Home

TEMPERATURE RECORDER (0 ÷ 300°C)

image

Contents

1. TEMPERATURE RECORDER 0 300 C HIR Code 65 INSTALLATION AND USE MANUAL Rev 1 dated 16 06 2014 1 LogikaControl INDEX Technical features Accessories supplied Accessories on request Caution Electrical drawing Programming Messages and alarm codes Enabling the device to record Download data Cleaning the device Disposal Warranty Edition list CE Declaration Rev 1 dated 16 06 2014 page 3 page 3 page 3 page 4 page 5 page 6 page 11 page 12 page 13 page 14 page 14 page 14 page 14 page 15 LogikaControl TECHNICAL FEATURES e Power supply 230 V 15 50 60Hz e Consumption 25 Protection degree IP64 for the frontal panel IP20 for the other parts e Working temperature 5 50 C with 90 RH non condensing Storage temperature 20 60 C Box material black grey ABS auto extinguishing VO Connections via terminal block to wires Nr 6 key buttons Nr 2 inputs for PT 1000 temperature probes working range 0 300 C precision oie ps Nr 1 USB Host output for downloading flash memory driver USB Visualization through back light graph LCD 128 x 64 dots Nr 1 time keeper precision 0 1 buffer battery non rechargeable electrical life over 10 years Capacity flash memory loop buffer last data overwrite on the first one 170 000 records by 1 sensor connected 85 000 records by 2 sensors connected
2. Select the function needed and confirm byJ the LCD visualizes the message Are you sure and NO visualized as reverse YES If YES is confirmed by the blinking message Resetting is visualized to indicate reset in progress once reset is finished the LCD shift back to the previous visualization If NO is confirmed by J the LCD shift back to the previous visualization 3 Change password Confirming by the password setting is shown again enter the new password according the same procedure and the new password will be typed once requested into the Reset function NOTE it s advisable to change the default password number in case the device is used by personnel not authorized to this function PASSWORD MISSED In case of password missed forgotten take power off supply power again keeping the buttons f and J simultaneously pushed for 5 seconds while the LCD visualizes the blinking message D P L loading default password To enter into the Reset menu now you have to enter the default password 0000 Rev 1 dated 16 06 2014 9 LogikaControl Info 1 5 Into this function you can read firmware version company title and ID recorder setting data buffer memory status Communication 1 6 By the buttons f and or select the desired function and confirm byg l Communication allows to visualize change the following parameters P20 Mode MODBUS default or
3. Nr 1 input for detection door micro switch open free contact Nr i relay 1 A 250V with free contacts for remote alarm Nr 1 input for buffer battery to grant continuous recording over 12 hours in case of power off see technical features on electrical drawing page 5 Nr 1 serial port RS232 for connection to Logika GSM module or Modbus Attention when the recorder is powered by buffer battery download data is not allowed Settable parameters year month day hour minutes language Italian English French German Spanish Greek Portuguese User company title ID recorder Analogue inputs Records interval 1 240 minutes Positive and negative alarm for each analogue channel Delay alarm 1 60 minutes Weight 1 200 g Accessories supplied Nr 1 USB Flash Drive including instruction manual and Windows application for data processing as graphic and or statistics Accessories on request Temperature probes PT1000 code BSTWO015 Buffer battery code OKLC946A GSM module code OJLC5L5B Rev 1 dated 16 06 2014 3 LogikaControl CAUTIONS Logika Control informs every modification or tampering on HTR and or operations in disagreement with the manual void both the warranty and the original CE declaration Remember the technical data are related to HTR SEE TECHNICAL FEATURES PAGE 3 the drawing pictures and any other document are property of Logika Control s r l which reserves all rights
4. Damages resulting from tampering impact or improper installation Behaviour inconsistent with Manufacturer s prescriptions and instructions Damages caused by repairs made by unauthorized personnel In all above cases repair costs shall be charged fully to the Customer The Manufacturer cannot be held liable for any direct or indirect damages to animals people or things as a result of failure to observe all the instructions information in the user manual especially instructions concerning installation use and maintenance of the device For all matters not expressly indicated the warranty is subject to the regulations contained in the Italian Civil Code art 1512 The competent court for any controversies is acknowledged to be the Foro Monza Logika s r l cannot be held liable for possible errors or inaccuracies written in this manual as a result of printing or transcription errors Logika s r l reserves the right to modify its products without prior notice as it deems necessary without altering their main characteristics Each new release of Logika Control user manual replaces the previous ones EDITION LIST Rev 0 1 edition 02 02 2011 Rev 1 Modified electrical drawing due to mistake in the previous one 16 06 2014 Rev 1 dated 16 06 2014 14
