Home
Zyla Quick Start Guide
Contents
1. E slots ONLY a screw 4 Unused filler brackets If you are unsure which slot is correct please consult the PC user manual T Gently press the card into the slot 4 Remove the filler bracket corresponding to the slot you intend to use 5 Remove the controller card carefully from its protective ESD packaging and CLI insert the card connector fully into the expansion slot 6 Ensure the card s mounting bracket is flush with any other mounting or filler brackets to either side of it then secure the controller card in place 7 Replace the computer cover and secure with mounting screws if applicable lt ISA Slot CL2 8 Reconnect any accessories you were using previously Karbon PCle card only NOTES e Zyla 10 tap can not be run in 3 tap mode e Do not connect any other device to the Framegrabber PCle card as this may interfere with normal camera operation or performance e Camera operation with PCle cards not supplied by Andor cannot be guaranteed Installing the PCI Card Device Driver Restart your PC If you are running Windows 7 or 8 the drivers will be installed automatically during start up EE Windows 8 and NOTE In Windows 7 and 8 allowing the computer to enter sleep mode will cause the Camera By Link card to hang after wakeup If this happens the software will no longer be able to connect amp Windows to the camera and a reboot will be required to reset the PCle card Users shoul
2. d deactivate sleep mode functions of the PC where possible refer to Windows 7 or 8 help on your PC Paw denice If you are running Windows Vista you may be asked to specify the directory containing the NINGOWS V S Bitflow drivers These are located in C Bitflow SDK 5 60 PlugAndPlay If you are running Windows XP the Found New Hardware Wizard dialog will be displayed A Win dows following boot up When prompted Can Windows connect to Windows Update to search for software select No and click on Next Select Install the software automatically option and click on Install The Camera drivers will now be installed If you are running Linux please refer to the SDK CD Any distribution specific differences will be noted in the installation instructions Further support is available at TE andor com support Connecting your Camera and Switching it on Ensure that the Camera ON OFF switch is in the OFF position AND your PC is switched OFF e For Water Cooled models ensure the coolant system is connected before the camera is switched on please refer to the user manual e Insert the 12V DC power cable into the power connector at the rear of the camera ensure the orientation is correct NEVER forcibly insert the connector Zyla 3 and 10 tap version Connections e For Zyla 3 and 10 tap versions insert Camera Link Cable CL1 connector labelled CL1 CAM into camera connector CL1 e Insert
3. dick Start Guide Camera Link Models ANDOR company o Unpacking your Camera and Accessories Zyla sCMOS Camera Software or Driver PCle Card Country Specific Camera Link Cable s Camera Link version CD and User Zyla 3 tap version Power Cord Zyla 3 tap version x1 Zyla 5 5 3 tap or 10 tap Manual on CD Neon PCle Card Zyla 10 tap version x2 Zyla 4 2 10 tap oi Zyla 10 tap version Karbon PCle Card SY Q s Q Si Anti Static Strap PS 12 Power Multi I O Coolant Pipes Supply Timing Cable Water cooled models only W Preparing your Facility amp y Installing Software Solis SDK3 or iQ Ee eee eee eae eee You must have administrator access on your PC to perform this installation Zyla SCMOS weighs 1 0 kg 2 Ib 2 oz Use correct power supply and cables The same instructions cover the installation procedure for Andor s Solis SDK or iQ software which is used in conjunction with third party software If you are planning to run your camera through a third party interface you will gt gt Observe anti static precautions when Store between 10 C and 50 C require the Andor Drivers called SDK3 installing the controller card and camera Zyla 5 5 all models Zyla 4 2 water cooled l l l l PR Gal ae Bal Switch on the PC insert CD and run the setup exe file on the CD or download location Ensure 100 mm clearance around camera Aln i oo e OPETE DEAR O Aa EISION Or SO and po
4. ly Control Panel System Hardware Device Manager Imaging Devices For additional troubleshooting information please refer to the user manual on the CD provided and for technical information about the Zyla sCMOS go to andor com zyla MAN 06734 ZQSG 0915 R1
5. the other end of the cable labelled CL1 PC into PCle card CLI connector CL1 I O 15 Way Gonner D Type e For Zyla 10 tap version only also insert Camera Link Cable Connector ae CL2 connectors labelled CL2 CAM and CL 2 PC into the CL2 AORE IN connectors of the camera and PCle card respectively 12V DC 10 tap only Please refer to diagrams in both Steps 4 and 6 to identify the Power locations of the CL1 and CL2 connectors PORDEGON e f required connect the I O expander cable to the I O 15 way D type ON OFF connector Switch e Switch the camera ON using the ON OFF switch You should hear an audible confirmation a short beep followed by a long beep e Turn ON the PC e Start your software e Start acquiring data NOTES e f you need to adjust the C mount refer to the Zyla user manual AN Troubleshooting Camera buzzer does not sound on start up e The camera buzzer should be audible momentarily as a short beep followed by a long beep when the camera is switched to ON e lf this does not occur ensure that power is connected to the camera and the ON OFF switch is set to ON Camera is not recognized by PC e Ensure camera is switched to ON The camera must be powered up before the software is initiated e Check that the camera cable s are securely and correctly connected between the camera head and the PCle card in the PC shown in step 6 e Check that the PCle card and drivers have been installed proper
6. wer supply vents Do not block e Follow the on screen prompts Setup Andor SOLIS er vents when operating on benchtop l l l een eee P g p For water cooled models the coolant system e Select the installation directory when prompted a a VI Operation of the camera close to intense Wie Beil and n poa e When prompted for camera type select Zyla es ee pulsed sources e g plasma and X ray set above the dew point before the camera l l i l l sources may compromise performance is switched on Refer to the dew point e On the final window click on Install During the installation Zya information in the user manual before use a number of other windows will appear as various drivers are Newton Models DUSK DVER installed Use tar Models DHT Keep dry lt 70 humidity non condensing e Click on the finish button when prompted Refer to the user manual for further information For more information visit andor com software software_support ee Please turn over A lt gt Installing the Camera Framegrabber PCle Card Ensure your PC is powered off Ensure anti static precautions using anti static strap provided Keep all screws safe 1 Unplug all cables from the rear of the computer 2 Open the PC enclosure to gain access to the expansion slots 3 Locate a suitable PCle slot e Zyla 5 5 3 tap with Neon PCle card use x16 x8 or x4 PCle slots e Zyla 5 5 and Zyla 4 2 10 tap with Karbon PCle card use x16 or x8 PCle