Home

User Manual - Universal Fibre Optics

image

Contents

1. Notes Universal Fibre Optics D UNIVERSAL FIBRE OPTICS Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel 44 0 1890 883416 Fax 44 0 1890 883062 www fibreopticlighting com
2. The Aurora requires a 240VAC 50Hz supply and it MUST BE EARTHED The light source power supply units are provided with a cordset fitted with a standard 3 pin plug POSITIONING THE UNIT 1 emo WU O o he E Ze 16 A Dei PA Ah ie hh ANT les pe Le A A AS yy p eS d E 5 a w Standard horizontal mounting on shelf table i 7 misti SC d CO Fi Poi Ms L F EC lin d l LR ce mn li Cp A E E _ Se A EEE PR P TA PTT dd OL Vertical mounting i secured to wall Upside down mounting fixed to underside of shelf The light source can be fixed to a suitable surface or be used unfixed by utilizing the four rubber feet on base Note for most applications fixing is recommended The light source itself may be mounted in any other orientation than pointing the exhaust vent downwards The light source can be fixed to a suitable surface by using the two keyhole slots on the base of the unit Horizontal mounting can be achieved with the keyhole slots acing downwards i e screwed to the top of a flat surface or upwards i e screwed to the underside of a shelf etc Universal Fibre Optics D INSTALLATION GUIDE Continued Verify that the supporting structure can safely bear the weight of all installed units cables and any other equipment For horizontal mounting it is recommended that the lightsource is secured to a solid surface using 2 x M4 or M
3. lamp D 6 Connect the new lamp to the ceramic plug making sure that you use a lamp ofthe same specification as to that which was removed Also make sure not to touch the front of the lamp 7 Slide the lamp back into its holder 8 Close the lamp access hatch and secure with the retaining screw Note In the 100W version of the Aurora the lamp holder will only accept a 64637 GZ6 35 100W lamp 7 Aurora Light Source Range MAINTENANCE Continued FUSE REPLACEMENT 1 Unplug unit from electrical supply and allow to cool 2 The fuse holder A is located under the mains power input socket 3 Using a small screwdriver carefully insert it into the slot on the top of the fuse holder B and prise outwards 4 The fuse can now be unclipped from its holder and replaced A spare is provided inside the storage compartment at the rear of the holder 5 Slide the fuse holder back into its slot until it clicks into place 1 Unplug unit from electrical supply and allow to cool 2 Remove the single screw A which secures the unit s access hatch 3 Open the access hatch and you will see the colourwheel mounting rod is secured with two screws through a brass bush B 4 Remove the screws and carefully pull the rod towards the front of the light source Remove the colourwheel and rod from the light source eg 5 Close and secure the access hatch IMPORTANT A maintenance record table i
4. 5 screws or bolts and the keyhole slots This is particularly important if the lightsource location is not at ground floor level To mount the light source vertically first securely install 2 x M4 or M5 screws or bolts at the required distances so that they will line up with the keyhole slots The light source can then be mounted onto them and slid into position The bolts or screws MUST be fully tightened To mount the light source under a surface first securely install 2 x M4 or M5 screws or bolts at the required distances so that they will line up with the keyhole slots The light source can then be mounted onto them and slid into position The bolts or screws MUST be fully tightened CLEARANCE VENTILATION It is imperative that a gap of 200mm 8 or more is left around the unit This is to allow air to circulate and prevent overheating The location must have free ventilation 5 Aurora Light Source Range INSTALLATION GUIDE Continued CONNECTION There are 2 connections required the fibre port and the mains power supply On decorative models with a separate feed there is an additional mains power connector to power the colour twinkle wheel Connect and secure the fibre optic connector to the fibre port before connecting the electrical supply Never run the light source with the fibre connector unplugged Fibre connector y OPERATION Plug the light source unit into the electrical supply socket Switch on the power to the
5. A A ta SAVE THESE INSTRUCTIONS e Always disconnect the unit from the power supply before opening or attempting to perform any work on it e UNIT MAY GET HOT always allow unit to cool down before handling or moving it e Do not touch or attempt to remove the lamp while it is hot e Ensure that the power supply is correct for the unit before powering it up e Always ensure that the unit is properly EARTHED e Do not expose the unit to rain or moisture e Keep away from all combustible materials e Never attempt to tamper with the wiring or other internal components e Keep the unit away from gas oil and any other flammable or explosive materials Universal Fibre Optics 2 LIGHT SOURCE LAYOUT Description Lamp Colourwheel access hatch Fibre port Cooling fan Power LED Power input connector amp fuse holder Varies depending on model White light models no function Decorative models with separate feeds secondary power input Decorative models with switch switch to control colourwheel Optional dimmer control OG Aurora Light Source Range INSTALLATION GUIDE In order for the Aurora light source to function safely and efficiently it must be installed according to this user manual Please read all sections thoroughly before switching on the light source POWER SUPPLY REQUIREMENTS Before plugging in the unit please make sure that the supply is correct Failure to do so could cause the unit to malfunction
