Home

Motion Studio User Manual

image

Contents

1. Camera Model Minimum Firmware version FW MW Y3 Classic 109 89 Y3 S1 S2 Any version Y4 125 102 Y5 125 102 Y6 142 120 Y7 Y8 Any version N3 NR3 S1 S2 150 112 N3 NR3 S3 Any version N4 NR4 150 112 N5 NR5 153 116 NR7 NR8 Any version NX NX Tra NX Air Any version O Os Any version NOTE X series HG series and M series are NOT supported by Motion Inspector Users Manual Motion Inspector 2 3 How to disable the User Account Control on Windows UAC To disable the User Account Control on Windows follow the instructions below Gd 1 Open the Control panel and select the User Accounts option 2 Enter the page that manages you account 3 Click the Change User Account Control option 4 Move the slider to the bottom like in the picture below to the never notify position 5 Click OK and restart Windows Tell me more about User Account Control settings Always notify Never notify me when e Programs try to install software or make changes to my computer e Imake changes to Windows settings O Not recommended Choose this only if you need to use programs that are not certified for Windows 7 because they do not support User Account Control Never notify 8 Users Manual Motion Inspector 2 4 How to configure the Windows Firewall All the cameras that support gigabit Ethernet communication may have issues if the ag W
2. System Menu Camera Enumeration Users Manual 13 Motion Inspector 3 1 System Menu Click the button on the bottom left area of the main window to open the system menu Options open the general options window see below Motion Viewer start the Motion Viewer About open the About Box and display information about the version Advanced opens the advanced dialog box when a camera is operating Exit exit the program 3 1 1 Camera enumeration button 14 Click the camera button to search for cameras and refresh the camera list Users Manual Motion Inspector 3 1 2 General Options 8 General Options N Y A eee a H Ee Download Folder ACQUISITION FOLDER ENABLE TRACE AFTER ACQUISITION NETWORK ADAPTER RK PERFORMANCE ETHERNET DATAGRAM SIZE EXPOSURE FORMAT lt lt lt lt lt lt lt lt Download folder click Browse to change the folder where the images are downloaded Acquisition Folder Name each time a sequence is downloaded a new folder is created The name may be a combination of date and time or it may be edited by the user Enable Trace enable and disable the trace The trace file mi_trace txt is stored in the download directory After acquisition when the trigger is received and the images acquired MI can automatically download and erase the memory or open the payback page Network Adapter select the network adapter connected
3. ES Windows Firewall is off a Pg Windows Firewall with Advanced Security provides network secu dy Import Policy Diagnose Repair View Private Profile is Active IG Refresh ES Windows Firewall is off Properties Public Profile is Active Help ES Windows Firewall is off E Windows Firewall Properties Gettina Started 4 m Click the Windows Firewall Properties button and open the Properties dialog box Select the Domain Profile tab and set the Firewall State to off then select the Private Profile and set the Firewall State to off and then select the Public Profile and set the Firewall State to off ap rote vere gt Domain Profile Private Profile Public Profile IPsec Settings Specify behavior for when a computer is connected to its corporate domain State Inbound connections Block defaut Outbound connections Allow default y Protected network connections Customize Settings Specify settings that control Windows S aie haa Customize Logging Specify logging settings for troubleshooting 12 Users Manual Motion Inspector 3 Motion Inspector Motion Inspector allows the user to control one or two cameras acquire and save play back image records Once the program is started the window below appears a _ Motion Inspector powered by IDT FG
4. internal is allowed Users Manual 27 Motion Inspector 3 11 Trigger In Select one of the options in the list Motion Average change 3 11 1 Motion trigger e Click the Motion Trigger button e Select the motion option Average or motion detection and increase or decrease the level e Move and or resize the rectangular grid and test the condition by checking if the background color changes from red to green e Click Reset to reset the grid to the window size and or Center to center it e Click Apply to start the acquisition If the condition turns into true the camera triggers 3 12 Image The configuration is split into two areas pixel depth and HDMI if available on the left and image parameters on the right 28 Users Manual Motion Inspector 3 12 1 Pixel depth Flip and HDMI Pixel depth 8 9 or 10 bit for monochrome cameras 24 27 or 30 bit RGB for color cameras If 8 24 bit are selected the user may select the upper middle or lower bits Users Manual PC Output 720p 60Hz HDMI Output Flip the image may be flipped horizontally and or vertically Rotation the image may be rotated by 90 180 and 270 degrees HDMI output this configuration is available only on Y cameras PC output the images are displayed on the computer video HDMI output the images are displayed on the HDMI output HDMI format not all the HDMI devices support the available resolu
