Contents
1. 1 Press button Menu to enter manage menu when FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press to enter User interface As shown below Keyking FPC2000 Add Delete Modify Add Admin Delete AII 3 Press 5 to enter Delete All interface Page 18 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Delete all Y 1 N 2 4 Press the corresponding number to select press Enter to confirm deleting 3 2 Network Configuration 3 2 1 Terminal ID 1 Press button Menu to enter manage menu FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 1 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press 2 to enter Network interface As shown below Keyking FPC2000 Terminal ID Net Configure IP Address Subnet Mask Gateway Host IP Host Port 3 Press 1 to enter Terminal ID interface km stands for delete button en en stands for symbolic button Keyking FPC2000 Terminal ID 0001 4 Input the Terminal ID by using the keypad and press Enter to confirm Page 19 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd 3 2 2 Net Configure 1 Press button Menu to enter manage menu FPC2000 is idle In the foll
2. Black EE mm Figure 2 5 Magnetic Lock Fail safe Page 8 of 35 KEYKING KEYKING GROUP LIMITED FPC2000 Biometric Standalone User Manual V1 0 EE Figure 2 6 Cathode lock Fail secure 2 4 TCP IP Network FPC2000 TCP IP network HUB Figure 2 8 TCP IP crystal head Figure 2 2 Normal net cable to switch Page 9 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 URINE Br Br G B B G 0 0 Br Br G B B G 0 0 87654321 87654321 Figure 2 10 Crossed cable to PC Br Br G B B G 0 0 Br Br 0 B B O G G 87654321 87654321 Figure 2 11 Page 10 of 35 KEYKING KEYKING GROUP LIMITED FPC2000 Biometric Standalone User Manual V1 0 Chapter3 Instructions User Management PIN management Work mode and Time set are configured in the manage menu Menu structure is shown below ETE EEH me Ee EAN EUN GHEHE wan ce paz Imp Leen El Fen aE En mmm end OE en cn teer Gl Ge eee GEE Rec an C oO 0 s lock seemed Corien p E E ug Door Rear paa Wael Page 11 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd 3 1 Personnel Management 3 1 1 Add Personnel 1 Press button Menu to enter manage menu when FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User Network Option Device
3. Terminal Info 2 Press to enter User interface As shown below Keyking FPC2000 Add Delete Modify Add Admin Delete AII 3 Press 1 again to enter Add interface As shown below Keyking FPC2000 4 Input the new ID and press enter to the next interface As shown below Keyking FPC2000 FP FP Card FP CARD UserID FP User ID card 3 1 1 1 FP 1 Press 1 to enter Add FP interface As shown below Page 12 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Level 1 1 0 9 0 2 Select a level according to customer s requirement High level for high matching accuracy but will low down responding time press Enter to enter the next interface Keyking FPC2000 Enable 1 N N 0 Y 1 3 Press 0 to confirm that the FP is attached to the User ID else press 1 stands for searching FP in the database Press Enter to enter the next interface Keyking FPC2000 Add FP Put Your FP 4 Put your finger right twice to finish registering The screen will display Add FP OK and then go back to the main menu 3 1 1 2 FP Card Enter the following interface referring 3 1 1 Keyking FPC2000 FP FP Card FP CARD UserID FP User D card 1 Press 2 to enter add FP Card interface As shown below Keyking FPC2000 Add card Place your card 2 Place the card in the sensor area system will enter the next interface after a beep so
4. Connect to PC first Device not power up FPC2000 Lock Can not open door by flashing card or FP Invalid card FP register your card FP Door open mode Set to Card or Card FP Invalid card register your card Invalid FP register your FP Can not open the door when it s Card FP mode Over interval time between flash card and verify FP No connected door bells Door bell not working Cable problem Faulty door bells Wrong Time Date e Set Time Date in manage menu Page 35 of 35