5. before the installation the user is obliged to check the electrical plant is in accordance to the nominal power supply of HTR SEE TECHNICAL FEATURES PAGE 3 The product is developed in environment with pollution degree 2 The product can not be used as safety device HTR is not intended for use in potentially explosive atmospheres Only qualified LOGIKA personnel may carry out technical support on this product Overall dimensions of the device mm Integrated version Fixing hole The electrical connection must be carried out by authorized personnel according the electrical drawing below and related legend and in power off status so pay attention the isolator switch that HTR depends on the power supply is in OFF position ATTENTION the connection to the electrical grid must be carried out as last operation Rev 1 dated 16 06 2014 4 LogikaControl ELECTRICAL DRAWING LEGEND Terminal M1 poles 1 2 power supply 230V Terminal M2 serial port RS232 pole 1 GND pole 2 TX pole 3 RX pole 4 out Vdc 4 7 V Terminal M3 pole 1 negative pole 2 positive buffer battery Terminal M4 poles 1 2 temperature probe zone 1 poles 3 4 temperature probe zone 2 Terminal M5 poles 1 2 door micro switch Terminal M6 Alarm relay poles 1 2 max current 1A 250Vac with free contacts pay attention alarm status comes when relay s coil de excited it means on poles 1 and 2 C NC For th
6. 45 m ALO5 Probe failure alarm activation time with related code and sliding description for limited space 13 08 PO5 150 C modification time of a parameter with new value 13 18 69 17 52 12 11 10 change of date and time Rev 1 dated 16 06 2014 8 LogikaControl Reset 1 4 This function allows to enable the following reset protected by_ password max 4 numbers default 0000 Confirm the function by and the LCD visualizes Enter Password by the buttons and or J enter the first number and confirm by J to shift to the next one the number just entered is changed into the symbol after the fourth numer and the password is right the LCD visualizes the following messages Setting Records Change Password In case of wrong typing by pushing Tf J simultaneously it s possible to shift back to the previous number if the password is wrong the LCD visualizes for few seconds the blinking message Password Wrong and shift back the visualize RESET 1 Setting the recorder returns to factory setting before the installation this function is allowed if there is not any data into the memory only in case of data into the memory the LCD visualizes the message DONWLOAD MEMORY 2 Records erase the records memory this function is allowed if there is not any data into the memory and no recording in progress only in case of data into the memory the LCD visualizes the message DONWLOAD MEMORY
7. GSM a When MODBUS is selected the parameter P21 is visualized only b If GSM is selected the display visualizes GSM 00000 where you have to enter the SIM number placed into the module just as reminder the display visualizes the parameters P22 P26 P21 1 32 default 1 Modbus address of each unit in the net P22 GSM phone number 000000000 P23 PIN code 0000 if pin code is not enabled leave 0000 see PIN alarm P24 SMS Dest 1 000000000 enter the phone number of the 1 cell phone P25 SMS Dest 2 000000000 enter the phone number of the 254 cell phone P26 SMS Dest 3 000000000 enter the phone number of the 3 cell phone NOTE GSM selected a When an alarm is detected by the recorder the GSM will send an SMS to the cell phones set with the following information Company title Recorder ID probes selected Alarm codes detected In case of power off and recorder powered by buffer battery the GSM will send the information above further to the message ON BATTERY once the main power is restored the GSM will send another SMS with the message POWER OK b By sending from an SMS with word STATUS it doesn t matter capital letter or note from any cell phone to the GSM module the GSM will reply automatically with the message NO ALARMS in case of no alarm detected or related codes in case of alarm detection Symbols reported on the right low corner of the display of HTR con
8. e connection to GSM module code OKLC5L5B use a shielded 3 poles cable AWG22 with max length no more than 2 m see connection drawing below Scheda CRR Connettore M2 4 7V sT 6 q 4 7V x Ho Se BB RX a RX Connettore M1 Scheda Modulo GSM OKLC5L5B ATTENTION In case of power off during records in progress the following events could happen 1 If the buffer battery is not connected the recording stop the alarm relay start to signal the alert event 2 If the buffer battery is connected it starts working granting the recording for around 12 hours time the back light switches off and the download data is not allowed Rev 1 dated 16 06 2014 5 LogikaControl PROGRAMMING program HTR and enable the recording follow the instruction reported below Once HTR is powered the LCD visualizes the following message for few seconds HTR by Logika Control V 00x firmware release and then visualize the picture nr 1 below NOTE after 3 minutes from the last pushing of a button the back light of the LCD switches off to switch on again once any button is pushed again energy saving Picture nr 1 visualization with one temperature probe selected On upper corners of the LCD are visualized the time left and the date right 05 10 2010 OFF Menu Pushing J Menu you enter into the programming device and visualization of the different functi
9. ed check if the USB key is failure or full Change time DLS Standard time informs about change time Alarm codes 00 flash memory error the LCD visualizes the message OFF replace the recorder AL O1 timekeeper failure after download data the LCD visualizes the OFF replace the recorder The printing data reports the message timekeeper failure AL O2 Power OFF missing power the printing data reports the time when power off comes this alarm is detected if the buffer battery is connected and the recordings are in progress only AL O3 Power ON restore power the time when the power is restored is recorded into the memory the alarm is detected with recordings in progress only AL 04 Door open door input is open over the time set in the parameter P10 close the door the alarm is detected with recordings in progress only AL O5 Temperature probe T1 failure the printing data reports the related alarm code replace the probe 06 temperature probe T2 failure the printing data reports the related alarm code replace the probe AL O7 high temperature alarm temperature detected by is over set 05 alarm detected once timer PO9 is over and recordings in progress only AL O8 low temperature alarm temperature detected by T1 is below set P06 alarm detected once timer PO9 is over and recordings in progress only AL O9 high temperature alarm temperature detected by T2 is over set P07 alarm de
