1. 2 Dk Pug ende yn rmn anl uer Gch eda IET nae ul L Harige Hec mit Prin red Pinal pri Bahri be lants EasyBuilder 500 User s Manual Key in the key words you are looking for or directly choose the index from the list 2 About Easy Builder Select About EasyBuilder The pop up message box appears as follows About EasyBuilder 500 from Weintek Labs Inc E y FasyBuilder Version 2 7 0 Ww Copyright c 2005 Wreintek Labs Inc All rights reserved The EasyBuilder version and copy right are illustrated in the message box 3 6 On line Simulation EB500 supports on line simulation The result of simulation ran on PC only with PLC is the same as that with both HMI and PLC Two methods to execute on line simulation Through Simulator from EasyManager and the other is Simulator under EB500 standard toolbar The simulator directly retrieve the data from the PLC to simulate MT500 operation By using on line simulator when testing it s save time caused for the repeated download Before simulation make sure the right connections between MT500 and the PLC and set the COM port and all parameters in the Easy Manager 1 Simulator from EasyManager Open EasyManager set the all parameters and click Online Simulator the following dialog popup es Ftemplate5z p eab File name Files of type Easyiiew Object File ecb C Open as read only Select the project and the cl
2. Step down This Attribute becomes active automatically when the window is active The Value is decremented at regular intervals as specified by the Break time until the Low limit is reached Then the Value is reset to the High limit High j x Limit Set at window Set value data is written to the designated word automatically when the maximized window containing it is maximized Set at window Set value data 1s written to the designated word automatically when the minimized window containing it 1s minimized Set at backlight off Set value data is written to the designated word automatically when the hanna backlight is turned off Note T the periodic action Vz the data in the register K the increasing decreasing parameter 6 5 Toggle Switch The toggle switch is a combination of Bit Lamp and Set Bit It represents the ON OFF status of a PLC bit address and defines a touch area when activated it can put the corresponding location address as ON or OFF Procedure to place a Toggle Switch 1 Click Toggle Switch icon 2 Fill in General Tab Description A reference name that you assign to the Toggle Switch not displayed Create Toggle Switch Object General Shape Label Description Read address es Device type LB v Device address 0 write address NE Device type LE wv Device address 0 Attribute Switch style ON Mamentar Read address Bit that c
3. Device type v Device address 10 No of words E Write address Device type LW Device address E BIN V No of words 1 Create Event Display Object General Event Display Dipbyhe d J Chmrehi U Text space Acknowledge style Doubleclick Color Acknowledge I 7 Return to nore select box Format r sequence nn Event tigger time Acknowledge time Eeturn to normal time Extended time formati WHM Short time fornat H M Event trigger date MT Extended date formati Y ML Event display object transfers one shape at bottom in order to strengthen the result of showing 5 Add a switch state that Set Bit object switch controls LB10 6 Add a text object show the content in order to raise the temperature 7 Adding one Set word object it is set up as follows Create Set Word Object General Shape Label Write address Device type Device address BIN Ww Aux Attribute bewei i dS Upperlini Window 10 1s shown by the following picture finally Raise the sura temperature T 8 Creat window is 20 the following picture shows there are a text object and one
4. fl57hfADDD system Popup Windew l 1562647350000 Popup Windewf r350000 Popup Window 1350000 MT500 adopts static resource allocation among them each basic Popup Windaw 4 fyras nad l l l l Popup Window45 07350000 window occupies 400kb each pop up window occupies 350kb each Popup Window E m Fast Window nya fast window occupies 100kb each common window Common Wiadew 77630000 occupies30kb window 0 occupies 320kb So how many components every window can be put at most should regard resource taken up in Wo eae 0 1 second window as the accurate one in order to exceed Message Queue Timer taking one second as unit can t exceed 500 at most taking 0 1 Object Queued1 f i Object Queue seconds as unit can t exceed 100 PLC Block Queue ana PLC Block Queue Message Quene is the running condition of commands in the system Sequence 2 is prior to sequence 1 EasyBuilder 500 User s Manual 4 Data Monitor Select Data Monitor can monitor the situation of the data hata Mordkor U TAO cur do nn or nor an on o6 60 G0 60 06 OO Oc UU QU OC UU E UC UU CU nn on 0n na oa nn on on OO o6 0 00 0 00 00 00 QU QU X UU QU OO CO QU iu ur F a a i m T i j As the graph above Pause 1s stop All Objects is in order to monitor the operation of all and can show the information of these objects to choose any kind or several kinds of object in Monitor Object count is information ID WI OI w
5. General Indicator Security E ditor Hardware AUR Task button Attribute Position Background color Test Alarm bar Pixels per scroll Scroll speed Ho of windows Password Startup window no Back light saver Cursor color Buzzer Enable Common window Popup window Attribute Extra no of event HTC source Internal ATC Print time tag Extended time format D H M Print date tag Extended date farmat v MJD Print Mo eror detection Message board window Mo 0 10771333 jo The larger the value of Pxels per scroll or Scroll peed are the faster the display scrolls Procedure to add Alarm Bar 1 Click the Alarm Bar Tool 2 Fill in General Tab Items Create Alarm Bar Object General Attribute Description A reference name that you assign to the Alarm Bar not displayed Display line Specifies the height of the window in lines at one message per line All messages are displayed as size 16 or 24 font Two lines are required for size 24 font Char length Specifies the width of the window in 16 point characters Namely if set as 20 it 1s the English letter of 16 to then show 20 pieces of script or 10 pieces of script are Chinese characters of 16 can show that 10 pieces of script are English letters of 24 too or can show that about 7 pieces of script are Chinese characters of 24 3 Click OK to place and position the Alarm Bar where desi
6. Periodical JOG Set at window close Periodical bounce This Attribute becomes active automatically when the window is active The Inc value is added to the designated word if the result 1s not larger than Upper limit Once the upper limit 1s reached or exceeded the value returns to zero and incrementing begins again BE This Attribute becomes active automatically when the window is active The Dec value is subtracted from the designated word if the result is not less than Bottom limit Once the bottom limit 1s reached or exceeded decrementing stops Upper Limit Set value data 1s written to the designated word automatically when the window containing it is closed The function is effective for LW Local Word and LB Local Bit This Attribute becomes active automatically when the window is active The Inc value is added to the value of the designated word until the Upper limit is reached Then the Inc value is subtracted from the designated word until zero 1s reached This cycle is repeated until the window becomes inactive LM vac P p NO This Attribute becomes active automatically when the window is active The value is incremented by 1 at regular intervals as specified by the Break time until the High limit is reached Then the value is reset to the Low limit
7. PLC station nn Multiple HMI HHI HMI link speed Connect IF Serial cs aste e b ud Local IP address server IP address subnetwork mask Default route IP address PLC tme out constant sec 3 PLC block pack There are seven tabs in the dialog PLC General Indicator Security Editor Hard ware and Auxiliary We introduce them one by one 7 1 The PLC Tab system Parameter Setting General Indicator Security Editor PLC type jj I MUR HMI model MTS10TAMTSOST 640 x 480 PLC LF port BS 465 default Data bits 7 Bits stop bits 1 Bit lt Parameter 1 LI c f Parameter 3 Parameter 5 HMI station no Multiple HMI Master HHMI HMI link speed lt Connect IF Serial 4 S E Zu T A zi 1 AWE i server IP address Default route IP address PLC tme out constant sec e Cancel PLC type Select the type of PLC from available PLC selection menu p FROnFK2 v MITSUBISHI em MITSUBISHI FXZn Dibith PD v1 00 MITSUBISHI IZ 51Utl MODBUS ETU Modbus R TU Extend FOS V 3 02 MODBUS ETU server MODBUS RTU TC MODE PDs 1 00 MODBUS ETU TCPAP MODBUS RTU G485 ZW OMRON OMRON CILACSI PDS V201 OMRON ESCH FDS 1 01 OMRON 465 ZW F MAC sAIA PCD POU Mode PDS v1 00 sAIA FCD S BUS Mode FDS v1 00 samsung sPC 1L SHARP IW Senes POS V1 0 SIEMENS 57 220
8. Rac Button SYS Shape Shape Background 5 JE Frame 5 E Select Lib Unattach Lib Delete Shape Place Close 5 10 Bitmap Libraries 1 On Library menu select Bitmap select Call up Library 2 Click on the Add bitmap button the following dialog box pops up Fill in cell no Bitmap no to save imported graphics assign a name up to 8 characters to the bitmap and enter the number of states the bitmap 1s to have Import Hitmap Bitmap Bitmap No v Bitmap name Total states Cancel All states must be assigned a bitmap When done click on Next button dL ret Hitmap Graphics Bitmap lile CAEBSUIV lengiLibrangtb brgp State N Width T3 Height T9 Size 647 0b tes Calaorg 256 Transparent 0 Hack Next Cancer Gel Hitmap Graphics Bitmap lile CAEBSUIV FU engiLibranglaa brmqp State Width T3 Height 75 Size Baz Ob tes Colors 256 Transparent 0 Hack finished Cancer Push Finished such a Shape with 2 kinds of states is added to Shape Library Several points about Get Bitmap Graphics the communication frame are explained 1 One color of the bitmap can be selected as transparent To make a color transparent simply select the Transparent check mark and then click anywhere in the area to be made transparent Get Bitmap Graphics Bitmap file CAEB5001V270eng LibranA2 bmp State 0 Width 2
9. Save As Save in Project EBremplate5 n EBremplate5 p EBtemplateSo t EBtemplatesd tp EBtemplates20 EBtemplatesz0p Save as type EasvBuilder Files epi Ww Click Save 4 In the menu bar select Tools Compile it will pop up a compiling message box After compiling click Close to close the message box Compiling Project name C Documents and Settings poyi DesktopW2 O Project a epj Window Help Compile file name C Documents and Settings poyi DesktopW270 Project a cob Compile On line Simulation 0 error Off line Simulation Program size 2216 6 bytes Download Object size 2852 bytes Library size 65556 bytes Total size 290084 bytes Macro Compress Uncompress Decompile 5 In the menu bar select Tools Off line simulation for PC to simulate the PLC and emulate operations At this time we can see the new blank project we just created on the simulation screen as below EasyView ieee Window Help Compile On line Simulation OFF line Simulation Download Macro CompressiLincoampress Decompile There s no object on the screen and it doesn t allow to be executed any operations On this screen right Click the mouse and select Exit or press Space key to exit the simulation screen E EasyBuilder 500 User s Manual 2 2 Create a Toggle Switch Object Next step we add a switch object on the project
10. which displays as below Window Setting Name WINDOM 011 Window no Start Pos x ll Size Width 640 Height 480 Style Tracking Monopoly Clipping Coherence security level Lowest Underlay window 1 None Frame Width 4 Background Color MEE Pattern Filled Pattern color is Note Security level is only valid for base window but not for other windows There are 3 levels in a project Level 0 is the lowest level of security all have access to these windows regardless of the password Level 1 is a middle level allowing access to level 1 and level 0 windows Level 2 is the highest level of security and can access all levels For example we can set the security of the most important switches as highest level so that general users are not allowed to access these important switches Here we take an example of security level Select File New to create a new project Check Security Control from Edit System parameters Security and then set the passwords for di fferent 3 levels 1111 is given to level 1 system Parameter Setting General Indicator Security Editor Password Level D Levdi 111 Levelz 2222 System register LW9042 displays the security level of the active base window and just can be read out not be written in Create a Numeric Data object and place it on window 10 to display the current security level showed a s below Create Nu
11. 1 First in menu bar select Edit System Parameters the System Parameters Setting popup dialog appears System Parameter Setting PLC General Indicator Security Editor Hardware Aux PLC type AEA v HMI model MT510T MTS508T 640 x 480 v PLC I F port R5 485 4w v Baud rate Data bits 7 Bits E Parity Stop bits 1 Bit B Parameter 1 Turn around delay Parameter 3 Parameter 4 Parameter 5 Parameter 6 HMI station no 0 PLC station no 0 Multiple HMI Master HMI HMI link speed 115200 Connect I F Serial Local IP address Server IP address Subnetwork mask Default route IP address PLC time out constant sec 30 w PLC block pack In this example we choose PLC type as MITSUBISHI FXOn FX2 Select corresponding HMI model you are using 2 In the menu select Tools Toggle Switch or click amp icon the popup Toggle Switch attributes dialog appears as follows Toggle Switch Object s Attributes Library Tools Wind General Shape Label Profile Description Bit Lamp Read address Word Lamp Device type LB v Device address 0 Set Bit Set Word Write address Device type LB vy Device address 0 Toggle Switch Multistake Switch Function Kev Attribute Switch style Toggle 3 Switch to Shape Tab select Use bitmap and press Bitmap library ae EasyBuilder 500 User s Manual Create Toggle Switch Object
12. AAAAAAAAAA ie load Ow os ecce Eom Ride LF em AOO 7 8B BIB I L2 CEA KE id S gl Y 62 65 057 120 6 1 MODBUSRIU Wilh 96 Height Save compile and off line simulate to run the project We set LW9000 as 300 first so that RW IO shows the data of RW300 EasyVi iew LI 9O00 4x200 mm Then we input ABCDEFGHIJ into 4x200 and press save You will find ihe data of RWIO is the same as the data of 4x200 which means the upload succeed RA IO LWI O ABCDEFGHI J 388 4x200 ABCDEFGHI J How could we download 5 continuous data after RW300 to the 5 continuous locations after 4x200 We add a recipe transfer object on the project where device type is 4x device address is 200 No of word is 5 and change the direction to download Recipe Transfer Objects Attributes A Recipe Transfer Objects Attributes General Shape Label Profile General Shape pm 7 ssi Write address Colo Font 16 v No of words Awe Bold Italic Attribute Content Direction Doviiol Use label Use Label Library Tracking Label Library Duplicate this label to other states The following is the complete project Qi EeeyBinn EBPrjl epj Window 10 Initial Screen EB Fil ev On e su men ar v A Per 320 fied EB rer ot 100 96 v Language 0 i S gy er oh CDD ND lt Ade A 6 Common Window iS 10 Initial Screen ES BEL MCEEBe
13. Bitmap L9 Bj Lead Dj D eg i RW 2 Select Use shape click on Shape Library Shape Library Shape library State Lej L2 JC JL Es Le Lr JLe Js oaza 1 118 18 17 IL AL 8 Untitled 9 Untitled 10 Untitled 11 Untitled QOO 12 Untitled 13 Untitled 14 Untitled 15 Untitled Background Frame Select Lib Unattach Lib Delete Shape Place CANCEL 3 The shape browser wills pop up Select a shape click O K Create Hit Lamp Object General shape shape library Use shape Bitmap library Use bitmap Log Ed ee e 9 5j 0 RJ Click OK the shape will show on the object s position FaxyHed rr EHTi Ride I Da EE Fie Eli View Sytem Drar foot bilar Ib Window ep 1 cr hd m e arty A A F WM SH aem 5xB 2 g700X LanguagB U1 2 34 5 amp rf 8B 8 WW We 13 14 15 TE 17 18 18 ZU 71 ee 23 Z4 25 b d ZB zc 30 31 Sisi B v k A Fast J zi Li Troia een BL D LEDWBotMen Lasse FER TEL EFP sa Od 2 L4 ENNUNLUes e Ego A oe amp bl Seas RES RE BBR ROVERS S Saas ea MITSUBISHI FAO The shapes are stored in a specified shape library slb file A maximum of 20 shape libraries can be attached to a project By calling up different shape libraries useful shapes for almost any application can be found Users can also build up their own shape library Allows the background field of the library objects to be changed This is used
14. Common VWWindow 640 430 New Window 10 Initial Screen 640 430 11 WINDOW 011 640 430 50 NumKeypad1 209 273 5 NumKeypad 2 209 273 Select Window Style Fast Selection Common Window Close Task Button Selecting appropriate types of window pops up window properties dialog Base window is selected here Or right click directly on an undefined window number in the Treebar to create a new window as the graph below Laspiur IB Prjl ep Wiemdow 10 Initial Screen OO Ae Dd vum Gen Gro Pate L say Pech Wires Hee D ar A Pmn itTW a t RM CH ewe ugB E P B Wm m E OTF 34 5 amp PF o 3 3 T i 73 4 15 36 17 38 19 290 21 22 3 24 25 26 2 209 29 wD See O amp a a E EE d i oa a n i ENNSIUSLFH45SUZe ig a osrEIEIIEIggmg 1 1 K 1 1 iF 18 5 Hi 41 ix z TELJ The popup dialog of window properties shows as follows Wir Ir enn SETTE Mame Ua ae Windaw n Start Pas M D Size Width Height 480 Style Tracking L Monopoly Clipping Coherence Security evel lowest w Underlay window 1 None Frame Width 4 Dackground Color es Pattem Filled Pattern color Cancel Fill in all properties and then click OK 4 4 Opening Windows After a window is created with the open window dialog box select it from the list and double click it or press Open to open the window The windows with an mark are already opened O
15. General Shape Label Write address Device type L Device address os Inc value Ms LW Easy View internal memory LB 0 9999 Local Bit e ae amet 0 F index address of recipe memory Bit RB Jh 4005h h 0 F absolute address of recipe memory h 0 F absolute address of Master HMI s recipe memory The RB is mapping to the same area as the RW for example RB50 RBS5F is mapping to the same location as RW5 while the LB is mapping to the different area from the LW The local memory address LB9000 LB9999 LW9000 LW9999 and RW60000 RW65535 is reserved for system use and user shall not use them as general purpose device Please refer ch 12 System Register When the recipe memory is accessed by index address the index address 1s offset from its indicated address by the content of LW9000 For examples if LW9000 50 then an index address RWI 100 physically accesses the data at address RW 150 100 50 5 5 Selecting a Shape Before select a shape has to select a shape library One shape library includes 48 shapes each shape includes maximum 32 states There are two methods to use shape One is static shape another way 1s display different object states State 0 Shape shape library A Shape State Shape 47 The static shape object methods please refer Ch 3 5 6 Selecting a shape for object 1 Click on the Shape tab Create Hit Lamp Object General shape Label shape
16. m 4 ae Y ee eee eee exe H DD d our a oe afd oh aks MA o L E Ez 4 NI t ur Kd LLLLLLLLi Ace x B T ud D eee rh d EN RN E um ur mum b NES NN RENS REN GE GLO CR HN NEN SE NEN S im 5 um i E a dh d LE t ee Y P eo on EE ka TI b 1 il ie EN Easy View 2 Multiple pages trend display Newly build a project and save at first In editor systematic parameter in set up by correct one PLC the types and parameter Adding more than one page trend display object the institute shows that its attribute 1s set up as follows Trend Display Object s Attributes General Trend Profile Page type ii TR pars Mn of page Hold style Hold trend display Attribute Start fram right Sampling time seconds Plot point 21 Head address Device type LW Device address 0 BIN Ho af channel 4 Scrall control Device type w Device address bal Tag Hold control Device type Device address Tag It is 21 to pay attention to taking a sample and count Reading the address as LWO it is 4 that the orbit is counted in thi
17. 13 Height 59 Size 12036byte Colors 25b gun Click on Finished when final selection 1s made The graphic importer will guide you through each state to get and install BMP graphics The Back button can be used to review the entered bitmaps Bitmap Library Bitmap name Total states Compressed Image size 12035 Background 1 Frame p Select Lib n Lib Unattach Lib Lib Can see the background color of the car has already disappeared has regarded this Bitmap as static Bitmap and shown on the screen its result is as follows M EasyHwiMer EBPr Window 10 Initial ereta fe fol EB Fl Bib Yew Gran Pow Dum Learny Teoh Hoedoe de F D EE 2c St A77 UaM EE ear oe 003 Language M 0 te 3 4 5 b F H 8 JJ 1 12 73 14 15 16 17 1H 19 ZU Z1 ZZ Z3 z4 25 Zb z 28 ZU 309 A ae UU Y LITNEN E Fac Selec son Carat Weslcw 810 zrni Seren i 5 1i 12 13 14 15 16 Tj 15 13 ri ls ug sd a oy e arci 3 Sy EB is mk He isa is Les i i Bh a k og hip m lai om al Sab If OES Pe TE ee El fe i pr D 4 Eg Tz iz ts fs Hu epu ie mn Wee ISI MITSULDISHI FxOnF he This is useful for eliminating background colors 2 Compressed can compress this Bitmap to deal with can reduce the memory body taken up Bitmap Library fx Bitmap library bmp1 v o
18. 2 Word 1 Word The lowest Word Low order High order Low order High order Low order High order Low order byte byte byte id l1 l1 d l1 When input character AB AB The Highest Word 2 Word 1 Word The lowest Word Low order High order Low order High order Low order High order Low order byte l1 ll d oeo When input character ABC ABE The Highest Word 2 Word 1 Word The lowest Word Low order High order Low order High order Low order High order Low order byte byte idi d d d e eo 2 Attribute Adjust Choose Right When input character A A The Highest Word 2 Word 1 Word The lowest Word Low order High order Low order High order Low order High order Low order byte a ti l1 When input character AB AB The Highest Word 2 Word 1 Word The lowest Word Low order High order Low order High order Low order High order Low order byte byte 5 j l l l1 When input character ABC ABC The Highest Word 2 Word 1 Word The lowest Word High Low order High order Low order High order Low order High order Low order order byte byte byte byte byte Users are used to in the data in can show the content of introduction at the same time on the keyboard then put a text display component on the keyboard let it read the corresponding data between LW
19. 6 4 Set Bit Object 6 5 Set Word object 6 11 Numeric Data Object Example 2 A popup window with a keypad In many situations we need to input the data to the register If we place the keyboard on the active window not only 1s it too dull to be artistic but it also eliminates the space for designing the active display We use a popup direct window for solving this problem well If we would like to input data to the LWO 1 Create a numeric input extend object set Device type for LW Device address for 0 Trigger device for LB and address for 9000 Create Humeric Input Extend Object ww Device address S000 Winrar Sek Te Nome TTA Windowna 11 SanPas X 0 size c a zm Widih 180 Height 198 Style Tracking Monopoly Clipping C Coherence Security evel Lowest Underlay window e 1 None Y 2 None Y None Frame Width Color Tel Background Colo es Pace Filled Pattern color es ae ere 3 Edit window 11 place a keypad in the middle of the window latAludides FR rj Whedew 11 WINDOW Bull On Fie Fd Wem Coton Drwe Paz Urey Toda Winder Hep i OSG 980 8TsW a x 5H O sow s ua Fa A y i LM b i EU x d ond E 12345 87 8 3 N11 12 3 M I5 36 I7 30 19 20 21 22 22 74 25 28 27 22 22 00 0 Fasie Ho c Bos a un ratu tae Lopr OnD ez we msszqzgagsgs3s a ai E ii 13 n 1E i iW if 4 Create a direct window object Device
20. Bit PLC PLC bit Word The Address Type show different PLC address type and range Usually there are 4 data types Bit Byte Word Double Word 1 Bit address type LB Local Bit Internal bit of the HMI EasyBuilder 500 User s Manual RBI Recipe index bit Please refer the ch 8 RB Recipe bit Ms RB Master Slave connect the Slave HMI can use Ms RB to get the Master HMI s RB data Ms LB Master Slave connect the Slave HMI can use Ms LB to get the Master HMI s LB data ddd Decimal address format 000 Octal address format hhh Hexadecimal address format ddd h ddd word address in decimal format h bit address 1n hexadecimal format ddd dd ddd word address 1n decimal format dd bit address 1n decimal format ddd o ddd word address in decimal format o bit address in decimal format Some PLC base address are 1 For example Modbus RTU 1x and Ox address range is from to 327767 Some Modbus RTU device base address 1s O So the MT500 address have to subtract 1 to according the device address Mitsubishi FX2n SM address type base address 1s 8000 Max and Min to mean maximum address number and minimum address number 2 Byte address type Byte address has 2 types ddd and hhh ddd byte address 1n decimal format hhh byte address in hexadecimal format Max and Min to mean maximum address number and minimum address number 3 Word address type LW Local Word the data in HMI memory When the HMI power off
21. Print Preview Print Setup la 2 EBPril 3 templateS20p 4 A SCIIFont Exil All current windows are closed after clicking Close the display shows as below m Faal n E Dub NRO eH SF PE EE See 65s SN Mites S FONT 16 A 2 fay WARUM Des FS GP ee He eS awe 8 72 Pate Pritt mira he PARANA 9720707 m toes Be rn cdm BERE DS Reet CIAR TT TERSBREC ERT ERE REPENS OR Tes 4 Save Select Save from the File menu or select Il to save the current project The dialog shows as below if the project hasn t been saved File Edit View Option Draw Part Save As New Ctrl M Open Ctra Save in 29 Project d E Ej Clase EBa EBremplate52n Cu EBEBPrjl EBtemplateSz2 p Bevel Nore EBtemplate5 Print Object Summary Ctrl F EB template500p Print Preview EBtemplate5 6t Print Setup EBremplates btp la 2 EBPrjl 4 A SCIIFant i es Save as type EasyBuilder Files epi Exil Input the file s name and click Save EasyBuilder 500 User s Manual If the project is saved before click Save and there isn t any dialog showed 5 Saveas Select Save as in the File menu to save the current project to designate path File Edit View Option Draw Park Save As Mew Ctrl M F E Open Ctrl g save in Fr ius p Close EBa EEtemplate520 Save Ctrl s EBEBPrj1 EBtemplate520p EBtemplatesoo Print Object Summary Ctrl P pestonpiates pup Print Preview EBte
22. Undo Cancel the latest action Redo Return to the previous condition Print Print About EB500 Detail of EB500 Version Help Perfecting Redraw Redraw Window EasyBuilder 500 User s Manual Grid Set grid on the screen Snap Enable the snapping of objects to the grid Save Objects to Shape Library Save Objects to Shape Library Call up Shape Library Call up Shape Library Call up Bitmap library Call up Bitmap library Save to Group Library Save to Group Library Call up Group Library Call up Group Library Compile Compile project On line Simulation On line simulation Off line Simulation Off line simulation Download Download project State bar Change the state of the object 2 Manager Toolbar Font Choose the size of the font Font enlarging Enlarge the font Font shrinks Reduce the font Align Left When the content of the text exceeds 2 lines the text 1s put according to the left align way Center When the content of the text exceeds 2 lines the text is put according to the center align way Align Right When the content of the text exceeds 2 lines the text is put according to the Right align way Top Layer Set up object and lie in top layer Bottom Layer Set up object and lie in Bottom layer Previous Layer Set up object to Previous Layer Next Layer Set up object to Next Layer Nudge Up Make object Nudge Up Nudge Down Make object Nudge Down Nu
23. displayed on the upper level if it is touched However if you mark it as Coherence even if you touch it it doesn t go to the up level and cohere to it s calling window Note The window number is not changeable after a window is created but name frame and background are changeable Base Window Base Window Security Set the corresponding security level to prevent unauthorized access to windows See Ch10 Security for further details Underlay window Set up corresponding Underlay Window in the present window Underlay window is set only for created window Generally speaking shared objects can be put on it Frame It s suggested to choose frame for popup window The width of the frame can be selected 0 4 6 8 10 12 14 16 If the Frame is not set to 0 8 colors are available for the frame Background Select the background color and pattern for the window Modifying window properties 1 Select Open Window from the window menu Highlight the target window click on Setting to change the properties 2 Right click the selected window from the window Treebar and choose setting 4 3 Creating New Windows In the window menu select the Open Window command New window Select the window type Base Window or Fast selection or Common Window to create a new window or right click on an undefined window number in the Treebar and then select Create Open Window Nao Window name Size Fast Selection 100 448
