Home
EATON 5S
Contents
1. Problem 1 The battery backup outlets 49 are not supplied with power 2 e The connected devices are not supplied when AC power fails 3 eAC power is available but the UPS operates on battery power 4 e Green button 6 flashes and audible alarm beeps every 3 seconds 5 eFault sign 42 appear on the LCD panel and audible alarm beeps continuously 6 eEcoControl outlets keep powered when main application Master outlet is stopped 614 06818 01 Diagnostic e Button 6 is not lite on e The devices are not connected to the battery backup outlets 49 e Circuit breaker 20 located at the rear of the UPS has been tripped by an overload on the UPS output e The UPS battery backup outlets are overloaded e A fault has occurred on the UPS The battery backup outlets are no longer supplied e EcoControl function is not activated or not properly set Solution e Press button 6 and check that it turns green e Connect the devices to the battery backup outlets 49 e Disconnect excess equipment and reset the circuit breaker by pressing the corresponding button e Disconnect excess equipment connected to the battery backup outlets 49 e Call post sales support e Activate or set properly EcoControl function using the software provided with the product 1 Conditions d utilisation e Cet appareil est une Alimentation Sans Interruption ASI con ue pour alimenter un ordinateur et ses p riph riques
2. connect e au r seau lectrique quel que soit l tat du bouton 6 A la premi re utilisation la batterie ne donne sa pleine autonomie qu apr s une recharge de 8 heures Pour conserver la meilleure autonomie il est conseill de laisser l ASI branch e en permanence sur le r seau lectrique Mise en marche de l ASI Appuyer sur le bouton 6 environ 1 seconde Prises prot g es contre les surtensions 49 non secourues Les appareils raccord s sur ces prises sont aliment s d s que le c ble d entr e 6 est branch sur une prise murale Le bouton 6 ne les commande pas Prises secourues 49 Les appareils raccord s sur ces prises sont aliment s d s que le bouton 6 est allum en vert voir figure E Ces prises peuvent tre mises en marche m me si l ASI n est pas connect e au r seau lectrique bouton 6 clignotant 12 614 06818 01 Perturbation du r seau lectrique e Si la tension de ce r seau est mauvaise ou absente l ASI continue fonctionner sur batterie le bouton clignote en vert En mode normal l alarme sonore met un signal toutes les 10 secondes puis toutes les 3 secondes lorsque la fin d autonomie batterie approche En mode silence l alarme sonore met un bip au passage sur batterie e Si la dur e de la coupure du r seau lectrique d passe l autonomie batterie l ASI s arr te puis red marre automatiquement au retour du r seau lectrique Apr s d charge compl te quelques heures sont
3. des appareils de TV HI FI Vid o l exclusion de tout autre appareil lectrique clairage chauffage lectromenager e L ASI peut tre install e en position horizontale verticale eL O eL a LL 2 Description 6 Bouton MARCHE ARR T pour les prises secourues par batterie D filement Aow A a en DU r o D O C OS D sactivation d alarme LCD ASI en fonctionnement Mode AVR Mode batterie D faut interne Niveau de charge en sortie s EN Niveau de batterie Mesures en entr e Mesures en sortie Unit de mesure 0606690 i N gt kVA kW NJ Nu WIA eN l va anm mm Hz S981818 Prises Prises prot g es contre les surtensions 3960 Prises secourues par batterie o a Protection disjoncteur W Cordon d alimentation BDU vo do du wad a 44 Surge Protection ANSSI rua uomaa 88105 44 sma dwpeg Aenea WA 10 614 06818 01 3 Raccordement de I ASI e Raccorder l ASI 1 au r seau lectrique sur une prise murale avec terre I aide du cordon voir figure A e Connecter les prises des appareils critiques ordinateur cran modem sur les prises secourues par la batterie 19 et prot g es contre les surtensions voir figure B en ne d passant pas le courant indiqu en Amperes e Les autres appareils imprimante scanner fax peuvent tre branch s sur les pr