10. nected to a GSM module T Antenna the GSM is connected ll Net coverage if this symbol is blinking it means there is not net coverage so the GSM module has to be placed in another position Max distance between HTR and GSM module no longer than 3 meters FII It blinks in case you enter a wrong pin code in this case quit the programming switch off and then switch on the HTR enter the pin code again to avoid after 3rd wrong attempt the SIM card lock and you have to enter the puk code to unlock i It blinks when the SIM card is not in FRR General error replace the GSM module Modbus selected units connected as serial net and software application installed on the PC in this case it is possible both monitor the temperature and download data recorded by the several HTR connected in the net Rev 1 dated 16 06 2014 10 LogikaControl Visualization with two temperature probes MESSAGES AND ALARM CODES Messages Download data due to a memory full loop memory once it s full overwriting starts last data erase the first one b change a parameter while data to download into the memory disable recording and download the data before to modify any data Push button download data when the USB key is IN Download data with progress bar and related download data in progress Drive USB key Completed blinking download data over Drive USB key Error blinking download data not succe
11. ommand set and protocol 0x50 Bulk Only Transport formatted FAT16 o FAT32 with sector dimensions 512 byte windows default Different File system example NTFS or different sector dimensions example 1024byte are not supported CLEANING THE DEVICE The plastic box cab be cleaned by no aggressive detergent while the front panel by a cloth moistened with water and soap DISPOSAL The HTR is composed by plastic cables printed circuit and electrical components for this reason it has not to be disposal in the environment For a right disposal ask for specialized companies WARRANTY HTR temperature recorders are covered by a 24 months warranty against all manufacturing defects as from the production date printed on the label of the device identifying the year by the first 4 characters the week by the second 2 characters and the progressive serial number with the last 5 characters Rev 1 dated 16 06 2014 13 LogikaControl In case you need to use the service assistance during the warranty period the product must be send back to the distributor you bought it paying attention it must be intact and packed into its original package Customers are entitled to have defective products repaired spare parts and labour included Transport expenses and risk shall be met entirely by the Customer Repairs carried out under warranty do not prolong or renew the warranty expiration date The Warranty does not cover the following cases
12. ons flow up down the functions through 1 and Jl once the function is selected confirm by J After 3 minutes inactivity on the key buttons the visualization shift back to the main menu automatically Programming functions 1 Visualizations 2 Setting 3 Records 4 Reset 5 Info 6 Communication Rev 1 dated 16 06 2014 6 Pr LogikaControl Visualizations 1 1 Visualizations ltalian C OF EI 10 23 Thu 12 07 2007 DST Standard time YES By the buttoons 1 and or J select the function to set and it will be visualized as reverse from positive to negative language Italian English French German Spanish Greek Portuguese default English temperature scale C F default C display contrast according ambient light where the recorder is installed time and date setting with possibility to switch between DLS and Standard time where YES the recorder updates the time automatically NO the updating DLS Standard time is not operated Once the function is selected by pushing the setting is enabled and the function starts blinking by the buttons 1 and or set the new data and confirm by J the function stops blinking after last setting the visualization shift back to the previous one D Setting 1 2 By the buttons Tfand or select the function to set and confirm by J the square on the right starts blinking till by 1 and or J set the new value and confirm by J push ESC to shif
13. s possible to change the default value 300 C alarm disabled setting range 0 300 C PO6 Low temperature alarm related to the probe T1 in the square in the right is possible to change the default value 0 C alarm disabled setting range 0 300 C Rev 1 dated 16 06 2014 7 LogikaControl 7 High temperature alarm related to the probe T2 in the square on the right is possible to change the default value 300 C alarm disabled setting range 0 300 C POS Low temperature alarm related to the probe T2 in the square in the right is possible to change the default value 0 C alarm disabled setting range 0 300 C NOTE when temperature rise up or goes down the setting value the timer related to parameter PO9 starts once it s over if the temperature is still over up or down the setting value the LCD visualizes the related alarm code and the alarm relay de excites POS Alarm positive negative delay in the square on the right is possible to change the default value 30 minutes setting range 1 60 minutes P10 Door open alarm delay once this time is over if the door input is still open the LCD visualizes the code alarm and the alarm relay de excites in the square on the right is possible to change the default value O minutes alarm disabled setting range O 60 minutes NOTE 1 If you need to set one or more parameter PO5 P08 they have to be enabled once the refrigerator reaches the
