Home
User Manual of M-F100 Fingerprint Access Control Device
Contents
1. 30 seconds Biet IN iAd ken iii PN Mode one key 1 FP amp PW For fingerprint and password validation no sequence PO Pianta aaa niaii BRENN Register a new user s fingerprint or card and register cards by batch total 500 ID ae se 2 4 Set standby mode default closed amp Note numbers from 1 99999 pai els due ee ibe seen aie ai if 3 You can edit mode by power on all lights and validation modes are closed 1 When input 3 digits for unlock time device auto confirm you need press Access Control Peer a a A a eye Meer when enter to standby You can activate by press any one key except for to confirm if less than 3 digits How tondd anew user than 254 amp Note the set door magnetic mode is the basis for door magnetic alarm door belb e 7 2 1 Revise 8 groups PINs for door passing default all are 000 000 Exit when press key oor bell button 2 Input 255 for keeping opened larger than 255 is invalid data and need ore operation after input again 17 16 215 14 13 12 11 10
2. I Installation Method two 86 type bottom box Il Diagram of system LIT Door lock connection IV Connecting with other equipment User Manual of Access Control Device M F100 Method one on the wall B Device does not share same power supply with electrical lock installation i Below device operating steps are recommended l n sta atlo n U ser Ma nu al Step 1 remove the screws from Step 4 the equipment installed steps 5 the device fixed rear ae do not wiring electrified Note The working power supply of P San M F100 Rev 1 0 Step 1 remove the screws Step 2 remove the hanging panel Step 5 fix the device to the the bottom of the device by in 86 boxes have been fixed rear panel ote this device is DC12V working ramihe borona ihe a ne bar ecveroncpelly eee panel on the wall 1 The device support normally open and normally closed you a current of the device is 500mA l Installed the device and power on device by screwdriver Door Lock Magnetic Exit Button could realize by connecting different port The door is open when f the standby current of the device EA Validate the manger s passwords and revise electrify and closed when power off should use port NO On the is 500mA the device could work manager s passwords register users and authentication contrary use port NC after being connected the registrate and validate fingerprints card and password 2 To avoid the impact from backward voltage generated by Pl
3. Note amp Note Manager s initial password is 123456 and has total 3 groups 2 6 Set alarm When set open for this function tamper will trigger alarm A Caution once touch the alarm the buzzer of the device alarm first after P and pas las green light flashes j ae EEEren ST a bases L When log in the quantity of total cards device aum auto if the number is 3 digits After user validates those initial passwords all the passwords z a Peng ae Input manager s ai Presskey 7 n 30 seconds switch to alarm device to send out alarm signal To stop the ies sighs aia ekeen rhe node sere caengunas ae a see A a 5 D ee ee el tees ive fet fash anda tong a X Set tamper proof ce a nd m k alarm need proceed validation and pass the validation an i red light flashes and lvs 2 Before processing cards registration by batch all the users in the device must be clear ans yx How to revise manger s initial password X Set alarm delay for door magnetic 3 long beeps out And the card numbers must be series numbers Xr Set main switch for alarm default open This equipment is main switch of alarm function when it s ON wrong pressing alarm tamper alarm door magnetic alarm can send alarm normally After switch to OFF can not send any alarm A Attention When ID 00001 is empty no used yet could proceed cards registration by batch After registration operating previous all users will be deleted Exit auto exit after amp N
4. ote 1 When use O for new password setup after entering one group Jr How to delete all users eNom for changing password this new password will be closed and this new l amp Note After device is set up standby mode and enter to this mode LED key light fingerprint light are all off This mode default to closed Press key 1 green light flashes yy Set delay for door magnetic default 5 seconds 1 When register a new user ID number will auto Increase After register successfully ae eee ee een Y ar along Delay for door magnetic is delay to exam the door magnetic after the door password could not be used for door opening ell eerie E cet on eens eae Change successfully opened After door is opened device will exam the door magnetic auto the 2 5 Set door magnetic mode Default no 2 After revising one group password successfully input next group k Tee ae eee baa E cere tenet arene basal green light fash and device will alarm if the magnetic status does not match door magnetic mode Door magnetic modes are normal open normal closed no door magnetic number which need to be revised as well device will enter next group After setup flash the green light you can register again the registered information normal open is door magnetic keep opening normal closed is door magnetic directly for revising password nee a i Cy E re ree keep closed no door magnetic is device does not detect door magnetic amp N
