Home
Parameter Loader For Digital Controller PXH
Contents
1. Ch 3 PLT Control palette Please refer to the instruction manual concerning detail of each parameters 7 Preview parameter list 8 Print parameter list 9 Store print preview in CSV format Ch 8 SET Input output def Selection a template 010 Ch C LIN Riniaraiz Ch 9 SYS System definition System definition Ch D CLC Math Calculation Parameter mask Ch E AT Tuning Ch A ALM Alarm setting Ch G TIL Total Ch B COM Communication Ch X RCP Recipe And refer to the instruction manual and user s manual concerning operation of PXH Fig 7 1 Menu Window 7 1 Parameter setting Parameters of each channel of PXH are set and changed Example 1 Setting parameters of Ch 2 Control parameters Clicking on Ch 2 Control parameters button in the Menu Window Fig 7 1 displays Ch 2 Control parameter Setting Dialog below lt x Ch 2 PID Control parameter SettingDialog Parameter name Proportional band Integral time Derivative time Anti reset windup Upper limit value Anti reset windup Lower limit value SV upper limit SY lower limit MY upper limit MY lower limit MY change ratio limit Sampling cycle Hysteresis setting Operation output convergence value Cycle time of Control output MV1 Control operation setting Preset value for control output Alpha Beta 1 REV Reverse ope
2. 2 On the Menu Window Fig 7 1 select menu Communication C Upload U Making sure of contents on the Communication condition setting Dialog click on Execution button After parameter settings are uploaded the Menu Window appears Note A parameter setting that is under processing will be destroyed 9 How to download parameters Parameters can be downloaded from PC to PXH in the following procedure 1 Seta parameter to download by any of 3 methods below Set a parameter by New in the Work selection Window Fig 6 1 Upload a parameter setting saved in file by File open in the Work selection Window Fig 6 1 Upload a parameter from PXH via communication and change the parameter setting 2 On the Menu Window Fig 7 1 select menu Communication C Download D to set the Communication condition setting Dialog Fig 9 1 and click on Execution button Communication condition setting Dialog Download Protocol selection ETA Station No Baud rate Execution Cancel Fig 9 1 Communication condition setting Dialog After the end of downloading according to messages the Menu Window Fig 7 1 appears 10 INP TN514208 E 10 How to save parameter settings into file Select File F Save S Save As A on Menu Window Fig 7 1 parameter settings can be saved in file 11 Tuning While checking the control statuses on trend graphs of PV SV and MV P I D control para
3. 10 How to save parameter settings into fil8 oonoconnncnnncnnncnnnncconncconoconn nono nonancconnnnns 11 i A decedent bee 11 A e o 12 13 How to save print preview in CSV format ss eseeesennzznnnenzznntnzennzennzznntzazzni 13 A A 13 15 PECES A A ee A A es A 14 ii INP TN514208 E 1 Copyright of software The copyright of the software belongs to our company Itis prohibited to copy or distribute it without our consent The software is provided as communication software sample free of charge It is not intended for guaranteeing the operation of the software 2 Overview This software is an auxiliary tool for parameter setting and tuning for the digital controller PXH Setting conditions can be edited and saved by this software Upon parameter setting editing and saving on PC settings can be copied to more than one PXH Asan auxiliary tool for PXH PV SV and MV trend indication and tuning parameter P I D setting are available 3 Recommended environment Applicable PC PC AT compatible PC Applicable OS Operation was checked by Windows 2000 Japanese English version and Windows XP Japanese English version Windows 7 Home Premium Professional Japanese English version RAM 128 M bytes or more Free space of hard disk 100 M bytes or more CD ROM drive Yes Display resolution 1024 768 dots or more The operation is checked with DELL INSPIRON 3800G 750GT Laptop PC by us 4 Install
4. Fo Instruction Manual PARAMETER LOADER FOR DIGITAL CONTROLLER TYPE PXH Fuji Electric Co Ltd INP TN514208c E PREFACE Thank you for purchasing the Fuji Digital Controller Type PXH Read this instruction manual carefully to ensure correct installation and operation In addition please keep this instruction manual within easy reach of the actual person using this instrument Note Windows 2000 XP 7 are registered trademarks of Microsoft Corporation Notice OFuji Electric Co Ltd 2005 O The contents of this document may be changed in the future Issued in December 2005 without prior notice Rev 1st edition April 2011 Rev 2nd edition February 2012 O We paid the utmost care for the accuracy of the contents However we are not liable for direct and indirect damages resulting from incorrect descriptions omission of information and use of information in this document INP TN514208 E i CONTENTS PREFACE A a A des i CONTEN EStdt o o B tel li Le Copyright A e A OL 1 A O Qaabebisi bat kubi hu a g lea hieuslenasehauaateas baud 1 3 Recommended AM dais 1 4 Install and Ontario 1 Se Connection AB idas 2 ia o AA A an O 3 G2 Na deal la 3 6 2 FIle Open OR RA 4 6 3 Upload from PX Hi ii a a E T E A 5 Te Menu WAT Wisin a f a la ta dls 6 PA Parameter Seting iii in Aw Get butu Law a ebda sr Saabs 6 T2 Ments it A A AA Aa 9 8 How to upload parameters ii si 10 How to download parameters iaa 10
