1. horn is identified by a single groove in the horn body and the large aperture at the end of the horn Signals wider than 30 can be detected but their intensity is reduced Their source is easily identifiable by the audio feedback the user has 3 horn For very accurate location of the leak source the 3 horn can be used This gives a very narrow beam of acceptance of signal and thus pin points the source of the leak It is not a good idea to start general leak surveys with this horn attached The 3 horn is identified by two grooves in the horn body and a small aperture at the end of the horn Bending horn The bending horn is for detecting leaks in difficult to access places such as boxed in pipework or in clusters of pipes The flexible pipe allows it to be threaded into hard to gain locations and essentially allows the detector to listen around corners Spare parts If any items are damaged or lost then they can be obtained separately from your agent A list of parts and their part numbers is included below P311 010 010 30 horn P311 010 020 3 horn P311 010 030 Bending horn P311 050 100 Battery charger P311 050 200 Earphones J311 ULTRASCAN LeakDetector UserManual 1 01 doc Designed and manufactured in the UK by E2L Limited Copyright 2004 Right to change product specifications reserved www ed2l uk com
2. User Manual for ULTRASCAN High Pressure Leak and Corona Discharge ector A manual for users of the E2L ULTRASCAN High Pressure Leak Detector Its operation deployment and maintenance Release 1 01 J311 ULTRASCAN LeakDetector UserManual 1 01 doc Contents Principle Introduction Equipment Identification Using the ULTRASCAN Leak Detector Power Down Time What mode am in How do I change the auto switch off mode Leak Detection Battery Low Battery Charging Focussing attachments 30 horn 3 horn Bending horn Spare parts J311 ULTRASCAN LeakDetector UserManual 1 01 doc ULTRASCAN High Pressure Leak Detector This manual provides necessary operating instructions for successful remote detection and location of leaks in high pressure systems such as compressed air steam pipe and hydraulic systems The unit can also be used to monitor medium to high voltage plant for partial corona or plasma discharge indicating insulator or contactor breakdown Principle All systems with gas under pressure such as compressed air will have some element of leakage As the gas escapes the localised changes in pressure produce considerable levels of high frequency noise Similarly electrical discharge also emits high frequency noise This noise is usually inaudible since it both too high for human perception and the surrounding environment is too noisy to distinguish the sound By using an ultrasonic micropho
3. ion that may help If you have any questions or any advice on improving both the ULTRASCAN and this manual please contact your agent Equipment Identification The ULTRASCAN case contains all the equipment you will need to conduct an investigation The case is shower proof but water should be avoided Similarly do not place the case on any high temperature surfaces Battery charger Leak Detector Focussing Attachments Earphones J311 ULTRASCAN LeakDetector UserManual 1 01 doc Using the ULTRASCAN Leak Detector The unit is designed to be as simple as possible whilst providing the highest performance There are only four controls on the instrument Auto range Volume UP Volume DOWN ON OFF There are two modes of operation Setting the Power Down Time and normal Leak Detection Power Down Time Power down time is the time before the unit automatically switches off if the user forgets to manually press the ON OFF switch You will probably only set this feature once The purpose of setting the power down time is to ensure the maximum battery life but also to match the user s requirements For example if you are using the device as a safety indicator then you would probably want the unit to always be on The unit can be set to auto switch off after 1 minute 5 minutes 15 minutes or never The unit can always be switched off manually What mode am in When the unit is initially switched on a se
4. ne the surrounding environmental noise is quieter and it is much easier to discern the signal coming from a gas leak By demodulating the ultrasonic noise we can make the signal audible to the human ear Consequently a leak sounds like a rush of air just as you would expect but without all the other audible surrounding noises included The same principle applies to vacuum systems and corona or plasma discharge By effectively detecting leaks results in 1 The cost of generating the compressed air vacuum or steam can be optimised not wasted 2 The workplace becomes safer J311 ULTRASCAN LeakDetector UserManual 1 01 doc Introduction Welcome to your ULTRASCAN leak detector We have made the ULTRASCAN simple to use but please read this manual to familiarise yourself with all of the operations and especially the safety instructions ULTRASCAN is a rechargeable battery powered portable unit intended for investigative tests lasting up to 18 hours As with any machine the care that you give it will reflect on its operational life and reliability Please take note of any safety and care instructions in this manual Because of the sophisticated design of the ULTRASCAN none of the internal parts are user serviceable Only have your instrument serviced or repaired by a approved E2L agent who has access to the correct equipment and spares In each section we guide you through the investigation process with examples plus other informat
5. quence of flashing lights indicates the auto switch off mode The different lights have the following meaning 15 minutes No auto switch off 5 minutes 1 minute J311 ULTRASCAN LeakDetector UserManual 1 01 doc How do I change the auto switch off mode To change the mode to a different timeout press and hold the ON OFF button The unit will then indicate its current mode and then illuminate each light in isolation When the correct timeout is reached release the ON OFF button and the unit will store this mode for future use After the button is released the mode is displayed again as if the unit has been powered up Leak Discharge Detection Connect the earphones and a suitable focussing attachment if required Power on the unit by pressing the ON OFF switch a The unit will initialise and indicate which auto switch off mode it is in Auto range Volume DOWN Point the unit away from the main area of investigation and press the Auto range button Volume UP The green light will flash several times until the unit has auto ranged When auto range is ON OFF complete all the lights will flash once Adjust the volume in the headphones to suit your own hearing preference Setup is now complete and leaks can be identified by pointing the focus tube in the direction of equipment under test Range will vary according to size and pressure of leak A leak is indicated by flickering of the red lights
6. similar to volume on a HI FI system and is clearly audible in the earphones If entering another area with a different level of ambient noise repeat Point the unit away from the main area of investigation and press the Auto range button The green light will flash several times until the unit has auto ranged When auto range is complete all the lights will flash once Battery Low If the green light starts to flicker quickly during normal operation the battery is beginning to run low and will need recharging Operation is unaffected for a considerable time whilst this condition exists Battery Charging Using the supplied battery charger plug it into the socket at the base of the unit and then connect to your mains supply The green light indicates the charging status and is always less bright in charging mode than in normal operation Flashing green light Trickle charging Constant green light Fast charge No light Charging complete J311 ULTRASCAN LeakDetector UserManual 1 01 doc Focussing attachments ULTRASCAN Leak Detectors come with three different focussing attachments horns that assist in identifying the source of a leak They are changed by means of a simple screw connection The unit can be used without any focussing attachments for very general or safety purposes 30 horn The normal mode of operation is to use the 30 horn This allows general area coverage in order to perform wide area scans The 30

Download Pdf Manuals

image

Related Search

Related Contents

Shure PSM 400 User Guide  ZyXEL Communications 2 Network Card User Manual  BISTRÔ - Balaroti  Installation and Service Manual  VC 40 / VC 20  Manual del usuario Probador Digital de aislamiento para alto voltaje  Developing your STM32VLDISCOVERY application using the Atollic  herbotisa herbotisa herbotisa herbotisa  取り扱い説明書  カタログ (PDF)  