24. set style Sub value TOCG b eet style Add value JO b De ie Botomiimt 0 Tne valne Weedut LW9000 reduce Superpose LWO to reduce LW9000 add Superpose LWO to add Thus when we look up the recipe data the value of LWO changes and display the current recipe data Then we place a keypad add some context for embellishment One project is done as below Ww EasyBuilder Ai5fSdR epi Window 10 Initial Screen SEE EB File Edit View Option Draw Parts Library Tools Window Help 8 x Dee 5 Peete BPN w BBE 29 s b B B ame A me 100 v Language 0 v FONT 24 AK EZB BLEG A HEA Ee A do om oh Bele uuu Ad d 0 1 2 34 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 State 0 v S 10 Initial Screen The current recipe data is Prep H E D RWIO B9000 Bott NE O RWI4 LE9000 T GE 4E_1 4x100 LB9000 Recipe name GAS oe aE 0 E 9 T LH90600 reduce el t l n RP 1 4x100 nQA08808f HHH pk ell ee SW_OM W9000 LHO to reduce SW_1 L W9000 ND Od WO RHIO HIS SW_2 L WO AE 1 RP_1 9H S LH9000 add LHO to add D a os eixiuHe FEK L E He r4 pd pd olg i BIB BIB mo BO d sS D ul es q dq eS SS 3 Q0 J Ch un dU b o7 Ch Vn 4 o b 0 AAR AAR AAR AAR AARAAR MODBUS RTU Save compile and off line simulation to run the project EasyView The current recipe data is A Recipe nane Data LW9666 redu
25. 1 x 0 0 s O e 2047 f 0 The positive number is infinitely great s 1 e 2047 f 0 The negative number is infinitely great s 0 or 1 e 2047 f 0 NaN Not a number The form above 1s according to IEEE754 standard the mode of the algorithm is appointed by the standard of IEEE binary scale floating dot arithmetic Font attribute Can appoint the size that number value show with the color and align the way here Available font sizes include 8 16 24 32 48 64 72 and 96 The Align is only for decimal format Create Numeric Input Extend Object E a General Mumeric Shape Fant Attribute Color Font 24 Align RightAdiust Content rsss If the form shown is set up for the above figure number of the decimal point 5 figure number under the decimal point O the number value read is 123 there are several kinds as follows of forms shown Right Adjust 12245 Left Adjust Je 205 Leading Zero 00123 6 11 Numeric Data EEE j Numeric Data Part displays the current reading of a designated PLC register data Data is displayed as text no shape or bitmap can be associated with this part 1234 Procedure to place a Numeric Data 1 Click Numeric Data icon LJ Create Numeric Data Object General Numeric Font Description Read address Device type Lw v Device address fo BIN v No af wards I v n TI gy m Ans 2 Fill in Gener
26. 10 Head address Em Device type Device address Ha af channel E Page type Select Single page Single page is a simple trend display which displays the data selected from the active screen and don t reserve the historical data Sampling time Time between point plots in seconds Plot point the number of sample points displayed across the length of the chart Read address Specify the PLC word address of the first Trend data pen the second Trend data pen starts at read address 1 and the third starts at read address 2 etc No of Channel The number of PLC data words retrieved 1s the same as No of Channel one word per channel 3 Fill in the Trend Tab Select the Channel to view each channel s settings Create Trend Display Object p General Trend Description Channel EMEN Pen attribute color Value j Zero Span 2 aK tance Description A reference name that you assign to the Trend Display not displayed Channel Can choose any channel to set up it Choose 0 to choose the Ist channel promptly choose to be article 2 analogize sequentially Pen attribute Specify the Trend Color and pen thickness for the channel Value Set the zero and span for each channel 4 Click OK to position and resize the Trend Display Procedure to add a Multiple pages Trend Display 1 Click Trend Display icon 2 Fill in General Tab Items Create Trend Display Object E
27. 1s 1t carry out one read order spend 50 millisecond to suppose respectively probably 150 millisecond read these data to want flowers in these words and when PLC data package is set up as 1 it only needs one to read the order the data that and just read more 7 byteses after ordering to extend to read these data probably need 50 7 2 2 78 millisecond comes to read these data It is obvious when data are the more use communication time that continuous PLC address can be economized 1s the more 7 2 The General Tab oy stem Parameter Setting PLC General Indicator Security Editor Hardware Aux Task button Background color Tour arm bar Pixels per scroll scroll speed No of windows Password startup window na Back light saver Cursor color Buzzer Common window Popup window Ate Extra no of event EIC source Intemal ETC T Print Printer Print sequence number Print time tag Extended time foxmat D H M Print date tag Extended date format Y Me No error detection v Message board window No D 10 1909 0 Task button The Task button is used to pop up the Fast Selection window or display the Task Bar Attribute Enables or disables the task button If disabled the Fast Selection window and Task Bar are not available at run time the default is enable for a new project Position The Task buttons can be located on the rig
28. CPU indicator is a percentage bar graph that shows system resource usage Attribute Enables or disables this feature If disabled the CPU indicator is not displayed at run time Color Set the color of the displayed CPU indicator Alarm indicator The Alarm indicator comes on when there are alarms present This indicator is a bar graph that increases when the number of alarms increases Attribute Enables or disables this feature If disabled the CPU indicator is not displayed at run time Color Set the color of the displayed CPU indicator 7 4 The Security Tab Please refer to Ch 10 Security Level 7 5 The Editor Tab system Parameter Setting PLC General Indicator Security Editor Hardware Aux Begining window no S Compiler level Level 1 Pact layout Nature Address mode Standard Language Times New Roman Language 1 Times New Roman Language 2 Times New Roman Language 5 Times New Roman Beginning window No Set the window numbering starting at 1 or 10 Internally EasyBuilder maintains the initial window of 10 but displays all window numbers with an offset so they appear to Start with an initial window of 10 Compiler level Determine the compile type Level 0 Don t check the validity of the device address when compiling Level 1 Check the validity of the device address when compiling For example Mitsubishi the CV2 of Fx 2n is display
29. D v size Width 540 Height 480 Style Tracking Monopoly Clipping L Coherence security level Lowest Underlay window i Pattern is Filled Pattern color Iz As showed above assign the window as an underlay window by selecting the underlay window property Underlay window is different from base window The component of the window of ground floor 1s inserted to the general window while operating but this window does not show in fact It is the same as the component of the general window that its component shows and controls etc Screen Window relationship A screen includes common window base window and fast window a common window or a base window includes several popup windows EasyView Window 6 Common Window Base Window 10 a Ka RM M r A i au Et When carry out Changing Window command will remove all windows on the screen including the popup windows and switch the window going to be displayed The common window is always active The popup windows coming from direct or indirect windows don t change the original content and are only attached to the base window Maximum three underlay windows are available in window setting dialog When editing a base window range of window numbers is from 10 to 1999 display shows all objects on the window At the same time if there is an underlay window under the base window the base window shows all o
30. D esny lb Winia Hei Cael tees BTW amp Fi x alu Bea oum gt And mi 5e Lnmpzsg PRS OA mod SO NI i u u ut z324 528 8 5 1 15 13 14 15 15 17 18 1 78 21 27 3 74 5 75 77 78 73 Se 9 CE k l 4 Fat eri Syy i ads l f dL EU Lir eTex 3 LI i PH LL i Yong Lecco poxdlz umo ECCO LCR A TENGEFU UIT A BOOCCS 8000040 e a LELLELEE UAT aL viBODOOE LE Lm SLES LE EO Bea LS eT d I GOS re n L ET i mh i j 1 EJ The X vector is 4 and the Y vector is 3 The addresses from top to down are Y1 Y5 and Y9 5 Window Copy EB500 supports the window copy function not only within a project but also among different projects For example As the diagram there are two windows in a project EasyBuilder 500 User s Manual FILTER IT ADEM WHEW O11 EB is Ede Wess Cet Cree Puis liey Tice Wave Hep O or Mi m ki WI 344 Fi Y al ke EH gl uL Eel A A n 1 Lib Languags Het 345 8 8 3 N d MM m wig mas RPMS AT msg X sume om ee ae L Hoe d Lu apdo o a o Do BRENT NE EB mi Cot Wee Don Dee Cati DEmy Toc hra Heb D m m ri 7 EF 4 Fi X i it ER zl E E A AH i moi Langes ott 34 5 amp BH S id 1 17 13 34 15 15 17 dH 1 78 21 7 73 24 75 7 amp 77 B S9 339 0 Sic 8 E k f E Common i i I Aa Select Window Copy from Edit menu the pop up dialog box appears as below Window Copy Snurce project CAEBSOOW2 7 0 Proje
31. Do Cie dd Y i E LI D0DERecC 2 nisu then click Redo Note Considering the size of the file only the lastest action can be Undo Redo 3 Cut Copy Paste and Delete Cut Copy Paste and Delete functions are available for all objects The corresponding icons are JEI 4 Multi Copy Multi Copy duplicates one object to many and arrange them in a certain way Choose an object and select Multi Copy from the Edit menu The popup dialog appears as below EasyBuilder 500 User s Manual Multi Copy Pitch Interval RGT X distance 30 Y Distance 30 Quantity X Quantity Y 3 Adjust distance 3 Cancel Pitch The duplicates object 1s overlaps Interval The space between duplicated objects 1s the X and Y distance RGT BTM The address type of duplicates is copied from left to right one row at a time X Horizontal Distance Y Vertical Distance The space of the duplicates are X and Y distance apart Quantity X Y The replica object is in x y quantity of the direction Address Distance This value adjusts how much the object s Address is incremented for each duplicated object Example Choose an object FOI IESEEI JR Wiedew 10 Initial SE EB File Cot Wee Cote Gree Porto LEwy Todas inde Pec Pao i Ham BTW J za EH gem AANA B iwis Langue S308 THRs a ut 7 34 5 E B W r 34 75 35 31 d3 1 708 2 77 ZI 74 75 25 27 58 79 X8 heir OOF
32. General Shape Label Shape Shape library Use shape Bitmap GG GG wm After pop up a Bitmap library dialog press Select Library Bitmap Library Bitmap library wa BOOTH Bitmap name E OSS Button T SYS Button 2 SY8 Button 3 SYS Button Total states NE m n um Compressed a d Image size 0 D 0 D Background i5 L Frame iz A Select appropriate Bitmap library We choose bmpl blb here and click Open File name ics Files of type Bitmap lib blb wv The pop up dialog shows as below Select the bitmapl and click OK Bitmap Library Bitmap library bmp Bitmap name 0 Total states Compressed LI Image size 3136 1958 Background i Frame prz A Return to Shape Tab dialog and press OK Create Toggle Switch Object General Shape Label Shape C Use shape Bitmap Use bitmap 0 1 2 3 4 5 State 0 Left Click the mouse to pull the object in to the screen as below be EasyDuilder IDPrjf Window 10 Initial EB l ile Edt vew Opbo Oraw Puts L oo Screen Took Window eb Livary Doi ih Bre a 7 x a E Pound aAA amp 100 v Language v ane BEI s 012 34 5 amp 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 State 0 v k w e y me k 1 W Cl 5 O 9 amp c B k A kk iw ER au zs o J m 5 a a RH 3 06 89 184 167 MITSUBISHI FXon FX2 width 7
33. J 1 2 JL3 JL 4 L5 Bitmap name 44 Total states Compressed Image size l P474 Background Frame J Select Lib Unattach Lib Add Bitmap Delete Bitmap The example figure shows after being compressed as above its size turns from 12036 Byte into 7474 Byte Certainly the space taken up after some figures are compressed becomes great instead should not compress this component at this moment 3 Bitmap introduced is limited as follows Its several colors support 2 colors 16 colors or 256 colors The size of the figure introduced can t exceed 640 480 W H Bitmap Library Bitmap library we BEGG ompr oro Button n Ene shape Bitmap name cm 0 35 Button 1 8YS Button 2 8Y8 Button 3 8YS Button Total states n n n 4 Compressed d d Image size 0 D D 0 Background b l Frame i5 7 Bitmap Library SYS Button and SYS Shape is system library 5 11 Group Library Group Libraries enable multiple parts and drawing objects to be combined and saved and then called up whenever necessary The Group objects saved in these libraries can be viewed and selected using the Browser function Since groups of objects may include parts that refer to Shape or Bitmap graphics the related Shape and Bitmap libraries must be attached to the project before calling up group objects Click on the Select Lib button A Standard Dialog B
34. Z4 75 zh 7 B zu 30 dl State D ML oa 4 Fait Zelecta wd Ceres Pus 11 F 13 14 15 15 Ir 15 13 P 21 fd 25 E uan am o Erg E pE Jeta E 13 ap D OG For Help poets Fl MITSUBISHI FE aTE2 5 12 Label Library From EB500 V2 5 0 add multi language function the multi language use Label Library to realize this function Please follow these step 1 Open Label Library Click menu Library Label Library open Label Library Dialog shape amp Bitmap oup P Tag 2 Setting Label Library Exon CSV Bie Inge CSV Ri State No Select the state No to display each state s context Label Name User s define Label name State No State Number range is 0 31 total 32 states Language 0 Language 3 User s define 4 different language message Add Add a label to label library Modify Modify the label that already in Label Library Delete Delete the label library Exit Exit Label Library dialog Click Add a appear the dialog Label name jte sls No of states In this dialog set the label name and total state number Click OK the Label Library will more one label Select this label click Modify The Label Content Setting dialog pop up Label Label name NON AME Change State No Tm This dialog able to edit each state each language content 3 Operating Multi Language fuction If the EB500 objects
35. as a bmp file Page Setup Set up the print format Note AI the printings are printed through Windows 7 Exit Exit the current simulation screen or press Blank key to exit the program 8 Help Open the help file 9 About The explanation of the EB500 and copyright Chapter 4 Window Operations Window is one of the most important and unique elements for EB500 Cper maqoritw windows The above example shows creating multiple windows at the same time 4 1 Window Types Window is the basic element for an EB500 project Every display is composed by many windows There are three types of windows Base Fast selection and Common The basic window can also be used as popup windows after changing the size All windows can be assigned as underlay windows Basic Window These are the normal windows that would be displayed during HMI runtime operations When using change window command to order the base window that 1s switched over will remove all display on the screen Except Common Window Fast Selection Window and then the basic window will show on the screen As object on base window can be touched off and opened popup windows the primitive information on base window will be kept at this moment Being touched off and opened popup windows will be added on base window all windows of the same situation can be regarded as the set membership Switching over from base window N to base window M all Sub window of the base win
36. different windows Since the fast selection window is global to all windows it can be called up at any time To change windows press the function key that targets the destination window This avoids the tedious search and find process The Window Bar accommodates up to six window icons Double clicking the minimize icon of a window will icon size the corresponding window Clicking it again will return the window to its original location and size Fast Selection Window Window bar The Task Button for Window bar and Fast Selection Window Task Bar can include 6 window icons at the same time at most Doubling click and minimizing icons can minimize corresponding pop up window clicking again can resume to the original state at the window in this icon Can minimize this window on Window bar when one popup window contains Minimize window and Window bar with the function key Can consult Parts Function key some content Procedure to Setup Task Buttons On Edit menu Select System Parameter Set Task button as Enable Set the position of the task buttons to the left or right side of the window Note The task buttons will be visible at run time in the lower right or left corner of the display The Task buttons are not visible when editing a window system Parameter Setting Embk w Position Right Background color SSCL Text Left adjust Alacm bar Pixels per scroll scroll speed Na of
37. has label attribute it can use Label Library The following example use Word Lamp object Create Word Lamp Object General shape Attribute Color Font 16 v kl I Bol Italic Label Index NON AME v Content Language status U Use label Tracking Label Library Duplicate this label to other states Select Use Label Library box Label Index Select the label that already define in Label Library It was enabled by selected Use Label Library box Use Label Library Select this box to enable use Label Library Label Library Click Library to open Label Library After the Word Lamp setting use System Register LW9130 to change the different language LW9130 Multi Language change LW9130 0 Display label library language O content text LW9130 1 Display label library language 1 content text LW9130 2 Display label library language 2 content text LW913023 Display label library language 3 content text LW9130 3 Still display label library language 0O content text 5 13 Tag Library Software V2 5 adds a new capability for supporting address tags This capability can translate all required addresses into specific tags In the project a tag is used to represent a particular address and users can make use of the tag library to utilize this capability Procedures of usages are described as below 1 Opening the tag library Select Library gt Tag to open the tag librar
38. modify alarm messages Alarm Scan Object Address Alarm Content 0 LBU On Alarm 1 Click Alarm Scan icon to pop up the Alarm Scan Object message summary screen 2 Click on the Add button to add a new message or click on the Setting button to modify an existing message Fill in the Attributes Dialog Alarm Scan Object s Attributes Head address Attribute Alarm On C Off Category 0 Content Alarm Color mum Font 18 Label Library Read Address specifies the PLC bit address that triggers the message Alarm attribute ON displays this message when the bit is ON OFF displays this message when the bit is OFF Category Reserved Content Enter the message Content text text Color and Font size The default font is 16 3 Click OK the message appears in Alarm Scan message summary box In order to take full use of communication bandwidth it 1s recommended that a block of continuous PLC bit devices be used for the Alarm Scan list For example Use Bits 100 to 199 to control the display of all alarm Messages so that one read command retrieves Bits 100 to 199 all at once instead of one bit at a time 6 19 Alarm Display s Waming information shows that the component will show al waming information touched off in a the area that is established A content shown is the same for the content and reporting to the police that its shows are dl the waming information about a certa
39. on Ch 11 Back light control write back Turns the display s backlight OFF when the Read address turns ON Whenever the backlight is turned OFF through PLC control or time out the HMI turns the Read address bit OFF in the PLC When the backlight is OFF a touch reactivates the backlight PLC Control Objects AHributes Description Head address Device type v Device address 0 Attribute Type of control ETE UEA ot C c ET Macro name As the example above when the LB3 turns to ON backlight is off and LB3 is given the order of OFF When the user touches the screen the backlight turns to ON but LB3 is still OFF Write Data to PLC current base window Can use this to operate when PLC wants to know the serial number of the present basic window The data content of PLC 1s serial numbers of the present basic window to deserve and operate returning and giving Notice When switch over the basic window the touch sensitive screen will convey the present basic window serial number to the designated word address automatically PLC Control Ohject s AHributes Description Head address Device type v Device address 0 Attribute Type of control rite data to Pl C current base window Macro name uch as pursueing when one PLC set up as above controls object will preserve the serial number of present base window in word address LWO General PLC Control This control is us
40. rectangle circle arc polygon bitmap and so on o Cursor Position Shows the current cursor position on the active screen and assistant statements 3 5 2 Menu File 1 New EasyBuilder 500 User s Manual Select New from File menu or select LJ to create a new project Edit view Option Open Close Save Save OS Print Object Summary Print Preview Print Setup la 2 EBPrii 3 template5z2 p 4 ASCIIFant Exil ime cun EasyBuilder Ctrl M Chro Welcome to EasyBuilder 500 Lip eine Please select your model s Ctrl P gt Model CIMA Language Single Byte Click OK a new project is initiated 2 Open Select Open from File menu or select 2 to open a exist project Edit View Option Mew Open Close Save Save Os Print Objeck Summary Print Preview Print Setup la 2 EBPrii 3 templateS20p 4 A5CTIFont Exil Draw Park Ctrl M EU Look in 9 d pm EBs EBtemplateseo EBEEPrjt EBremplate5z p EBtemplatesoo EBtemplateSO0p Ctrl F EBtemplate506t EB template506tp Chri 5 File name Files of type EasyBuilder Files epi v Choose the selected project file and then click Open or double click that project file 3 Close Select Close from File menu to close the current project EasyBuilder 500 User s Manual Edit View Option Draw Park Mew Ctrl M Open Chrl 0 Save Ckri 5 Save As Print Object Summary Ctrl F
41. single object 2 Select All Objects Select the all objects on the screen 3 Select Next Object Select the object under the selected object Cancel the selected object If many objects are selected and you would like to cancel some of them move the mouse to the object press Ctrl key and then click that object to cancel the selection Add the object If many objects are selected and you would like to add another object move the mouse to the object you are adding press Ctrl key and then click that object to add the selection NOTE Many objects or states are selected just move the mouse and select someone of the object press Ctrl key and then click that object to be selected 14 Change Attribute Double click on the object or click on the Edit icon Sy to call up its Attribute Dialog for editing 15 Change the size of the object By double clicking the object the dialog of the object s attribute appears Select Profile to change the size of the object or by dragging the corresponding points to resize the object 3 5 4 Menu View In View menu each selection controls the display of each toolbar Basically each function in the toolbar can be found in corresponding menu 1 Standard Toolbar SA anlar D bl As the diagram above the functions to the corresponding icons are New Create a new object Open Open a existing project Save Save the current project Cut Cut Copy Duplicate Paste Paste
42. the following two points Can t there is conflict of addresses with the project object in the designed storage area 2 Storage area can exceed RW60000 RW60000 the above reserve for system How to expand the storage area can the user see Eventlog information of more clauses and subclauses In systematic parameter generally Extra no of event in input it 1000 show picture system Parameter Setting Task button Attribute Background color d larm bar Pixels per scroll scroll speed No of windows Password startup window na v Back light saver Cursor calor Jl Buzzer Enable Common window Popup window Attribute Below base screen Extra no of event 1000 RIC source Internal RTC Print Printer Mone wi Print sequence number C Print time tag J Extended time format D H M Print date tag Extended date format Y M D No error detection Message board window No 0 10 1999 0 sd Add 200 Eventlogs of systematic acquiescence there are 1200 Eventlogs altogether the memory space taken up is expanded to 1200 20 30 2430 words Ch 8 Recipe Transfer The Recipe Transfer part activates the transfer of a block of contiguous registers from the HMI to the PLC or from the PLC to the HMI HMI storage address is determined by an internal word For MT500 64K is selected to store the recipe data 8 1 Procedure to create a Recipe Transfer Part 1 Click the Recipe Transfe
43. the programmer to turn off the buzzer Common Window Popup window Determines where an popup window called from the common window is displayed Typically The Popup window is displayed on the top layer Attribute Determines the location of the Common window above or below the base screen Extra No of Event Normally 200 events are stored in the Event Log If more than 200 events are needed the additional amount is entered here If 1200 events are need 1000 is inputted here Up to 2800 additional logs can be added RTC source Establish the source of the clock when the unusual incident emerges RTC data can be got from PLC or inside RTC If choose to get from PLC is it set up one data transmission component come to transmit from PLC actual RTC datum reach to corresponding LW address cycle to need then can consult the content of reserving the register address systematically relevantly If choose inside RTC must then at CPU board card Recipe card which can be selected for use in installation Print Use these settings to set the Printer protocol Print time and print sequence number can be printed at the same time Printer Select the printer drivers Print Sequence number Select to print the sequence number of the event along with the event occurrence The number increases for each new event Print time tag Print the time along with the printed information Extended time format D H M Change the time format in the t
44. time tag Extended time foxmat D H M Print date taz Extended date format Y MD No error detection Message board window No 0 10 1999 Appl Operation mode the thickness of the pen color and clear board can be set from Function Key Message Board Create Function Key Object Creneval shape ENT O B3 Q CLE ESC C ASCII CO Hard copy O Change window CO Return to previous CO Change common window Popup window Close window O JOG Fevindow O Window bar CO Minimize window Mesage boari 5 aaa et i oper ahon mode met pen style set pen color lear board Functions of the Message Board explain as follows Set Operation Mode Attributes Operation mode Brush Clip Pen Used for drawing graphics or text on the Message Board window Brush Used as an eraser to erase lines drawn by the pen Clip Allows the operator to drag a rectangle around an area When the operator stops touching the screen the area in the rectangle is erased Set pen style Set pen style is used to select the pen thickness Attributes Line width 1 EL A EL Set pen color Set pen color is used to select the color of lines drawn on the Message window Attributes Pen color color iE Clear board Erases the entire Message window Example Select File New to create a new project from EB500 Create window 11 and wi
45. type for LB Device address for 9069 In size width for 180 and height for 180 ELLIIJ Direct Window Objects Attributes Direct Window Objects Attributes Geren Profi Ganas Profile Lecce Piritan Aami Sihari Fira Deita type LB Sire Laaluiiders ERE ih Windies 10 Initial ESTEE 11 EB Fle Fat Wess Ceti Cree Parts d vay Tack Eria fep O or e a amp P ri 20 M EE al i Ft A QS TR i Lii 5 angun 5 Save compile and Off line simulation to run the project 6 When clicking on the numeric input extend object to input LWO a popup keypad appears under the object After inputting the keypad disappears Reference Ch 13 System Bit and Register address B9000 LB9069 Note In EB500 there is a default 2 digit keypad 4 6 Windows related object Directly related function keys of windows Change Window Return to Previous Change Common Window Popup Window Jog FS Window Related function keys of direct window Direct and Indirect window Please refer to corresponding content of Parts 4 7 Resource allocation of windows MT500 uses static distribution memory to allocate the resource Each window occupies certain fix resource Right click to select System Resource under the off line simulation to look up the distribution of the resource ll utem Resource Vina 7 Hase Window Popup Vindew T Popup Windew 350000 Popup Windew 1 1950000 Popup Sindmwi4 isidi Popup
46. up certain data to the register when initializing a project or an application We set LBO to On and LW1 to 200 when start up window 10 1 Create a Set Bit Object Device type for LB Device address for 0 Select style Set On at window open Creale Sat Bit Object General Shane Label Diese nplbog wi nbs acier Dee tne LB Dmae adress 0 trie She Sed ON a ware eger 2 Create a Set Word object Device type for LW Device address for 1 Select style Set at window open Sot Word Objects Attributes amp utibule Tei lps Del ot veridica open geb yaka ZUU 3 Create a Bit Lamp object Device type for LB Device address for 0 Select Function as Normal to display at State Q Rit Lamp Objects Attribute lt Dere odjem 0 Baring Furhign Nome Numeric Data Objects Attributes Genera Numeric Fond Profile Lecce Fiead mihai Didi type LW Desde 0 DIH iF Ha ol vende 5 The complete project shows as below IECIT IET r WHIKA TH havi kal sihti EB me Ede W i Dra Pata Livery le Wrba Hei D c Gl n aTr AA t AM SB gee zat MEX Langpeng Hott 34 5 amp BH 9 id J 17 13 34 15 1E 17 1H T9 78 71 Z7 eee PR 9 30 6S OY boo N wha i 7 1 a Past Dudes TIE I juu rmm ot 11 mE 8 L B p sg 6 Save Compile Off line simulation to run the project LBO is set for ON LW1 is set for200 Ea syVi aw Reference Ch6 1 Bit Lamp Object