5. z ee The apps listed below can transfer documents between your iPad and this computer E es a Apps MI Documents ps STORE 9 FileApp 2012 10 29 11 33 53 10 29 12 11 34 AM 246 2 MB Tunes Store 2012 11 08 07 40 16 Today 7 40 AM 76 1 MB iTunes Match Google Earth gt 2012 11 08 07 46 38 Today 7 49 AM 455 2 MB Purchased Gaana lt SHARED QQ Home Sharing PLAYLISTS 2 90 s Music Z Classical Music Z Music Videos 7 My Top Rated lt S Addin Save to 4 Top 25 Most Played Capacity 28 54 GB Audio Photos Apps 5 2 GB 0 27 GB 3 4 GB Users Manual
6. B Duplex half duplex lt MTUBAS Ts ET RL T Jumbo 9000 Custom Cancel OK 4 Change Configure from Automatic to Manual and modify the MTU to a value larger than 1500 Configuring Jumbo packets on the camera 1 From the Motion Inspector System menu select Options 2 If the Ethernet datagram size is set to optimal there is no need to change it otherwise select any size that is smaller than the value selected in the network adapter configuration NOTE in some network environments the maximum datagram size might be not supported and the cameras may time out and or behave in a strange way To avoid that reduce the datagram size on both the adapter and the camera 18 Users Manual Motion Inspector 3 2 Cameras Every detected camera is listed as a large icon button see below RESET Y3 53 Camera MotionPro Y8 S3 SN 28 1211 0209 IP 10 10 10 208 SNM 255 255 255 0 Color GE e Info click the info button to show the camera information e Reset if this option is selected the camera configuration is reset when the camera is open Users Manual 19 Motion Inspector 3 3 Wrong Camera IP address If the camera IP address and the computer IP address are not compatible the camera button is shown with a red warning message see below MotionPro Y4 S1 SN 19 1211 3170 IP 10 10 10 172 SNM 255 255 255 0 Color GE To configure the camera w
7. camera and sent to the driver The driver decodes the images before displaying them Center click Center to center the grid in the full resolution window Reset click Reset to set the grid size to the maximum Users Manual 25 Motion Inspector 3 8 1 Y7 NX7 and Y8 NX8 resolution 1920 x 1080 e Select one of the three available resolutions e Select one of the Dynamic Magnification values e Select Dynamic Mag ON OFF to activate or deactivate the magnification 26 Users Manual Motion Inspector 3 9 Buffer size e Click the plus or minus buttons to increase or decrease the values of buffer size and pre trigger e Click the BROC button to activate the configuration of the BROC length This option is available only if the camera firmware supports the AUTO BROC 3 9 1 Burst Record on Command BROC In BROC mode the memory segment size is set in the Length field and divided into sub segments each sub segment size is set in BROC Length When the acquisition is started the camera acquires in circular mode starting from the first sub segment When the event trigger occurs the camera completes the acquisition and start acquiring in the following sub segment This step is repeated until the memory segment is filled 3 10 Sync In The camera Sync source may be configured If an external sync source is detected by the camera the user may select one of the external modes otherwise only
8. express written permission of Integrated Design Tools Inc 2 Users Manual Motion Inspector Table of Contents 1 TERMS AND CONDITIONS ss sss sss sss sese senenn nenen nenen 5 2 SYSTEM OVERVIEW count 6 2 1 SUPPORTED PLATFORMS cccccncoccccnnnncncnnnnnanononoconononnnononnnnanccnnonancnononaninanonaninas 6 2 2 SUPPORTED CAMERAS A E A 7 2 3 HOW TO DISABLE THE USER ACCOUNT CONTROL ON WINDOWS UAC 8 2 4 HOW TO CONFIGURE THE WINDOWS FIREWALL 00seececeeeeeeeeeeeseeeeeeeeeeeeeees 9 2 4 1 How to add Motion Inspector to the list of allowed programs sss sees 9 2 4 2 How to disable the Windows firewall ococccccccncccncncicicicicicinicinonicinnnncnnnonos 11 3 MOTION INSPECTOR ancaccccconononononnanononancnonananonanananananananananananananasa 13 3 1 SYSTEM MENU ia 14 3 1 1 Camera enumeration DUO eee eee eee 14 0 E TTT Te eea 15 3 1 3 Large datagram size Jumbo packets sese e sese essere seer ener 17 3 2 GAMERAS tesa fies ots cece oe en Tate ea a ca E EA 19 3 3 WRONG CAMERA IP ADDRESS e ee nana nono nnanccnnnnaninans 20 3 4 EDIT CAMERA NAME AND IP ADDRESS ee 21 3 5 CAMERA OPERAT ON e a a a a 22 3 6 FRAT CPS L EET T HEN ET 23 3 7 EXPOSURE EAA ie cet oe eee EAE A NAE EEA E 24 CATA MRE S lt 102 STs le Es silent EE E tera EO EA te ee A sa 24 Dle ANULO EXPOSUIC aia ic 24 3 8 RESOLUTION cornada tddi 25 3 8 1 Y7 NX7 and Y8 NX8 resolution 26 3 9 BUEFER SIZE ainia dd ia 2