4. 44 Surge Protection Ju du y Uong Bin 4 ana dana Ansa J MU YU Y 14 614 06818 01 3 Conexiones del SAI e Conecte el SAI 1 al sistema de alimentaci n de CA mediante una toma de corriente de pared con toma de tierra utilizando el cable suministrado 6 v ase la figura A e Conectar los enchufes de los aparatos cr ticos ordenador pantalla m dem etc en las tomas alimentadas por la bateria 19 y protegidas contra las sobretensiones v ase la figura B no sobrepasando la corriente indicada en amperios e Tambi n pueden conectarse otros dispositivos impresora esc ner fax etc a las tomas de corriente de protecci n contra sobretensiones 49 v ase la figura B Las tomas de corriente de protecci n contra sobretensiones no pueden ser respaldadas con la alimentaci n de la bateria en el caso de corte de corriente nu Q Z a V LLI Protecci n de la linea de datos fax m dem red ethernet opcional La linea telef nica fax m dem red ethernet podra ser protegida contra las sobretensiones conectandose a trav s del SAI Para ello conectar la toma mural al SAI con el cable del equipo a proteger y por otra parte con un cable id ntico unir el SAl al equipo protegido como se indica en el dibujos C y D cable no suministrado Communicaci n USB Serie opcional El dispositivo SAI puede conectarse al ordenador mediante el cable USB 4 incluido v ase la figura C El software de Eaton UPS C
5. 6 25 Cito 455 C Sr to 131 F 0 to 85 0 to 2000 m O to 6562 ft UL 1778 FCC Part 15 Class B 382 x 87 x 250 15 04 x 3 43 x 9 84 10 24 x 3 43 x 9 84 e Weigth kg lb 5 9 13 0 9 7 21 4 11 6 25 6 Warning Output cables should not exceed 10m 32 81 ft length 614 06818 01 1 Operating conditions e This product is an Uninterruptible Power Supply UPS for computers and their peripherals television sets stereo systems and video recorders It must not be used to supply other electrical equipment lighting heating household appliances etc e UPS can be installed in horizontal vertical position aL O TT 2 Description 6 ON OFF button for the battery backup outlets var BA 7 Scroll down ss Mute alarm el U C Min eD D L so LCD UPS ON AVR mode Battery mode Internal fault Output load level Battery level NAN WAN C A Input measurements Output measurements N o Jo Measuring unit Min i M Hz AAA op E ol kVA Outlets Surge protection outlets Battery backup outlets Protection circuit breaker AC Input Cord NA 39006 BDU vo do du au a 44 Surge Protection ANS NSIS auu Y 40031014 88105 44 sma dropeg Veyan 6 614 06818 01 3 UPS connections e Connect the UPS 1 to the AC power system via a wall outlet with an earth connector using the attached cord see figure A e Plug critical equipment
6. B No caso de uma falha de energia as tomadas com protec o contra sobretens o n o s o apoiadas por energia da bateria Y ES g gt kea cc O A Liga o Modem Internet rede facultativa A linha modem ou rede Ethernet pode ser protegida contra as sobretens es se for ligada atrav s do UPS Para isso rigar por um lado a ficha mural ao UPS com o cord o do aparelho a proteger e por outro lado o UPS e esse aparelho com um cord o id ntico como indicado nas figuras C e D cord o n o fornecido Liga o USB facultativa O dispositivo UPS pode ser ligado ao computador utilizando o cabo USB 4 fornecido ver figura C O software Eaton UPS Companion pode ser descarregado de powerquality eaton com Para efeitos da garantia registe se em powerquality eaton com 4 Modo de funcionamento das tomadas Master e EcoControl A fim de limitar o consumo de energia dos dispositivos perif ricos scanner impressora no modo de espera a Eaton 5S est equipada com tomadas EcoControl dependentes da tomada Master ver figura B Quando a aplica o principal alimentada pela tomada Master computador estiver parada as tomadas EcoControl s o automaticamente desactivadas e os dispositivos perif ricos param A valida o e a configura o desta fun o desactivada por defini o s o feitas por interm dio da ferramenta de configura o integrada ao software Nota quando a fun o estiver activada n o conectar
7. aplica es cr ticas nas tomadas EcoControl Configura o dos limiares Uma configura o dos par metros padr o assegura o funcionamento correcto da fun o EcoControl Entretanto conforme o n vel de consumo da carga principal pode ser necess rio alterar o limiar de desencadeamento da fun o EcoControl utilizando o software de configura o fornecido com o ondulador e Certificar se inicialmente de que a fun o esteja bem activada no painel EcoControl function da ferramenta de configura o e Se os dispositivos perif ricos ligados nas tomadas EcoControl n o pararem quando a carga principal n o estiver em funcionamento normal ex durante uma hiberna o preciso aumentar o valor do limiar de detec o para o n vel High e Se o n vel de consumo nominal da carga principal estiver fraco e se as tomadas EcoControl pararem enquanto a carga principal estiver a funcionar normalmente preciso abaixar o valor do limiar de detec o para o n vel Low 614 06818 01 19 5 Configura o da UPS atrav s do LCD Solte o bot o de deslocar para baixo para seleccionar o menu E 2s M N C E mx gt IDU Y ES O m cc O O v Guarde o novo valor e O LCD desliga se n o houver actividade durante 3 minutos 6 Utiliza o Carregamento da bateria A UPS carrega a sua bateria quando ligada rede el
