Home
Rosemount 3051 Pressure Transmitter
Contents
1. 0 0078 of Span Rosemount 3051T Ranges 1 4 0 065 of span For spans less than 10 1 accuracy Span 0 0075 IZ of Span Range 5 0 075 of span For spans less than 10 1 accuracy Spar 0 0075 J of Span Ranges 2 4 High Accuracy Option P8 0 04 of span For spans less than 5 1 accuracy Span 0 0075 J of Span Rosemount 3051H 3051L All Ranges 0 075 of span For spans less than 10 1 accuracy Span 0 025 n 0 005 J of Span Rosemount 3051 Ambient Temperature Effect per 50 F 28 C Rosemount 3051CD CG 0 0125 URL 0 0625 span from 1 1 to 5 1 0 025 URL 0 125 span from 5 1 to 100 1 Range 0 0 25 URL 0 05 span Range 1 0 1 URL 0 25 span Rosemount 3051CA 0 025 URL 0 125 span from 1 1 to 30 1 0 035 URL 0 125 span from 30 1 to 100 1 Rosemount 3051H 0 025 URL 0 125 span 0 35 inH20 For spans less than 30 1 0 035 URL 0 125 span 0 35 inH20 Rosemount 3051L See Rosemount Inc Instrument Toolkit software Rosemount 3051T 0 025 URL 0 125 span from 1 1 to 30 1 0 035 URL 0 125 span from 30 1 to 100 1 Range 5 0 1 URL 0 15 span Range 1 0 025 URL 0 125 span from 1 1 to 10 1 0 05 URL 0 125 span from 10 1 to 100 1 Line Pressure Effect per 1000 psi 6 9 MPa Rosemount 3051CD Zero Error can be calibrated out at line pressure Range 2 3 0 05 of URL for
2. Carbon steel construction with carbon TABLE 16 3051L Weights without Options Flange Flush Ib kg 2 in Ext Ib kg 4 in Ext Ib kg 6 in Ext Ib kg steel bolts 2 in 150 12 5 5 7 B6 B5 Bracket with SST Bolts 3 in 150 17 5 7 9 19 5 8 8 20 5 9 3 J21 5 9 7 Same bracket as the B5 option with Series 300 stainless steel 4 in 150 23 5 10 7 26 5 12 0 28 5 12 9 30 5 13 8 bolts 2 in 300 17 5 7 9 3 in 300 22 5 10 2 24 5 11 1 25 5 11 6 26 5 12 0 Traditional Flange Bracket Options 4 in 300 32 5 14 7 35 5 16 1 37 5 17 0 39 5 17 9 B1 Bracket for 2 in Pipe Mounting 2 in 600 15 3 6 9 Em e For use with the traditional flange option 3 in 600 25 2 11 4 27 2 12 3 28 2 12 8 29 2 13 2 e Bracket for mounting on 2 in pipe DN 50 PN 40 13 8 6 2 e Carbon steel construction with carbon DN 80 PN 40 19 5 8 8 21 5 9 7 22 5 10 2 23 5 10 6 steel bolts DN 100 17 8 8 1 19 8 9 0 20 8 9 5 21 8 9 9 e Coated with polyurethane paint PN 10 16 B2 Bracket for Panel Mounting DN 100 23 2 10 5 25 2 11 5 26 2 11 9 27 2 12 3 e For use with the traditional flange option PN 40 e Bracket for mounting transmitter on wall or panel l l e Carbon steel construction with carbon TABLE ene ie pun Ege steel bolts Add Coated with polyurethane paint Code Option Ib kg B3 Flat Bracket for 2 in Pipe Mounting J K L M Stainless Steel Housing T 3 9 1
3. PIPE MOUNTING BRACKET 3051 3031J19D 119C E1 Certification Label givVE a TA canting Oty k g N Housing Rotation Set Screw 7 9 202 12 14 NPT on Optional Flange Adapters Y Drain Adaptors Can Be Rotated to Give Connection Centers of 2 00 51 2 126 54 or 2 25 57 E gt 28 87 28 Dimensions are in inches millimeters 18 3051 3031E30A D30B Product Data Sheet 00813 0100 4001 Rev FA August 2004 0 75 20 Clearance for 1 3051T Dimensional Drawings 5 0 127 gt 4 3 110 112 14 NPT Conduit Connection Two Places Other Sizes Available 0 75 20 Clearance for Cover Removal af Terminal Connections Housing Rotation Set Screw Rosemount 3051 Certification Label 3051T Typical Mounting Configurations with Optional Mounting Bracket Pipe Mounting Dimensions are in inches millimeters Panel Mounting Cc 120 6 9 175 3051 3051TC6A TB6A 3051 3051TA4A TB4A TC4A 19 Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 20 3051H Pressure Transmitter Exploded View and Dimensional Drawings Secondary Filled System Sensor Module L Process Isolating Diaphragm D yi High Side Process Flange ES S Low Side Process Flange Drain Vent Valve 3051 3051HB2G Flange Bolts 112 14 NPT Two Places Other Label 4 3
4. 00813 0100 4001 Rev FA August 2004 Rosemount 3051 TABLE 13 3051L Flange Mounted Liquid Level Transmitter Code Mounting Flange Size ASME B 16 5 ANSI or DIN Flange Rating Material M 2 in Class 150 CS A 3 in Class 150 CS B 4 in Class 150 CS N 2 in Class 300 CS C 3 in Class 300 CS D 4 in Class 300 CS P 2 in Class 600 CS E 3 in Class 600 CS X 2 in Class 150 SST F 3 in Class 150 SST G 4 in Class 150 SST Y 2 in Class 300 SST H 3 in Class 300 SST J 4 in Class 300 SST Z 2 in Class 600 SST L 3 in Class 600 SST Q DN 50 PN 10 40 CS R DN 80 PN 40 CS S DN 100 PN 40 CS V DN 100 PN 10 16 CS K DN 50 PN 10 40 SST i DN 80 PN 40 SST U DN 100 PN 40 SST W DN 100 PN 10 16 Sc 0o Process Fill High Pressure Side Temperature Limits A Syltherm XLT 100 to 300 F 73 to 135 C C D C Silicone 704 60 to 400 F 15 to 205 C D D C Silicone 200 40 to 400 F 40 to 205 C H Inert Halocarbon 50 to 350 F 45 to 177 C G Glycerine and Water 0 to 200 F 17 to 93 C N Neobee M 20 0 to 400 F 17 to 205 C P Propylene Glycol and Water 0 to 200 F 17 to 93 C Low Pressure Side Code Configuration Flange Adapter Diaphragm Material Sensor Fill Fluid 11 Gage SST 316L SST Silicone 21 Differential SST 316L SST Silicone 22 Differential SST Hastelloy C276 Silicone 2A Differential SST 316L SST Inert Halocarbon 2B Differential SST Hastelloy C276 Inert Halocarbon 31 Remote Seal SST 316L S
5. 110 Sizes Available 0 75 19 M for Cover Removal DT 7 Clearance for Cover Removal Transmitter Terminal Circuitry on ae Connections Housing Rotation Set Screw Drain Vent 1 2 14 NPT on Optional Mounting Adapters 1 2 18 NPT on Process Flange for Pressure Connection Adapters Can Be Rotated Without the Use of Mounting Adapters to Give Adapter Connection Centers of 2 00 51 2 126 54 or 2 25 57 3051 3051i01A H01B Dimensions are in inches millimeters Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 3051H Mounting Brackets for 2 in Pipe and Panel Mount Option Code B5 B6 D 2 A o V 5 Q Impulse Piping g8EVH VEGHLSOE 86LH VELDLEOE LSOE JoynusueJ J 0 JoyYoeIG Buiuoeny 10 perjddns sog v x 02 9 NOILVYNSDISANOD ONILNNOW T3NVd Dimensions are in inches millimeters 21 Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 3051L Dimensional Drawings 2 in Flange Configuring Flush Mount Only 3 and 4 in Flange Configuration Certification Label Certification Label C J Serrated Face ARTON Gasket Surface ROU Housing Rotation Set Screw FIELD al itii Y Lower Housing Gasket 1 2 14 NF 11214 Mounting Adapter NPT optional A Mounting __ 6 5 165 _ Adapter Extension optional 2 4 or 6 51 102 or 152 Optional Flushing Connection R
6. combination of C6 and K8 o KB FM and CSA Explosion proof and Intrinsic Safety Approvals combination of K5 and C6 e K7 SAA Flame proof and Intrinsic Safety Approvals combination of I7 N7 and E7 KB ATEX Flame proof and Intrinsic Safety Approvals combination of 11 and E8 KD CSA FM and ATEX Explosion proof and Intrinsic Safety Approval combination of K5 C6 11 and E8 I7 SAA Intrinsic Safety Certification e E7 SAA Flame proof Certification N7 SAA Type N Certification IA ATEX Intrinsic Safety for FISCO for FOUNDATION fieldbus protocol only IE FM FISCO Intrinsic Safety for FOUNDATION fieldbus protocol only e e 07o Te Bolt for Flange and Adapter Options HD HG L4 Austenitic 316 SST Bolts Ofere Meter Options HD HG M5 LCD display for Aluminum Housing Available with Housing codes A B C and D only M6 LCD display for SST Housing Available with Housing codes J K L and M only e e efTe Other Options HD HG Q4 Calibration Data Sheet e e Q8 Material traceability certification per EN 10204 3 1 B QP Calibration certification and tamper evident seal J16 Local Zero Adjustment Only Local zero and span adjustments are standard unless Option Code J1 or J3 is specified Ja No Local Zero or Span Adjustment Local zero and span adjustments are standard unless Option Code J1 or J3 is specified T1 Transient Protection Terminal Block C1 Custom Software Con
7. 0 88 22 0 88 22 0 75 19 0 88 22 18 mm 18 mm 22 mm 18 mm Rosemount 3051 Exten DIEAS B NA 2 58 66 3 5 89 NA 2 58 66 3 5 89 NA 2 58 66 NA 65 mm 89 mm 89 mm O D Gask Surf E 3 6 92 5 0 127 6 2 158 3 6 92 5 0 127 6 2 158 3 6 92 5 0 127 4 0 102 5 4 138 6 2 158 6 2 158 Proc Side F 2 12 54 3 5 89 4 5 114 2 12 54 3 5 89 4 5 114 2 12 54 3 5 89 2 5 63 3 7 94 4 5 114 4 5 114 23 Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 Ordering Information TABLE 11 3051C Differential Gage and Absolute Pressure Transmitters Not Applicable Applicable Model Transmitter Type Select One CD CG CA 3051CD Differential Pressure Transmitter 3051CG Gage Pressure Transmitter e 3051CA Absolute Pressure Transmitter e 3051CD 3051CG 3051CA 0 3 to 3 inH5O 0 1 inH2O Not Applicable Not Applicable 7 5 to 7 5 mbar 0 25 mbar 1 25 to 25 inH2O 0 5 inH20 25 to 25 inH2O 0 5 inH2O 0 to 30 psia 0 3 psia e 62 2 to 62 2 mbar 1 2 mbar 62 2 to 62 2 mbar 1 2 mbar 0 to 2 1 bar 20 7 mbar 2 250 to 250 inH20 2 5 inH2O 250 to 250 inH2O 2 5 inH2O 0 to 150 psia 1 5 psia e e e 623 to 623 mbar 6 2 mbar 623 to 623 mbar 6 2 mbar 0 to 10 3 bar 0 1 bar 3 1000 to 1000 inH2O 10 inH5O 407 to 1000inH5O 10in H20 0 to 800 psia 8 psia 2
8. 10 of span Stability 0 2 of URL for 1 year Rosemount 3051L Liquid Level Reference Accuracy 0 075 of span Rosemount 3051H High Process Temperature Reference Accuracy 0 075 of span Stability 0 1 of URL for 12 months for Ranges 2 and 3 0 2 of URL for 12 months for Ranges 4 and 5 DETAILED PERFORMANCE SPECIFICATIONS For zero based spans reference conditions silicone oil fill SST materials Coplanar flange 3051C or 1 2 in 18 NPT 3051T process connections digital trim values set to equal range points Reference Accuracy Stated reference accuracy includes hysteresis terminal based linearity and repeatability Rosemount 3051CD 3051CG Range 0 CD 0 10 of span For spans less than 2 1 accuracy 0 05 of URL Range 1 0 10 of span For spans less than 15 1 accuracy Span 0 025 0 005 of Span Ranges 2 5 0 065 of span For spans less than 10 1 accuracy Span 0 015 0 005 J of Span Ranges 2 4 High Accuracy Option P8 0 04 of span For spans less than 5 1 accuracy Span 0 015 0 005 J of Span 1 For FOUNDATION fieldbus transmitters use calibrated range in place of span Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051CA Ranges 1 4 0 065 of span For spans less than 10 1 accuracy Span 0 0075 of Span Ranges 2 4 High Accuracy Option P8 0 04 of span For spans less than 5 1 accuracy Span
9. 5 to 2 5 bar 25 mbar 1 01 to 2 5 bar 25 mbar 0 to 55 2 bar 0 55 bar 4 300 to 300 psi 3 psi 14 7 to 300 psi 3 psi 0 to 4000 psia 40 psia 20 7 to 20 7 bar 0 2 bar 71 01 to 20 7 bar 0 2 bar 0 to 275 8 bar 2 8 bar 5 2000 to 2000 psi 20 psi 14 7 to 2000 psig 20 psi Not Applicable 137 9 to 137 9 bar 1 4 bar 1 01 to 137 9 bar 1 4 bar Code Output 03D CG CA A 4 20 mA with Digital Signal Based on HART Protocol M9 Low Power 1 5 V dc with Digital Signal Based on HART Protocol See Option C2 for 0 8 3 2 V dc x F FOUNDATION fieldbus W Profibus PA OF ore Materials of Construction 6d B CG CA Process Flange Type Flange Material Drain Vent 2 Coplanar SST SST 3 Coplanar Alloy C Hastelloy C276 4 Coplanar Monel Monel e 5 Coplanar Plated CS SST 70 Coplanar SST Hastelloy C276 e e e a Coplanar Plated CS Hastelloy C276 0 Alternate Flange See Options on page 25 Code Isolating Diaphragm CD CG CA i 316L SST e 2 3 4 Hastelloy C276 4 Monel 5 Tantalum Available on 3051CD and CG Ranges 2 5 only Not available on 3051CA e e 6 Gold plated Monel Use in combination with O ring Option Code B e e e 7 Gold plated SST A Glass filled PTFE B Graphite filled PTFE iere Fill Fluid CD CG CA 1 Silicone e E 2 Inert fill Halocarbon e e 24 Product Data Sheet 00813 0100 4001 Rev FA August 200