9. 7 3 9 1 Burst Record on Command BROC sees 27 3 10 SAN IN a 27 Ble TRIGGER Nit TTT 28 3 11 1 Moton MUI iii lap 28 E Da EE IE a a a a 28 3 12 1 Pixel depth Flip and HDMI sss sese eee 29 3 12 2 image sree CT 30 3 13 COLOR BALANCE TTT 31 Sd EOOKUP TABLES TUTO 32 S152 HISTOGRAM i casi a da heh ites 33 31 67 RESET ont a AN ak T 33 Ka IA eel E ORO 33 3 18 ADVANCED CONFIGURATION 34 3 19 ACQUIRE IMAGES ccocccccccccnnccccnccnoncnnonannnnnnononanno narran anna nn nenn narra nan rana ra nn 35 3 20 PLAYBACK IMAGES iess szcscteotesestecviceestovesttedaazedsdosdsdaadtaadsfibteantevdsigessteetoteeteies 36 3 21 MULTIPLE ACQUISITIONS cccccccccecceeseeceeeeeeseeeueueeseeceeeeeeseeeeeceeeeeeeeesaeaeaens 37 3 223 lt SAVEIMAGES ut 38 3 23 MULTIPLE CAMERA SYSTEM SD acrilico 39 3242 CID DISPLAY TTT TTT 40 3 25 BDASYNCHRONIZATION cid 41 3 20 ID TRIGGER iia a ad ii 42 4 MOTION VIEWER assi 43 4 1 OVERVIEW A aa 04 i A 43 4 2 OPEN A RAW SEQUENCE occccocccccccnnnccccnnnncncnnnnconononononononnnancnnnnancnononaccnnnonans 44 4 3 CONFIGURE SEQUENCE PARAMETERS ccccececseeeeseceeueeuceesuueuseeeueauseeseeaaeees 45 Users Manual Motion Inspector 4 4 CONVERT A RAW SEQUENCE eee 45 44 1 SAV lt lt ected hs iret iS hy Trade tosh LOA MN eevee ana MIG A Maat aes 47 AO MOV FORM TTT THT ten Aint Mee A Aas adres 47 4 5 CONVERT IN BATCH MODE ccccececcceeececeeeueceseueeucessuueueessueuaeeueueua
10. Windows Firewall Allow a program or feature Windows Firewall can help prevent hackers or malicious software from gaining access to your through Windows Firewall computer through the Internet or a network Change notification settings How does a firewall help protect my computer LS Turn Windows Firewall on or What are network locations off L Restore defaults Update your Firewall settings L Advanced settings Windows Firewall is not using the recommended settings to protect your Troubleshoot my network computer Use recommended settings What are the recommended settings m Y Home or work private networks Connected a Networks at home or work where you know and trust the people and devices on the network Windows Firewall state Off Incoming connections Block all connections to programs that are not on the list of allowed programs ee also a E A Active home or work private networks Ea IDT internal Action Center Network and Sharing Center Notification state Notify me when Windows Firewall blocks a new program From the options list on the left select Advanced Settings and open the Windows Firewall and advanced security window Users Manual 11 Motion Inspector File Action View Help es 0l 6 Windows Freva with Advan ET S Inbound Rules E3 Outbound Rules Mu Connection Security Rules gt Ml Monitoring Export Policy Overview Restore Default Policy Domain Profile
11. a r ih i T eee _ q w 7 j i oF Tw l A F y a 1 j B R J da a 4 es 7 T T a D ie h PR E N dl CA N A e h S E N 3 d e s F KZ PAT i A a _ X wi ie E f wa seda e Motion Inspector Cross platform User Manual for Windows MAC OS X iOS and Linux Motion Inspector Software Release 1 02 Document Revision December 2013 Products Information http www idtvision com North America 1202 E Park Ave TALLAHASSE FL 32301 United States of America P 1 850 222 5939 F 1 850 222 4591 llourenco idtvision com Europe via Pennella 94 38057 Pergine Valsugana TN Italy P 39 0461 532112 F 39 0461 532104 pgallorosso idtvision com Eekhoornstraat 22 B 3920 Lommel Belgium P 32 11 551065 F 32 11 554766 amarinelli idtvision com Copyright Integrated Design Tools Inc The information in this manual is for information purposes only and is subject to change without notice Integrated Design Tools Inc makes no warranty of any kind with regards to the information contained in this manual including but not limited to implied warranties of merchantability and fitness for a particular purpose Integrated Design Tools Inc shall not be liable for errors contained herein nor for incidental or consequential damages from the furnishing of this information No part of this manual may be copied reproduced recorded transmitted or translated without the
12. ad directory The RAW sequence can be converted later with the Motion Viewer Save JPEG not supported by all the cameras the images are downloaded in JPEG format and saved in a folder created in the download directory Save HDMI not supported by all the cameras the images are sent to the HDMI output at the maximum speed supported by the HDMI device Users Manual Motion Inspector 3 23 Multiple camera system 3D l l P Y4 S3 Camera x Y4 S1 Camera M 3 Mo 4 S1 Two cameras may be simultaneously operated e Connect the cameras and run Motion inspector e Click the 3D buttons of the camera you wish to open e Click one of the camera buttons Users Manual Motion Inspector 3 24 3D display 40 Rel meea 7 aa a Anaglyph B A Cam A the image from camera A is displayed Some parameters such as Color Balance are updated on camera A only Cam B the image from camera B is displayed Some parameters such as Color Balance are updated on camera B only Cam AB the images from camera A and camera B are combined in different ways Interlaced even rows are taken from one camera odd rows are taken from the other camera Anaglyph the red cyan anaglyph is generated by taking the red channel from one camera and the green and blue channels from the other camera Superposed the images are superposed with alpha channel Vertically tiled A over B the
