Home
ROC800L Field Conversion Guide - Welcome to Emerson Process
Contents
1. Files of type My Nel File name ROCLINKS00 Places Files of type User Programs elf elf gz tar v Cancel Figure 7 Select User Program File Issued Dec 10 9 ROC800L Field Conversion Guide 6 Select the path and user program file to download from the CD ROM As shown in Table 1 the User Programs folder contains all the program files As Figure 8 shows the screen lists all valid user program files with the TAR extension Select User Program File Look in E Liquid Calcs do E LiquidCalcs 600L_1_01_00 tar ik a My Recent Documents in My Documents Miollnir My Network File name LiquidCalcs_800L_1_01_00 tar Places Files of type User Programs elf elf gz tar Cancel Figure 8 LiquidCalcs User Program File 7 Select the program file and click Open The User Program Administrator screen displays As shown in Figure 9 note that the Download User Program File frame identifies the selected program and that the Download amp Start button is active Issued Dec 10 Issued Dec 10 User Program Administrator Device User Program Environment Used Free SRAM 1604 100796 DRAM 41376 17670144 FLASH 35328 FSF 7344 User Programs Installed in Device No Program No Program No Program No Program No Program No Program No Program Sea gar Sap All Option Download User Program File ROC800L Field Conversion Guide Library Version 27
2. 0 Mame No Program Version Library Yersion Created DAAM Used Handle FLASH Used O Entry Pt Proc ID Displays Restart Counter jo Statues Empty Reset Counter D User Programs Liquid Cales LiquidCalcs_S00L_1_01_00 tar d Download amp Start Download Update Close Figure 9 User Program Administrator 8 Click Download amp Start to begin loading the selected program A verification dialog displays Confirm Download 2 Download User Program 1 9 Click Yes to begin the download When the download completes a completion dialog displays ROCLINK 800 Il Download amp Start User Program COMPLETED 11 ROC800L Field Conversion Guide 10 Click OK The User Program Administrator screen displays see Figure 10 Note that The Device User Program Environment frame reflects the use of system memory The User Programs Installed in Device frame identifies the installed program s The Status field indicates that the program is running User Program Administrator Device User Program Environment Used Free SRAM 26570 T5830 DRAM 1126400 17285120 FLASH 231936 3380736 Library Version 27 0 User Programs Installed in Device LiquidCalcs_800L Marne LiquidCales_800L No Program No Program Version 1 07 00 Library Version 27 0 Ho Program ne l Mo Program Created 0872072010 15 3704 DRAM Used 356352 g No Program Handle 1 FLASH Used 1914
3. 66 Loran None Entry Pt Ox2F 81 84C Proc IO Ox1005F Clear Start Stop Reieplays 200 201 202 203 204 Restart Counter 0 All Option Status Running Reset Counter Download User Program File DAU ser Programe Liquid Calcs4LiguidCalcs_800L_1_01_00 tar Browse Download amp Start Download Figure 10 User Program Administrator with LiquidCalcs Installed 11 Repeat steps 4 through 10 for each program you want to include in your ROCS800L When you have successfully installed all the programs you need proceed to verifying the conversion Verifying the Conversion To ensure that you have correctly installed the appropriate programs review the content in the User Program portion of the directory tree on the left side of the ROCLINK 800 display see Figure 11 12 Issued Dec 10 ROC800L Field Conversion Guide ROCLINK 800 On Line Com1 ROCBOOL Remote Oprtns Cntrir SEE File Edit view ROC Configure Meter Utilities Tools Window Help 0 x D W i Wh Wi SeORR HR 2 On Line Comi ROCSOOL Remote Oprtns Cntrlr 1 0 amp Control A Meter f A Me System 2 History Displ ay 200 User Program LiquidCalcs Administrator Program 1 LiquidCales_800L Display 200 Liquid Preferences Display 201 Liquid Product Display 202 Liquid Density Interface Display 203 Liquid Station Display 204 Liquid Meter 29 Program 2 BatchQueue_800L Display 15 Batch Queue Con