10. Code PlantWeb Functionality A01 Regulatory control suite PID arith signal char integ etc requires FOUNDATION fieldbus D01 Diagnostics suite Plugged Impulse Line and SPM diagnostics requires FOUNDATION fieldbus Code Integral Mount Primary Elements Optional HD HG S4 Factory Assembly to Rosemount Primary Element Diamond Il Annubar Rosemount 1195 Integral Orifice With the primary element installed the maximum operating pressure will equal the lesser of either the transmitter or the primary element Option is available for factory assembly to range 1 4 transmitters only Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 TABLE 14 3051H Pressure Transmitter for High Temperature Processes Not Applicable Applicable Code Mounting Bracket Options HD HG B5 Universal Mounting Bracket for 2 in Pipe or Panel Mount CS Bolts z B6 Universal Mounting Bracket for 2 in Pipe or Panel Mount SST Bolts gt Code Hazardous Locations Certification Options E5 FM Explosion proof Approval I5 FM Non incendive and Intrinsic Safety Approval K5 FM Explosion proof and Intrinsic Safety Approval I1 ATEX Intrinsic Safety and Dust Certification N10 ATEX Type N and Dust Certification E8 ATEX Flame proof and Dust Certification E40 JIS Flame proof Certification C6 CSA Explosion proof and Intrinsic Safety Approval Ke CSA and ATEX Explosion proof and Intrinsic Safety Approval
11. J1 Local Zero Adjustment Only J3 No Local Zero or Span Adjustment Transient Protection T1 Integral Transient Protection Terminal Block Integral transient protection terminal block Meets IEEE Standard 587 Category B 1 kV crest 10 x 1 000 microseconds 3 kV crest 8 x 20 microseconds 6 kV crest 1 2 x 50 microseconds Meets IEEE Standard 472 Surge Withstand Capability SWC 2 5 kV crest 1 MHz wave form Applicable standards IEC 801 4 801 5 Bolts for Flanges and Adapters Options permit bolts for flanges and adapters to be obtained in various materials e Standard material is plated carbon steel per ASTM A449 Type 1 L4 Austenitic 316 Stainless Steel Bolts L5 ASTM A 193 Grade B7M Bolts L6 Monel Bolts 2 Not applicable to fieldbus Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 Rosemount 3051C Coplanar Flange and 3051T Bracket Option B4 Bracket for 2 in Pipe or Panel Mounting Shipping Weights TABLE 15 Transmitter Weights without Options Transmitter Add Weight In Ib kg e For use with the standard Coplanar flange configuration 3051C 6 0 2 7 Bracket for mounting of transmitter on 2 in pipe or panel 3051L Table 16 on page 37 e Stainless steel construction with stainless steel bolts 3051H 13 6 6 2 3051T 3 0 1 4 Rosemount 3051H Bracket Options B5 Bracket for 2 in Pipe or Panel Mounting For use with the 3051H Pressure Transmitter for high process temperatures
12. Safety Approvals combination of K5 and C6 SAA Flame proof and Intrinsic Safety Approvals combination of I7 N7 and E7 ATEX Flame proof and Intrinsic Safety Approvals combination of 11 and E8 CSA FM and ATEX Explosion proof and Intrinsic Safety Approval combination of K5 C6 11 and E8 SAA Intrinsic Safety Certification SAA Flame proof Certification SAA Type N Certification ATEX Intrinsic Safety for FISCO for FOUNDATION fieldbus protocol only Bolt for Flange and Adapters Optional ASTM A 193 Grade B7M Bolts Meter Options LCD display for Aluminum Housing Available with Housing codes A B C and D only LCD display for SST Housing Available with Housing codes J K L and M only Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 TABLE 13 3051L Flange Mounted Liquid Level Transmitter Code Q4 Q8 D8 v56 Code F1 F2 F3 F4 6 F9 FO Other Options Calibration Data Sheet Material Traceability Certification per EN 10204 3 1 B Available with the diaphragm upper housing Coplanar flange adapter sensor module housing lower housing flushing connection and extension Calibration certification and tamper evident seal Local Zero Adjustment Only No Local Zero or Span Adjustment Transient Protection Terminal Block Custom Software Configuration Completed CDS 00806 0100 4001 required with order 0 8 3 2 V dc Output with Digital Signal Based on HART Protocol Available wit
13. Seal All Welded System Direct Mount Connection Type e e S9 Two Diaphragm Seals All Welded System One Direct Mount and One Capillary Connection Type e 25 Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 TABLE 11 3051C Differential Gage and Absolute Pressure Transmitters Not Applicable X Applicable Code Mounting Bracket Options CD CG CA B4 Coplanar Flange Bracket for 2 in Pipe or Panel Mounting all SST B1 Traditional Flange Bracket for 2 in Pipe Mounting CS Bolts B2 Traditional Flange Bracket for Panel Mounting CS Bolts B3 Traditional Flange Flat Bracket for 2 in Pipe Mounting CS Bolts B7 B1 Bracket with Series 300 SST Bolts e e e B8 B2 Bracket with Series 300 SST Bolts e B9 B3 Bracket with Series 300 SST Bolts e e e BA SST B1 Bracket with Series 300 SST Bolts e e e BC SST B3 Bracket with Series 300 SST Bolts e e e Code Hazardous Locations Certification Options E5 FM Explosionproof Approval I5 FM Non incendive and Intrinsic Safety Approval K5 FM Explosionproof and Intrinsic Safety Approval I ATEX Intrinsic Safety and Dust Certification N19 ATEX Type N and Dust Certification E8 ATEX Flame proof and Dust Certification E49 JIS Flame proof Certification l4 JIS Intrinsic Safety Certification Only available with HART Option Code A d C50 Measurement Canada Accuracy Approval Limited availability d
14. less than 2 0 seconds 10 0 s for Profibus protocol after power is applied to the transmitter Volumetric Displacement Less than 0 005 in 0 08 cm Damping Analog output response to a step input change is user selectable from 0 to 36 seconds for one time constant This software damping is in addition to sensor module response time Rosemount 3051 PHYSICAL SPECIFICATIONS Electrical Connections 12 14 NPT PG 13 5 G1 2 and M20 x 1 5 CM20 conduit HART interface connections fixed to terminal block Process Connections All Models except 3051L and 3051T 114 18 NPT on 21 s in centers 1 2 14 NPT on 2 2 s or 21 4 in centers Rosemount 3051L High pressure side 2 3 or 4 in ASME B 16 5 ANSI Class 150 300 or 600 flange 50 80 or 100 mm PN 40 or 10 16 flange Low pressure side 4 18 NPT on flange 2 14 NPT on adapter Rosemount 3051T 1 2 14 NPT female A DIN 16288 Male available in SST for Range 1 4 transmitters only or Autoclave type F 250 C Pressure relieved 936 18 gland thread 1 4 OD high pressure tube 60 cone available in SST for Range 5 transmitters only Process Wetted Parts Drain Vent Valves 316 SST Hastelloy C276 or Monel material Monel not available with 3051L or 3051H Process Flanges and Adapters Plated carbon steel SST cast CF 8M cast version of 316 SST material per ASTM A743 C Type cast alloy CW12MW or Monel cast alloy M30C Wetted O rings Glass filled PTFE or Graphi
15. line pressures from 0 to 2000 psi 0 to 13 7 MPa For line pressures above 2000 psi 13 7 MPa see user manual Rosemount publication number 00809 0100 4001 Range 0 0 125 of URL 100 psi 6 89 bar Range 1 0 25 of URL Span Error Range 2 3 0 1 of reading Range 0 0 15 of reading 100 psi 6 89 bar Range 1 0 4 of reading Rosemount 3051HD Zero Error can be calibrated out at line pressure 0 1 of URL for line pressures from 0 to 2000 psi 0 to 13 7 MPa For line pressures above 2000 psi 13 7 MPa see user manual Rosemount publication number 00809 0100 4001 Span Error 0 1 of reading Rosemount 3051 Dynamic Performance 4 20mA HART Fieldbus protocol protocol Total Response Time T T 3051C Ranges 2 5 100 ms 152 ms Range 1 255 ms 307 ms Range 0 700 ms 752 ms 3051T 100 ms 152 ms 3051H L Consult factory Consult factory Dead Time Td 45 ms 97 ms nominal Update Rate 22 times per 22 times per second second 1 Dead time and update rate apply to all models and ranges analog output only 2 Nominal total response time at 75 F 24 C reference conditions 3 Transmitter fieldbus output only segment macro cycle not included FIGURE 1 Typical HART Transmitter Response Time Transmitter 4 20 mA Output vs Time Pressure Released Ty Dead Time Ta Tc Te Time Constant Response Time T4 T 63 296 of Total Step Change 3051 3051 17A Mount
16. 0 04 accuracy Five year installed stability of 0 125 Calibrated spans from 0 3 to 10000 psi 10 3 mbar to 689 bar Multiple process connections available e 316L SST and Hastelloy C276 process isolators Rosemount 3051L Liquid Level See ordering information on page 30 SO A g ROSEMOUNT N sy ars e Performance up to 0 075 accuracy with 100 1 turndown e Flush 2 4 and 6 in extended diaphragms e Multiple fill fluids available e 316L SST Hastelloy C276 or Tantalum wetted materials Rosemount 3051 Product Data Sheet 00813 0100 4001 Rev FA August 2004 Specifications This product data sheet covers both HART and fieldbus protocols unless specified PERFORMANCE SPECIFICATIONS Total Performance is based on combined errors of reference accuracy ambient temperature effect and static pressure effect Rosemount 3051C Ranges 2 5 Rosemount 3051T Ranges 1 4 Reference Accuracy 0 065 of span 0 04 of span High Accuracy Option Total Performance 0 15 of span for 50 F 28 C temperature changes up to 1000 psi 6 9 MPa line pressure CD only from 1 1 to 5 1 rangedown Stability 0 125 of URL for 5 years for 50 F 28 C temperature changes and up to 1000 psi 6 9 MPa line pressure Dynamic Performance Total Response Time T HART output 100 ms Fieldbus and Profibus output 152 ms Rosemount 3051CD Low Draft Range Ranges 0 1 Reference Accuracy 0
17. 0 46 When using a HART communicator 5 adjustment is allowed on the sensor limit to allow for unit conversions 3051C Absolute Pressure Transmitter Range Limits Range 1 Span Range 2 Span Range 3 Span Range 4 Span min max min max min max min max inH5O 8 30397 831 889 41 5198 4151 98 221 439 22143 9 1107 2 110720 inHg 0 61081 61 0807 3 05403 305 403 16 2882 1628 82 81 441 8144 098 ftH5O0 0 69199 69 3241 3 45998 345 998 18 4533 1845 33 92 2663 9226 63 mmH5O 211 10 21130 6 35308 635 308 5634 66 563466 28146 1 2814613 mmHg 15 5145 1551 45 1055 47 105547 413 72 41372 2068 6 206860 0 psi 0 3 30 15 150 8 800 40 4000 bar 0 02068 2 06843 0 10342 10 342 0 55158 55 1581 2 75791 275 7905 mbar 20 6843 2068 43 103 421 10342 1 551 581 55158 1 2757 91 275790 5 g cm 21 0921 2109 21 105 27 105 27 561 459 56145 9 2807 31 280730 6 kg cm 0 02109 2 10921 0 10546 10 546 0 56246 56 2456 2 81228 281 228 Pa 2068 43 206843 10342 1 1034210 55158 1 5515811 275791 27579054 kPa 2 06843 206 843 10 3421 1034 21 55 1581 5515 81 275 791 27579 05 torr 15 5145 1551 45 77 5726 7757 26 413 721 413721 2068 6 206859 7 atm 0 02041 2 04138 0 10207 10 207 0 54437 54 4368 2 72184 272 1841 When using a HART communicator 5 adjustment is allowed on the sensor limit to allow for unit conversions 41 Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 Rosemount Annubar ProPlate and the Rosemount logotype are registered trademarks of Rosemount Inc PlantWeb