8. bateria 4 El bot n verde 6 parpadea y la alarma emite un pitido audible cada tres segundos 5 e Aparece una se al de error 42 en la pantalla LCD y la alarma emite un pitido audible continuo 6 eLas tomas EcoControl mantienen el suministro mientras que la aplicaci n principal toma Master est detenida 614 06818 01 Diagn stico e El interruptor 42 no esta encendido e Los aparatos no estan conectados a las tomas auxiliadas 9 e El disyuntor 20 situado en la parte trasera del SAI se ha activado debido a una sobrecarga en la toma del SAI e El SAI recibe una sobrecarga en las tomas auxiliares 9 e El SAl tuvo un desperfecto Las tomas auxiliadas 9 no son alimentadas e La funci n EcoControl no est activada o no se ha configurado correctamente Soluci n e Accione el interruptor 42 y compruebe que est encendido en verde e Conecte estos aparatos a las tomas auxiliadas 9 e Desconecte dicho aparato de la salida y rearme el interruptor autom tico 43 accionando su boton e Desconecte el aparato respectivo de las tomas auxiliares e P ngase en contacto con el servicio de posventa e Active o configure correctamente la funci n EcoControl mediante el software incluido 1 Condi es de utiliza o e Este aparelho um Uninterruptible Power Supply UPS concebida para alimentar um computador e os seus perif ricos aparelhos de televis o alta fidelidade v deo ex
9. clus o de qualquer outro aparelho el ctrico ilumina o aquecimento electrodom sticos e O UPS pode ser instalado na posi o horizontal vertical Y ES O cc O O 2 Descri o 6 Bot o ON OFF Ligar Desligar para as tomadas da reserva de bateria Po rr A Sai mam HH NA Deslocar para baixo OS Silenciar alarme LCD UPS Ligada Modo AVR Modo de bateria Falha interna N vel da carga de sa da N vel da bateria Medi es de entrada ML Medi es de sa da r r r o o mE Unidade de medic o Min Hz ol kVA EAN LI kW V008600D9D00 Tomadas Tomadas com protec o contra sobretens o Tomadas da reserva de bateria Protec o disjuntor A ES 09 voranoigabing 44 sna dopra Maneg WE Cabo de Alimenta o q X 44 surge Protec ara VU ypu a V gu 8 18 614 06818 01 3 Ligar a UPS e Ligue a UPS 1 ao sistema de alimenta o de CA atrav s da tomada de parede com liga o terra utilizando o cabo conectado 49 ver figura A e Ligar as fichas dos aparelhos cr ticos computador ecr modem nas tomadas protegidas pela bateria 49 e protegidas contra as sobretens es ver figura B sem ultrapassar a corrente indicada em Amperes e Outros dispositivos impressora scanner fax etc podem ser ligados s tomadas com protec o contra sobretens o 49 ver figura
10. computer monitor modem etc into the outlets 49 providing battery backup power and surge protection see figure B taking care not to exceed the rated current indicated in amperes e Other devices printer scanner fax etc can be connect to the surge protection outlets 49 see figure B The surge protection outlets are not backed up by battery power in the event of a power outage ENGLISH Optional Internet modem Network connection A modem or Ethernet data line can be protected against surges by connecting it via the UPS Connect the existing device cable between the wall outlet and the UPS and use a similar cable between the UPS and the device as indicated in figures C and D cable not supplied Optional USB connection The UPS device can be connected to the computer using the USB cable 4 supplied see figure C Eaton UPS Companion software is downloadable from powerquality eaton com Register for the warranty on powerquality eaton com 4 Master and EcoControl outlets operating procedure In order to limit energy consumption of peripherals scanner printer in standby mode the Eaton 5S is equipped with EcoControl outlets that are dependent on the Master outlet When the main device supplied by the Master outlet computer is shut down the EcoControl outlets are automatically deactivated and the peripherals shut down This function deactivated by default is validated and configured using the configuration tool
