Home
User manual - Elite Alarm Solutions LLP
Contents
1. RESET Button for restoring default parameters Battery slots STATUS LED indicator for data transmission indication ALARM blue Blue LED indicators for visual alarm indication ALARM red Red LED indicator for visual alarm indication BUZZER Speakers for audio alarm indication TAMPER Tamper switches 2 FRONT SIDE of ENCLOSURE ALARM blue J ALARM red ALARM blue LED indication Description ALARM blue flashing Burglary 24 Hour or tamper alarm in progress ALARM red flashing Fire alarm in progress EWS3 Wireless Indoor Siren E 3 INSTALLATION tei Before installing the wireless device we highly recommend to refer to RADIO SYSTEM INSTALLATION AND SIGNAL PENE TRATION manual located at www eldes t download 1 Open EWS3 enclosure a Press and hold I b Pull down MOUNTING POINTA Ensure o screw in properly for supervision of the back side by tamper switch MOUNTING POINTB 3 When installing EWS3 follow the recommendations for the installation to achieve the strongest wireless signal gt Wireless device 0 5mto30m 0 5mto150m in open areas Wireless device inside the building EPIR2 Never install in the following locations e inside the metal cabinet e closer than 20 cm from the metal surface and or power lines Recommended e face the front side of the w
2. User Manual v1 0 Compatible with ESIM364 v02 06 09 and up EPIR2 v01 01 12 and up e ESIM264 v7 14 07 and up Main features e Audio alarm indication by 2 built in speakers e Visual alarm indication by built in LED indicators burglary 24 hour tamper alarm and fire alarm indicated in different colours e 2 tamper switches for enclosure opening and device detachment from the wall detection EWS3 is a wireless indoor device with built in siren speakers and LED indicators operating with ELDES wireless alarm systems The de vice is designed to notify the user by audio and visual signals in the event of alarm as well as in event of system arming disarming Bell Squawk feature must be enabled In the event of burglary 24 hour or tamper alarm EWS3 will activate the speakers and flash the blue LED indicators while in case of a fire alarm the device can flash the red LED indicator both features require EWS3 Alarm LED and EWS3 Fire Alarm LED parameters to be enabled using ELDES Configuration Tool software or EKB2 EKB3 EKB3W keypad To start using EWS3 it has to be bind to ELDES alarm system by sending a corresponding SMS message or using software ELDES Config uration Tool Upon successful EWS3 binding process the system adds one wireless zone and one wireless PGM output In case of alarm the siren provides a sound alarm for one minute The configuration of this parameter is disabled for EWS3 in order to save the battery power ESIM2
3. Upon the successful binding process EWS3 device icon becomes visible in Wireless Device Management section as well as Battery Level and Signal Level If attempt to bind is unsuccessful try to move EWS3 closer to the alarm system device and bind anew 9 EWS3 siren is ready for use Aun Ensure that EWS3 device is properly fixed to the wall and the Mounting Point A portrayed in Fig No 4 and Fig No 5 is properly screwed in Otherwise the tamper switch will NOT supervise the back side of EWS3 enclosure see also 4 EWS3 ZONE PGM OUTPUT AND TAMPER ALLA If you are unable to bind the wireless device please restore the parameters of the wireless device to default and try again See chapter 6 RESTORING DEFAULT PARAMETERS for more details EWS3 Wireless Indoor Siren 4 EWS3 ZONE PGM OUTPUT AND TAMPER Upon successful EWS3 outdoor siren binding process the system adds 1 wireless Instant zone and 1 wireless Siren PGM output The wireless zone is intended for EWS3 tamper control and ability to assign a partition s while the wireless PGM output is intended for siren speaker control In case of tamper violation the alarm is caused regardless of system being armed or disarmed There are 2 ways to detect tamper viola tion on EWS3 By tamper switch EWS3 comes equipped with 2 built in tamper switches intended for enclosure supervision one located on the front side of the PCB supervising the front cover in case it is illegally
4. opened see Fig No 1 e the other one located on back of the PCB supervising the back side of the enclosure in case the EWS3 is illegally detached from the wall see Fig No 1 Once the enclosure of EWS3 is tampered the tamper switch will become triggered This action will be followed by alarm resulting in sending an SMS text message and or phone call to the user The SMS text message contains the violated tamper number By wireless connection loss The wireless connection loss between EWS3 and ELDES alarm system leads to alarm The system identifies this event as a tamper violation and sends an alarm by SMS text message and phone call to the user s by default The SMS message contains the violated tamper number and a star character indicating wireless connection loss as a tamper alarm cause ua ul NA The tamper will not operate if the wireless zone is disabled 5 BATTERY REPLACEMENT 1 Open EWS3 enclosure 2 Remove all 4 old batteries from the battery slots 3 Postition the 4 new 1 5V alkaline AA type batteries according to the appropriate battery slot positive negative terminals indicated on the PCB printed circuit board of EWS3 Insert the batteries into the battery slots 5 Batteries replaced See chapter 3 INSTALLATION for more details uuu yA Only 1 5V Alkaline AA type batteries can be used Install only new high quality and unexpired batteries Do not mix the old batteries with the new ones Vay wile At le
