Home

"user manual"

image

Contents

1. os3 2 000 oso 170 0003 12 03 24 oosss 033 2 000 o3oo 170 _ 0004 12 04 11 ooges 022 2000 0300 1700 _ G W 8 000 kg N W 6 800 kg Daily report 2 Date 2008 01 01 kg Daily report 3 Date 2008 01 01 0002 0002 3 400 Appendix 3 Micro printer format Applicable for printer type 5 Folding format S N 0001 DATE 02 03 14 TIME 10 57 27 T No 00001 C No 001 G W 10 00kg TARE 1 OOkg N W 9 0Okg tel 12345678 26 Record format DATE 02 03 14 S N weight kg 0001 9 00 0002 9 00 TOTAL 18 OOkg Appendix 4 Printing operation examples I One time manually pre set TARE printing weighing bill tm Te a Press input Minus TARE weight a __ Press print Original truck No Input truck No E g 00123 o 00123 If needs original truck No press input directly no Iaa to change 6 Press input hn _ _ Originalcargo No Input cargo No E g 11 hn 011 If needs a cargo No press input directly no pi e to euanee 8 Pressfinput Prnt Printweighing bill ll One time manually print cargo weighing bill directly Display 1 Goods on Press print o Original truck No platform melenIne object is cargo 3 Press input hn __ Original cargo No Input cargo No E g 11 hn 011 If needs PEE cargo No eer BEES to aange 5 Press input Prnt Print weighing bill III FE weighing bill twice weighi
2. Second frame mark bit is O G15 G8 Weight N W data Third frame mark bit is 1 G7 GO Weight data GO G18 19 digits ACII code of weight N W consist by the digits from low to high V Connection between Serial communication interface and indicator A communication interface output line should connect with computer correctly if there is any mistake on that it will damage indicator output interface or computer communication input interface or even damage indicator and computer and its external devices A For computer communication it requires knowing computer technology and programming ability Unprofessional people please don t connect it at your will XK3190 A9 has RS232 RS422 optional RS485 optional serial communication interface can communicate with computer 1 Communication interface adopts 15 core RS232 socket share with scoreboard its definition of foot is shown in Graph 2 5 foot 6 7 8 RS232 or foot 1 2 3 4 8 RS422 RS485 2 All data is of ASCII every unit of data consist of 10 bytes first bit is start bit 10 bit is stop bit 8 bit in the middle is data bit communication method divided as follow 1 Continuous method Tf 0 The sending data is the current weight G W or N W each frame of data consist of 12 unit of data Format as follow 3s Weighing data high bit Weighingdata e Weighingdata e 8 _ Weighingdata lowbit 9 DecimalNo fromrighttoleft O 4 12 03 XOFF en
3. tare directly no need of inputting truck No EEN 29 YM R YM tare ss Printing weighing bill one time stored Loaded truck is press print Orn Original truck No on platform wait for stable light is on Input new truck E g 00123 o 00123 If original truck No is No needed press input no need of input new truck No 3 _ press input Original cargo No Input new cargo 11 hn 011 If original cargo No is No needed press input no need of input new cargo No 5 press finput Prnt _ Printing weighing bill VIII Daily repot printing triplicate 2 Press IP O I Note 6 the date of printed daily report is current date of indicator press date to check and modify IX General report printing display 1 Press printset P00 Press 2 P 02 02 print general report 1 03 print general report 2 04 print general report 3 05 print general report 4 3 press input Print out general report 30
4. I ste form Press 5 8 8 6 High 4 bits of Tel setting Press Input E g 5886 Press 0 0 0 3 Low 4 bits of Tel setting Press Input E g 0003 End of operation 1 when you use A9 P s built printer the parameter of Printer type must be selected 5 to ensure the normal work 2 Step 8 and 9 only valid for Printer model 2 3 4 invalid for other model 3 Tel No only can print out when built in printer is applied and it is printed at bottom of the weighing bill Therefore step 11 12 13 is only for printer model is 5 these steps will be invalid when you select other models 1 Tel numbers are 7 digits then tH input 3 digits and tl input 4 digits 2 Tel numbers are 3 digits then tl input 3 digits step 12 will be Skipped G Tel numbers are O digits and then step 12 and 13 are skipped Note 2 Y parameter has 5 digits from left to right is 1 5 each digit s definition is as follow 1 0 twice weighing printing mode 1 once weighing printing mode 2 0 invalid power saving 1 valid power saving 3 0 Kg as weighing unit 1 Tas weighing unit 4 0 weighing record has no cargo NO 1 weighing record has cargo No 5 0 weighing record has no truck NO 1 weighing record has truck No Note 3 1 Only when filling printing type selected deduction ratio can be applied 18 Printing format refers to appendix Filling printing type can use specialized non carbon copy and