13. ange is from O no filter to 5 full filter Denoise adds a filter that removes noise from the image Anti Alias Gaussian add a Gaussian blur filter to the image The range goes form 0 to 16 Sharpen Threshold the threshold value used by the sharpening filter Calibration parameters background and pixel sensitivity correction PSC may be enabled and disabled If the camera supports current conditions calibration the user may calibrate the camera and acquire background in optimal conditions Users Manual Motion Inspector 3 19 Acquire Images Arm Pause If the camera is armed and ready for triggering the red Trigger button on the bottom gray bar is enabled The trigger may be activated in two ways Software click the trigger button to generate a software trigger Hardware through a signal to the trigger in BNC connector When the trigger occurs and the camera completes the acquisition the playback page is activated Users Manual 35 Motion Inspector 3 20 Playback images Red recycle bin Acquisition List Black recycle bin 9 E Motion Ipsfector powered by IDT e i KR KA B 194 e Be lay ba 12 IZA Sa RA 136 Be ay U 5 l Se HO oe Red recycle bin double click this button to erase the camera memory and re arm the camera E Acquisition List each thumbnail shows a different memory segment with a single acquisition The acquisition info may be displ
14. ayed by clicking on the orange info button The amount of camera memory and free disk space is also displayed Black recycle bin an acquisition may be erased by dragging the icon into the recycle bin Slider move the slider back and forth to display a specific frame of the sequence Min and Max Handles the orange handles are useful to set the limits of playback Loop the loop button enables and disables the circular playback of the images Speed the speed button increases the playback speed 2x 4x 8x 12x 16x 20x 36 Users Manual Motion Inspector 3 21 Multiple acquisitions After the playback click the gray left arrow located on the left side of the window The software automatically locates a new segment in camera memory and arms the camera If the camera memory is full a dialog box with options is displayed i If the memory is available the user may record multiple acquisitions playback and save them Motion Inspector powered by IDT The acquisitions are shown as thumbnails in the upper bar e Click the orange info button to display information about the acquisition e Click on the thumbnail to activate the acquisition and start the playback Users Manual 37 Motion Inspector 3 22 Save Images 38 Click the save button to download images from the camera Three options are available Save RAW default the images are saved in RAW format in a folder created in the downlo
15. eesenenanees 48 4 6 OPEN AND CONVERT A SEQUENCE OF IMAGES e 50 B MOTION INSPECTOR FOR IPADTM sss sss sss sss sese neee enne 51 5 1 OVERVIEW secs tests cosithoat tet o a 51 5 2 INSTALLING THE IMOTIONINSPECTOR APP e ee e 52 5 3 APPLICATION SETUP T 53 5 4 GAMERA CONTROLS dicas aran adi 942922754 53 5 5 DOWNLOAD IMAGES s eee ee 55 5 6 TRANSFER IMAGES WITH ITUNES eee e e 56 4 Users Manual Motion Inspector 1 Terms and Conditions For more detailed information see the Terms and Conditions as stated in the camera manual and the IDT web site Users Manual Motion Inspector 2 System Overview 2 1 Supported platforms Motion Inspector supports the following platforms e Microsoft Windows XP Vista 7 and 8 32 and 64 bits e Apple MAC OS X 10 6 Snow Leopard 10 7 Lion and 10 8 Mountain Lion e Apple iOS version 5 1 and later e Linux Ubuntu 12 04 LTS Precise Pangolin and Fedora 17 Beefy Miracle 32 and 64 bit The cross platform manual provides instructions on using Motion Inspector on the above platforms The icons below denote differences in setup procedures and commands between Windows OS X OS and Linux users BGB n D Users Manual Motion Inspector 2 2 Supported cameras Motion Inspector supports the Y series and N NR series camera models The table below shows the minimum firmware requirements for operating a camera with Motion Inspector
16. image from one camera is displayed on the top side of the window the image from the other camera is shown on the bottom side Horizontally tiled Side by Side the image from one camera is shown on the left side the image from the other camera is shown on the right side Users Manual Motion Inspector 3 25 3D synchronization A B Internal Users Manual Internal both the cameras run with internal sync source not synchronized Master Slave one camera s Sync out Master is connected to the other camera s Sync in Slave External both cameras require an external sync source that synchronizes both When the user selects on of the sync options the software automatically checks the connections and verifies if the scheme is correct 41 Motion Inspector 3 26 3D Trigger 42 If two cameras are connected in Master Slave mode and armed it s important that the trigger is hardware If the cameras are triggered through the software the red button each camera will receive the trigger at a slightly different time due to Ethernet not being a time based interface The slave camera is working from the master sync pulse i e it takes one frame every time the master sync pulse is received If this sync pulse then the slave camera will stop functioning as it will stay waiting for the sync pulse If the slave happens to get trigger first both cameras will end the acquisition although the resulting