5. Double click on Value in the list window and you can set or change the values Double click on BIT1 to BIT16 and you can select on the pull down menu that appears whether the parameter should be displayed or masked Notes For parameter masking refer to User s Manual For some templates the masking cannot be changed Inputting unsettable value into Value automatically corrects the value INP TN514208 E 7 Example 3 Setting parameters of Ch X recipe Click on Ch X recipe in the menu screen Fig 7 1 and the following Ch X recipe list window appears lt Ch X RCP Recipe SettingDialog Recipe designation 1 Recipe designation 2 Recipe designation 3 Recipe designation 4 Recipe designation 5 Recipe designation 6 Recipe designation 7 Recipe designation 8 Recipe designation 9 Recipe designation 10 0 00 Recipe Parameter D1_ PLT1 ojolojolojojojojojo OK Cancel Setting range 0 00 To R Z3 Fig 7 4 Ch X recipe setting window Double click on Value at the top of the list window and you can set or change the values Enter the value displayed without if 201 is entered 2 01 is displayed When recipe allocation is made a recipe parameter is displayed at the bottom of the window allowing you to set data for palette selection DO PLTO to D7_ PLT7 Note Do not set p
6. and uninstall method Install Inserting the CD ROM into the drive automatically displays a top page Proceed to operation according to indications Ifthe top page does not start up automatically execute english loader setup exe at Run out of start menus Uninstall For the start menu of Windows 2000 or Windows XP or Windows 7 select Settings S Control Panel C Add Remove Applications programs for executing uninstall INP TN514208 E 1 5 Connection with PXH 1 2 Connection by RS 232C I l l l Master PC loader communication cable ZZPPXHI x TK4H4563 004 l l A PC RS232C E qi Q Gl E 0000 0800 U0 mi D Sub 9 pins Bottom of PXH Fig 5 1 Connection of PC and PXH RS 232C Prepare a loader cable option By the loader cable connect RS 232C port D sub 9 pins of PC and loader interface port of PXH Loader cable option Type ZZPPXH1 TK4H4563 Connection by RS 485 Prepare RS 232C RS 485 communication converter According to the converter s instructions carry out a connection as illustrated below Fig 5 2 Personal computer RS 485 Fig 5 2 Connection of PC and PXH RS 485 Recommended communication converter RA Systems make RC 77 isolated http www ras co jp Omron make K3SC 10 isolated http www omron co jp 2 I
7. NP TN514208 E 6 Starting window Activating PXH Loader out of start menus displays the Work selection Window Fig 6 1 Work selection includes 1 New 2 File open 3 Upload from PXH E PXH Loader Work selection Window New File E Help H ACNEE E Work selection C File open Upload from PXH Fig 6 1 Work selection Window 6 1 New Newly generate parameter setting for digital indicating controller PXH as follows 1 From Work selection Window select New and click on OK button to display the Template selection Window on Fig 6 2 PXH Loader Template selection Window New File E Help H Control type name PID control with Math SV select PID control with Math PID control SY select PID control Input select PID control with calculation Motorized valve control with Math SV select Motorized valve control with Math Motorized valve control SV select Motorized valve control Heating Cooling control with Math SY select Heating Cooling control with Math Heating Cooling control SV select Heating Cooling control gig Ble m a an eS a Ey in a a tn E a a o e m el a E Selection a template o p10 Control type name PID control with Math Fig 6 2 Template selection Window 2 Click on a desired control type name out of templates of Template selection The selected templa
8. Tuning Dialog does not change the setting value of Ch 2 SV_L1 nor Ch 3 SV1 to SV7 Check the settings of Ch 2 SV_L1 and Ch 3 SV1 to SV7 before you execute download after the end of tuning 14 INP TN514208 E Fuji Electric Co Ltd International Sales Div Sales Group Gate City Ohsaki East Tower 11 2 Osaki 1 chome Shinagawa ku Tokyo 141 0032 Japan http www fujielectric com Phone 81 3 5435 7280 7281 Fax 81 3 5435 7425 http www fujielectric com products instruments
