1. no 2 just enter 3 2 2013019019 17 16 Thu Check the relay status in ON or OFF Master relay lt ON gt Mode 2013 10 10 16 10 Thu 7 Check Signal Strength CSQ lt 28 gt 2013 10 10 16 11 Thu Setting the year month day hours 12 YYYYMMDDHHMMxX Time change OK minutes week 2013 10 10 16 05 Thu Delete Admin Number Delete 1st admin 3 1 Delete 2nd admin 3 2 Delete 3rd admin 3 3 Delete 4th admin 3 4 Delete 5th admin 3 5 The unit will return Master relay lt ON gt if the relay is on The unit will return Master relay lt OFF gt if the relay is off You must confirm the signal strength at site before you install the unit If the signal too weak the unit will not function properly CSQ 5 12 Signal too weak system not function CSQ 13 24 Signal Good System function well CSQ 25 32 Signal Excellent System working well YYYY 4 digit for Year MM 2 digit for Month DD 2 digit for Date HH 2 digit for Hour MM 2 digit for Minutes X 1 7 Day of the Week Example set as 12 2013101016054 which means 2013 10 10 16 05 Thu If reprogram the date it will take the last as the accurate date The date have to be correct if setting 2014 2 29 or 2013 11 31 this is the incorrect date which is not occur the system will verify the date time day if correct the date have to be after year 2013 WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual
2. order is accepted and confirmed O2 Call 1760 gt Send you will hear order is accepted and confirmed T Mobile Call 222 and follow instructions WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 me Orange Call 450 and follow instructions The SIM card is now ready to use We recommend that if you are using a pay as you go PAYG SIM card that you choose to automatically Top Up when the cards credit falls below a certain limit please contact your network provider or visit their website for more details Most but not a using post paid SIM cards will be de activated by the network if not used to make an outgoing voice call or send an SMS text message within a specific period To prevent this simply send the GSM Remote Control Switch a text command O PWH then 2 it will reply by text message do this once a month to keep the SIM card active Troubleshooting Red power LED not alight Blue network LED flashing every one second and not every 3 seconds am not receiving confirmation test messages when program the administrators number am not receiving any text messages when initially programming the unit The unit has been working for several months and has now stopped responding to calls and text commands When I call the unit to set administrator do not receive a confirmation text message Ensure that your DC power supply is connected cor
3. D WT 1674 Power Supply Remote Control Switch User Manual V1 1 aan The user also can download the FREE apps from Android and IOS stores as their easy monitoring and control tools Just one touch on the apps user smart phone will sent the SMS text commands to the unit The users don t need to remember the commands code SETTING UP AND PROGRAMMING Step 1 Easy Programming Open Mode Anybody can call to the unit to Switch OFF and Switch ON Open the Cover Insert the SIM card Plug the wire into the AC sources Plug the electrical appliances socket into the unit Call to Switch OFF Call to Switch ON gt es iS The GSM Power Supply Switch is factory pre wired Open the cover insert SIM Card into the unit plug the unit into a main AC power socket and then plug electrical appliances socket into the socket at the another end of the unit Now you are ready to control the electrical appliances by just a free telephone call to switch the device OFF and another to switch the device ON When first booting up the system you will see Green LED Lights inside the Enclosure and it should light up when the Network is applied to the unit The Green LED is the network Indicator and this will light up when attempting to log on to the network flash inconsistently until it locates the network The Status of the Relay will remain as ON until the unit receives a second Call to the Unit of which will now Latch the Relay Permanently OFF Bot
4. DIG 2 31 pm g 100 lt Messages WT 1674 Contact Administrator 1 18617185299 2 3 4 5 O Send You already finish the set up Now you can use your mobile phone call to the SIM Card number switch the device on permanently Another call to the SIM Card will switch the device off permanently If you do not required to go through details setting please process to STEP3 Final Installation and Wiring WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 EA Factory Reset in the Secure Mode When you active the safety features and if you required to change the administrator number in the future simply press the button FACTORY at the mother board until you hear the di This means the unit back to the factory default Press until you hear the di sound This means you already reset the unit to factory default Now you can start to call again to set the administrator This method is only allowed to set 1 administrator number If you wish to set more administrators please go to Step 3 Installation and set up WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 Bo Step 2 Advance Set Up First Step of programming you must enter the factory passwords of 1234 and go inside the programming mode You only can perform the next commands after enter into programming mode Change Password 3 Add telephone number into