11. ctrica qualquer que seja o estado do bot o 6 Na primeira utiliza o a bateria disp e de toda a sua autonomia unicamente ap s uma recarga de 8 horas Para manter uma autonomia optimizada conv m deixar a UPS ligada em perman ncia rede el ctrica Coloca o em funcionamento do UPS Premer o bot o 6 durante 1 segundo Tomadas com protec o contra sobretens o 48 sem reserva de bateria Os aparelhos ligados nestas tomadas s o alimentados desde que o cabo de entrada e esteja ligado numa tomada de parede O bot o 6 nao as controla Tomadas protegidas 9 os aparelhos ligados nestas tomadas s o alimentados desde que o bot o 6 esteja aceso em verde ver figura E Estas tomadas podem ser colocadas em funcionamento mesmo se a UPS n o estiver ligada rede el ctrica bot o 6 a piscar 20 614 06818 01 Perturba o da rede el ctrica e Se a tens o da rede for deficiente ou ausente a UPS continua a funcionar com a bateria o bot o 6 pisca em verde Em modo normal o alarme sonoro emite um sinal cada 10 segundos em seguida cada 3 segundos quando se aproxima o fim da autonomia da bateria Em modo silencioso o alarme sonoro emite um bip quando passa para a alimenta o pela bateria e Se a dura o do corte da rede el ctrica for superior autonomia da bateria a UPS p ra e recome a a funcionar automaticamente quando a rede el ctrica for Y ES g gt a cc O A restabelecida De
12. integrated in the software Note when the function is activated do not connect critical applications to EcoControl outlets Threshold setup 614 06818 01 A default setup ensures the correct operation of the EcoControl function However depending on the consumption of the main load the trigger threshold of the EcoControl function may have to be modified using the configuration software supplied with the UPS e First make sure that the function is activated in the EcoControl Function tab of the configuration tool e f the peripherals connected to the EcoControl outlets do not switch off when the main load is not in normal operation ex when in standby mode the detection threshold value must be set to High e f the rated consumption level of the main load is low and the EcoControl outlets shut down when the main load is operating normally the detection threshold value must be set to Low 5 UPS setting through the LCD Release scroll down button to select menu aL L O TT N ss ns Un Save the new value e LCD shut off if no activity for 3 minutes 6 Operation Battery charge The UPS charges the battery as soon as it is connected to the AC outlet whether button 6 is pressed or not When used for the first time the battery will only provide its maximum performance after it has been charged for 8 hours It is recommended
13. ises prot g es contre les surtensions 48 voir figure B les prises prot g es ne sont pas secourues en cas de coupure de courant FRANCAIS Liaison Modem Internet r seau facultative La ligne modem ou r seau Ethernet peut tre prot g e contre les surtensions en la raccordant via l ASI Pour cel relier d une part la prise murale a I ASI avec le cordon de l appareil prot ger et d autre part l ASI cet appareil l aide d un cordon identique comme indiqu figures C et D cordon non fourni Liaison USB facultative L appareil ASI peut tre connect l ordinateur via le cable USB 4 fourni voir figure C Le logiciel Eaton UPS Companion peut tre t l charg depuis le site powerquality eaton com Enregistrement de la garantie sur le site powerquality eaton com 4 Mode de fonctionnement des prises Master et EcoControl Afin de limiter la consommation d nergie des p riph riques scanner imprimante en mode veille Eaton 5S est muni de prises EcoControl d pendantes de la prise Master voir figure B Quand l application principale aliment e par la prise Master ordinateur est arr t e les prises EcoControl sont automatiquement d sactiv es et les p riph riques s arr tent La validation et le param trage de cette fonction d sactiv e par d faut se font par l interm diaire de l outil de configuration int gr au logiciel Note lorsque la fonction est activ e ne pas connecter d applications c