18. 0100 4001 Rev FA August 2004 Rosemount 3051 LCD display CONFIGURATION Software Adjustable M5 or M6 option must be specified in model number Meter Display Type a Eng Units only Alternate Eng Units amp of Range x m of Range only Alternate Eng Units amp Custom Display L Custom Display only Alternate of Range amp Custom Display 9 Custom Display Configuration must be filled out if Custom Display is selected as meter type Decimal Point Position fixed X Xa X X X indicate decimal point location Enter Lower Range Value Decimal point must be in the same position as specified above circle sign ld J GLI GL IAL n 000 00 x Enter Upper Range Value Decimal point must be in the same position as specified above circle sign ld lal hb lel a 100 00 x Custom Units spaces consume A Z 0 9 96 blank L RNGE Custom Display Transfer Function Independent of Analog Output m Linear Square Root HARDWARE SELECTABLE INFORMATION Alarm Option m High Transmitter Security L Off Note Specify C4 Option in model structure when ordering NAMUR compliant alarm and saturation limits 5 SIGNAL SELECTION Software Selectable E 4 20 mA with simultaneous digital signal based on HART protocol Burst mode of HART digital process variable 4 Burst mode output options L Prim
19. 1TG 3051TA 1 14 7 to 30 psi 0 3 psi 1 01 to 2 1 bar 20 7 mbar 0 to 30 psia 0 3 psia 0 to 2 1 bar 20 7 mbar 2 14 7 to 150 psi 1 5 psi 1 01 to 10 3 bar 103 4 mbar 0 to 150 psia 1 5 psia 0 to 10 3 bar 103 4 mbar 3 14 7 to 800 psi 8 psi 1 01 to 55 2 bar 0 55 bar O to 800 psia 8 psia 0 to 55 2 bar 0 55 bar 4 14 7 to 4000 psi 40 psi 1 01 to 275 8 bar 2 8 bar 0 to 4000 psia 40 psia 0 to 275 8 bar 2 8 bar 5 14 7 to 10000 psi 2000 psi 1 01 to 689 5 bar 138 bar O0 to 10000 psia 2000 psia 0 to 689 5 bar 138 bar lerere Output A 4 20 mA with Digital Signal Based on HART Protocol M Low Power 1 5 V dc with Digital Signal Based on HART Protocol See Option Code C2 for 0 8 3 2 V dc Output Not available with hazardous certification Option Codes 11 N1 E4 K6 or K8 F FOUNDATION fieldbus W Profibus PA Code Process Connection Style 2B 2 14 NPT Female 2C G A DIN 16288 Male Available in SST for Range 1 4 only 2F Coned and Threaded Compatible with Autoclave Type F 250 C Only available in SST for Range 5 Code Isolating Diaphragm Process Connection Wetted Parts Material 2 316L SST 316L SST 3 Hastelloy C276 Hastelloy C276 Code Fill Fluid Silicone Inert Fluorinert FC 43 Code Housing Material Conduit Entry Size A Polyurethane covered Aluminum 72 14 NPT B Polyurethane covered Aluminum M20 x 1 5 CM20 C Polyurethane covered Aluminum PG 13 5 D Polyurethane covered Aluminum
20. 2 5 only v5 External Ground Screw Assembly Typical Model Number 3051CD 2 A 2 2 A 1 A B4 1 3051CG lower range limit varies with atmospheric pressure 2 3051CD0 is available only with Output Code A Process Flange Code 0 Alternate Flange H2 H7 HJ or HK Isolating Diaphragm Code 2 O ring Code A and Bolting Option L4 3 Not available with hazardous locations certification Options Codes 11 N1 E4 K6 and K8 4 Materials of Construction comply with recommendations per NACE MR0175 ISO 15156 for sour oil field production environments Environmental limits apply to certain materials Consult latest standard for details Selected materials also conform to NACE MRO0103 for sour refining environments 5 Not available with Low Power code M 6 Not available with Fieldbus output code F or Profibus output code W 7 Local zero and span adjustments are standard unless Option Code J1 or J3 is specified 8 NAMUR Compliant operation is pre set at the factory and cannot be changed to standard operation in the field 9 The V5 option is not needed with the T1 option external ground screw assembly is included with the T1 option 27 Rosemount 3051 Product Data Sheet 00813 0100 4001 Rev FA August 2004 TABLE 12 3051T Gage and Absolute Pressure Transmitter Model 3051T Pressure Transmitter Transmitter Type Code Pressure Type G Gage A Absolute lerere Pressure Ranges Range Min Span 305
21. 2 Groups A B C and D Temperature Code T4 Ta 40 C T3 Ta 85 C Enclosure Type 4X For input parameters see control drawing 03031 1019 Canadian Standards Association CSA N1 E6 C6 Explosion Proof for Class I Division 1 Groups B C and D Dust Ignition Proof for Class Il and Class III Division 1 Groups E F and G Suitable for Class Division 2 Groups A B C and D for indoor and outdoor hazardous locations Enclosure type 4X factory sealed Explosion Proof and intrinsically safe approval Intrinsically safe for Class I Division 1 Groups A B C and D when connected in accordance with Rosemount drawings 03031 1024 Temperature Code T3C Explosion Proof for Class Division 1 Groups B C and D E8 Dust Ignition Proof for Class Il and Class III Division 1 Groups E F and G Suitable for Class I Division 2 Groups A B C and D hazardous locations Enclosure type 4X factory sealed For input parameters see control drawing 03031 1024 European Certifications I1 14 ATEX Intrinsic Safety and Dust Certification No BAS 98BATEX1355X II 1 GD EEx ia IIC T4 Tamp 60 to 60 C Dust Rating T70 C Tamp 20 to 40 C IP66 ce 1180 TABLE 7 Input Parameters U 30V l 300 mA P 1 3W C 0 uF Special Conditions for Safe Use X The device is not capable of withstanding the 500V insulation test required by Clause 6 4 12 of EN50020 1994 This must be taken into
22. 227 23 622 723 62160 6 2490 89 249089 20684 3 2068430 137895 13789500 kPa 0 12545 6 2272 0 62272 62 2723 2 49089 249 089 20 6843 2068 43 137 895 13789 5 torr 0 93416 46 7082 4 67082 467 082 18 6833 1868 33 155 145 15514 5 1034 3 103430 atm 0 00123 0 06146 0 00615 0 61460 0 02458 2 458 0 20414 20 4138 1 36092 136 092 When using a HART communicator 5 adjustment is allowed on the sensor limit to allow for unit conversions min max min max min max min max inH2O 2 5 250 10 1000 83 040 8304 553 60 55360 inHg 0 18389 18 389 0 73559 73 559 6 1081 610 81 40 720 4072 04 ftH O 0 20833 20 8333 0 83333 83 3333 6 9198 691 997 46 13 4613 31 mmH 0 63 553 6355 254 25421 2110 95 211095 14073 1407301 mmHg 4 67082 467 082 18 6833 1868 33 155 145 15514 5 1034 3 103430 psi 0 0902 9 03183 0 36127 36 127 3 300 20 2000 bar 0 00623 0 62272 0 02491 2 491 0 20684 20 6843 1 37895 137 895 mbar 6 22723 622 723 24 9089 2490 89 206 843 20684 3 1378 95 137895 g cm 6 33875 633 875 25 355 2535 45 210 547 21054 7 1406 14 140614 kg cm 0 00635 0 635 0 0254 2 54 0 21092 21 0921 1 40614 140 614 Pa 622 723 62160 6 2490 89 249089 20684 3 2068430 137895 13789500 kPa 0 62272 62 2723 2 49089 249 089 20 6843 2068 43 137 895 13789 5 torr 4 67082 467 082 18 6833 1868 33 155 145 15514 5 1034 3 103430 atm 0 00615 0 61460 0 02458 2 458 0 20414 20 4138 1 36092 136 092 When using a HART communicator 5 adjustment is allowed on the sensor limit to allow for unit conversions 40 3051L 3051H
23. 3051 Pressure Transmitters meet all of the requirements of IECEN61326 and NAMUR NE 21 Ordinary Location Certification for Factory Mutual As standard the transmitter has been examined and tested to determine that the design meets basic electrical mechanical and fire protection requirements by FM a nationally recognized testing laboratory NRTL as accredited by the Federal Occupational Safety and Health Administration OSHA HART PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion Proof for Class I Division 1 Groups B C and D Dust Ignition Proof for Class II Division 1 Groups E F and G Dust Ignition Proof for Class lll Division 1 T5 Ta 85 C Factory Sealed Enclosure Type 4X 15 Intrinsically Safe for use in Class Division 1 Groups A B C and D Class II Division 1 Groups E F and G Class Ill Division 1 when connected per Rosemount drawing 03031 1019 Non incendive for Class Division 2 Groups A B C and D Temperature Code T4 Ta 40 C T3 Ta 85 C Enclosure Type 4X For input parameters see control drawing 03031 1019 Canadian Standards Association CSA E6 Explosion Proof for Class I Division 1 Groups B C and D Dust Ignition Proof for Class Il and Class III Division 1 Groups E F and G Suitable for Class Division 2 Groups A B C and D for indoor and outdoor hazardous locations Enclosure type 4X factory sealed C6 E
24. 3051H process flange is 10000 psig 69 MPa Burst pressure for the 3051T is Ranges 1 4 11000 psi 75 8 MPa Range 5 26000 psig 179 MPa Failure Mode Alarm Output Code A If self diagnostics detect a gross transmitter failure the analog signal will be driven either below 3 75 mA or to 22 mA to alert the user NAMUR compliant values x 3 6 mA and 22 5 mA are available option code C4 High or low alarm signal is user selectable by internal jumper Output Code M If self diagnostics detect a gross transmitter failure the analog signal will be driven either below 0 94 V or above 5 4 V to alert the user below 0 75 V or above 4 4 V for Option C2 High or low alarm signal is user selectable by internal jumper Output Code F and W If self diagnostics detect a gross transmitter failure that information gets passed as a status along with the process variable Temperature Limits Ambient 40 to 185 F 40 to 85 C With integral meter 4 to 175 F 20 to 80 C Storage 50 to 230 F 46 to 110 C With integral meter 40 to 185 F 40 to 85 C Process At atmospheric pressures and above See Table 4 Rosemount 3051 TABLE 4 3051 Process Temperature Limits 3051CD 3051CG 3051CA Silicone Fill Sensor with Coplanar Flange 40 to 250 F 40 to 121 C with Traditional Flange 40 to 300 F 40 to 149 c 2 9 with Level Flange 40 to 300 F 40 to 149 C 2 2 with 305 In