47. words address type so some driver of PLC will Double word is it change to make with word user is it pay special attention to operation instructions PLC of driver to need 6 1 Bit Lamp A Bit Lamp displays the ON or OFF states of a designated PLC address If the bit status 1s OFF the state 0 shape is displayed If the bit status is ON the state 1 shape 1s displayed The corresponding label is also displayed if Use Label is enabled Procedure to place a Bit Lamp l Click Bit Lamp icon the following popup dialog displays Create Bit Lamp Object mM General Shape Label Description Read address Device type LB v Device address 0 Attribute Function Normal 2 Fill in General Tab Items Description A reference name that you assign to the Bit Lamp not displayed Read Address PLC location address of Bit Lamp Attribute Normal only the corresponding shape is displayed which doesn t blink ON Blink State 0 or 1 Show the figure of 0 as Read Address state for OFF Show the figure of as the state for ON And show the result of blinking the frequency glimmers set up from Break time 3 Click the Shape Tab Select a shape or a bitmap to display the corresponding OFF and ON states Create Bit Lamp Object General Shape Label __ Shape library Use shape Bitmap library C Use bitmap WHAHA seo 4 Goth the Label Tab and fill in Attribute and Content fileds fo
48. 3 T Eg O EI N L1 O C A i x d bsp Y 189 67 272 122 7 20 MODBUS RTU Width 84 Height When off line simulation we set LW9000 as 300 and input AAAAAAAAAA into RWIO EasyView RATIO LI9O00 AAAAAAAAAA 4x200 ee When we press the download button you will find the data is transfer m RW300 to 4x200 RNI LwW900O AAAAAAAAAA 4x200 AAAAAAAAAA Easy Uieu Pom the A p we can scan that wieder ERE ie m o PLC to retentive memory or downloading the data to PLC the starting addresses of retentive memory are all the corresponding address of LW9000 8 3 Upload Download of the recipe memory between HMI and PLC Recipe memory is very useful Take production line as an example the production facilities complete different tasks by different parameters provided Now we can save the set of data to recipe memory according to the specific format When we need them we retrieve them without inputting a plenty of data temporarily There is example below of how to conveniently retrieve several recipe data Assume that there are 10 sets of recipes each recipe is composed by 5 words including Recipe name which takes up 4 words and recipe data which takes up 1 word We arrange the recipe from RWO The Oth group RWO RW4 C ARAAAAAR 0 The 4th group EW20 RW24 EEBEEEREE 4444 The 5th group EW25 RW293 CEBBEBEBEBC 5555 The th group FAW 30
49. 6 Untitled 47 Untitled Background Frame Select Lib Unattach Lib Delete Shape Now select Using Function key to make Shape Library Window Property Grid color Display Object ID Using function key to make shape library Jump to application mode when download done Automatically save and compile when downloading or simulating Create a Function Key object under shape Select shapes and Function Key save to Shape Library D EaxyHenlber EHE 7 LUE IS E I azlza Zeaern EB Fl Bit Yee rmn Dow xu beer Tek Wundew He Cee ther o BTE 7 x 3IWIM BEB paws A AE SS 0 Language 0 See Pea ao messe i im U 1 3 45 b 7 H 9 W710 12 3 14 15 16 17 1H 19 ZU Z1 Z Z3 z4 25 Zb A 2z8 Zu 309 A ae UU Y 1 Past ikim amp Canmgmn Wiii x PU arhi Sezese II E UEU IgE l MITSULDISHI FAWPFAA The Shape Library s boundary will be equal to the Function Key s boundary but the Shape Library doesn t include the Function Key Object Shape Library Lej 1 2 JL Ls JLo JC JL L9 oaas 14 15 16 17 EP 0 Untitled 41 Untitled 42 Untitled 43 Untitled LI b ul 4 Untitled 45 Untitled 46 Untitled 7 Untitled Background 5 JE Frame 5 A select Lib Unattach Lib Delete Shape Shape Library shape library SYS Button v State button CIEE o Un TN a 10 11 12 13 14 15 16 17 Button Caption
50. 6 1958 Background s Frame iz F SelectLib Newlib Unattach Lib Allows the background field of the library objects to be changed This is used to see how a window s background color affects the way a bitmap appears The background color of the bitmap object in the library does not follow the bitmap when it is placed on the window Attach an existing library to the current project Save the Bitmap to a file with bmp format Note After create the new shape library or new shapes have to save project Otherwise the library or shapes will lost After deleting when there is Bitmap used in this Library in the procedure the corresponding position in the procedure will no longer show corresponding Bitmap but show the blank figure and even choose this Bitmap Library again the corresponding position will no longer show this Bitmap only reselect corresponding Bitmap for this component and can show Bitmap again 4 Click OK Create Hit Lamp Object General shape Label shape Tse shape Bitmap Bitmap library v Use bitmap wW 1 3 GJ GJ GJ Ww HaryHuier EHP I Lg DNI lockal Sereen EB Eb Eft Yew Option Due pat Limy Jook Window elp Dai then BY CAO f x se Me AB Ae AA ele E 100X Language FONT 16 A EEBses fy Ch 3s ARR RPA Sp Ro zm Xj Ae g F dE ai 0 12 34 5 amp 7 B8 9 1 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Stae D C x FER ELA E
51. 9 Meight 79 X404 Y 164 NM 4 In menu bar select File Save and then select Tools Compile 5 In menu bar select Tools Off line simulation When clicking the switch object you can see the on off situations like a real one EasyView 6 If you have MT5 PC please connect PLC port of MT5 PC to PLC and HMI port of MT5 PC to the PLC RS485 port of the display PC port to the PC COM Have the power openly now EasyBuilder 500 User s Manual 7 In the menu bar select Tools On line Simulation you will find by clicking the switch on your display you can control the corresponding PLC output Y 1 You can change this output status 8 In the menu bar select Tools Download Easy Download complete project C Documents and Settings poy E Downloading binary file Cancel 9 After downloading reset the HMI You can control this switch by touching the object EasyBuilder 500 User s Manual Chapter 3 Software Reference Guide EasyManager and PLCAddressView are software used for Easybuilder 500 We will introduce them one by one Ww MSN 55 Outlook Express Lye EasyBuilder 500 EN EasyManager ImagecF PLCAddressVievw Remote Assistance i P windows Media Player i Windows Messenger t ReleaseNote pdf ig Reserved Word bit pdr D Windows Movie Maker fil EasvBuilder 3 1 EasyManager Easy Manager is the comprehensive software of system of a whole set of Wein Vi
52. 9060 LW9075 Creat a new project and adding a ASCII Input Extend Object to window 10 it is set up as follows Create ASCII Input Extend Object General Shape Font Read address Device type Lw wj Device address C No of words Trigger address Create ASCII Data Object General Fort Description Read address Device type Device address 3071 Put the keyboard and this object together save compile on off line simulation or download pursue not showing its if operation result _ EasyView 22334A T 1 2 3 4 5 6 7 8 9 9 JCXGEOE ESOS f S 0 F G HI JI KIL ey Z X C V B N M ESC Se ata haat ai aN Bota EE DRE it be Se A If the number of words that this ASCII Data Object should show is X then its equipment address should be 9075 X 1 6 13 ASCII Data iis ls Data displays the current value of the PLC register data The data 1s decoded by standard ASCII characters table ASCII yard that the low byte exists shows that on the left the display that the high byte exists 1s on the right Procedure to place an ASCII Data Part 1 Click ASCII Data icon Create ASCII Data Object General Fort Read address Device type Device address lo 2 Fill in General Tab Items Description A reference name that you assign to the ASCII Input not displayed Read Address Word or words in the PLC that is displayed and modiafied by the ASCII input up to 16 w
53. AL nnn Trend Display Periodically retrieve a group of PLC register data and TD nnn e decken XY Plot Periodically retrieve a group of PLC register data and X Y nnn System Set up system message SM nnn A e S HALE Ttg Recipe Downloads a block of registers to the controller or uploads RP nnn Transfer a block of registers to the HMI Event Log Set up the warning incident in Event log EL nnn E Event Display EasyBuilder 500 User s Manual Displays prioritized and formatted alarm messages as ED nnn triggered by bit status 1n a defined location 5 Object Window Treebar Object Window Tree bar lists the all objects windows The windows are numbered from 4 6 10 to1999 Each window is displayed by window No and window name The window without a Windows 4 Fast Selection H 6 Common Window 10 Initial Screen TS_OfLBO LED Battom La T9 D TS 1 LBDDDO4 LEODODA Ts s LBnDDOS LBEODODS T5 3 LB00012 LBDDD12 T5 4 LBOOD16 LBO0016 T5_5 LE00020 LBODOZD TS B LBDDD 4 LBODOZ4 TS 7 LBODD28 LBODOZS T5_8 LB00032 LBODOSZ TS_SfLBOOO36 LBEODOS T5 10 LBODD40 LEDODAO T5 1i LBODO44 LBODOA 4 window name is an empty window Right click the highlighted window and select Create to create a new window Double click to open an existing window The window with in front of the window No means it is open Right click the highlighted window and select Delete or Close to delete or close an op
54. Bold C Italic 4 UE Content Use label Duplicate this label to other states Tracking Label Library Use Label Library Apply Apply We place it on the window W EasyBuilder EBPrjlepj Window 10 Initial Screen SEE EB File Edit View Option Draw Parts Library Tools Window Help zm x D cy LP e v N a AEE a be B pum 4 B 100 96 v Language 0 v 0 1 23 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 State 0 v 4 Fast Selection a 6 Common Window a 10 Initial Screen LtL3 Ee ER BE a a wm us em ReoO0Z4 BIBBLBL He NC RP_ Up load E 0 d s amp ul Y For Help press F1 MODBUS RTU The recipe transfer object is done However the object just points out to transfer 5 numbers starting from the address of 4x200 to recipe memory but doesn t indicate the specific locations That s why we need LW9000 We set LW9000 as 300 Press transfer button and then we transfer the 5 continuous words followed by the address of 4x200 to 5 continuous locations after the recipe memory RW300 If we would like to 5 continuous data starting from 4x200 to RW100 we just need to set LW9000 as 100 To complete the example we create a ASCII input extend object to modify the updated data Set Device type as 4x device address as 200 No of words as 5 In trigger address set device type as LB and device address as 9000 ASCII Input Extend Objects Attributes Gener
55. C eee ma 1L 1L L EJESESESESERL TEE ES Doo eo eee R 0 G 0 6 0 Content Box Type in the characters to be displayed on the button in the Content Box The ENTER key can be used to move to the next line if desired Position Once the Part is placed on the screen the Label can be moved anywhere within the boundary of the object Just click on the label and drag the mouse to move it to the desired position Toggle through the state designator to display the predefined label in each state Click on Click on Drag to the obi ect the label in ove Use label Determine whether to show the content of labels or not Tracking When there 1s state of the label can use the label as moves a certain state of the decision to count at over o clock whether other labels follow this label to move together Choose follow this all labels of component will show in the same position 5 8 Task Button The EasyView 500 provides a method to pop up maximize or icon 1ze minimize child windows and change window displays There are 2 Task buttons a control Fast Selection Window another control Window bar Whether set up the use of Task Button or not in General of the system parameters attribute such as the color the position etc If Task button is enabled pressing the right hand task button will pop up a fast selection window The fast selection window can have several function keys placed on it by the user to change to
56. Change common window Window no 10 If the function key is set as Change Common Window when the touch area is pressed the current common window display is replaced by the new common window designated 6 7 4 Window Bar fltmdow bar O Minimize window A function key defined with Window Bar attribute is used to move the position of a window on the screen A Popup window can make use of this function The window is moved by touching the window bar area then touching a second position the window is moved to that place Alarm Status 6 7 5 Minimize Window CO Window bar 9 Minimize window When the function key is pressed the window is minimized to an icon in the task bar A touch on the window s icon returns to the original window The window 1 minimized to an icon in the task bar Note The Minimize Window function works only if when Task button on System Parameters General 1s open 6 7 6 Popup Window Popup window Close window CO JOG FS window Window Mo 10 If the function key is set as Popup Window when the touch area is pressed the window designated by Window No is displayed on top of the base window The existing window s are not closed Window 10 EN M indow 10 SAY in cow 100 6 7 7 Close Window Popup window Close window CO JOG FS window This is the method for operators to close Popup Windows but not for direct o
57. DIDemo cmp Uncompress source name CAEB5ODIDemo cmp Desti name CAEBb5 DIDemo epj T If the library already exists the dialog will appear Select Yes to all to replace the existing file EasyHuilder CAEBSOOW 7 engi ibraryMbuttonl slbl This file already exists Replace existing file Yes to all No to all Chapter 6 Object Object 1s designed for meet the specific demand generally speaking one object realizes a function but some object must finish the specific function with the assistance correlated with Object or PLC The following form shows Numeric Input Extend Function Key The keyboard is created by the function key ASCII Input Extend The keyboard is created by the function key Indirect Window Window that has already been created Alarm Scan Alarm Display Alarm Bar Alarm information show by the alarm display or alarm bar Alarm Display Show the information from Alarm Scan Trend Display Plot Data Transfer When the project has a lot of Trend Display Plot can cooperate with Data Transfer component raise and pursue the renewal speed of surface Event Log Event Display Shown the information of log in by BL LEN EN Event Display Event Log The information shown is logged in by BRUNNEN ce PLC Control PLC PLC procedure controls the operation of Most object support bit or word address type only Numeric Input Extend can operate double word because some PLC has Double
58. EasyBuilder 500 User s Manual Chapter 1 EasyBuilder500 Installation 1 1 EasyBuilder500 Startup Software Visit Weintek Labs Inc s website at http www weintek com to obtain all available software editions including Simplified Chinese Traditional Chinese and English version and latest upgraded files Hardware Requirements Recommend CPU INTEL Pentium II or above Memory 64MB or above Hard Disk 2 5GB or above At least spare disc space 10MB CD ROM 4X or above Display 256 color SVGA with 800 x 600 resolutions Keyboard and Mouse One for each RS 232 COM At least one available port for using in Online Simulator Project Download Project Upload Printer Operating System Windows 95 Windows 98 Windows NT Windows 2000 Windows Me Windows XP Installation Double click Setup and display as follows i EB500 V2 7 0 i EB500 V2 7 0 Welcome to the EB500 V2 7 0 Setup Wizard ey on The installer will quide you through the steps required to install EB500 V2 7 0 on your computer Select Installation Folder The installer will install EB500 V2 7 0 to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder WARNING This computer program is protected by copyright law and international treaties Install EB500 V2 7 0 for yourself or for anyone who uses this computer Unauthorized duplication or distribution of this progr
59. I Bottom Layer W O B1 3 11 WINDOW O11 TH OfBottom Layer sB OfLBO WO O bBU 12 WINDOW O12 FE O Bottom Layers FE 1 x AAA ad pd pd pd oe K Slightly x thin pen EA WL OL 2 sP 1 13 WINDOW 013 14 15 16 17 18 19 20 w we FK 0 function key is Clear board function FK 1 is the Brush function FK 2 is the Clip function FK 3s the Pen function FK 4 FK 5 and FK 6 represent 3 kinds of thickness of the pen FK 7 FK FK 12 represent 6 different color WL_O is Multi state switch with 6 states and correspond to FK 7 FK 12 six colors SP 1 is white shape SP O is self designed shape the setting as below Shape Object s Attributes Shape Profile shape hape library Apo Save Compile Off line Simulation On line Simulation or Download The result displays as below EasyView The system keeps LB9020 LB9022 and is used for controlling and combining identification Pen Brush Chip choose or not LLB9030 LB9032 can set the thickness of the pen LW9006 can set the operation mode LW9007 can set the thickness of the pen LW9008 can choose any pen s color from 256 colors Please refer to Ch12 for detail Ch10 Security Levels Security level which raises the safety of a project 1s as the admission for users to access to projects or windows When setting the attributes of the window we can see the selection of security level
60. LC Control Ohject s Attributes Head address BIN v Aux Attribute Type of control Change window v kiacro name Read Address Designates the address of the PLC control register Attribute Assign the operation activated by this function Type of control See Types of Controls below 4 Click on the OK button to create the object and exit the dialog 5 Click on the Close button to exit the PLC Control summary Types of Controls Change Window This operation uses two addresses The Read address holds the active window number If the value stored in the Read address changes to a valid window number that window number then replaces the currently displayed window The new window number is moved into the Read Address 1 register Read address Controls screen changes by number Read address 1 Destination screen number is written PLC Control Objects AHributes Description Head address Device type v Device address ol wt Attribute Type of control Change window Macro name As the example above the current window is 10 If LWO is assigned to 20 the current window will change to window 20 and value 20 then be returned LW1 Change Window precautions Whenever function key of one Change Window is pushed will close the present window and will show the goal window But PLC its function of controlling the component Change Window is similar to switching over the basic window the functio
61. Lib Select Lib New Lib me New Lib soll Unattach Lib Delete Shape Delete Shape wes ox cer 3 The display returns to the previous dialog Create Shape Object 5 6 JG 9 9 4 Click OK to place the shape EasyBuilder 500 User s Manual EasyBuilder 500 User s Manual Lasp lusides EHPp T gt Wide TU Initial Screen ah EE Fee Ed Vemm Don Deme Pub Library Fook Wi Heb OM D oa B5 r HT x wk EB Aud zara WON c Langesged c j l LA Is T Te ue e J rj ra Cf 34 5 8 8 39 I0 i13 14 15 15 17 18 13 20 21 e 3 24 AAT AA 30 30 alc v Fact hectic 1 Ex 2l l W 5P Olboteom Lar Q rl E h hs o o A ihe Ex J EIE Si Haie EIEEE He oserEmEEBiIiSs2 vi S tk iE ugBHzEHUHUuEARZZBUE 4 Bitmap Add a static bitmap on the screen by clicking Bitmap function The procedure 1s the same as creating a shape 5 Scale 7 Scale is useful with bar graph meter or trend display a NN 4 The types of scale are horizontal vertical or curved a de 1 Click Scale icon TERNURA LRL E ER LL 2 Left click to adjust the size of the object 3 Double click the selected object Scale Object amp Attributes Frame Select the color and line style to be used for the Scale Scale Select the Style to be displayed horizontal vertical or curved Up Down Full and Division Select the number of Divisions on
62. M General Trend Page type I TR pars Mn of page jd Hold style Hold trend display o Attribute Start fram left Sampling time L seconds Plot point Head address Device type LY Device address BIN Ho af channel n Scrall control Device type Device address Hold contral i Device type Device address Page type Select Multiple pages Multiple pages allows a trend display to be extended Data 1s plotted as before but it is not lost Data is stored in the memory for backup The maximum 1s 30 history pages for looking up Hold style Determines how the trend reacts when the hold bit is activated Hold trend display simply prevents further updates until the Hold bit is turned off Hold trend display amp clear stops the trend update and clears out all pages of the trend When the Hold style turns to OFF the trend display resumes Attribute Start from left selects to have the trend pens start from the left and traverse the display before scrolling begins Start from the right begins the pens scrolling from right to left from the first sample onwards In other words the pen moves the paper and way that the paper start writing Their show that the directions all roll and show from the left right Sampling time Time between point plots the unit is second Plot point The number of sample points displayed across the length of the Trend Display part Note The pl
63. Mode to choose Chosen PLC must RS 485 interface and Communication protocol must include PLC station No 2 Choose Extended Address Mode as follows in the systematic parameter system Parameter Setting PLC General Indicator Security Editor Hardware Aux Bezmimneg window nmo 10 Ww Compiler level Level 1 we Part layout Address mode 3 Fill in the form of Extended Address Mode as follows in Device Address of object Create Hit Lamp Object General shape Eead address Device type Device address 5803 Aux Attribute Function Blinking on state O Bekim 0 Create Set Word Object General shape Write address Device type 3x i Device address 4817 BIN v Midd value GE o Welt Pursue to show it for Extended Address Mode as above Bit address 3403 Word address 44412 Before is station NO later in order to appointed station NO Address Extended Address Mode in order to control yard with before is station NO later it was Standard Address Mode 7 6 The Hardware Tab system Parameter Setting PLC General Indicator Security Editor Hardware Aux LCD TFT PCD value EMME v Display mode Landscape Recipe Eventlog database Mo v DataBase start address system parameter Yes v TFT PCD Value This setti
64. Please refer to Ch 7 for detail Download Download a project compiled by EasyBuilder to the MT500 Please refer to Ch 2 for detail Upload Upload the project file from MT500 to an object file eob The upload file can t be opened by EB500 but can be transferred to another HMI On the other words the upload file can be transferred among the HMI with the same program Please refer to Ch 3 for detail Jump to RDS Remote Debug amp Simulation Mode Jump to RDS is used for On line simulations or debug Uploads and Downloads are done in this EasyBuilder 500 User s Manual mode You also can search system s ROM version or some system information Jump to Application Mode This 1s the normal operating mode of a unit Clicking Jump to Application runs the project in memory If there is no project or the project is broken in the unit the unit jumps to RDS Mode after booting You can download a complete project to HMI and then return to operation mode Jump To Touch Adjust Touch screen calibration Mode Jump to Touch Adjust is used to calibrate the touch screen Changing motherboards or displays have to use this mode to calibrate the touch screens MT 500 series shows the instruction to lead you to complete the calibration The three buttons of EasyManager describe above can be forced into switch to the corresponding mode far end On line operation mode and Touch screen calibration mode Touch Test Mode Test touch panel
65. RW 34 GGGGOGGG U 6666 The 7th group EW35 RW39 HHHHHHHH FERE The amp th group RWwW40 RW44 IMIT 8858 The 9th group EW45 RWAS JIJI 9999 Through the project design we plan to effectively exchange the data between PLC register 4x100 and each set of recipe data above In a project RWIO and RWIA display the receipt data of set number 0 Press download button to download the recipe data to 4x100 press upload button to upload the data of 4x100 to recipe memory The upward button executes the upward lookup of the recipe data and the downward button executes the downward lookup of the recipe data The current recipe data iz 4 Recipe nome Data LW9666 reduce ARAAAA F 4 pun A Lue to LH to reduce RHIG LW9666 add Up Load SuPerpose LH to add ie Ea After roughly understanding the purpose of the project we explicate the procedure of the project below At first create a new project and choose PLC type as MODBUS RTU in Edition System parameters Create a ASCII Input Extend object to display and amend the recipe name ASCII Input Extend Objects Attributes General Shape Read address Device type Device address n Vo of voris Trigger address Device type Device address 9000 nux Attribute kin Create a Numeric Input Extend to display and amend the recipe data Numeric Input Extend Objects Attributes General Numeric Shape R
66. SIEMENS 57 300 HMI Adapter SIEMENS 7 300 PC Adapter ml ATIC TISOS TAIAN TPUZ FDS 1 00 TELEMECANIQUE UniTelWaw Toshiba T serial Toshiba F 11 PDS v1 20 VIGOR YOKOGAMA Senes PDS V1 o Ds MITSUBISHI Melsec Q wal We support most of the PLC models For special request customers can contact with us to develop the new drivers HMI model Select the suitable model number from the dropdown MTS10T MTSOBT 640 x 480 v M CUR eee x 4800 MTS06s 220 x 240 MTS06L 220 x 240 MT OGT 220 x 240 TA06T Serial Port I F Select the PLC port s type of hardware communications RS 232 and RS 485 are available Baud rate Parity Data bits and Stop bits Set the communication parameters to match the PLC ports settings HMI station No This is used when PLCs require the HMI to have a node or station identifier For example for AB DH485 or Unitelway driver many HMIs maybe connect with a PLC and each HMI is given by a station No Leave it at O 1f just one HM1 is used PLC station No Used when PLCs have a node or station identifier Set as needed or leave at O 1f not used Multiple HMI Allows more than one HMI to be connected to one PLC Enable as a Master or a Slave depending on connection or Disable as needed Disable Disables the chaining of multiple HMIs to one PLC Slave Select this if this HMI connects to another HMI in the chain Master Select this when the HMI is the unit connected directly to t
67. Shape Tab Select Shape or Bitmap to enhance the effect of the display Create Numeric Input Extend Object General Numeric Shape Fant Shape Shape library Use shape Lo DJ 2 D 4 LJ 5 Fill in Numeric Tab items Set up the Font Color and Align of the display Create Numeric Input Extend Object General Numeric Shape Font Attribute Color a Fort 24 Align Right Adiust Content 6 Click OK to place the Numeric Data part on the window The format of the numeric display Decimal For Raw data Display the reading value is displayed in its original value as a decimal number in the range two attributes appear after selecting the decimal system Raw data display Display the raw data and arrange the data according to the No below Dec If the No below Dec is 2 the number 14561 displays as145 61 Do conversion The reading value is converted to engineering units before display Scaling is performed as follows Reading value Input min Engineering max Engineering min Display value Engineering min Input High Input min The changing value will show the data according to the establishment of No above Dec and No below Dec For example if the number as 123 456 but No below Dec 2 No above Dec 23 number value shows that as 123 45 the last datum has been removed after changing Example If t
68. Suitch over level EIE Press function key to switch window 11 If we set 0 for change level the current level becomes 0 and we can t switch the current window to window 11 Window 16 H s 2929 mmo current security level Pugssuord Input Suitch over level grs M MM as It raises the system safety to apply the reasonable password s ee TESTOR nd ee ee ore Ms ecurity level to the projects by different permissions for different operators
69. The attributes of the object as follows EasyBuilder 500 User s Manual Toggle Switch 61 y LT E E DTE CES General Shape Label Profile Description Read address Device type LB Device address Write address Device type LB Device address Attribute Switch style Toggle Multi Copy 9 Pitch Interval RGT X distance 10 Y Distance 1 Quantity X 3 Quantity Y 3 Adjust distance 3 Cancel aaluiider Eri IET ETE 10 iniba Serer EB Fl Ede Wess Geter Dra Fus Evan Tec Midi Hep Doll itan STE CA Ft SIE BE um ASU lib Languag mee E 4 om uud RH RE is UVisaa4b 8 B8 3 NW TJ 32 33 4 175 96 17 38 9H 20 21 72 23 74 75 zb 27 28 79 Ds Sec 1 F io EE k Yat abet E armes ane I Luo wai T5 Gib Ehre Pion LI t LESSEE 1609 i T Sere 15 uuo iDODODV i an BOOCI LEX i IDE Tu I por MEE e LE LE T rule iB a 11 2H 14 mj n a 9 HE Hj 2 14 oa Check the attributes of each object The addresses of them from left to right are Y1 Y4 Y7 and X and Y direction are each 3 objects EasyBuilder 500 User s Manual If the Multi Copy dialog shows as below Multi Copy 9 Pitch Interval AGT O BTM distance 10 is Y Distance 10 Quantity X 3 Quantity Y 3 Adjust distance 3 eme Click OK and then the result shows as the following diagram Laslo ir IT LEE LT n EU Id ITE Il EB File Ede Wess Omhon Dres Pati