4. Form A6305 Part Number D301683X012 December 2010 ROC800L Field Conversion Guide Remote Automation Solutions EMERSON ROC800L Field Conversion Guide Revision Tracking Sheet December 2010 This manual may be revised periodically to incorporate new or updated information The revision date of each page appears at the bottom of the page opposite the page number A change in revision date to any page also changes the date of the manual that appears on the front cover Listed below is the revision date of each page if applicable Page Revision Initial issue Dec 10 NOTICE Remote Automation Solutions RAS division of Emerson Process Management shall not be liable for technical or editorial errors in this manual or omissions from this manual RAS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND IN NO EVENT SHALL RAS BE LIABLE FOR ANY INCIDENTAL PUNITIVE SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PRODUCTION LOSS OF PROFITS LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL FUEL AND POWER AND CLAIMS OF THIRD PARTIES Bristol Inc Bristol Canada BBI SA de CV and Emerson Process Management Ltd Remote Automation Solutions division UK are wholly owned subsidiaries of Emerson Electric Co doing business as Remote Automation Solutions RAS a d
5. Installing the Software Five programs Liquid Calcs Batching Batch Queuing Proving and Reporting work together to provide ROC800L functionality Using the Liquid Calcs program you configure your liquid preferences and perform all liquid calculations Liquid Calcs 1s actually the only required program The other four programs provide additional functionality Consequently if your organization does not need proving or batch queuing functions for example you can choose not to install that program If your organization requires that function later you can install that program However you must install and run the Liquid Calcs program first The User Programs folder on the CD contains the following files Table 1 ROCSOOL Program Files Folder Name Program File Liquid Calcs LiquidCalcs_800L_1_01_01 tar Batching Batching 800L_1_01_01 tar Batch Queue BatchQueue_800L 1 01 00 tar Proving Proving 800L_1 01 01 tar Reporting Reporting 800L_1 01 _00 tar This section details the process of installing the LiquidCalcs program into flash memory Follow the same process to install any of the other programs you select Installing the LiquidCalcs Program To install this program 1 Connect the ROC800 to your computer using the LOI or other available comm port Note We recommend using the Ethernet port to speed program downloads 2 Start and logon to ROCLINK 800 3 Select Utilities gt User Program Administrator from the
6. ROCLINK menu bar The User Program Administrator screen displays see Figure 6 Note Ifthe User Program Administrator option is initially grayed out you may need to disconnect and reconnect with the ROC 8 Issued Dec 10 ROC800L Field Conversion Guide User Program Administrator Device User Program Environment Used Free SRAM 1604 100796 DRAM Ff41s b 17670144 FLASH s6320 35ra Library Version 27 0 User Programs Installed in Device Mame No Program Mo Frogram Mo Program Yeron Library Version Ao Program No Program Created DRAM Used 0 Mo Program Handle FLASH Used No Prograrn Ao Frogram Entry Pt Proc ID C Displays Restart Counter Status Empty Click Browse Download User Program File Browse mo Update Close Figure 6 User Program Administrator 4 Select any empty program number in this case number 1 into which to download the program 9 Click Browse in the Download User Program File frame The Select User Program File screen displays see Figure 7 Select User Program File gt ite P ROC8OOL Firmware My Recent user Programs Documents Desktop Batching My Recent Liquid Calcs Documents Proving Qo Reporting Pi My Documents My Recent Documents My Network File name Places 3 Files of type S Desktop My Documents My N Places File name
7. ect Utilities gt License Key Administrator from the ROCLINK 800 menu bar The License Key Administrator screen displays 2 Issued Dec 10 ROC800L Field Conversion Guide License Key Administrator License Kep H Mum Application Name Provider Hame AppCode Version Quantity valable Expiration Time Created Liquid Calcs Emerson FLD 6 1 0 0 1 0 No Expiration 09 03 2010 15 53 34 AGA 37 8 N Greson FEO eioo 2 DlNoEspiration 09 03 2010 15 54 12 Liquid Calcs license key correctly installed Ee Mas a Hurm Time Created License Kep H2 io X Cancel Figure l License Key Administrator Screen This screen indicates that ROCLINK 800 recognizes the Liquid Calcs license key Proceed to installing the firmware Note The screen also shows the AGA 3 7 8 license key This license is an available option for the ROC800L since it can measure both liquids and gases Installing the Firmware The ROC800L firmware is designed to supports liquid measurements as well as up to six gas runs 1 Using the LOI port connect the ROC800 to a laptop on which ROCLINK 800 version 1 88 or later has been installed 2 Start ROCLINK 800 Note We recommend you change the baud rate for the LOI port to 57 6K before you begin the firmware update 3 Place the CD from the conversion kit in the laptop s CD tray and close the CD tray 4 Select Utilities gt Update Firmware from the ROCLINK 800 menu bar The Update Firmware sc