25. 3051SFA 3095MFA and 485 The state of the art fifth generation Rosemount 485 Annubar combined with the 3051S or 3095MV MultiVariable transmitter creates an accurate repeatable and dependable insertion type flowmeter Compact Orifice Flowmeter Series Rosemount 3051SFC 3095MFC and 405 Compact Orifice Flowmeters can be installed between existing flanges up to a Class 600 PN100 rating In tight fit applications a conditioning orifice plate version is available requiring only two diameters of straight run upstream ProPlate Flowmeter Series Rosemount ProPlate Mass ProPlate and 1195 These integral orifice flowmeters eliminate the inaccuracies that become more pronounced in small orifice line installations The completely assembled ready to install flowmeters reduce cost and simplify installation Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 Product Offering Rosemount 3051C Differential Gage and Absolute See ordering information on page 24 Performance up to 0 04 accuracy Five year installed stability of 0 125 Coplanar platform enables integrated manifold primary element and diaphragm seal solutions Calibrated spans ranges from 0 1 inH5O to 4000 psi 0 25 mbar to 276 bar 316L SST Hastelloy C276 Mone Tantalum Gold plated Monel or Gold plated 316L SST process isolators Rosemount 3051T Gage and Absolute See ordering information on page 28 Performance up to
26. 4 Rosemount 3051 TABLE 11 3051C Differential Gage and Absolute Pressure Transmitters Not Applicable Applicable Code Housing Material Conduit Entry Size A Polyurethane covered Aluminum 72 14 NPT e e e B Polyurethane covered Aluminum M20 x 1 5 CM20 C Polyurethane covered Aluminum PG 13 5 e e e D Polyurethane covered Aluminum GY J SST 72 14 NPT e e K SST M20 x 1 5 CM20 e L SST PG 13 5 e e e M SST G Code PlantWeb Functionality A01 Regulatory control suite PID arith signal char integ etc requires FOUNDATION fieldbus D01 Diagnostics suite Plugged Impulse Line and SPM diagnostics requires FOUNDATION fieldbus e e e Code Alternate Flange Options Requires Materials of Construction Code 0 H2 Traditional Flange 316 SST SST Drain Vent H3 Traditional Flange Alloy C Hastelloy C276 Drain Vent H4 Traditional Flange Monel Monel Drain Vent H7 Traditional Flange 316 SST Hastelloy C276 Drain Vent HJ DIN Compliant Traditional Flange SST 16 in Adapter Manifold Bolting e e e HK DIN Compliant Traditional Flange SST 10 mm Adapter Manifold Bolting HL DIN Compliant Traditional Flange SST 12mm Adapter Manifold Bolting Not available on 3051CD0 e e e FA Level Flange SST 2 in ANSI Class 150 Vertical Mount FB Level Flange SST 2 in ANSI Class 300 Vertical Mount e e e FC Level Flange SST 3 in ANSI Class 150 Vertical M
27. 5 Tamb 80 C DIP A21 T6 Tag 40 C DIP A21 T5 Tag 80 C IP65 Special Conditions for Safe Use X It is a condition of safe use for transmitter enclosures having cable entry thread other than metric conduit thread that the equipment be utilized with an appropriate certified thread adaptor SAA Type n Non sparking Certification No AUS Ex 1249X Ex n IIC T4 Tamb 70 C Ex n IIC T5 Tamp 40 C IP66 Special Conditions for Safe Use X Where the equipment is installed such that there is an unused conduit entry it must be sealed with a suitable blanking plug to maintain the IP40 degree of protection Any blanking plug used with the equipment shall be of a type which requires the use of a tool to effect its removal Voltage source shall not exceed 60V ac or 75V dc Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified Once a device labeled with multiple approval types is installed it should not be reinstalled using any other approval types Permanently mark the approval label to distinguish it from unused approval types K5 KB KD K6 K8 K7 E5 and I5 combination K5 and C6 combination K5 C6 I1 and E8 combination C6 I1 and E8 combination E8 and 11 combination E7 I7 and N7 combination 15 Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 Dimensional Drawings 3051 Exploded View Certification Lab
28. 8 For use with the traditional flange option J K L M Stainless Steel Housing C L H P 3 1 1 4 Bracket for vertical mounting of transmitter on 2 in pipe M5 LCD display for Aluminum Housing 0 5 0 2 Carbon steel construction with carbon M6 LCD display for SST Housing 1 25 0 6 B4 SST Mounting Bracket for Coplanar Flange 0 5 B1B2B3 Mounting Bracket for Traditional Flange 1 0 steel bolts 1 0 2 3 B7 B8 B9 Mounting Bracket for Traditional Flange 2 3 1 0 2 5 Coated with polyurethane paint B7 B1 Bracket with SST Bolts Same bracket as the B1 option with Series 300 stainless steel BA BC SST Bracket for Traditional Flange 1 0 bolts B5 B6 Mounting Bracket for 3051H 2 9 1 3 B8 B2 Bracket with SST Bolts H2 Traditional Flange 2 4 1 1 Same bracket as the B2 option with Series 300 stainless steel H3 Traditional Flange 2 7 1 2 bolts H4 Traditional Flange 2 6 1 2 B9 B3 Bracket with SST Bolts H7 Traditional Flange 2 5 1 1 e Same bracket as the B3 option with Series 300 stainless steel FC Level Flange 3 in 150 10 8 4 9 bolts FD Level Flange 3 in 300 14 3 6 5 BA Stainless Steel B1 Bracket with SST Bolts FA Level Flange 2 in 150 10 7 4 8 B1 bracket in stainless steel with Series 300 stainless steel FB Level Flange 2 in 300 14 0 6 3 bolts FP DIN Level Flange SST DN 50 PN 40 8 3 3 8 BC Stainless Steel B3 Bracket with SST Bolts FQ DIN Level Flange SST DN 80 PN 40 13 7 6 2 e B3 bracket in stain
29. 9 bar 34 5 mbar abs 137 9 bar 34 5 mbar abs 1 Range 0 only available with 3051CD Range 1 only available with 3051CD or 3051CG TABLE 2 Range and Sensor Limits 3051CA 3051T Range and Sensor Limits Range and Sensor Limits Minimum Upper Lower Minimum Upper Lower Lower Span URL LRL Span URL LRL LRL Gage 1 0 3 psia 30 psia 0 psia 1 0 3 psi 30 psi 0 psia 14 7 psig 20 6 mbar 2 07 bar 0 bar 20 6 mbar 2 07 bar 0 bar 1 01 bar 2 1 5 psia 150 psia 0 psia 2 1 5 psi 150 psi 0 psia 14 7 psig 0 103 bar 10 3 bar 0 bar 0 103 bar 10 3 bar 0 bar 1 01 bar 3 8 psia 800 psia 0 psia 3 8 psi 800 psi 0 psia 14 7 psig 0 55 bar 55 2 bar 0 bar 0 55 bar 55 2 bar 0 bar 1 01 bar 4 40 psia 4000 psia 0 psia 4 40 psi 4000 psi 0 psia 14 7 psig 2 76 bar 275 8 bar 0 bar 2 76 bar 275 8 bar 0 bar 1 01 bar 5 2000 psi 10000 psi 0 psia 14 7 psig 137 9 bar 689 4 bar 0 bar 1 01 bar 1 Assumes atmospheric pressure of 14 7 psig Rosemount 3051 Zero and Span Adjustment Requirements HART and Low Power Zero and span values can be set anywhere within the range limits stated in Table 1 and Table 2 Span must be greater than or equal to the minimum span stated in Table 1 and Table 2 Service Liquid gas and vapor applications 4 20 mA Output Code A Output Two wire 4 20 mA user selectable for linear or square root output Digital process vari
30. G J SST 72 14 NPT K SST M20 x 1 5 CM20 L SST PG 13 5 M SST G Code PlantWeb Functionality A01 Regulatory control suite PID arith signal char integ etc requires FOUNDATION fieldbus D01 Diagnostics suite Plugged Impulse Line and SPM diagnostics requires FOUNDATION fieldbus Code S5 Assemble to Rosemount 306 Integral Manifold specified separately see the Rosemount 305 and 306 Integral Manifolds PDS document number 00813 0100 4733 Requires 1 2 in process connection code 2B Integral Mount Manifold Optional Code Remote Diaphragm Seals Assemblies Optional S1 One remote diaphragm seal Direct Mount or Capillary Connection Type Requires Process Connection Style code 2B Code Mounting Brackets Optional B4 Bracket for 2 in Pipe or Panel Mounting All SST 28 Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 TABLE 12 3051T Gage and Absolute Pressure Transmitter lerere Hazardous Locations Certifications Optional K5 C5 C6 K6 3 KB K7 ka 3 Kp 9 I7 EA E7 N7 H9 N19 E8 DW IA Ooo FM Explosion proof Approval FM Non incendive and Intrinsic Safety Approval FM Explosion proof and Intrinsic Safety Approval Measurement Canada accuracy approval Limited availability depending on transmitter type and range Contact an Emerson Process Management representative CSA Explosion proof and Intrinsic Safety Approval CSA and ATEX Explosion proof and Intrins
31. Pressure Transmitter Range Limits Range 2 Span Range 3 Span Range 4 Span Range 5 Span Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 3051T Gage and Absolute Pressure Transmitter Range Limits Range 1 Span Range 2 Span Range 3 Span Range 4 Span Range 5 Span min max min max min max min max min max inH5O 8 30397 831 889 41 5198 4159 45 221 439 22143 9 1107 2 110720 55360 2 6 99 inHg 0 61081 61 0807 3 05403 305 403 16 2882 1628 82 81 441 8144 098 4072 04 20360 2 ftH2O 0 69199 69 3241 3 45998 345 998 18 4533 1845 33 92 2663 9226 63 4613 31 23066 6 mmH5O 211 10 21130 1054 60 105460 3 5634 66 563466 28146 1 2814613 1407301 7036507 mmHg 15 5145 1551 45 77 5723 7757 23 413 72 41372 2068 6 206860 0 103430 517151 psi 0 3 30 1 5 150 8 800 40 4000 2000 10000 bar 0 02068 3 06843 0 10342 10 3421 0 55158 55 1581 2 75791 275 7905 137 895 689 476 mbar 20 6843 2068 43 103 421 10342 11 551 581 55158 1 2757 91 275790 5 137895 689476 g cm 21 0921 2109 21 105 461 10546 1 561 459 56145 9 2807 31 280730 6 140614 703067 kg cm 0 02109 2 10921 0 10546 10 5461 0 56246 56 2456 2 81228 281 228 140 614 701 82 Pa 2068 43 206843 10342 1 1034212 55158 1 5515811 275791 27579054 13789500 68947600 kPa 2 06843 206 843 10 3421 1034 21 55 1581 5515 81 275 791 27579 05 13789 5 68947 6 torr 15 5145 1551 45 77 5726 7757 26 413 721 413721 2068 6 206859 7 103430 517151 atm 0 02041 2 04138 0 10207 10 2069 0 54437 54 4368 2 12184 272 1841 136 092 68
32. Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 Rosemount 3051 Pressure Transmitter HART AND FOoUNDATION FIELDBUS PROTOCOLS Best in Class performance 0 0496 High Accuracy option e Industry first five year stability under actual process conditions Unmatched Dynamic Performance Coplanar platform enables integrated pressure flow and level solutions Advanced PlantWeb Functionality CE FOUNDATION Contents Product Offering P pc UOPT page 3 SoDecINCallOllS 44 asc du hoa ee bones EIU PS SS HeSG Age quu SIN Dey PE qe E page 4 Product Certifications aaae page 11 PART AFOLOG DII s tyke each di Aerie ee b eie de ditm quod b de Be HE e ID de o Xr Mek cir dr ir page 11 Fieldbus Protocol 0 0 0 0 0 ccc Inn page 14 Dimensional DrawingS 0 00 eee ees page 16 Ordering Information 2 0 00 eee eee page 24 HART Protocol C1 Option Configuration Data Sheet 0 page 38 ROSEMOUNT woe EMERSON www rosemount com Process Management Rosemount 3051 Product Data Sheet 00813 0100 4001 Rev FA August 2004 Setting the Standard for Pressure Measurement Industry s best total performance a flexible Cop anar platform and guaranteed 5 year stability has made the Rosemount 3051 the standard in pressure measurement Industry s best total performance of 0 15 Total performance is the true
33. ST Silicone Requires Option Code S1 Code O ring Material A Glass filled PTFE 31 Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 TABLE 13 3051L Flange Mounted Liquid Level Transmitter Code SrAcVUNOW SYS Of ete 1 A01 D01 0o S1 0o Housing Material Conduit Entry Size Polyurethane covered Aluminum 72 14 NPT Polyurethane covered Aluminum M20 x 1 5 CM20 Polyurethane covered Aluminum PG 13 5 Polyurethane covered Aluminum G7 SST 72 14 NPT SST M20 x 1 5 CM20 SST PG 13 5 SST G PlantWeb Functionality Regulatory control suite PID arith signal char integ etc requires Foundation fieldbus Diagnostics suite Plugged Impulse Line and SPM diagnostics requires Foundation fieldbus Diaphragm Seal Assemblies Optional One Diaphragm Seal requires low pressure side Option Code 31 capillary connection type Hazardous Locations Certification Options E5 I5 K5 14 0 N1401 E401 Code L5 OF oye M5 M6 FM Explosion proof Approval FM Non incendive and Intrinsic Safety Approval FM Explosion proof and Intrinsic Safety Approval ATEX Intrinsic Safety and Dust Certification ATEX Type N and Dust Certification ATEX Flame proof and Dust Certification JIS Flame proof Certification CSA Explosion proof and Intrinsic Safety Approval CSA and ATEX Explosion proof and Intrinsic Safety Approval combination of C6 and K8 FM and CSA Explosion proof and Intrinsic