5. Each interface is shown below Keyking FPC2000 Keyking FPC2000 Keyking FPC2000 Relay Time Door Status Open too long time 00 30 O1 O NO 1 NC 0 00 30 20 Relay Time Relay activate time Door Status NO stands for Door normal open NC stands for door normal close Open toolong time Interval time to alarm if door remains opened 3 3 5 MultiFP Verify 1 Enter the following interface referring to 3 3 1 Page 26 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Language Clock Setting Screen Saver Door Relay MultiFP Verify Tamper Alarm 2 Press 5 to enter MultiFP Verify interface As shown below Keyking FPC2000 MultiFP Verify N 0 Y 1 1 3 Press O stands for not to enable Multi FP Verify while 1 stands for affirmative Press Enter to confirm 3 3 6 Tamper Alarm 1 Enter the following interface referring to 3 3 1 Keyking FPC2000 Language Clock Settings Screen Saver Door Relay MultiFP Verify Tamper Alarm 2 Press 6 to enter Tamper Alarm interface As shown below Keyking FPC2000 Tamper Alarm N 0 Y 1 1 3 Press 0 stands for not to enable Tamper Alarm while 1 stands for affirmative Press Enter to confirm Page 27 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd 3 4 Device 3 4 1 FP Module 1 Press button Menu to enter manage menu FPC2000 is idle In the follo
6. Option 4 Device 5 Terminal Info 2 Press 2 to enter Network interface As shown below Keyking FPC2000 Terminal ID Net Configure IP Address Subnet Mask Gateway Host IP Host Port 3 Press 6 to enter Host IP interface km stands for delete button m m stands for symbolic button Keyking FPC2000 Host IP 192 168 X X 4 Input the Host IP and press Enter to confirm 3 2 7 Host Port 1 Press button Menu to enter manage menu FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press 2 to enter Network interface As shown below Page 23 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Terminal ID Net Configure IP Address Subnet Mask Gateway Host IP Host Port 3 Press 7 to enter Host Port interface ET Stands for delete button m om stands for symbolic button Keyking FPC2000 Host Port 8000 4 Input the Host Port and press Enter to confirm 3 3 Option 3 3 1 Language 1 Press button Menu to enter manage menu FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press 3 to enter Option interface As shown below Keyking FPC2000 Language Clock Setting S
7. interface as shown Keyking FPC2000 Keyking FPC2000 WG Out Type 0 WG Out Mode 2 O Card O None ZUser ID 1 26bit 2 34bit WG Out Type Select the needed type by pressing the corresponding keys WG Out Mode Select the needed type by pressing the corresponding keys 3 4 3 Card Number Mode 1 Enter the following interface referring to 3 4 1 Page 29 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 FP Module WG Setting Card Number Mode Display Mode Terminal Init 2 Press 3 to enter Card Number Mode interface As shown below Keyking FPC2000 Card Number Mode 2 0 Dec Hex 2 Wiegand 3 Card number is displayed on the screen Press Enter to confirm your choice after finishing selecting Card Number Mode 3 4 4 Display Mode 1 Enter the following interface referring to 3 4 1 Keyking FPC2000 FP Module WG Setting Card Number Mode Display Mode Terminal Init 2 Press 4 to enter Display Mode interface As shown below Keyking FPC2000 Display Mode 3 None User ID UserName UserName UserID CardNo CardNo UserID CardNo UserName CardNo Name User ID 0 l 2 3 4 5 6 7 3 There are 5 options can be choose from input the corresponding letter and press Enter to confirm Page 30 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd 3 4 5 Terminal Initialize 1 Enter the follow
8. no longer needed employees can enter their special space by flashing authorized cards FPC2000 can by itself control a door both in and out at least one reader is needed for one side and the other side can be controlled either by a reader or a Rex Button This system provides a more convenient and secured access environment it also makes it possible for managers to verify the attendance in time FPC2000 is compatible with a big range of applications including building management enterprise management government military and prison enen EIE FPC2000 FPC2000 Appearance FPC2000 Diagram Model Definition FPC2000 E Built in EM Card Reader FPC2000 H Built in HID Card Reader FPC2000 U Built in Mifare CPU Card Reader Supported Card Type E EM Card Exp EM4100 TK4100 Series Page 3 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd H HID Card Exp 1326 1386 Series U FM1208 CPU Card Philips S50 Mifare 1 Compatible 1 2 Features TFT color display with elegant appearance Standard Wiegand 26 34 output compatible with Wiegand format access controller Dust and water resistant suitable for wide kinds of installations Quick responding anti interference low power consumption and stable WDT circuit self checking function High speed of fingerprint matching 3000 fingerprints within 1 second Multithreaded code has taken full advantage of multi core CPU