8. figuration Display 212 Station BE Ngh History Display 213 Meter CurreriNg Display 214 Meter Batch HIN Program 4 Proving_800L Display 206 Prover Configuration Display 208 Prover Data Program 5 Reporting_800L I n stal led i rig 219 Report Configuration ROC800 L ser Display programs Figure 11 ROCLINK 800 Display with Installed ROCSOOL Programs This example shows that all five ROC800L programs have been successfully installed Next verify that the LiquidCalcs program is running Double click Display 200 Liquid Preferences The Liquid Preferences screen displays see Figure 12 Issued Dec 10 13 ROC800L Field Conversion Guide 14 General COSTALD Tait Program Status Program Running Process Variables Pressure Units Gauge fe Psi Kpa Bar Kg em2 Temperature Units DegF C Deg Density Units Kg m3 C g em3 Lb ft3 C Lb bbl C Lb gal C Relative Density C API Gravity C Kg l wa ROCLINK 800 Liquid Preferences Remote Oprtns Cntrir File Edit view ROC Configure Meter Utilities Tools Window Help Dw fd Gt Z Whew ht Se eORRE AR 2 LiquidCalcs program is running successfully Calculation Period f Oo Seconds Yolume Units Bbl C Met C Km3 C Gal C R3 C m3 C Liter Mass Units Lb 9 C Ton C Tonne Correction Table Units Kg m3 C Relative Density C API Gravity Flow Rate Option Per day C Per hour Per mi
9. ivision of Emerson Process Management ROC FloBoss ROCLINK Bristol Bristol Babcock ControlWave TeleFlow and Helicoid are trademarks of RAS AMS PlantWeb and the PlantWeb logo are marks of Emerson Electric Co The Emerson logo is a trademark and service mark of the Emerson Electric Co All other trademarks are property of their respective owners The contents of this publication are presented for informational purposes only While every effort has been made to ensure informational accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchaser and end user 2010 Remote Automation Solutions division of Emerson Process Management All rights reserved ji Issued Dec 10 Guide Overview Kit Contents Issued Dec 10 ROC800L Field Conversion Guide This ROCSOOL Field Conversion Guide details the tasks and materials you need to convert a field located ROC800 to a ROC800L The guide is part of a conversion kit see Kit Contents below a
10. ler Instruction Manual Form A6175 P N D301217X012 ROC800L Field Conversion Guide o ROCS8OOL Protocol Specifications Manual Form A6294 P N D301659X012 o ROCLINK 800 Configuration Software User Manual for ROCSOOL Form 6214 P N D301246X012 o Technical specifications for ROC800L software ROCSOOL Liquid Application Software ROC800 SW1 P N D301576X012 o Technical specifications for ROC800L controllers ROCSOOL Remote Operations Controllers ROC800 800L P N D301678X012 Verify that the area is non hazardous before you begin the following A Warning procedures Failure to do so may result in serious personal injury Installing the License Key 1 Disconnect the ROC800 from all power sources 2 Remove the wire channel cover next to the CPU module If appropriate remove wiring from the CPU module 3 Remove the faceplate from the ROC800 CPU module 4 Place the ROC800L license key in either available terminal slot Note Once installed the ROC800L firmware and software does not require any license key other than the ROC800L license key Unless required for another application we suggest you remove and safely store any extraneous ROC800 license keys 5 Replace and secure the faceplate for the CPU module Restore any wiring if appropriate 6 Replace the wire channel cover next to the CPU module 7 Restore power to the ROC800 Verification To verify that you have correctly installed the license key sel