9. arameters whose recipe parameter is not displayed for RCPO to RCP9 Note that when using the recipe function if one from RCPO to RCP9 is newly allocated the PXH default parameters are automatically inserted into all the data for palette selection Do not set PAS3 Ch 9 03 for RCPO to RCP9 Otherwise loader communication between PC and PXH is disabled 8 INP TN514208 E 7 2 Menus 1 2 3 File F New N Creates a new setting file Open O Opens an existing setting file Save S Saves a value superseding last one into file Save As A Saves a value into file Print Preview V Indicates relevant page as it appears when printed Print P Prints a value Exit X Exits PXH Loader Communication C Upload U Uploads a value of the controller Download D Downloads a value of the controller Tuning T While indicating PV SV MV with trends changes SV value and PID parameters Help H Version information A Displays version information The same operations as above menus are available by buttons on toolbar INP TN514208 E 9 8 How to upload parameters Parameters can be uploaded from PXH to PC by any of 2 ways below 1 On the Work selection Window Fig 6 1 select Upload from PXH and click on OK button Making sure of contents on the Communication condition setting Dialog click on Execution button After parameter settings are uploaded the Menu Window appears
10. d the data is forwarded in order The palette specification field displays the palette No currently selected or local selection status A desired palette can be selected on the palette specification field Double click on Value in the window and you can change the value by direct input or by selection out of pull down menus 12 Print A parameter list will be printed by Menu Window Fig 7 1 File F Print P 12 INP TN514208 E 13 How to save print preview in CSV format Click CSV save in the print preview window Fig 13 1 and you can save the contents displayed on the print display window in a CSV format file Print previewDialog CSV save Print Cancel Fig 13 1 Print preview window Note This CSV format file is different from saved on the menu window Fig 7 1 Saved files cannot be opened on the parameter loader 14 Exit Select Exit from the File F menu Or click the exit button on the upper right hand corner of the window to exit PHXLoader INP TN514208 E 13 15 Precautions 1 2 3 4 5 6 7 8 The software is provided free of charge as sample application for communication of digital controller PXH and is not intended for us to guarantee the operation of program Supply of substitute for CD ROM damaged or
11. meters can manually be adjusted SV and PID parameter settings can be changed while displaying PV process value SV set value and MV manipulating value on a currently designated Palet From this window auto tuning start stop operations are also available On the Menu Window Fig 7 1 select menu Communication C gt Tuning T to set the Communication condition setting Dialog Fig 11 1 and click on Execution button ee Communication condition setting Dialog Tuning Protocol selection ERA oo Station No Baud rate Cancel Fig 11 1 Communication condition setting Dialog INP TN514208 E 11 After operations according to messages the Tuning Dialog Fig 11 2 appears zz Tuning Dialog sv 100 PV PynB 0 00 l l l 300 270 240 210 Palette specification LOCAL y Time axis Scale Fixation Bd Parameter writing Back Setting range 0 0 To 999 9 Fig 11 2 Tuning Dialog The graph field displays trend graphs for PV SV and MV The scale of the graph field is automatically set Either Scale fixation mode or Double mode can be selected for time axis Scale fixation mode Displays the time axis 0 to 300 sec After the maximum value is reached the data is forwarded in order Double mode When displayed data reaches the left end display is continued with the time axis doubled max display 4800 sec After the maximum value is reache
12. otherwise troubled or request for up version will be with charge Latest program versions will be reported occasionally on our website This software cannot be used if a template number that cannot be selected by the parameter loader is selected on PXH For details of parameter setting refer to the User s Manual Input type PV1T PV2T can be selected out of types given in the table below according to the input unit PV1U PV2U Table 15 1 Input types Input unit PV1U PV2U setting Input type PV1T PV2T indicated as choices Cor F TC thermocouple Pt resistance bulb only non TC thermocouple Pt resistance bulb all Voltage Current If any parameter of Ch 8 Ch 9 Ch G Ch X was changed PXH must be restarted reset On this loader if downloading is executed after changing any parameter of Ch 8 Ch 9 Ch G Ch X a message appears prompting you to admit resetting and the PXH will automatically be reset While downloading after a change of scale setting PV reading may be different from a true value temporarily However it is not a failure A correct reading will be resumed after the end of downloading LoC parameter of Ch 1 has a function of inhibiting downloading by communication If LoC on PXH was set at any of 3 to 5 downloading or uploading automatically changes the LoC value of 0 to 2 Ifyou use LoC at any of 3 to 5 carry out setting manually Changing the setting SV_L1 SV1 to SV7 on the