9. reader of FPC2000 if verify passed the screen will show that verify OK and display User ID User Name and Card Number Then the replay will response door open If verify failed then FPC2000 will beep three sounds and display Please try again door remains closed Note Only the registered personnel can pass verifying 2 FP Card Application Flash a registered card or FP FPC2000 can control a door by FP Card 3 FP4Card Application Flash a registered card and FP Flash a registered card in front of FPC2000 read range 3 10cm FPC2000 will beep a long sound and then put your finger on the reader if verify passed then door will open The interval time between flashing card and verify FP is 8 seconds 4 _UserlD FP or UserlD Card Application Input your User ID by using the keypad and then verify your FP or flash your card to complete access process Page 32 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 D Chapter 4 Installation 4 1 In the Wall 1 Use installation box Drill a hole on the wall size 86x86mm where you want to install your reader Then install the installation box in the hole Installation box Standard 86 box single Wiring Design the wiring between reader and controller then process wiring Connection Please refer to chapter 2 of the connections Fix base plate Use a M4 30 screw to fix the bottom of the base plate on the installation box Two o 6 deep 40mm holes should
10. screen will display Add FP OK and then go back to the main menu 3 1 1 4 UserID FP Enter the following interface referring 3 1 1 Keyking FPC2000 FP FP Card FP CARD UserID FP User D card 1 Press 4 to enter add UserID FP interface As shown below Keyking FPC2000 Level 1 1 0 9 0 2 Select a level according to customer s requirement High level for high matching accuracy but will low down responding time press Enter to enter the next interface Keyking FPC2000 Add FP Put your FP 3 Put your finger right twice to finish registering The screen will display Add FP OK and then go back to the main menu Page 15 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd 3 1 1 5 User ID card Enter the following interface referring 3 1 1 Keyking FPC2000 FP FP Card FP CARD UserID FP User ID card 1 Press 5 to enter add UserlD Card interface As shown below Keyking FPC2000 Add Card Place your card 2 Place the card in the sensor area system will enter the next interface after a beep sound 3 1 2 Delete Personnel 1 Press button Menu to enter manage menu when FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press 1 to enter User interface As shown below Keyking FPC2000 Add Delete Modify Add
11. tenen 309 eN ONCE aandere ee Onde A dennen Suo d DOE KOA nae 20220998 0002 Bodie MUl E E DIE oosuoscua aua koe doa ea EE TSRE SERE UR ICE P2P CA QEPUR 3 206 Tamper Alar aces ica Lini oa otra nde S MB Io ERROR ERU tae ttnahcatsdueteatensanatis ST IBPSIVEOONIIS oenn e 25 12 WOOS coo dead statl no Tad Uo EE Vin dac edere nend dinar 3 4 3 Card Number Mode esses 3 4 4 Display Mode risen eio rotes 3 4 5 Terminal Initialize eese 294 Terminal IWEO ercczsesecesceseassesessnsawcetaeatseateeoceseeeenseteosinsanenes 5 5 Door Open MOS cicrsinicassatascecentna cessebovisgnaipadinsatraaeanrinae Chapter 4 Installation azorssssssrrmegershnrddenerwaeserdhnsetentansdsahehndedandne SN ERST 4 2 Without Installation Box eeeeeeeeeeeeeneee CALS ANO T Uom Page 2 of 35 FPC2000 Biometric Standalone User Manual V1 0 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 s Chapter 1 Introduction 1 1 Summary FPC2000 is a new outstanding biometric standalone controller with TFT color display developed by KEYKING When FPC2000 works as T amp A controller employees need to press their finger on the reader which has to be authorized to complete attendance The TFT screen will display time and staff ID info This system greatly improved the T amp A simplicity and offered cost saving on traditional tags When FPC2000 works as an access controller the traditional key is
