used for the following indicator control functions T X01 Aux 1 Not used Spare for future option T X02 Aux 2 Not used Spare for future option T X03 Aux 3 LED5 T X04 Aux 4 Pulse Beeper option T X05 Aux 5 Siren Continuous Beeper option See Resource Configuration on page 8 T X06 Aux 6 LED 6 T X07 Aux 7 LED 7 T X08 Aux 8 LED 8 LED Number 1 2 3 4 a OF inner range 6 Prisma Colour Graphic Terminal Installation Manual Access Control via a Prisma
3. Rev 2 0 May 2012 1 Concept 4000 Prisma Colour Graphic Terminal Part Number 995060 Installation Manual The Prisma Terminal is a User interface for the Concept 4000 system It features eight status LEDs a full colour LCD screen built in temperature sensor easy to read text and icon scroll wheel and function key based navigation system The colour and intensity of the Keypad backlighting and Screen colour schemes are configurable and feature auto dimming Audible indications are provided by sophisticated 8 bit digital sound tones and options are provided for Date Time and Temperature on the default display Prisma Terminals can be used in systems to perform programming commissioning and User operations display alarm messages and review system activity They communicate on the LAN as an LCD Terminal Module Type and the module number and configuration options are programmed from the keypad Built in tamper monitoring detects any attempt to open the case or remove the product from the mounting surface Specifications Power Supply Input 11V to 14V DC Operational Current Default Backlight settings Low Ambient Light Approx 55mA High Ambient Light Approx 75mA Custom Backlight settings 50mA to 180mA Beeper Operating Add up to 65mA at maximum speaker volume level Physical dimensions Height 162mm Width 88mm Depth 15mm Enclosure material Polycarbonate Installation environment 0 40 C 15 to 85 relative h
4. Terminal The Prisma Terminal can be used for Door Access Control in PIN Only PIN or Card or Card amp PIN modes to provide the PIN code entry However the following conditions currently apply 1 The Prisma Terminal does not currently support any Inputs or Outputs Therefore any Door to be controlled via a Prisma Terminal must also be associated with a Reader Module and all Inputs and Outputs associated with the Door must be connected to that Reader Module 2 The Lock Auxiliary for the Door must be the Reader Module Lock Auxiliary not the Terminal Lock Auxiliary 3 The Prisma Terminal cannot be connected to the local LAN connection on Intelligent 2 Door 4 Door Access Modules and should therefore not be used to control Doors that are associated with these Modules Commissioning Prisma Firmware V2 0 When installation is complete power up the Terminal The startup screen will display the Module number and Firmware Version and a Config function key This screen will be displayed for 30 seconds or until the lt Config gt or lt END gt is pressed if Tamper switch is unsealed 2 5 seconds if the Tamper Switch is sealed e To view and or change any configuration options press the Config function key while this initial screen is displayed then go to Step 2 below e To exit the startup screen and go to the normal default display press the lt END gt key The default display may show a norma
5. l Diary Area status or Alarm message etc This means that the default Terminal number Set to 01 at the factory has been accepted To change the Module number and or configure the Terminal options go to step I below Alternatively the 1st configuration screen may be displayed with one of the following messages shown just above the function key labels Module number already exists There is already a Prisma other LCD Terminal type with the same address number Module number is too big The module number is too high for the memory size amp or configuration If either of these messages is displayed go to Step 2b below 1 Enable Configuration Mode Power cycle the Terminal then press the lt Config gt key within 30 seconds Or within 2 5 seconds if Tamper switch is sealed Alternatively logon press lt MENU gt then press the lt Config gt FUNCTION key Rev 2 0 May 2012 7 At any time the following keys if displayed may be used lt Back gt function key Scrolls back through the configuration screens lt More gt function key Scrolls forward through the configuration screens lt Exit gt function key Exits config and returns to the normal display lt END gt key Exits config and returns to the normal display 2 Colour Scheme and Terminal Number a Press the lt ON gt key if you wish to change the colour scheme b To change the Module Number choose a number that isn t already used by another Graphic Terminal a