14. n cessaires pour restaurer l autonomie complete Protection contre les surtensions Toutes les prises sont prot g es contre les surtensions Arr t des prises secourues 9 Appuyer plus de 2 secondes sur le bouton 6 7 D pannage Pour toutes informations consulter le site www powerquality eaton com ou notre Service Apr s Vente Sympt me e Les prises secourues 49 ne sont pas aliment es e Les appareils raccord s ne sont plus aliment s lors d une coupure du r seau lectrique e Le r seau lectrique est present mais l ASI fonctionne sur sa batterie e Le bouton vert 6 clignote et une alarme sonore met un signal toutes les 3 secondes e Le signal de d faut 2 appara t sur l afficheur LCD et une alarme sonore met un signal continu e Les prises ECoControl restent aliment es alors que l application principale prise Master est arr t e 614 06818 01 Diagnostic e Le bouton 6 n est pas allum e Les appareils ne sont pas raccord s sur les prises secourues e Le disjoncteur 20 place a l arri re de l ASI s est ouvert pour cause de surcharge excessive en sortie de I ASI e L ASI subit une surcharge sur les prises secourues 19 e L ASI a subit un d faut Les prises secourues ne sont plus aliment es e La fonction EcoControl n est pas activ e ou est mal param tr e Remede e Appuyer sur le bouton 6 et v rifier qu il s est allum en vert e Raccorder ces a
15. ompanion puede descargarse en powerquality eaton com Reg strese para disfrutar de la garant a en powerquality eaton com 4 Instrucciones de funcionamiento de las tomas Master y EcoControl Para reducir el consumo de energia de los perif ricos scanner impresora en modo de espera Eaton 5S cuenta con tomas EcoControl dependientes de la toma Master v ase figura B Cuando la aplicaci n principal alimentada por la toma Master ordenador se para las tomas EcoControl se desactivan autom ticamente y los perif ricos se paran La validaci n y configuraci n de esta funci n desactivada por defecto se realiza mediante la herramienta de configuraci n integrada en el software Nota Cuando la funci n est activada no conecte aplicaciones cr ticas a las tomas EcoControl Configuraci n de los umbrales La configuraci n por defecto asegura el correcto funcionamiento de la funci n EcoContol Sin embargo seg n el nivel de consumo de la carga principal puede que sea necesario modificar el umbral de activaci n de la funci n EcoControl mediante el programa de configuraci n proporcionado con el ondulador e Aseg rese primero de que la funci n est activada correctamente en la opci n EcoControl function de la herramienta de configuraci n e Silos perif ricos conectados a las tomas EcoControl no se paran cuando la carga principal no est en funcionamiento normal p ej durante el modo de espera es necesario aumentar el val
16. or del umbral de detecci n al nivel High e Siel nivel de consumo nominal de la carga principal es bajo y las tomas EcoControl se paran cuando la carga principal funciona correctamente es necesario disminuir el valor del umbral de detecci n al nivel Low 614 06818 01 15 5 Ajuste del SAI en la pantalla LCD rn Suelte el bot n de desplazamiento para seleccionar el men nu EE pal o Il E G Z a Y Lu v Guarde el nuevo valor e El panel LCD se apagar si no registra actividad en un intervalo de 3 minutos 6 Utilizaci n Carga de la bater a El SAI carga su bater a en el momento en que se conecta a la red el ctrica sin importar el estado del interruptor 6 Al utilizar por primera vez la bateria proporciona su total autonomia s lo despu s de una recarga de 8 horas Para mantener la mayor autonomia se aconseja dejar el SAI conectado permanentemente a la red el ctrica Puesta en marcha del SAI Pulsar el interruptor 6 1 segundo Tomas de corriente de protecci n contra sobretensiones 49 sin bater a auxiliar Los aparatos conectados a estas tomas son alimentados a partir del momento en que el cable de entrada 7 se conecta a una toma mural No se pueden desconectar mediante el interruptor 6 Tomas auxiliadas 49 Los aparatos conectados a estas tomas son alimentados a partir del momento en que el interruptor 6 e
17. pois de totalmente descarregada s o necess rias algumas horas para restabelecer a autonomia completa Protec o contra sobretens o Todas as tomadas incluem protec o contra sobretens o Paragem das tomadas protegidas 9 Premer durante mais de 2 segundos o bot o 6 7 Resolu o de problemas Para qualquer informa o consultar www powerquality eaton com o nosso servi o P s Venda Sintoma 1 As tomadas protegidas 49 nao sao alimentadas 2 eQOsaparelhos ligados n o s o alimentados durante um corte da rede el ctrica 3 A rede el ctrica est presente mas a UPS funciona com a bateria 4 e Flashes do bot o verde 6 e alarmes ac sticos bip a cada 3 segundos 5 eNo painel LCD surge o s mbolo de falha e o alarme ac stico bip soa continuamente 6 eAs tomadas EcoControl continuam a ter alimenta o mesmo quando a aplica o principal tomada principal est parada 614 06818 01 Diagn stico e O bot o 6 n o est aceso e Os aparelhos n o est o ligados as tomadas protegidas 19 e O disjuntor 20 na parte de tras da UPS foi activado por uma sobrecarga na saida da UPS e A UPS esta em sobrecarga nas tomadas protegidas 9 e A UPS nao esta a funcionar correctamente As tomadas protegidas deixaram de ser alimentadas e A fun o EcoControl nao esta activada ou nao esta programada de forma correcta Solu o e Premer o bot o 6 e verificar se e
