Home

Back-Pak HEPA Vacuum Dry 2.5 Gallon User Manual

image

Contents

1. INSTRUCTION MANUAL MODEL BP00288 BACK PAK HEPA VACUUM TWEE a ME PEO INDUSTRIES INC All Nikro Industries Inc products that have rated efficiencies of 99 97 0 3 microns and 99 99 0 3 microns have H E P A filters that have been individually tested to meet these minimum efficiencies Although all the filters have been pre tested the possibility of leaks or filter failure due to handling transportation punctures loaded filters moisture wear and tear etc does exist Therefore when using this equipment in highly sensitive areas or where any release of particles above and beyond the minimum efficiencies would be detrimental and harmful to humans plants or property it is strongly recommended that the units be individually tested prior to their use This is to assure that they are maintaining the efficiency levels which they were designed to filter out FAILURE TO DO SO COULD RESULT IN SERIOUS HARM TO HUMAN LIFE PLANT LIFE AND OR PROPERTY OPERATING INSTRUCTIONS Inspection Thoroughly inspect your machine for any shipping damage Your machine has already been thoroughly tested at the Nikro Industries manufacturing plant prior to shipping Electrical Specification This machine is designed to operate on 15 115V 60 hz AC circuit A deviance of this could cause serious damage to the unit Grounding Instructions This machine is equipped with a grounding type c
2. R 1 9 520329 LOWER MOTOR GASKET 1 10 520465 INLINE CORD SWITCH 1 REFERENCE PART NO DESCRIPTION OTY REO 1 520371 LID 1 2 520018 LID GASKET 1 3 861969 HEPA FILTER 1 4 862006 IPACTION FILTER 1 REFERENCE PART NO DESCRIPTION OTY REO 1 540008 MOTOR AND LID ASSY 1 2 520037 DACRON FILTER BAG 1 3 520033 COLLECTION BAG 1 4 520372 TANK 1 REFERENCE PART NO DESCRIPTION OTY REO 1 520019 LID LATCH 3 2 520372 TANK 1 3 520216 INTAKE GASKET 1 4 520118 INTAKE TUBE 1 5 520220 INTAKE 1 6 520217 INTAKE KNOB 1 7 540009 HARNESS ASSEMBLY 1 861159 HARNESS CORD CLIP 1 NO SHOWN 540007 TANK ASSY W HARNESS COMPLETE 861158 TANK ASSY COMPLETE LESS HARNESS TOOL KIT amp REPLACEMENT PARTS FOR 288 BACKPACK PART NO DESCRIPTION OTY REO 520456 1 X 7 CRUST PROOF HOSE ASSY 1 520112 1 X 3 ROUND DUST BRUSH 1 520457 1 X 5 UTILITY TOOL 1 860930 1 X 20 PLASTIC WAND 2 520111 1 X 9 CREVISE TOOL 1 860940 PLASTIC BRUSH ADAPTER 1 520523 3 REPLACEMENT BRISTLE FOR 520112 DUST BRUSH Nikro equipment is warranted for 2 years from the date delivered to the original purchaser Parts which become defective due to faulty workmanship or materials during normal use in these years will be repaired or exchanged at no charge if returned and approved by an authorized Nikro service center The freight shall be at the expense of the customer This warranty does not apply to normal wear and
3. bjects away from all moving parts and openings on this machine 8 This vacuum cleaner should never be used in explosion hazardous areas or to pick up combustible or flammable liquids such as gasoline etc 9 Never leave the machine unattended when plugged in or running 10 Always have the switch in the OFF position before unplugging the unit 11 Do not operate this machine with any of the openings blocked always keep these areas free of lint and dust or any other particles that could reduce the airflow 12 Never operate or plug in this machine or any other electrical appliance with wet hands or when standing in water 13 This machine should never be operated without the proper filters installed in the manner described in the following pages of this manual 14 This machine should never be serviced by anyone other than an authorized technician 15 Use only original NIKRO replacement parts and attachments TANK AND FILTER PREPARATION 1 Place the paper collection bag into the bottom of tank Pull the cardboard rubber collar over the down tube sliding it over the rib on the down tube Gently pull apart the accordion like pleats so that the bag is open 2 Take the non clinging dacron filter bag and pull the elastic band up over the H E P A filter and let the elastic band rest securely on the H E P A filter 3 Place the lid assembly onto the tank and snap the latches into place FILTER MAINTENANCE AND REPLACEMENT INSTRUCTIONS War