12. 500dpi optical biometric sensor scratch resistant World leading fingerprint algorithm resistant fake fingerprint Support Chinese English interface Background picture and company name can be changed base on customer s requirement Display card number user name employee ID and etc opecifications CPU 400MHz DSP Memory 4MB Flash memory 8MB RAM Fingerprint storage 3000 pcs Cexpandable to 8000 pcs Supported card E Proximity EM4100 series M S50 compatible Mifare card or other compatible cards Biometric sensor 500 dpi optical biometric sensor Verify mode FP Card Card FP ID FP Communication interfaces Wiegand output TCP IP communicate Working voltage 12VDC Working current lt 200mA Standby current 150mA Temperature 20 C to 65 C Humidity 0 95 Dimension 197mm L x88mm W x 35mm Weight 490 g 1 3 Application Mode 3 Application Modes Page 4 of 35 KEYKING KEYKING GROUP LIMITED FPC2000 Biometric Standalone User Manual V1 0 Standalone Outdoor external reader indoor FPC2000 Outdoor reader Indoor FPC2000 e Indoor external reader outdoor FPC2000 Outdoor Indoor FPC2000 Reader Page 5 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 EE Chapter2 Wiring Diagram 2 1 FPC2000 Appearance LED Blue amp Green Background picture Keypad Biometric Sensor Reader Sensor Area MUI Figure 2 1 LED e Blue
13. Admin Delete AII 3 Press2 to enter Delete interface Page 16 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 UserID DEL 4 Inputthe UserID which is to be deleted then press Enter to confirm 3 1 3 Modify Press button Menu to enter manage menu when FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press to enter User interface As shown below Keyking FPC2000 Add Delete Modify Add Admin Delete AII 3 Press3 to enter Modify interface Keyking FPC2000 Input UserID MOD 4 Input the UserID which is to be modified customer can change configuration like level 1 1 or replace FP or card 3 1 4 Add Admin 1 Press button Menu to enter manage menu when FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Page 17 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press to enter User interface As shown below Keyking FPC2000 Add Delete Modify Add Admin Delete AII 3 Press 4 to enter Add Admin interface Keyking FPC2000 Admin ID NEW 4 Input new Admin ID and press Enter to the next interface Refer to 3 1 1 3 1 5 Delete All
14. LED Power indicator e Green LED Sensor indicator Relay on indicator Keypad Numeral 5 Key Door bell Em 0 es s Nimes 16 Bue EmerContim Page 6 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd 2 2 Wiring Diagram J1 contact Switch Power Door J3 Reader signal output input inputs J2 Relay Output naon inpuvouipui et He mi EN Relay output Figure 2 1 Wiring Description J1 Power supply Magnetic door contact Rex Button Auxiliary input v 2V DC 12V Positive GND Ground SEN Door contact BUT Rex Button GND Ground INI Auxiliary input NN SN S S Page 7 of 35 KEYKING KEYKING GROUP LIMITED FPC2000 Biometric Standalone User Manual V1 0 EE J2 Relay output v Based on customized lock model and power requirement J3 Reader signal input output v DI Out Wiegand signal output DO Out Wiegand signal output 12V DC 12V Positive GND Ground D1_In Wiegand signal input YAS S v DO In Wiegand signal input J4 TCP IP interface v Customer can set all configurations when it s connected to host PC Moreover user authorization and exporting card events can also be done via manage software v To use a switch or directly connect to host PC via Ethernet port 2 3 Lock Wiring Diagram J4 Relay Output Lock Control As shown below a ezac POOSLDElectranie lock D
15. User Manual Thank you for purchasing Keyking products Please read this manual thoroughly before using FPC2000 Biometric Standalone KEYKING KEYKING GROUP LIMITED KEYKING KEYKING GROUPLIMITED Chapter 1 Inttoductiob siisazciosatennsoccusasaeaadansdancenactanatensionraens B eI ISP SUPPE omm 1 3 Application MOIS zssereoirderingirdcasotds deti pi Ure i ird R Chapter2 Wiring Diagram eeeeeseseeseeeeeeeeeeeee nnn 2 1 FPC2000 APC aranCe nerersaarsnorsvereneronsrenneserenorsorsreaedesen 2 2 Witte DISSratWltonoicei quii or oio dad Eo Roo E09 TCI EE ERE GRRR ORA 2 3 Lock Wiring Diagram eeessssseeeeeeeeeeeeennn 24 TCE INCI OMe s aputiouden edd inbicu eu acus iub ru NIU Chapter Instructions uideret itur tussi esauc teo d 60d dod tad ramos criin 3 1 Personnel Management naaar 3 1 L Add Pers OB ol er RIG Oe Re mucosa Sale 2 Deler Peronin epep reann 20220995 2222 le MO I SNR ESTE CHR ae SU Me DAL EO 3 2 Network ConfiguratiOn nan nnnnnneneren eeens nenevens 22 dT OEIL UD oco eotaiseo rore oo EHE PP EISE P EHE ERU SUP POEUE 3 2 2 INCE COMIC NEG i diiit Ep ERE GURL IP EUR ae SLE v dI ORA FP Heo Wag C88 coh ee mene eee eee em et nn mn mene 902 d SU ONG LIVITS Ke saccnsadoasaniacasaamsdataentncosanoiadossaniacassaens Beds OW AY nonsens p 2 Om OSU IP E TEA T E T T T S VN POPO e E E SR EVI E Sok EAS T n 929 2 CTOCK SCD ooomuiccae initio USA Ro ME EUCUP
