Home
Network Wind User Manual
Contents
1. EXAMPLES SYSTEMS USING NETWORK WIND Only one Network WIND unit should have a wind sensor connected to it and set to transducer mode Up to three more Network WIND units can be connected on to the system network these must be set to repeater mode See SELECTING THE DISPLAY MODE For True wind functions the Network WIND must be part of a system containing Network SPEED or Network QUAD Wind Sensor 20 QUAD WIND WIND WIND Master Unit Repeater Repeater 135 F ag HB 0502 03 Network SPEED Network DEPTH Network WIND and Network TACK magnified wind angle QUAD WIND SPEED 625 125 6 155 ae UY pt p os 1 US a i la The Network units can be connected together in any order as data is shared via the system network cable link SELECTING THE DISPLAY MODE The Network WIND unit has three operating modes The correct mode must be selected for your Network system to operate correctly tu Unit mode the unit uses and displays wind data from a wind sensor connected directly into the display unit Your unit is supplied in this mode tr Repeater mode the unit operates as a wind repeater usin
2. note the set of all the sails When the conditions are steady note the apparent wind angle AWA on the analogue display e g Port 35 NOTE If you have Network TACK or Network DATA the AWA can also be read from these 2 Turn the boat until close hauled on a Starboard Tack make sure the sails are set as for the Port Tack When the conditions are steady note the AWA on this tack e g 25 HB 0502 03 3 Determine the direction of the misalignment and wind sensor offset value by subtracting the Starboard value from the Port value then dividing by two e g Port 35 Starboard 25 10 2 5 If the value is positive the misalignment is to Port if the value is negative it is to Starboard 4 Enter the wind sensor offset value into the Network WIND unit s memory by following the procedure below 5 The alignment procedure should be repeated until the displayed AWA is equal on both tacks 12 ADJUSTING THE WIND SENSOR OFFSET If the value calculated is positive the wind sensor is misaligned to Port To correct this the analogue pointer must be offset clockwise towards starboard by the value calculated Use the A key up to change the value displayed on the LCD If the value is negative the wind sensor is misaligned to Starboard To correct this the analogue pointer must be offset anti clockwise to port by the value calculated Use the w key down to change the value displayed on the LCD Press SETUP key 3 Press EN
3. will be displayed Network WIND USING THE SETUP KEY Press the SETUP key to cycle through the following options on the LCD d3 dA UF 2 i ku Network WIND HB 0502 03 dS Damping Speed this is the response time of the LCD wind speed display dA Damping Analogue this is the response time of the analogue pointer OF Offset this is the offset calibration value to correct for Wind Sensor misalignment tu Display mode this is the operating mode of the Network WIND unit LCD WIND SPEED DAMPING The wind speed damping allows the response time of the LCD wind speed display to be slowed down if the values are to jumpy in gusty conditions The damping works by averaging the wind speed over a set time period the longer the time period the smoother the displayed values however the longer it takes to see any change Network WIND allows selection of four damping values d1 d2 d4 d8 each is the approximate time in seconds The unit is supplied with a factory set value of d4 HB 0502 03 Press SETUP key once to display ds damping Speed HB 0502 03 Press ENTER key to display current damping speed The display flashes Use A or y key to cycle through the damping values Press ENTER key