18. ppareils sur les prises secourues 9 e D brancher l appareil en cause en sortie et r armer le disjoncteur en appuyant sur son bouton e D brancher l appareil en cause des prises secourues 19 e Faire appel au service apr s vente e Activer ou param trer correctement la fonction EcoControl en utilisant le logiciel fourni avec le produit FRANCAIS land E G a Y Lu 1 Condiciones de uso e Este aparato es un Sistema de Alimentaci n Ininterrumpida SAI disenado para alimentar principalmente un ordenador y sus perif ricos aparatos deTV HI FI V deo excepto cualquier otro tipo de aparato el ctrico alumbrado calefacci n electrodom sticos etc e El SAI puede instalarse en posici n horizontal vertical 2 Descripci n 6 Bot n de ENCENDIDO APAGADO para las tomas de la bateria auxiliar a avr A c ass SHAH Min TTT sa Desplazamiento hacia abajo OD Silencio de alarma LCD SAI conectado Modo AVR regulaci n autom tica de voltaje Modo de bateria Fallo interno ANP AVR AN sl NEN r r H H H sa RA EAN Ly kW Nivel de carga de salida Nivel de la bateria Mediciones de entrada Mediciones de salida Unidad de medici n 0606069 OO Tomas Tomas de corriente de protecci n contra sobretensiones Tomas de la bateria auxiliar NA 300 Protecci n disyuntor Cable de entrada NU W iu wad a Late
19. ritiques sur les prises EcoControl Param trage des seuils Un param trage par d faut assure le bon fonctionnement de la fonction EcoControl Cependant selon le niveau de consommation de la charge principale il peut tre n cessaire de modifier le seuil de d clenchement de la fonction EcoControl en utilisant le logiciel de configuration livr avec l onduleur e S assurer tout d abord que la fonction soit bien activ e dans le volet Fonction EcoControl de l outil de configuration e si les p riph riques connect s sur les prises EcoControl ne s arr tent pas quand la charge principale n est pas en fonctionnement normal ex pendant une mise en veille il est n cessaire d augmenter la valeur du seuil de d tection au niveau Haut e si le niveau de consommation nominal de la charge principale est faible et que les prises EcoControl s arr tent alors que la charge principale fonctionne normalement il est n cessaire d abaisser la valeur du seuil de d tection au niveau Bas 614 06818 01 11 5 R glage de l ASI l aide de l afficheur LCD Rel cher le bouton de d filement pour s lectionner le menu ru s MEA eL O eL am LL Dl HL c Enregistre la nouvelle valeur e L afficheur LCD s teint automatiquement apr s 3 minutes d inactivit 6 Utilisation Charge batterie L ASI charge sa batterie d s qu elle est
20. st devidamente aceso em verde e Ligar esses aparelhos as tomadas protegidas 19 e Desligar o aparelho ligado a sa da e rearmar o disjuntor premendo o respectivo bot o e Desligar das tomadas protegidas 19 o aparelho ligado e Dirigir se ao servi o p s venda e Active ou programe de forma correcta a fun o EcoControl utilizando o software fornecido com o produto 21 www eaton com E at N 614 06818 01 Powering Business Worldwide
21. st encendido en verde ver el dibujo E Estas tomas se pueden poner en funcionamiento a n cuando el SAI no est conectado a la red el ctrica interruptor 6 parpadeando 16 614 06818 01 Perturbaci n de la red el ctrica e Sila tensi n de esta red es defectuosa o est ausente el SAI sigue funcionando con la bateria el interruptor 6 parpadea en verde En modo normal la alarma ac stica emite un sonido cada 10 segundos y luego cada 3 segundos cuando la bateria se acerca al final de su autonomia En modo silencio la alarma ac stica emite un bip cuando la bateria toma el relevo e Si la duraci n del corte de la red el ctrica sobrepasa la autonomia de la bater a el SAI se detiene y luego se enciende autom ticamente cuando vuelve la red el ctrica Ms Z Z V LLI Tras su descarga completa se necesitaran varias horas para restaurar su autonomia completa Protecci n contra sobretensi n Todas las tomas incluyen la funci n de protecci n contra sobretensi n Interrupci n de las tomas auxiliadas 49 Presionar durante m s de 2 segundos el interruptor 6 7 Reparaci n Para cualquier informaci n consultar el sitio www powerquality eaton com o nuestro servicio de posventa S ntoma 1 eLas tomas auxiliadas 9 no son alimentadas 2 eLos aparatos conectados no son alimentados durante un corte de la red el ctrica 3 eLa red el ctrica est presente pero el SAI funciona con su