70. The first register records the state of the object and the second one records the position X axis w reverse scaling Movethedirection contrary to X axis w scaling Y axis w reverse scaling Move the direction contrary to Y axis w scaling 6 9 Animation a The Animation Part is used to place an object on the screen at a specified location determined by a predefined path and data in the PLC The state and the absolute location of the shape on the screen are controlled by current reading value of two continuous PLC registers Typically the first register controls the state of the object and the second controls the position along the predefined path When the PLC position register changes value the shape or bitmap jumps to the next position along the path IE Q O D O Q o Preserving the route Q The figure will be moved in corresponding preserving the route Procedure to place an animation 1 Click Animation icon L1 2 Click on screen to define the path and stopping points points of track for the object to travel Right click to end the setting Animation Objects Attributes General Shape Label Profile Description Read address Device type Liw Device address i BIN v Ma of words 5 Ma of states 1 3 Double click the animation object to edit Attributes 4 Fill in General Tab Description A reference name that you assign to the Animation not d
71. Time Formar Rerum to normal ime Short time format HEND No Date Trig Time time normal time Event Note Be sure to allow sufficient character length to accommodate all information If the Format information and message text exceeds the Character length the message is truncated 4 Click OK to position the par Date Hour is obtained from System parameters General RTC resource If RTC source is set up for Inside RTC because inside RTC lies and must install Recipe Memory Card in Recipe Memory If Choose PLC then user to use Data Transfer object periodically retrieve the RTC data from PLC and write to the following address Now come to do an example about the fact that the incident shows 1 Project on it establish at first each it is new in editor system parameter in choose by correct PLC type and parameter 2 In incident log in in add 2 piece incident show picture Event Log Ohject Address Trigger Condition Content ID LBi1 n None LB10 ON Please cl p li L30 gt 0 The temperature is i dd The first incident among them the exporting value is 20 the second incident the exporting value is 21 3 Adding an indirect window in window 10 of project of establishing newly its reads address is LWS 4 Add an incident to show the component in window 10 u 1 Create Event Display Object Description Read address
72. Toggle Switch Object which controls LB10 LBO Breaks down Please check 9 Creat window 21 the following picture shows there are a text object and one Set word object Write address Device type Device address wt Attribute Dewhe i Boemiwt i xe jJ 9m ss BH 10 save compile on off line imitate or can t download this procedure operation result is like the Fig EasyView Reduce the temperature ee ee qn a EN ET 7 See De ee ee a ee Le i m ate oe tege att ee et Led Ee m ee ee EE ESS he ee ade waka IRR ERAT PAR Raise the epg temperature id When touch off LBIO or LW30 to the corresponding condition will present corresponding Event information In China s log in the outputs of 2 incidents are worth 20 21 1s the window serial number of event window that will spring when the incident 1s touched off 6 26 PLC Control FLI H The PLC control provides a way for the PLC to control HMI system functions Procedure to create a PLC control function 1 Click PLC control icon to pop up the PLC control summary screen PLC Control Object Change window 1 LBI00 Back lic Delete 2 Click on the Add button to create a new PLC control function Click on the Setting button to edit an existing PLC control function If you Click on the Delete button and the current highlighted function is deleted 3 Hill in PLC control dialog P
73. UEULO euge E C c B Bus zs zx El amo LLLA ELTETE CITEER T 26 96 Q4 174 5 7 Creating Labels A label means the text characters shown on the face of the Switch Lamp or other objects Parts Adding a label to a Part Click on Label tab 2 Select Attributes for the part Create Hit Lamp Object CO General Shane Label Attribute Color iR T Bold Italic Use label Use Label Library Tracking Label Library Duplicate this label to other states 3 Select the state to label 4 Type the state s label in the Content box 5 Click OK State States are displayed only for those parts with multiple states The text displayed for each state can be set independently Simply select a state in order to set its text font color and alignment Font A variety size of font 1s available 8 16 24 32 48 64 72 and 96 Alignment Justification When the text input for a Label becomes more than two lines the alignment can be defined as left right or center justification Color A maximum of 32 from 256 colors are available for selection the basic palette includes the most commonly used colors The customized palette allows the user to customize his preference color palette Select color icon to customize the palette Color Table E EN EN EE E ES ESECIEJEJESEJEIEJES ES eee DOO OOOO CE A wmf EC wef oo EE oof we A ERI EZ ERI fw Powe E79 CE ee ee
74. View Tool Help Welcome to EasyBuilder 500 Yeu Ctrl M u Please select your model Open Ckrl O f Model UU tae UR e FTU 1 EBFril z templateS20p Display mode Landscape v 3a l Language Single Byte v 4 ASCIIFant EasyBuilder 500 User s Manual 3 5 1 Screen Editor Overview The following shows the screen editor window The function of each screen area are explained below c Tool Bar d Stime Selector a Title Bar b Menu Bar x Wk Se pwd o wwe 10 Language 0 uli 2 3 4 5 E 7 E 9 WW t 12 12 M 15 16 17 8 19 20 21 22 n 74A 25 25 27 20 DU 339 39 Simen Mame e 4 ae Selection r e erry T end ien emat c Alignment mE Y us T ER UAE L1 I a E f Size Adjust C 13 i E ia is Us zo 2 P i L e g Position Adjust A ib i i an a 2 O La i i irou T 9 h Grou el D ir n E i Layer Control 21 s l l I m aux i a 1x7 L j Text size 9 zm and position ial 29 i e m Window Treebar roo k Rotate Tools a mi n Drawing Tools I Parts Tools 3 SSeS ES Ee ee M zi o Cursor Position Ai i 4j 1 7 For Helo press FI HOSE Pans cam Y WM a Title Bar Displays the project s file name active window number and title b Menu Bar Displays the menu used to select EasyBuilder commands Ther
75. WindowlS Wsin Popup Windewt E 350000 Fast Window 519771 00000 Common Window 39273080406 Timer 1 second 0 1 second Message Cueae Object Queue Object Queue PLC Block Queue 1 PLC Block Queue A base window occupies at most 400Kb which means if you place too many objects on the base window to exceed 400Kb error occurs A popup window occupies at most 350Kb fast selection window occupies 100Kb and common window occupies 30Kb Please refer to Help in Ch 8 3 The basic principle of window design is to select an object and set up the attributes Place on the display and then save the project Please refer to Ch 5 for basic design of windows Chapter 5 EB500 Getting Started 5 1 Create an Object A window includes a lot of switch lamp numeric input and picture etc Add an object to the window is very easy there are 3 steps procedure to create object Add object 3 steps 1 Click Toolbox object icon or from menu Object select one object 2 The object attribute dialog will appear Set the object s attribute Example PLC read write address Shape or Bitmap and label Imm Library Toole Wain Bit Lamp Word Lamp set Bit set Word Toggle Switch Multitate Switch Function Kew Numeric Input Extend Numeric Data ASCII Input Extend ASCTI Data Moving shape e L3 zd r v Create Hit Lamp Object General Shape Label Read address Device type Device address Aynnnnation I
76. a Numeric Input object Save Compile and Off line simulation Window 16 current security level Possvord Input Window 1 current security level Password Input mia a ________tT _______ i a E A O D E EEEE AiD xcci oe b ES ibd dla eu eee UR C Press the switch m button under security level 1 Sundowi is peueeesstully changed to window 11 EasyView Window 17 reri er C However how to switch the higher level security to lower lever security LW9043 allows the project to force the HMI to a lower security level Add a Numeric Data on window 10 as below Create Numeric Input Extend Object General Numeric Shape Desorption Read address Device type LIW Device address 9043 BIN No of words v Ah Ux Trigger address Device type Device address 9000 Save Compile and Off line Simulation Ea syVi ew Window 16 current security level Passvord Input Suitch over level A AAS eh Am AS UME RA aca TEN TS amp Input into Change level but current level doesn t become 1 A lower level can t be force to higher level Ea syVi ew Window 160 current security level Passvord Input Suitch over level esr es Senate dese Urdu g eder Va ond rS t riv chc Rd Now we input password 1111 to change the current level to Ea syView Window 160 1 M s95955 MINIS o current security level Pussuord Input
77. ability ID Bit Lamp Displays On or OFF shape to reflect current bit status in the PLC Word Lamp Displays different shapes to reflect current register data in WL nnn the PLC Set Bit Changes the state of PLC bit address data Writes specified data to a PLC word address Toggle Switch Combination of bit lamp and set bit parts EasyBuilder 500 User s Manual Multi State Combination of word lamp and set word parts Switch LN Function Key Creates a touch area to input data change window pop up FK nnn zi or minimize a window or leave the memo Moving Moves a changeable object on the screen MV nnn Shape Animation Moves a changeable object along predefined track on the AN nnn screen or displays the different states of the object Numeric Displays PLC registers data in numeric form and allows NE nnn Input keypad input for changes Numeric Data Displays the PLC register data only in numeric form ND nnn ASCII Input Displays the PLC register data in ASCII and accept keypad AE nnn input ASCII Data Displays only the PLC register data as ASCII characters AD nnn Bar Graph Displays the PLC register data as a bar graph BG nnn Meter Display Displays the PLC register data as an analog meter MD nnn iB ju T Indirect Calls a specific pop up window by a PLC word address WP nnn Me emere mei vnm Direct Controls a preset pop up window by a PLC bit address WC nnn Window BUE amp Alarm Displays alarm messages
78. accuracy In this mode when you touch the screen there is a corresponding display on the point you touch which for you to test the accuracy Note This mode change isn t on the EasyManager menu But it is done by changing DIP Switch Please refer to DIP Switch chapter for detail Exit This button closes the EasyManager application 3 2 Download Before a project can be downloaded it must be compiled There are two methods to process one is through the download button of EasyBuilder another one is from EB500 select Tools Download in the menu bar or press Ie icon to download TacyManaper a a E 1 Downloading through EasyManager CUM 1 115200 bps Project Downtoadupload Select Start All Programs EasyBuilder Easy Manager Complete Downlaadfplaad Oline Simulator chapter Download Click on DownLoad button Jump To Application Jump To Touch Adjust Set up all necessary parameters Please refer to EasyManager part in this Diea Online Simulator Exi EasyBuilder 500 User s Manual File name Files of type EasyView Object File eab C Open as read only Choose the project file and then click Open Easy Download complete project C Documents and Settings poy E Downloading binary file Cancel Downloading begins with the Easy Download dialog popping up and is tracked by the progress bar After downloading click OK Click on Jump To Applica
79. al Shape Font Read address Device type Device address Trigger address Device type Device address S000 Attribute sin Create a Numeric Input Extend object to amend the data of LW9000 where device type is LW device address 1s 9000 in trigger address device type is LB and device address is 9000 Numeric Input Extend Objects Attributes General Numeric Shape Read address Device type Device address S000 No of ait AWK Trigger address Device type Device address S000 We place a ASCII input extend object to display the data of RW300 and check if the data 1s transferred The setting shows as the dialog below ASCII Input Extend Objects Attributes General Shape Read address Device type Device address p g Vo of vods Aux Trigger address Device type Device address S000 Mx Attribute Hist Then we place a keypad A complete project displays as follows M EasyBuilder EBPrjl ep Window 10 Initial Screen EB File Edit View Option Draw Parts Library Tools Window Help Dg X m amp 9 M ga AZ x 2a E B HT gt me 100 v Language 0 v lFoNT 16 Mi AX S B 7 amp Sp sy ot oh SR Wy X 4d dA ase a4 0 1 23 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 State 0 v 4 Fast Selection 0 Initial Sereen RA I LI9O000 AE E_8 AAAAAAAAAA HHHH 4x200 AE_
80. al Tab Items Description A reference name that you assign to the Numeric Data not displayed Read Address Word in the PLC that is displayed and modified by the Numeric Data Tab Data format is defined data as binary or BCD The number here is limited to 1 16 bits or 2 32 bits 3 Fill in Numeric Tab items See previous section on Numeric Input Extend Create Numeric Data Object General Numeric Font Display Decimal Hex C Binary CO Mask C Single float Double float Raw data display Do conversion Humeric No above Dec No below Dec Input law 0 Input high 9999 Display Control the display format of the data Value Set up the position of the decimal point 4 Go to Font Tab Fill in attributes of the displayed digits See Numeric Input Extend Create Numeric Data Object General Numeric Font Attribute a Te B Colcr a Font 16 Align Right Adiust Content 5 Click OK to place the Numeric Data part on the window 6 12 ASCII Input Extend HEC E o Input Extend displays current value of the PLC register data as decoded by the standard ASCII character table When the trigger bit 1s active ASCII Input 1s available through the alphanumeric keypad Entered data is put into consecutive PLC registers starting with the Read address The ASCII code saved in the low bit displays on the left had side and the code saved in the high bit displays on th
81. am or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Everyone 9 Just me Choose the destination EB500 to be installed and then click Next Click Next EasyBuilder 500 User s Manual if EB500 V2 7 0 Jis if EB500 V2 7 0 Confirm Installation i Installing EB500 V2 7 0 The installer is ready to install EB500 V2 7 0 on your computer EB500 V2 7 0 is being installed Click Next to start the installation Please wait Click Next to confirm installation Installation processing i EB500 V2 7 0 Installation Complete EB500 V2 7 0 has been sucessfully installed Click Close to exit Click Close to finish the installation Chose menu Start All Programs EasyBuilder to start the program Tour Windows xP A WordFad Files and Settings Tr SG Wizard wi MSN 55 Outlook Express E EasyasciFontMaker A EasyBuilder 500 EN EasyManager ImagecF PLCAddressView Remote Assistance i e Windows Media Player gt Windows Messenger fe ReleaseNote pdf ig Reserved Word bit pdf E Windows Movie Maker All Programs f B EasvBuilder Each meaning of selecting is as follows under the software menu EasyManager MT500 comprehensive management software EasyBuilder EB500 configuration software ImageCF Convert the eob and related bin file into
82. among them control the component increased to set up as follows Set Word Object s Attributes General Shape Label Profile Description Write address Device type Device address 10 Attribute Set style Inc value JOG delay Controlling the component reduced its write address is LW10 too attribute type for decreasing progressively decreasing value 5 go to limit 0 Add a Toggle Switch over the switch controls the switch of LBO delay reading the materials in order to control the trend display it 1s set up as follows Toggle Switch Object s Attributes General Shape Label Profile Description Head address Device type LB Device address 0 white address PUE Device type LB s Device address l Attribute Switch style Toggle Cancel Window 10 shows as follows finally L Dasyllulldor OPrj Window 10 initial Screen EB fle Cat ses Open Denm Parte Ubar Tooke Windies ha D oF B n atv we X E E EH was A AnA 100 Language D 01 2324 5857 B 3 10 12 13 14 35 16 17 18 139 20 21 22 23 24 25 26 27 28 79 30 31 Stc anim k 3 P adf Dalah Sm 7 amp c Laren ike x zx aii bial Sereer FD OWE Wa oerte Layer L1 SM OSA it Sa Lian a ow 20 we A WL Pl SM ALIE TU DII die E u y Hu r Iz Ls Lt uL Lun 2 a 3 mj E nl it save compile off line simul
83. anual E ER Ex ERI Ez Ez E EI EE EC EE EE ERE en wer EHI ERI EI EI EXENENERNRC1 ESENEJESES ES E ES ER ERI CO EI EE ESI E51 ESI EZ ES EHI ESI EHI EI EEII EI ESI ER EREN O O o a a a a ESL TEES ES Do OOOO eee H 240 G 240 B 240 R U G 0 B O 2 Text Click on the Text icon to display the Create Text Object dialog as below Create Text Object Text Attribute Color m Font E tion lek Content Text L Label Library Font 8 16 24 32 48 64 and 96 font sizes are available Align When the text input for a display more than2 lines the alignment can be left right or center justified Color Choose 32 colors out of 256 colors Basic colors include the common use colors and customized colors allow you to choose your favorites Content Type in the characters to be displayed When typing in the characters press the ENTER key to move to a new line 3 Shape The function is to place a static shape no the screen the procedure is as following 1 Select Shape from the Draw menu or click icon to pop up the dialog as below Create Shape Object Shane Muy G S G s S MEC BEIDE Shape library State 0 2a ae of f B Untitled 9 Untitled q0 United 11 Untied 12 Untitled 13 Untitled 14 Untitled 15 Untitled Background E Frome FL Select
84. ar indicator in proportion to its value as defined by the SPAN and ZERO setting Procedure to place a Meter 1 Click the Meter Tool Create Meter Display Object General Meter Display Description Head address Device ype Lw Device address v No of words 2 Fill in General Tab Items Description A reference name that you assign to the Meter not displayed Read Address PLC word that used to control the displayed value Create Meter Display Object General Meter Display Indicator Style 1 amp Up half Full up Full bottom C374 full Style 2 Up half Full up Full bottom C 3 4 full Color Am E Zer Span Value Data format Defines data from the controller as binary or BCD No of words Restricted to 1 3 Go to Meter Display make selections and fill in fields as desired 4 Click OK to position the Meter and resize it Color set indicator color Percentage of angle relative to 180 for Half circle and 360 for Full circle Register value Zero Span Zero 100 Indecator style Style 1 2 Up half Full up down and 3 4 full Up half Full up Full Down 3 4 full Notice The indicator will generally cooperate with the component use of the scale will strengthen the operation result of the indicator with the scale It please consult 3 5 6 chapter menu drawing scale some content not relevant 6 16 Indirect Window By The Indi
85. ation the following picture of operation result of it shows Push stop the trend display will be too static to move Pay attention to observing and looking through movements of the page at this moment Is it look through to carry out once movement of page trend display reference position of coordinate of on the left move 5 most 1s it look through Set Word object set for to control namely increase value or decreasing value number value this piece there 1s number value 5 take a sample by distance that order There are some of 21 samples in all on the screen the scale just divides the screen into 20 squares for 20 partitions each square 1s distances that 2 samples are clicked 6 21 Alarm Bar Ce The area where Alarm bar will locate in Alarm bar shows by way of horse race light that what touched off preserved alarm information this alarm information must be about nodal address of some the unit this location address is touched off until warning stated alarm information will roll and show from right left Alarm will have rolled until this location address has been switched over to the non warning state continuously all the time Log in in alarm information must be in object in advance This object only shows alarm information must be by object wanted to show in object log in of Alarm Scan In systematic parameter generally in Alarm bar partly it last Alarm bar speed roll u 1 System Parameter Setting
86. bjects defined to the underlay window such as control objects set bit function key etc Moreover if show the object in the common window can show on the present screen too all control objects defined to common windows are effective on the active window There are 1999 windows available in a project including base window common window and fast selection window but only one fast selection window Switch the assigned window as a fast selection window by the Jog FS window function key Please refer to Function Key chapter for further detail Each new project has an initial screen the window number is 10 or 1 please refer to System parameters Editor A project often uses several windows Valid range of the window numbers is from 10 to 1999 number under 10 is reserved for system such as window 4 for fast selection window window 6 for common window NOTE 1 Maximum 6 popup windows can be open at the same time If using print function maximum 5 windows are displayed If selecting compressed object function maximum 4 windows are displayed The reason is because each of the function occupies one window 2 One window can be opened once at the same time Therefore a window can t be opened by two direct indirect windows on a base window 3 Using Function Key parts with Close Window doesn t close direct or indirect window This is because the on or off of the direct window is only related to the On or Off status of th
87. brary are described as below for a Multi States object Create Set Word Object General Shape Label Write address Device type SEO wo O w Tag Attribute set style Add value JOCH Ww A new Tag item is found in general page of a object attribute dialog If this Tag item is checked users can select an existing tag in the tag library for a particular address Notification Not only addresses can be used clearly and directly through a tag library but also it is convenient and practical for modifying some partial addresses after completing a project When a purpose built address must be changed it is unnecessary to modify this address on all relative dialogs and users only correct this address in the tag library 5 14 Compressing Project After a project is set up successfully it can duplicate in other computers or store to other catalogues Will meet 2 questions at this time One is all kinds of problem of the file But present hard disk space is all bigger so this question 1s not big One is that this project may use a lot of Shape Library or Bitmap Library an impossible one users will go to find these picture libraries that it use to duplicate with this project file afterwards so EB200 offers and compresses the function It is smaller that it can make the project file compress and all picture library files Shape Library or Bitmap Library etc applied this project to are compressed into
88. ce D Superpose LW8 to reduce RHIG RHI 4 LW9666 add m RE E L to add We input the 10 sets of recipes into recipe memory card and then jump to the eighth set Change the recipe name as KKKKKKKK recipe data as 1234 and press the download button The current recipe data is a Data Recipe nune LW9666 reduce K K K K K K S 1 2 3 4 A ieee ee ie RHIG RHI 4 KKKKKKK 1234 rv I ric We find the data in 4x100 becomes below Serial number of Register address Recipe name d Recipe data l Falle mad Ai The Oth group RWO RW4 AAAAAAAA O 5 RW 10 RW 14 Hec UTI gt Address Data The third group RW 15 EW19 DDDDDDDD 3333 C Ax 100 4x103 KKKKKKKK Through the procedure of the project we grasp the basic 1dea on designing recipe data 4x104 1234 Ch9 Message Board Designate a window as a message board where an operator can input information in it Designate this window from System parameters General as follows Here we assign window 11 as the message board System Parameter Setting General Attribute Background color d larm bar Pixels per roll No of windows wv Password Startup window no E Back light saver Cursor color Buzzer Common window T Popup window hl Attribute Below base screen Extra no of event RIC source Internal RTC Print Printer Print sequence number Print
89. cmp for one with project file In this way can utilize and deserve cmp file comes to transmit the project file Only have to decompress it when use this project file all its storehouse files used will be decompressed to the acquiescence route too The course compressed and decompressing 1s as follows Select the menu Tools Compress Uncompress the dialog pop up Compressing Compress Uncompress Use the Browse feature to find the project to compress The Destination name is automatically assigned This name can be changed by the user Compressing Compressing Compressing C EB500 0emo cmp Compressing CAEBSO0 W2 Oeng Librar button1 sib CAEBSOOW Oeng Libra Compress source name C EBS00 Demo epj Desti name CAEB5O0DIiDemo cmp Compressing Uncompress Click Compressing button to begin the compression process The picture show the project compress to demo comp Decompiling procedure like Compressing Browse for the project to decompile The Destination name si automatically assigned but can be changed Click Decompile to begin the decompile process Compressing Extracting CAEBSOOW Oeng Librar button1 slb size 266431 bytes Extracting CAEB5BODYV2 7 engY ibranbutton slb size 32b817 bytes Extracting CAEBSOO W 2 0eng Librar Button Caption slb size 66515 bytes Compress source name CAEBbUDIDemn epj Desti name CAEBb5 U
90. ct a epj Browse Source window nn 11 Desti window nn 1 w cancer Click OK and then pop up a message box Select OK EasyBuilder 500 User s Manual Source projectf aT CAEB500W271 2 Do you want Ep overwrite window 10 ae 5 Cox Window 10 is covered by window 11 Window 10 shows the same content as window 11 Similar way is used in copying windows among different projects Browse the file epj that has the window you want to copy or import Fill in the Source Window No from the epj project Select a window number in the open project where the window is to be placed 6 Layer When many projects layer one on top of the other through pressing Ta ers enn or selecting the Edit menu Layer submenu to change the order of the objects Select object and An object may be brought to the front back front one layer at a time or back one layer at a time by choose a corresponding icon Lower floor the most 7 Nudge Choose an object and the object position moves can be adjusted by nudging Press the cursor keys on the keyboard to move an object or group one pixel at a time Object position moves can be called 8 Align Objects can be aligned by their left edge vertical center right edge top edge horizontal center or EasyBuilder 500 User s Manual bottom edge Object alignment can be called from the Edit menu Align submenu or by clicking on the appropr
91. d The value is the window number of the popup indirect window 4 Click OK the message appears in the Event Log message summary box Note In order to take full use of communication bandwidth it 1s recommended that a block of continuous PLC bit devices be used for the Event Log list For example Use Bits 100 to 199 to control the display of all event messages so that one read command retrieves Bits 100 to 199 all at once instead of one bit at a time 6 25 Event Display ED The Event Display part opens a window to display messages in prioritized order Various formatting features allow the display of event trigger acknowledge and return to normal times The use of the RTC or the retrieve of time from PLC 1s required for proper display of the time This object displays the event only Procedure to create an Event Display Part 1 Click Event Display icon 2 Fill in General Tab Items Create Event Display Object General Event Display Description Read address Device type LW Device address BIN No of words Write address x Device type LW Device address BIN No of words Description A reference name that you assign to the Event Display not displayed Read Address Used to control the scrolling up and down of the Event display window The value in the read address is the relative distance from the event in the topmost line of the display All active messages are sorted by
92. d Example of an Alarm Display A Shape SP 0 is used for the background rectangle The Shape SP 1 shows the sunken viewing area Some TEXT is placed on the Shape AL 0 to identify what is being displayed Two Set Word parts SW 6 SW 7 are used to increment and decrement the alarm register The actual Alarm Display part is placed on top of the shape and the alarm messages appear as below The alarm showing Loading and unloading ie too low on stor The alarm showing The dlippery driving wheel is started un Enter the material mistake The Lirection is changed unusually 6 20 Trend Display The Trend Display periodically retrieves a block of PLC data and displays the trend data over time As each sampling period elapses the new data is read from the PLC and inserted towards the right side of the trend graph It shows that has real time Yield Efficiency Shape Scale Trend Display The newest data show that on the left the orbit 1s moved right Hinutes An example of a typical trend display is shown above A Shape is used for the background and Scales are added to show relative information about the trend The trend display is then placed on the Shape Procedure to add a Single page Trend Display 1 Click Trend Display icon 2 Fill in General Tab Items Create Trend Display Object q General Trend Page type piiae fm wt a ta Sampling time seconds Plot point