14. t back to the main visualization PO1 Company title in the square on the right name reported on the printing data max 15 alphanumerical characters setting comes through f and or for each letter or number keep on pushing for fast forward and confirm by J the square moves on the right at the end of setting pushing twice two white spaces enter to confirm the name and quit in case of wrong typing pushing ESC the cursor shift back to the previous character keep on pushing J for about 2 seconds to cancel all the characters on the right and confirm the last one entered 02 ID Recorder for example cell name in the square in the right set the code name will identify the recorder name reported in the printing data max 15 alphanumerical characters and the setting procedure is the same for company title as well 03 Record interval time to pass between a recording and next one in the square on the right is possible to change the default value 30 minutes setting range 1 240 minutes NOTE the parameters P1 P2 P3 is required to be configured otherwise the records can t be downloaded to the PC through the software application 04 Enabling the probes connected in the square the right is possible to change the default value T means temperature probe 1 probe Ti default 2 T1 T2 visualization of the parameter PO7 and P08 POS High temperature alarm related to the probe in the square on the right i
15. tected once timer 9 is over and recordings in progress only AL 10 low temperature alarm temperature detected by T2 is below set P08 alarm detected once timer 9 is over and recordings in progress only AL 11 Overwriting records due to memory full download data Rev 1 dated 16 06 2014 11 LogikaControl If one or more alarms are detected the LCD visualizes the delta icon generic alarm symbol and related code the relay contact closes between the poles 1 2 of the terminal M3 Pushing 1 and or enter the alarm active list and you can flow up and down by the same arrow buttons it s possible to reset the alarm by J if the cause has been solved only Every alarm reports date and detection time 11 09 42 05 10 2010 4 0 ALO3 All the alarms are reported in the printing data with related detection date and date the related casue has been solved In case of power off and buffer battery connected the battery icon starts blinking in this status the download data is not allowed automatically disabled ENABLING THE DEVICE TO RECORD Once the programming is complete the device is ready to record according the following way Temperature probe T1 connected and selected By the button REC you can enable and disable the recordings when the recording is enabled the LCD visualizes the temperature detected and the symbol for record in progress when the recording is disabled the LCD
16. visualizes the OFF Records in progress Probes T1 T2 connected and selected By the button REC the LCD visualizes REC ON OFF M rM 01 09 2010 C By and or lselect the zone you need to enable or disable square blinking the recording and push J to activate election flag is shown or deactivate it selection flag disappear Push REC to confirm and the visualizes the temperature of the zone enabled for the recording with the related rec unig symbol or message OFF in case it s disabled Rev 1 dated 16 06 2014 12 LogikaControl DOWNLOAD DATA Operation allows by the main menu onl Insert USB key in the proper housing after you remove the cover cap D The LCD visualizes the message Drive USB key Push button download data Push the button near USB key and LCD visualizes the message Download Drive USB key Complete Under the message Drive USB key is a bar indicating the download progress at the end of download the bar change into the message Complete blinking Take the USB key out and remember to cover the housing with the proper cap to keep IP protection of the device The file into the USB key is converted into a non changeable format by the PC to avoid any tampering original data are the ones into the flash memory of the recorder USB FLASH DRIVE SUPPORTED Flash drive USB supported class 0x08 Mass Storage Class subclass 0x06 SCSI transparent c
17. working temperature only 2 If you enter into the setting try to change any parameter but the memory keep data not downloaded yet the LCD visualizes the message DONWLOAD MEMORY in this case stop the recording and change the setting value once you ve downloaded the memory only Records 1 3 Visualization and or print of the records stored into the memory for a defined period From day month year To day month year By the buttons 1 and or 5 the start end date every date must be confirmed by J after last data the LCD visualizes the followings 1 Visualization see example of visualization 2 Download it s shown when the USB key is IN only By the buttons ff and or select the function needed and confirm by If Visualization has been selected the LCD visualizes all the records eventual alarms detected and the changes of any parameters if any with related date flow up down by TT and or 1 by J shift back to the main visualization If Download has been selected push the related data for starting download data Example of Visualizations The first page reports the date of the event on the upper left corner and the data of the event in the next one 1 example of visualization of the records with three analogue channels enabled 12 11 10 T1 C T2 C 12 15 14 5 one 2 visualization of the events 12 00 START REC T1 T2 start recording 12 00 STOP REC 2 stop recording 12