17. indows Firewall is installed They communicate through the UDP network protocol and need to open listening ports to receive the images In most of the cases the windows firewall shouldn t be disabled Motion Studio should be added to the list of the allowed programs and some other parameters should be configured in the firewall especially with HG cameras 2 4 1 How to add Motion Inspector to the list of allowed programs When an Ethernet camera is operated for the first time the Windows firewall detects the attempt to communicate through the network and tries to block it The message below appears O Windows Firewall has blocked some features of this program Windows Firewall has blocked some features of Motion Inspector on all public and private networks O Name Motion Inspector Publisher IDT Inc Path C program files jdt motioninspector motioninspector exe Allow Motion Inspector to communicate on these networks Y Private networks such as my home or work network Y Public networks such as those in airports and coffee shops not recommended because these networks often have little or no security What are the risks of allowing a program through a firewall 5 Cana The software will be allowed to communicate through the network if both the private and public options are selected Then click the Allow access button If the User Account Control UAC is disabled or you don t check both the opt
18. ions you may still allow the communication through the firewall e From the control panel start the Windows Firewall and select Allow a program or feature through Windows Firewall e Scroll the list and make sure that Motion Studio is in and all the check boxes are selected see below Users Manual 9 Motion Inspector a 2 9 CANTA EXE Allow programs to communicate through Windows Firewall To add change or remove allowed programs and ports click Change settings What are the risks of allowing a program to communicate LS Change settings Allowed programs and features Name Home Work Private Public DJ iSCSI Service O Media Center Extenders Motion Inspector Motion Studio Image Acquisition and Processing Motion Studio Network Configuration O Netlogon Service Network Discovery O Performance Logs and Alerts readouttest exe Remote Assistance O Remote Desktop O Remote Desktop RemoteFX GO O moO D D DRS DSR DD S D D DS D DDS S 10 Users Manual Motion Inspector 2 4 2 How to disable the Windows firewall To disable the Windows firewall the user needs Administrative privileges The firewall separately manages three profiles and it should be disabled on all of them e Domain profile e Private Profile e Public Profile From the Control Panel open the Windows Firewall dialog box Control Panel H s e Help protect your computer with
19. ith a correct IP address 20 Click the camera button Enter the correct values of IP address and subnet mask Motion Inspector suggests a value that is compatible with the computer IP address Click OK Wait a few seconds the camera needs to restart Edit Camera IP Address Y Users Manual Motion Inspector 3 4 Edit camera name and IP address Click the info button on the camera icon Cones ror Name IP Address Subnet Mask Model Serial Number Color Hardware Revision Firmware Versions MAC Address Minimum Exposure Internal Clock IRIG Enabled Plus 10 10 10 208 255 255 255 0 MotionPro Y8 S3 28 1211 0209 Yes 9 J 140 152 820 1 us 186 66 MHz Yes Yes Click on the name the IP address or the subnet mask and modify the value Click Exit to confirm the changes Users Manual 21 Motion Inspector 3 5 Camera operation 22 Click the camera button and the camera will be armed and ready for acquiring The camera parameters may be configured by clicking the buttons with orange text on the top and bottom bars B Motion Ins A Sa acbeth ColorChecker Color Rendition Chart O Back button Click the Back button to close the camera and return to the camera enumeration view Users Manual Motion Inspector 3 6 Rate fps Click the Plus and minus buttons to increase or decrease the camera frame rate Click or
20. pector Users Manual 53 Motion Inspector iMotion Inspector TION The top and bottom buttons control the camera parameters Exposure frame rate resolution color balance while the record button sends a trigger to the camera and acquires the images 54 Users Manual Motion Inspector 5 5 Download Images Once the images are acquired the playback page is open iMotion Inspector 00000000 a a e ee er es gt e Click the bottom bar arrow buttons to playback the images s Use the black and white handle to navigate in the images sequence e Use the Orange handles to select the start and stop frames e Click the Disk button to save the images in RAW format Jpeg format if supported or output the images to the HDMI output at the max possible speed up to 60 fps Users Manual 55 Motion Inspector 5 6 Transfer images with iTunes Once the images are saved in RAW or JPEG format to the iPad they may be transferred to the MAC with the File Sharing tool of iTunes e Run iTunes e Select the iPad from the list of devices and select the Apps tab e Scroll down to File Sharing select iMI and a list of the acquisition folders will appear Every folder name contains the date and the hour when it has been saved e Click the Save to button and select the destination folder en Tunes Pa Q Search Apps ee LIBRARY Summary Info E Music Movies TVShows Books Photos
