Home

Network Control Panel Format

image

Contents

1. Security The LogiSon Acoustic Network is secured using both physical and electronic methods The Network Control Panel is small and can easily be located within a secure space Cabling connections are made inside the enclosure A key is required to open the door and access the keypad A password is needed to change the settings There are no physical controls on the hubs or loudspeakers The network upstream from the panel is open However 28 bit AES encryption ensures that commands are unreadable whether transmitted to the panel by wired or wireless connection providing further protection from unauthorized access Downstream the network is standard RS 485 which is commonly used in building automation The panel also monitors system performance If a Relay Output Module is installed it can be connected to warning lights sirens or a third party security system to immediately alert the administrator to any issues The administrator can also elect to receive email notification via the Acoustic Network Supervisor Software For more information about the LogiSon Acoustic Network s security features see the Acoustic Network Supervisor Software and Relay Output Module sections of this catalogue or speak to your LogiSon Representative i A sound masking system s quality and durability depend on its ability construction Networked control makes changes can be made without physically cabl
2. d schedules Yes Up to I5 days user defined schedule in 0 5 or dBA steps Yes 125 per panel 375 per panel Open protected with 28 bit AES encryption Closed standard RS 485 3 pin screw terminal 6 pin 10 Base T RJ 45 3 pin screw terminal x 3 2 pin screw terminal 30 Vdc 30 Vdc Maximum 12 WV Earth ground 2 pin screw terminal x 2 1 2 AA 3 6 V 10 years 28 x 23 x 7 6 cm x 9 x 3 inches Steel with powdercoat finish Charcoal grey 2 kg 5 Ibs 20 key membrane panel 4 x 20 backlit LCD 4 keyhole mounting positions Key lock enclosure Password required to access settings 3 levels 5 years see LogiSon Product Warranty for details Meets UL FCC and CE standards RoHS compliant A LogiSon Representative will design the system and select the components Technical specifications are subject to change without notice
3. ing Such a high degree of flexibility most valuable investment employees The Network Control Panel can be wall mounted within a room or closet It provides the functionality of numerous rack mounted components reducing the costs energy and space needed for equipment The panel allows the administrator to establish timer paging and keypad zones There are no restrictions on the size of each type of zone and they can be non contiguous The administrator can also set the volume and equalizer levels for masking and paging program ramp up and timer schedules select paging channels and create user limits for each Programmable Keypad The panel uses non volatile memory so that these settings are preserved in the event of a power failure Commands can be sent to one a group or all Primary Hubs on the system Panels can be networked together so that the administrator can manage several floors an entire building or campus from one location They can also be linked to third party control systems Changes can be made in minutes following renovations moving furniture or personnel keeping the system performing at optimal levels throughout its lifecycle Paging and music are provided simply by adding one or more Audio Input Modules to the panel and connecting a source such as a telephone system or MP3 player The panel also features a priority page input that allows temporary settings to be implemented in emergencies The panels calendar based
4. nputs Zone Configuration Volume Equalization w PC Preset Contours Timer Performance Zone Number Zone Size Scheduling Volume Changes per Day Volume Increments Rate of Change Exception Schedules Delayed Start Feature Ramp Up Feature Daylight Savings Adjustment Components per Panel Max Number of Components Max Number of Loudspeakers Network Type Upstream from Panel Downstream from Panel Connections Power Input Network Output Ethernet Connection Audio Inputs Priority Page Power Input Output Consumption Ground Relay Outputs Battery Size Voltage Life Expectancy Physical Specifications Dimensions W x H x D Enclosure Color Weight Keypad Display Mounting Security Physical Electronic Warranty Certifications F SPECIFICATIONS NETWORK CONTROL PANEL Network initialization masking paging timer keypad settings zoning paging music inputs system monitoring and diagnostics 35 to 85 dBA in 0 5 dBA steps mute 3 octave 23 bands 63 to 10 000 Hz 50 preset options customization of each band 3 any combination of auxiliary telephone and microphone Zone 2 3 or none unlimited zones with Page Director Software 35 to 85 dBA min 0 5 dBA steps mute l octave 8 bands 50 preset options customization of each band Up to 9 Unrestricted Unique schedule for each day Up to 9 0 5 dBA steps 0 to 9 minutes per volume increment Up to 30 dates 3 user define
5. timer utility allows the administrator to schedule changes in the sound masking volume to match expected occupancy levels Each panel offers nine timer zones The administrator can establish a different schedule for each zone and each day of the week with up to nine volume changes per day These changes are made at a gradual user defined rate so as not to call occupants attention to them The administrator can also program unique schedules for up to 30 individual dates such as holidays The panel adjusts for daylight saving time There is also an introductory ramp up feature for retrofit installations which progressively increases the sound masking volume over a period of up to I5 days allowing occupants to acclimatize to their new acoustical conditions The administrator can program the ramp up period to begin on a defined date A unique version can be established for each timer zone For more information see the LogiSon NCP 2 User Manual PAGE 5 A LogiSon Representative will design the system and select the components Technical specifications are subject to change without notice adapt to changes as much as on its material future adjustments quick and easy because accessing the components or altering the maximizes the system s effectiveness and occupant comfort helping safeguard your NCP 2 to Control Performance Masking Performance Volume Equalization w PC Preset Contours Paging Performance Audio I