16. be drilled on the upper side then slide two rubber plugs into the holes and fix the base plate with two 4mm 30mm screws 5 The upper side of the FPC2000 should be fixed on the base plate first then make the reader in vertical position and use a M3 4 screws to fix it Page 33 of 35 KEYKING KEYKING GROUP LIMITED FPC2000 Biometric Standalone User Manual V1 0 EE 4 2 Without Installation Box pe coc um Cut a square hole in the wall Width 70mm Height 60mm Wiring Design the wiring between reader and controller then process wiring Connection Please refer to chapter 2 of the connections Fix base plate First drill 3 6 deep 40mm holes and put rubber plugs in then make the reader in vertical position and use a M3 4 screws to fix it If the reader is to install on metal frame then please make sure the frame width Is above 90mm next cut a square hole in the wall Width 70mm Height 60mm drill 3 6 deep 40mm holes and tap them with M4 screw tap Finally make the reader in vertical position and use a M3 4 screws to fix it Page 34 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Chapter 5 FAQ Descriptions No response for flashing indicator off buzzer Power problem check power supply no beeping Invalid card type use supported card Set short relay responding time in manage Door stays opened menu s FP or card information missing Register FP Card in PC
17. creen Saver Door Relay MultiFP Verify Tamper Alarm 3 Press 1 to enter Language interface As shown below Page 24 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Language O EN 1 CHN 1 4 Press the corresponding number O English 1 Chinese and press Enter to confirm 3 3 2 Clock Setting 1 Enter the following interface referring to 3 3 1 Keyking FPC2000 Language Clock Setting Screen Saver Door Relay MultiFP Verify Tamper Alarm 2 Press 2 to enter Clock Setting interface As shown below Keyking FPC2000 Clock Setting 20130815095430 3 Input the accurate time and press Enter to confirm 3 3 3 Screensaver 1 Enter the following interface referring to 3 3 1 Keyking FPC2000 Language Clock Setting Screen Saver Door Relay MultiFP Verify Tamper Alarm 2 Press 3 to enter Screensaver interface As shown below Page 25 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Screensaver SEC 010 3 Input the interval time and press Enter to confirm 3 3 4 Door Relay 1 Enter the following interface referring to 3 3 1 Keyking FPC2000 Language Clock Setting Screen Saver Door Relay MultiFP Verify Tamper Alarm 2 Press 4 to enter Screensaver interface As shown below Keyking FPC2000 1 Relay Time 2 Door Status 3 Open too long time 3
18. ing interface referring to 3 4 1 Keyking FPC2000 FP Module WG Setting Card Number Mode Display Mode Terminal Init 2 Press 5 to enter Display Mode interface As shown below Keyking FPC2000 1 Init Parameter 2 Delete All Log 3 Initial Terminal 3 Press the corresponding key to enter each interface as shown Keyking FPC2000 Keyking FPC2000 Keyking FPC2000 Init Config Delete All Log Initial Terminal 1 Y 2 N 1 Y 2 N 1 Y 2 N Init Parameter Initialize all parameters Delete All Log Delete all personnel data FP and attendance Log Initial Terminal Set terminal to defaulted status Note Initial Terminal will clear all data in the device please take a thorough consideration before operating 3 4 Terminal Info 1 Press button Menu to enter manage menu FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 1 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press 5 to enter Terminal Info interface As shown below Page 31 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Device ID 0001 Version 1 00 Language English MAC 00 10 F0 00 43 1D IP 192 168 4 207 The screen will show the basic information of the device such as Device ID Version Language Mac Address and IP Address 3 5 Door Open Mode 1 FP Mode Application Put your finger on the biometric
19. nfirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press2 to enter Network interface As shown below Keyking FPC2000 Terminal ID Net Configure IP Address Subnet Mask Gateway Host IP Host Port 3 Press 4 to enter Subnet Mask interface Km stands for delete button en en Page 21 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd stands for symbolic button Keyking FPC2000 Subnet Mask 255 255 x x 4 Input your Subnet Mask and press Enter to confirm 3 2 5 Gateway l Press button Menu to enter manage menu FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press 2 to enter Network interface As shown below Keyking FPC2000 Terminal ID Net Configure IP Address Subnet Mask Gateway Host IP Host Port 3 Press 5 to enter Gateway interface Km stands for delete button en en stands for symbolic button Keyking FPC2000 Gateway 192 168 X X 4 Input your Gateway and press Enter to confirm 3 2 6 Host IP l Press button Menu to enter manage menu FPC2000 is idle In the following Page 22 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3