21. s Save Image configuration Playback buttons Loop Speed e Use the playback buttons to playback the sequence in both directions e Use the slider to select a single frame and the Min and Max handles to select a start and a stop point e Click the Loop icon to activate and deactivate the circular playback of the images e Click the speed button to increase the playback speed to 2x 4x 8x 12x 16x 20x e Click the Zoom icon to set the image zoom e Click the Image icon to open the image parameters configuration e Click the Save icon to convert the sequence 44 Users Manual Motion Inspector 4 3 Configure sequence parameters The parameters that are not applied to the RAW image may be edited before converting the sequence Pixel Depth raw images re saved with native pixel depth 10 or 12 bit Once open the output pixel depth may be configured White Balance the procedure is described in the Motion Inspector topic Image parameters CFA Filter Color Filter Array the range is from 0 no filter to 4 linear interpolation Anti Alias Gaussian add a Gaussian blur filter to the image The range goes form 0 to 16 Sharpen and threshold adds a sharpening filter to the image The range is from 0 0 to 1 0 with 0 1 steps Gamma adds a gamma correction to the image The range is from 0 5 to 2 0 with 0 1 steps Brightness it changes the image brightness The range is from 0 25 to 0 25 Contrast
22. sequence may be a few frames out due to the timing difference of the trigger being received For hardware triggering use the push button connected via a T piece to both trigger inputs of the cameras and ensure that switch closure is set as the trigger type in the software If you are still having problems with the trigger cable cut the cable near the T piece strip away the outer and trigger by touching the two connections the core to the shield together Users Manual Motion Inspector 4 Motion Viewer 4 1 Overview The Motion Viewer lists the acquisition saved in the hard disk and shows a preview of each folder as a thumbnail A Motion Viewer powered by IDT e Browse click the button to select the path of the download folder e Change display filter click the black folder icon and select Show RAW files or Show Image files with or without thumbnails e Conversion batch click the batch icon to open the batch dialog and convert more than a sequence e Refresh click the button with the two arrows to refresh the thumbnail list s Open a RAW sequence do a single click on the thumbnail to open the sequence e Delete a RAW sequence drag the thumbnail to the recycle bin and release the mouse button Users Manual 43 Motion Inspector 4 2 Open a RAW sequence Motion Viewer powered by IDT a s eiere P gitilan T 580 009 5 9 0 036
23. spector e Select the File type the codec if available and the other parameters e Click Convert to start the conversion Users Manual 49 Motion Inspector 4 6 Open and convert a sequence of images e Select the Show Image Files option from the black folder icon e Click on one of the thumbnails and open a sequence e Use the slider and the playback controls to review the images e Click the Disk icon to save the images in a different format 50 Users Manual Motion Inspector WA 5 Motion Inspector for iPad 5 1 Overview Motion Inspector for iPad iMotionInspector or MI in this manual is a Wi Fi app now available on the iTunes store for iOS 5 1 and 6 0 It provides a wireless keypad to control the Y NR and NX series cameras The software interface resides on the Apple device and provides control of the camera independent of a computer insuring maximum portability The camera models that are supported by the app are listed in the topic 2 2 of this manual Users Manual 51 Motion Inspector 5 2 Installing the iMotionInspector App The software interface is free for download at the iTunes store https itunes apple com us app imotioninspector id574387894 mt 8 It may be downloaded via iTunes or directly from your iPad To do that open the App Store and search for iMotionInspector Follow the on screen instruc
24. tap on the rate value to open the touchpad and manually set the frame rate The touchpad may be used for the configuration of any other parameter Users Manual 23 Motion Inspector 3 7 Exposure Click the plus or minus buttons to increase or decrease the exposure by one half of f stop Click or tap on the exposure value to open the touchpad see above 3 7 1 Low Light Click the low light button to set the frame rate to 30 fps and automatically increase the exposure to the maximum Click the low light button back to set exposure and rate to their original values 3 7 2 Auto Exposure e Click the AE button to start Auto Exposure configuration e Move the orange grid or use the handle to resize it or click Reset to set the grid size to the maximum or click Center to center the grid e Click Apply to send the parameters to the camera and starts acquiring in Auto exposure mode 24 Users Manual Motion Inspector 3 8 Resolution 1024 x 720 beth ColorChecker Color Rendition Chart Move and or resize the grid with the handle or select one of the preset resolutions Display Full or decimated if the resolution is Decimated the images are compressed in the camera before the transmission to the driver If the resolution is Full the images are not compressed and are transmitted in their original size JPEG Encode if the option is selected the images are encoded in JPEG format in the