6. Farma uit PRE FIADE APP a LA ARPA AAN kel Ek Light Source User Guide Aurora Light Source Range Models covered by this manual UFO 35 42 50 75 100 G UFO 35 42 50 75 100 P UFO 35 42 50 75 100 GC UFO 35 42 50 75 100 PC UFO 35 42 50 75 100 GCF UFO 35 42 50 75 100 PCF UFO 35 42 50 75 100 GS UFO 35 42 50 75 100 PS including variations with dimmer and wheel control Please read this manual fully before installing operating or performing maintenance on the light source unit Universal Fibre Optics Home Place Coldstream TD12 4DT United Kingdom Tel 44 0 1890 883416 Fax 44 0 1890 883062 www fibreopticlighting com Issue 2 Revised 10092013 INTRODUCTION Thank you for purchasing this UFO Light source Please read these instructions fully before connecting your unit to the electrical supply and keep them for future reference The UFO Aurora range of light sources are compact tungsten halogen light source s suitable for use with polymer fibre The Aurora is suitable ONLY for use in countries with 240VAC 50Hz mains electrical supplies The Aurora features low noise and heat output an optional factory installed 6 colour colourwheel or decorative twinkle wheel and is available with a choice of five lamp sizes 35W 42W 50W 75W and 100W IMPORTANT THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PROD
7. UCT AND THE HAZARDS INVOLVED Do not operate without complete lamp enclosure in place or if lens is damaged KEEP HARNESS IN PLACE WHEN IN OPERATION CAUTION Hot surface Keep away from curtains and other combustible materials WARNING RISK OF FIRE INJURY TO PERSONS Keep away from combustibles Unplug to change lamp Do not touch lamp WARNING RISK OF FIRE Do not place lamp where the overhead surface is closer than 0 2m to the light source n Aurora Light Source Range IMPORTANT SAFETY INFORMATION INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted Lamp is HOT WARNING To reduce the risk of FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Unplug and allow to cool before replacing lamp Lamp gets HOT quickly Only contact plug when turning on Do not touch hot lens guard or enclosure Do not remain in light if skin feels warm Do not look directly at lighted lamp Keep lamp away from materials that may burn Use only with the correct lamp wattage as detailed on the serial label Failure to adhere to this will cause damage to the unit 8 Do not touch the lamp at any time Use a soft cloth Oil from skin may damage lamp 9 Do not operate product with missing or damaged guard lamp containment barrier lens or fibre optic harness 10 WARNING Lamp types are matched to the ballast and different wattages types cannot be used NOOO PS G
8. light source and it will start up automatically Light will be output from the port connector and out through the fibre harness Power cable If no light is produced please consult the TROUBLESHOOTING section in this manual On models with the optional dimmer control the light output intensity can be varied by turning the dimmer control knob COLOURWHEEL TWINKLE WHEEL CONTROL Decorative models of the Aurora are available with a number of different colourwheel control options The control system available will depend on the exact model specified Continuous rotation the wheel rotates continuously and cannot be stopped White light only output is available by removing the wheel as detailed on page 8 of this manual Separate feed the wheel is controlled by a secondary mains electrical feed It can be started and stopped on any colour by simply switching the power off Switch control the wheel can be started and stopped by using a switch built into the back of the unit Universal Fibre Optics e MAINTENANCE LAMP REPLACEMENT 1 Unplug unit from electrical supply and allow to cool 2 Remove the single screw A which secures the unit s lamp access hatch 3 Open the lamp access hatch and you will see the lamp sitting in its holder and attached to a ceramic plug B 4 With the lamp still attached to the ceramic plug pull it upwards and out of its holder C 5 Pull the ceramic plug from the end of the old
9. ort connector not plugged in correctly Allow unit to cool for 5 to 10 min Unit is overheating utes and investigate reason for overheating Lamp going on amp off randomly Please complete troubleshooting procedures before returning unit to us for further investigation Aurora Light Source Range TECHNICAL SPECIFICATIONS Description 35W 42W 50W 75W 100W Port connector size 30mm 30mm Supply voltage Input power 240VAC ua 40 8VA 69 6VA 91 2VA 127 2VA Running current 240VAC 0 14A 0 17A 0 29A 0 38A 0 53A a Tungsten Tungsten Tungsten Tungsten Tungsten PE halogen halogen halogen halogen halogen White light White light White light White light White light 261x142x105mm 261x142x105mm 261x142x105mm 261x142x105mm 261x142x105mm Decorative Decorative Decorative Decorative Decorative 261x142x119mm 261x142x119mm 261x142x119mm 261x142x119mm 261x142x119mm Weight White light 1 9kg White light 1 9kg White light 1 9kg White light 1 9kg White light 1 9kg 8 Decorative 2 1kg Decorative 2 1kg Decorative 2 1kg Decorative 2 1kg Decorative 2 1kg Universal Fibre Optics MAINTENANCE RECORD Please note that a record of all maintenance MUST be kept in the table below indicating what maintenance was undertaken and when This must be DATED for warranty purposes Maintenance Undertaken n Aurora Light Source Range Notes Universal Fibre Optics 12 Notes n Aurora Light Source Range
10. s provided overleaf for the purposes of recording ALL maintenance undertaken on the lightsource and MUST be filled in accordingly Universal Fibre Optics 8 CLEANING THE UNIT Disconnect unit from power supply and allow to cool before attempting any cleaning of the unit A visual check of the unit should be completed every 12 months However cleaning should take place as and when required The body of the unit can be cleaned with a soft damp cloth do not use any abrasives on the unit The fans and vents should be kept clear by periodically blowing them out with compressed air Glass filter to be cleaned with soap and water then dried TROUBLESHOOTING Problem Probable cause s Remedy Unit is completely dead Lamp Check and replace fuse and LED power indicator are not eege Check that power is switched on illuminated H and power supply is plugged in Replace lamp Allow unit to cool for 5 to 10 min Thermal switch activated utes and investigate reason for overheating LED power indicator amp fan are on but no light is output Check plug connection ensure lamp is properly seated in its holder and the pins are fully mated Lamp needs replacing Replace lamp Unit needs cleaning Clean glass lens Ensure power supply is 240VAC Incorrect power supply 50H Poor light output Ensure fibre port connector is plugged in correctly and that the screw is tightened up properly Lamp wires are not connected Fibre p