5. TARE weight and store to RAM XII Power saving When power saving function is set to valid indicator will come to power save mode after the scale is on ZERO point no TARE has been done for 30 seconds LED display will be off and keep status indicating light Now you can press any key can wake indicator up Power saving function s setting please refer to Y parameter of printing setting XIII Check the software version In weighing mode press print set and input password 30 and then press input indicator will show Ver is the version of this indicator s software Press weigh to go back to weighing mode 21 Chapter Four Maintenance and Cautions 1 To guarantee the clarity and using life the indicator shouldn t be placed directly under sunshine and should be placed in the flat place 2 The indicator should avoid dust pollution vibration and moisture 3 Load cell should connect with indicator reliably and the system should be connected into ground properly The indicator must be kept away from high electrical and magnetic field high corrosion flammable and explosive objects A Do not apply this indicator to the environment with flammable gas or steam and the indicator can not be applied in the system with pressure tank A Inthe area where thunder is frequent happen it must install anti thunder devices to ensure operator s safety and prevent indicator and other device will be damaged by thun
6. XOR 2 3 8 99 2 Order method tF 1 Indicator output corresponding data according to upper monitor s order Each order each frame of data Upper monitor sending order as follow if Sa start address S N order A handclasp order B read G W Order C read TARE XOR 2 93 Indicator Upu content Content and note AA start address S n 4 Output Output corresponding data according to order data according to order _ __ Output corresponding data accordingtoorder m1 Output corresponding data accordingtoorder n Outputcorresponding data accordingtoorder XOR 2 3 n 1 n Indicator output 4 n data content as follow 6 units of data for each Order B G gt format 14 units of data for each sibel bor or G W SM eb 6 bits fromhightolow o to low decimal from h decimal from right to left O 4 _ to left 10 Order C Tare format 14 units of data for each a symbol or b Tare 6 bits from high to low decimal from right to left 0 4 h Order D N W format h decimal from right to left 0 4 Order E Truck No format highest bit of Truck No second bit of Truck No from high to low lowest bit of Truck No Order F Cargo No format a highest bit of Cargo No Note 1 confirmation of XOR checking 4 bits of High and low if it is lt 9 then to plus 30h and being ASCII to send For example if it
7. current display weight is 70 15 then indicator continuously sending like this 51 07000 51 07000 51 07000 Chapter Three Operation Start and Start with Auto zero Connect AC or external battery and turn on the indicator it will perform 999999 000000 self checking then it will enter weighing mode The self checking can be stopped by pushing any key While indicator is on if loading weight on the scale deviates from the zero point but still within zero set range the indicator will set zero automatically Start Zero range selecting setting method please refer to relative chapters While normal operation the calibration switch should be on the spot of calibration forbidden Left Manual zero semi auto zero Press ZERO key to make indicator zero and the zero indicating light will be on 12 2 when display weight deviate from ZERO but in the range of ZERO ZERO key valid otherwise ZERO will be invalid the parameter setting and setting method of ZERO range refers to calibration user s manual 3 Only when STABLE light is on ZERO is allowed to operate ll Tare function 1 Normal Tare When Indicator at weighing status and displaying positive weight stably press Tare key indicator will deduct the displayed weight value as tare weight and now indicator shows N W is O TARE light is on 2 Preset tare When Indicator at weighing status press Pre Tare key and indicator will display P now i