5. OT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Wherever possible return only the PCB to Witura Service Centres DO NOT return the enclosure The WT 1673 is a product of Witura Technology Sdn Bhd And is manufactured by Shenzhen Witura Telecommunications Co Ltd WARNING For safety reasons only connect equipment with a telecommunications compliance label This includes customer equipment previously labelled permitted or certified WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 fa
6. V1 1 aan Schedule the ON OFF for the Master Relay Checking the schedule time for Master Relay ON OFF Delete the schedule time for the Master Relay ON OFF SMS Reply Message when the system ON OFF 13 N YYYYMMDDHHMM 15 N 21 N Master relay off time 2013 10 10 16 33 2013 10 10 16 31 Thu When the programmed time is reach the relay is either on or off all the admin will get the reply SMS as per below Since time is up Master relay lt OFF gt 2013 10 10 16 33 Thu Master relay on time Master relay off time 2013 10 10 16 33 2013 10 10 16 35 Thu Master relay on time Master relay off time 2013 10 14 11 08 Mon Message switch lt ON gt 2013 10 10 17 06 Thu N 0 Switch Off the Master Relay N 1 Switch On the Master Relay YYYY 4 digit for Year MM 2 digit for Month DD 2 digit for Date HH 2 digit for Hour MM 2 digit for Minutes Example set as 13 0 201310101633 which means 2013 10 10 16 33 to switch off the master relay If reprogram the date it will take the last as the correct date If you program the date that already past the system will alert you Checking the schedule time for Master Relay ON OFF when the time reach the system will operate and it will delete the schedule time automatically N 0 Delete schedule of Relay OFF Time N 1 Delete schedule of Relay ON Time N 0 means SMS Reply Message when the system OFF N 1 means SMS Reply Messa
7. __ AC DC ADAPTER MODEL H P HPT He aA OE OUTAT GC 20rd WAAR For indoor Uae Oriy MOR SAS WT 1674 Power Supply Remote Control Switch USER MANUAL WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 fu INTRODUCTION The Power Supply Remote Control Switch model has been specifically designed for the rental of washing machines or any rental of electrical appliances industry to allow the owner to have remote control over the appliances regardless of the location of the equipment In many examples the rental of the electrical appliances does not allow the owner to ensure that they are being honestly for the rental and is continued to be used even they did not pay for the rental The unit also designs for the rental of machines or construction equipment In many examples the remote location of the equipment does not allow the owner to ensure that they are being honestly informed when the equipment is actually off hire and is continued to be used after it has been claimed to be off hire The unit will look same as power supply with label as 9V inline power supply This is to prevent the user disconnect the GSM unit The unit with 1 independent 30A relay switches these can be programmed to switch off or on whenever the GSM Power Supply Remote Control Switch is called when end customer dishonest the rental The Power Supply Remote Control Switch will recognise an authorised telephone numbers cal
8. caller Factory Default as return SMS for the status after make the phone call If you decide not to allow the system to text you for any acknowledgement after you call to the unit You can switch OFF the text message Some Customer request this function because texts reply involved call cost N 1 means in security mode Only allow the number in the list can text to the unit to control the system N 0 means in open mode Anybody can call to the unit to control the system Please take note that the Privacy and Security before you decide to use the Open Mode Factory Default is N 1 for Security Mode N 1 means switch on the relay by SMS Message N 0 means switch off the relay by SMS Message WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 C Setting Time for the unit to SMS When sending the reminder to the Administrator for command of 9 01 the SIM Card balance Warn frequency 1 month 2013 10 10 17 18 Thu Step 3 Installation XX 00 Switch off the Time Reminder for SIM Card Balance XX 01 to 12 which means after setting this command the unit will start from the 1 of the following month to sent a SMS reminder for the SIM Card balance for every 1 month Please note that the phone SIM card balance 2013 10 10 00 00 Sun Insert the SIM card to access the SIM card carrier gently push the button adjacent to it insert the SIM card and carefully clo
