Home
Daikin AC pdf Sales Bulletin #CT014
Contents
1. 1510 www daikinac com Published by Daikin AC Controls Engineering Department Daikin s products are subject to continuous improvements Daikin reserves the right to modify product design specification and information in this bulletin without notice and without incurring any obligation Page 5 of 5 Wiring outdoor unit not shown Wiresto Daikin Indoor Unit MAIN PCB TERMINAL BLOCK incoming 208 230V ENVi Thermostat Wire Harness 5 4 thermostat wire i I Field Supplied 4 core come within a box l 18AWG 1 250ft 380m I 20AWG 800ft 240m I 22AWG 500ft 150m eel To ENVI 2 wires for power supply 24VAC 2 wires for communication Power Cable F 4 Ee DPCA can beinstalledin the backside cavity of the wall mounted indoor unit if space allows and beside the ducted indoor unit DPCA should notbe installedin plenum D Optional Auxiliary Heater ie jee S 24VAC C R 2wire for power supply 24VAC J i R D D 2 wire for RS485 serial communication Modbus Daikin ENVi Back Plate Daikin AC Americas Inc 1645 Wallace Drive Suite 110 Carrollton TX 75006 972 245 1510 www daikinac com Published by Daikin AC Controls Engineering Department Daikin s products are subject to continuous improvements Daikin reserves the right to modify product design specification and information in this bulletin without notice and without incurring any obligation
2. Heater Only and Primary Heat for Cooling Only system e High Low Temperature Alerts On screen Web Email o Good for server mechanical room application e System Error Alerts On screen Web Email o Error code with plain text explanation User Web Portal Mobile Apps The Daikin ENVi supports Wi Fi connectivity that can be used to monitor and control the Daikin indoor units from the customers PC smart phone and or tablet with internet access This will provide our customer with the ability to monitor and control their Daikin system from where ever they are e User Web Portal access via www DaikinENVi com free of charge e Daikin ENVi apps available for Apple Android and Blackberry devices free of charge V DAIKIN Be ENVi d hag ee Be ENVi d Pee Be ENVi d 3 9 Preference Settings HVAC Operation Report Daikin AC Americas Inc Mobile App 1645 Wallace Drive Suite 110 Apple Android Blackberry a E a www daikinac com Published by Daikin AC Controls Engineering Department Daikin s products are subject to continuous improvements Daikin reserves the right to modify product design specification and information in this bulletin without notice and without incurring any obligation Page 3 of 5 Contractor Web Portal The Daikin ENVi also provides Dealers with a Contractor Web Portal free of charge This is an online tool that makes it even easier for Dealers to provide proactive support to their customers
3. Y DAIKIN AC Sales Bulletin CT014 absolute comfort Date May 13 2013 To Daikin Sales Service and Distribution Subject The Daikin ENVi Thermostat kit DACA TS1 1 Daikin AC is pleased to announce the Daikin ENVi Thermostat kit The Daikin ENVi can be used with the Single Split system Multi Split system 2 8 port and SkyAir FXTS indoor unit Applicable indoor unit models are CTXS FTXS FTXN KRP980B1 interface adapter required for 09 12 J K EVJU CDXS FDXS The Daikin ENVi Thermostats are now available for ordering and shipping will start July 2013 Sales support documents are available on TRL FTP site ia e Installation Manual and User Manual worn co rg og e Sales Preso 74 e Quick User Reference Guide available by end of May gn O e Installation Guide available by end of May Training Classes will cover the Daikin ENVi starting June 2013 See www daikinuniversity com e RLC Product and Application Sales training e RLC Install and Commissioning Commission training Daikin ENVi Thermostat Overview The Daikin ENVi Thermostat is the newest addition to Daikins residential light commercial controls offerings The Daikin ENVi has an easy to read backlit color LCD screen that displays all the information you need Use the navigation buttons to quickly change the temperature access features and configure settings Thu May 2 7 43pm Thu Mar 21 5 07 pm 4 Day Weather Forecast Time Heat Cool Fri Sat Su