8. is 6 plus 30h then it equals 36h that is 6 in ASC Il code to send out if itis gt 9 then plus 37h that will become a letter of ASCII to send out For example it is B plus 37h equals 42h that is B in ASCII to send out 3 Upper monitor sending order list set indicator communication address as 01 4 Setting of indicator communication parameter 1 Communication parameter Communication parameter consists of communication address baud rate and communication method 2 Communication parameter setting procedure 1 Press Print In weighing mode setting 11 2 Input setting password 98 Press 9 8 Press Input Adr Communication address 01 26 Press 1 Ad r 01 Forexample 1 Press Input bt Serial communication baud rate definition of O 4 Press 1 bt 1 Baud Rate 600 1200 2400 Press Input 4800 9600 tF Serial communication method Input 0 tF 0 O continuous method no receiving Press Input 1 order answer method 2 old D2 continuous communication method each frame 8 bits 3 new D2 continuous D2 communication method each frame 9 bits Note 2 For example O0 Weighing mode End of communication parameter setting Note 2 old D2 continuous communication method output data in ASCII each frame with 8 bits include decimal Data transmit from low to high each frame divided by Sending data is N W the displaying weight on indicator if
9. line of control output in and out 7 Company kindly notice before using our indicator please check and inspect the indicator Our company only be responsible to the quality of indicator itself the maximum compensation of indicator s malfunction will not be over 2 times of indicators own value We are not responsible for the problem of the system where indicator is applied 22 8 Indicators external interface must be used strictly according the our user s manual Random changing of the connection is forbidden During the using of this indicator if any problem happened please unplug the power plug and send back to factory for repair Unprofessional weighing products manufacturer is not allowed to repair it by them to prevent from more damage and loss THIS INDICATOR IS NOT ALLOWED TO OPEN IT AT RANDOM OTHERWISE NO GURANTEE WILL BE ENSURING 9 Battery is a consuming product not in the range of guarantee A inorder to extend the life span of battery please use it after fully charged In a long time not using the battery please charge is in every 2 moths each time for 20 hours charging A in transportation or installation it must be handled with care and light operation avoid any fierce vibration concussion hit to prevent inner electronic circuit s short connection and damage of battery 10 Built in printer head and printing ribbon is consuming product not in the range of guarantee A Forbidden to use built in printer i
10. printing paper to fast print in triplicate Or specialized normal printing paper to fast print in one copy amp Users may need specialized format of filling printing please contact Dealers 2 Indicator s data storage and printing is simultaneous use print key store a unit of complete data meanwhile it is printed out if printing setting is valid 3 if there is any reason like printer false which leads incomplete printing after false is gone press Supply print to supplement print the current saved data 4 after a series of weighing is done press accu print to print the accumulative weighing result of this group of record 5 when twice printing mode is set use empty to loaded truck or loaded to empty truck after first storage indicator only shows LoAd about 1 5 seconds to hint the operator without any printing because this group of data is incomplete But if you print supply print can still print out this incomplete data Print result will be always serial number is blank 2 G W and N W is 0 G Tare weight is current displayed weight Twice printing mode s setting please refer to Y parameter of printing setting 6 When one time weighing mode is applied each weighing will be considered as a complete record to store and print If the indicator is in the TARE mode then current TARE weight will be considered as record TARE weight If indicator is not in TARE mode then it will call the corresponding TARE
11. weight of such truck No as recorded TARE weight if there is not memorized TARE weight then this record s TARE weight will be 0 One time printing mode setting refers to Y parameter of printing setting 7 When built in printer is applied printer model 5 and it is in the weighing mode weighing key will be performs as paper rolling 19 IX A Report printing Press print set then press 1 press input to print sorted statistic daily report of current date That is current date s statistic report by time order report by truck No report by cargo No if you want to print previous daily report please change system s data to the day you need then followed the above steps to print it After printing and change the date back to current data Press print setting press 2 press input to printer report 1 by time order Press print setting press 3 press input to printer report 2 by truck No Press print setting press 4 press input to printer report 3 by cargo No Press print setting press 5 press input to printer report 4 all truck No and its memorized TARE weight statistic report Delete of Data record this indicator allows methods of deleting data as follow 1 Delete all record Include all truck No and memorized tare weight 2 Delete one truck No this truck No s memorized TARE weight and corresponding weighing results When use any method to delete record indicator