93. d ON Set OFF at When the window containing this Set Bit Part is maximized the designated window PLC address 1s turned OFF maximized Set OFF at When the window containing this Set Bit Part is minimized the designated window minimized PLC address is turned OFF Set ON at window When the window containing this Set Bit Part is minimized the designated PLC address is turned ON Set ON at When the backlight is turned off the designated PLC address is turned ON Strat RN Set OFF at When the backlight is turned off the designated Device address is turned Set ON at enter When a function key with the ENT attribute is pressed in response to a SUCCESS Numeric Input or ASCII Input part and the attempt to write the data succeeds the designated PLC address is turned ON Set OFF at enter When a function key with the ENT attribute is pressed in response to a SUCCESS Numeric Input or ASCII Input part and the attempt to write the data fails the designated PLC address is turned OFF 6 4 Set Word Id 3 eal The Set Word Part defines a touch area that when activated you can write a predefined value constant to the designated PLC address Procedure to place a Set Word I Click Set Word icon Eal 2 Fillin General Tab content Create Set Word Object General Shape Label Description Write address Device type Law Device address 0 BIN v Attribute Set style Periodical JOG Inc value 0 U
94. d window can popup Window 14 As the picture shows HazyHtodder t_ _ FS_Wisdlow epi Aindow 10 mia Screen WE Fie Edit Yew Optom Drew Pet Larry Tock Widoe Help D oe ld Bo Btw A SAS aww SB Pee Aaa FS OK Cl re g ra ra E B oe UN 1 ES R 2 L Gl dl tl S d 1 2 34 5 amp fF 8 9 10 11 12 13 d4 15 16 17 18 19 2U 21 22 23 24 25 26 27 28 29 30 31 State O amp 4 Fed Sekt x ho boum Prumd w gt WD bial Seren 11 WOES 0101 ja i 12 WINDOW 012 Bas ic i ndow 1 13 WIND A 015 14 WINDOW 4 rg um namo TOTA CHH D lj BO he m E P s z J 0 p S d Gl MITSUBISHI FXdu FX2 6 Put a text object at Window 11 show text as Basic Window 11 and one function key of Return to Previous 7 Put the function key of one JOG FS Window at Window 12 can switch over the function key of 4 2 windows Change Common Window switch over to Window 6 and Window 13 respectively As the picture shows K Common Window 1 FK Ennmnon Window 8 Put a text object at window 13 show text as Common Window 13 9 Put a Window Bar at window 14 show the content in order to Popup Window 14 and 2 function keys of Minimize Window and Close Window 10 Finish setting up Save Compile Online Offline Simulator or Download can show the result in the picture EasyView Basic Window 10 i Popup Window 14 Common Window 6 iia F4 11 Base Hindou 11 Push Return afte
95. dfUpload nline Simulatar File name Files of type EasyView Object File eab y C Open as read only Jump To ADS Input the file name Click Open If the password is set on the project it pops up a password message box After the password is confirmed the pop up message box appears as below ga Easy Upload project C Documents and SettinpsYpoyiMesktopW 27 x Uploading object file EasyDownLoad X Mission complete Ok Click OK after downloading Find the file from the corresponding location and then download to other HMI or run On line simulation EasyBuilder 500 User s Manual 3 4 PLC AddressView we MSN 5 Outlook Express E EasyAsciFontMaker w EasyBuilder 500 IN FasyManager ImagecF a windows Messenger oie PLCAddressView pe Remote Assistance windows Media Player E Windows Movie Maker E R eleaseMote pdr ir Reserved word bit pdf an EasyBuilder pr p i nnt HIT SUG PA A PULA Type iO Havent beer Type Ackbwesing Femal Max Ma w Wipri HB Ms Lw et j Vg g MITSUBISHI Pinte FLC iD 1 BamM BnP E HAFLI DAFL Marke Harc Wodh E weedPLE TV Weed PLC Wwe PLE Crom PLE Dvz wiwdPir 5 WitedHMI BiiHbl BRHMII Weed Hbi Hi MITI Hs HB Bit is a base unit eight bits are one byte two bytes are a word and two words are the Dword d Decimal o Octal h Hexadecimal Bit HMI HMI bit
96. dge Left Make object Nudge Left Nudge Right Make object Nudge Right Align Left Make several object Align Lefts Align Vertical Make several object Align Vertical Align Right Make several object Align Right Align Top Make several object Align Top Align Horizontal Center Make several object Align Horizontal Center Align Bottom Make several object Align Bottom Make Same Width Make several object to the same Width EasyBuilder 500 User s Manual Make Same Height Make several objects to the same Height Make Same Size Make several objects to the same size Group Make the object form one group Ungroup Cancel one group of groups Flip Vertical Flip up or down Flip Horizontal Flip right or left Rotate Rotate counterclockwise 90 degrees 3 Draw Toolbar 7 Select In choosing the object state Attributes Change the attributes of the object Line Draw a line Rectangular Draw a rectangular Ellipse Circle Draw a ellipse circle e I DI ur Arc Draw an arc Text Add the text Bitmap Add the bitmap Scale Add the scale Polygon Draw a polygon Shape Add a Shape DEM C Alarm Scan Add alarm message System Message Change system information PLC Control Add PLC control elements Event Log Add event log object H S ul Data Transfer Periodically retrieve object s data from PLC 4 Part Toolbar 1 amp 2 Icon Title Cap
97. ding library Specifies the related Shape and Bitmap libraries for that group of objects If the related Shape and Bitmap libraries are not included with the project the group objects will be displayed as boundaries of shapes and or bitmaps To correct this go to the Shape and Bitmap libraries dialogs and open the required libraries Select Lib A Standard Dialog Box for selecting a file appears Select the name of the Group library to be opened New Lib A Dialog Box for entering a file name appears Enter the name of the group library to be created Place Select the group of objects and place it on the screen Group Library Library name h keypad Including library Shape SYS Button JL C Seatin Newb re Unattach Lib Remove the library from current project Delete Delete the selected group library Close Close the group library dialog 2 Call up the group of object from a Group library In the Library menu select Group Call up library or click Bl icon The dialog will appear Group Library m name keypad v Including library Shape SYS Button v EEN Select the group click Place The objects on the current window MeKeryEmidar EBTrj Wisdow IO Initial Teresa f Iff Wudow He 28x are A x 3h BE Yn A Aky 100 Language PRES E S m oO mw It la 4 4 5 Bh F B 9 i 11 VW 13 14 15 16 17 B 19 A 21 22 23
98. dow N will be closed then show basic window M and its subsidiary window The basic window must fill up the size of the screen Fast Selection Window It is activated when the Task Button associated with it is pressed The window displays on the screen unless it s hided from Task Button So it can put Task Button which switch over the window or other commonly used object It is designated as window number 4 When reassigning another window as Fast selection window the size of that window must be the same as the Fast selection window Common Window Common window shows on the screen all the time object showing needing all the time is put in this window and you can see the state or operation of object at any time Common window is window 6 The Common window can be changed via Function key but here should be only one active common window Message broad window Each project has only one message broad window which is set from System Parameter Setting General The size of window can be set If several windows use message broad window actually they use the same message broad Please refer to Ch 9 for further detail Underlay Window Up to three windows can be specified as underlay windows The common objects used by many Windows are usually placed on the underlay window such as background graph and title All windows can be assigned as underlay windows Window Setting Hame Initial Screen Window no 10 Start Pos X
99. dress type When value in word is less than entered value use lt to trigger When value in word is greater than entered value u se gt to trigger Event Log Object s Attributes Address type Sir Read address Device type LW Device address 30 BIN Aux Attribute Condition vi 0 Print L On trigger Return to normal Category 0 Text Content The temperature is higher than 0 degrees H Color M Font 24 Use label library Label Library Write value Print On trigger Prints out message when event is triggered Return to normal Prints out message when the event returns to normal state Category Event category reserved for future use Text Input the context color and font of the event information Note The inside data in the body of memory can include in Event information The format as follows Yonnd The starting delimiter nn An internal register LW number 00 99 d The ending delimiter For example The Content field is set as Current temperature value 25dF HIGH ALARM If LW25 120 then the message are printed out as Current temperature value 120F HIGH ALARM To print out current value of PLC register data first assign a Recipe transfer object or PLC Control General Control to move data from the PLC to internal LW memory Write Value A value to be written to the Write address of the Event Display when the event is acknowledge
100. e 1j S Meenngatiore wies sPepee Wind If this project create AlarmScan and EventLog object then ammenPage m clicking on Update Information e i window 0 will run all the time So long as AlarmScan and EventLog happen the system will be dealt with at once If use TrendDisplay or Data Transfer then window 1 will run all the time in order to obtain the information that TrendDisplay or Data Transfer need If use Message Board because the information of the message board needs keeping all the time the message board window will exist all the time If use Common Window then window 6 must exist all the time In the graphic Update infermation PLC Monitor fa Open every item there are 2 kinds of to show the color all Fiend PLC Block information DIDIT contents among them a yellow one is the touch sensitive screen presentation above window 34 it is Open window at present Iz Thit windy contain X ncm uem tosend the data to COM port a getting blue one data that E ddcess nn na 0 fends i E Number 6t Object inside punish BB Object tetormation hr Block Capture Display the communication data with PLC 3 Perse m 3 Addvess 00000 gzv onts 1 Hureber i Ohprees Object donation Alarm aiin PLC Black Actheity Bleck Capture 3 System resource Il utem Resource Select System resource to view all resources allocation of the inner Window 0 67664 570000 Hase Window
101. e a blank new project 1 After installing the EB500 select Start All Program Easybuilder Easybuilder 500 5 Gutlook Express Ex EasvBuilder 500 IN EasyManager ImagecF FM PLCAddressView pe Remote Assistance windows Media Player 2 Windows Messenger aa Windows Movie Maker ig ReleaseMote pdf ig Reserved Word bit pdf l fal EasyBuilder 2 If it s the first time running EasyBuilder or a last blank project was opened on last time log in the following popup dialog appears EasyBuilder Welcome to EasyBuilder 500 Please select your model NS Model MT510T MT5O08T 640 x 480 Display made Landscape Language Single Byte Select the model of the display and then click ok Otherwise the last open project is opened for editing Select menu bar File New to create a new project the following popup dialog appears Select the appropriate model you are programming Here we choose model MT510T 508T 640 480 as an example then click ok EasyBuilder wie Edit View Option Draw Pa Welcome to EasyBuilder 500 Mew Ctrl M Please select your model No Open Chrl 0 gt Clase Model ZUEL SERIA UP LUE ELI Save C Eri a 5 Display mode Landscape Save AS Language Single Byte EasyBuilder 500 User s Manual 3 We can easily create a new project in this way In the menu bar select menu File Save to save the project as a epj The display shows as below
102. e as follows Name Give each window a unique name in order to identify it Window No Valid window numbers are from 10 to 1999 1 to 10 is reserved for system Start Pos If this window is popup window the angular vertex will be located in this seat on its left Size Set appropriate width and height Set window width as full screen size 320x240 or 640x480 depending on model if it S a base window Style Tracking Monopoly Clipping and Coherence These parameter types have pointed out that one spring relation between the window and window in close proximity to it If there is monopolizing nature at a window then when it springs its father will be frozen at window and spring this at the window and show it all the time in its upper strata the most If there is cutting and getting rid of nature at a window be then limited by its father s window at the border of this window that 1s to say that shows that the part outside its father s border of the window will be cut down If there is following nature at a window then when the father in this window moves at window it will follow to move too Both the Clipping and Tracking must be selected on the same time Coherence means that there can be no windows between the calling window and this window One cannot be brought to the foreground without the other both will be brought forward For example window A and window B are on the base window Generally speaking window A is
103. e bit lamp address while the on or off of the indirect window 1s only related to the data of the word lamp The function key couldn t change the data of the addresses to close these windows 4 Window 0 to window 9 are used for system such as window 4 for fast selection window window 6 for common window Only from window 10 to window 1999 are available for any usage 5 Popup window is attached on the active base window When base window is closed the popup window is automatically closed If you switch to the base window you will find the popup window still attaching to the base window is active Unless there is order closed 6 Base screen must be full size 7 Fastselection window doesn t support popup window which means that it s not allowed to use popup window on the fast selection window 8 Being touched off and opened popup windows will be added on base window all windows of the same situation can be regarded as the set membership So object in common window touches off the open window and exists all the time unless object in common window touches off and closes 1t 4 2 Window properties Window 5etting Name Initial Screen Window na 10 Start Pos X 0 bs 0 Size Width 640 Height 480 Style Tracking Monopoly Clipping Coherence security level Lowest Underlay window 1 None Frame Width 4 Background Color ms Pattern Filled Pattern color doe Window Setting prov
104. e is a corresponding dropdown under each function bar Each choice in the dropdown execute an operation c Tool Bar Displays the icons corresponding to File Edit Library Tools Simulation and up download menu items d State Selector Selecting different state toggles all the parts on the window to the specified state e Alignment EasyBuilder 500 User s Manual Makes all the selected parts line up to the top bottom left or right f Size Adjust Makes the dimension width or height of all the selected parts the same size g Position Adjust Adjusts the position of selected parts h Group Makes a collection or combination of selected parts and drawing elements as one object Save the group to the library for next time use i Layer Control Adjusts the Layer of selected part V one layer up one layer down to top layer and to bottom layer j Text size amp position Changes the font size and alignment of the selected text k Rotate and Flip Flips the shape horizontally or vertically and rotates the shape in 90 degree increments l Parts Tools Each icon represents each Part type Clicking on one of these icons causes that iconjis dialog to appear That Part s attributes can then be set and the Part can be placed on the screen m Window Treebar Provides quick access to Window properties or objects n Drawing Tools Each Icon represents each drawing tool These tools include line
105. e right hand side Value read is solved and translated hA AAAAAAA and shown by ASCII yard fo JE JF oo tie ESC ENT Activate touch area and enter the introduction state EB a EI EIE EE Input from the keyboard jm SEE Procedure to place an ASCII Input 1 Click ASCII Input Extend icon Create ASCII Input Extend Object E General Shape Font Description Read address Device type Lyf Device address 0 Mo af words 1 Trigger address Device type LB ww Device address O Attribute Adjust Right ox emen 2 Fill in General Tab Items Description A reference name that you assign to the ASCII Input not displayed Read Address Word or words in the PLC that is displayed and modified by the ASCII Input up to 16 words may be addressed in this manner each word contains 2 ASCII characters Trigger Address Bit in the Controller that controls the ability to enter data into the Read Address If bit is OFF data entry is disabled Attribute Select to Left or Right justify the ASCII characters as they are displayed 3 Go to Shape Tab Select Shape or Bitmap to display the state 4 Go to Font Tab Fill in the Color and Font attributes of the displayed data 5 Click OK to place the ASCII Input Extend part on the window The memory way in ASCII Input Extend is explained as follows I Attribute Adjust Choose Left When input character A A The Highest Word
106. ead address amp Wrte address are the same M10 Window 10 Push the Toggle Switch Read address and Write address to all turn into ON Procedure to place a Direct Window 1 Click the Direct Window Tool 2 Fill in General Tab Items The Direct window Read address 210 the window number is 20 Create Direct Window Object ooo General Description Head address a Device type LB we Device address 100 Window Mo Description A reference name that you assign to the Direct Window not displayed Read Address Bit in the PLC that calls the Direct Window Window No The window number assigned to the Direct Window 3 Click OK to position the Direct Window where you want it to pop up and resize The size of the window limits the area of display The window area outside of the window boundary is clipped Function Button parts Window Bar and Minimize Window can be assigned to the window to enable repositioning and minimizing Refer to Window Bar and Minimize Window in the Function Key Part section 6 18 Alarm Scan Ed aam Messages are displayed on Alarm Display and Alarm Bar parts The message to be displayed must first be registered in the Alarm Scan list A bit controls each message If the bit activates the alarm ON or OFF the corresponding message is displayed This object is only for alarm register Procedure to add
107. ead address Device be Device address No ot voris a Trigger address Device type Device address S000 Apply Create a ASCII Input Extend and a Numeric Input Extend to display and amend the recipe data in PLC ASCII Input Extend Objects Attributes A Numeric Input Extend Objects AHribntes General Shape General Numeric Shape Read address Device type Device address Vo of vods Trigger address Device type Device address S000 Ax Attribute iin Read address Device type Device address Vo of won Aux Trigger address Device type Device address S000 Create two recipe transfer objects one is for downloading recipe data and another is for uploading recipe data Eecipe Transfer Objects Attributes Recipe Transfer Objects Attributes General Shape ile General Shape Description Description Write address Write address Device type Device address 100 Device type Device address 100 No of words ors No of words Attribute Attribute Direction Direction Then we design two buttons for users to conveniently look up and amend each set of recipe data one is for looking up forward and another is for looking up backward We set look up forward as a multi state switch object Every time when you press this object system deducts 5 from the value of LW9000 Because each set of recipe data includes 5 words RWIO displays the previou
108. ead or write address The valid device type and address range depends on the individual PLC type Create E Fun S US Object General Shape Label Device type Device address D E Write addres Device type Device address oO Attribute Select appropriate PLC type in the system parameter menu system Parameter Setting PLC General Indicator Security Editor Hardware Aux PLC type MITSUBISHI FEX n FXZ d MemoryMap Slave MITSTIBISHT 18 HMI model MITSUBISHI AZA MITSUBISHI ATUS MITSTIEISHT 2N A18H PLO UF port MITSUBISHI al Dats bite MITSUBISHI AT l AnA AnU CPU MITSUBISHI FXUn 2 2n COM Mee ii TEDIN Petes Stop bits FP TTSUEISH Fin _ MITSUBISHI EX2n Dibit POS V1 00 Parameter 1 TTStBISHl 2 8100 MODEMS BTU Modbus E TU Extend PDS 3 02 MOD DEUS EIU Server MODBUS ETU TC MODE PDS 1 00 MODBUS ETU TCHIP HMI station no MODBUS RTU 485 2W LIS OMRON OMRON CIACS1 PD v2 01 Multiple HMI OMRON ESCN PDS Y1 01 OMRON 485 2 115200 C tle P MAC Cie SATA PCD PGU Mode PD 1 00 Local eal PCD BUS Mode PDS 1 00 samsung oPC 10 SHARP TW Series PIS 1 00 server IISTEMENZ S7 200 SIEMENS 87 300 HMI Adapter SIEMENS 27 300 PC Adapter Default route IF address o mmy m PLC time out constant sec PLC block pack The device type field will indicate all possible devices available Parameter 3 Parameter 5 Create Set Word Object
109. ed in a double word If a multi state object uses a word to indicate CV2 showed as below Create Set Word Object eneral ehape Liescription Write address Device type erem Attribute Set style Set valne When the compile level is at level 0 the compile system ignores the mistake However there would be unexpected error when the compiled project 1s run on the HMI When the compile lever is at level 1 the compile system will detect the mistake Level 1 is suggested Part Layout Select Control to have the part move to the topmost layer and become visible Select Nature to have the part stay in its original layer still changing state though partially or invisible Address Mode Standard Used when a touchscreen 1s connected to one PLC Extended Used when a touchscreen 1s connected to more than one PLC Explanation about Extended Address Mode The application of Easy View HMI can only be via RS 232 or RS 485 and a PLC line in the past Joining the function of Extended Address Mode in order to overcome this restriction users can realize this function via the interface of RS 484 the following picture shows MT500 PLC RS 485 Serial Port RS485 9P D SUB Male Station NO Q serial Port RS485 Station NO As to user it is essential that PLC that can be controlled more than 2 by a HMI is used in some detail how to realize this function as follows 1 Can support PLC of Extended Address
110. ed of picture of accelerating like this 6 24 Event Log Event Log Messages are displayed on the Event Display Part The message to be displayed on the Event Display must first be registered in the Event Log list A bit or word device controls each message If the bit or word device activates either ON OFF or value limit the corresponding message is displayed in the Event Display This object is just for logging in the event Event is displayed from Event Display Procedure to add modify the Event Log 1 Click Event Log Tool Event Log Object Address Trigger Condition Content 0 LBIO On None LB10 ON Please C IERI gt j The temperature E setting Close 2 Select the Add button to add a new message or select Setting to modify the current information 3 Hill in Attributes Dialog Address type Select Bit or Word address type Read Address Specifies the PLC bit or word address that triggers the message Attribute Event trigger Bit Address type ON displays message when bit is ON OFF displays message when bit is OFF Event Log Object s Attributes Address type THESE Head address Device type LB vi Device address 30 IUS Attribute Event trigger On Off Print L On trigger Return to normal Category o Text Content The temperature is higher than 0 degrees H Color Font 24 Use label library Label Library Write value Words Ad
111. ed to trigger data transfer to and from the PLC PLC Control Object s Attributes Description Read address Device type LW v Device address 0 BN v Attribute Type of control General PLC control Macro name There are four transfer directions 1 PLC RW Recipe Data Register Read address value 1 2 PLC LW Local data memory of touch screen Read address value 2 3 RW Recipe Data Register PLC Read address value 3 4 LW Local data memory of touch screen PLC Read address value 4 Concrete to prove as follows Control the component while establishing the communication frame to choose location General PLC Control to control in PLC read type and address of choosing the control register used in the address column pay attention to regarding single charactering Word as the unit the system will be automatic planning controls the data and chooses the register address in order that data transmission control the register as four continuous data registers of the start address with PLC that 1s established their concrete meaning and operation method are as follows 1 Establish the address of reading He expresses the type of data transmission carried out as stated have four kinds in all used for storing and controlling the code of the type in this register when the register is written into the new control code the system carries out corresponding transmission promptly this regist
112. en window Easy Builder provides a good way in the Object Treebar to display the PLC address of each object Click on the Objects Tab to view all the objects and of which corresponding PLC address on the Window number being displayed Click on an object No in the Treebar to highlight the object The object can be positioned and edited Double click on an object No to pop up the attributes dialog of the object To hide or display the Object Window Treebar Select View Object Window Treebar or simply press the Tab key 6 Cursor Position 179 1533 234 208 MITSUBISHI Fz njFx2 width 56 Height 56 Shows the current cursor position on the active screen and assistant statements 3 5 5 Menu Option 1 Grid Snap Grid is composed of many pixels on the screen for the alignment of the object Enter X Y pixels to change the grid density Select Display checkbox to enable disable grid visibility Note The grid isn t showed on the screen after a downloaded Select Option Grid Snap the following pop up dialog appears Grid Snap Settings Spacing X 3 60 7 Ww Display Snap Y 360 20 Fix objects Spacing Enter the space of the grid Unit is dot the default are 20 dots in both X and Y EasyBuilder 500 User s Manual Display Enables Disables grid visibility Snap As choose snap the mouse s cursor position is then fixed according to the screen s grid points relieving you of the need t
113. er will be restored to the throne is 0 soon after transmit and finish 2 Establish and read address 1 It shows the size of one of the data transmitted namely the number of words of one of data transmitted 3 Establish and read address 2 It shows what needs paying attention to in skew amount of the data register address of PLC in the transmission course 1s that this skew amount is to in the register establishing and reading address 4 And the the speech one for example regard OMRON PLC as for example fruit PLC controls the address of reading established interchangeably in the component as DM100 and the start address of one of data of PLC operated while the data in register DM102 are transmitted for 4 is DMIOS 1004 44 4 Establish and read address 3 It expresses the prescription data register of the touch sensitive screen in the transmission course RW or local address skew amount of data register LW skew amount for example above if data of DM103 100 in giving an example data of touch sensitive screen of transmission course start address of piece RW LW 100 then 04 100 Lift the instance of using as follows Is it control with PLC data transmission of word is it touch reject data of filling a prescription of the register a initial one the same and heavy with RW200 to get DM100 initial 30 of OMRON PLC to need now In little data one the method to realize 1s as follows 1 supposes at first that we control transmit
114. erence name that you assign to the Trend Display not displayed Pen attribute Specify the Trend Color and pen thickness for the channel Value Set the zero and span for each channel 4 Click OK to position and resize the Trend Display Now come to do a form page trend display and example of many page trend display separately 1 Single page trend display Newly build a project and save at first In editor systematic parameter in set up by correct one PLC the types and parameter Add a form page trend display object Its time of taking a sample is one second it is 10 to take a sample and count it is 4 that the orbit is counted the following picture shows Trend Display Objects Attributes General Trend Profile Page type Eim ieme Sampling time seconds Plot point 1U Head address Device type Device address Ho af channel In trend display in set up 4 channel because separately it blue for the trajectories the red the green purple Minimums are all 0 the maximum is 500 1000 respectively 1500 2000 Adjust the size of the trend picture component Add 2 scale object one is horizontal one is vertical their partition is all 20 Add 2 scale object one 1s horizontal one 1s vertical their partition 1s all 20 Hand in them to transform into the net together and pay attention to above object pile of trend display The size of these 3 object 2 scale and a trend picture m