20. owing steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press2 to enter Network interface As shown below Keyking FPC2000 Terminal ID Net Configure IP Address Subnet Mask Gateway Host IP Host Port 3 Press 2 to enter Net Configuration interface k m stands for delete button emm stands for symbolic button Keyking FPC2000 Net Configure 0 O Writable Protected 2 Forced IP 4 Select a configuration and input the corresponding number then press Enter to confirm 3 2 3 IPAddress Press button Menu to enter manage menu FPC2000 is idle In the following steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info Page 20 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd 2 Press 2 to enter Network interface As shown below Keyking FPC2000 Terminal ID Net Configure IP Address Subnet Mask Gateway Host IP Host Port 3 Press 3 to enter IP Address interface Km stands for delete button En en stands for symbolic button Keyking FPC2000 IP Address 192 168 x x 4 Input the IP address and press Enter to confirm 3 2 4 Subnet Mask 1 Press button Menu to enter manage menu FPC2000 is idle In the following steps Esc works as cancel while Enter works as co
21. und Page 13 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Level 1 1 0 9 0 3 Select a level according to customer s requirement High level for high matching accuracy but will low down responding time press Enter to enter the next interface Keyking FPC2000 Enable 1 N N 0 Y 1 4 Press 0 to confirm that the FP is attached to the User ID else press 1 stands for searching FP in the database Press Enter to enter the next interface Keyking FPC2000 Add FP Put your FP 5 Put your finger right twice to finish registering The screen will display Add FP OK and then go back to the main menu 3 1 1 3 FP Card Enter the following interface referring 3 1 1 Keyking FPC2000 FP FP Card FP CARD UserID FP User D card 1 Press 3 to enter add FP Card interface As shown below Keyking FPC2000 Add Card Place your card 2 Place the card in the sensor area system will enter the next interface after a beep sound Page 14 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd Keyking FPC2000 Level 1 1 0 9 0 3 Select a level according to customer s requirement High level for high matching accuracy but will low down responding time press Enter to enter the next interface Keyking FPC2000 Add FP Put your FP 4 Put your finger right twice to finish registering The
22. wing steps Esc works as cancel while Enter works as confirm Keyking FPC2000 User 2 Network 3 Option 4 Device 5 Terminal Info 2 Press 4 to enter Device interface As shown below Keyking FPC2000 FP Module WG Setting Card Number Mode Display Mode Terminal Init 3 Press 1 to enter FP Module interface As shown below Keyking FPC2000 Level 1 1 Level 1 N I Capture Auto Detect 4 Press the corresponding letter to enter each interface as shown Keyking FPC2000 Keyking FPC2000 Level 1 1 Level 1 N 1 9 4 3 9 5 Keyking FPC2000 Keyking FPC2000 I Capture Auto Detect N 0 Y 1 1 N 0 Y 1 1 Level 1 1 Verify FP with all the registered FP high level for high matching accuracy Page 28 of 35 KEYKING KEYKING GROUPLIMITED FPC2000 Biometric Standalone User Manual V1 0 hd but will low down responding time Level I N Verify FP with all FP in the database high level for high matching accuracy but will low down responding time I Capture Press 1 to enable I Capture O to disable I Capture Auto Detect Press 1 to enable I Capture 0 to disable I Capture 3 4 2 WG Setting Enter the following interface referring to 3 4 1 Keyking FPC2000 FP Module WG Setting Card Number Mode Display Mode Terminal Init 2 Press 2 to enter WG Setting interface As shown below Keyking FPC2000 1 WG Out Type 2 WG Out Mode 3 Press the corresponding key to enter each
Download Pdf Manuals
Related Search
Related Contents
Click - Semillas ABE 灯具ユニッ ト (一般屋内用) L`ENCADREMENT DES LOYERS ET LE CONTRAT TYPE König SAS-DVRODR10 surveillance camera 39991 BLH 500 3D troubleshooting.indb RIVER LIGHT JAPAN LCD-26XR7 LCD-32XR7 SERVICE MANUAL LCD TV Samsung PL210 aparat kompaktowy Instrukcja obsługi Copyright © All rights reserved.