5. ote Details explanation for the validation mode as follows celia aaa cata 5 P l User Management 2 2 Set time for unlock default as 5 seconds Input managers e z Validation mode Mode Explanation A t d h fi t man r 2 rd 1 1 Manager operation aneri vv Set wrong pressing for alarm default open ee Mode one key 1 PW For password validation only Yr How to add users by batch Wh a eau ae o i i ia a i tihedas 4 In order to safeguard the data security user must validate the manager When set open will send out alarm signal when validate failed 3 times oane pas green light flashes green light flashes sae a porne epa Moda one key 2 1 RE Bor care velidatowenly amp Note eee ea fe ee a re a e pi a s password before operating the device and can not proceed manager s validation within 20 seconds validation andialong bees and a long beep no door magnetic Mode one key 3 FP For fingerprint validation only Press 9 to auto confirm invalid when press other number and will exit after red light air eyo es Ete sO G0 econ a aah pai backs 3 How to validate manager s password 7 Mode one key 41 FP PW RF Partingamrnicor password Gr cara validation Fishes O bees then all manager s password revert to initial passwords there is a long beep prompt pion ihe p press kev LO Mode one key 5 RF amp PW For card and fingerprint validation no sequence l when take apart the device after
6. us n Minus of the power supply 3 Set parameters for device includes to revise 8 passwords electrical lock during it s being opened or closed when process z to 12V and GND for pein PA for m verifying PIN static mode door wy wiring access control system application you need connect a diode sensor mode alarm and so on a with model 1N4007 with the electrical lock in parallel device Functional Contents of the device Door bell attaches the diode pay attention to Plus n Minus in order to j 1 User Management release the backward voltage gP 1 1 Manager operation X How to validate manager s password A Device and electrical lock share same power supply X How to revise manger s initial password Step 3 put the back cover on Step 4 install the device on the Step 2 remove the hanging panel Step 3 install the device on Risen BL X How to do when forget manager s password the wall and aim the holes on fixed back cover from the device back cover of the fixed 86 type Note the situation of device and electrical lock share the same power 1 2 How to add new users the wall exactly and fix the bottom box on wall Introduction for the access control system Mores ie siao supply are 1 gt UnLock 12V 2 gt 1 Lock gt 1 3 gt Short distance between device V X How to add a new user and electrical lock f X How to add users by batch back cover on the wall by screws device and electrical lock D Door lock after device validate the staff device outp
7. ut door share the same power supply 1 3 User validation control signal then door open are 1 gt UnLock 12V 25 B Device does not share same power supply with electrical lock 1 4 Delete user Magnetic door detector magnetic detect the on off status 1 Lock gt 1 3 gt Short distance Note l X How to delete users automatically when the door is opened accidently and is closed between device and The situation that device does not share the same power supply with X How to delete all users electrical lock are 1 gt ULock 12V and 1 Lock 01A 2 gt UlockK12V 3 gt Long distance between device and electrical lock 1 defaulted as the output electricity from device UnLock defaulted as the working voltage of the electrical lock ILock defaulted as the working current of the electrical lock 2 Access Control 2 1 Revise 8 groups PINs for door passing 2 2 Set time for unlock 2 3 Set validation mode 2 4 Set standby mode 2 5 Set door magnetic mode electrical lock well it alarms Alarm when access control is collected fingerprint illegal alarm output warning signal Exit button could connect external exit button so that could open door indoor G Alarm could connect external alarm Note the device only could be connected the alarm with output less than and equal to DC12V I 3 4 6 ae 8 Jrset tamper proof default open Doa 2 6 Set alarm acai aaa 2 3 Set validation mode default mode 4 aes amp
Download Pdf Manuals
Related Search
Related Contents
Samsung SL-M3820D User Manual Kurzanleitung EDMI3102 (pdf, 1MB, deutsch) Calligaris SEATTLE Modecom MC-WM4 to the Fire Tiger Tooth Blade Safety Instruction Manual. Situation de crise PSST...QUIET...OUR PRINTERS Comfortcook Bedienungsanleitung der Graef »CM 800 Rapport d`observations définitives et ses réponses COMMUNE DE Copyright © All rights reserved.
Failed to retrieve file