34. Tamp 70 C Ex ia IIC T5 Tamp 40 C IP66 When connected per Rosemount drawing 03031 1026 TABLE 6 Input Parameters U 30V l 200 mA l 160 mA output code A with T1 P 0 9W C 0 01 uF C 0 042 pF output code M L 10 uH L 1 05 mH output code A with T1 L 0 75 mH output code M with T1 Special Conditions for Safe Use X The apparatus may only be used with a passive current limited power source Intrinsic Safety application The power source must be such that Po lt Uo lo 4 Modules using transient protection in the terminal assembly T1 transient protection models the apparatus enclosure is to be electrically bonded to the protective earth The conductor used for the connection shall be equivalent to a copper conductor of 4 mm2 minimum cross sectional area Product Data Sheet 00813 0100 4001 Rev FA August 2004 E7 N7 SAA Explosion Proof Flame Proof Certification No AUS Ex 03 1347X Ex d IIC T6 Tag 40 C Ex d IIC T5 Tamb 80 C DIP A21 T6 Tamb 40 C DIP A21 T5 Tamb 80 C IP66 Special Conditions for Safe Use X It is a condition of safe use for transmitter enclosures having cable entry thread other than metric conduit thread that the equipment be utilized with an appropriate certified thread adaptor SAA Type n Non sparking Certification No AUS Ex 1249X Ex n IIC T4 Tamb 70 C Ex n IIC T5 Tamp 40 C IP66 Special Conditio
35. Time 1 nanosecond Peak Surge Current 5000 amps to housing Peak Transient Voltage 100 V dc Loop Impedance 25 ohms Applicable Standards IEC61000 4 4 IEC61000 4 5 NOTE Calibrations at 68 F 20 C per ASME Z210 1 ANSI Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 FUNCTIONAL SPECIFICATIONS Range and Sensor Limits TABLE 1 3051CD 3051CG 3051L and 3051H Range and Sensor Limits Minimum Span Range and Sensor Limits Lower LRL 3051CD Upper 3051C 3051C 3051L 3051L 3051H CG L H URL Differential Gage Differential Gage Differential 0 0 1 inH2O 3 0 inH2O 3 0 inH5O NA NA NA NA NA 0 25 mbar 7 47 mbar 7 47 mbar 1 0 5 inH2O 25 inH O 25 inH2O 25 inH2O NA NA NA NA 1 2 mbar 62 3 mbar 762 3 mbar 762 3 mbar 2 2 5 inH5O 6 2 250 inH O 250 inH2O 250 inH2O 250 inH2O 250 inH2O 250 inH2O 250 inH5O mbar 0 62 bar 0 62 bar 0 62 bar 0 62 bar 0 62 bar 0 62 bar 0 62 bar 3 10 inH20 24 9 1000 inH2O 1000 inH2O 0 5 psia 1000 inH2O 0 5 psia 1000 inH2O 0 5 psia mbar 2 49 bar 2 49 bar 34 5 mbar abs 2 49 bar 34 5 mbar abs 72 49 bar 34 5 mbar abs 4 3 psi 300 psi 300 psi 0 5 psia 300 psi 0 5 psia 300 psi 0 5 psia 0 20 bar 20 6 bar 20 6 bar 34 5 mbar abs 20 6 bar 34 5 mbar abs 20 6 bar 34 5 mbar abs 5 20 psi 2000 psi 2000 psi 0 5 psia NA NA 2000 psi 0 5 psia 1 38 bar 137 9 bar 137
36. able for the sensor module housing and Coplanar or traditional flanges and adapters 3051C and for the sensor module housing and low volume Coplanar flange and adapter 3051C with Option Code S1 Q16 Surface finish certification for sanitary remote seals d i j QP Calibration certification and tamper evident seal f QS Quality Certification for safety J41 7 Local Zero Adjustment Only J3 C No Local Zero or Span Adjustment k T1 Transient Protection Terminal Block e C19 Custom Software Configuration Completed CDS 00806 0100 4001 required with order C2 9 0 8 3 2 V dc Output with Digital Signal Based on HART Protocol Output Code M only C3 Gage Calibration 3051CA4 only c4 6 8 Analog Output Levels Compliant with NAMUR Recommendation NE 43 y f CN O 8 Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Configuration Low s 1 P1 Hydrostatic Testing P2 Cleaning for Special Service P3 Cleaning for lt 1 PPM Chlorine Fluorine P4 Calibrate at line pressure Specify Q48 on order for corresponding certificate x i I DF 1 2 14 NPT flange adapter s Material determined by flange material e e D7 Coplanar Flange Without Drain Vent Ports e e e D8 Ceramic Ball Drain Vents D9 JIS Process Connection RC 74 Flange with RC 75 Flange Adapter e e e P8 0 04 accuracy to 5 1 turndown Range 2 4 P9 4500 psig Static Pressure Limit 3051CD Ranges
37. able superimposed on 4 20 mA signal available to any host that conforms to the HART protocol Power Supply External power supply required Standard transmitter 4 20 mA operates on 10 5 to 55 V dc with no load Load Limitations Maximum loop resistance is determined by the voltage level of the external power supply as described by Max Loop Resistance 43 5 Power Supply Voltage 10 5 Operating Load Ohms 10 5 20 30 40 55 Voltage V dc Communication requires a minimum loop resistance of 250 ohms 1 For CSA approval power supply must not exceed 42 4 V FOUNDATION fieldbus output code F and Profibus output code W Power Supply External power supply required transmitters operate on 9 0 to 32 0 V dc transmitter terminal voltage Current Draw 17 5 mA for all configurations including LCD display option Product Data Sheet 00813 0100 4001 Rev FA August 2004 Low Power Output Code M Output Three wire 1 5 V dc or 0 8 3 2 V dc Option Code C2 user selectable output Also user selectable for linear or square root output configuration Digital process variable superimposed on voltage signal available to any host conforming to the HART protocol Low power transmitter operates on 6 12 V dc with no load Power Consumption 3 0 mA 18 36 mW Minimum Load Impedance 100 KO Vout wiring Indication Optional 5 digit LCD display Overpressure Limits Rosemount 3051CD CG e R
38. account when installing the apparatus Product Data Sheet 00813 0100 4001 Rev FA August 2004 ATEX FISCO Intrinsic Safety Certification No BAS 98BATEX1355X 9 II 1G EEx ia IIC T4 Tamb 60 to 60 C IP66 ce 1180 TABLE 8 Input Parameters U 2 17 5 V l 380 mA Pi 5 32W C lt 5 uF L 10 uH Special Conditions for Safe Use X The device is not capable of withstanding the 500V insulation test required by Clause 6 4 12 of EN50020 1994 This must be taken into account when installing the apparatus ATEX Type n and Dust Certification No BAS 98ATEX3356X 9 II 3 GD EEx nL IIC T5 Tamp 40 to 70 C U 40 Vdc max Dust rating T80 C Tamb 20 to 40 C IP66 Special Conditions for Safe Use X The device is not capable of withstanding the 500V insulation test required by Clause 6 4 12 of EN50020 1994 This must be taken into account when installing the apparatus ATEX Flame Proof and Dust Certification No KEMA OOATEX2013X II 1 2 GD EEx d IIC T6 Tamp 50 to 65 C EEx d IIC T5 Tamp 50 to 80 C Dust rating T90 C IP66 ce 1180 Vmax 55 V dc Special Conditions for Safe Use X This device contains a thin wall diaphragm Installation maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected The manufacturer s instructions for installation and maintenance shall be followed in detail to assure safety d
39. ange 0 750 psi 51 7 bar e Range 1 2000 psig 137 9 bar e Ranges 2 5 3626 psig 250 bar 4500 psig 310 3 bar for option code P9 Rosemount 3051CA e Range 1 120 psia 8 27 bar e Range 2 300 psia 20 7 bar e Range 3 1600 psia 110 3 bar e Range 4 6000 psia 413 7 bar Rosemount 3051H All Ranges 3626 psig 25 MPa Rosemount 3051TG TA Range 1 750 psi 51 7 bar Range 2 1500 psi 103 4 bar Range 3 1600 psi 110 3 bar Range 4 6000 psi 413 7 bar e Range 5 15000 psi 1034 2 bar For 3051L or Level Flange Option Codes FA FB FC FD FP and FQ limit is O psia to the flange rating or sensor rating whichever is lower TABLE 3 3051L and Level Flange Rating Limits Standard Type CS Rating SST Rating ANSI ASME Class 150 285 psig 275 psig ANSI ASME Class 300 740 psig 720 psig ANSI ASME Class 600 1480 psig 1440 psig At 100 F 38 C the rating decreases with increasing temperature DIN PN 10 40 40 bar 40 bar DIN PN 10 16 16 bar 16 bar DIN PN 25 40 40 bar 40 bar At 248 F 120 C the rating decreases with increasing temperature Product Data Sheet 00813 0100 4001 Rev FA August 2004 Static Pressure Limit Rosemount 3051CD Only Operates within specifications between static line pressures of 0 5 psia and 3626 psig 4500 psig for Option Code P9 Range 0 0 5 psia and 750 psig Range 1 0 5 psia and 2000 psig Burst Pressure Limits Burst pressure on Coplanar traditional or
40. ary variable in engineering units E Primary variable in percent of range L All dynamic variables in engineering units and the primary variable mA value Multidrop Communication Choose transmitter address 1 15 4 C1 option required for configuration of this parameter 5 Not available with low power output 6 This option fixes the transmitter analog output at 4mA 7 Default address is 1 if multidrop communication is selected 39 Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 3051C Differential Gage Pressure Transmitter Range Limits Range 1 Span Range 2 Span Range 3 Span Range 4 Span Range 5 Span min max min max min max min max inH5O 0 5 25 2 5 250 10 1000 83 040 8304 553 60 55360 inHg 0 03678 1 8389 0 18389 18 389 0 73559 73 559 6 1081 610 81 40 720 4072 04 ftH2O 0 04167 2 08333 0 20833 20 8333 0 83333 83 3333 6 9198 691 997 46 13 4613 31 mmH 0 12 7 635 5 63 553 6355 254 25421 2110 95 211095 14073 1407301 mmHg 0 93416 46 7082 4 67082 467 082 18 6833 1868 33 155 145 15514 5 1034 3 103430 psi 0 01806 0 903 0 0902 9 03183 0 36127 36 127 3 300 20 2000 bar 0 00125 0 06227 0 00623 0 62272 0 02491 2 491 0 20684 20 6843 1 37895 137 895 mbar 1 2454 62 2723 6 22723 622 723 24 9089 2490 89 206 843 20684 3 1378 95 137895 g cm 1 26775 63 3875 6 33875 633 875 25 355 2535 45 210 547 21054 7 1406 14 140614 kg cm 0 00127 0 0635 0 00635 0 635 0 0254 2 54 0 21092 21 0921 1 40614 140 614 Pa 124 545 6
41. atus is not capable of withstanding a 500V r m s test to case This must be taken into account on any installation in which it is used for example by assuring that the supply to the apparatus is galvanically isolated ATEX Flame Proof and Dust Certification No KEMA 00ATEX2013X II 1 2 GD EEx d IIC T6 50 lt T4 x 65 C EEx d IIC T5 50 lt T4 lt 80 C Dust rating T90 C IP66 ce 1180 Vmax 55 V dc Special Conditions for Safe Use X This device contains a thin wall diaphragm Installation maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected The manufacturer s instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime Product Data Sheet 00813 0100 4001 Rev FA August 2004 Japanese Certifications E4 JIS Flame Proof Ex d IIC T6 Certificate Description C15850 3051C D 1 4 20 mA HART no meter C15851 3051C D 1 4 20 mA HART with meter C15854 3051T G 1 4 20 mA HART SST Silicon no meter C15855 3051T G 1 4 20 mA HART Hastelloy C276 Silicon no meter C15856 3051T G 1 4 20 mA HART SST Silicon with meter C15857 3051T G 1 4 20 mA HART Hastelloy C276 Silicon with meter l4 JIS Intrinsic Safety Ex ia IIC T4 Certificate Description C16406 3051CD CG Australian Certifications I7 SAA Intrinsic Safety Certification No AUS Ex 1249X Ex ia IIC T4