115. ess BIN ird Ma of words write address Device type D v Device address BIN v Mo of wards Attribute Switch style JOG v Mn of states Procedure to place a Multi State Switch 1 Click Multi State Switch icon 2 Fill in General Tab Description Reference text assigned to the Multi State Switch not displayed Read Address Word in the PLC that controls the Multi State Switch state shape and label Data in the register transfer to Binary or BCD format Write Address Word in the PLC that is controlled by the Multi State Switch Style Data in the register transfer to Binary or BCD format No of words is restricted to 1 No of states The number of states is restricted to a maximum of 32 states The value of 1 means one state only 3 Go to Shape Tab Select Shape or Bitmap to display word states 4 Go to Label Tab Fill in fields to denote states 5 Click OK to place the Multi State Switch part on the window Position the Multi State Switch part and resize it Switch Style Functions JOG The value in the designated write address 1s increased by one when the Multi State Switch is pressed If the value is equal to the No of states o is returned to the register The value in the designated write address 1s decreased by one when the Multi State Switch is pressed If the value is equal to zero 1 is returned to the register 6 7 Function Key a Functi
116. evice address 3000 Cancel Apply After creating Save Compile On line Off line simulation or Download the display shows as below When Numeric Input object is activated function keys FK 0 FK 14 become Numeric Input keypad EasyView 6 7 10 Message Board Please refer to Ch 9 6 7 11 Print Please refer to Ch 11 Print 6 8 Moving Shape Fal The Moving Shape tool is used to place an object in a window at a location specified by the PLC The state and then absolute location of the shape in the window depend on the current values of three continuous PLC registers Generally speaking the first register controls the state of the object and the second one controls the horizontal position X and the third one controls the vertical position Y E The coordinate A position 15 controlled by PLC Procedure to place a Moving Shape 1 Click Moving Shape icon 2 Fill in General Tab Items Create Moving Shape Object General Shape Label i Description J Head address Device type Lw w Device address o BIN m Attribute Style X axis only Mo of states 1 E v Input low Input high 1 Description A reference name that you assign to the Moving Shape not displayed Read Address Word in the PLC that controls the Moving Shape sta
117. ew500 software There are three modules in the whole Easybuilder500 EasyDownload Upload amp Download EasyWindow On line Simulator amp Off Line Simulator and Easybuilder Easybuilder 1s the software for editing used for planning various kinds of component positions generally abbreviate as EB500 You can download and simulate on line or off line by using EasyManager that 1s realized by the way transferring other two mould groups via EasyManager Don t need to open EasyManager window downloading or off Line from EasyBuilder But you have to set up related parameters on EasyManager ex COM port communication speed otherwise the operation may be unable to run The structure relation diagram of EasyManager depicts as below EasyManager TacyManaper a i4 cou Wilrssooaps B EasyDownLoad EasyWindow EasyBuilder Project DowmnlnadfUplosd Complete Downloadfplaad Select Start All Programs Easy Builder EasyManager the popup C omnes e EasyManager dialog appears as below Download EasyManager has the following components L upload In EB500 the communication parameter between the computer and HMI is defined as follows Jump To Application dump Ta Tauch Adjust COM Port Drop Down Box Direct Online Simulator Select the number of the RS232 Serial COM port COMI or COM2 for L e computer Ports COM1 through COM10 are available for selecti
118. f conversion and decimal point etc have selected and has been all neglected XXX X Create Numeric Input Extend Object r General Numeric Shape Fant Display O Decima Hex Binary Mask Single float Dauble float Humeric Mo above Dec 4 Input law Input high 100 Single float Data in the controller is translated from a 32 bit IEEE Floating Point format to a decimal number and displayed Double float Data in the controller is translated from a 64 bit IEEE Floating Point format to a decimal number and displayed At the time of the data entry of the decimal system if choose to show initial data input the minimum and input the restriction range that the maximum will be regarded as the effective data in if choose the project data are changed the project changes the maximum and project and changes the restriction range that the minimum will be regarded as the effective data in Do conversion so Input data Engineering low Input high Input low PLC value 4 Input low Engineering high Engineering low Single float format 32 bit s ewm m 30 S 31 23 22 0 0 lt e 255 CD x2 xl1f e 0 f 0 1 x2 xof S Double precision float format 64 bit s aes mus mt 0 S 63 62 52 5l 32 31 0 lt e lt 2047 1 x2 x 1f e 00 f 0 1 x2 xO e 0 f 0
119. h area EEE e EEE EE io Use the customized keyboard data in Procedure to place a Numeric Input Extend Create Numeric Input Extend Object General Numeric Shape Font Description Read address Device type Ly v Device address 0 BIN v Ma of words 1 Trigger address Device type LB w Device address q 1 Click Numeric Input Extend icon kl 2 Fill in General Tab Items Description A reference name that you assign to the Numeric Input Extend not displayed Read Address Word in the PLC that is displayed and modified by the Numeric Input Extend Tab The data is changed to Binary or BCD format Please refer Word Lamp The number here is limited to 1 16 Bits or 2 32 Bits Trigger Address Bit in the PLC that controls the ability to enter data into the Read Address If bit is OFF data entry 1s disabled 3 Fill in Numeric Tab items Create Numeric Input Extend Object General Numeric Shape Font Display Decimal Hex C Binary Mask Single float Double float C Raw data display Do conversion Humeric Mo above Dec 4 EI Mo below Dec Input high 3595 Display Control the format of the data display See the context as below Numeric Set up the position of the Decimal point and the Max and Min value 4 Go to
120. he PLC HMI HMI link speed This is used only when a serial interface is used for connecting multiple HMIs Set connection parameters Multiple HMI Set the HMI directly connecting to MT500 display as the mater and set the rest of the displays as slaves HMI HMI link speed 38400bps and 115200bps are available Please consult the appendix II relevant content about Multiple HMI PLC time out constant sec This setting determines how long the HMI waits for a response from the PLC If the comm delay time of PLC is longer than time out constant PLC NO Response message appears no the display Typically the PLC time out constant is set at 3 0 sec PLC data package HMI will collect all PLC data with continuous address and send an order reading to read these data automatically this has improved communication efficiency and reduced the response time greatly But if the addresses of these data are discontinous then HMI will read these data through the single order then need reading the order to read these data of a lot of It can allow two addresses to have intervals even two data with discontinous address to set up this parameter so long as this interval is not greater than this parameter HMI can still use one to read the order to read these data from PEC Give an example as follows As left picture shows will read the data from D20 to D29 when PLC data package is set up as 0 system use 3 read order 1s it read data to come
121. he range of the input data is 0 1000 and the value written in the PLC 1s 0 100 namely for relation of 0 1 times should set up as follows Input lower limit O Input upper limit 2100 Engineering low 0 Engineering high 21000 the following picture shows Create Numeric Input Extend Object General Numeric Shape Display CO Decima Hex Binary Mask Single float Double float CO Raw data display Do conversion Numeric Mo above Dec Mao below Dec n Ss Input high 9999 Input law Engineering high 1000 Engineering law Hexadecimal The number is displayed in hex 0 9 A F format Scaling is disabled Create Numeric Input Extend Object General Numeric Shape Display Decimal 9 Hex C Binary Mask C Single float Double float Numeric Mo above Dec lt Binary The number is displayed in binary O amp 1 format Scaling is disabled Create Numeric Input Extend Object General Numeric Shape Font ia Display O Decima Hex Binary Mask Single float Double float Humeric Mo above Dec aoo an Input law o Input high 100 To Hexadecimal number system and the binary scale form inputting the maximum and inputting the minimum regards as agreeing with the binary scale data Mask Displays only and ignores the reading value This is used for security code input Its proportion o
122. ht or left side of the display Background color Select background colors from the drapdown Text Determines text alignment within the Task Buttons Alarm Bar The Alarm bar Part displays alarm text 1n the form of newsbar Pixels per scroll Select 8 16 24 or 32 from the drop down menu This specifies how many pixels are scrolled in each increment The larger the number is the faster a given message 1s displayed Scroll speed This setting determines how fast each increment of the scroll is displayed The larger the number is the faster the information displays No of windows This setting is used to specify the maximum number of windows allowed open at any one time If printing function is used the maximum number is 5 If the compressed object 1s used the maximum number is 4 Password It locks the project after it is downloaded so it cannot be uploaded without first entering the password Password should be enter when upgrading the ROM in BootRomUpdate Startup window No This is the window displayed when the HMI is powered up Back light saver The HMI turns off back light power if there are no touch operations within the set time Range 0 to 30 minutes A zero setting disables the back light auto shutoff function Cursor color Determines the color of the cursor when activate the input of numbers or words Buzzer The buzzer sounds briefly every time the touchscreen is activated by touch This selection allows
123. iate corresponding icons E Elti nli 9 Make same size When multiple objects are selected they can all be fixed to the same size by using the Make same size function Objects can be made the same width height or overall size It can be done from the Edit menu Make same size submenu or by clicking on the corresponding icons H FH 10 Transformation The one that can be turned is only a figure drawn with the drawing tool such as the straight line round polygon etc other components can not be turned Select the object and the object transformation can be done from the Edit menu Flip Vertical Flip Horizon or Rotate 90 degree items or by clicking the corresponding icons EI 4 d l Flip Vertical Flip Horizon Rotate 90 degree 11 Group Ungroup Grouping Ungrouping multiple objects or shapes can be called by this function Grouped single objects can be used as a object or can be saved to the library for next time use Click Hi icon to gather multiple objects and click Es icon to break up a group into its separate objects Select Library Group library Save to group library to save the group 12 Redraw Window Redraw the window to show again the corresponding icon 1s 2 13 Select All Objects An object can be selected by clicking W icon in the drawing tools or selecting Select from the Edit menu EasyBuilder 500 User s Manual There are 3 types of selection 1 Select Select
124. ick Open Here we choose the existing a eob file and a pop up screen appears as follows EasyBuilder 500 User s Manual Realize on line simulation like this 2 On line simulation under EB500 Open EB500 and open the project you are going to simulate Select Save Compile in the Edit menu and select On line simulator in the Tools menu or click icon 3 7 Off line Simulation EB500 supports Off line simulation Off line simulation will not get the data from PLC read the data only from the local address so all datas are static Off line simulation can be execute from EB500 or from EasyManager From EB500 Save the file first and then compile it Select Off line Simulator from Tools menu or click icon to run the simulation From EasyManager select Offline Simulator to emulates the operation of a project on the PC screen 3 8 Assistant Tools Easy Builder500 provides a set of powerful On line Off line Assistant Tools Right click anywhere in the simulation screen the pop up menu appears EasyBuilder 500 User s Manual The following explain these functions in detail 1 Search Click Search the following pop up dialog appears L Lad Check PLC checkbox and input PLC device and the range of the address Click Search which shows all the objects using the specific PLC address EasyBuilder 500 User s Manual OF 0 OHU A LL PUT 0 ObQDUA Ad UDUT 2 01 SenAterd wen ojona AAD 1 01 Sette Wie O02 0 amp ajna
125. ime tag to Days Hours Minutes Error Detection Neglect the wrong signal for example lacks the paper of the printer or the transmission that has been keeping typing the data all the time until the wrong signal has been removed No error detection Printer errors are ignored Message board window No Select the window number to be used as the message board Regarding to Message board please refer to ch 9 Message board 7 3 The Indicator Tab system Parameter Setting PLC General Indicator Security Editor Hardware Aux Touch indicator Attribute Di Non confieured area Active area E Inactive area Frarne M CPU indicator Attribute Color Alarm indicator Attribute ETE Ev Color Ean Touch indicator The Touch indicator changes color every time a screen touch is touched Attribute Enable makes the Touch indicator visible and active Disable makes the indicator invisible and not active Non configured area Active area and Inactive area Set the touch area s color that is displayed in Touch indicator Non configured area Set the color of the Touch indicator when the Non configured area 1s selected Active area Set the color of the Touch indicator when the Active area is selected Inactive area Set the color of the Touch indicator when the Inactive area is selected Frame Set the color of the circular outline in the Touch indicator CPU indicator The
126. in nodal switch location address After a waming information is produced must be when this location address is switched over to the non warming state again this waming information will just be dispelled automatically otherwise waning information will show dl thetime namey in waning state dl the tme this component only shows warming information must be by the component wanted to show in component log in of waming infomraion log in Procedure to add Alarm Display 1 Click Alarm Display icon 2 Fill in General Tab Items Create Alarm Display Object General Description Read address Device type Law s Device address 0 BIN v No of wards 1 Attribute 2 Display line 5 w Char length 5 Description A reference name that you assign to the Alarm Display not displayed Read Address The Read Address controls the scrolling up and down of the alarm display window If the read address is N the information of N 1 is ignored and displays the information of N on the first row Data format BIN or BCD No of words fixed to 1 Display line Assign the number of lines to a window unit 16 pixels Char Length Assign the number of characters to a line unit 8 pixels For example The font of the characters are 24 24 24pixels Display line is 5 Char Length is 30 Enter the material mistake The Lirection is changed unusually 3 Click OK to place and position the Alarm Display where desire
127. indow number object number Object object name Access Type Visit way Read or Write Address Type Device name Address Device address Data HEX low byte list first Data 5 Emulator Setting Select Emulator Setting to set the simulation display Dim GLa bor a Ting px PF If bitmap background mode is selected the display is as the following EasyBuilder 500 User s Manual EasyView EasyView 500 Operator Interface If bitmap background mode is canceled the display is as the following EatyWindow 7 1 C Wocuments and Sottinps poyiecktopW 770 rajectWA T5OOTA E LJ x PIGH OUGITSG EET Desham 01 5 Or Later Required MH Irfonason Dee WE DO Cal All the displayed are the same On the right of the Object Information the types of the object are set on the right Address Object Frame Small Font Transparent Object ID Common Window If Address Object Frame and Object ID are selected the display shows as below EasyBuilder 500 User s Manual EasyView Tir Tir Tir Tne Tits ELI TY TT if LHAT Tice ll HIR ees XE kx iix Ribes 6 Print Print Screen Print the current screen Print Screen Preview Print preview the current screen Print Screen to File Save the current screen as a bmp file Print Window Print the current window s Print Window Preview Print preview the current screen Print Window to File Save the current window
128. is an example of an animated object Add an animated object as following Read Address LW1 bin format No of state 4 Shape selection State 0 State 1 State 2 State 3 9 9 9 The predefined path as below Karyllgilder amp Y Agimatson TT LISTE 10 lothal Scorer tB Bie Eie Yew pion we fun Lbay ook Hide Heb Do E Bo 2 x XM SB eee Aes FO 4 A i Th A OU oF 34 5 amp HW 93 30 13 17 173 34 15 36 17 1H 19 20 21 22 73 24 25 25 27 28 29 X 36 Sme U k b Fact Sealer hon g 5 Cimmi Wire ij IO eas Sr 11 UTULAU me IOSkr RRA s LI e P Bir c hose 1 When LW 1 0 LW2 0 2 When LW 1 1 LW2 1 EasyView E EasyVi ew Point 1 Point 1 Point 4 Point 3 Point 3 LW2 8 3 When LW 1 2 LW2 2 4 When LW1 3 LW2 3 EasyView m i R EasyView Point 1 Point 4 Point 1 Point 4 e Point 2 6 10 Numeric Input Extend EEF EE A Numeric Input Extend Part displays the current reading of a designated PLC register data and the data in the register can be changed by keypad If the Trigger address bit 1s active when the area of the shape is touched a flashing cursor indicating input via keypad is activated Use an already displayed keypad made of function keys to enter numeric data to the PLC register Show present EI1 234 number value Activate touc
129. isplayed Read Address Word in the PLC that controls the Animation state position and label Read Address 1 is the word address to control the position The data in the register 1s defined as Binery or BCD format The number is limited to 2 here No of states Select the total number of states for the object This determines what state of the shape or bitmap is displayable at stops along the path 5 Go to Shape Tab Select Shape or Bitmap to move and display states 6 Go to Label Tab Fill in text to denote states 7 Go to the Profile tab The Profile tab settings shows as following Animation Objects Attributes p General Shape Label Protile Position Pined x 132 3 E Size Width 242 3 Height 137 Shape rectangle size Width 55 Height 56 Point x 155 B Position The location of the upper left hand corner of the Animation area Size The dimensional area on the screen that the outside edge of the path occupies Shape Rect Size The area of the shape or bitmap that is used in the Animation Points 0 1 2 3 The track can be repositioned by selecting the point number Point 0 is the first point of the path point 1 1s the second point of the path and so on X Y are the corresponding coordinates 8 Click OK to complete the setup Assign the read address Read Address Shape or Bitmap State Read Address 1 The potision number on the predefined path The following
130. language type 3 5 6 Menu Draw 1 Line Rectangular Ellipse Circle Arc Polygon EasyBuilder 500 User s Manual Attributes Interior Interior 9 Fea Pattern NENNEN gt _ Pattern style Frame Color gt E Bo Bees EI e E lee The Frame attributes are used to set how the lines for the object are displayed Select Line types There are eight selections for the line or frame width Select a Color Select a color from the 256 color selection The Interior attributes are for objects that can be filled For objects that cannot be filled this option is disabled The filled attributes are not displayed if the Filled check box isn t selected If the Filled option is selected the following attributes can be set Select Interior colors Select a color from the 256 color selection Select Pattern There are 26 different patterns available in the Pattern Style Pattern Style Be Pah tt Ht Ht i 777 WN 5554 ESSSSSS ES RSS L1 LLL p ons ee ee ee L The Pattern Style dialog pops up when the Pattern Style button is clicked Note The color window pops up when a color selection dialog is activated One of the standard colors may be chosen or click on Customize color to access a full spectrum of color options Color Table ooo EEL EC E CH E EL EL EL EI KE ESI EC EZ A EC EZ EE E ERI ERI EI ERI EI EE REE EEL I J 10 1L E EasyBuilder 500 User s M
131. layer 4th layer 5th layer 6th layer Carry out the order of Y5 finally Control YO to open close at first then control Y1 to open close the second step control Y2 to open close the third step Control Y5 to open close the 6th step User must pay attention to one point When MT500 meets and switches over the basic window order it will neglect in the component of this component ground floor and switch over to the goal window directly The following picture if Y2 in order to switch over the basic window function key then the following Y5 of Y3 will be neglected First layer Carry out the order of YO at first The second layer Carry out the order of Y1 The third layer Change Base Window Ath layer Neglect 5th layer Neglect 6th layer Neglect Proposing object that is superposed the figure don t be over 32 Chapter 7 System Parameters 1 Filling in the system parameters Select the Edit System Parameters menu and the System Parameter Setting dialog appears as below View Option Draw Parts Window Copy Paste Colt Find Replace Addy Ctl H Layer Hud ge Alien Make Same bize wr F F F Redraw Window select 4l Objects w select swvetem Parameters system Parameter Setting HMI model MTSIOTAMTSOST 540 x 480 V PLC LF port RZ 485defaultt Baud rate 9600 Data bits 7 Bits v Parity Even Parameter 1 Parameter 3 Parameter 5 HMI station no
132. lds to denote states 5 Click OK Position the Set Bit part and resize it Set Style Functions Set ON at window open Set OFF at window open Periodical toggle When the Set Bit Part is pressed the designated Device address is turned ON The state continues keeps ON even after release When the Set Bit Part 1s pressed the designated Device address 1s turned OFF The state continues keeps OFF even after release Every time the Set Bit Part is pressed the designated PLC bit is complemented ON gt OFF OFF gt ON When the Set Bit Part 1s pressed and keep holding the designated Device address 1s turned ON Whether when the Set Bit Part 1s freedom the designated Device address is return OFF When the window containing this Set Bit Part is opened the designated PLC address 1s turned ON When the window containing this Set Bit Part is opened the designated PLC address 1s turned OFF Changes the state of the designated bit at a regular interval as selected in the Interval dropdown Set ON at window When the window containing this Set Bit Part is closed the designated PLC address is turned ON the operation is suitable for Local Bit or LW Set OFF at When the window containing this Set Bit Part 1s closed the designated PLC address 1s turned OFF the operation 1s suitable for Local Bit or LW Set ON at window When the window containing this Set Bit Part is maximized the PLC maximized Device address is turne
133. meric Data Object General Numeric Font Read address Device type Device address 9042 Aux The whole project is as follows L EasyBuilder security level epj Window 10 Initial Screen EIE EB File Edit View Option Draw Parts Libary Tools Window Help 8x Do 62 890Wwt ux UM EB mE gt BAB 100 v Laguge v FONT 24 vi AX ES 2 B 7 SER HAEA E s g ml nm Em 4 de 0 12 34 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 State 0 J 2H E u QOL 7z lz 4 Fast Selection H 6 Common Window 10 Initial Screen ND 0 LY9042 Bottom L TX 0 Window 10 TX 1 11 WINDOW 011 current security level ig FR B sU zm aw 8 ce BIBBIBL Me CuurBbe ge Geis 5 bb S S al J F lt gt For Help press F1 MITSUBISHI FE n FX2 X2358 Y 244 Save compile and Off line simulation Window 160 current security level Easy Uieu Because there s no password input the current security level must be 0 Now create a window 11 and set the security level for 1 Window Setting Name CT DIRMI Window no 11 Start Pos x ll Size Width 640 Height 480 Style Tracking Monopoly Clipping Coherence security level Lowest Underlay window 1 None Frame Width 4 Background Color MEE Pattern Filled Pattern color BENE Create a function key on window 10 the a
134. mplate506t Print Setup per ETOR AESH la 2 EBPrjl a 3 template520p File name EEFI 4 ASCIIFont A Save as type EasyBuilder Files epi hal Exil Input new project name to save the new project 6 Exit Exit EB 500 7 Current opened files Four current opened files names and paths are showed in the File menu Click any file name to open the file 3 5 3 Menu Edit 1 Undo Undo function cancels the latest operation and go back to previous condition Press ER icon or select Undo from the Edit menu to cancel the latest operation 2 Redo Redo function revert current operation to previous condition It s done by pressing ES icon or selecting Redo from the Edit menu Undo Redo function is used in adding or changing any object on the screen Add one object as the diagram EasyBuilder 500 User s Manual Las aloe des IU TEE LUTTE D Ind TET EB Fi Ede ums Coton Dee Patr D eany Teese Wwe Hep Dad tee TUM F ail bed E ub wm AANA XE oe Langue Ta Th S HUBER t ot aad FT 8 959 W TI 17 73 14d T5 35 17 M 03 70 21 77 73 74 75 28 7 7 78 732 00 31 Sic ET E lI Ls hi rre L nib 5 3 ul Click Undo La ale dej I LK Wed Tcl Ind Em iien EB Pie hE W Cetin Cre Patr Livery Tac Wira Hep O o uw a D ki v 34 Jl al a EB al faa E A A i iai X Lengua ui z2234 58 T B 9 Wi 0 d 17 d4 d5 AT 38 77 70 Z1 zz 3 r4 5 8 o D
135. n key only it is touched off by PLC register but not touched accusing of operating and touching off When the value of reading the address 1s changed into a new effective window serial number will close the window at present and show the window appointed from the address of reading then the content of reading the address will write and read address 1 This is operated and will when change in value that read address only be touched off and this value changes once and can only carry on the screen once to switch over Back light control The function turns the display s backlight OFF when the Read address turns ON When the backlight is OFF a touch reactivates the backlight PLC Control Objects AHributes Description Head address Device type v Device address 0 Attribute Type of control FERAM en ud Macro name At this time the state of LBO is ON Retouch LBO turns the state to OFF so that the backlight goes back to the previous state Screen hardcopy The function use a Read address to control the printout of current screen If the bit 1s triggered from OFF to ON the current screen is printed out Set the valid printer type from System parameters General Screen hardcopy Please refer to the context of Screen hardcopy on Ch 11 Report printout Prints the screen number designated by the Read address After the screen is printed the Read address 1s set to O Please refer to the context of Report printout
136. ndirect Window Direct Window Alacmn Display Trend Displaw XY Plot Bar Graph Meter Display Alarm Bar Recipe Transfer Event Display oic BiB EEL zd IR afl Alarm Scan s vestem Mesage PLC Control Event Log Data Transfer je Nc 3 After the attributes setting click OK place the object on window If necessary adjust size or drag it to new position 9 2 ID Number An ID number is assigned automatically to a part The number identifies a specific part on the current window The programmer can not change the ID number ID Number a WL 001 O Indicates part is SELECTAE Word Lamp for the part BL Bit Lamp WL Word Lamp SB Set Bit SW Set Word TS Toggle Switch MS Multi state Switch FK Function Key MV Moving Shape AN Animation NE Numeric Input Extend ND Numeric Data AE ASCII Input Extend AD ASCII Data BG Bar Graph MD Meter Display WP Indirect Window WC Direct Window AL Alarm Display AS Alarm Scan TD Trend Display XY XY Plot SM System Message RP Recipe Transfer EL Event Log ED Event Display 5 3 Attaching a Description If desired a comment can be attached to a Part This is a good practice for future referencing and useful when deciphering a printout of project files Create Hit Lamp Object General Shape Label Description Description about Bit Lamp Object Eead address Device type Device address 5 4 Entering a PLC r