11. nd identifies the conversion kit components and provides step by step instructions Note The ROC800L software works only on a Series 2 CPU which has a black faceplate The conversion focuses on a field installed ROC800 and enables you to install the necessary hardware firmware and software Follow these instructions to ensure a safe conversion and correct functioning of the ROC800L Note Before you begin the actual conversion read through this manual to familiarize yourself with the parts and procedures required If you need additional clarification refer to the ROCS800 Series Remote Operations Controller Instruction Manual Form A6175 A copy is provided on the CD included in the conversion kit The conversion process involves four major steps Installing the ROC800L license key Loading the ROC800L firmware Installing the ROC800L software Verifying the installation Note These processes assume you are familiar with routine ROC800 procedures Refer to the ROCS800 Series Instruction Manual A6175 for detailed instructions The conversion kit should contain the following items Ensure that you have all of these items before you begin the conversion process One ROC800L license key FS8KY 8 One CD ROM P N W68272X0012 containing firmware software and user documentation o ROCS8OOL Field Conversion Guide Form A6305 this document P N D301683 X012 o ROC8 amp 00 Series Remote Operations Control
12. nute C Per second Linear Units Option Inches C Millimeters Bie Save As Auto Scan 2 Update Close DERE 017 Figure 12 Liquid Preferences Screen The Program Status frame should show Program Running If you have another message such as License Not Found or Program Not Runing use that message to diagnose a possible solution Issued Dec 10
13. reen displays Issued Dec 10 3 ROC800L Field Conversion Guide Update Firmware CPU Firmware Device Configuration Save Device Configuration Before Firmware Update Deselect these two File ame options T EEE Firmware Image to Download File Marne Browse File Information Click to select the ROCS800L firmware Status Figure 2 Update Firmware Screen 5 Unselect both the Save Device Configuration and Restore Device Configuration options by default they are selected 6 Click Browse in the Firmware Image to Download frame A Select Image File screen appears 4 Issued Dec 10 ROC800L Field Conversion Guide Select Image File My Recent User Programs Documents od E Desktop Click to select the ROC800L CD May D ocuments Mjollnir My Network File name Places Files of type ROCEOO Image cli Cancel _ Figure 3 Select Image File Screen 7 Click V in the Look In field to select the ROC800L CD Note The CD contains several folders Misc Doc ROC800L Firmware and User Programs The ROC800L Firmware folder contains the ROC800L firmware file 8 Open the ROC800L Firmware folder and select the ROC800L 1 02 dli file That file should appear in the File name field see Figure 4 Issued Dec 10 ROC800L Field Conversion Guide Select Image File Look ir ROcEOOL Firmware 4 do E My Recent Documents Desktop L Click Open May Documents M
14. y Network File name ROCSOOL_1 02 di Places Files of type ROCBOO Image dli Cancel Figure 4 ROCSOOL Firmware ImageFile 9 Click Open to select that file and redisplay the Update Firmware screen 6 Issued Dec 10 ROC800L Field Conversion Guide Update Firmware fx CPU Firmware Device Configuration Save Device Configuration Before Firmware Update Restore Device Configuration After Firmware Update File Marne Firmware Image to Download File Name 0 SROC8OOL Firmwares ROCSOOL_1 02 dli Browse File Information Image Header BROCTIMACE Image Type hzipe Compression Starting Address OxO1040000 Size 1227841 Version IL DE Time Stamp Te 26224 Tate Stamp Oo8 1l2 2010 TNB xlE3F Click Start Statuz Start Close Figure 5 Update Firmware Screen Completed 10 Click Start to begin the firmware download Since you are replacing the current ROC firmware a verification dialog displays Update Firmware Update current firmware 3 05 ws with version 1 02 11 Click Yes to proceed Changes in the Status messages indicate the progress of the download Once the download completes another verification dialog displays ROCLINK 800 12 Click OK to close the dialog and click Close to close the Update Firmware screen Once you have downloaded the firmware proceed to installing the software Issued Dec 10 7 ROC800L Field Conversion Guide
Download Pdf Manuals
Related Search
Related Contents
Moduli - PAC PROFIBUS DP, SWITCHED ETHERNET Lite-On Internal Slim Slot-in 8x 4x 8x 4x DVD-Dual DVDRW Drive USER MANUAL Disclaimer The instructions in this document have ARROW PROACTIVE COUNTERPULSATION™ USER GUIDE PEL 8K / PEL 8K-M Grundig VIDEORECORDER GV 460 VPT User's Manual Canada - Buyandsell.gc.ca YFA Hybrid foreword.QXP Copyright © All rights reserved.
Failed to retrieve file