EM90 I-Red Thermometer with T-C Manual
Contents
1. Hold H icon will be displayed on the LCD Press the key once more to cancel the hold function 7 Auto power off setting The instrument is factory set for Auto Power Off The meter will power itself off after 25 seconds IR or 20 minutes thermocouple if no key is pressed To cancel the auto power off function press the LASER key whith power on until the LCD displays all icons and the back light is on Emissivity and Field of View Emissivity Emissivity is a term used to describe the energy emitting characteristics of a material The higher the emissivity value a material has the more infrared energy it will emit at a particular temperature Most organic materials range in emissivity between 0 85 and 0 98 This thermometer has a fixed non adjustable emissivity of 0 95 Measuring objects with an emissivity of less than 0 95 will result in a lower than actual temperature reading on the display Be aware of this characteristic when measuring low emissivity objects e g shiny reflective metal objects An effective solution is that using the black adhesive tape to cover the object surface taking the measurement when the adhesive tape s temperature is the same as the object Field of View The distance to spot ratio for this thermometer is 2 1 The ideal working range of the noncontact thermometer is between 25mm 10 250mm 1 and 10 inches The field of view is a circular measurement area approximate
2. LR E3 1 D Symbol Designations 1 Indicates Data Hold Indicates the type of thermocouple Indicates IR measurement Emissivity Measurement Display area Measurement Display area Average Maximum minimum Indicator Indicates laser pointer use Indication back light ON oO Oc N Oo oO A W N 10 Temperature units 11 Low battery indicator Operating instructions 1 Press the ONDE key to turn the unit on Press the key again to shift the measurement mode between infrared or thermocouple 2 While in Infra red mode press the LASER key to make IR measurements Point the laser at the target Eirg object and press the SCAN H key for continuous temperature measurements 3 In the thermocouple mode press the SCAN H key for data hold Press the SCAN H key again to return the measurement mode Function Keys 1 TYPE ON OFF Key ON OFF Press this key to turn the power ON and press the key again for more than 2 seconds to turn the power OFF TYPE Press this key to select infra red thermocouple mode M l Lo 2 50 key Turns back light on or off 2 UNIT key Press this key to select temperature units F or C 3 MODE key Press this key to select AVG MAX or MIN mode 4 LASER key Turns the laser on off for IR measurements 5 SCAN H key While in infra red mode press this key to take measurements While in thermocouple mode Press this key for Data
3. Test Equipment 99 Washington Street Depot Melrose MA 02176 Phone 781 665 1400 1 800 517 8431 Toll Free 1 800 517 8431 EM90 INFRA RED THERMOMETER amp THERMOCOUPLE METER 129 o m Users Manual 1 B introduction Thank you for purchasing the SUPCO infrared IR thermometer and thermocouple meter Please take a few minutes to browse through this user manual before you begin to operate the meter to ensure that you are fully familiarized with how best to operate the meter as accurately and safely as possible This meter combines two precision thermometers in one unit a noncontact infra red thermometer and a thermocouple thermometer This meter can match standard type K type thermocouple sensor WARNING Do not point laser directly at eye or reflective surfaces 1 1 Precautions safety measures To get the best performance from this meter please read this user s manual carefully and observe the detailed safety precautions EI 1 1 1 During use 1 After abrupt ambient temperature changes allow instrument temperature to stabilize for 30 minutes before taking measurements 2 Do not expose thermometer to excessive ambient temperatures 3 Keep the thermometer clean 1 1 2 Maintaining the product Do not measure in a high temperature high humidity locations When not using the instrument for a long time please remove the battery and avoid storing in high temperature and high humidity Featur
4. es 1 Display 4 digit LCD Display 2 Resolution 0 17F 0 1 C 1 F 1 C thermocouple above 1000 C Be 3 Range Infra red 58 F to 572 F 50 C to 300 C Thermocouple 328 F to 2372 F 200 C to 1300 C 4 Accuracy Infra red 5 for 58 F to 4 F 50 C to 20 C 1 5 reading 4 F 2 C for 4 F to 572 F 20 C to 300 C Thermocouple 0 2 reading 2 I 1 C for 328 F to 148 F 200 C to 100 C 0 1 reading 0 7 C 1 4 F for 148 F to 2372 F 100 C to 1300 C Emissivity 0 95 Field of view 2 1 Laser power Less than 1 mw Response time 0 5 second Eni GUI Auto power off 25 seconds infrared or 20 minutes thermocouple 10 Low battery indicator 4 11 Operating environment 32 F to 122 F 0 C to 50 C 0 to 90 RH 12 Storage environment 14 F to 140 F 10 C to 60 C 0 to 80 RH 13 Dimensions 4 76 L x 2 36 W x 1 18 H 121mm L x 60mm W x 30mm H 14 Weight 6 35 oz app 180 g app 15 Accessories K type thermocouple wire 1 Lanyard 1 AAA Batteries 3 Users manual llinstrument Description 1 Sensor cover 2 Infra red sensor 3 Thermocouple jack 4 LCD display 5 Function key Infrared temperature thermocouple meter LCD Display 6 D E SCAN UAEM s AVG MAX MIN t ic 5 PE 0
5. ly equal to the distance from the target to the unit divided by 2 To ensure accurate measurements the measurement target must fill or exceed the field of view Maintenance 1 CLEANING INSTRUCTIONS The meter may be wiped down with a wet sponge or cloth using a mild water based detergent NOTE This unit is not designed for complete submersion or washing in water 2 BATTERY REPLACEMENT Use the following procedure When the battery voltage drops below proper operation range the symbol will appear on 11 the LCD display and the battery needs to be replaced co Press the battery cover towards the arrowhead to open the battery cover co Replace the battery with three new AAA 1 5V batteries co Replace the battery cover WARRANTY Sealed Unit Parts Co Inc warrants that it will repair or furnish without charge a similar product to replace any product which within the specified warranty term after the date of sale by the Wholesaler is proved to the satisfaction of Sealed Unit Parts Co Inc to have been defective at the time it was sold Said warranty is in effect only when said item is used in accordance with the instructions and recommendations of Sealed Unit Parts Co Inc NT This warranty applies only to products which after shipment from the factory have not been altered changed repaired or treated in any manner whatsoever This warranty to repair or replace is the
6. only warranty either expressed implied or statutory and is the only warranty being issued herein Sealed Unit Parts Co Inc s liability in connection with its products is expressly limited to the repair or replacement of defective parts All other damages and warranties statutory or otherwise are being expressly excluded No representative of Sealed Unit Parts Co Inc has authority to change this warranty in any manner whatsoever No attempt to repair or promise to repair or improve any part covered by this warranty by any representative of this company shall be effective unless signed by a properly authorized officer of Sealed Unit Parts Co Inc 13 14 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com
Download Pdf Manuals
Related Search
Related Contents
Invacare® Comet ブラシレスDCモータドライバ 取扱説明書 PG-LW2000 Operation-Manual DE Micro Innovations NBP76S User's Manual 取扱説明書 - ご家庭のお客さま/大阪ガス Installer/User Guide - CNET Content Solutions PDF 取扱説明書 HP e3000 User's Manual Manuel d`utilisation du DR340 F-BRVP 5IN1772_2-iConnect Full User Manual EN Copyright © All rights reserved.