5. warranty by the manufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the system has been used as intended following all guidelines listed in the manual and within specified operating conditions Receipt must be kept as a proof of purchase date The warranty is voided if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environment or other force majeure factors Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around DO NOT use the system where it can be interfere with other devices and cause any potential danger e DO NOT use the system with medical devices DO NOT use the system in hazardous environment DO NOT expose the system to high humidity chemical environment or mechanical impacts DO NOT attempt to personally repair the system The WEEE Waste Electrical and Electronic Equipment marking on this product see left or its documentation indicates that the product must not be disposed of together with household waste To prevent possible harm to human health and or the environment the product must be disposed on in an approved and environmentally safe recycling process For further infor mation on how to dispose of this product correctly contact the system supplier or the local authority responsible for waste EE
6. 64 and EPIR2 alarm systems support up to 16 EWS3 devices while ESIM364 up to 32 EWS3 devices The maximum wireless con nection range is 150 meters in open areas ALLA For complete information on device operation with ELDES alarm system please refer to ELDES alarm system user and installa tion manuals located at www eldes t en download 1 CONTENTS OF PACK 1 EWS3 2 1 5V Alkaline AA Type Battery 3 User Manual cocinan inini A AO 2 TECHNICAL SPECIFICATIONS 2 1 Electrical Mechanical Characteristics B tterytypesan nissan 1 5V Alkaline AA type 4 18 months Wireless transmitter receiver frequency anne 868 Mhz 25 55 C Number of batteries Battery operation time Range of operating temperatures Humidity 0 90 RH 00 40 C non condensing Dimensions 167 x 80 x 34 mm Wirelesscommunication range minis Up to 30 meters in premises up to 150 meters in open areas Compatible with alarm systems uuseseenseseneesnnennsnnnennennnnnnennnnn ELDES Wireless The operation time might vary in different conditions 2 EN EWS3 Wireless Indoor Siren 2 2 Main Unit LED amp Connector Functionality FRONT SIDE of PCB BACK SIDE of PCB E TAMPER BATTERY TAMPER BATTERY BATTERY BATTERY FE e ALARM blue RESET ALARM red ALARM blue el STATUS
7. ast 1 battery must be removed if the device is not in use CUNA In order to avoid fire or explosion hazards the system must be used only with approved battery Special care must be taken when connecting positive and negative battery terminals Dispose old batteries only into special collection sites Do not charge disassemble heat or incinerate old batteries ALHA The system sends an SMS message to a preset user phone number as soon as the battery level runs below 5 ALHA The battery status can be monitored in real time using ELDES Configuration Tool software 6 RESTORING DEFAULT PARAMETERS 1 Remove one battery from EWS3 2 Press and hold the RESET button 3 Insert the battery back to EWS3 4 Hold the RESET button until LED indicator starts blinking 5 Release the RESET button 6 Parameters reset to default EN EWS3 Wireless Indoor Siren 7 ADDITIONAL INFORMATION Limited Liability The buyer must agree that the system will reduce the risk of fire theft burglary or other dangers but does not guarantee against such events ELDES UAB will not take any responsibility regarding personal or property or revenue loss while using the system ELDES UAB liability according to local laws does not exceed value of the purchased system ELDES UAB is not affiliated with any of the Internet providers therefore is not responsible for the quality of Internet service Manufacturer Warranty This device carries a 24 month
8. disposal in your area Copyright ELDES UAB 2013 All rights reserved It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by ELDES UAB ELSDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that this wireless indoor siren EWS3 is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes lt EWS3 Wireless Indoor Siren 5 Made inthe European Union www eldes lt
9. ireless device towards the front side of EPIR2 e keep the distance 0 5m to 30 m inside the building 0 5mto150 min open areas in open areas Wireless device Recommended 5mto30m z inside the building face the front side ofthe 0 5mto150m wireless device towards ELDES alarm system s wire less antenna e keep the distance 0 5 m to ELDES alarm 30 m inside the building 0 5 system wireless m to 150 min open areas antenna 4 Remove the plastic tab inserted between one of the battery terminals and battery slot contacts 5 STATUS indicator should start flashing indicating successful data transmission EWS3 Wireless Indoor Siren 6 Close EWS3 enclosure by putting the cover back see Fig No 3 7 Bind the device to the alarm system using ELDES Configuration Tool software Open Wireless Device Management section and enter a 8 digit wireless device ID located on the EWS3 enclosure and press Add button see Fig No 10 The device can also be bind by sending a corresponding command via SMS message For more details please refer to the software s HELP section and ELDES alarm system installation manual less Zone Tamper Alarm Quege A EWF1 D 02000011 TAmper ALARMI CA gt lt Back 1 5 Next gt Search Device ID Wireless Device Management Device ID 58122812 Device Type Temperature Battery Level Signal Level EWF1 CONNECTED 3PC C 0 J 0 8