42. dapters Adapters can be rotated to give connection centers of 2 00 51 2 126 54 or 2 25 57 3051 3031A06A B06A Coplanar Flange Mounting Configurations with Optional Bracket B4 for 2 in Pipe or Panel Mounting 2 8 72 36 x 11 2 Bolts for Panel Mounting Not Supplied 2 8 71 eg aa i 318 16 x 11 4 Bolts for Mounting to Transmitter 2 inch U Bolt for Pipe Mounting mit TR f m PIPE MOUNTING 3051 3031A04H 104A M04A L04A J04A 3 3 6 0 152 83 Dimensions are in inches millimeters 17 Rosemount 3051 Product Data Sheet 00813 0100 4001 Rev FA August 2004 Traditional Flange Mounting Configurations with Optional Brackets for 2 in Pipe or Panel Mounting Traditional Flange Panel Mounting Bracket option B2 B8 10 1 257 5 16 x s Bolts for Panel Mounting Not Supplied gt D 6 2 158 gt PANEL MOUNTING BRACKET 1 2 14 NPT Conduit Connection Two Places Other Sizes Available 0 75 20 Clearance for Cover Removal Transmitter Circuitry Terminal Connections gt 114 18 NPT on Traditional Flange for Pressure Connection Without the Use o Flange Adapters Connection Per IEC 61518 2 126 54 0 12 in Connection Centers 1 7 43 Traditional Flange 2 in Pipe Mounting Bracket option B1 B7 BA 4 4 2 106
43. ed PlantWeb Functionality Optional functionality includes eo performance diagnostics and Control POWERS Anywhere Performance diagnostics PlantWeb such as plugged impulse line detection and statistical process monitoring go beyond the transmitter to evaluate the performance of the entire measurement system Control Anywhere provides user configurable transmitter resident function blocks such as PID Math and signal characterization Q Rosemount Pressure Solutions Rosemount 3051S Series of Instrumentation Scalable pressure flow and level measurement solutions improve installation and maintenance practices Rosemount 3095MV Mass Flow Transmitter Accurately measures differential pressure static pressure and process temperature to dynamically calculate fully compensated mass flow Rosemount 305 and 306 Integral Manifolds Factory assembled calibrated and seal tested manifolds reduce on site installation costs Rosemount 1199 Diaphragm Seals Provides reliable remote measurements of process pressure and protects the transmitter from hot corrosive or viscous fluids Orifice Plate Primary Element Systems Rosemount 1495 and 1595 Orifice Plates 1496 Flange Unions and 1497 Meter Sections A comprehensive offering of orifice plates flange unions and meter sections that is easy to specify and order The 1595 Conditioning Orifice provides superior performance in tight fit applications Annubar Flowmeter Series Rosemount
44. el Span and Zero Adjustments Standard d Electronics Housing Terminal Block Cover O ring Cover lectronics Board Nameplate Sensor Module Y Housing Rotation Set Screw 180 Maximum Housing Rotation without Further Disassembly Coplanar Flange Process O Ring Drain Vent Valve Xs WO a Flange Adapters Flange Adapter O Ring Flange Alignment Screw Not Pressure Retaining 3031B08A 1 Span and Zero Adjustments are not available with fieldbus or profibus protocols Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 3051C Coplanar Flange Dimensional Drawing Differential Pressure Transmitter Shown 5 0 127 4 3 110 1 2 14 NPT Certification Conduit Connection 4 1 Two Places Other P 105 Sizes e 0 75 20 Clearance CM for Cover Removal 0 75 20 Clearance E for Cover Removal SVO ZW fj AWE Ar PEN Terminal Connections Transmitter Circuitry Nameplate 8 2 209 Drain Vent Valve Housing Rotation Set Screw Coplanar Flange Process Connection La Per IEC 61518 2 126 54 0 012 in Connection Centers 4 18 NPT on Coplanar Flange for Pressure Connection without the Use of Flange Adapters 4 6 4 163 112 14 NPT on Optional Flange A
45. epending on transmitter type and range k Contact an Emerson Process Management representative C6 CSA Explosion proof and Intrinsic Safety Approval x 3 Ke CSA and ATEX Explosion proof and Intrinsic Safety Approval combination of C6 and K8 d KB FM and CSA Explosion proof and Intrinsic Safety Approvals combination of K5 and C6 K7 SAA Flame proof and Intrinsic Safety Approvals combination of I7 N7 and E7 Kg ATEX Flame proof and Intrinsic Safety Approvals combination of 11 and E8 KD CSA FM and ATEX Explosion proof and Intrinsic Safety Approval combination of K5 C6 11 and E8 I7 SAA Intrinsic Safety Certification 3 E7 SAA Flame proof Certification j N7 SAA Type N Certification f IA ATEX Intrinsic Safety for FISCO for FOUNDATION fieldbus protocol only d Code Bolting Options CD CG CA L4 Austenitic 316 SST Bolts L5 ASTM A 193 Grade B7M Bolts e L6 Monel Bolts Code Meters Optional CD CG CA M5 LCD display for Aluminum Housing Housing Codes A B C and D only e e e M6 LCD display for SST Housing Housing Codes J K L and M only e Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 TABLE 11 3051C Differential Gage and Absolute Pressure Transmitters Not Applicable Applicable Code Other Options 03D CG CA Q4 Calibration Data Sheet Q8 Material Traceability Certification per EN 10204 3 1 B Only avail
46. er 0 8 3 2 V dc Output with Digital Signal Based on HART Protocol Output Code M only Analog Output Levels Compliant with NAMUR Recommendation NE 43 27 June 1996 Analog Output Levels Compliant with NAMUR Recommendation NE 43 Low Alarm Configuration Hydrostatic Testing Cleaning for Special Service Cleaning for 1 PPM Chlorine Fluorine 0 04 accuracy to 5 1 turndown Range 1 4 External Ground Screw Assembly 30511 G 5 F 2A 2 1 A B4 1 3051TG lower range limit varies with atmospheric pressure 2 Materials of Construction comply with recommendations per NACE MRO0175 ISO 15156 for sour oil field production environments Environmental limits apply to certain materials Consult latest standard for details Selected materials also conform to NACE MRO0103 for sour refining environments 3 Not available with low power Option Code M 4 Not available with fieldbus output code F or Profibus protocols output code W 5 Local zero and span adjustments are standard unless Option Code J1 or J3 is specified 6 NAMUR Compliant operation is pre set at the factory and cannot be changed to standard operation in the field 7 The V5 option is not needed with T1 option external ground screw assembly is included with the T1 option Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 TABLE 13 3051L Flange Mounted Liquid Level Transmitter Model Transmitter Type 3051L Flange Mounted Liquid Level Transmit
47. figuration Completed CDS 00806 0100 4001 required with order C20 0 8 3 2 V dc Output with Digital Signal Based on HART Protocol Output Code M only c44 Analog Output Levels Compliant with NAMUR Recommendation NE 43 cN Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Configuration Low P1 Hydrostatic Testing P2 Cleaning for Special Service P3 Cleaning for lt 1 PPM Chlorine Fluorine e DF 1 2 14 NPT flange adapters SST D8 Ceramic Ball Drain Vents V5 External Ground Screw Assembly Typical Model Number 3051HG 2 A 2 2 A H 2 1 A B5 1 Materials of Construction comply with recommendations per NACE MRO0175 ISO 15156 for sour oil field production environments Environmental limits apply to certain materials Consult latest standard for details Selected materials also conform to NACE MRO01003 for sour refining environments 2 Not available with low power Option Code M 3 Not available with fieldbus output code F or profibus protocols output code W 4 NAMUR Compliant operation is pre set at the factory and cannot be changed to standard operation in the field 5 The V5 option is not needed with the T1 option external ground screw assembly is included with the T1 option 35 Rosemount 3051 OPTIONS Standard Configuration Unless otherwise specified transmitter is shipped as follows ENGINEERING UNITS Differential Gage inH5O Range 0 1 2 and 3 ps
48. h Output code M only Analog Output Levels Compliant with NAMUR Recommendation NE 43 Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Configuration Low Ceramic Ball Drain Vents External Ground Screw Assembly Lower Housing Flushing Connections Ring Material Number Size 2in 3in 4in SST 1 114 x SST 2 1 4 z Hastelloy C276 1 1 4 i Hastelloy C276 2 1 4 3 A SST 1 1 2 SST 2 1 2 5 Hastelloy C276 1 1 2 i Hastelloy C276 2 1 2 x 7 Typical Model Number 1 Not available with low power Option Code M 2 Not available with fieldbus output code F or profibus protocols output code W 3 Local zero and span adjustments are standard unless Option Code J1 or J3 is specified 4 NAMUR Compliant operation is pre set at the factory and cannot be changed to standard operation in the field 5 The V5 option is not needed with the T1 option external ground screw assembly is included with the T1 option 6 Not available with Option Codes AO BO and GO Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 TABLE 14 3051H Pressure Transmitter for High Temperature Processes Not Applicable Applicable Model Transmitter Type Select One HD HG 3051HD Differential Pressure Transmitter for High Temperature Processes 3051HG Gage Pressure Transmitter for High Temperature Processes Code 3051HD 3051HG 2 250 to 250 inH20 2 5 inH5O 250 to 250
49. i Range 4 and 5 Absolute 3051T psi all ranges 4 mA 1 V dc 0 engineering units above 20 mA 5 V dc Upper range limit Output Linear Flange type Specified model code option Flange material Specified model code option O ring material Specified model code option Drain vent Specified model code option Integral meter Installed or none Alarm Upscale Software tag Blank 1 Not applicable to fieldbus Custom Configuration HART protocol only If Option Code C1 is ordered the customer may specify the following data in addition to the standard configuration parameters Output Information Transmitter Information LCD display Configuration e Hardware Selectable Information e Signal Selection Refer to the HART Protocol C1 Option Configuration Data Sheet on page 38 Tagging 3 options available e Standard SST hardware tag is wired to the transmitter Tag character height is 0 125 in 3 18 mm 56 characters maximum Tag may be permanently stamped on transmitter nameplate upon request 56 characters maximum Tag may be stored in transmitter memory 30 characters maximum Software tag is left blank unless specified Commissioning tag fieldbus only A temporary commissioning tag is attached to all transmitters The tag indicates the device ID and allows an area for writing the location Optional Rosemount 305 or 306 Integral Manifolds Factory assembled to 3051C and 3051T transmi