12. will show Sure O please choose YES or NO to confirm When sure not O press input to confirm If you want to deny it let Sure 0 then press input or weigh to exit operation method 1 Method in weighing mode and calibration switch is on the forbidden spot left side press Func to delete all weighing record 2 method 2 in weighing mode press truck No and input one truck No then press ZERO can delete this truck number and its corresponding memorized TARE weight and corresponding record Data can t be recovered after delete Be Cautious on this operation to prevent 20 lost of DATA A After calibration or amend printing parameter please delete all weighing record XI How to input memorized TARE weight Indicator and memorize 1000 TARE weights input method are as follow 1 Input TARE weight with numeric keys is original setting value Input truck No E g Input truck o 35790 No Press input PAR Input Tare weight E g 1000 kg Input Tare P 01000 weight Press input O bekto weighing mode 2 weighing mode to store TARE weight In TARE weight display mode drive empty truck on platform when scale is stable press store TARE key then input truck No and press input 3 when each group of weighing record is store if there is no memorized TARE weight of this truck No then TARE weight of this group of weighing record will be considered as this truck s memorized
13. XK3190 A9 Weighing Indicator USER S MANUAL Morr lj a weg U l Chapter One Technical ParamMmeterl ccsscsscescsesscsssccssscssscesseecescesenseess 3 Chapter Two Installation ssesosssoesseesseecsecosssossseeseeeoseossssossseeeseeoseosssssse 5 I Indicator front and back scheme PETAT 5 II Connection between Load cell and indicator 5 ll Connection between Printer and Indicator annb IV Connection between Scoreboard and indicators seed V Connection between Serial communication interface and LIVI CAC ON secs soa sncceaaaseansncce casa A EN eR Chapter Three Operation sssssessesssesseesoossosssessseeosecossoossoeesseeosecoseoosssssseses 12 I Start and Start with AUTO ZELrO ssscescceccssscssscsscescessceeseseces L2 Il Manual zero semi auto zero s ssossossssessssossoossosssossosessssesss L2 III Tare function eases E Le IV Setting and Sperdbn of Date and Time AEE E co V Battery application T VI Inner code diS DlaVconann aa T A S VII Saving for Data KELE o g o REE E A A A R LF VIII Printing ODEON anian a LO IX Report X Delete of Data record EEE ssseeeeeee2O XI How to input memorized TARE Weights E a XII Power saving a2 XIII Check the Na Verslo esrara oera oer r L Chapter Four Maintenance and Caution cscsscescescsescccssccsssccsscesseses 21 Chapter Five Information INCGICATION cccsccccceccssssesssccssscescescesce
14. argo 1001 unit of weighing record AC 220V 15 4 10 50Hz 2 2 Adopts 6V 10AH battery external Battery application About 24h fully charge without using the built in printer About 30h s00mA 0 C 40 C 25 C 55 C lt 85 RH 15 min 310x195x186 mm About 2 5kg Chapter Two Installation I Indicator front and back scheme ES 190 494 We lg het Uridic ator Graph 2 1 Front View Graph 2 2 Back View ll Connection between Load cell and Indicator 1 The 9 pin socket is used for connection with load cell which foot definition is 5 shown in graph 2 3 2 If 4 core shielded cable is used S must be short connected with E so did S and E 3 A Indicator must be reliably connecting to Load cell and shielded cable of load cell must be reliably connected to underground If indicator is powered on the user should not plug or unplug in order to protect the indicator and load cell 4 A Load cell and indicator are static sensitive devices you must adopt anti static measures In order to protect the operator indicator and relevant devices you should install lightning rod in the thunderstorm frequently happening area E S Shield a ey 2 gt CFG ORe E S IN N Terminal of Indicator Terminal of Sensor 6 E a Bridge of Power Supply 2 s QE ORA IN 5 Shield Graph 2 3 Connection of the load cell lll Connection between Printer and Indicator 1 The printing inte
