Home
8 - Medivators
Contents
1. a ae W W SITE REQUIREMENTS AND INSTALLATION DSD EDGE a Following these instructions accurately and completely will provide consistent and correct installation procedure for the DSD EDGE APPLICABLE DOCUMENTS e DSD EDGE User Manual INSTALLATION KIT The DSD EDGE reprocessor is provided with an installation kit to adapt the unit to building supplies The e DSD EDGE Service Manual following items included in the kit are used during installation ITEM DESCRIPTION 4 3 8 Water Regulator 2 PressureGauge 3 3 8 pug oo 4 Presfitration system 5 tmicronfiter 6 045 micron fiter e Tinh drainhose o Tineh dain elbow 10 Pre fiter installation hose kt Below is an overview of the water supply and pre filtration system connections For detailed instructions EJ WATER SUPPLY POTABLE AND PRE FILTERS OVERVIEW e please refer to the instructions included in the pre filtration system Dimensions of the water pre filtration system are shown in Figure 1 An incoming water shut off valve must be installed upstream of the pre filter system The valve must be easily accessible to the user to shut off the water supply when not in use Ensure the incoming water pressure provides a flow rate of 3 2 gal min 12 liters min at a minimum pressure of 40 PSI 2 75 BAR but not more than 90 PSI 6 2 BAR A customer supplied water temperature mixing valve must be installed before the pre filter system The mixing valve m
2. hook up fitting may blow the slow blow fuse MEDIVATORS FINAL TESTS To be sure that the system is ready to operate perform a trial run with water as outlined below Use the Restrictor Hook up to simulate an endoscope Three full cycles must be completed without an alarm e Install high level disinfectant Part A and Part B containers as described in User manual e Press the START button e Check the flow through the tubing during the disinfect air and rinse cycle e Check if incoming water pressure regulator provides a flow rate of 3 2GPM 12 liters min at a pressure of 35 40 PSI 2 4 2 75 BAR Adjust the External Water Regulator during the Flush Cycle e Adjust the internal regulators to 18 20 PSI 1 25 1 38 BAR during the Flush Cycle e Verify the unit is level Watch the rear basin overflow during the HLD cycle Disinfectant should not flow over this drain If fluid escapes over the drain during the HLD cycle the unit is not level Adjust the screw pads and re test e Verify the cycle completes with no errors e Verify there is no fluid on the floating lid after a cycle e Verify there are no leaks in the reprocessor e Perform a water line disinfection procedure using the restrictors as described in the user manual The Installation Verification form is used to document that the reprocessor has been properly installed INSTALLATION VERIFICATION 9 tested and is ready for operation Medivators Website Resource Ce
3. n gauge 1 is 40 PSI 2 75 BAR a filter change is required UNIT SET UP Move the reprocessor to the installation location before removing the protective packaging material If this is not possible use a hand truck or moving dolly and ensure the reprocessor is not damaged The reprocessor must be installed on a level surface or be adjusted to level Adjust the leveling pads after unpacking the reprocessor SYSTEM DRAIN 6 Connect the 1 drain elbow to the rear drain of the DSD EDGE The elbow threads require Teflon tape Connect the drain tube provided with the reprocessor 36 inches of 1 inch diameter clear tubing to the drain elbow The drain tube must have 3 inches of drop 7 5cm or greater over the 36 91cm length Consult your maintenance department for multiple reprocessor installation CAUTION The reprocessor drain relies on gravity flow There must be no low spots or loops o in the drain line Fluid trapped in the drain line will interfere with free drainage and reprocessor function K FIGURE 3 SAMPLE OF A DRAIN INSTALLATION ELECTRICAL e Plug cord into outlet The outlet should be placed within operators reach for easy unplugging fo CAUTION The reprocessor does not have an ON OFF switch Be sure the reprocessor is positioned so that the power cord or main circuit breaker is accessible at all times Cay WARNING The reprocessor must be protectively grounded Cay CAUTION Operating the reprocessor without a
4. nter Go to www minntech com medivators Select Resource Center and User Library for detailed user guides and hook up matrices report forms and logs and product bulletins Medivators Customer and Technical Support 1 800 444 4729 MINNTECH CORPORATION All rights reserved 50097 091 A
5. tighten only Over tightening will result in failure of the pre filter components which can lead to flooding or water leaks Plumbing fittings should be hand tightened followed by one complete turn with the appropriate wrench Cay NOTE If the water supply line is brought in from the opposite side of the system inlet run it behind the machine close to the floor so that the disinfector can be flush against the wall with the water line running through the base recess e Install the regulator supplied in DSD EDGE accessory kit between the filter assembly and the DSD EDGE REGULATOR SET UP 4 e The external regulator water pressure is set between 35 40 PSI 2 40 2 75 BAR This adjustment is performed during the flushing cycle after the unit is ready for cycle verification L WARNING DO NOT over tighten water filter housings hand tighten only Over tightening will result in failure of the pre filter components which can lead to flooding or water leaks Plumbing fittings should be hand tightened followed by one complete turn with the appropriate wrench The accumulation of particulates in a filter can cause the water pressure to drop below the minimum required level This can occur every two to three months depending on water quality A pressure differential of 5 PSI 0 35 BAR or greater between gauges on each side of a filter indicates a need for replacement For example if the pressure on gauge 2 is 35 PSI 2 41 BAR when the pressure o
6. ust be able to maintain a water temperature of 95 F 4 F 35 C 2 C Install the incoming water pre filter supplied with the reprocessor The user must have an easy access to the filters There should be enough room below the filter assembly to be able to change the filters Install the external water regulator between the outlet of the pre filter assembly and the DSD EDGE Attach one end of the stainless steel water hose to the regulator Attach other end to the water inlet of the DSD EDGE The installation kit ships with hardware that should fit most installations If not the hardware may be sourced locally Mount the filter assembly on the wall where the filters can be easily changed and the gauge checked L NOTE Use 1 2 inch piping for all water line plumbing a NOTE This unit is piped and assembled as shown with the outlet on the right side and gauge 1 incoming water pressure on the left figure 1 MEDIVATORS Gauge 1 Gauge 2 Or Coe important Turn off water supply to roprocessor at the end of the day Gauge 3 lt 9 75 inches f Important Turn off water supply to reprocessor at the end of the day Water Outlet To DSD Edge Water Inlet From main water supply 16 inches Contains ie Contains 0 45 micron filter Depts unit is approximately 6 inches FIGURE 1 FILTRATION SYSTEM DIMENSIONS FIGURE 2 FILTRATION SYSTEM Cay WARNING DO NOT over tighten filter housings hand