4. n Mon HUMIDITY 37 COOL HEAT a a H96 H90 H88 H81 CURRENT TEMP Awake at 6 00am 70 73 L87 L85 L85 L75 Oo Away at 8 00am 65 80 ie SA 3 we shoe Home at 12 00pm 70 73 Feist Ee Mainly Thunder S Partly Sleep at 10 00pm 65 80 Sunny Storm old Cloudy POP 20 POP 80 POP 0 POP 20 Y x Indoor Outdoor Add New HUM60 HUM90 HUM60 HUM 70 Humidity 41 Humidity 55 Save and T a 24Hour Forecast gt i Temperature Setting Ambient Display Weekly Schedule Weather Forecast Daikin AC Americas Inc 1645 Wallace Drive Suite 110 Carrollton TX 75006 972 245 1510 www daikinac com Published by Daikin AC Controls Engineering Department Daikin s products are subject to continuous improvements Daikin reserves the right to modify product design specification and information in this bulletin without notice and without incurring any obligation Page 2 of 5 The Daikin ENVi Thermostat calls for cooling heating based on the room temperature sensed by the thermostat and controls the Daikin indoor unit to maximize the invertor Capabilities The following features are available e Cool Heat and Auto mode with dual setpoints o Adjustable changeover band in Auto mode e Fan On Auto o Minimum Fan On time for improved air circulation o Fan speed and Louver direction e Weekly setback scheduling o Optimum start o Hold Quick save and Vacation settings e AUX heater control o Supplemental heat for Heat Pump Aux
5. rating Range Humidity Operating Range Aux Heater Relay Electrical Rating Power Battery Backup Wirino Wire Specification Thermostat to DPCA Regulatory DPCA Temperature Operating Range Humidity Operating Range Power May 2 7 43pm Y y 3 HUMOITY 37 ORENT TEMP a 14 o 4 J DAIKIN 45 80 F 7 26 5 C 65 95 F 18 5 35 C 40 100 F 5 37 C 1 F 0 5 C J 32 130 F 0 55 C 5 95 R H non condensing 30VAC Max Current 3A 24 VAC 8VA maximum provided from the DPCA CR2032 3V lithium coin cell 18 AWG 20 AWG 1250 ft 380 m 800 ft 240 m FCC Part 15 Class B FCC ID XF6 RS91 10N1102 IC 8407A 91101102 Y DAIKIN ENY I 20 to 90 RH 5 RH Humidity Sensitivity 2 5 full color LCD 320 x 240 pixel resolution 802 11 b g n wireless routers WEP 64 WEP 128 WPA and WPA 2 encryption methods DHCP dynamic or Static IP addressing 168 bit SSL encryption 5 5 X 3 25 x 1 inches 139 5 x 82 5 x 25 mm Display Wi Fi Dimensions WxHxD 22 AWG 500 ft 150 m 20 140 F 7 60 C 5 to 95 R H non condensing 208 230 VAC provided from Indoor Unit Dimensions 4 7 x 2 0 x 1 3 inches W x H x D 120 x 50 x 32 5 mm Fire retardant ABS Plastic CYCOLOY Resin C6200 Regulatory UL 873 certified Daikin AC Americas Inc 1645 Wallace Drive Suite 110 Carrollton TX 75006 972 245
6. which in turn will deepen their relationship with their customers and grow their business Our dealers will be able to easily register their customers on the portal with the serial number sticker provided in the Daikin ENVi Thermostat kit The Dealers will have access to e HVAC Reports o Access customer s HVAC Reports for remote troubleshooting and diagnostics o Items shown on the report are Cool and heat setpoints Room temp and humidity Outdoor temp Operation time ecobee e Alerts Reminders o Notifies Dealer when Alerts Errors are generated on customer s equipment Map shows customer location and Alert Error Count o The HVAC Service maintenance reminder generates an alert telling the dealer that a regularly scheduled maintenance is required o Send branded Service Reminders to their customers based upon their preferred service schedule Daikin AC Americas Inc 1645 Wallace Drive Suite 110 Carrollton TX 75006 972 245 1510 www daikinac com Published by Daikin AC Controls Engineering Department Daikin s products are subject to continuous improvements Daikin reserves the right to modify product design specification and information in this bulletin without notice and without incurring any obligation Page 4 of 5 ENVi Thermostat Setpoint Range Heat Setpoint Range Cool Setpoint Range Display Range Temperature Sensitivity Specifications Maximum Indoor Units Temperature Ope
Download Pdf Manuals
Related Search
Related Contents
Geberit AquaClean Scarica le istruzioni PDF 12. Guía del usuario para la Realización del Trámite de Certificado DESLIZADERA DE SEGURIDAD PARA CUERDA(ES2096897) Datensicherungssoftware, Version 1.0 Operating Instructions VEGAPULS 69 Copyright © All rights reserved.
Failed to retrieve file