15. der A Load cell and indicator are static sensitive devices you must adopt static free measure Strictly forbid welding or other super electric field operation on the platform In the thunder storm season it must be installed with reliable anti thunder device to prevent any damage to load cell and indicator from thunder and ensure operator s safety and weighing device or other related device s safe operation 4 Itis strictly forbidden to clean the case of indicator with intensive solvents for example benzene and nitro oils b Liquid and electrical conducting particles should not be poured into the indicator otherwise the electronic components will be damaged and electric shock is likely to happen 6 You should cut off power supply of indicator and relevant device before you pulkin and out the connecting line of indicator and external device A You must cut off power supply of the indicator before you plug the connecting line of the load cell in and out A You must cut off power supply of the indicator and the printer before you plug in connecting line of the printer A You must cut off power supply of the indicator and the scoreboard before you plug connecting line of the scoreboard in and out A You must cut off power supply of the indicator and the master computer before you pull connecting line of communication in and out A You must cut off power supply of the indicator and upper monitor before you pull connecting
16. ise current date and let it not smaller than stored weighing record s date lll Wrong connection information indicating 1 It means the printer has trouble or wrongly connected Press any key to quit Reconnect the printer or change the printer 2 jErr 01 It means the load cell signal line is wrongly connected or its signal is negative or exceeds the range our indicator s input signal 1 If this scale is in working previous working good then can judge that the wire connection is malfunction or load cell is damaged 2 If this scale hasn t been calibrated the user should check the load cell s connection wires is correctly connected or load is working properly 3 It means the load cell s wires are wrongly connected or the signal value exceeds the A D converting range 1 If this scale is in working previous working good then can judge that the wire connection is malfunction or load cell is damaged 2 If this scale hasn t been calibrated please check as following a Check the load cell s connection wires is right or not carefully b Check if load cell is suitable or not It should satisfy the following terms The load cell s empty scale loading capacity scale s capacity lt load cell s Capacity AD works in false 1 If 4 pin shielded cable is applied please check if you had short connected the E and S E and S 2 Please check if the connection of load cell is correct IV Error of componen
17. n the environment of dust A Please don t use built in printer while battery is charge A While printing please don t pull out the paper to prevent damage to printing head A Please keep dry and clean of the printing head to extend the life span 11 In condition of normal operation indicator will be guaranteed in one year since the day of purchasing Non manual malfunction is in the range of guarantee please send goods together with guarantee card S N must be corresponding back to supplier for repair Manufacturer provides lifelong maintenance of the indicator Chapter Five Information Indication I Normal information 1 Wait a moment inner operating don t make any operation 2 Wait a moment the data are being transmitted between indicator and printer 3 LoAd Data is storing ll Error information indicating 1 Overload warning unload part of all loading weights 2 Err 19 Zero or Negative weight value can t be printed 3 Err 11 dissatisfying demands of document format or printing set is wrong Please make new setting 4 Err 12 dissatisfying demands of the printer set Printer selection or setting is wrong please select and change the printer 23 5 Date or Time is illegal please input right time and date 6 This truck No does not exist 7 r 10 The truck No stored exceeds 1000 8 printing date is smaller than stored weighing record s date Please delete the larger date record or rev