4. CONTENTS CONTENTS GENERAL INTRODUCTION TO B amp G NETWORK INTRODUCTION TO NETWORK WIND EXAMPLE SYSTEMS USING NETWORK WIND SELECTING THE DISPLAY MODE THE ANALOGUE DIAL AND POINTER USING THE APP KEY USING THE TRUE KEY USING THE VOLTS KEY USING THE SETUP KEY SETTING THE DIGITAL DISPLAY DAMPING SETTING THE ANALOGUE DISPLAY DAMPING WIND SENSOR ALIGNMENT ADJUSTING THE WIND SENSOR OFFSET USING THE LIGHTS KEY HB 0502 03 o nN N D OORA N 11 12 13 INSTALLATION SITING THE UNIT MOUNTING THE UNIT SPECIFICATION ABBREVIATIONS AND DEFINITIONS THE WIND TRIANGLE CONDITIONS OF WARRANTY 14 14 14 16 17 17 GENERAL INTRODUCTION TO B amp G NETWORK The B amp G Network range of instruments is designed to be used as individual units or connected together to form an integrated navigational system A single network cable is used to carry data and power between units The latest technology and screened cables throughout the Network System ensure the ultimate protection from interference between units and other systems All Network instruments can be linked to Network PILOT Network CHART Network GPS or Network LORAN receivers or via NMEA 0183 v1 5 to other navigational equipment INSTRUMENTS NAVIGATIONAL AIDS Network SPEED Network GPS Network DEPTH Network LORAN Network QUAD Network NAV Network WIND Network CHART Network TACK Network DATA AUTOPILOTS COMMUNICATIONS Network PILOT Network VHF HB 0502 03 INTRODUCTION T
5. O NETWORK WIND The Network WIND unit measures and displays wind information on an analogue 360 Apparent Wind Angle meter and a back lit Liquid Crystal Display LCD The five keys allow selection of the information displayed on the LCD and setting of the units mode Wind Sensor offset calibration and display damping It can operate as the main Network WIND unit either alone or as part of an Intregrated Network Instrument System taking inputs directly from a Wind Sensor which plugs into the socket at the rear of the display or as a repeater of wind information received via the two Network cable tails For true wind functions Network WIND must be connected to a system that contains a Network SPEED or Network QUAD unit as boat speed is required The unit is able to transmit NMEA 0183 v1 5 data via the network cables to other Network units and connect to an NMEA device e g a position fixer with a special NMEA output cable The unit has no internal alarm or alarm functions IMPORTANT NOTE Your Network WIND unit must be setup and calibrated correctly before it is used as part of a navigational system HB 0502 03 NETWORK WIND DISPLAY UNIT N B amp G Network WIND APP TRUE VOLTS SETUP LIGHTS a v S Y PRET
6. TER key to times to display OF display current value OFfset value The display flashes Factory set to zero HB 0502 03 Use A or w key to adjust the value A clockwise w anti clockwise Press ENTER key to memorise the new value After 30 secs the display will revert to previously selected display 13 USING THE LIGHTS KEY The Network WIND Display unit has 3 levels of illumination and off controlled by the LIGHTS key The level selected is for the whole Network system LO L3 L2 L1 OFF High Medium Low The LIGHTS key also changes the illumination level of the key legends it always remains illuminated so even in complete darkness the key can be located HB 0502 03 14 INSTALLATION The display heads are supplied with a clip in mounting bracket which allows for easy installation access from behind is not necessary to secure the unit in place However to prevent theft and permanently fix the unit in position locking studs and thumb nuts are supplied SITING THE UNIT All Network Instruments are designed for mounting on or below deck A mounting position should be selected where they are e Easy to read by the helmsman e On a smooth and flat surface e At least 100mm 4 from a compass e Accessible from behind for fitting locking studs if required HB 0502 03 MOUNTING THE UNIT Use the cutting template supplied to mark the centres of the holes for the self tapping screw the fixing s
7. g data from the system network td Demo mode the unit runs an internal demonstration program Press SETUP key 4 times Press ENTER key if the Use A or v key to Press ENTER key to to display current mode mode needs to be change the mode memorise the new mode After changed The display 30 secs the display will revert flashes to previously selected display HB 0502 03 THE ANALOGUE DIAL AND POINTER USING THE APP KEY The analogue pointer always indicates Apparent Wind Angle Press the APP key to display Apparent Wind Speed on the on the 360 dial Each division marker is at 30 intervals The LCD The LCD APP legend will be displayed LCD is offset to the left so when running with the wind astern the wind angle can still be read clearly Network WIND Network WIND HB 0502 03 USING THE TRUE KEY Press the TRUE key to display True Wind Speed on the LCD The LCD TRUE legend will be displayed If boat speed data is not available the LCD digits will be blank and the TRUE legend will be displayed 7 Network WIND S N EY HB 0502 03 A USING THE VOLTS KEY Press the VOLTS key to display Battery Volts on the LCD The LCD V legend
