1. 4 5 Continuity check e Press FUNC Key and select the function at n mode e Connect the test clip to the resistance If continity exists i e resistance less than 30 Q built in buzzer will sound 5 AUTO POWER OFF APO e To extend the battery life Auto Power Off function is provided If no key operations of range changing happen about 10 minutes the meter will be turned off automatically e When APO happens the state of the meter is saved 6 MAINTENANCE 6 1 General Maintenance Periodically wipe the case with a damp cloth mild detergent Do not use abrasives or solvents 6 2 Battery replacement A Before replacing the battery disconnect test leads from any circuit under test turn the meter off and remove test Leeds from the input terminals Use the following procedure When the battery voltage drop below proper operation range the symbol will appear on the LCD display and the battery need to be replaced e Press the battery cover and towards arrowhead direction to open the battery cover e Replace the battery with two new 1 5 V batteries AG 13 e Replace the battery cover PEUGUl WWW AXIOMET EU
2. A xX C i Hii MET AUTO SCAN Pen R C D Meter for SMD AX 507B USER S MANUAL nN lt CS Ww XM ET 1 GENERAL INSTRUCTIONS This auto scan pen R C D meter fir SMD could fast precise measure small chip components To get the best service from this meter please read this user s manual carefully and observe the detailed safety precautions strictly 1 1 Precautions safety measures e When using this meter the user must observe all normal safety rules concerning 1 1 1 During use e Use the meter before must warm up 30 seconds e If the meter is used near noise generating equipment be aware that display may become unstable or indicate large errors e Do not use the meter if it looks damaged e Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired e Do not operate the meter around explosive gas vapor or dust e To avoid damages to the instrument do not exceed the maximum limits of the input values e Caution Avoid working with voltages above 50VDC or 36VAC rms Such voltages pose a shock hazard and damage the meter e When using this meter keep your fingers away from the metal of the meter e Before changing functions disconnect the test clip from the circuit under test e Replace the battery when the symbol appears With a low battery the meter might produce false display 1 1 2 Symbols Symbols used in this manual and on thr meter A Caut
3. ion refer to the instruction manual Incorrect use may result in damage to the device or its components C Conforms to IEC1010 1 1 3 Instructions e Before operating the meter always disconnect from all sources of electric current and make sure you are not charged with static electricity which may destroy internal components e Any adjustment maintenance ot repair work carried out on the meter while it is live should be carried out only by appropriately qualified personnel after having taken into account the instructions in this present manual e If any faults or abnormalities are observed take the instrument out of service and ensure that it can not be used until it has been checked out e If the meter is not going to be used for a long time take out the battery and do not store the meter in high temperature or high humidity environment e Never use the meter unless the back cover and battery cover are in place and fastened fully PEUGUl WWW AXIOMET EU 2 DESCRIPTION 2 1 Instrument Familiarization Cathode Anode RANGE key FUNC KEY LCD DISPLAY Battery cover DuhKRWN 2 2 LCD Display y 4b pe ABBR 2 3 FUNC Key Function key Press this key longer than 1 second the meter will turn on and enter auto scan mode Press this key less than 1 second could select the target measurement function Press the key longer than 2 seconds the meter will enter sleep mode 2 4 RANGE key Change
4. its at 18 C to 28 64 F to 82 F with relative humidity to 80 A 3 2 1 Resistance Caution when working with voltages above 50 V DC or 36V AC rms Range Resolution Accuracy 3000 6000 0 10 1 2 of rdg 2 digits 3kQ 6kQ 10 30kQ 60kQ 100 300kQ 600kQ 1000 3MQ 6MQ 1kO 30MQ 60MQ 10kO 2 0 of rdg 5 digits EUG WWW AXIOMET EU 3 2 2 Capacitance Range Resolution Accuracy 3nF 6nF 1pF 5 0 of rdg 5 digits 30nF 60nF 10pF 3 0 of rdg 3 digits 300nF 600nF 100pF 3uF 6uF 1nF 30uF 60uF 10nF 5 0 of rdg 3 digits 300uF 600uF 100nF 3mF 6mF 1uF 30mF 60mF 10uF unspecified Keep two pins of the capacitance in short before maeasuring 3 2 3 Diode Test Range Desription Test Condition gt Display read approx Forward Forward DC Current approx voltage of diode 1mA Reversed DC Voltage 2V approx 2 8V 3 2 4 Continuity check The buzzer generates 2 KHZ beep whenever the reading is less than 30 Q 4 OPERATING INSTRUCTION 4 1 Auto scan measurement mode e Pressing this key longer than 1 second the metter will turn on and enter auto mode now you can measurement ohm diode capatitance continuity check Note e The range when auto scan mod Ohm 300 0 Q 3 000M 0 600 0 Q 6 000M Q Cap 3nF 300uF 6nF 600uF EUG WWW AXIOMET EU 4 2 Resistance measurement A To avoid elecrical Shock
5. or damages to the meter under test disconnect circuit power and discharge all high voltage capacitors before measuring resistance e Press FUNC Key and select the function at AS inode e Connect the test clip to the object being measured and the measured value will show on the display Note e When this mode the RANGE key is available e When the input is not connected i e at open circuit the figure OL will be displayed for the overrange condition 4 3 Capacitance measurement A To avoid electrical Srock or damages to the meter dunder test disconnect circuit Power and discharge all high voltage capacitors before measuring capacitance Keep two pins of the capacitance in short before measuring e Press FUNC Key and select the function at 4 F mode e Connect the test clip to the capacitor being measured and read the displayed value Note e When this mode the RANGE key is available e Discharge the capacitor before measuring 4 4 Diode measurement A To avoid elecrical Srock or damages to the meter dunder test disconnect circuit Power and discharge all high voltage capacitors before testing diodes e Press FUNC Key and select the function at 3 mode e Connect the pin to the anode the pin to the cathode of the diode under testing e The meter will show the approx forward voitage of the diode If the lead connection is reversed only figure OL displayed EUG WWW AXIOMET EU
6. s range When automatic mode pressing this key less than 1 second the meter will enter manual mode When manual mode pressing this key longer than 1 second the meter will enter automatic mode While in manual mode pressing thi key less then 1 second to changes the full scale range PEUGUl WWW AXIOMET EU 2 5 Terminals e Terminal receiving the anode e Terminal receiving the cathode Only for measuring the diode and the polar capacitance 3 TECHNICAL SPECIFICATIONS 3 1 General specifications e Environment conditions Pollution degree 2 Altitiude lt 2000m Operating temperature 0 40 C lt 80 C or gt 28 C Storage temperature 10 60 C lt 70 RH battery removed e Temperature Coefficient 0 1x specified accuracy VC lt 18 C or gt 28 C e MAX Voltage between terminals and earth ground 50V DC or 36V AC rms e Sample Rate 3 times sec for digital data e Display 2 2 3 digits LCD display with max reading 2999 5 5 6 digits LCD display with max reading 5999 e Over Range indication LCD will display OL e Low battery indication The E is displayed when the battery is under the proper operation range e Auto power off If there key been operated for 10 minutes the meter will auto power off to save battery energy e Power source 3 0 V battery e Dimension 181 L x35 W x20 H mm e Weight 65g Approx battery included 3 2 Measurement specifications e Accuracy of Reading number of dig