13. ration 0 0 40 0 100 0 Setting range 0 0 To 999 9 Fig 7 2 Ch 2 Control parameter Setting Dialog Upon double clicking on Value in the Setting Dialog you can change the value by direct input or by selection out of pull down menus INP TN514208 E Example 2 Setting parameters of Ch 9 Parameter mask Clicking on Ch 9 Parameter mask button in the Menu Window Fig 7 1 displays Ch 9 Parameter mask list shown below ua Ch 9 SYS System definition Parameter maskSettingDialog Parameter name Value BIT 16 BIT 13 BIT 12 80 DS00 Parameter mask setting 00 8000 1 0N D OFF D OFF 81 D501 Parameter mask setting 01 002E D OFF TORE D OFF 82 D502 Parameter mask setting 02 0000 0 OFF D OFF D OFF 83 DSO3 Parameter mask setting 03 D OFF E D OFF 84 DS04 Parameter mask setting 04 E E 1 0N 85 DSO5 Parameter mask setting 05 E B B 1 0N 86 DSOG Parameter mask setting DB 87 D507 Parameter mask setting 07 88 DSO8 Parameter mask setting 08 89 DSO9 Parameter mask setting 09 90 DS10 Parameter mask setting 10 91 DS11 Parameter mask setting 11 92 D512 Parameter mask setting 12 93 D513 Parameter mask setting 13 94 D514 Parameter mask setting 14 95 DS15 Parameter mask setting 15 96 DS16 Parameter mask setting 16 MIINAT A lene ell aiii Ae Cancel Setting range 0000 To FFFF Hex Fig 7 3 Ch 9 Parameter mask Setting Dialog
14. te will appear in the lower of the window Clicking on OK button enters the template to use and displays Ch 8 Input output definition Setting Window Fig 6 3 INP TN514208 E 3 PXH Loader Ch 8 SET Input output def SettingWindow New Parameter name PV1 full scale PV1 base scale PV1 decimal point position PV1 input type PV1 Input Unit Value 400 0 0 0 1 3 TC K 0 0 to 1200 0 C D Degree C Degree C unit PV1 input zero point adjustment PVI input span point adjustment PV1 input rooter cut point PV1 input filter time constant PV1 Linearize type setting PV2 full scale PV2 base scale P 2 decimal point position PV2 input type 3 TC K 0 0 to 1200 0 C P V2 Input Unit D Degree C Degree C unit PV2 input zero point adjustment i PV2 input span point adjustment PV2 input rooter cut point Cancel Setting range 0 0 To 1200 0 Fig 6 3 Ch 8 Input output definition Setting Window 3 Set the input output definition as follows Upon double clicking on Value in Ch 8 Input output definition you can change the value by direct input or by selection out of pull down menus 4 Clicking on OK button displays the Menu Window Fig 7 1 6 2 File open Download existing parameter settings as follows 1 From Work selection Window select File open and click on OK Fig 6 4 Look in O Data amp e Ee 2 E sample cs
15. v My Recent Documents B esktop My Documents My Computer z jek sl Files of type CSV file cs Cancel My Network File name Fig 6 4 File selection 2 Select an existing setting file and click on Open O 3 Operating according to messages downloads parameters saved in the file into the loader and displays the Menu Window Fig 7 1 4 INP TN514208 E 6 3 Upload from PXH You can change and save a setting uploaded from PXH 1 From the Work selection Window select Upload from PXH and click on OK button 2 Select the Communication condition setting Dialog Fig 6 5 and click on Execution button Note If RS232C loader port is used set the station No to 1 Communication condition setting Dialog Upload Protocol selection EA O Station No Baud rate Execution Cancel Fig 6 5 Communication condition setting 3 Operating according to messages uploads PXH parameters and displays the Menu Window Fig 7 1 INP TN514208 E 5 7 Menu Window Menu Window Fig 7 1 has functions given below 5 Download parameters from PC to PXH 6 Jump to Tuning Dialog 1 Set and change parameters of each Ch 2 Save parameter settings 3 Read parameter settings into file 4 Upload parameters from PXH to PC PXH Loader Menu Window New File E Communication C Help H Di ma SIR alma Ch 1 OPE Operation parameter Ch 2 PID Control parameter
Download Pdf Manuals
Related Search
Related Contents
Makita FS4200 Use and Care Manual BayFedOnline Online Banking Agreement and Disclosure CG 125 Titan e Cargo Manual 2000 Watch our weight for love or money: user guide Users manual - LOCTITE Equipment JVC KV-V8 Supplementary Manual 裏K。 遍"""K"[m ブルックフィールド総合カタログ König CSGCIPH4WH mobile phone case RXT IS 260 - motos acuaticas del bajio sa de cv Copyright © All rights reserved.