6. nd enter the new number using the lt DIGIT gt keys Use the lt Delete gt Function key to backspace if you make an error Press lt OK gt to save the new Module number NOTE Cannot be edited if Config accessed via the Menu c Press lt More gt for additional configuration options or lt Exit gt 3 Terminal Setup options 2 screens a Use the Scroll Wheel or lt UP gt amp lt DOWN gt Arrows to select the option to change b Press lt ON gt to enable or lt OFF gt to disable the check box type option c If changes are made press lt OK gt to save the changes and step to the next screen 3 1 Audio RFID future enhancement amp Custom Keypad Colour options e Audio auto off The speaker is muted when no audio is present to eliminate background noise This may be preferred in quiet areas e g bedrooms If enabled a short delay may occur between the re appearance of an audio signal and the speaker being un muted e Enable RFID ASK support Not yet available e Enable RFID HID support Not yet available e Enable custom keypad RGB If enabled adjust the RGB values in Step 4 2 e Auxiliary 4 controls Pulse beep e Auxiliary 5 controls Continuous beep Or Siren tone depending on Sound resource file loaded See Resource Configuration on page 8 3 2 Keypress options amp Factory reset e Enable red flash on error e Enable keypress flash e Reset all to factory defaults 4 Terminal Preferences 4 screens a U
7. se the lt UP gt and lt DOWN gt Arrows to select the setting to change b Use the SCROLL WHEEL to change the setting c If changes are made press lt OK gt to save the changes and step to the next screen 8 Prisma Colour Graphic Terminal Installation Manual 4 1 Speaker LCD Backlight and LED level options e Speaker Volume level e LCD Minimum Backlight level In very low ambient light e g A dark room e Indicator LED Minimum and Maximum levels 4 2 Keypad Backlight Levels e Keypad Minimum Backlight level In very low ambient light e g A dark room e Custom Keypad Red Green and Blue levels NOTE These settings only relevant if the Enable custom keypad RGB option is enabled at Step 3 1 4 3 Keypad Colour Mode None Rainbow fast Rainbow slow Flame Water Random 4 4 Keypad Sensitivity e Key sensitivity Use the lt DIGIT gt keys to test while making adjustments Factory default is 120 Return to this setting if unsure e Scrollwheel sensitivity Use lt 4 gt and lt 6 gt keys to adjust and the Scrollwheel to test while making adjustments Use the lt 2 gt key to go back to Key Sensitivity adjustment Factory default is 170 Return to this setting if unsure 5 Resource configuration information The Prisma Graphic Terminal can have alternative sets of Image Sound Text String and Font resources At any given time one of each of these resources is in use in the device The Resource Configura
8. tion screen allows the Installer to view the Currently Loaded Resources files currently in use String and Font files will cater for different languages as they become available Image files will provide alternative sets of bitmaps icons and colour schemes Sounds files will provide alternative sets of sound effects At present Resource Files are factory loaded for the country in which the unit is sold 6 Additional Prisma Terminal programming Other Prisma Terminal options are programmed in LCD Terminal Programming lt MENU3 7 2 1 See the latest version of the Programmer s manual for details NOTE If Multiple Area in the Messages options is set to Yes then Text in the Logged Off options must also be set to Yes Also refer to the Prisma Colour Graphic Terminal User Manual for additional information on the default display Iconic and Text menu displays and the various Graphic screens for control information and programming operations
9. umidity non condensing Control Module Firmware V8 0 or later is recommended Prisma Terminal cannot be used with Control Module firmware prior to V7 99 Beta 2012 Inner Range Pty Ltd Part No 635060 2 Prisma Colour Graphic Terminal Installation Manual Mounting template 88 mm 47 mm Position of LCD Display O Legend O Rear Casing mounting holes Tamper Lever mounting hole 132 5 mm 158 mm 85 5 mm Cable en try cutout 14mm 27 5mm 27 5 mm 55 mm 25 5 mm Rev 2 0 May 2012 3 Installing the Terminal Prisma Terminal Parts List Prisma Colour Graphic Terminal assembly Installation Manual and mounting template This document Installation Choose an appropriate mounting location with a solid flat vertical surface and ensure that the LCD display will be at or slightly below eye level for all users a Remove the rear of the case by first applying gentle pressure to the lower locking tabs in the bottom rear of the case with a small flat blade screwdriver while gently pulling the lower front of the case away from the rear b Then gently pull one side of the front case away from the rear to release the upper locking tabs Check that the mounting surface is free from any materials or irregularities which may distort the case then mark the mounting hole locations Remember to insert the LAN cable and