25. the color balance tables file is installed The tables are Day Light LED 6000K Tungsten and HMI and correspond to the correct balancing for different light source types Users Manual 31 Motion Inspector 3 14 Lookup Tables LUT 32 The lookup table LUT transformations are basic image processing functions that you can use to improve the contrast and the brightness of an image by modifying the dynamic intensity of region with poor contrast LUT transformations can highlight details in areas containing significant information at the expense of other areas The user may select a Lookup Table from a list of four pre defined tables or select User and drag the red circles to generate a custom LUT None Users Manual Motion Inspector 3 15 Histogram 0 11 Mono cameras the histogram is computed on the gray component Color cameras three histograms may be displayed e LUMA luminance e RGB Red Green and Blue components e YUV YUV components 3 16 Reset Click this button to reset the camera 3 17 Zoom Click the magnifier icon on the bottom left edge of the window to activate the zoom menu Fit the image is zoomed to fit in the window Users Manual 33 Motion Inspector 3 18 Advanced configuration 34 The advanced dialog box is activated from the main menu F E Advanced Parameters Y TNK Temporal Noise Killer adds a filter that removes temporal noise The r
26. the contrast value goes from 0 5 to 1 5 The default is 1 0 Hue color only it changes the image hue from 180 to 180 Saturation color only it configures the image saturation from 0 monochrome to 2 Lookup Tables four pre defined lookup tables may be applied to the raw file 4 4 Convert a RAW sequence To convert a sequence click the disk button Users Manual 45 Motion Inspector Reset Indexes s Image Name edit the image name e File Type TIFF BMP select one of the file types e Codec if the file type supports codec JPEG AVI and MOV the codec name and codec quality controls are enabled Click the left and right arrows to select the codec Click the plus and minus buttons to select the quality e From To Frame select the start and stop indexes e Output pixel depth if the file format supports large pixel depths the images may be saved with the original pixel depth otherwise only 8 and 24 bit are allowed e FPS select the output frame per second AVI MOV MRF and MCF only e Reset Indexes if this option is selected negative indexes are reset and started from 0 e Delete RAW file if this option is selected the RAW file is deleted after the conversion e Save click this button to start the conversion 46 Users Manual Motion Inspector 4 4 1 AVI Format The Audio Video Interleaved AVI format is supported only in Windows The first codec of the list is alwa
27. tions If 720p Overlay is selected some of the camera parameters are displayed on the video 29 Motion Inspector 3 12 2 Each parameter may corresponding label 30 Image parameters Gain the sensor gain values are 1 00 default 1 41 2 00 and 2 82 Sharpen adds a sharpening filter to the image The range is from 0 0 to 1 0 with 0 1 steps Gamma adds a gamma correction to the image The range is from 0 5 to 2 0 with 0 1 steps Brightness it changes the image brightness The range is from 0 25 to 0 25 Contrast the contrast value goes from 0 5 to 1 5 The default is 1 0 Hue color only it changes the image hue from 180 to 180 Saturation color only it configures the image saturation from 0 monochrome to 2 CFA Fuilter color only the range is from 0 no filter to 4 linear interpolation Single Double exposure the cameras can operate in single or double exposure be directly entered with the touchpad by clicking on the Users Manual Motion Inspector 3 13 Color Balance iretagMacbeth ColorChecker Color Rendition Chart e Click the target button to activate the cross target cursor e Click on a point of the image to calculate the white balance parameters e Click Reset to set the gain values to 1 e Click the plus and minus buttons to tune the gains List of color balance tables a list of pre defined color balance tables may appear below the Reset button if