18. ndicator shows the original TARE weight If a new TARE weight needs to be set please input it by Numeric keys press Input to confirm it 3 Call Tare by truck No In weighing mode press Truck No key indicator will display o input correct truck No then press Tare indicator will find the corresponding Tare weight from the RAM In weighing mode continuous TARE is allowed When tare weight is zero TARE indicating light is off when indicator matches the condition of ZERO press ZERO to make TARE as O TARE light will be off IV Setting and operation of Date and Time 1 In weighing mode press date to display current date and the date light will be on If it is correct press input or weigh to exit if the time is wrong then input the right time by numeric keys then press input to confirm 2 In weighing mode press time time light is on and indicator shows current time and running automatically If the time is right press input or weigh to exit if it is wrong input right time by numeric keys then press input to confirm V Battery application 1 When only use battery as power battery indicting light will tell the volume of battery on the left of display When battery is full 3 indicating lights will be on when voltage is almost full the 2 indicating lights will be only when only 1 light is on that means the battery is low Then you need to charge the battery when voltage is around 5 5V indica
19. ng storing TA is empty and loaded truck or loaded and empty truck Display Empty truck on Press print OSETE Original truck No platform wait for stable light is 27 areas POO el new 2 aa o 00123 If needs original truck No No press input directly no need to change 3 _ Press input Original cargo No input new cargo E g 11 hn 011 If needs original cargo No No press input directly no need to change 5 Press input LoAd Back to weighing mode in 1 5 seconds loaded truck on Press print o 00123 Truck No of step 2 the platform wait for stable light is on 7 Pressfinput hn 011 CargoNo ofstep3 8 Press input Prnt _ printweighingresult Note 5 if the first step is loaded truck then step 6 should be empty other operation is the same IV Pre set TARE weight and auto printing weighing bill Display 1 _ Press print set Select 1 auto electi gure panting _ E R Press 1 Auto 1 Press input type n no need to amend 4 Press weigh Back to weighing mode S p pee e TARE ET a S TARE 7 __ Press input 100 fo Loaded truck 400 Loaded truck 500 minus on the TARE weight 100 platform po fo Pra Auto print weighing bill V Printing weighing bill by calling TARE weight according to truck No step condition display tere Oe been preset Titers tptesen a wait for stable light is on tr
20. pe or non truck No type see chapter of Printing If set non truck No type all operation or printing content related to truck No will not be existed Also indicator s data storage can be set according to cargo No or non cargo No details see Chapter of printing setting A When Data is not stable or G W lt 0 or N W lt 0 the data can not be saved 5 About auto storage or printing 1 auto storage printing setting refers to printing setting chapter 2 auto storage of printing does not contains for twice storage method 15 3 Stored truck No and cargo No is the truck No and cargo No which has been stored before 4 Auto storage TARE can be divided as follow three types 1 when TARE light is on current TARE weight will be saved to this unit of record 2 when TARE light is off indicator will find TARE weight under this truck and take this TARE weight to save in this unit of data 3 when TARE light is off and there is no such TARE in RAM then it will save O as TARE weight to this unit of record 6 If truck No is over 1000 indicator will show Err 10 then you can refer to Chapter 7 to clear one truck No or all truck No Vill Printing operation Printing set Table 3 2 Displey Press print set P 00 Input 97 Press 9 7 P 97 Press Input Press 1 Auto Selecting Auto Manual Printing Press Input Auto 1 0 Manual 1 Auto 5 Built in micro printer only for A9 P 6 External thermal p
21. rface adopts the standard parallel interface The 25 pin RS232 socket is illustrated below Signal Output aI JMV TZ W010 Te DS D4 EBUSY J G a Oo g O88 OW a amp G4 49 49 GD w w w w a Gd GND 2 Caution for Printing A Printing function must be set in indicator before using it A Printer and Indicator s interface must be connected by professional printer connection wire If the connection of each foot is wrong it will damage indicator s output interface or printer s input interface or worse will be damage of indicator or printer A When you use printer you must make sure each pin of the interface is correctly connected then turn on the indicator and turn on the printer at last When you stop using the printer you must turn off the printer first then off the power of indicator and then disconnect the wires If the order is wrong it may damage the indicator and printer Please NOTICE THAT A Due to the various type of printer exists in the market which has different function and capability please use the printer with the model which we recommended A Printer must connect with GND reliably Otherwise it may interfere the normal function of indicator or damage the indicator and printer IV Connection between Scoreboard and Indicator A Interface of indicator for scoreboard s and scoreboard s connection must be correct if there is any mistake on that it will damager the indicator interface and