4. ning When a loss of vacuum power is detected the vacuum should be turned off immediately Continued use of the machine could result in severe damage to motor and or H E P A filter This loss of vacuum power could be caused by one of the following a The paper collection bag may be full and needs to be replaced b The hose or down tube may be clogged and needs to be cleared c The dacron filter bag may be clogged and needs to be cleaned The H E P A filter may be clogged and needs to be replaced To prolong the life of the H E P A filter and motor the paper collection bag should be changed when it is either half full or when 7 pounds of debris is collected PROCEDURES FOR REMOVING CONTAMINATED FILTERS Caution When removing contaminated filters or using this machine you should always wear gloves and respirator approved for use with the particular contaminant you are working with FILTER REMOVAL PROCEDURES 1 Turn off and unplug machine 2 Slowly and carefully lift one side of the lid assembly from the tank Holding the lid with one hand reach under the lid and gently tap all around the dacron filter bag allowing any loose dust particles to drop into the tank 3 Carefully lift the lid assembly off the tank With a damp rag wipe underside of the lid assembly Set it aside and dispose of rag properly Note Never set the lid down on the H E P A filter 4 Take the collar of the paper collection bag and carefully slide it d
5. ord and three prong plug Make sure that the plug is connected to an outlet with three receptacles designed for use with the three prong plug See Illustration Never use an adapter with machine Grounding Pin Maintenance Lubrication of this motor is not required as it is equipped with sealed bearings Always keep the air cooling intake screen free not allowing any restriction of airflow Airflow restriction will overheat and damage the motor To prolong the life of the H E P A filter empty clean and replace bags and filters regularly as described in the following sections SAFETY INSTRUCTIONS Read all safety instructions before using 1 Electrical shock could occur if used outdoors or on wet surfaces 2 Always store machine indoors in a dry area If machine is dropped in water or left in rain it should be serviced by an authorized service technician prior to plugging the unit in 3 Prior to plugging in machine always inspect cord for cuts and exposed wires If these problems are found return the machine to an authorized service technician 4 Never use the cord as a handle or pull the machine by using the cord 5 Never unplug this machine or any other electrical appliance by pulling on the cord 6 Do not wrap the cord around the dome Wrapping the cord around the dome will restrict the motor from exhausting properly and will result in overheating and damaging the motor 7 Keep hair fingers and other o
6. own and off the down tube 5 Carefully remove the collection bag from the tank and dispose of properly 6 Take a damp rag and wipe down the inside of the tank Dispose of the contaminated rag properly 7 All hazardous waste must be disposed of properly Never put contaminated debris in a regular trash container All debris must be placed in a plastic bag or container labeled Hazardous Materials and should be removed by a licensed waste hauler CONSULT PROPER AUTHORITIES FOR REGULATIONS REGARDING DISPOSAL 1 2 3 4 5 6 PROCEDURE FOR CHANGING THE HEPA FILTER The precautionary steps described in this manual should be used when changing the HEPA filter NOTE You must follow Local and 1 or Federal guide lines when working with contaminated filters Remove the eight 8 bolts holding the HEPA filter to the lid assembly using a Phillips screw driver and an 11 32 wrench Carefully remove the HEPA filter being careful not to create any airborne dust This filter cannot be cleaned and should be disposed of in an appropriate manner Re install the new HEPA filter using 8 screws nuts lock washers and flat washers 63 03 3 LAAs Comm Com REFERENCE PART NO DESCRIPTION QTY REQ 1 860181 DIFFUSER 1 2 860809 DIFFUSER CLAMP 1 3 860179 DIFFUSER EXHAUST TUBE 1 4 520368 MOTOR DOME 1 5 520013 CORD STRAIN RELIEF 1 6 861307 CORD W INLINE SWITCH 1 7 520329 UPPER MOTOR GASKET 1 8 520003T MOTO
7. tear neglect misuse or incorrect installation If any other replacement parts filters or attachments are used other an original Nikro parts this warranty will become void This warranty does not apply to hoses switches lights sensors or breaks in cords All motors are subject to manufacturer s warranty Contact Nikro Industries for assistance with these items Nikro disclaims responsibility for loss of production profits or any other costs that may indirectly occur due to the failure of this product

Download Pdf Manuals

image

Related Search

Related Contents

Tiré à part - La réduction du bruit en entreprise  manuale italiano mvision hd 260 wi fi  ACR 3 Hot Bonder  Manual de Usuario y Especificaciones Técnicas PARA INBEEBOX  工 事 設 計 書  Philips 110A User's Manual  manuel d`installation, de fonctionnement et d`entretien    Manual do Usuário  MODE D`EMPLOI - White and Brown  

Copyright © All rights reserved.