50. ic Safety Approval combination of C6 and K8 FM and CSA Explosion proof and Intrinsic Safety Approvals combination of K5 and C6 SAA Flame proof and Intrinsic Safety Approvals combination of I7 N7 and E7 ATEX Flame proof and Intrinsic Safety Approvals combination of 11 and E8 CSA FM and ATEX Explosion proof and Intrinsic Safety Approval combination of K5 C6 11 and E8 SAA Intrinsic Safety Certification JIS Flame proof Certification SAA Flame proof Certification SAA Type N Certification ATEX Intrinsic Safety and Dust Certification ATEX Type N and Dust Certification ATEX Flame proof and Dust Certification NSF drinking water approval ATEX Intrinsic Safety for FISCO for FOUNDATION fieldbus protocol only Other Options Q4 Q8 Q16 QP QS J145 J346 M5 M6 T1 c14 c20 CA 4 6 CN P1 P2 P3 P8 V5 Typical Model Number Calibration Data Sheet Material Traceability Certification per EN 10204 3 1 B NOTE This option applies to the process connection only Surface finish certification for sanitary remote seals Calibration certification and tamper evident seal Quality certification for safety Local Zero Adjustment Only No Local Zero or Span Adjustment LCD display for Aluminum Housing Housing Codes A B C and D only LCD display for SST Housing Housing Codes J K L and M only Transient Protection Terminal Block Custom Software Configuration Completed CDS 00806 0100 4001 required with ord
51. inH5O 2 5 inH O 0 62 to 0 62 bar 6 2 mbar 0 62 to 0 62 bar 6 2 mbar 3 1000 to 1000 inH2O 10 inH5O 407 to 1000 inH5O 10in H20 2 5 to 2 5 bar 25 mbar 1 01 to 2 5 bar 25 mbar 4 9300 to 300 inH2O 3 psi 14 7 to 300 psi 3 psi 747 to 747 mbar 0 2 bar 1 01 to 20 7 bar 0 2 bar 5 2000 to 2000 psi 20 psi 14 7 to 2000 psig 20 psi 138 to 138 bar 1 4 bar 1 01 to 138 bar 1 4 bar NOTE 3051HG lower range limit varies with atmospheric pressure Code Output HD HG A 4 20 mA with Digital Signal Based on HART Protocol M Low Power 1 5 V dc with Digital Signal Based on HART Protocol See Option Code C2 for 0 8 3 2 V dc Output e e Not available with hazardous certification Option Codes 11 N1 E4 K6 and K8 F FOUNDATION fieldbus i 1 W Profibus PA Code Process Connection HD HG Process Flange Material Drain Vent 2 SST SST e e 70 SST Hastelloy C276 2 316L SST 7 30 Hastelloy C276 5 Tantalum e Code O ring Material B HG A Glass Filled PTFE e e D D C 200 Silicone z H Inert e e N Neobee M 20 2 SST e e 1 Silicone e 2 Inert Halocarbon e e Code Housing Material Conduit Entry Size A Polyurethane covered Aluminum 72 14 NPT e e B Polyurethane covered Aluminum M20 x 1 5 CM20 C Polyurethane covered Aluminum PG 13 5 e e D Polyurethane covered Aluminum GY J SST Y 2 14 NPT e e K SST M20 x 1 5 CM20 e e L SST PG 13 5 e e M SST G
52. ing 112 14 NPT Conduit LOWER HOUSING Connections optional Transmitter Circuitry 0 75 19 Clearance for Cover Removal Terminal Connections S 0 75 19 Clearance for Cover Removal AE Flushing Connection Nameplate Diaphragm Assembly and Mounting Flange 114 18 NPT on Flange for Pressure Drain Vent Connection without the Use of Valve Mounting Adapters 3051 3031B27A 27B 27C 3031B27D C27E Dimensions are in inches millimeters 22 Product Data Sheet 00813 0100 4001 Rev FA August 2004 TABLE 10 3051L Dimensional Specifications Except where indicated dimensions are in inches millimeters ASME B 16 5 ANSI 150 ASME B 16 5 ANSI 300 ASME B 16 5 ANSI 600 DIN PN 10 40 DIN PN 25 40 DIN PN 10 16 Pipe Size 2 51 3 76 4 102 2 51 3 76 4 102 2 51 3 76 DN 50 DN 80 DN 100 DN 100 Flange Thickness 1 12 28 1 31 33 1 31 33 32 1 50 38 1 62 41 1 12 28 1 37 35 26 mm 30 mm 30 mm 26 mm 1 Tolerances are 0 040 1 02 0 020 0 51 Bolt Circle Diameter 4 75 121 6 0 152 7 5 191 5 0 127 6 62 168 7 88 200 5 0 127 6 62 168 125 mm 160 mm 190 mm 180 mm Outside Diameter 6 0 152 5 191 0 229 5 165 8 25 210 10 0 254 6 5 165 6 62 168 165 mm 200 mm 235 mm 220 mm No of Bolt Hole Diameter 0 75 19 0 75 19 0 75 19 0 75 19
53. ing Position Effects Rosemount 3051C Zero shifts up to 1 25 inH5O 3 11 mbar which can be calibrated out No span effect Rosemount 3051H Zero shifts up to 5 inH5O 127 mmH5O which can be calibrated out No span effect Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051L With liquid level diaphragm in vertical plane zero shift of up to 1 inH5O 25 4 mmH5O With diaphragm in horizontal plane zero shift of up to 5 inH2O 127 mmH50O plus extension length on extended units All zero shifts can be calibrated out No span effect Rosemount 3051T CA Zero shifts up to 2 5 inH5O 63 5 mmH50O which can be calibrated out No span effect Vibration Effect All Models Measurement effect due to vibrations is negligible except at resonance frequencies When at resonance frequencies vibration effect is less than 0 1 of URL per g when tested between 15 and 2000 Hz in any axis relative to pipe mounted process conditions Power Supply Effect All Models Less than 0 005 of calibrated span per volt RFI Effects All Models 0 1 of span from 20 to 1000 MHz and for field strength up to 30 V m Transient Protection Option Code T1 All Models Meets IEEE C62 41 Category B 6 kV crest 0 5 us 100 kHz 3 kV crest 8 x 20 microseconds 6 kV crest 1 2 x 50 microseconds Meets IEEE C37 90 1 Surge Withstand Capability SWC 2 5 kV crest 1 25 MHz wave form General Specifications Response
54. is a registered trademark of one of the Emerson Process Management group of companies Complete Point Solutions Coplanar and Multivariable are trademarks of Rosemount Inc HART is a registered trademark of the HART Communications Foundation Hastelloy is a registered trademarks of Haynes international Inc Monel is a registered trademark of the Special Metals Corporation group of Companies Syltherm 800 Dow Corning and D C are registered trademarks of Dow Corning Co Teflon is a registered trademark of E I du Pont de Nemours amp Co Neobee M 20 is a registered trademark of Stephan Chemical Co The 3 A symbol is a registered trademark of the 3 A Sanitary Standards Symbol Council FOUNDATION fieldbus is a registered trademark of the Fieldbus Foundation Fluorinert is a registered trademark of 3M Company All other marks are the property of their respective owners Rosemount Model 3051 Smart Pressure Transmitters may be protected by one or more of the following U S Patent Nos 4 370 890 4 466 290 4 612 812 4 791 352 4 798 089 4 818 994 4 833 922 4 866 435 4 926 340 4 988 990 and 5 028 746 Mexico Patentado No 154 961 May depend on model Other foreign patents issued and pending Emerson Process Management Rosemount Inc Emerson Process Management Emerson Process Management Asia Beijing Rosemount Far East 8200 Market Boulevard GmbH amp Co Pacific Private Limited Instrument Co Limited Chanhassen MN 55317 USA Argel
55. less steel with Series 300 stainless steel bolts 37 Product Data Sheet 00813 0100 4001 Rev FA Rosemount 3051 August 2004 HART Protocol C1 Option Configuration Data Sheet Default Value CONFIGURATION DATA SHEET Customer P O No Model No Line Item SST Tag No Software Tag I L L OUTPUT INFORMATION Software Selectable 4 mA 1 0 8 Volts O 20 mA 5 3 2 Volts Upper Range Limit x Pressure Units inH 02 x psi x Pa ftH 0 inHg bar kPa g cm mbar Torr mmH o inH O at 4 c L Atm L kg cm L mmHg L mmH 0 at 4 C 9 Output Linear m Square Root For DP transmitters only Damping 0 00 sec 0 05 sec 0 10 sec 0 20 sec 0 40 sec 0 80 sec 1 60 sec 3 20 sec 12 8 sec L 25 6 sec TRANSMITTER INFORMATION Software Selectable Descriptor I I L L L L LL LL I 16 characters Message pese Te esee eso sedes p prs e pep sepe ed roce sees pes 32 characters pae JT VETLIL VETE Day Month Year Local Span and Zero Enabiea Disabled 1 Default values may be different outside the U S A Consult an Emerson Process Management Representative for details 2 inH20 for CD CG ranges 1 3 3 psi for CD CG range 4 and 5 all CA ranges 4 C1 option required for configuration of this parameter 5 Not available with low power output 38 Product Data Sheet 00813
56. measure of real world transmitter performance Using superior sensor technology and engineered for optimal performance the 3051 delivers unprecedented 0 04 reference accuracy resulting in total operating performance of 0 15 Superior total performance equates to reduced variability and improved plant safety Five year installed stability of 0 125 Transmitter stability is a critical measure of transmitter performance over time Through aggressive simulation testing beyond standard IEC 770 testing the 3051 has proven its ability to maintain performance over a five year period under the most demanding process conditions Superior transmitter stability reduces calibration frequency to save operation and maintenance costs Unmatched dynamic performance In dynamic applications speed of measurement is as important as repeatability The 3051 responds up to eight times faster than the typical pressure transmitter to detect and control variations quickly and efficiently Superior dynamic response yields more accurate measurements to reduce variability and increase profitability Coplanar platform enables complete point solutions The versatile Coplanar platform design enables the best process connection for pressure flow and level applications Right out of the box the solution arrives factory calibrated pressure tested and ready to install Only the 3051 has a flexible design to reduce engineering and inventory costs Advanc
57. ns for Safe Use X Where the equipment is installed such that there is an unused conduit entry it must be sealed with a suitable blanking plug to maintain the IP40 degree of protection Any blanking plug used with the equipment shall be of a type which requires the use of a tool to effect its removal Voltage source shall not exceed 60V ac or 75V dc Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified Once a device labeled with multiple approval types is installed it should not be reinstalled using any other approval types Permanently mark the approval label to distinguish it from unused approval types K5 KB KD K6 K8 K7 E5 and I5 combination K5 and C6 combination K5 C6 I1 and E8 combination C6 11 and E8 combination E8 and 11 combination E7 I7 and N7 combination Rosemount 3051 13 Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications IA FM Approvals E5 Explosion Proof for Class l Division 1 Groups B C and D Dust Ignition Proof for Class II Division 1 Groups E F and G Dust Ignition Proof for Class lll Division 1 T5 Ta 85 C Factory Sealed Enclosure Type 4X Intrinsically Safe for use in Class l Division 1 Groups A B C and D Class ll Division 1 Groups E F and G Class Ill Division 1 when connected per Rosemount drawing 03031 1019 Non incendive for Class l Division