137. ndow 12 Place a Set Bit Object and a direct window Direct window is set as a full screen and the setting of the Set Bit Object are as following Create Set Bit Object eneral shape Write addres Device type Device address Aux Attribute eble Set ON at window open b The setting of the direct window 1s as below Create Direct Window Object Read address Device type Device address Iu O Aux The setting of Window 11 C EasyBuilder EBPrjl Window 11 WINDOW 011 EB File Edit View Option Draw Parts Library Tools Window Help DEH tbee I R h zx ab SB Awe EL BI 1009 v Languageo v zz wt Me sade d Ld 4 Fast Selection es Oy m 6 Common Window m 10 Initial Screen H N SB LBl Bottom Layer 5 WC O LBD T esl 1 WINDOW 011 gt Tal O TX_O Bottom Layer amp SB D LBO c WC D LBD Ed Bi A 12 WINDOW 012 sto ke ise HB alt aia mg O xx m m E mm Has Qul MITSUBISHI FX n FX2 X 286 Y 18 Write addres Device type Device address ln Of Ap Another direct window Create Direct Window Object Read address Device type Device address n O O Aux A other one some object that static behavior show you can establish at will The setting of window 12 the size of window 12 should be the same as the window 11 1 Fast selection H 6 Common Window 10 Initial Screen eb ALE
138. ng applies to the MT51OT only It allows the user to change the PCD of the display The PCD is related to the scan frequency of LCD Low PCD is suggested System Parameter No Don t stored the system parameters in the retentive memory Yes stored the system parameters in the retentive memory If store function is selected and download the compiled EOB file to the HMI when activate the display for the first time the system parameters will be written into the retentive memory Every time the display 1s activated later the system parameters are retrieved directly from the retentive memory Please refer to Ch 12 for further detail EventLog DataBase No Disables user to keep EventLog information in retentive memory When the HMI starts up or shut down EventLog DataBase information disappears Yes Enables user to keep EventLog information in retentive memory When the HMI starts up or shut down EventLog DataBase information doesn t disappear DataBase Start Address Information is stored in retentive memory starting with the specified address Memory about Eventlog information If choose to be stored in Eventlog column of the systematic parameter systematic to can land time that excite already information store in Recipe Card automatically As to user needn t worry about the problem of how to store of Eventlog information the system will automatically process the course of storing the position that appoints the address of ones tha
139. o control the pop up speed Shape Define the shape of task button or window button just as you would any other button object Label Place a customized label on the task or window button 4 The Screen dialog has the settings for the button that controls the popup Fast Window Screen Athibute General Ene Label Attribute Attribute Show speed Set Fast or Slow to control the pop up animation speed Shape Select a shape for the Screen or Window button just as you would any other button object Label Place a customized label on the task or window button 5 9 Shape Library Open a window and Draw the graphics by using the drawing tools in the EB500 program For example the following graphic uses the line and rectangle tools Select the whole graphic by using the arrow tool and dragging a rectangle around it White handles should appear on all of the selected objects In the Library menu select Shape Save to library or click the2tltool Save to Library Shape library Shape nn State no Description Lib rary Tools Window Help shape save to bray Bitmap Call up library Group F JL Shape Library shape library buton M state 2 Lej 1 jL2j s JL Js JL e JL e o Jojo rz ns ras ne 7 LA dd 40 Untitled 41 Untitled 4 Untitled 43 Untitled LL A 44 Untitled 45 Untitled 46 Untitled 47 Untitled Background Frame Select Lib Unat
140. o make repeated find position adjustments Fix objects Fix the location of the object to prevent objects from inadvertently being moved 2 Window Property Set the environment of the screen Select Window Property from the Option menu Window Property Grid color Display Object ID Using function key to make shape library Jump to application mode when download done J Automatically save and compile when downloading or simulating OK J Came Grid color Set the Grid color Object ID Enables Disables the object ID number from being displayed on an object Using Function Key to make Shape Library Please refer to Library Operations in Ch5 9 for further discussion Jump to application mode when download down Enables Disables automatically forcing the MT500 jump to the application mode after a download Automatic save and compile at download and simulate Enables Disables automatically saving and compiling a project before a simulation or download 3 Language Easy Builder supports several languages Should use the designated language EasyBuilder must be installed under correct Window edition For example should support Traditional Chinese EasyBuilder must be installed under Windows Traditional Chinese edition At the same time must install the designated font Satisfied above choose Language and choose the correct language type in the function form Option in this way can use the suitable
141. on EasyBuilder 500 User s Manual Communications Speed Drop Down Box Determine the communications speed between the PC and the unit during downloads and uploads the 115200 speed is recommended For old style machine or special requirement the 38400 speed is recommended Project Download Upload or Recipe Download Upload Select Project Download Upload to transfer project data Select Recipe Download Upload to transfer recipe data Complete or Partial Download Upload Selecting Complete to download both program file eob and system file bin is slower than select Partial to download just only program file eob When uploading speeds are the same to select either Complete or Partial Easybuilder Easy Builder is the software for editing Used for planning various kinds of component positions generally abbreviate as EB500 Push this button can enter the editing picture of EB500 software Please consult this seal of section five about the detailed introduction to this software Online Simulator Simulator can read the data of PLC through MT500 after a project is compiled by EB500 This creates a file with extension eob and you can operate directly on computer by MT500 Using Online Simulator function saves much time for repeat downloading Please refer to Ch 6 for detail Offline Simulator The Offline simulator emulates the operation of a project on the PC screen which retrieves the static data from display
142. on key is used for changing windows inputting numeric or ASCII codes maximizing minimizing or moving windows designing message board or printing etc Procedure to place a Function Key 1 Click Function Key icon m 2 Fill in General Tab Items Description Reference name assigned to the Function Key not displayed Function Select the type of function 3 Go to Shape Tab Select Shape or Bitmap to display function key that represent the touch area 4 Go to Label Tab Fill in fields to denote states 5 Click OK to place the Function Key on the window Position the Function Key part and resize it 6 7 1 Change Window Change window Retum to previous Change common window Window na 10 If the function key is set as Change Window when the function key is pressed activated the current window display including the child windows of the current window terminates and changes to the window designated by Window No 6 7 2 Return to Previous This function terminates the existing window and recalls the last active window It s valid to Base window Change window Return to previous Change common window For example If window 21 was replaced by window 32 and window 32 has a function key defined as Return to previous then when it is pressed window 32 is terminated and window 21 is displayed 6 7 3 Change Common Window Change window Retum to previous
143. ontrols the Toggle Switch state shape and label Write address Bit that is affected by the Toggle Switch Set Style Switch style See Switch Style Functions below 3 Go to Shape Tab Select Shape or Bitmap to display graphics that represent the touch area 4 Go to Label Tab Fill in fields to denote states 5 Click OK to place the Toggle Switch part on the window Position the Toggle Switch part and resize it Switch Style Functions ON When the Set Bit Part is pressed the Write address 1s turned ON The So state is the same even after release OFF When the Set Bit Part is pressed the Write address 1s turned OFF The state is the same even after release Toggle Every time the Set Bit Part is pressed the Write address state is changed one time ON OFF OFF ON Momentary Only while the Set Bit Part is pressed 1s the Write address turned ON When the switch 1s released the Write address 1s turned OFF 6 6 Multi State Switch E The Multi State Switch is a combination of L paN Word Lamp and Set Word It displays a different state depending on the value of the PLC monitor word address maximum of 32 states It also defines a touch area that when activated writes a specified data to the PLC word address which may be the same as or the different from the Read address Create Multistate Switch Object General Shape Label Description Read address Device type Liw v Device addr
144. or the excellent picture 4 Go to Bar Graph Tab and make settings as below Create Bar Graph Object General Shape Bar Graph Attribute Direction MA Variable alarm N Bar M Background Frame i Alarm Value Low alarm limit 0 High alarm lirnit Zen Span 5 Click OK to position the Bar Graph and resize it if necessary Bar Graph Here we define the direction alarm available or not color and value of the bar graph Attribute Direction Up Down Left and Right Variable alarm Yes The high and low alarm limits are retrieved from PLC data registers as described below They are changeable When the Read Address 1s between the high and low alarm limits the bar graph is in the non alarm situation When it above or under the limit value the graph is under the alarm situation The color displays according to the alarm colors set up No The high and low limits are set from the value of the Bar Graph It s fix after the setting Read Address Bar am data Bar ae data Read Address 2 High alarm 2 Color Set Bar Background Frame and Alarm bar colors Background The filled bar percentage is calculated as follows of filled bar Register value Zero Span Zero 100 Low High alarm limit If Variable alarm is No the high and low alarm limits are entered here 6 15 Meter Display io The Meter displays PLC register data as an angul
145. ords maybe addressed in this manner each word contains 2 ASCII characters 3 Go to Font Tab Fill in the Color and Font attributes of the displayed data Create ASCII Data Object General Font Attribute coor a Font Content 4 Click OK to place the Numeric Data Part on the window 6 14 Bar Graph n The Bar Graph displays PLC register data as a bar graph in proportion to its value by the SPAN and ZERO settings As the pictures below users can design any shape of the bar graph HEN i DEU Procedure to place a Bar Graph 1 Click the Bar Graph Tool the dialog appears Create Bar Graph Object General Shape Bar Graph Description Read address Device type Device address E Mo of words I i 2 Fill in General Tab Items Description A reference name that you assign to the Bar Graph not displayed Read Address The Word that are used to control the Bar Graph display Data format Defines data from the controller as binary BCD No of words Restricted to 1 or 3 Three words are needed when variable alarm is selected The Bar Graph continuously retrieves 3 data words one for data and one each for high and low alarm limits One word 1s needed when fixed alarms are selected 3 Fill in Shape Tab Items to select suitable graph for enhancing the effect of the display Seldom need to dispose the figure f
146. ot point includes the points of two side boundaries If 20 1s selected the screen 1s divided into 19 pieces Therefore 1f the screen 1s going to be divided into 20 pieces 21 should be selected Read address Specify the PLC word address of the first trend data pen the second trend data pen starts at read address 1 and the third starts at read address 2 etc No of Channel The number of PLC data words retrieved 1s the same as No of Channel one word per channel Up to 16 channels can be specified for a trend Scroll control The address of the register that determines which portion of the multiple page display 1s being shown on the screen Each increment of the value in the scroll register moves the Trend display from one sample plot to the left Can set up two pieces of number value and establish the component the equipment address of this component and equipment address which looks through page control are the same Set these first two components as and added one is set as and reduced can be used for controlling the trend picture like this to looked through the page forward and translate pages backward Hold control The bit that controls the trend update See Hold style above Create Trend Display Object a General Trend Description Channel HEN Fen attribute Colr A Value Zen Ho Span 2 Cancel 3 Fill in the Trend Tab Select the Channel to set each channel Description A ref
147. outside the boundary of the indirect window isn t displayed Add function button parts Window Bar or Minimize Window to reposition and minimize the features Refer to Window Bar and Minimize Window in the Function Key Part section Popup windows of Direct Indirect windows A window is controlled by a bit address direct window or word address indirect window Once a bit or a word activates the corresponding popup window appears When the value is zero the window is closed Task bar If have Window bar and Minimize window with the function key at the window sprung then spring a window each time will reserve a little icon for this window on the task bar Push the window little icon at the bar can wave upper strata most to reach the screen corresponding window in task Double click the icon can minimize window is 1t can recover window to the reset condition to hit 6 17 Direct Window E E The Direct Window places a defined child window area over the current window Popup window is displayed within the border of the direct window Typically direct window is the same size as the popup window There s no limit to the number of the direct window However at run time a maximum of six windows can be displayed simultaneously The open or close of the window is controlled by the bit address but not by Function Key When ON is assigned to the bit address the popup window appears retest Window 10 Switch R
148. oving Shape object Only move horizontally on X on the same time Input max or min isn t result The first register records the state of the object and the second one records the position Y axis only The Moving Shape object Only move vertically on X on the same time Input max or min isn t result The first register records the state of the object and the second one records the position X amp Y axis The Moving Shape object move on the both X and Y on the same time Input max or min isn t result The first register records the state of the object and the second one records the position of X and the third one records the position Y X axis W scaling The Moving Shape object Only move horizontally on X the corresponding moving position is set up by inputting data and proportion If the 0 1000 of PLC is read but you want the corresponding position is 0 640 the values of Input low and Input high can be set for 0 1000 and the values of Scaling low and Scaling high can be set for 0 640 The first register records the state of the object and the second one records the position Y axis w scaling The Moving Shape object Only move vertically on Y the corresponding moving position is set up by inputting data and proportion If the 0 1000 of PLC is read but you want the corresponding position is 0 480 the values of Input low and Input high can be set for 0 1000 and the values of Scaling low and Scaling high can be set for 0 480
149. ox for selecting a file appears Select the name of the Group library to be opened Adding a Group to a Library or save an item to Open a window and Draw the graphics by using the drawing tools Also add any parts such as lamps function keys etc For example the group shown to the left uses shapes bitmaps a numeric part and rectangle tools 1 Save group of object to a Group library Use arrow tool to select all the candidate objects on the window Gp korkeina EEG Pred U nil ern EB OSM B85 S69 amp s X uM SB wi 6uB wx v aguge v MT Vw i a Go i i i iz 34 55 f B 9 WW 14 15 16 17 1H T3 20 21 22 23 24 E E Corio Vni k 25 26 SI 278 Z9 30 31 Siete OOO e mnm 3 EE a ES bs dk Ls un ws 5 EN n EH sug EEBZE hal Shetessseuseeris Fer ielp pori Fl MITSUDIEHI Pitted Then in the Library menu select Group Save to library or click amp icon The dialog will appear Save to Library Group library keypad v Group No Select the appropriate Group library fill in the Description and Group No click OK and the selected objects are saved to the group library Group Library Library name keypad w Including library Shape o1o Button 41 A 43 B 40 Bitmap a a F 44 45 AB Af Select Lib Unattach Lib Group Library the content 1s as follows Library Name Select the group library from the dropdown list Inclu
150. pen Window Na Window name Size Fast Selection Tun AJH Common Window 54 411 New Window lnilial Seregi B AHU Setting WIRD DOTT 640 404 LL Murnkeypadl ZH 273 NumKeypad 209 273 Delete Task Butta Select the window name from the window menu to enter an opened window Open Window Cascade Tile Window 10 Initial Screen WINDOW 4 Fast Selection WINDOW 11 WINDOW O11 WINDOW amp Commen Window a a 3 a a Deleting windows 1 On the Window menu select Open Window then choose the window from the list and press Delete 2 Right click the window number in the window Treebar Selecting Delete to delete the window Note A window Delete can t be executed when it s active For example window 11 1s closed so that you can find the Delete selection u p n Lip Window name Size Fast Selection 100 44 on ree Window bAU AHU New VT nad nee mim Initial Screen b AD AHU mE WIND UTT bal EU eting NumKeypod meo Delete MurnKeypad 709 273 Delete Task Button Window 10 1s active so that you can t find the Delete selection L H5 r M uridase Window name nize Fast Selection 100 448 New Window Common Window 540 411 New Window WINDOW UT1 E41 41H eting Numkeypadl 208 273 Numkeypadz 208 273 TaskButton 4 5 Examples The followings are some simple examples of operating the windows Example 1 We need to set
151. pper lirit 0 Break time 0 1 second w Description A reference name that you assign to the Set Word not displayed Write Address Word in the HMI PLC that is affected by the Set Word control Data in the register may be interpreted as Binary or BCD information See note on Word Lamp Part Set Style Please refer to the following graph 3 Goto Shape Tab Select Shape or Bitmap to display graphics that represent the touch area 4 Goto Label Tab Fill in fields to denote states 5 Click OK position the Set Word part and resize it if necessary Set Style Functions Set constant When pressed preset Set value data is written to the designated PLC device Add Value JOG Every time pressed the Inc value is added to the designated word If the result is not larger than Upper limit Sub Value JOG Every time pressed the Dec Value is subtracted from the value of the designated word if the result 1s not less than Bottom Limit JOG When pressed the Inc value is added to the designated word at regular intervals as specified by JOG delay and JOG speed it the result is not larger IE than Upper limit JOG When pressed the Dec value is subtracted from the value of the designated word at regular intervals as specified by JOG delay and JOG speed if the result is not less than Bottom limit Set at window When the window containing this part 1s opened the Set value data 1s open written to the designated word Periodical JOG
152. r Tool or select Recipe Transfer from the Parts menu E 2 Fill 1n General Tab items General Shape Label Write address Device type Device address lo No ofworis 2 Attribute Direction Description A reference name that you assign to the Recipe Transfer not displayed Write Address Word that begins the block of registers to write or receive upload from the PLC No of words How many registers are transferred Direction Download Moves values from the HMI retentive memory to the PLC Save Transfers values from the controller to the HMI retentive memory area 3 Go to Shape Tab Select Shape or Bitmap of the button to activate the transfer 4 Go to Label Tab Fill in fields to denote states 1f desired 5 Click OK to position the part and resize it 8 2 Recipe memory Recipe memory card should be chose for using recipe memory The recipe memory resides in battery backed SRAM The memory contents are preserved for at least half year after power off The battery 1s recharged whenever the system is powered The total size of recipe memory is 64K words There are two ways to represent the recipe memory RW represents absolute address RW 1 represents index address and the number of words you specify in LW9000 offsets an index address from its indicated address For example 1f LW9000 50 an RWI 0 index address points to the address with data 50 If we change LW9000 51 an RWI 0 index address poin
153. r code 0 1 2 3 4 5 6 7 8 9 ENT BS CLR and en the keys in a regular pattern a keypad can be created as below L EasyBuilder EBPrj2 Window 10 Initial Screen EB File Edit View Option Draw Parts Library Tools Window Help Oeil X Saa 2 amp b YV M UA 2 ABB Hale BS Awe 45 zd M E 10056 Language FONT 16 A A S22 8 7 UV m id rH B RB Bg Ie P Fm By o of LL ale TH ts FE LN Te eee ee he Se W ua Wo prece State 0 B F 0D re 4 Fast Selectio 6 Common Mns 10 Initial Screen FK Bottom Layer FK 1 FK 2 FK 3 FK 4 FK 12 FK 13 FK 14 NE O D20 LB9000 11 WINDOW 011 cduH 9d Lok PK_ 0 is created as following Function Key Objects Attributes General Shape Label Profile ENT B5 CLR O ESC ASCII Character Hard copy Attributes Change window Retum to previous Change common window Popup window Close window JOG FS window window bar Minimize window O Message board St operation made Attributes Other function key FK 1 FK 14 are set for ASCII 2 ASCII 9 ASCII O ENT CLRI BS uto 2 Create Numeric Input object Numeric Input Extend EU D T E E DITE CTS General Numeric Shape Font Profile Description Head address Device type D v Device address BIN w Ma of words ALE Trigger address Device type LB v D
154. r corresponding OFF and ON States Create Bit Lamp Object General Shape Label Attribute coo iNNEEEN gt Font Align State Use label Use Label Library Tracking Label Library Duplicate this label ta other states 5 Click OK 6 2 Word Lamp E A Word Lamp changes state according to the value in the designated word address of PLC If the value equals to 0 the first shape is displayed If the value equals to 1 the second shape is displayed and so on The corresponding label for the state is also displayed if Use Label is checked PLC PLC PLC addrwss 0 addrwss 1 addrwss 2 Procedure to place a Word Lamp 1 Click Word Lamp icon Create Word Lamp Object General Shape Label Description Head address Device type Liw w Device address BIN v Ma of words Ma of states 2 Fill in General Tab Items Description A reference name that you assign to the Word Lamp not displayed Read Address PLC Word that controls the Word Lamp state shape and label Data format Defines data from the controller as BIN or BCD No of states Appoint all quantity of states 3 Go to Shape Tab Select Shape or bitmap to display the corresponding states 4 Goto Label Tab Fill in text 5 Click OK to place the word Lamp on the window Position the word Lamp and resize it if necessary Adjust the label position as desired Data format types BIN binary format Decimal n
155. r indirect window This is because opening or closing the direct indirect window is controlled by the bit or word while Close Window function key only closes the popup window but not to control the data in the register 6 7 8 JOG FS Window Popup window Close window JOG FS window Window No 10 This function changes the popup window that appears when the Fast Selection Task Bar button is pressed The changed window should be the same size as the Fast Selection window window No 4 We have already finished introducing the function key which has controlled the window have now let us make an example which control the window 1 Create a new project and save it 2 Create Fast Select Window 4 Common Window 6 Basic Window 11 Basic Window 12 the Basic Window 13 Basic Window 14 separately Window 12 sizes same as Window 4 here 100 350 Window 14 want smaller than Base Window size 14 here 640 480 3 Put 3 function keys on Window 4 namely 2 Change Window the function key is differentiated and can be switched over to Window 10 and Window 11 the function key of one JOG FS Window can switch over to Window 12 As the picture shows Bude Hindou 11 Toe Hindou 16 4 Put a text object at Window 6 show the text as Common Window 6 5 The Window 10 put one text object show text as Basic window 10 and two function key one of Return to Previous the other one for Popup Window the secon
156. r use the button to switch over from Window 10 to Window 11 in the Fast Select Window will return to Window 10 the ones that push Return in Window 10 will return to Window 11 12 Push Popup Window in Window 10 will spring Window 14 You can operate to the thing that it moves minimizes closes etc EasyView Basic Window 10 Po ue Window 14 Common Window 6 fae 2 11 Base Window 13 Choose Fast Window 2 in Fast Select Window will switch over to the 2nd Fast select window Basic Window 10 Popup Mindow 14 Common Window 6 Mindou 1 Mindou 2 14 Push Common window 2 or 1 can switch over and show the Common Window EaryView Basic Window 10 Common Window 13 Popup Window 14 Fast Window 1 Common Window 1 Common Window 2 6 7 9 Character Codes and Creating a Keypad ENT B5 CLR ESC ASCII Character a Hard copy A keypad is composed of a variety of function keys with different ASCII codes 0 1 2 and a b C and special keys ENT Enter BS Backspace CLR Clear and ESC Escape Since any character can be assigned to a function key specialized keypads can be made for any application Keypads are used with the Numeric and ASCII Input Parts to change their values cosa CCAR Ca TERR m prpep vr TERE cae Pe Pos SN ae How to create a typical Numeric keypad 1 By creating one function key then duplicating it changing its characte
157. rect Window places a defined child window area over the current window Usually Window frame as called by a PLC data register There is no limitation to the maximum Indirect their size is smaller than a full window The Windows are then displayed in the Indirect Windows on each screen However at run time only 6 windows at the most can be displayed simultaneously on each screen Set Read Address to 0 to close the window EasyView PITTI TA mpra pea z Window 10 Popup Window 20 rt M ey rer f f I I Denm thi EasyView Tuv ics boca Window 10 te ere Popup Window 2l e D188 t a Easy View N D166 26 D166 71 D166 6 Easy Vieu Procedure to place an Indirect Window 1 Click the Indirect Window Tool 2 Fill in General Tab Items Create Indirect Window Object General Description Head address Device type Lw v Device address 0 BIN v No of wards 1 Read address Word in the PLC that determines which window is displayed in the Indirect Window area When change the value of the register the designated window pops up For example if the value is 20 window number 20 pops up When the value is 0 pop up window is closed 3 Click OK to position the Indirect Window and resize it The display area of the popup window is restricted by the size of the indirect window The popup window
158. red Example Create an Alarm Bar Create a new project Set scroll speed from Edit System parameters General Add an Alarm Bar object on window10 and set the Display line and Char Length 2 and 40 respectively Click Alarm Display icon and enter the list Add two alarm information as below Alarm Scan Object Address Alarm Content 0 LBO On LBO ON Please Check Ll LEBI On LB1 ON Please Check Add two switches to control the ON and OFF of LBO and LB1 respectively Save Compile Online Offline simulation or Download the result as follows EasyView Please check LBO ON Easy View The state of ON or OFF of LBO and LB1 directly triggers the alarm message display of an Alarm Bar 6 22 Recipe Transfer Object RP Recipe Transfer Object can transmit the data from the prescription card of the touch sensitive screen to PLC can transmit from PLC to the touch sensitive screen Ask to consult chapter 8 in detailed content 6 23 Data Transfer DF This part is used to periodically transfer data from PLC to HMI or HMI to PLC Data Transfer functions are always active no matter what screen is being displayed Data may be single or multiple bit or word data The main function is to speed up the update rate of the screens Procedure to create a Data Transfer function 1 Click Data Transfer Tool to pop up the Data Transfer summary screen Data Transfer Object Source Des
159. rval selection is the frequency rate 0 0 to 25 5 seconds at which the block transfer is repeated An Interval of 0 0 transfers the data once at power up Click OK to return to Data Transfer summary dialog 3 Click Close in the Data Transfer Object dialog when all desired Data Transfer functions have been programmed When there is a lot of Trend display in a project its data amount is bigger the speed may be relatively slow if use Data Transfer Object can accelerate the speed that the data upgrade greatly So long as all set the addresses which read the data of these Trend displays as the continuous one use a all right once of Data Transfer Object to read the datum that reaches 16 words Word from PLC most can guarantee the continuity of Trend display in this way will not influence the renewal speed of the touch sensitive screen The following form shows for 3 Trend displays Object Device Type Begin address Data amount Time of taking a Word sample second The touch sensitive screen divides into 3 times and reads materials that DMO touched DMS it takes 3 seconds altogether When use Data Transfer Object the following form shows Object Device Type Begin address Data amount Time of taking a Word sample second Transfer Object DM gt LW oo Sa 1 50 100ms It only needs to read data once altogether Its time taken of communication is short Achieve the speed of communication and purpose to accelerate renewal spe