28. tions and install the app After the install the icon iMI will appear on your iPad see below 7 sS App Store Game Center FaceTime nmm c Camera Photo Booth Photos A TE x HD Calculator Newsstand Music J me ZI R SC iBooks Safari Settings 52 Users Manual Motion Inspector 5 3 Application setup Upon the installation of the MI app follow the instructions below to start the communication between the iPad and the camera e Connect the camera to one of the Ethernet sockets of a Wi Fi Access Point e Power up the camera and wait until the back Status light is green e Open the iPad settings and select the Wi Fi page Make sure that the Wi Fi Access Point is visible in the Network list and choose it enter a password if required Better if the Wi Fi connection is 5 GHz Settings wil ex Choose a Network La Bluetooth Alice 37277887 RS O SM Collutar Data Oil FASTWEB 2011 az Do Not Disturb OFF idtEurope az Notifications NETGEAR88 azo S General Y NETGEAR88 5G ar bon s0 Other gt Eg Brightness A Wallpaper Ask to Join Networks OFF led Picture Frame Gg Privacy CY Cloud Known networks will be prad automaticaly If no anman networks are avsilable you ml have 19 marmualy select a network IL Mail Contacts Calendars Fotos L Reminders a 5 4 Camera Controls The iMI interface is similar to the Windows and MAC versions of Motion Ins
29. to the Ethernet cameras If you select Broadcast the software will search for cameras from each adapter in your computer Network performance it s a delay added to the data transmission between the cameras and the computer If there is traffic in the local network click the right arrow to increase the value and avoid loss of data during communication Ethernet datagram size see below Users Manual 15 Motion Inspector Exposure format the exposure may be displayed in microseconds or in degrees shutter angle Background select the color or the background s Note on Motion Inspector for iPad 05 Some of the options above are not available on Motion Inspector for iPad e Download folder selection the images are downloaded in the app Documents folder e Acquisition folder name the names of the folders cannot be edited They are automatically generated with the date and the time 16 Users Manual Motion Inspector 3 1 3 Large datagram size Jumbo packets Some Giga Ethernet network adapters are able to send and receive large data packets The usual datagram size is 1500 bytes Large datagram packets called Jumbo packets are up to 9000 bytes If both the camera and the adapter can use jumbo packets the transfer speed is increased To activate jumbo packets do the following 3 1 3 1 Configuring Jumbo packets on the Network adapter Windows 1 From Windows Start menu open the Net
30. work Connections window and select the network adapter Right click and select the Properties menu item From the Properties dialog box click the Configure button From the network adapter configuration dialog select the Advanced tab r gg NVIDIA nForce Networking Controller 2 Properties Gener Avances Diver Ha Power Management The following properties are available for this network adapter Click the property you want to change on the left and then select its value on the right Property Value Flow Control Interrupt Moderation sum Offload 1514 bytes Ce Large Send Offload V1 IPv4 abies Large Send Offload V2 IPv4 Large Send Offload V2 IPv6 Network Address TCP Checksum Offload IPv4 TCP Checksum Offload IPv6 UDP Checksum Offload IPv4 UDP Checksum Offload IPv6 5 From the property list locate the Jumbo Packet item or anything similar to that and change the value from 1500 to the maximum 3 1 3 2 Configuring Jumbo packets on the Network adapter MAC OS X C 1 From the System preferences select Network Users Manual 17 Motion Inspector 2 Select the network adapter and click Advanced 3 Select the Ethernet page VAM Network Lala show ail Q deso Ethernet TCP IP DNS WINS 802 1X Proxies Ethernet Ethernet ID c8 2a 14 40 18 a8 Configure Manually eq Speed
31. ys Uncompressed AVI Other codec s are listed only if they are installed in the OS 4 4 2 MOV Format Windows the MOV format is supported in Windows only if Apple QuickTime is installed MAC OS X the MOV format is supported The Prores and some other codec s are available in the MAC version and may be downloaded from the Apple website ProApps QuickTime Codecs See the link below http support apple com kb DL1396 Users Manual 47 Motion Inspector 4 5 Convert in Batch mode 48 Click the batch icon to open the conversion batch dialog box A Raw Conversion Batch KAI Reset Indexes 01 18 0912 0418 002 02 2011 12 14 17 38 01 03 2011 12 21 11 39 36 04 2011 12 21 11 42 32 05 2011 12 21 14 43 40 06 2011 12 21 14 51 09 07 2011 12 22 08 32 28 08 2011 12 22 08 42 56 09 2011 12 22 11 35 13 10 2011 12 22 17 29 23 nmm anns 12 20111121 105908 13 20111121 110243 MotionPro Y3 S1 MotionPro Y3 S1 MotionPro Y4 S1 MotionPro Y4 S1 MotionPro Y4 S1 MotionPro Y4 S1 MotionPro Y4 S1 MotionPro Y4 S1 MotionXtra NXT4 S3 MotionPro Y4 S1 MotionPro Y4 S3 MotionPro Y4 53 MotionPro Y4 53 P mas Select the sequences from the list and use the up and down arrows to scroll the list Click Select all to select all the sequences in the database and Deselect all to desect them Click Browse to change the destination folder Users Manual Motion In

Download Pdf Manuals

image

Related Search

Related Contents

カタログpdf  Suunto GPS POD  L`archéologie préventive  plafonds 4 a.  Motorcycle-All - Nitrous Express  AVF EPL000PB flat panel wall mount  Liebherr CBNesf 3913  Lipton Exclusive Selection Earl Grey  Planification familiale, un manuel a l`intention des prestataires de    

Copyright © All rights reserved.
Failed to retrieve file