9. eir website please refer to the instructions supplied with your SIM card During the registration procedure a confirmation code or text message is usually sent to the SIM cards telephone number to be able to read and react to the message you will need to insert the SIM card into an unlocked mobile phone After successfully registering the SIM card ensure there is sufficient credit on the card for programming confirmation texts to be sent from the GSM Remote Control Switch You MUST ensure that the PIN request is disabled from the SIM card before inserting it into the GSM Remote Control Switch If you do not disable the PIN request the GSM Remote Control Switch will not work If the PIN request is not disabled and the unit is switched on more than 3 times you will have to reset the PIN using the PUK code which will have to be obtained from the service provider To check the PIN request status of your SIM card place the card in an unlocked mobile phone switch the phone on If you are able to make calls without entering a PIN number the PIN request is disabled If a PIN number is requested refer to the instructions supplied with the SIM card and then look through the phones options for the disable PIN request and disable it You MUST disable any voicemail that is set up on the SIM card the codes shown below are for UK networks only please refer to your network operator if outside the UK Vodafone 1210 gt Send you will hear
10. ge when the system ON Factory Default as SMS Reply Message when the system ON If setting to not receive SMS Reply Message when the system OFF the unit will return a message indicate successful setting for the command and it will no longer sending SMS reply until the setting of SMS Reply Message when the system ON is done When the system having the temperature alert wireless alarm alert it will automatically sending the alert message to the Admin WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 go 13 To receive SMS Reply Message or not to receive SMS Replay Message when the system trigger by phone call Security mode Open Mode SMS Text Message to Switch On Off Relay 22 N 23 N 24 N After sending command 22 0 Status switch lt OFF gt 2013 10 10 17 10 Thu After sending command 22 1 Master relay lt OFF gt 2013 10 10 17 08 Thu When Setting as Security Mode 23 1 Mode switch lt ON gt 2013 10 10 17 13 Thu When Setting as Open Mode 23 0 Mode switch lt OFF gt 2013 10 10 17 13 Thu When Setting as 24 1 Master relay lt ON gt 2013 10 10 17 13 Thu When Setting as 24 0 Master relay lt OFF gt 2013 10 10 17 13 Thu N 1 means after make the phone call to the system it will return the SMS for the status to the caller N 0 means after make the phone call to the system it will not return the SMS for the Status to the
11. h Calls used to Latch the Relay either on or off are automatically disconnected once the relays are activated and never incur any Network Call Costs Beside calls to switch off or on the unit also can be permanently switch off and on by sending the unit a text message command Now you can download the apps either in Google Play or IOS apps stores for easy controlling and status monitoring WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 Bo Step 2 If you feel that open mode is not secure program your phone number into the unit Applied the KISS Principle keep it simple stupid If you feel that Open Mode is not secure You can program up to 5 phone numbers into the unit Only the person in the white list can switch OFF ON 1 Open the Cover Insert the SIM Card 2 Use your phone number call to the unit It will automatically register your number into the white list 3 Use your phone number call to switch off switch on The GSM Remote Control Switch is easy to setup and use Insert the SIM card simply use your mobile phone call to the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185299 your phone number 2 3 4 5 Call To The SIM Card No Of WT 1674 et Return Text Messages Administrator 1 18617185299 23 3s 4 5 eee