160. s 11 781 ms Found a CF card Compact Flash slot Put dipswitch 2 of the 12 781 ms Touch inside green rectangle um 13 782 ms to download project from CF card unit in the ON position and the others are all off Then push reset button The unit comes up in RDS mode and a green CF card button appears Click the green button and then start to OVANS ii 913531 ms The file size is 249201 bytes download After download the mode automatically switches to Application 913532 mode ti ILa msjy Erase Image Table OK 6914509 m s Erase Image OK 54 217799 m sj Write Flash 5057640 Completed ms Write Flash 5060 cid C m E IC 17334 ms rise Flash 5065524 om ted 405 wah cite BaoxE om 101fe00 EasyBuilder 500 User s Manual The CF slot of MT500 may not detect all brands of CF cards San Disk and PQP are suggested 3 Samisk 27 The CF memory card may be formatted as FAT16 or FAT32 3 3 Uploading We can upload the project from HMI to PC and then On line Simulation in the computer and download project enter other HMI to operate The upload file must be eob which is not allowed to compile on EB500 Uploading isn t reached in EB500 Upload the project through EasyManager Upload Open EasyManager set up the corresponding parameters The pop up dialog shows as follows TacyManaper Lookin 9 d om E a eob CM 1 114700 bps Project Downloadftpload bd template520p eob Complete Downloa
161. s recipe data each press to reach the purpose of looking up forward Set Word Ohject s Attributes General Shape Write address Device type Device address 9000 BIN v Attribute set stile Sub value TOCG b De ie Botomiint 0 We set look up backward as a multi state switch object In the same theory every time when you press this object system adds 5 from the value of LW9000 Because each set of recipe data includes 5 words RWIO displays the previous recipe data each press to reach the purpose of looking backward Here the upper limit is 45 10 sets of recipe Set Word Ohject s Attributes General Shape Write address Device type Device address 9000 wt Attribute set style Add valve JOG b lc vie Upper Create a Numeric Data object to display the current recipe data Numeric Data Objects Attributes General Numeric Font Description Eead address Device type Device address No of wor i However how do we know which set of recipe data is currently displayed How to control the value of LWO Here we create two more multi state switch objects one is subtraction and another 1s addition which display as follows Set Word Ohject s Attributes Set Word Ohject s Attributes General Shape General Shape Write address Write address Device type Device address EE Device type Device address n o o o BIN x BIN T Aux fees Attribute Attribute
162. s way LWO reads LW3 is the materials sources of 4 channel It is LW10 to look through page control can be used for looking over the historical materials Retentive control LBO can stop reading the materials of the trajectory The color of setting up 4 trajectories sequentially is red green purple blue minimums are all 0 the maximum is 500 1000 1500 respectively 2000 Add 2 scale components and 5 vertical lines as drawn LasyBuilder OPrj Window 10 Initial Screen EB fle Cot wee Option Dens Parts Liay Took Windies Hals Cah tha aTr ws X E ee EH alm A Aaa amp 100 Language Th V Ll H p p i ia 01 2 3 45 amp 7 8 5 1001 12 13 14 15 16 17 18 H 20 21 22 23 24 25 25 27 20 29 W 31 Sisir 0 3 P ast elector E y 7 6 Low ene 3 h iva krss ID XL wn bortoes Larger LI li CI fr i lil A tu EI LY 4s gi e m S M zi S3 3 Ji x Add 4 Set Word objects control LWO LW1 LW2 separately LW3 the establishment of these 4 components is totally the same among them LWO is set up as follows Create Set Word Object General Shape Label Description Write address Device type Device address Attribute Set style Periodical bounce Inc value Upper limit 500 Break time 0 1 second And then add increase and reduction that 2 Set Word objects controlled LW 10 in order to control and look through the page forward or backward
163. t lie in systematic parameter in database DataBase Start Address acquiescence is 0 Store in the information in Recipe Card including Eventlog manages information and time lands information In Eventlog manage information is it appoint address as start address store data size 30 words to store Eventlog information is thereafter followed closely each size of Eventlog information 1s the same is 20 words how to calculate that Eventlog information stores the size for example In System Parameter Hardware Eventlog database 1s chosen to be stored Database start address is 100 the following picture shows system Parameter Setting PLC General Indicator Security Editor Hardware Aum LED TFT PCD value Low we Display mode Landscape Recipe Eventlog database DataBase start address system parameter The system will begin to keep a storage area and use and store Eventlog database from RW100 in Recipe Card automatically can store Eventlog manages information and the following picture of 200 pieces of Eventlog information show RW170 The third Eventlog information RW4090 The 199th Eventlog information RW4110 The 200th Eventlog information The size of storage area kept 1s 200 20 30 4030 word the storage area for can t write area into any write into movement can t cause anticipated result as to user DataBase start address the user can set up at will but should pay attention to
164. t6 01 Nemericiat WENGE 2 Ott AdIDOUTO 01 Alarmfispla WGP Oii 7 Adj DOD 8 01 Set verd pe obti Sdpnat 01 Sefiend W 0020 Ob 005 Ad 00010 03 Move indicates window No 0020 object No 005 start address and length 00010 03 Move indicates Object name Double clicking the highlighted data turns the display to the window on which the object 1s The object is encompassed by white dotted line In this way any address of the object can be found Similarly select Part and choose the type you are looking for Click Search and the display shows as below PLE Lys a Pad Shape Search Copy We clipboard Total 14 objects Meg th Ob Shape wq Tp Ob OO Shape WIDOT Ob 007 Shape e001 ty Obie Shape WTO v Ob Shape ADDTT Ob D 09 Shape Vp t J buto Shape Win 2 dbi Shape rA 49 Cap 8 Shape 0049 Ob OOF Shape woog Obim Shape Pf D da Od H5 haji e ri mere m f i Double clicking the highlighted data turns the display to the window on which the object is and shows it Click on Copy to clipboard Object searching for now is duplicated to clipboard In this way you can clip and paste in any place 2 PLC Monitor Select PLC Monitor and the following dialog pops up EasyBuilder 500 User s Manual IUE m All current operating windows and the content are displayed by Fead PLE Black lninrmaltiam E AamScan amp Eventi eg rindew UJ B Trenditieplay amp DkataTranstespendin
165. tach Lib Delete Shape Can choose this Shape Library first when need to use this Shape then choose this Shape directly In Option Window Property use Function key it make by Shape Library it select the following picture shows Window Property Grideolor A Display Object ID Jump to application mode when download done Automatically save and compile when downloading or simulating If has not selected this function while making the picture pursueing to be drawn and storing to Shape Library Shape will be combined for the coordinate of the picture for the coordinate of selecting the picture at present tye Eary falder EE ez LEE m Dil chal Serera EB E Edt Yew pha Draw pet Like Took Wunlew li Bate we f x uua BEB Dw AAS I00 9 amp 6 Language t Hee e Boo Lis Wi 4A 34 5 b F B 9 WW 1 13 14 14 16 17 1H 18 Z1 ZZ Z3 24 5 Zb 2f Z8 29 W 31 siae U OY E i d Fet Seketon amp amp Comma Window 11 12 Al uma jen E JR i 1 BININU Uie am EE dinh ha Has del gx iE hi hi gx d um Dou on us ur dedu de gd dod d ies ed Be i fae ia Inet ena ose Ree MITSUBISHI Fit PR Shape Library Shape library button vi State 2 v Lej 1 2 L8 4 Ls Le JC J e L9 oaos 14 15 16 17 B _ 40 Untitled 41 Untitled 4 Untitled 43 Untitled LE EL dl 44 Untitled 45 Untitled 4
166. te position and label Attribute see the table below 3 Go to Shape Tab Select Shape or Bitmap to move and display states 4 Go to Label Tab Fill in fields to denote states if desired 5 Click OK to place the Moving Shape on the window x 1 Yz0 and then position and resize it Attribute Functions Up to 32 different states can be assigned to the Moving Shape Part The Read address should be 0 when the state 1s set to 1 or the object 1sn t displayed The corresponding address of Read address from 0 31 is from 1 32 Position is controlled by the Read Address Device as shown in the table below X for horizontal axis Y for vertical axis Read Address Shape or Bitmap State Shape or Bitmap State Shape or Bitmap State When scaling 1s used scaling is performed as follows Display value reading value Input min Input max Input min Scaling max Scaling min When reverse scaling is used scaling is performed as follows Display value Input max reading value Input max Input min Scaling max Scaling min Possible selections Create Moving Shape Object Ss General Shape Label Description Read address Device type Liv ww Device address 0 BIN v Attribute Style X axis only Ma of states Y avis only AMONT aW Input low axis w scaling Y axis wi scaling A ass wi reverse scaling Y axis wi reverse scaling Style Functions X axis only The M
167. the LW data will reset to 0 9000 9999 are reserved for system RWI Index to Recipe Word Please see ch8 RW Recipe Word After the HMI power off backup by battery 60000 65530 are reserved for system Ms RW Recipe Word located in the Master HMI Slave HMI use Ms RW to access Master HMI RW data Ms LW Local Word located in the Master HMI Slave HMI use Ms LW to access Master HMI LW data 4 Double Words address type Double words address has 2 types ddd and hhh In EasyBuilder No of words select 2 ddd address 1n decimal format hhh address in hexadecimal format EasyBuilder 500 User s Manual 3 5 EasyBuilder interface Click EasyManager s EasyBuilder button or directly select Start All Programs Easybuilder EasyBuilder500 in the menu bar If it s the first time running EasyBuilder or a last blank project was opened on last time log in the following popup dialog appears EasyBuilder Welcome ta EasyBuilder 500 Please select your model Nis Model URS TUR SEES UE LU E 1 hc Display made Landscape v Language Single Byte v Select the type of display and then click OK to enter EB500 screen editor window Or enter EB500 to open the latest opened project Select File New to create a new project The pop up dialog appears as below Select the appropriate type of display from the drop down box and then click OK to enter EB500 screen editor window EasyBuilder mE
168. the download format PLCAddressView Various kinds of brand PLC address types and ranges table The edition and relevant latest information explaining EasyBuilder 500 User s Manual 1 2 System Connections Typical connection for MT510 and MT5068 series reset contrast DIP Switch EESTI Ue l as DENIERS winter TERE I compuler To PLC RS 485 a Ee EasyBuilder 500 User s Manual Typical connection for MT506 series resel contrast NI5 PC cable line 12345 12345 EEEF Fao To PLC Rs 485 To PLC RS 232 computer PC RS 232 port of the HMI generally connects to the PC Since the PC RS 232 and PLC RS 485 share the same connector it s recommend to use MT5 PC cable provided which splits the port into two separate connectors to ease the program and test process Connect either the PLC RS 485 or PLC RS 232 port of the HMI to the PLC Check the PLC connection mode in the back of this manual to assure proper port connections At the same time be sure that all DIP switches are set to the OFF position EasyBuilder 500 User s Manual Chapter 2 Creating a Simplest Project Easy to use is the strongest advantage of EB500 software Through an example of project with a switch control object we explain how to create a simple project from EB500 Other project making is basically the similar procedure to this example 2 1 First Step First of all let us creat
169. the scale Range from is 1 to 255 4 Fill in Style Tab 5 Fill in Profile tab to adjust size EasyBuilder 500 User s Manual 6 Click OK and place the object myil a IET IF iki 10 ils wa TE k d See Cee Dem Cas idea fee Hd Pei Cre tee op ATE A SY eee EU pee seus t is 5 of gig E Ei F34 amp amp P B HW Nifi wise cr ARENA OO imd Ec M i E tei Slee Err rana em LODFT OU d4 ESNEUGUCD IDe Bur ckTEREHd8s 5 id 0 m Cox Doc atea J X Jk SE aes e uk i E t S BAIEF14 4 E 5 wii RETR IS RNP AMR a he Sa ML MMM es e L8 ic ra k EJ zl EBSEUGC D S IDBe Bur ckTERBHd8s 5d 0 The operation shows EasyView FEIE ASS eee ee EasyBuilder 500 User s Manual 3 5 7 Menu Parts The further details are discussed 1n Ch 6 3 5 8 Menu Library Please refer to Shape Library Bitmap Library and Group Library in Ch 5 3 5 9 Menu Tools jee Window Help There are five functions in Tools menu please refer to Ch 12 Compile On line Simulation Off line Simulation Download 3 5 10 Menu Window IGEN HEF Please refer to Ch4 Op en Window Cascade Tile w 1 EBPrjl Window 10 Initial Screen 3 5 11 Menu Help Abant EasvBuilder 1 Select Help Topics and the following dialog box appears Li MI EE LIT Ni ERI index f i Tope fus Fark less kie cd hee ec ou e iora lor
170. time the new events are displayed on the topmost line and previous ones are below it If the value is N the No N information will be displayed in the first line No of words The Read address and write address are fixed at 1 for this part Write Address A word that receives the write value specified in the Event Log s trigger event 3 Fill in Event Display Tab Items Display line Specify the window height in lines of Font 16 text per line Character length Specify the number of words displayed on each line Text space The number of pixels above and below messages Acknowledge style Click is touch once Double click is touch twice quickly Color Colors of message text for different states Acknowledge the color after the event information is confirmed Return to normal the color of the time when the event returned to a non triggered state Select box the color of a dashed line that highlights a selected message Create Event Display Object General Event Display Display in Character length Text space Acknowledge style Calor AB Acknowledge nmm Return to normal Select box Terni tA ADA Sequence no L Event trigger time Acknowledge time Return to normal time C Extended time fornat D H M Short time fornat H M C Event tigger date M D Extended date format M D Format The information displayed before the message such as Sequence No Event Trig
171. tination Kode Interval No of bit ED LBI0 Bit 0 0s 0 Click on the Add button to create a new Data Transfer function or click on the Setting icon to modify an existing Data Transfer function If you click on the Delete button the current highlighted function is deleted 2 Assign options in the Data Transfer Object dialog box Data Transfer Object Description Source address Device type LB 4 Device address 0 Destination address Device type LB J Device address 10 Attribute Address mode Bit Interval 0 0 second No of bits 0 Description A reference name that you assign to the Data Transfer not displayed Source address The starting address of the bit or word to transfer Destination address The starting address of the bit or word that receives the data Attribute Address mode Set Address mode to transfer Bit or Word data Select Bit data the attribute dialog shows as above Select Word data the attribute dialog shows as below Data Transfer Object Description Source address Device type LY v Device address 0 No of words m v Destination address Device type LY l v Device address 10 Attribute Address mode Woru D Interval 0 0 second v Number of Bits The number of consecutive bits 1s to be transferred Interval The Inte
172. ting with DM10 four initial data registers should put one PLC and control the component at the window of the touch sensitive screen first choose the type to control for PLC in common use read the address as DMIO 2 next should confirm the skew amount of the size and address of one of operating data it 1s 30 to give the establishing value of DM11 show that it is 30 words to transmit the size of one of the data It is 86 to give the establishing value of DMI2 it is DM100 of PLC that it is initial to show the source operated 144 86 It is 200 to give the establishing value of DM13 show that the goal address is RW200 z 04200 3 needs establishing and transmitting the type code according to the direction of data transmission finally carry out the transmission course it is to give the establishing value of DM10 show and carry out data transmission in data one of PLC that will establish the start address that reaches the touch sensitive screen which establishes the start address to fill a prescription in the memory data one If it is 3 to establish DM10 value it is 1n opposite direction to transmit As a same reason the transmission of two kinds of other directions is operated the samly just touch and reject the square data memory to turn into local data register LW 6 27 System Message M M oes system messages for different languages When the display cannot access the PLC PLC no response is displayed When the repl
173. tion button or reset the display to application mode the project is operated on the display 2 Downloading through EB500 Open the epj file name of the project on EB500 or the current editing file select Save in the Edit menu and then select Compile in the Tools menu After compiling close the compiling dialog In Tools menu select Download or press icon The pop up dialog appears as below E E C Nacuments and Settings poy X Downloading image table Mission complete OK Click OK when finish Click on Jump To Application button or reset the display to application mode the project is operated on the display 3 Downloading through Compact Flash memory for E series MT500 E series support the function of downloading through Compact Flash memory EasyBuilder 500 User s Manual After editing compile and save Io Frajzrinamr UC ejec Sr eT di pj Compas Wir namo DU epjecRAE Ue RSCHETTUSBEL Lr aki Click ImagCF icon from the programs list CER La a EFasyBuilder 500 Rasyblanager PLCAddreszV iew ReleaseNote pdf Reserved Word bit pdf Click 4 icon and open eob extension compiled from stepl ImageCF exe program combines eob file and related bin file to a Q Fro ject EES00V250 DEMO MTSO0E4 ImageCF bin Please don t use other name C EBSOO ImageCF bin on this file Copy ImageCF bin to the root folder of CF card Insert the CompactFlash card into the unit
174. to see how a window s background color affects the way a shape appears The background color of the shape object in the library does not follow the shape when it is placed on the window Attach an existing library to the current project Attach a new blank library to the current project Remove a library from the current project Delete all the shapes from the selected cell Place the shape on the current window as a group of draw objects Note After create the new shape library or new shapes have to save project Otherwise the library or shapes will lost 5 6 Selecting a Bitmap There are two methods to use Bitmap One 1s static Bitmap another way is display different object states The static Bitmap object methods please refer Ch 3 5 6 Selecting a shape for object 1 Click on the Shape tab 2 Select Use Bitmap 3 Click Bitmap Library Create Hit Lamp Object General Shape Label shape Use shape Bitmap Lo S The Bitmap browser will pop up The Bitmap graphics are stored in a specified Bitmap library blIb file Each project 1s able to include a maximum of 10 Bitmap libraries By calling up different Bitmap libraries a useful Bitmap library for almost any application can be found Users can also build up their own Bitmap libraries Bitmap Library E v state 0 v me mmmm Bitmap name f Total states i e 2 2 Compressed d d L Image size 6320 6400 313
175. ts to the address with data 51 The table shows as below LAW S000 50 RWIC LW 3000 51 0 5 3 5 Basing on the concept above here we take an example 3 RWIS OXU777 a ieee 5 We create a project and select PLC type as MODBUS RTU We upload 5 consecutive numbers starting at address 200 from device type as 4x to RW300 address of recipe memory and the consequence explains as below Before Upload After Upload AVE D RE GH TT We create a new project and choose PLC type as MODBUS RTU system Parameter Setting PLC type HMI model PLC LF port Data bits stop bits Parameter l U Parameter 3 U Parameter 5 U HMI station no Multiple HMI MTSIOTMTSOST 640 x 480 Feats Bits Bit ceo il Baud rate Parity Turn around delay 19200 Even Parameter d Parameter 6 PLC station nno HHMI HMI link speed Connect IF Serial Local IF address server IP address subnetwork mask Default route IP address PLC tme out constant sec Apply First of all we add a Recipe Transfer object with device type 4x Device address 200 No of words 5 Direction is Save and content as Upload Create Recipe Transfer Object Create Recipe Transfer Object General Shape Write address Device type Device address Attribute Direction Attribute Color MN Hi
176. ttributes display as below Create Function Key Object General Shape ENT BS CLE ESC A8CIT Hard copy Attributes Change window CO Return to previous O Change common window Window no Popup window O Close window O JOG FZ window O Window bar CO Minimize window O Mesage boad Set operstion mode Attributes Create Function Key Object X General Shape Attribute Color a Font 24 Bold Italic Switch over it to window 11 Use label Use Label Library Tracking Label Library Duplicate this label to other states Save compile and Off line simulation Window 160 current security level Easy Uieu When we press function key we are not allowed to switch to window 11 The reason is because the current security level is O but the security level of window 11 is 1 Lower security level can t access to higher security level We are allowed to enter higher security level by inputting password System register LW9040 LW9041 are for setting password Add another Numeric Data object on window 10 Create Numeric Input Extend Object General Numeric Shape Font Liescriptian Read address Device type LW s Device address 9040 BIN No of words 2 Trigger address Device type LB s Device address 9000 Note The system is kept register LW9040 LW9041 the introduction password number is double word Add
177. umbers are encoded by bit weight 15 1413 12 0 109 8 7 6 54 3 2 1 0 BCD binary coded decimal format Decimal numbers are encoded by bit weight per 4 bit nibble 5 141 13 12 1 10 9 18 7 6 5 4 3 2 1 0 0 3 2 1 10 10 10 10 Examples The Read address raw data is 10010100 7 6 5 4 3 2 1 0 1 2 0 2 0 2 1 2 0 2 1 2 0 2 0 2 128 16 4 148 DEC The Read address raw data 1001 0100 910 4 10 94 BCD DEC 6 3 Set Bit HAA The Set Bit Part defines a touch area that when activated changes the ON or OFF state of a specified bit Procedure to place a Set Bit 1 Click Set Bit icon l 2 Fill in General Tab Create Set Bit Object General Shape Label Description write address Device type LB Attribute Style ON Set OFF at window close Set ON at window maximized Set OFF at window maximized Set ON at window minimized Set OFF at window minimized Set ON at backlight off Set OFF at backlight off Set ON at enter success Set OFF at enter success Set ON at backlight an Device address E Description A reference name that you assign to the Set Bit Part not displayed Write Address Address of PLC that is acted on by the Set Bit action Style Consult the attached list of this festival 3 Go to Shape Tab Select Shape or Bitmap to display graphics that represent the touch area 4 Go to Label Tab Fill in fie
178. ust be unanimous and totally overlap together Add 4 Numeric Data objects show LWO separately LW1 the number value of LW2 and LW3 Add 4 Set Word object many state establish component part of LWO LWI the data of LW2 and LW3 carry on the cycle circulation change Its corresponding minimum is all 0 the maximum is 500 1000 respectively 1500 2000 The progressivelying increase value is 10 frequency is 0 5 seconds Set Word Object s Attributes General Shape Label Profile Description Write address Device type Li Device address 0 BIN Attribute Set style Periodical bounce Inc value 5 Upper lirit anu Break time 0 6 second Result set up finally La volun sr ERTI indices 10 Tithe TI 1 EB File Cat Vew Oh Dee Parts Ubay Took Window Help DB m HT A4 J 3 Hee EHE ugung AANA HE a Language M 0 i 3446 amp 7 8 98 Wi i I3 14 1h 16 17 18 18 20 21 27 23 24 25 Ph 277 28 2a 30 SI Sime w k 4 F Sem Mic b Corm rere gus inum So ee IE UL Daca La HD Owl ND Lin D p D WW Sw Or Wo Sw WI Eu MIO i n L EE Set a E a a a ee uH lt NE oF k BR 5h oo a e amp BS B Result operated finally E i e i FE EX 1 a 4 a 4 4 i I i 3 ee oe 4 4 i j aae ar dda i Ei es ee haul
179. windows Password 8912901 startup window no 10 vi Back light saver Cursor color e 3 Buzzer Enable Common window Popup window Attribute Below base seen 4 Extra no of event LR RIC source Local Word Print 4 Printer None k Print sequence number Print time tag Extended time format D H M Print date tag Extended date foxmat Y MDS Error detection show message Message board window No iD 10 1999 2 Click on the General Tab Select the different drop downs to determine how the task bar will appear Then in the Window menu Select Open Window Open Window No Window name Fast Selection 100 446 Common Window 640 400 New Window Initial Screen 640 400 NumkKeypad1 235 300 Numkeypad 235 300 Task Button Press Task button then press Window or Screen buttons to customize how the Fast select button or Window bar button will look Window Setting Name TaskBar O Window no e Start Pos X c 0 Size Style Tracking Monopoly Clipping Coherence 3 Fill in the blanks of the Fast Window and Window Selection dialog The Fast Window dialog has the settings for the button that controls the bar where window icons are displayed The Window Attribute dialog has the settings for the button that controls the popup Fast Window Window Athibute General Shspe Label Attribute Style Set Fast or Slow t
180. y Lib ieee Tools shape Bitmap Group P Label 2 Setting the Tag Library Tag Library Counter value Detecting device Number value sho miai rotation Start Stop Timer value WORD BIT RD WORD address address address address address address address address Delete Modify Export Export CSV Import CSV Add Adding a new address tag to the tag library Delete Deleting an existing address tag in the tag library Modify Modifying the contents of an existing address tag in the tag library Exit Exit the tag library dialog After pressing Add or Modify button a dialog appears shown as below Tag name NONAME Address type Bit v Device type B d Address 0 Tag Name English or Chinese character can be used to identify an available register or a PLC Addresses Maximum length of an English tag name s characters is 10 and maximum length of a Chinese tag name s characters in is 5 Address Type An address type is Bit or Word Device Type Selecting a device type to set relative device type or address Address Defining an address After pressing OK button a new address tag 1s added into the tag library 3 Usages of the tag identifications Objects possessing an address attribute can use the tag library in EB500 Now usages of the tag li
181. y message from PLC is different than expected PLC response error is displayed When the system runs out of memory or some other fatal error occurs System severe error is displayed System Message Message 0 PESTES TIES Message 1 PLC response error Message 2 System severe error Procedure to modify system messages 1 Click System Message icon to pop up the system message dialog box 2 Fill in appropriate text for the content of each message 3 Press OK to finish the modification There are these 3 systematic information that can generally let users revise For furhter details please refer to appendix me about other systematic information system information 6 28 Object Superpose If superpose a lot of components together a lot of special functions will emerge MT500 can support the superposing of a lot of objects when touch and accuse of these objects the procedure will carry out corresponding operation with the different levels order of each object touched and accused of at first in object of the upper strata the most then the second layers of object For example If 6 Set Bit Toggle Switch objects are superposed together whether control YO upper strata most reach Y5 lower floor most then when touch and accuse of these objects MT500 is the executive program in the order of the following separately First layer Carry out the order of YO at first The second layer Carry out the order of Y1 The third

Download Pdf Manuals

image

Related Search

Related Contents

  CFSL 6209 Informazioni in materia di sicurezza sul lavoro e tutela  nRF51822_422_DK User Guide.fm  ETS-T40 User Manual  Windows  guide de l`utilisateur user`s guide guìa del usuario anwender  ML590, ML591 - LPT Home Page - HP LaserJet and Lexmark Parts  < SYSTEM BUS v  Education par la Technologie  収録システム 取扱説明書  