8. head cockpit mounting Vented barrel to prevent condensation HB 0502 03 ELECTRICAL Power Supply 12V DC nominal 10 to 16V Operating Current 40mA typical 100mA illuminated Protection Connect via external 5A fuse or circuit breaker CABLES AND CONNECTIONS Connection to adjacent units is via cable tails fitted with either a plug or a socket Extension cables are available from your dealer The cable tails carry power and NMEA data between units ALARM There is no internal audible alarm NMEA OUTPUT SENTENCES IIHDM Heading SIIVHW Speed and Heading IIDBT Depth IIVWR Apparent wind angle and speed SIIMTW Sea temperature 17 ABBREVIATIONS AND DEFINITIONS THE WIND TRIANGLE AWA Apparent Wind Angle The angle between the boat s bow and the wind blowing across the E deck at mast height k Dire i E a AWS Apparent Wind Speed The wind speed across the deck at mast height TWA True Wind Angle The wind angle between the boat s heading and the true wind at mast height This is calculated from AWA AWS and pus Si boat speed This is the wind relative to the a water not the land Heading TWS True Wind Speed The wind speed over the water independent of the boat s motion through it Calculated from AWA AWS and boat speed VMG Velocity Made Good A measure of performance upwind or downwind calculated from TWA and boat speed HB 0502 03 18
9. to memorise the new value After 30 secs the display will revert to previously selected display 10 ANALOGUE POINTER DAMPING The analogue pointer damping allows the response time of the analogue display to be slowed down if the values are to jumpy in gusty conditions The damping works by averaging the wind angle over a set time period the longer the time period the smoother the displayed values however the longer it takes to see any change Network WIND allows selection of four damping values d1 d2 d4 d8 each is the approximate time in seconds The unit is supplied with a factory set value of d1 Press SETUP key Press ENTER key to Use A or Y key to twice to display dA display current cycle through the damping Analogue damping speed The damping values display flashes HB 0502 03 Press ENTER key to memorise the new value After 30 secs the display will revert to previously selected display 11 WIND SENSOR MISALIGNMENT CORRECTION For accurate wind angle readings the wind sensor should be pointing forward and aligned with the centreline of the boat However this is not always possible so Network WIND allows a wind sensor offset value to be entered to compensate for the misalignment electronically Firstly the amount of misalignment must be found The following procedure will enable you during the course of a sea trial to establish the value 1 Sail close hauled on a Port Tack
10. tud holes and the mounting bracket e The template allows 4mm 5 32 between adjacent units for the suncover increase this distance if required to maximum of 60mm 2 3 8 between units or 180mm 3 1 8 between centres For greater distances between units extension cables are available e Use a 70mm 2 3 4 diameter hole cutter for the mounting bracket hole Use a 2 9mm for the self tapping screw holes e Use a 5mm 3 32 drill for the locking stud holes e Secure the mounting bracket to the bulkhead with the self tapping screws supplied Fit the rubber sealing gasket around the mounting bracket e Screw the locking studs into the back of the display if required e Carefully pass the cable tails through the mounting bracket hole connect the cables to the main units Clip the display head into the mounting bracket e Secure the instrument with the thumb nuts supplied head 15 INSTALLATION HB 0502 03 16 SPECIFICATION PHYSICAL PARAMETERS Construction High impact ABS plastic Window Acrylic Display Analogue dial and pointer Back lit Liquid Crystal Display Digits 12mm 0 47 Dimensions 110 x 110 x 25 4mm 4x4 x 1 Requires 65mm 2 6 depth behind bulkhead for display barrel Weight 0 3 kg 0 66lbs ENVIRONMENTAL Operating Temp 10 to 55 C 93 RH 14 to 131 F 93 RH Storage Temp 25 to 70 C 95 RH 13 to 158 F 93 RH Humidity Up to 95 RH Sealing Fully sealed front suitable for bulk