22. rinter POS58 3 Press 3 Auto indicating Selecting printer Press Input light is on O invalid printing Type 1 TPup16 micro printer English Type 3 2 TM800 printer 3 Panasonic KX P1121 Printer 4 Epson CQ 1600K LQ 300K Panasonic KX1131 T58D etc 16 Press 5 0 Press Input Press 3 Press Input Press 1 0 0 Press 0 5 Press Input Press 1 Press Input Press 1 Press Input Press 0 1 1 Press Input Press 8 Press Input HL HL 50 L001 00 y Y 00011 17 Selecting Printing Restriction 00 print only when display returns zero 25 print only when display lt 25 F S 50 Print only when display lt 50 a 75 Print only when display lt 75 F S 99 Print even when it is at F S Selecting Printing format Arr 0 record format 1 1 page format 2 2 page format 3 3 page format Setting the minimum auto printing weight L must be larger than 10 divisions E g 1 00 Setting paper rolling lines 030 E g 05 Selecting blank filling print format O blank filling print not selected 1 blank filling print selected 2 apply horizontal page print Selecting the deduction rate at blank filling print form O deduction invalid 1 deduction valid Y s definition refers not Note 4 non O number will be all considered as 1 Select Tel No digits O 8 0 no print Tel No 1 8 print Tel No in continuous sheet form
23. scoreboard s input interface or even worse the indicator and scoreboard will be damaged The wire for connection must be assorted professional connection wire 1 Scoreboard adopts 15 core RS232 socket share with serial communication interface the definition of foot 9 and 10 is as follow graph 2 5 RS232C 2 insur GND TXD RXD IN IN OUT OUT OUT OUT connect to scoreboard TX RS23 2 scoreboard output Graph 2 5 serial communication and scoreboard output interface 2 Scoreboard adopts current loop or RS232 by ACII code serial output baud rate is 600 Each frame has 11 bytes of data 1 start bit 0 8 data bit lower bit is in the front 1 stop bit 1 3 Every unit of data is send out in every 100ms each unit of data contains 3 frames data its definition is as follow 2 6 First frame 0 TS SS SS SE SY SS CY CS a l 7 3 4 5 6 7 31 9 10e i dQ dl d2 ds dt d5 dG d mb 5 t a i r t t k P X T G18 G16 G17 Graph 2 6 1 first frame wave graph Second frame d dl d2 d3 d4 d5 d6 d7 tage y xs ce g cg Gib Graph 2 6 2 second frame wave graph Third frame le ct y zang 5 t P m o go a kgd a J Graph 2 6 3 third frame wave graph First frame data mark bit is O X DO D1 D2 is the location of decimal 0 4 Y D3 is weight symbol 1 negative O positive D4 back up G 18 G16 Weight N W data
24. ssceeeses 23 Appen arasen a E REER 25 DEAR USERS PLEASE READ THIS USER S MANUAL CAREFULLY BEFORE USING THE INDICATOR Chapter One Technical Parameter A 5 type of A D Excitation power DC 5V able to connect with 8pcs of 3500 load cells or 16pcs of 700Qload cells 6 wire method long wire auto compensation method indicating lights 25 20720 50 300 optional Clock Can display year month day hour minute second auto reap year and moth Function keys 15 10 of them are share with number keys for combine application Material for keys Light touch type of pellicle Scoreboard connection Serial output interface Baudrate oo Transmission method Baud rate 10 bytes 1 byte is start 8 data bytes ASC II code 1 byte is stop RS422 RS485 lt 1200m Standard parallel output TO connect with TpuP 16 micro printer wide line printer like M800 KX P1121 KX P1131 LQ300K LQ1600K POS58 T58D thermal micro printer interface Built in printer for A9 P Printing system dot matrix 96 dots each line adopts M 150 II printing head or TpuP 16B printing head Printing paper standard blank paper width 44 5 0 5mm thickness 0 07mm paper roll external diameter less then 50mm Life span for Printing head 0 5x10 lines Printing ribbon blue ribbon are installed in the removable ribbon box its life span is 1x10 lines Data saving 1000 units of truck No and tare 201 unit of c
