1. L 302 06 12 Thinking ahead Focused on life MORITA TwinPower Turbine Maintenance Guide D Disinfection 1 P l r Aa MANUAL Lubrication Cleaning Chuck Lubrication 3 Seconds of Spray AUTOMATED Lubrication Cleaning Chuck Lubrication 5 Seconds Beep Sounds Turbines may fail quickly if maintenance is not performed consistently or correctly Handpiece Lubrication Perform these maintenance fLubrina 3 Seconds of Spray procedures after treatment Handpiece RER gt Lubrication and before autoclaving aec toria Wipe Off Excess Lubricant Minimum of 15 Seconds of Operation Wipe Off Excess Lubricant G Sterilization 1 Cleaning e Remove bur from handpiece e Remove cutting debris blood and other contaminants with a soft brush and running water Do not fail to wash off all chemical electrolytic and other active liquids Only 2 Disinfection e Use gauze or a soft brush with disinfecting alcohol on the entire handpiece LJ e Handpieces with the following mark may be cleaned and disinfected with a thermal washer and disinfector To use a thermal washer and disinfector do not fail to follow the instructions and conditions that come with the handpiece 3 Lubrication a Manual Lubricate with AR Spray Cleaning e Lubricate the chuck and the handpiece with AR Spray for 3 seconds each La e Operate the handpiece for a minimum of 15 seconds to remove excess lubric
2. ant 1 e Wipe excess lubricant off the surface of the handpiece A AN Use the proper nozzle for type of handpiece joint Chuck Spray Nozzle Handpiece Connection Do not press down on the push cap of the handpiece during operation b Automated Lubrina with AR Spray e Perform chuck lubrication using Lubrina s built in Chuck Nozzle Line up the front end of the head with the nozzle guide and set the chuck in place Lift the handpiece up slightly to begin cleaning and lubricating for about 5 seconds beep sounds e Attach handpiece to its coupling with the chuck facing back Select Station 1 4 Wipe excess lubricant off the surface of the handpiece A Refer to the user s manual on how to operate Lubrina 4 Sterilization e Place the handpiece in a sterilization pouch and autoclave at 135 C 275 F for a minimum 135 C of 5 minutes of sterilization time Ta A Autoclave and drying temperatures must not exceed 135 C 275 F 5 Storage Remove the handpiece from autoclave unit and store carefully NOJS e Wear surgical gloves to perform maintenance e Use AR Spray only e See user s manuals for details www morita com usa 1 888 JMORITA 566 7482

Download Pdf Manuals

image

Related Search

Related Contents

Elke Loeffler_Defining Quality_FRENCH version  Fender SR-6520PD DJ Equipment User Manual  Sony DPP-SV88 Photo Printer User Manual  Forum Phone 315 Mode d`emploi  

Copyright © All rights reserved.
Failed to retrieve file