12. ling it and action the call without answering Therefore there is no call charges incurred when calling it One Call to the SIM Card Number will switch the device OFF permanently Another Call to the SIM Card will switch the device ON permanently The system also supply with timer function and auto trigger relay to switch off When the off hiring periods over the unit will automatically switch off the electrical appliances according to the schedule set inside the unit For example if the off hiring periods is 6 months the owner can set the time to switch off the equipment 6 months later and SMS text to the owner This function is important to use in the renting and leasing industry of electrical appliances washing machines coffee maker heavy vehicle and rental of site equipment to turn off the machines when off hire time completed The system also has another important function to reminder the owner to monitor the SIM Card expiry date User can set timer to remind the owner the SIM card expiry date The unit also can be instructed to trigger the relay in the specified times to keep the SIM Card alive and sent the SMS to the user to keep the SIM card active when expiry dates The system using CE and FCC approved industry internal power supply connected on board A backup lithium battery can power up at least 8 hours and will sent a power down or power restored alerts in the event of any circuits power failure WITURA TECHNOLOGY SDN BH
13. rectly positive to terminal 220v and negative to terminal N Verify 12 volts is present using a volt meter Ensure your SIM card has been activated and that the PIN request has been disabled If the unit is in a low signal strength area consider using an external GSM antenna or changing to another network provider Ensure your telephone number is in the Administrator list and that sending text messages to your number is enabled Ensure the unit is connected to the GSM network by observing the blue network LED it should be flashing once every 3 seconds see 2 above Ensure the SIM card has credit Most but not all PAY SIM cards will be de activated by the network if not used to make an outgoing voice call or send an SMS text message within a specific period To prevent this simply send a txt command 0 pw then 2 it will reply by text message do this once a month to keep the SIM card active Reset the unit to Factory Default and try again Sent 1672 commands to the unit WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 hs Warranty Witura Technology Sdn Bhd warrantees the WT 1673C GSM Remote Control Switch against defective parts and workmanship Witura Technology Sdn Bhd shall at its option repair or replace the defective equipment upon the return of such equipment to any Witura branch This warranty applies ONLY to defects in components and workman ship and N
14. se the carrier Connect the cable to terminals 220V amp N ensuring positive is connected to terminal 200V switch on the power supply the red power LED will light indicating power is present the blue network LED indicator will initially flash quickly once logged onto the network it will flash more slowly approximately one every 3 4 seconds It is recommended that the GSM Remote Control Switch be programmed to operate as required before final installation WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 to Connection Details If you are unsure how to connect the device you wish to control refer to a qualified person Example Connections For Washing Machines Wiring Diagram Washing Machine Internal Circuit Example Connection for the Electrical A liances and Electrical Products WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 ia Production Specifications Operation Voltage 12 volts DC Operating Current Maximum 500mA typically 55mA Relay Contacts 1 x Normally Open and Normally Closed Contacts maximum switching capacity 20 amps 230v ac per relay GSM Frequency MHz GSM 850 GSM 900 GSM 1800 GSM 1900 Physical Size 130 x 100 x 50mm CE FCG ETS Preparing the SIM card All new SIM cards have to be registered with the network provider before they can be used usually by calling the network provider or registering on th
15. the admin list Check phone number you program in the list R 0 1234 0 1234 new password For example if you need to change to the new PW of 1212 0 1234 1212 1 1 telephone number For example set Admin number 18617185300 into admin 2 1 2 18617185300 You get administrator privileges 2013 10 09 00 33 Wed New password lt 1212 gt 2013 10 10 16 07 Thu Administrator 1 15989427391 2 18617185300 2013 10 10 16 08 Thu Administrator 1 15989427391 2 18617185300 2013019019 16 09 Thu When you enter 0 1234 you enter into the programming mode You must perform the next command in 10 minutes If you did not do anything the system will exit from programming mode Maximum 4 digits of passwords If you decide to protect your privacy you can change the factory password to your new password Enter the factory password follow by your new password Set Admin Numbers number number number number number set 1st admin set 2nd admin set 3rd admin set 4th admin set 5th admin Only the number in the list can receive alarm texts message and active the relay output You can add up to 5 telephone number into the admin list WITURA TECHNOLOGY SDN BHD WT 1674 Power Supply Remote Control Switch User Manual V1 1 aan Delete the admin number in the list 3 N Administrator 1 15989427391 N Admin number 1 5 For example if you want to delete admin