25. tor will cut power to protect the battery automatically 2 connect battery to indicator then connect the AC power indicator will charge the battery automatically fully charge need about 30 hours 3 The battery should be fully charged for first time running 4 battery connection line marks red socket is positive connects with battery s 13 positive pole black line is negative is to connect with battery negative pole 5 if positive and negative pole is connected reversely it will make fuse broken to protect the battery Now connect two poles correctly and restart the indicator it will work normally again Battery is consuming products not in the range of guarantee VI Inner code display pa In weighing mode press print set then input 2 8 indicator will enter into inner code display mode and inner code light is ON Press print set input 2 8 indicator will exit inner code display mode inner code light will be off 2 In inner code display mode only ZERO Print set key is available other keys are all unavailable 3 20 inner code equals 1 division E g while n 3000 the full scale s inner code is 60000 code VII Saving for Data record 1 Indicator regulates that truck No should be 5 digits cargo No is 3 digits The maximum storage is 1000pcs of truck No 201pcs of cargo No 2 Every complete unit of weighing record is stored indicator will print out this unit of data if printing se
26. ts and solving method 1 Key board has problems It will indicates for ten seconds then indicator enters weighing mode Change the keypad 2 The data is partly lost in RAM Operator should switch the calibration on and restart the indicator to self check If there is no Err 20 then switch the calibration off 3 Calibrating data have been lost in RAM and EPROM Operator must plug 24 in the calibration plug then re input the original calibration data turn on the indicator again or re calibrate it 4 RAM has been damaged change the chips and re calibration 5 EPROM has been damaged change the chips and re input the original data re start the indicator or re calibration 6 built in printer is malfunction press any key to exit Exam inner printer connection wire or change the printing head and driver board APPENDIX Appendix l Erect bill format Weighing bill Weighing bill Weighing bill 0001 2008 01 01 022 C No 022 Weighing bill Record format Horizontal bill format 2 000 kg 0 300 kg 1 700 kg Weighing bill date 2008 01 01 N W 6 800 kg Filling type format printing only needs 5 seconds Ww mm A WEIGHT BILL P 1 Wer ef in Fa Operator H VEHICLE No O X N A z a fe CARGONo ss 1580 ke HIZ DISCOUNT 25 1350 ra 7 REMARK Appendix 2 report format example applicable for printer type 2 3 Daily report 1 Date 2008 01 01 0002 1203 24 12345
27. tting is valid 3 Data storage has follow 3 methods 1 Store empty truck then full truck store or store full truck store then empty truck store That is to say twice storage consists of a complete unit of record 2 Full truck for weighing and TARE has been obtained one time storage will form a unit of complete record 3 The weight object is a kind of cargo not a truck then one time storage will form a unit of complete record for always In order to automatically recognize the above three types of storage XK3190 A9 makes following special agreement A Truck No must be any number from 00001 99999 that is 00000 can not be a real truck number If truck No has been set as 00000 that means it is not a truck but a 14 cargo A Cargo No must be any number from 000 200 A Ifthe TARE light is on that means TARE weight is obtained so one time storage will form a complete record A Ifthe truck No has been set as any 5 digit number over the range of 00000 and the TARE light is OFF G W weighing mode then twice storage will forma complete unit of record 4 Storage operation method Table 3 1 1 Press Print In weighing mode i oy 2 Press numeric keys Orta Input Truck No to input truck No o 03217 E g 03217 Press Input 3 Input cargo No Input cargo No Press input E g 35 Press 10 Input percentage Press input of deduction ratio E g 10 Indicator s data storage can be set as truck No ty
28. uck No nput needed truck No g 00123 000123 If the original truck No is corresponding press tare directly no need of inputting truck No 3 press _ Minus stored TARE weigh 28 tare print ee ee a input nput new cargo No E g 11 hn 011 If the original cargo No is Ea EPT corresponding press tare directly no need of inputting cargo No input o a a d 1 Peeteweinsmeis shows negative weight tare VI set various truck preset TARE weight and manually print weighing bill step condition display 1 press o Original truck No truck No 2 Input new truck NO dN 00123 o 00123 If original truck No is needed press input directly no need to input new truck No 3 press P Preset tare weight input 7 A Input preset tare weight E g 100 P 100 iL es input Store various truck s preset Set various truck s preset TARE weight TARE weight step1 5 Loaded truck is on press Original truck No platform wait for stable truck No light is on ee a tare weight press fo Needed truck No Pt press fhm Original cargoNo 11 Input new cargo No OnE 11 hn If the original cargo No is 011 corresponding press tare directly no need of inputting cargo No input Truck leave scale indicator Back to weighing mode Input new truck No E g o 00123 If the original truck No is 00123 corresponding press