58. ount FD Level Flange SST 3 in ANSI Class 300 Vertical Mount PIP DIN Level Flange SST DN 50 PN 40 Vertical Mount FQ DIN Level Flange SST DN 80 PN 40 Vertical Mount e e e Code Integral Mount Manifold Options Requires Materials of Construction Code 0 S5 Assemble to Rosemount 305 Integral Manifold specified separately see the Rosemount 305 and 306 e e e Integral Manifolds PDS document number 00813 0100 4733 Code Integral Mount Primary Elements Optional CD CG CA S4 Factory Assembly to Rosemount Primary Element Annubar or Rosemount 1195 Integral Orifice f ES E With the primary element installed the maximum operating pressure will equal the lesser of either the transmitter or the primary element Option is available for factory assembly to range 1 4 transmitters only S3 Factory Assembly to Rosemount 405 Primary Element Diaphragm Seal Assemblies Optional Code NOTE Standard flange and adapter bolts are austenitic 316 SST S1 One Diaphragm Seal Direct Mount or Capillary Connection Type S2 Two Diaphragm Seals Direct Mount or Capillary Connection Type Optional All Welded Diaphragm Seal Systems for high vacuum applications Code NOTE Standard flange and adapter bolts are austenitic 316 SST S7 One Diaphragm Seal All Welded System Capillary Connection Type e S8 Two Diaphragm Seals All Welded System Capillary Connection Type e S0 One Diaphragm
59. r Neobee M 20 or propylene glycol and water 3051H inert Neobee M 20 or D C Silicone 200 Paint Polyurethane Cover O rings Buna N Shipping Weights Refer to Shipping Weights on page 37 Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051 Product Certifications Approved Manufacturing Locations Rosemount Inc Chanhassen Minnesota USA Emerson Process Management GmbH amp Co Wessling Germany Emerson Process Management Asia Pacific Private Limited Singapore Beijing Rosemount Far East Instrument Co LTD Beijing China European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at www rosemount com A hard copy may be obtained by contacting an Emerson Process Management representative ATEX Directive 94 9 EC All 3051 transmitters comply with the ATEX Directive European Pressure Equipment Directive PED 97 23 EC 3051CA4 3051CG2 3 4 5 3051CD2 3 4 5 also with P9 option 3051HD2 3 4 5 3051HG2 3 4 5 3051PD2 3 and 3051PG2 3 4 5 Pressure Transmitters QS Certificate of Assessment EC No PED H 20 Module H Conformity Assessment All other 3051 3001 Pressure Transmitters Sound Engineering Practice Transmitter Attachments Diaphragm Seal Process Flange Manifold Sound Engineering Practice Electro Magnetic Compatibility EMC 89 336 EEC All
60. srieder Feld 3 1 Pandan Crescent No 6 North Street T U S 1 800 999 9307 82234 Wessling Singapore 128461 Hepingli Dong Cheng District T International 952 906 8888 Germany T 65 6777 8211 Beijing 100013 China F 952 949 7001 T 49 8153 9390 F 65 6777 0947 T 86 10 6428 2233 F 49 8153 939172 AP RMT Specialistoemersonprocess com F 86 10 6422 8586 www rosemount com vA EMERSON 2004 Rosemount Inc All rights reserved Process Management
61. te filled PTFE Process Isolating Diaphragms o o m 2 Isolating Diaphragm Material 2 316L SST e e e e Hastelloy C276 3 Monel Tantalum z Gold plated Monel Gold plated SST 10 Product Data Sheet 00813 0100 4001 Rev FA August 2004 Rosemount 3051L Process Wetted Parts Flanged Process Connection Transmitter High Side Process Diaphragms Including Process Gasket Surface e 316L SST Hastelloy C276 or Tantalum Extension CF 3M Cast version of 316L SST material per ASTM A743 or Hastelloy C276 Fits schedule 40 and 80 pipe Mounting Flange e Zinc cobalt plated CS or SST Reference Process Connection Transmitter Low Side Isolating Diaphragms e 316L SST or Hastelloy C276 Reference Flange and Adapter CF 8M Cast version of 316 SST material per ASTM A743 Non Wetted Parts Electronics Housing Low copper aluminum or CF 3M Cast version of 316L SST material per ASTM A743 NEMA 4X IP 65 IP 66 Coplanar Sensor Module Housing CF 3M Cast version of 316L SST material per ASTM A743 Bolts ASTM A449 Type 1 zinc cobalt plated carbon steel ASTM F593G Condition CW1 Austenitic 316 SST ASTM A193 Grade B7M zinc plated alloy steel Monel K 500 Sensor Module Fill Fluid Silicone oil D C 200 or Fluorocarbon oil Halocarbon or Fluorinert FC 43 for 3051T Process Fill Fluid 3051L and 3051H only 3051L Syltherm XLT D C Silicone 704 D C Silicone 200 inert glycerin and wate
62. tegral Manifold 40 to 300 F 40 to 149 C 0 to 185 F 18 to 85 C Inert Fill Sensor 3051H Process Fill Fluid D C Silicone 200 40 to 375 F 40 to 191 C Inert 50 to 350 F 45 to 177 C 0 to 375 F 18 to 191 C 3051T Process Fill Fluid Neobee M 209 0 Silicone Fill Sensor Inert Fill Sensor 40 to 250 F 40 to 121 C 22 to 250 F 30 to 121 C 3051L Low Side Temperature Limits 40 to 250 F 40 to 121 C 0 to 185 F 18 to 85 C Silicone Fill Sensor Inert Fill Sensor 3051L High Side Temperature Limits Process Fill Fluid Syltherm XLT 100 to 300 F 73 to 149 C D C Silicone 704 60 to 400 F 15 to 205 C D C Silicone 200 40 to 400 F 40 to 205 C Inert 50 to 350 F 45 to 177 C Glycerin and Water 0 to 200 F 18 to 93 C Neobee M 20 0 to 400 F 18 to 205 C Propylene Glycol and Water 0 to 200 F 18 to 93 C 1 Process temperatures above 185 F 85 C require derating the ambient limits by a 1 5 1 ratio 0 6 1 ratio for the 3051H 2 220 F 104 C limit in vacuum service 130 F 54 C for pressures below 0 5 psia 3 3051CD0 process temperature limits are 40 to 212 F 45 to 100 C 4 160 F 71 C limit in vacuum service 5 Not available for 3051CA Humidity Limits 0 100 relative humidity Turn On Time Performance within specifications
63. ter Code Pressure Ranges Range Min Span 2 250 to 250 inH2O 2 5 inH5O 0 6 to 0 6 bar 6 2 mbar 3 1000 to 1000 inH5O 10 inH5O 2 5 to 2 5 bar 25 mbar 4 300 to 300 psi 3 psi 20 7 to 20 7 bar 0 2 bar Code Output A 4 20 mA with Digital Signal Based on HART Protocol M Low Power 1 5 V dc with Digital Signal Based on HART Protocol See Option Code C2 for 0 8 3 2 V dc Output Not available with hazardous certification Option Codes 11 N1 E4 K6 and K8 F FOUNDATION fieldbus W Profibus PA High Pressure Side ler Diaphragm Size Material Extension Length GO 2 in DN 50 316L SST Flush Mount Only HO 2 in DN 50 Hastelloy C276 Flush Mount Only JO 2 in DN 50 Tantalum Flush Mount Only AO 3 in DN 80 316L SST Flush Mount A2 3 in DN 80 316L SST 2 in 50 mm A4 3 in DN 80 316L SST 4 in 100 mm A6 3 in DN 80 316L SST 6 in 150 mm BO 4 in DN 100 316L SST Flush Mount B2 4 in DN 100 316L SST 2 in 50 mm B4 4 in DN 100 316L SST 4 in 100 mm B6 4 in DN 100 316L SST 6 in 150 mm CO 3 in DN 80 Hastelloy C276 Flush Mount C2 3 in DN 80 Hastelloy C276 2 in 50 mm C4 3 in DN 80 Hastelloy C276 4 in 100 mm C6 3 in DN 80 Hastelloy C276 6 in 150 mm DO 4 in DN 100 Hastelloy C276 Flush Mount D2 4 in DN 100 Hastelloy C276 2 in 50 mm D4 4 in DN 100 Hastelloy C276 4 in 100 mm D6 4 in DN 100 Hastelloy C276 6 in 150 mm EO 3 in DN 80 Tantalum Flush Mount Only FO 4 in DN 100 Tantalum Flush Mount Only 30 Product Data Sheet
64. tters Refer to the following Product Data Sheet document number 00813 0100 4733 for additional information Optional Three Valve Manifolds Packaged Separately e Part No 1151 0150 0001 3 Valve Manifold Carbon Steel e Part No 1151 0150 0002 3 Valve Manifold 316 SST 1 Not applicable to fieldbus 36 Product Data Sheet 00813 0100 4001 Rev FA August 2004 Optional Diaphragm and Sanitary Seals Refer to Product Data Sheet 00813 0100 4016 or 00813 0201 4016 for additional information Output Information Output range points must be the same unit of measure Available units of measure include inH2O inH20 4 c psi Pa inHg ftH20 bar kPa mmH20 mmH20 4 e mbar torr mmHg g cm2 kg cm2 atm 1 Not available on low power or previous versions LCD display M5 Digital Meter 5 Digit 2 Line LCD Direct reading of digital data for higher accuracy Displays user defined flow level volume or pressure units Displays diagnostic messages for local troubleshooting 90 degree rotation capability for easy viewing M6 Digital Meter with 316 Stainless Steel Cover e For use with stainless steel housing option housing codes J K and L Local Span and Zero Adjustment Transmitters ship with local span and zero adjustments standard unless otherwise specified Non interactive external zero and span adjustments ease calibration Magnetic switches replace standard potentiometer adjustments to optimize performance
65. uring its expected lifetime Product Data Sheet 00813 0100 4001 Rev FA August 2004 Japanese Certifications E4 JIS Flame Proof Ex d IIC T6 Certificate Description C15852 3051C D 1 FOUNDATION Fieldbus no meter C15853 3051C D 1 FOUNDATION Fieldbus with meter C15858 3051T G 1 FOUNDATION Fieldbus SST Silicon no meter C15859 3051T G 1 FOUNDATION Fieldbus Hastelloy C276 Silicon no meter C15860 3051T G 1 FOUNDATION Fieldbus SST Silicon with meter C15861 3051T G 1 FOUNDATION Fieldbus Hastelloy C276 Silicon with meter Australian Certifications I7 SAA Intrinsic Safety Certification No AUS Ex 1249X Ex ia IIC T4 Tamp 60 C IP66 When connected per Rosemount drawing 03031 1026 TABLE 9 Input Parameters U 2 30 V 300 mA P 21 3W Cj 2 0 uF L 0 uH Special Conditions for Safe Use X The apparatus may only be used with a passive current limited power source Intrinsic Safety application The power source must be such that Po x Uo lo 4 Modules using transient protection in the terminal assembly T1 transient protection models the apparatus enclosure is to be electrically bonded to the protective earth The conductor used for the connection shall be equivalent to a copper conductor of 4 mm2 minimum cross sectional area E7 N7 Rosemount 3051 SAA Explosion Proof Flame Proof Certification No AUS Ex 1347X Ex d IIC T6 Tag 40 C Ex d IIC T
66. xplosion Proof and intrinsically safe approval Intrinsically safe for Class I Division 1 Groups A B C and D when connected in accordance with Rosemount drawings 03031 1024 Temperature Code T3C Explosion Proof for Class Division 1 Groups B C and D Dust Ignition Proof for Class Il and Class III Division 1 Groups E F and G Suitable for Class I Division 2 Groups A B C and D hazardous locations Enclosure type 4X factory sealed For input parameters see control drawing 03031 1024 11 Rosemount 3051 European Certifications I1 N1 E8 12 ATEX Intrinsic Safety and Dust Certification No BAS 97ATEX1089X 9 Il 1 GD EEx ia IIC T5 60 x T4 lt 40 C EEx ia IIC T4 60 x T4 lt 70 C Dust Rating T80 C 20 x T4 lt 40 C IP66 ce 1180 TABLE 5 Input Parameters U 30V l 200 mA P 0 9W C 0 012 uF Special Conditions for Safe Use X When the optional transient protection terminal block is installed the apparatus is not capable of withstanding the 500V insulation test required by Clause 6 4 12 of EN50020 1994 This must be taken into account when installing the apparatus ATEX Type n and Dust Certification No BAS OOATEX3105X II 3 GD EEx nL IIC T5 40 lt T4 lt 70 C U 55 Vdc max Dust rating T80 C 20 lt T4 lt 40 C IP66 CE Special Conditions for Safe Use X When the optional transient protection terminal block is installed the appar