22. th applicable regulations To remove the battery shut down the UPS button 6 OFF remove the power cord and proceed as indicated below Battery change Battery change Press and slide e Warning take care not to inverse the polarity red and black when connecting the battery as this will destroy the device 1000 1500 Press and slide 4 614 06818 01 Technical characteristics Eaton 5S 700 e UPS power 700 VA 420 W e Nominal input voltage e Input frequency e Voltage frequency of battery backup outlets 19 in battery mode e Total output current for all outlets 10 A max e Output current of battery backup 6 1 A max outlets e Leakage current e Input protection breaker e Transfer time e Telephone Data surge protection e Sealed lead acid battery 12V 9Ah e Automatic battery test e Average battery life e Operating temperature e Storage temperature e Operating relative humidity e Operating elevation e Safety standards e Electromagnetic compatibility standards e Dimensions mm inch 10 A resettable circuit 260 x 87 x 250 1000 1500 1000 VA 1500 VA 600 W 900 W 93 V 138 V 50 60 Hz 46 70 Hz working range 115 V 15 20 60 Hz 1 Hz 15 A max 8 7 A max 13 1 A max 0 4mA 15A resettable circuit breaker 5 ms typical Tel ISDN ADSL Ethernet 2x12V 7Ah Once a week 2x12V 9Ah 4 years typical depending on temperature and number of discharge cycles Oto 35 C 32 0 954
23. that the UPS be permanently connected to the AC power supply to ensure the best possible performance Switching on the UPS Press button 6 for about 1 second Surge protection outlets 49 without battery backup Equipment connected to these outlets is supplied as soon as the AC cord 6 is plugged in They are not affected by button 6 Battery backup outlets 49 Equipment connected to these outlets is supplied as soon as button turns green see figure E These outlets can be turned on even if the UPS is not connected to AC power button 6 flashes 8 614 06818 01 AC power disturbance e f AC power is disturbed or fails the UPS continues to operate on battery power Button 6 flashes green In normal mode the audible alarm beeps every ten seconds then every three seconds when the end of battery backup time is near In silent mode the audible alarm simply beeps once when the UPS transfers to battery power e f the power outage lasts longer than the battery backup time the UPS shuts down and automatically restarts when power is restored Following a complete discharge a few hours are required to recharge the battery back to full backup time Surge protection All outlets include surge protection Shutdown of the battery backup outlets 49 Press button 6 for more than two seconds 7 Troubleshooting ENGLISH For further information visit the www powerquality eaton com site or contact post sales support
24. www eaton com EATON 55 700 1000 1500 Installation and user manual English Fran ais Espa ol Portugu s Powering Business Worldwide Packaging E z a oO FEET SEE Bzz Caution EN e Before installing the Eaton 5S read the booklet 3 containing the safety instructions that must be followed Then follow the instructions given in this manual 4 FR e Avant l installation de Eaton 5S lire le livret 3 qui pr sente les consignes de s curit respecter Suivre ensuite les instructions du pr sent manuel 2 ES e Antes de la instalaci n del Eaton 5S leer el manual 3 que presenta las instrucciones de seguridad a cumplir A continuaci n seguir las instrucciones del presente manual 2 PT e Antes da instala o do Eaton 5S ler o caderno 3 onde constam as instru es de seguran a a respeitar Depois seguir as instru es do presente manual 2 Quick start 2 614 06818 01 1000 1500 Internet modem fax Service cable Register warranty at powerquality eaton com 614 06818 01 3 Battery disposal and safety e Caution Battery service life is reduced by 50 for every ten degrees above 25 C 77 F e The battery must be replaced exclusively by qualified personnel risk of shock with new battery approved by Eaton to ensure correct operation of the UPS e The battery must be disposed of in accordance wi